Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Accumulation of trace elements in soil and fauna within a site historically contaminated with coal combustion residues

Legacy contaminants tied to energy production are a worldwide concern. Coal combustion residues (CCRs) contain high concentrations of potentially toxic trace elements such as arsenic (As), mercury (Hg), and selenium (Se), which can persist for decades after initial contamination. Coal combustion residue disposal methods, including aquatic settling basins and landfills, can facilitate environmental exposure through intentional and accidental releases. Wildlife exposed to CCRs can experience numerous deleterious effects, such as on development, reproduction, and survival. In the current study, we quantified and compared concentrations of As, Hg, Se, and strontium (Sr) within soils and target fauna (three vertebrate and three invertebrate taxa) from a CCR-contaminated site and a reference site within the U.S. Department of Energy’s Savannah River Site, South Carolina, United States. Our objectives were to (1) compare current concentrations of tested elements in soil and resident fauna to levels from our reference site, (2) assess natural attenuation of elements in soils by comparing current concentrations to historic levels, and (3) evaluate the biomagnification potential of the elements measured via body burden and trophic position correlations among fauna. Here, element concentrations were higher in contaminated soils than reference soils; however, concentrations in 2022 were unchanged from concentrations measured in 2003, suggesting no natural attenuation of tested elements. Additionally, target fauna had elevated As, Se, and Sr levels in comparison to reference samples. A positive correlation was observed in southern toads between Sr concentrations and trophic position, as assessed by nitrogen stable isotope ratios, suggesting potential for biomagnification of Sr within our study system. Collectively, our results demonstrate that legacy contaminants are still present and bioaccumulate in a diversity of taxa in a CCR-contaminated site that has not received effluents in more than 50 years, suggesting monitoring programs in CCR-contaminated sites should be maintained long term in the absence of remediation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A semblance measure for model comparison

Algorithmic and computational advances have made it possible that geophysical survey and earth model design can be aided by many systematic trial inverse-modelling runs with synthetic data. Such may, for example, come up in machine-learning approaches. Automated image appraisal pertaining to such applications will involve common statistical tests for goodness-of-data fit as a primary evaluation method. However, solution non-uniqueness may render multiple images equivalent in terms of their data fit, requiring secondary categorizers. A logical choice for classifying synthetic-imaging results quantifies the goodness of model fit where a known reference model replaces the observational input. The task of model intercomparison in terms of measuring the resemblance to the reference model poses challenges to common distance-based metrics like root mean square error and mean absolute error. First, distance-based metrics can introduce spurious contributions when smooth models with fuzzy target contours are to be compared against a sharp reference. Second, large differences due to parameter-estimation overshoots can dominate distance metrics. Here, we propose a remedy that is referred to as semblance and is based on the idea of logistic functions, where a binary-dependent variable adds non-zero or zero accumulation terms for the, respectively, passing or failing of preset target thresholds. This classifying approach is amenable to an objective where model feature recognition is primary. Numerical comparisons to distance-based metrics provide evidence for the advantages of the semblance in view of this objective. Geophysical imaging in conjunction with machine-learning is seen as a benefitting upcoming application area.

58 GEOSCIENCES↗

Detailed space–time variations of the seismic response of the shallow crust to small earthquakes from analysis of dense array data

SUMMARY We compute high-resolution space–time variations of subsurface seismic properties from autocorrelation functions (ACF’s) of noise and local earthquakes, recorded by the Sage Brush Flat dense array deployed around the Clark branch of the San Jacinto fault. The resolved temporal changes are referred to as apparent velocity changes because they reflect both nonlinear response and variations of material properties such as cracking and damage. Apparent velocity changes are estimated at four frequency bands (10–15, 10–20, 15–30 and 20–40 Hz) for two local earthquake data sets. In one analysis, ACF’s from P- and S-wave windows of 31 small events with magnitudes below 3.1 are used to compute the apparent velocity variations with respect to the mean ACF of each phase, and we also use the mean ACF of noise data as reference to estimate the changes. In a further analysis, the temporal evolution of properties is computed using moving time windows in continuous waveform over one-hour long data with noise and earthquake signals. The apparent velocity changes and recovery times are frequency dependent and present a strong spatial variability across the array. The resolved changes are larger and recovery time shorter with data associated with higher frequencies. At frequencies larger than 15 Hz, and using the mean ACF of noise data as a reference, the apparent average velocity changes across the array during the passage of the P and S waves from the small local events are 2.5 per cent and 6 per cent, respectively. The apparent velocity changes decrease by one order of magnitude when the earthquake data are used as a reference. The relatively large changes in response to very low ground motion have important implications on nonlinear processes involving degradation and healing of the subsurface material during common earthquake shaking.

Geochemistry & Geophysics↗

Repulsion and total reflection with mismatched three-wave interaction of noncollinear optical beams in quadratic media

The phenomenon of the total reflection of a weak signal beam from a high-power reference beam due to noncollinear mismatched parametric interaction in a quadratic medium is demonstrated. In a planar geometry the conditions of the signal beam reflection from the optical inhomogeneity induced by the reference beam are found. The analytical expression for the critical value of the signal beam tilt is obtained, and it is shown that total reflection occurs if the initial tilt is less than the critical value. The influence of the walk-off and the reference beam focusing on interaction dynamics are discussed. It is shown that in a bulk medium the beam reflection turns into scattering by an induced inhomogeneity. If reflection conditions are fulfilled, the cylindrical reference beam acts as a convex mirror and lunate distortions of the reflected beam profile occur.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Configuration mixing within the energy density functional formalism: Removing spurious contributions from nondiagonal energy kernels

Multi reference calculations along the lines of the generator coordinate method or the restoration of broken symmetries within the nuclear energy density functional (EDF) framework are becoming a standard tool in nuclear structure physics. These calculations rely on the extension of a single-reference energy functional, of the Gogny or the Skyrme types, to nondiagonal energy kernels. There is no rigorous constructive framework for this extension so far. The commonly accepted way proceeds by formal analogy with the expressions obtained when applying the generalized Wick theorem to the nondiagonal matrix element of a Hamilton operator between two product states. It is pointed out that this procedure is ill defined when extended to EDF calculations as the generalized Wick theorem is taken outside of its range of applicability. In particular, such a procedure is responsible for the appearance of spurious divergences and steps in multi reference EDF energies, as was recently observed in calculations restoring particle number or angular momentum. In the present work, we give a formal analysis of the origin of this problem for calculations with and without pairing, i.e., constructing the density matrices from either Slater determinants or quasiparticle vacua. We propose a method to regularize nondiagonal energy kernels such that divergences and steps are removed from multi reference EDF energies. Such a removal is a priori quasiparticle-basis dependent. A special feature of the method we use to proceed to the actual regularization is that it singles out one basis among all possible ones. The regularization method is applicable to calculations based on any symmetry restoration or generator coordinate but is limited to EDFs depending only on integer powers of the normal and anomalous density matrices. Eventually, the method is formally illustrated for particle-number restoration and is specified to configuration mixing calculations based on Slater determinants.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Particle-number restoration within the energy density functional formalism

We give a detailed analysis of the origin of spurious divergences and finite steps that have been recently identified in particle-number-restoration calculations within the nuclear energy density functional framework. We isolate two distinct levels of spurious contributions to the energy. The first one is encoded in the definition of the basic energy density functional itself, whereas the second one relates to the canonical procedure followed to extend the use of the energy density functional to multi-reference calculations. The first level of spuriosity relates to the long-known self-interaction problem and to the newly discussed self-pairing interaction process that might appear when describing paired systems with energy functional methods using auxiliary reference states of Bogoliubov or BCS type. A minimal correction to the second level of spuriosity to the multi-reference nuclear energy density functional proposed in [D. Lacroix, T. Duguet, and M. Bender, Phys. Rev. C 79, 044318 (2009)] is shown to remove completely the anomalies encountered in particle-number-restored calculations. In particular, it restores sum rules over (positive) particle numbers that are to be fulfilled by the particle-number-restored formalism. The correction is found to be on the order of several hundreds of keVs up to about 1 MeV in realistic calculations, which is small compared to the total binding energy but often accounts for a substantial percentage of the energy gain from particle-number restoration and is on the same energy scale as the excitations one addresses with multi-reference energy density functional methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nucleon-gold collisions at 200A GeV using tagged d + Au interactions in the PHOBOS detector

Forward calorimetry in the PHOBOS detector has been used to study charged hadron production in d+Au, p+Au, and n+Au collisions at √s NN =200GeV. The forward proton calorimeter detectors are described and a procedure for determining collision centrality with these detectors is detailed. The deposition of energy by deuteron spectator nucleons in the forward calorimeters is used to identify p+Au and n+Au collisions in the data. A weighted combination of the yield of p+Au and n+Au is constructed to build a reference for Au+Au collisions that better matches the isospin composition of the gold nucleus. The p T and centrality dependence of the yield of this improved reference system is found to match that of d+Au. The shape of the charged-particle transverse momentum distribution is observed to extrapolate smoothly from p+p¯ to central d+Au as a function of the charged-particle pseudorapidity density. The asymmetry of positively and negatively charged hadron production in p+Au is compared to that of n+Au. No significant asymmetry is observed at midrapidity. In conclusion, these studies augment recent results from experiments at the CERN Large Hadron Collider and BNL Relativistic Heavy Ion Collider facilities to give a more complete description of particle production in p+A and d+A collisions, essential for the understanding the medium produced in high-energy nucleus-nucleus collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Universal Controller for Grid-Forming Inverters in Microgrid during Islanding for Low Transient Current

This paper presents a universal controller to reduce the transient current during islanding of microgrid. In the proposed universal controller, two sets of semi-parallel paths are formed, where one set produces voltage and phase-angle references for the grid-following (GFL) mode, and the other set produces the voltage and phase-angle references for the grid-forming (GFM) mode of operation for the inverters. Herein, the controller enables an inverter to universally operate in GFL and GFM mode, whereas, only one set of voltage and phase-angle reference is engaged for PWM signal generation. When the microgrid is disconnected from the grid, the universal controller switches the voltage and phase-angle references from GFL to GFM mode. The proposed controller ensures lower transient current by keeping the two sets of semi-parallel paths synchronized throughout the operation of the inverter and enabling seamless transition between the modes. The proposed controller is verified through hardware experiments under different scenarios in a laboratory scale microgrid for inverters transitioning from GFL to GFM mode after islanding.

Sadeque, Fahmid↗

Leveraging Multiple Connected Traffic Light Signals in an Energy-Efficient Speed Planner

Connecting automated vehicles to traffic lights can lead to significant energy savings by enabling them to pass through intersections in an energy-efficient way without unnecessary stops. A cellular-based communication system connecting multiple traffic lights can help realize the full potential of energy-efficient driving at intersections. Thus, we propose a hierarchical speed planner that can leverage information from multiple connected traffic lights. The proposed speed planner consists of two modules: a green window selector and a reference trajectory generator. The green window selector, based on Dijkstra’s algorithm, finds a series of "green windows" for connected traffic lights that builds an energy-optimal path for vehicles to follow. The reference trajectory generator finds optimal entering times, based on the selected green window at each intersection, and then computes reference trajectories. Deriving and using analytical optimal entering speeds as a function of entering times allows us to guarantee the computational simplicity suitable for real-time implementation. We also demonstrate how to balance energy and traffic flow perspectives in the reference trajectory generator. Lastly, a high-fidelity simulation framework is used to evaluate the proposed speed planner and quantify the extent to which it can save energy in various real-world urban route scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Virtual Chunks: On Supporting Efficient Accesses to Compressed Scientific Data

Data compression could ameliorate the I/O pressure of data-intensive scientific applications. Unfortunately, the conventional wisdom of naively applying data compression to the file or block brings the dilemma between efficient random accesses and high compression ratios. File-level compression barely supports efficient random accesses to the compressed data: any retrieval request need trigger the decompression from the beginning of the compressed file. Block-level compression provides flexible random accesses to the compressed blocks, but introduces extra overhead when applying the compressor to each and every block that results in a degraded overall compression ratio. This paper extends our prior work that introduces virtual chunks offering efficient random accesses to the compressed scientific data without sacrificing the compression ratio. Virtual chunks are logical blocks pointed at by appended references without breaking the physical continuity of the file content. These references allow the decompression to start from an arbitrary position (efficient random accesses), while no per-block overhead is introduced because the file’s physical entirety is retained (high compression ratio). One limitation of virtual chunk is it only supports static references. This paper presents the algorithms, analysis, and evaluations of dynamic virtual chunks to deal with the cases where the references are updated dynamically.

I/O compression performance optimization↗

System Evaluation and Economic Analysis of a Nuclear Reactor Powered High-Temperature Electrolysis Hydrogen-Production Plant

A reference design for a commercial-scale high-temperature electrolysis (HTE) plant for hydrogen production was developed to provide a basis for comparing the HTE concept with other hydrogen production concepts. The reference plant design is driven by a high-temperature helium-cooled nuclear reactor coupled to a direct Brayton power cycle. The reference design reactor power is 600 MWt, with a primary system pressure of 7.0 MPa, and reactor inlet and outlet fluid temperatures of 540°C and 900°C, respectively. The electrolysis unit used to produce hydrogen includes 4,009,177 cells with a per-cell active area of 225 cm2. The optimized design for the reference hydrogen production plant operates at a system pressure of 5.0 MPa, and utilizes an air-sweep system to remove the excess oxygen that is evolved on the anode (oxygen) side of the electrolyzer. The inlet air for the air-sweep system is compressed to the system operating pressure of 5.0 MPa in a four-stage compressor with intercooling. The alternating current (AC) to direct current (DC) conversion efficiency is 96%. The overall system thermal-to-hydrogen production efficiency (based on the lower heating value of the produced hydrogen) is 47.1% at a hydrogen production rate of 2.356 kg/s. An economic analysis of this plant was performed using the standardized H2A Analysis Methodology developed by the Department of Energy (DOE) Hydrogen Program, and using realistic financial and cost estimating assumptions. The results of the economic analysis demonstrated that the HTE hydrogen production plant driven by a high-temperature helium-cooled nuclear power plant can deliver hydrogen at a competitive cost. A cost of $3.23/kg of hydrogen was calculated assuming an internal rate of return of 10%.

08 HYDROGEN↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Raman Database Considerations for Near-Infrared Systems

For Raman spectroscopy the ability to detect is often limited by the existence and quality of the reference library to which field spectra are compared. Developing such databases is often labor- and resource-intensive; typically the generated data are not transferred to other instruments. Still other considerations may exist for comparing data at visible and ultraviolet excitation wavelengths such as resonance enhancement. However, for the common near-infrared wavelengths of 785, 830, 960, 1047 and 1064 nm where this is normally of a lesser concern, it is logical to consider whether data can be ported from one spectrometer to another so as to obviate the expensive and time-consuming process of generating reference data for each system. The present experiment generated a list of 125 chemical and common substances and formed a database from their corresponding 1064 nm spectra. The same molecules were then measured using a 785 nm system the new spectra were treated as “unknowns” and compared to the 1064 nm database using a commercial search algorithm. We found that at least 108 of the 125 spectra recorded at 785 nm were correctly identified using the search algorithm. For the few that were incorrectly identified, in most cases the spectra were extremely similar or the 785 nm signal was degraded due to fluorescence, as would occur regardless of reference data. Our results indicate that if the spectrometers are properly calibrated on both their wavelength and intensity axes, “foreign” data recorded at a different NIR wavelength can be successfully used as reference libraries

Kunkel, Brenda M↗

The delta envelope: A technique for dose distribution comparison

The {gamma} index is a tool that compares a dose distribution with a reference distribution by combining dose-difference and distance-to-agreement criteria. It has been widely used for ten years despite its high computational cost. This cost is due to both a search process for each reference point and the necessity to remove overestimations caused by the discrete nature of dose grids. The method proposed in this paper is much faster since it avoids both these problems. It consists in computing the {delta} envelope formed by the {gamma} ellipsoids around the points of the reference distribution. This {delta} envelope provides dose-difference tolerances that are then used to create new indices, called the {delta} indices, that provide useful information to interpret the deviations. Applied to both 1D and 2D test cases and compared to the {gamma} index, the {delta} indices proved to be very accurate and intuitive. Their computational efficiency was evaluated on a 3D case: the {delta} envelope can be computed in 8 s on a 250x250x50 grid. Moreover it can be precomputed if the reference dose is known in advance. Then the {delta} indices are obtained in less than 2 s.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In vivo verification of proton beam path by using post-treatment PET/CT imaging

Purpose: The purpose of this study is to establish the in vivo verification of proton beam path by using proton-activated positron emission distributions. Methods: A total of 50 PET/CT imaging studies were performed on ten prostate cancer patients immediately after daily proton therapy treatment through a single lateral portal. The PET/CT and planning CT were registered by matching the pelvic bones, and the beam path of delivered protons was defined in vivo by the positron emission distribution seen only within the pelvic bones, referred to as the PET-defined beam path. Because of the patient position correction at each fraction, the marker-defined beam path, determined by the centroid of implanted markers seen in the post-treatment (post-Tx) CT, is used for the planned beam path. The angular variation and discordance between the PET- and marker-defined paths were derived to investigate the intrafraction prostate motion. For studies with large discordance, the relative location between the centroid and pelvic bones seen in the post-Tx CT was examined. The PET/CT studies are categorized for distinguishing the prostate motion that occurred before or after beam delivery. The post-PET CT was acquired after PET imaging to investigate prostate motion due to physiological changes during the extended PET acquisition. Results: The less than 2 deg. of angular variation indicates that the patient roll was minimal within the immobilization device. Thirty of the 50 studies with small discordance, referred as good cases, show a consistent alignment between the field edges and the positron emission distributions from the entrance to the distal edge. For those good cases, average displacements are 0.6 and 1.3 mm along the anterior-posterior (D{sub AP}) and superior-inferior (D{sub SI}) directions, respectively, with 1.6 mm standard deviations in both directions. For the remaining 20 studies demonstrating a large discordance (more than 6 mm in either D{sub AP} or D{sub SI}), 13 studies, referred as motion-after-Tx cases, also show large misalignment between the field edge and the positron emission distribution in lipomatous tissues around the prostate. These motion-after-Tx cases correspond to patients with large changes in volume of rectal gas between the post-Tx and the post-PET CTs. The standard deviations for D{sub AP} and D{sub SI} are 5.0 and 3.0 mm, respectively, for these motion-after-Tx cases. The final seven studies, referred to as position-error cases, which had a large discordance but no misalignment, were found to have deviations of 4.6 and 3.6 mm in D{sub AP} and D{sub SI}, respectively. The position-error cases correspond to a large discrepancy on the relative location between the centroid and pelvic bones seen in post-Tx CT and recorded x-ray radiographs. Conclusions: Systematic analyses of proton-activated positron emission distributions provide patient-specific information on prostate motion ({sigma}{sub M}) and patient position variability ({Sigma}{sub p}) during daily proton beam delivery. The less than 2 mm of displacement variations in the good cases indicates that population-based values of {Sigma}{sub p} and {sigma}{sub M} used in margin algorithms for treatment planning at the authors' institution are valid for the majority of cases. However, a small fraction of PET/CT studies (approximately 14%) with {approx}4 mm displacement variations may require different margins. Such data are useful in establishing patient-specific planning target volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of a {sup 90}Sr/{sup 90}Y source for intra-ocular treatment of wet age-related macular degeneration

Purpose: The purpose of this study is to perform an extensive investigation of an approximately 2.5 mm long {sup 90}Sr/{sup 90}Y source designed for treating wet age-related macular degeneration. Methods: As part of this investigation, a NIST-traceable absorbed dose to water calibration technique was established, and a source deployment verification test was developed. The influence of treatment cannula construction tolerance on the measurements as well as the dose delivered to the patient was investigated using the Monte Carlo code MCNP5. Variation between production cannulae was quantified experimentally using a well-type ionization chamber, and additional measurements along with Monte Carlo calculations of the collimating insert used for source deployment verification were performed to validate the model. Results: Maximum variation in the integrated target dose was seen when the source was shifted laterally within the treatment cannula. For the well chamber measurements, the observed standard deviation in ionization current for a single source placed in different reference cannulae was {+-}0.3%, with a maximum observed range of less than {+-}0.5%. Clinical cannulae in the collimating insert showed an average of 17.8%{+-}0.4% of the reference signal when sources were fully deployed compared to 18.5% predicted by Monte Carlo calculations. This discrepancy has been attributed primarily to construction of the collimator since the collimation gap was observed to be approximately 0.025-0.075 mm smaller than specified. Construction tolerance of the well chamber insert as well as position tolerance of the cannula tip were both investigated, and their influence on the predicted signal was quantified. Additional measurements along with Monte Carlo based calculations of the collimating insert with polyethylene spacers added to the setup were performed to validate the Monte Carlo model. The shimmed Monte Carlo and measured data agree to within 1%, which is a magnitude difference of approximately 0.1% of the reference signal. Conclusions: This investigation confirms that the signal for an acceptably deployed source in the collimating insert is between 17.5% and 21.5% of the reference signal, as calculated using Monte Carlo models. Clinical cannulae for which the source deployment verification measurement falls outside the acceptable range should not be used to treat patients.

07 ISOTOPE AND RADIATION SOURCES↗

Reconstruction of 3D lung models from 2D planning data sets for Hodgkin's lymphoma patients using combined deformable image registration and navigator channels

Purpose: Late complications (cardiac toxicities, secondary lung, and breast cancer) remain a significant concern in the radiation treatment of Hodgkin's lymphoma (HL). To address this issue, predictive dose-risk models could potentially be used to estimate radiotherapy-related late toxicities. This study investigates the use of deformable image registration (DIR) and navigator channels (NCs) to reconstruct 3D lung models from 2D radiographic planning images, in order to retrospectively calculate the treatment dose exposure to HL patients treated with 2D planning, which are now experiencing late effects. Methods: Three-dimensional planning CT images of 52 current HL patients were acquired. 12 image sets were used to construct a male and a female population lung model. 23 ''Reference'' images were used to generate lung deformation adaptation templates, constructed by deforming the population model into each patient-specific lung geometry using a biomechanical-based DIR algorithm, MORFEUS. 17 ''Test'' patients were used to test the accuracy of the reconstruction technique by adapting existing templates using 2D digitally reconstructed radiographs. The adaptation process included three steps. First, a Reference patient was matched to a Test patient by thorax measurements. Second, four NCs (small regions of interest) were placed on the lung boundary to calculate 1D differences in lung edges. Third, the Reference lung model was adapted to the Test patient's lung using the 1D edge differences. The Reference-adapted Test model was then compared to the 3D lung contours of the actual Test patient by computing their percentage volume overlap (POL) and Dice coefficient. Results: The average percentage overlapping volumes and Dice coefficient expressed as a percentage between the adapted and actual Test models were found to be 89.2{+-}3.9% (Right lung=88.8%; Left lung=89.6%) and 89.3{+-}2.7% (Right=88.5%; Left=90.2%), respectively. Paired T-tests demonstrated that the volumetric reconstruction method made a statistically significant improvement to the population lung model shape (p<0.05). The error in the results were also comparable to the volume overlap difference observed between inhale and exhale lung volumes during free-breathing respiratory motion (POL:p=0.43; Dice:p=0.20), which implies that the accuracies of the reconstruction method are within breathing constraints and would not be the confining factor in estimating normal tissue dose exposure. Conclusions: The result findings show that the DIR-NC technique can achieve a high degree of reconstruction accuracy, and could be useful in approximating 3D dosimetric representations of historical 2D treatment. In turn, this could provide a better understanding of the biophysical relationship between dose-volume exposure and late term radiotherapy effects.

61 RADIATION PROTECTION AND DOSIMETRY↗