Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Spectro-Microscopy Studies of Atmospheric Particles

Our project investigated composition and physical properties of individual atmospheric particles collected in field campaigns organized by the DOE Atmospheric Systems Research and Atmospheric Radiation Measurement (ASR/ARM) programs, such as the Green Ocean Amazon (GoAmazon, 2014/5), the Holistic Interactions of Shallow Clouds, Aerosols, and Land-Ecosystems (HI-SCALE, 2016/7), the Aerosol and Cloud Experiment in the Eastern North Atlantic (ACE-ENA, 2017/8), the Aerosol–Ice Formation Closure Pilot Study (AEROICESTUDY, 2019) and in additional small-scale supporting field experiments focused on the investigation of the light-absorbing (aka brown carbon) atmospheric particles. In these studies, we investigated the contribution of natural and anthropogenic sources to populations of atmospheric particles during representative atmospheric conditions; characterized particle composition and evaluated their hygroscopic properties and propensity to act as cloud condensation nuclei (CCN) and ice nuclei (IN); correlated typical particle-type and mixing state characteristics with real-time measurements in the areas of studies. We used multi-modal spectro-microscopy techniques to examine elemental and molecular composition, mixing state, size, and higher order morphology for individual particles. Specifically, we used computer-controlled scanning electron microscopy and X-ray microanalysis for quantitative analysis of particle elemental composition, and we used transmission electron microscopy to provide additional information on the distribution of different components within individual particles (particle heterogeneity). We used synchrotron-based scanning transmission X-ray microscopy for quantitative description of the mixing state and molecular bonding of carbon in particles. The particle composition, mixing state, and morphology from analyzed periods was then combined with the real-time ARM measurements of aerosol size distribution, CCN concentration, hygroscopicity, and aerosol bulk composition. Combined together, results of our studies allowed us to assess the major particle sources (biogenic vs. anthropogenic, primary vs secondary) and gain insight into the atmospheric processing of aerosol particles resulting from condensation, coagulation, oxidative aging, and cloud processing. In collaboration with other scientists involved in field campaigns, we carried out statistical analysis of particle properties and their source-specific contributions to regional aerosol loading under representative air mass, meteorological, and cloud conditions.

scanning transmission X-ray microscopy↗

Understanding Subsurface Fracture Evolution Dynamics Using Time‐Lapse Full Waveform Inversion of Continuous Active‐Source Seismic Monitoring Data

Abstract Predicting the behavior, geometry, and flow properties of subsurface fractures remains a challenging problem. Seismic models that can characterize fractures usually suffer from low spatiotemporal resolution. Here, we develop a correlative double‐difference time‐lapse full waveform inversion of continuous active source seismic monitoring data for determining high‐spatiotemporal‐resolution time‐lapse V p models of in‐situ fracture evolution at a shallow contamination site in Wyoming, USA. Assisted by rock physics modeling, we find that (a) rapidly increasing pore pressure initializes and grows the fracture, increasing the porosity slightly (from ∼13.7% to ∼14.6%) in the tight clay formation, thus decreasing V p (∼50 m/s); (b) the fluid injection continues decreasing V p , likely through the introduction of gas bubbles in the injectate; and (c) final V p reductions reach over ∼150 m/s due to a posited ∼4.5% gas saturation. Our results demonstrate that high‐resolution V p changes are indicative of mechanical and fluid changes within the fracture zone during hydrofracturing.

58 GEOSCIENCES↗

Basin-Scale Structural Features Database

The Basin-Scale Structural Features database provides spatial datasets of faults, fractures, folds, and earthquakes compiled from public, authoritative sources (e.g., U.S. Geological Survey and State Geological Surveys) and aggregated into derivative forms to support subsurface assessments. Recognizing that characterizing basin-scale structural features requires interpreting data that are often ambiguous or lack key information, the source data were evaluated using a knowledge-data framework and geospatial fuzzy logic method (Justman et al., 2020) to represent both measured (observed) and predicted (inferred or potential) structural features as derivative datasets. This workflow employs conceptual models for known structural features and predicted structural features, incorporating geospatial data to estimate potential, even with limited data. The aim is to aid and support an understanding of basin-scale features and identify potential gaps in data and knowledge. As of 4/30/2025, the database includes resources for nine sedimentary basins: Appalachian, Denver, U.S. Gulf Coast, Illinois, Michigan, Permian, Sacramento, San Joquin and Williston. The database is organized by basin and then data category: 1) Faults, fractures, folds, 2) Earthquakes, 3) Topographic, 4) Structural contours and isopachs, 5) Geophysical, and 6) Structural feature density assessment maps.

basin scale↗

Managing Sn-Supply to Tune Surface Characteristics of Vapor-Diffusion Coating of Nb₃Sn

Nb₃Sn promises better RF performance (Q and E_{acc}) than niobium at any given temperature because of superior superconducting properties. Nb₃Sn-coated SRF cavities are now produced routinely by growing a few microns thick Nb₃Sn films inside Nb cavities via the tin vapor diffusion technique. Sn evaporation and consumption during the growth process notably affect the quality of the coating. Aiming at favorable surface characteristics that could enhance the RF performance, many coatings were produced by varying Sn sources and temperature profiles. Coupon samples were examined using different material characterization techniques, and a selected few sets of coating parameters were used to coat 1.3 GHz single-cell cavities for RF testing. The Sn supply’s careful tuning is essential to manage the microstructure, roughness, and overall surface characteristics of the coating. We summarize the material analysis of witness samples and discuss the performance of several Nb₃Sn-coated single-cell cavities linked to Sn-source characteristics and observed Sn consumption during the film growth process.

Pudasaini, U.↗

Managing Sn-supply to tune surface characteristics of vapor-diffusion coating of Nb3Sn

Nb₃Sn promises better RF performance (Q and E_{acc}) than niobium at any given temperature because of superior superconducting properties. Nb₃Sn-coated SRF cavities are now produced routinely by growing a few microns thick Nb₃Sn films inside Nb cavities via the tin vapor diffusion technique. Sn evaporation and consumption during the growth process notably affect the quality of the coating. Aiming at favorable surface characteristics that could enhance the RF performance, many coatings were produced by varying Sn sources and temperature profiles. Coupon samples were examined using different material characterization techniques, and a selected few sets of coating parameters were used to coat 1.3 GHz single-cell cavities for RF testing. The Sn supply’s careful tuning is essential to manage the microstructure, roughness, and overall surface characteristics of the coating. We summarize the material analysis of witness samples and discuss the performance of several Nb₃Sn-coated single-cell cavities linked to Sn-source characteristics and observed Sn consumption during the film growth process.

Pudasaini, U.↗

Worldwide measurements of radioxenon background near isotope production facilities, a nuclear power plant and at remote sites: the ‘‘EU/JA-II’’ Project

The Comprehensive Nuclear-Test-Ban Treaty (CTBT) specifies that radioxenon measurements should be performed at 40 or more stations worldwide within the International Monitoring System (IMS). Measuring radioxenon is one of the principle techniques to detect underground nuclear explosions. Specifically, presence and ratios of different radioxenon isotopes allows determining whether a detection event under consideration originated from a nuclear explosion or a civilian source. However, radioxenon monitoring on a global scale is a novel technology and the global civil background must be characterized sufficiently. This paper lays out a study, based on several unique measurement campaigns, of the worldwide concentrations and sources of verification relevant xenon isotopes. It complements the experience already gathered with radioxenon measurements within the CTBT IMS programme and focuses on locations in Belgium, Germany, Kuwait, Thailand and South Africa where very little information was available on ambient xenon levels or interesting sites offered opportunities to learn more about emissions from known sources. The findings corroborate the hypothesis that a few major radioxenon sources contribute in great part to the global radioxenon background. Additionally, the existence of independent sources of 131mXe (the daughter of 131I) has been demonstrated, which has some potential to bias the isotopic signature of signals from nuclear explosions.

Saey, P. R.J.↗

Milestone 1.2.15: Feasibility of In Situ Accelerated Aluminum Coupon Radiolysis by Synchrotron X-Rays

Extended dry storage of aluminum-clad spent nuclear fuel (ASNF) requires an assessment of the radiolytic generation of molecular hydrogen gas (H2) from the ASNF’s corrosion layers. H2 accumulation can potentially lead to storage canister embrittlement/rupture and the accumulation of flammable gas mixtures in accident scenarios. To date, computational models have been developed for the prediction of radiolytic H2 generation from samples exposed to lower absorbed dose regimes (up to ~3 MGy). However, greater accuracy is needed for higher absorbed doses (> 25 MGy) where the concentration of H2 ultimately reaches a steady-state. Data in this area is limited due to the amount of time taken (months) to accumulate such high gamma doses. Furthermore, a recent study observed radiation-induced damage to the surface of pre-corroded aluminum alloy coupons at high absorbed gamma doses. Despite this observation and its implications, there is currently no computational connection between the radiolytic formation of H2 and changes in the composition and morphology of the cladding’s corrosion layers with absorbed dose. To develop a better understanding of the processes and effects described above, the present study aimed to evaluate the feasibility of leveraging synchrotron x-ray capabilities for coupled accelerated irradiation and in situ surface characterization of ASNF alloys. To that end, National Synchrotron Light Source II (NSLS-II) beamtime was secured and a series of aluminum alloy 1100 (AA1100) wires, prepared under a variety of conditions, were interrogated using ex situ x-ray diffraction (XRD) and scanning electron microscopy (SEM) techniques at Idaho National Laboratory (INL) and ex situ and in situ XRD capabilities at the NSLS-II x-ray powder diffraction (XPD) beamline. Results indicated that performing synchrotron XRD using the available XPD beamline configuration can provide sufficient radiation dose but cannot discern changes in the composition and morphology of sample corrosion layers. Additionally, ex situ XRD and SEM data from Idaho National Laboratory (INL) indicated that the pre-corrosion of AA1100 wires did not generate an appreciably thick corrosion layer, as compared with previous aluminum coupon studies. These thinner surface corrosion layers were not sufficient for detection by both ex situ and in situ synchrotron XRD, specifically under consideration of the NSLS-II XPD beamline’s configuration primarily capturing information from the sample’s bulk material, i.e., aluminum metal. In summary, the use of the NSLS-II XPD beamline for promoting accelerated radiolysis and in situ surface characterization is not appropriate for this program’s goals.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterizing the Mechanical Response of the Saturn Accelerator

The Saturn Particle Accelerator is a hot X-ray source used by the NNSA for creating conditions similar to that of a nuclear weapon. When Saturn fires some of it's energy is released in the form of mechanical shock and vibration. This mechanical output has not been characterized or understood, making design of components and diagnostics more difficult. Thus it will be helpful to understand this mechanical shock. This poster presents the beginnings of a project to do just that.

Cuneo, Nicolas Francis [Sandia National Laboratori↗

Subsurface Energy Systems Mapping Inquiry Tool (MapIT)

The Subsurface Energy Systems Mapping Inquiry Tool (MapIT) is an online web mapping tool designed to help users discover available public-sourced data to facilitate data exploration for subsurface energy exploration and characterization efforts for resource identification (e.g. critical minerals, hydrocarbons, geothermal) as well as injection of geologic sequestration of carbon dioxide (e.g. enhanced oil recovery, saline storage, etc.). Modules within the tool curate data related to geology, faults, fractures, injection and confining zones, hydrologic information, groundwater, groundwater wells, geomechanical and petrophysical data, and geochemical data. User documentation on how to use the tool is also provided. Data have been collected from authoritative national, state, and local sources and made available in this tool. The data is also available as a data catalog and Esri Geodatabase at: https://edx.netl.doe.gov/dataset/mapit-database Disclaimer: There is no guarantee of completeness or appropriateness for individual user’s requirements. Use of this tool is solely at the discretion of the user. See full Federal Disclaimer for further information (https://netl.doe.gov/home/disclaimer). This project was funded by the United States Department of Energy, National Energy Technology Laboratory, in part, through a site support contract. Neither the United States Government nor any agency thereof, nor any of their employees, nor the support contractor, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. https://www.netl.doe.gov/home/disclaimer

Carbon Sequestration↗

Isotope ratio characteristics and sensitivity for uranium determinations using a liquid sampling-atmospheric pressure glow discharge ion source coupled to an Orbitrap mass analyzer

Abstract The continued development of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma as an ion source for diverse, elemental/isotopic analysis applications continues. To this end, characterization of the capabilities in performing precise and accurate isotope ratio (IR) determinations is essential. Based on past experience with the Thermo Exactive Orbitrap mass analyzer, the LS-APGD was interfaced with this instrument for these tests. While the Orbitrap platform has demonstrated excellent mass resolution and accuracy in “organic” mass spectrometry (MS) applications, work using an Orbitrap for IR analysis is very sparse. These efforts build off previous work in this coupling, where the importance of a few of the LS-APGD discharge parameters and Orbitrap data acquisition methods on IR precision and accuracy were probed. Presented here are the results of a study that evaluated the analytical precision for natural uranium sample (assumed 235U/238U = 0.0072) determinations. The instrumental parameters evaluated include the number of microscans and scans making up a data acquisition set, uranium concentration/signal level, sample make-up, and Fourier transform digitization window. Ultimately, a precision of 0.41% relative standard deviation (RSD) can be achieved for a single determination, with a reproducibility of 1.63 %RSD over 10 separate analytical measurements. A preliminary study of matrix effects on IR measurements of U is presented, highlighting the importance of pre-mass selection before injection into the Orbitrap. The analytical system sensitivity is suggested with the ability to produce a calibration function having an R2 value of >0.99 over a range of 4 orders of magnitude of concentration (~1 – 1000 ng mL-1). These efforts demonstrate the very promising pairing of the LS-APGD ionization source and the Orbitrap, pointing as well to definitive paths forward to better utilize both components in high quality isotope ratio mass spectrometry (IRMS).

Environmental Molecular Sciences Laboratory↗

Verification of the astrometric performance of the Korean VLBI network, using comparative SFPR studies with the VLBA AT 14/7 mm

The Korean VLBI Network (KVN) is a new millimeter VLBI dedicated array with the capability to simultaneously observe at multiple frequencies, up to 129 GHz. The innovative multi-channel receivers present significant benefits for astrometric measurements in the frequency domain. The aim of this work is to verify the astrometric performance of the KVN using a comparative study with the VLBA, a well-established instrument. For that purpose, we carried out nearly contemporaneous observations with the KVN and the VLBA, at 14/7 mm, in 2013 April. The KVN observations consisted of simultaneous dual frequency observations, while the VLBA used fast frequency switching observations. We used the Source Frequency Phase Referencing technique for the observational and analysis strategy. We find that having simultaneous observations results in superior compensation for all atmospheric terms in the observables, in addition to offering other significant benefits for astrometric analysis. We have compared the KVN astrometry measurements to those from the VLBA. We find that the structure blending effects introduce dominant systematic astrometric shifts, and these need to be taken into account. We have tested multiple analytical routes to characterize the impact of the low-resolution effects for extended sources in the astrometric measurements. The results from the analysis of the KVN and full VLBA data sets agree within 2σ of the thermal error estimate. We interpret the discrepancy as arising from the different resolutions. We find that the KVN provides astrometric results with excellent agreement, within 1σ, when compared to a VLBA configuration that has a similar resolution. Therefore, this comparative study verifies the astrometric performance of the KVN using SFPR at 14/7 mm, and validates the KVN as an astrometric instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of RF BPM Receivers for NSLS-II Project

The NSLS-II Light Source being built at Brookhaven National Laboratory requires submicron stability of the electron orbit in the storage ring in order to utilize fully very small emittances and electron beam sizes. This sets high stability requirements for beam position monitors and a program has been initiated for the purpose of characterizing RF beam position monitor (BPM) receivers in use at other light sources. Present state-of-the-art performance will be contrasted with more recently available technologies.

43 PARTICLE ACCELERATORS↗

Efficient and Selective Chemical Transformations in Highly Charged and Confined Nanodroplets

The acceleration of chemical reaction rates and the increased product selectivity in microdroplets compared to that in bulk solutions has become a topic of increasing interest that has been extensively characterized by electrospray ionization mass spectrometry (ESI-MS). However, the sources of this acceleration and the detailed relationships between droplet properties and resulting reaction rate acceleration are still under debate. Moreover, droplet properties are governed by multiple interrelated experimental parameters, i.e., electrospray voltage, solution flow rate, etc., which makes it difficult and time-consuming to explore this diverse parameter space using traditional manual experimental or computational approaches. In this work, we developed an automated experimental platform integrating reactions in controlled charged microdroplet environments with ESI-MS characterization and sequential hybrid Bayesian modeling, as well as an optimal experimental design framework, to achieve multidimensional parameter optimization for higher reaction turnover rates, based on a model reaction of tetraethylenepentamine (TEPA) with carbon dioxide. With the current platform, we have achieved automated scans with a range of electrospray voltages and solution flow rates, and determined and optimized parameter settings to achieve increased reaction turnovers. We have also linked this platform to the underlying properties of droplets via a hybrid model incorporating physics, high-level theoretical calculations, and machine learning (ML) approaches. The autonomous platform is broadly applicable to a range of chemical reactions relevant to DOE’s mission in chemical separations, catalysis, and materials synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commissioning of Phase 1 of the LANL RFQ Test Stand - Beam Characterization

A series of numerical start-to-end simulations of Phase 1 of the 750 keV RFQ Test Stand which includes the ion source (H+ duoplasmatron), a 1-Solenoid LEBT, an emittance scan station and a Faraday cup were performed to find a mechanism for the characterization of the proton beam extracted from the duoplasmatron.

43 PARTICLE ACCELERATORS↗

Flow Characterization of Compressed Woody Biomass

Global interest for using terrestrial biomass as an energy source has been increasing recently due to potentially significant socio-economic and environmental benefits relative to fossil energy. Thermochemical biomass processes converting biomass to fuels are relatively well developed, e.g. for direct combustion, gasification, and pyrolysis. However, critical problems often arise when attempting to feed biomass into commercial-scale reactors continuously and without interruption. Biomass particles, whether derived from woody or agricultural feedstock, vary greatly in size, shape, density, and moisture content. High cohesiveness, low bulk density, and poor material flow characteristics often prevent continuous feeding due to bridging, rat-hole formation, blockage, and seal failures. Among all different types of feeders utilized to feed biomass into reactors, screw feeding has received significant attention in recent years. Screw feeders are fuel-specific and require careful design to be reliable, efficient, and economical, especially for reactors operating at elevated pressures. In order to mimic the flow properties of compressed biomass inside a compression-screw feeder, rheological properties of three types of compressed lignocellulosic biomass were investigated using a co-rotating twin screw microcompounder. Experiments were conducted to find the impact of moisture content, particle size and type, and screw speed on rheological properties of forest residual particles as well as sawdust. Increasing moisture from 10 to 50% reduced the apparent viscosity of the compressed biomass. Also, higher screw speeds (10 to 90 rpm) led to a lower relative viscosity. At elevated screw speeds, significant temperature differences were measured between the initial and final states, which should be accounted for in equipment design and operation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Spatiotemporal temperature and density characterization of high-power atmospheric flashover discharges over inert poly(methyl methacrylate) and energetic pentaerythritol tetranitrate dielectric surfaces

A flashover arc source that delivered up to 200 mJ on the 100s-of-ns time-scale to the arc and a user-selected dielectric surface was characterized for studying high-explosive kinetics under plasma conditions. The flashover was driven over thin pentaerythritol tetranitrate (PETN) and poly(methyl methacrylate) (PMMA) dielectric films and the resultant plasma was characterized in detail. Time- and space-resolved temperatures and electron densities of the plasma were obtained using atomic emission spectroscopy. The hydrodynamics of the plasma was captured through fast, visible imaging. Fourier transform infrared spectroscopy (FTIR) was used to characterize the films pre- and post-shot for any chemical alterations. Time-resolved infrared spectroscopy (TRIR) provided PETN depletion data during the plasma discharge. For both types of films, temperatures of 1.6-1.7 eV and electron densities of {approx}7-8 x 10{sup 17}/cm{sup 3}{approx}570 ns after the start of the discharge were observed with temperatures of 0.6-0.7 eV persisting out to 15 {mu}s. At 1.2 {mu}s, spatial characterization showed flat temperature and density profiles of 1.1-1.3 eV and 2-2.8 x 10{sup 17}/cm{sup 3} for PETN and PMMA films, respectively. Images of the plasma showed an expanding hot kernel starting from radii of {approx}0.2 mm at {approx}50 ns and reaching {approx}1.1 mm at {approx}600 ns. The thin films ablated or reacted several hundred nm of material in response to the discharge. First TRIR data showing the in situ reaction or depletion of PETN in response to the flashover arc were successfully obtained, and a 2-{mu}s, 1/e decay constant was measured. Preliminary 1 D simulations compared reasonably well with the experimentally determined plasma radii and temperatures. These results complete the first steps to resolving arc-driven PETN reaction pathways and their associated kinetic rates using in situ spectroscopy techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Gamma-Ray Imagers Using GADRAS

This document describes how gamma-ray imagers are characterized using the Gamma Detector Response and Analysis Software (GADRAS). The initial step of the characterization process entails definition of detector dimensions and estimation of a few parameters that are specific to gamma-ray imagers. Energy calibration and resolution parameters are then adjusted based on comparison between computed spectra and measurements for several calibration source. These steps are analogous to the way non-imaging spectrometers are characterized. The parameters are then refined by an empirical process to achieved good agreement between measured and computed spectra as functions of gamma-ray energy and angular group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and Analysis of Performance-Advantaged Bioproducts

Performance-advantaged bioproducts (PABPs) are "novel products where the bio-based product does not resemble an existing petroleum-derived molecule but offers a performance advantage over existing products" (Fitzgerald, Bailey 2018). PABPs are an exciting area with near-term potential to accelerate the bioeconomy. We focus on synthesis, characterization, and economic and sustainability analyses for PABPs, aiming to leverage the inherent chemical functionality of molecules from carbohydrates and lignin via chemical and biological transformations. We collaborate with other BETO projects to source new molecules. Our work is integrated with the Inverse Design project, which provides computational predictions for PABPs and first principles-based results to explain observed properties. Primary outcomes include 1) a Nature Reviews Materials paper that establishes PABP design principles, 2) PA nylons from beta-ketoadipic acid, 3) new recyclable thermosets from bio-aromatic amines, 4) new PA plasticizers that are less toxic, and 5) the experimental validation of a machine learning tool, PolyML, from the Inverse Design project. Going forward, we are working towards an integrated framework to dramatically narrow PABP design space and a materials flow analysis of commodity chemicals as a benchmark for PABPs. Our main challenges are in the sourcing of new molecules that are not commercially available and the need for comprehensive characterizations and scale-up for technology transfer.

BIOMASS FUELS↗