Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity analyses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

A generic scenario analysis of end-of-life plastic management: Chemical additives

Plastic growing demand and the increment in global plastics production have raised the number of spent plastics, out of which over 90% are either landfilled or incinerated. Both methods for handling spent plastics are susceptible to releasing toxic substances, damaging air, water, soil, organisms, and public health. Improvements to the existing infrastructure for plastics management are needed to limit chemical additive release and exposure resulting from the end-of-life (EoL) stage. This article analyzes the current plastic waste management infrastructure and identifies chemical additive releases through a material flow analysis. Additionally, we performed a facility-level generic scenario analysis of the current U.S. EoL stage of plastic additives to track and estimate their potential migration, releases, and occupational exposure. Potential scenarios were analyzed through sensitivity analysis to examine the merit of increasing recycling rates, using chemical recycling, and implementing additive extraction post-recycling. Our analyses identified that the current state of plastic EoL management possesses high mass flow intensity toward incineration and landfilling. Although maximizing the plastic recycling rate is a reasonably straightforward goal for enhancing material circularity, the conventional mechanical recycling method requires improvement because major chemical additive release and contamination routes act as obstacles to achieving high-quality plastics for future reuse and should be mitigated through chemical recycling and additive extraction. In conclusion, the potential hazards and risks identified in this research create an opportunity to design a safer closed-loop plastic recycling infrastructure to handle additives strategically and support sustainable materials management efforts to transform the US plastic economy from linear to circular.

54 ENVIRONMENTAL SCIENCES↗

Precise Chemical Analyses of Planetary Surfaces

We identify the chemical elements and element ratios that should be analyzed to address many of the issues identified by the Committee on Planetary and Lunar Exploration (COMPLEX). We determined that most of these issues require two sensitive instruments to analyze the necessary complement of elements. In addition, it is useful in many cases to use one instrument to analyze the outermost planetary surface (e.g. to determine weathering effects), while a second is used to analyze a subsurface volume of material (e.g., to determine the composition of unaltered planetary surface material). This dual approach to chemical analyses will also facilitate the calibration of orbital and/or Earth-based spectral observations of the planetary body. We determined that in many cases the scientific issues defined by COMPLEX can only be fully addressed with combined packages of instruments that would supplement the chemical data with mineralogic or visual information.

Kring, David↗

New Measurements with Photons at the Tevatron

With the recent completion of Run II at the Fermilab Tevatron, the CDF and D0 experiments are publishing results based on challenging measurements that probe quantum chromodynamics (QCD) and are sensitive to next-to-leading-order (NLO) and next-to-next-to-leading-order (NNLO) effects and non-perturbative physics. A superior understanding of parton distribution functions and QCD backgrounds will improve the sensitivity of searches for new phenomena at the LHC and reduce uncertainties in a multitude of future measurements. We present three recent photon analyses from data collected at the Fermilab Tevatron: measurements of the direct photon pair production cross section at CDF and D0, measurements of azimuthal decorrelations and multiple parton interactions in {gamma} + 2 jet and {gamma} + 3 jet events at D0, and an observation of exclusive diphoton production at CDF.

43 PARTICLE ACCELERATORS↗

Additional Trials & Tribulations in Synthesizing a Sulfide Standard

Well-characterized sulfide reference materials that can serve as matrix-matched calibrants for in-situ trace element analyses via laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) remain elusive. Here, we describe the creation an in-house sulfide standard at NASA JSC that will be used to measure siderophile and chalcophile trace elements in low pressure experimental products, specifically pentlandite ([FeNi]9S8) and pyrrhotite ([FeNi]1-xS), as well as natural sulfides in terrestrial and meteoritic mineral assemblages. Recent methods in creating a homogenous sulfide standard include pressed pellets, synthesized chips, or fused glass [e.g. 1-3]. Other studies, however, have had success in forming homogenous FeS standards via synthesization methods [e.g. 4-6]. We present a variation of the method described in [4], in which we create a pyrrhotite standard doped with a variety of trace elements (Zn, As, Se, Mo, Ru, Rh, Pd, Sn, Sb, Te, W, Os, Ir, Pt, Au) at ~10-40 ppm and Cu at ~200 ppm. Sulfide compositions were constructed using Fe and Ni metal and elemental sulfur powders. Trace elements were added to elemental sulfur from Atomic Absorption Spectroscopy (AAS) elemental standards as either nitrate or chloride solutions to prevent oxidation of the metal powders. The dried sulfur mixture was mixed with Fe and Ni powders and mechanically mixed before two aliquots were placed in separate SiO2 tubes. Each tube was held under vacuum for ~30 minutes, sealed under vacuum, and then heated at 800C for 48 hours. Like [4], the synthesis products were composed of pourous sulfide crystals. Major element analyses of both experimental aliquots, collected using an Electron Probe Microanalyser (EPMA), yield indistinguishable major element compositions (uncertainties in 2SE & 2RSE[%]), with an average of 57.90  0.09 (0.16 %), 4.95  0.03 (0.55 %), and 39.70  0.14 (0.34 %), for Fe, Ni, and S, respectively. Trace element data were measured using a Photon Machines 193nm laser ablation system coupled to a Thermo-Scientific Element-XR ICP-MS. Spot sizes were limited to 50 μm due to the porous nature of the sulfide target material. Trace element abundances, normalized to Fe as an internal standard, were also found to be homogenous between the two aliquots, with weighted mean 2RSE (%) values of <3.0 for all trace elements. Synthesized products were re-powdered and absolute concentrations measured via solution ICP-MS. Although the sulfide appears to be homogenous, sintering experiments will be performed to more closely match the standard density to natural sulfides and minimize differences in ablation behavior. Improved density also allows for higher sensitivity (i.e. more compact target material) and larger spot sizes or traverses, as void space is eliminated. Additional major and trace element analyses on the products of the sintering experiments will be undertaken.

Jacob B Setera↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

Estimation of 3D Woven Design Sensitivities Using a Rapid Multiscale Analysis Technique

Highly-refined finite element models of three-dimension (3D) woven composite systems currently require excessive computational demands that limit their use in sensitivity analysis, uncertainty quantification, and optimization. An alternative analysis methodology was developed using the NASA Multiscale Analysis Tool (NASMAT) where multiscale models of a 3D woven composite (including inter-tow matrix voids and constituent failure) can be completed on a single central processing unit (CPU) on the order of ~30s. To develop inputs and validation data for the NASMAT model, coupon and acid-digesting testing and x-ray computed tomography were performed. The NASMAT inputs were parameterized using a set of 25 input variables and distributions. These inputs were randomly sampled to generate a total of 100,000 NASMAT analyses that could be used to understand the influence of different material and geometric properties on the warp and weft-direction stiffness and strength. These analyses (including pre/post-processing) were performed in less than eight hours on a 120 CPU cluster. The computational efficiency of the NASMAT model enabled a sensitivity analysis to be performed, and dominant input variables were able to be identified. Key results were consistent with theoretical and experimental observations for the specific 3D woven system studied in this work.

NASMAT↗

Estimation of 3D Woven Design Sensitivities Using a Rapid Multiscale Analysis Technique

Highly-refined finite element models of three-dimension (3D) woven composite systems currently require excessive computational demands that limit their use in sensitivity analysis, uncertainty quantification, and optimization. An alternative analysis methodology was developed using the NASA Multiscale Analysis Tool (NASMAT) where multiscale models of a 3D woven composite (including inter-tow matrix voids and constituent failure) can be completed on a single central processing unit(CPU)on the order of ~30 s. To develop inputs and validation data for the NASMAT model, coupon and acid-digesting testing and x-ray computed tomography were performed. The NASMAT inputs were parameterized using a set of 25 input variables and distributions. These inputs were randomly sampled to generate a total of 100,000 NASMAT analyses that could be used to understand the influence of different material and geometric properties on the warp and weft-direction stiffness and strength. These analyses (including pre/post-processing) were performed in less than eight hours on a 120 CPU cluster. The computational efficiency of the NASMAT model enabled a sensitivity analysis to be performed, and dominant input variables were able to be identified. Key results were consistent with theoretical and experimental observations for the specific 3D woven system studied in this work.

NASMAT↗

Prospects for gravitational wave and ultra-light dark matter detection with binary resonances beyond the secular approximation

Precision observations of orbital systems have recently emerged as a promising new means of detecting gravitational waves and ultra-light dark matter, offering sensitivity in new regimes with significant discovery potential. These searches rely critically on precise modeling of the dynamical effects of these signals on the observed system; however, previous analyses have mainly only relied on the secularly-averaged part of the response. We introduce here a fundamentally different approach that allows for a fully time-resolved description of the effects of oscillatory metric perturbations on orbital dynamics. We find that gravitational waves and ultra-light dark matter can induce large oscillations in the orbital parameters of realistic binaries, enhancing the sensitivity to such signals by orders of magnitude compared to previous estimates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exosomes secreted by placental stem cells selectively inhibit growth of aggressive prostate cancer cells

Highlights: • Detailed characterization of exosomes secreted by human placental stem cells (PLSC{sup Exo}) . • Identified anti-cancer efficacy of PLSC{sup Exo} against aggressive prostate cancer cells. • Retinoic acid receptor/Liver x receptor pathway seems central to PLSC{sup Exo} biological effects. The current paradigm in the development of new cancer therapies is the ability to target tumor cells while avoiding harm to noncancerous cells. Furthermore, there is a need to develop novel therapeutic options against drug-resistant cancer cells. Herein, we characterized the placental-derived stem cell (PLSC) exosomes (PLSC{sup Exo}) and evaluated their anti-cancer efficacy in prostate cancer (PCa) cell lines. Nanoparticle tracking analyses revealed the size distribution (average size 131.4 ± 0.9 nm) and concentration of exosomes (5.23 × 10{sup 10}±1.99 × 10{sup 9} per ml) secreted by PLSC. PLSC{sup Exo} treatment strongly inhibited the viability of enzalutamide-sensitive and -resistant PCa cell lines (C4-2B, CWR-R1, and LNCaP cells). Interestingly, PLSC{sup Exo} treatment had no effect on the viability of a non-neoplastic human prostate cell line (PREC-1). Mass spectrometry (MS) analyses showed that PLSC{sup Exo} are loaded with 241 proteins and mainly with saturated fatty acids. Further, Ingenuity Pathway Analysis analyses of proteins loaded in PLSC{sup Exo} suggested the role of retinoic acid receptor/liver x receptor pathways in their biological effects. Together, these results suggest the novel selective anti-cancer effects of PLSC{sup Exo} against aggressive PCa cells.

60 APPLIED LIFE SCIENCES↗

Optical specification of time-to-passage: Observers' sensitivity to global tau

Despite its general mathematical formulation, most empirical work on the visual perception of tau (defined as a quantity divided by its temporal derivative) has focused on the case of direct approach, with tau defined as image angle/rate of expansion. Empirical investigators tend to generalize image size analyses to off-axis approaches. However, this generalization is inappropriate for all but a few classes of objects. After mathematically reestablishing the appropriate optical cues specifying time to passage for noncollision cases, we report a series of studies in which we examined observers' sensitivities to this information in both relative- and absolute-judgment paradigms. In general, we found observers' judgments to be accurate and robust.

Kaiser, Mary K.↗

Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.

Mora, Maria F.↗

A comparison of water vapor derived from GPS occultations and global weather analyses

Occultation measurements from the Global Positioning System (GPS) should improve upon this situation. Individual occultations yield profiles of specific humidity accurate to 0.2 to 0.5 g/kg providing sensitive measurements of lower and middle tropospheric water vapor with global coverage in a unique, all-weather, limb-viewing geometry with several hundred metres to a kilometre vertical resolution. The authors have derived water vapor profiles from June 21 to July 4, 1995

global↗

Mars Exploration Rovers Landing Dispersion Analysis

Landing dispersion estimates for the Mars Exploration Rover missions were key elements in the site targeting process and in the evaluation of landing risk. This paper addresses the process and results of the landing dispersion analyses performed for both Spirit and Opportunity. The several contributors to landing dispersions (navigation and atmospheric uncertainties, spacecraft modeling, winds, and margins) are discussed, as are the analysis tools used. JPL's MarsLS program, a MATLAB-based landing dispersion visualization and statistical analysis tool, was used to calculate the probability of landing within hazardous areas. By convolving this with the probability of landing within flight system limits (in-spec landing) for each hazard area, a single overall measure of landing risk was calculated for each landing ellipse. In-spec probability contours were also generated, allowing a more synoptic view of site risks, illustrating the sensitivity to changes in landing location, and quantifying the possible consequences of anomalies such as incomplete maneuvers. Data and products required to support these analyses are described, including the landing footprints calculated by NASA Langley's POST program and JPL's AEPL program, cartographically registered base maps and hazard maps, and flight system estimates of in-spec landing probabilities for each hazard terrain type. Various factors encountered during operations, including evolving navigation estimates and changing atmospheric models, are discussed and final landing points are compared with approach estimates.

Knocke, Philip C.↗

Mars Exploration Rovers landing dispersion analysis

Landing dispersion estimates for the Mars Exploration Rover missions were key elements in the site targeting process and in the evaluation of landing risk. This paper addresses the process and results of the landing dispersion analyses performed for both Spirit and Opportunity. The several contributors to landing dispersions (navigation and atmospheric uncertainties, spacecraft modeling, winds, and margins) are discussed, as are the analysis tools used. The JPL MarsLS program, a MATLAB-based landing dispersion visualization and statistical analysis tool, was used to calculate the probability of landing within hazardous areas. By convolving this with the probability of landing within flight system limits (in-spec landing) for each hazard area, a single overall measure of landing risk was calculated for each landing ellipse. In-spec probability contours were also generated, allowing a more synoptic view of site risks, illustrating the sensitivity to changes in landing location, and quantifying the possible consequences of anomalies such as incomplete maneuvers. Data and products required to support these analyses are described, including the landing footprints calculated by NASA Langley's POST program and the JPL AEPL program, cartographically registered base maps and hazard maps, and flight system estimates of in-spec landing probabilities for each hazard terrain type. Various factors encountered during operations, including evolving navigation estimates and changing atmospheric models, are discussed and final landing points are compared with approach estimates.

Desai, Prasun N.↗

Assessment of Critical Experiment Benchmark Applicability to a Large-Capacity HALEU Transportation Package Concept

This work presents an assessment of the applicability of existing benchmark critical experiments to the criticality safety code validation for a large-capacity high-assay low-enriched uranium (HALEU) transportation package concept. Numerous next-generation nuclear reactor designs require HALEU fuel, which is characterized by an enrichment between 5 and 20 wt% 235 U. The U.S. Department of Energy (DOE) has proposed to recover and downblend highly enriched uranium from DOE-owned used nuclear fuel to accelerate the demonstration of commercially viable microreactor technologies. One element of the infrastructure needed to demonstrate HALEU-fueled reactors is the ability to safely transport enriched product to be used for fuel fabrication. There is uncertainty as to whether existing critical benchmark experiment data are sufficient to support criticality safety code validation for HALEU transportation applications. The anticipated chemical form of the HALEU in the proposed transportation concept is UO 2 with 20 wt% 235 U/U. The concept uses a combination of an existing transportation packaging design and a novel basket design, including borated aluminum flux traps. The basket provides space for 18 reusable, stainless steel canisters that contain the HALEU. In 10 CFR 71, normal conditions of transport (NCTs) and hypothetical accident conditions (HACs) are defined for fissile material transportation packages. NCT and HAC KENO-VI models of the transportation package were developed using the Standardized Computer Analyses for Licensing Evaluation (SCALE) 6.2.3 computer code package, and optimum moderation conditions were determined using the SCALE SAMPLER sequence. The SCALE Tools for Sensitivity and Uncertainty Analysis Methodology Implementation (TSUNAMI) sequences were then used to compare the neutronic characteristics of 1584 International Criticality Safety Benchmark Evaluation Project benchmark critical experiments with the NCT and HAC HALEU transportation models. The TSUNAMI integral correlation coefficient c k was the criterion used to rank neutronic similarity. Thirty-four experiments were identified as similar (c k ≥ 0.9) to the NCT model, and 55 experiments were identified as similar to the HAC model. Hundreds of experiments were also identified as at least marginally similar (c k ≥ 0.8) to both models. The results indicate that additional critical experiments are unlikely to be needed to support HALEU transportation criticality safety analyses for package concepts similar to the concept package analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-T-578: Characterization of Vidar DosimetryPro Advantage RED Scanner with Application to SBRT and SRS QA

Purpose: To use Gafchromic EBT3 film to quantify key dosimetric characteristics of the Vidar DosimetryPro Advantage RED film scanner for use in SBRT/SRS QA, by analyzing scanner uniformity and dose sensitivity. Method: Gafchromic EBT3 film was used in this study. Films were irradiated using 6MV FFF and 10MV FFF beams from a Varian Edge linear accelerator, with setup of 100cm SAD at depth 5 cm. Nine doses were delivered per film, with calibration dose ranges of 1–10 Gy and 3–24 Gy for 6MV FFF, and 3–27 Gy for 10MV FFF. Films were scanned with the long side of the film parallel to the detector array. Dose calibration curves were fitted to a 3rd degree polynomial. The derivative of a calibration curve was taken to determine the scanner’s sensitivity per dose delivered (OD/Gy). Scanner non-uniformity was calculated in 2 dimensions by taking the mean of standard deviation in each row and column. Absolute dose SRS/SBRT Gamma analyses were performed with passing criteria of 3% and 1mm DTA. For comparison, Gamma analyses were also performed using an Epson Expression 10000 XL. Results: Uniformity for the Vidar scanner was 0.37% +/− 0.03% in the perpendicular to scan direction and 0.67% +/− 0.05% in the parallel to scan direction, with an overall uniformity of 0.52% +/− 0.03%. Epson red channel uniformity was 0.85% +/− 0.05% and 0.88% +/− 0.08% for the green channel. The Vidar average dose sensitivity from 1–10 Gy was 0.112 OD/Gy and 0.061 OD/Gy for 3–24 Gy. SBRT/SRS Gamma pass rates were 97.8 +/− 1.4 for Vidar and 97.5 +/− 1.4 for Epson. Conclusion: The Vidar scanner has 41% less non-uniformity compared to Epson XL10000 green channel. The dose sensitivity is 2–3 time greater for the Vidar scanner compared to the Epson in the SRS/SBRT dose range of 5–24 Gy.

60 APPLIED LIFE SCIENCES↗

Using block-copolymer nanolithography as a tool to sensitively evaluate variation in chemical dry etching rates of semiconductor materials with sub-5 nm resolution

Ion implantation is a robust and established method to customize the electronic properties of Si. However, fabricating doped, ultrafine semiconductor nanostructures can be challenging. Ion implantation has well-established effects on the dry etch rates of Si, which becomes increasingly consequential as the target dimension shrinks below a few tens of nanometers. While dry etching arrays of block copolymer-templated nanoscale holes (pitch = 37.5 nm, diameter ~25 nm) into p-type, n-type, and undoped Si, we observed that the lateral etch rate was notably larger for the n-type regions than p-type or undoped regions. By doing image analyses on high resolution electron micrographs of the nanostructured hole arrays, we were able to extract the porosity and average radii of the holes with subnanometer sensitivity and compare the relative etch rates between different doping conditions. We found that degenerately doped n-type silicon consistently etches between approximately 17% and 27% faster in the lateral direction than p-type Si, resulting in significantly larger porosity and, consequently, less mechanical stability. Here, we demonstrate that top-down dimensional analysis of a densely packed porous nanostructure is a robust method for assessing extremely small differences in the lateral, chemical etch rate of doped Si to a degree of sensitivity that was previously unachievable. The minute, dense-packed nature of block copolymer self-assembled nanostructures is shown to be ideal for this application. This proposed method could be useful for designing fabrication processes for heterogeneous nanostructures, as slight dry etch rate variations that may be within process tolerance at the micrometer-scale appear to have nontrivial consequences at the nanometer scale.

42 ENGINEERING↗

Observing Exoplanets with High Dispersion Coronagraphy. I. The Scientific Potential of Current and Next-generation Large Ground and Space Telescopes

Direct imaging of exoplanets presents a formidable technical challenge owing to the small angular separation and high contrast between exoplanets and their host stars. High Dispersion Coronagraphy (HDC) is a pathway to achieve unprecedented sensitivity to Earth-like planets in the habitable zone. Here, we present a framework to simulate HDC observations and data analyses. The goal of these simulations is to perform a detailed analysis of the trade-off between raw star light suppression and spectral resolution for various instrument configurations, target types, and science cases. We predict the performance of an HDC instrument at Keck observatory for characterizing directly imaged gas-giant planets in near-infrared bands. We also simulate HDC observations of an Earth-like planet using next-generation ground-based (TMT) and spaced-base telescopes (HabEx and LUVOIR). We conclude that ground-based ELTs are more suitable for HDC observations of an Earth-like planet than future space-based missions owing to the considerable difference in collecting area. For ground-based telescopes, HDC observations can detect an Earth-like planet in the habitable zone around an M-dwarf star at 10{sup −4} star light suppression level. Compared to the 10{sup −7} planet/star contrast, HDC relaxes the star light suppression requirement by a factor of 10{sup 3}. For space-based telescopes, detector noise will be a major limitation at spectral resolutions higher than 10{sup 4}. Considering detector noise and speckle chromatic noise, R = 400 (1600) is the optimal spectral resolutions for HabEx (LUVOIR). The corresponding star light suppression requirement to detect a planet with planet/star contrast = 6.1×10{sup −11} is relaxed by a factor of 10 (100) for HabEx (LUVOIR).

79 ASTRONOMY AND ASTROPHYSICS↗