Search NASA⌕ Search

SEARCH · Search NASA

Results for “source configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Development of a Characterized Radiation Field for Evaluating Sensor Performance

Numerous efforts are funded by US agencies (DOE, DoD, DHS) for development of novel radiation sensing and measurement systems. An effort has been undertaken to develop a flexible shielding system compatible with a variety of sources (beta, X-ray, gamma, and neutron) that can be highly characterized using conventional radiation detection and measurement systems. Sources available for use in this system include americium-beryllium (AmBe), plutonium-beryllium (PuBe), strontium-90 (Sr-90), californium-252 (Cf-252), krypton-85 (Kr-85), americium-241 (Am-241), and depleted uranium (DU). Shielding can be varied by utilization of materials that include lexan, water, oil, lead, and polyethylene. Arrangements and geometries of source(s) and shielding can produce symmetrical or asymmetrical radiation fields. The system has been developed to facilitate accurately repeatable configurations. Measurement positions are similarly capable of being accurately re-created. Stand-off measurement positions can be accurately re-established using differential global positioning system (GPS) navigation. Instruments used to characterize individual measurement locations include a variety of sodium iodide (NaI(Tl)) (3 x 3 inch, 4 x 4 x 16 inch, Fidler) and lithium iodide (LiI(Eu)) detectors (for use with multichannel analyzer software) and detectors for use with traditional hand held survey meters such as boron trifluoride (BF{sub 3}), helium-3 ({sup 3}He), and Geiger-Mueller (GM) tubes. Also available are Global Dosimetry thermoluminescent dosimeters (TLDs), CR39 neutron chips, and film badges. Data will be presented comparing measurement techniques with shielding/source configurations. The system is demonstrated to provide a highly functional process for comparison/characterization of various detector types relative to controllable radiation types and levels. Particular attention has been paid to use of neutron sources and measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Skin dose mapping for fluoroscopically guided interventions

Purpose: To introduce a new skin dose mapping software system for interventional fluoroscopy dose assessment and to analyze the benefits and limitations of patient-phantom matching. Methods: In this study, a new software system was developed for visualizing patient skin dose during interventional fluoroscopy procedures. The system works by translating the reference point air kerma to the location of the patient's skin, which is represented by a computational model. In order to orient the model with the x-ray source, geometric parameters found within the radiation dose structured report (RDSR) are used along with a limited number of in-clinic measurements. The output of the system is a visual indication of skin dose mapped onto an anthropomorphic model at a resolution of 5 mm. In order to determine if patient-dependent and patient-sculpted models increase accuracy, peak skin dose was calculated for each of 26 patient-specific models and compared with doses calculated using an elliptical stylized model, a reference hybrid model, a matched patient-dependent model and one patient-sculpted model. Results were analyzed in terms of a percent difference using the doses calculated using the patient-specific model as the true standard. Results: Anthropometric matching, including the use of both patient-dependent and patient-sculpted phantoms, was shown most beneficial for left lateral and anterior-posterior projections. In these cases, the percent difference using a reference model was between 8 and 20%, using a patient-dependent model between 7 and 15%, and using a patient-sculpted model between 3 and 7%. Under the table tube configurations produced errors less than 5% in most situations due to the flattening affects of the table and pad, and the fact that table height is the main determination of source-to-skin distance for these configurations. In addition to these results, several skin dose maps were produced and a prototype display system was placed on the in-clinic monitor of an interventional fluoroscopy system. Conclusions: The skin dose mapping program developed in this work represents a new tool that, as the RDSR becomes available through automated export or real-time streaming, can provide the interventional physician information needed to modify behavior when clinically appropriate. The program is nonproprietary and transferable, and also functions independent to the software systems already installed on the control room workstation. The next step will be clinical implementation where the workflow will be optimized along with further analysis of real-time capabilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Schwarz method for earthquake source dynamics

Dynamic faulting under slip-dependent friction in a linear elastic domain (in-plane and 3D configurations) is considered. The use of an implicit time-stepping scheme (Newmark method) allows much larger values of the time step than the critical CFL time step, and higher accuracy to handle the non-smoothness of the interface constitutive law (slip weakening friction). The finite element form of the quasi-variational inequality is solved by a Schwarz domain decomposition method, by separating the inner nodes of the domain from the nodes on the fault. In this way, the quasi-variational inequality splits into two subproblems. The first one is a large linear system of equations, and its unknowns are related to the mesh nodes of the first subdomain (i.e. lying inside the domain). The unknowns of the second subproblem are the degrees of freedom of the mesh nodes of the second subdomain (i.e. lying on the domain boundary where the conditions of contact and friction are imposed). This nonlinear subproblem is solved by the same Schwarz algorithm, leading to some local nonlinear subproblems of a very small size. Numerical experiments are performed to illustrate convergence in time and space, instability capturing, energy dissipation and the influence of normal stress variations. We have used the proposed numerical method to compute source dynamics phenomena on complex and realistic 2D fault models (branched fault systems)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectrally resolved fluorescence diffuse tomography of biological tissues

Spectrally resolved fluorescence diffuse tomography (SFDT) is demonstrated to be an effective approach to the reconstruction of the fluorescent agent distribution in biological tissues. Analysis of the measured optical power spectrum enables more accurate fluorophore localisation in solving the inverse tomography problem, because the dispersion of the optical parameters of the imaging subject leads to characteristic changes in the shape of its fluorescence spectrum. The SFDT system built by us includes a common optical fibre output of light sources and a single fibre input of the detector in an on-axis configuration, and an electromechanical scanner. The system enables studies of laboratory animals having tumours labelled with various fluorescent agents (fluorescent proteins, quantum dots and others). The first in vivo experiments have demonstrated the feasibility of tumour detection and localisation in laboratory animals by SFDT. (optical tomography)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Search for time-independent neutrino emission from astrophysical sources with 3 yr of IceCube data

We present the results of a search for neutrino point sources using the IceCube data collected between 2008 April and 2011 May with three partially completed configurations of the detector: the 40-, 59-, and 79-string configurations. The live-time of this data set is 1040 days. An unbinned maximum likelihood ratio test was used to search for an excess of neutrinos above the atmospheric background at any given direction in the sky. By adding two more years of data with improved event selection and reconstruction techniques, the sensitivity was improved by a factor of 3.5 or more with respect to the previously published results obtained with the 40-string configuration of IceCube. We performed an all-sky survey and a dedicated search using a catalog of a priori selected objects observed by other telescopes. In both searches, the data are compatible with the background-only hypothesis. In the absence of evidence for a signal, we set upper limits on the flux of muon neutrinos. For an E {sup –2} neutrino spectrum, the observed limits are (0.9-5) × 10{sup –12} TeV{sup –1} cm{sup –2} s{sup –1} for energies between 1 TeV and 1 PeV in the northern sky and (0.9-23.2) × 10{sup –12} TeV{sup –1} cm{sup –2} s{sup –1} for energies between 10{sup 2} TeV and 10{sup 2} PeV in the southern sky. We also report upper limits for neutrino emission from groups of sources that were selected according to theoretical models or observational parameters and analyzed with a stacking approach. Some of the limits presented already reach the level necessary to quantitatively test current models of neutrino emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Cohomologies of Configuration Spaces and Higher-Dimensional Polylogarithms in Renormalization Group Problems

The deviation from commutativity of the renormalization and the action of all linear partial differential operators is the main source of the anomalies in quantum field theory, including the renormalization group action. This deviation is characterized by certain 'renormalization cocycles' that are related to cohomologies of the so called (ordered) configuration spaces. Cohomological differential equations that determine the renormalization cocycles up to the renormalization freedom are obtained. The solution of these equations requires introducing transcendental extensions related to higher-dimensional polylogarithms.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design of a 2.5 Gbps Optical Transmitter for the International Space Station

A high data rate laser transmitter assembly (LTA) has been designed as the source for an optical free-space communication link between the International Space Station and the 1-meter Optical Communication Telescope Laboratory (OCTL) to be built at the Table Mountain Facility (IMF, Wrightwood, CA). The transmitter design concept uses a fiber-based master oscillator power amplifier (MOPA) configuration with an average output power of 200 made at a 1550 nm transmit wavelength. This transmitter source is also designed to provide a signal at 980 nm to the Silicon-based focal plane array for the point-ahead beam control function. This novel integration of a 980 nm boresight signal allows the use of Silicon based imagers for the acquisition/tracking and point-ahead functions, yet permits the transmit signal to be at any wavelength outside the Silicon sensitivity. The LTA, a sub-system of the Flight Terminal, has been designed to have a selectable data rate from 155 - 2500 Mbps in discrete steps. It also incorporates a 2.5 Gbps pseudo-random bit sequence (PRBS) generator for complete link testing and diagnostics. The design emphasizes using commercial off the shelf components (COTS).

Ortiz, Gerardo G.↗

ParaStell: parametric modeling and neutronics support for stellarator fusion power plants

The three-dimensional variation inherent to stellarator geometries and fusion sources motivates three-dimensional modeling to obtain accurate results from computational modeling in support of design and analysis of first wall, blanket, and shield (FWBS) systems. Manually constructing stellarator fusion power plant geometries in computer-aided design (CAD) and defining the corresponding fusion source can be cumbersome and challenging. The open-source parametric modeling toolset ParaStell has been developed to automate construction of such geometries in low-fidelity. Low-fidelity modeling is useful during the conceptual phase of engineering design as a means of rapidly exploring the design space of a given device. The modeling capability of ParaStell includes in-vessel components and magnets, for any given stellarator configuration, using a parametric definition and plasma equilibrium data. Furthermore, the toolset automates the generation of detailed, tetrahedral neutron source definitions and DAGMC geometries for use in neutronics modeling. ParaStell assists rapid design iteration, parametric study, and design optimization of stellarator fusion cores. As a demonstration of the design iteration capability, the effect of the three-dimensional parameter space on tritium breeding and magnet shielding is investigated, using the WISTELL-D configuration as a design basis. Blanket and shield thicknesses are varied in three dimensions, using the space available between the plasma edge and magnet coils as a constraint. The corresponding effects on tritium breeding ratio and magnet heating are tallied using the open-source Monte Carlo particle transport code OpenMC. The inclusion of additional and higher-fidelity modeling capabilities is planned for ParaStell’s future, as well as its implementation in machine-driven optimization.

Moreno, Connor↗

Characterization of a Polyethylene Moderated Highly Enriched Uranium System

The polyethylene interstitial materials for the Class Foils experiment are one of the teaching tools used to teach criticality safety at the National Criticality Experiments Research Center (NCERC). This set of polyethylene plates is designed to provide the optimal H/{sup 235}U ratio on the critical mass curve allowing the experiment to have the minimum amount of {sup 235}U. This makes a great teaching tool to show that either additional {sup 235}U or additional moderator would increase the critical mass. The optimal H/{sup 235}U ratio and increased hydrogen density compared to the previously used Lucite plates has reduced the critical mass by 34%, to 997.9 ± 0.65 g. The robustness of this experiment makes it ideal for hands on training. The fuel foils consist of thin highly enriched uranium (93 wt% {sup 235}U) metal foils laminated in plastic; each foil weighs approximately 68 grams. The fuel is interleaved between interstitial plates to attain a critical configuration. The critical configuration requires 14.5 fuel foils. Rossi-α experiments have been proposed as a method of benchmarking kinetics properties given by neutronics codes such as MCNP. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Distributed gather/scatter operations across a network of memory nodes

Devices, methods, and systems for distributed gather and scatter operations in a network of memory nodes. A responding memory node includes a memory; a communications interface having circuitry configured to communicate with at least one other memory node; and a controller. The controller includes circuitry configured to receive a request message from a requesting node via the communications interface. The request message indicates a gather or scatter operation, and instructs the responding node to retrieve data elements from a source memory data structure and store the data elements to a destination memory data structure. The controller further includes circuitry configured to transmit a response message to the requesting node via the communications interface. The response message indicates that the data elements have been stored into the destination memory data structure.

97 MATHEMATICS AND COMPUTING↗

Effects of Cavity Diameter on Acoustic Impedance in a Complex Acoustic Environment

This paper investigates the effects of cavity diameter on the acoustic performance of conventional perforate-over-honeycomb liners. This investigation is a follow up to a previous study where it was demonstrated that the cavity diameter has a relatively small effect on the acoustic impedance for core cavity diameters up to 2.0 inches. In the current study, liner concepts are exposed to a complex acoustic environment, where higher-order modes are present. Four liner configurations are explored in this investigation, which include two cavity cores of different cavity diameters combined with two facesheets. These configurations are tested in the Grazing Flow Impedance Tube (GFIT) at Mach 0.0, 0.3, and 0.5 at a source sound pressure level of 150 dB. A comparison of the acoustic performance of these samples suggests that the cavity diameter has a relatively small effect on the acoustic impedance for core cavity diameters up to 2.0 inches at these conditions. These configurations are exposed to a more complex acoustic environment (e.g., higher-order modes) in the Curved Duct Test Rig (CDTR) at Mach 0.0 and 0.3.

Brown, M. C.↗

Multi-modular power plant with off-grid power source

A multi-modular power plant may include a plurality of on-site nuclear power modules configured to generate a power plant output, wherein one or more of the nuclear power modules may be designated as service module units which are configured to generate a first portion of the power plant output. A remainder of the nuclear power modules may be configured to generate a second portion of the power plant output. A number of power plant systems may be configured to operate using electricity associated with a house load of the power plant, wherein the first portion of the power plant output is equal to or greater than the house load. Additionally, a switchyard may be configured to electrically connect the power plant to a distributed electrical grid. The distributed electrical grid may be configured to service a plurality of geographically distributed consumers, and the switchyard may be configured to apply the second portion of the power plant output to the distributed electrical grid. The switchyard may further be configured to apply at least part of the first portion of the power plant output to the power plant systems during a loss of power from the distributed electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Time-tagged Neutron Source for SNM Detection

Associated particle imaging (API) is a powerful technique for special nuclear material (SNM) detection and characterization of fissile material configurations. A sealed-tube neutron generator has been under development by Lawrence Berkeley National Laboratory to reduce the beam spot size on the neutron production target to 1 mm in diameter for a several-fold increase in directional resolution and simultaneously increases the maximum attainable neutron flux. A permanent magnet 2.45 GHz microwave-driven ion source has been adopted in this time-tagged neutron source. This type of ion source provides a high plasma density that allows the use of a sub-millimeter aperture for the extraction of a sufficient ion beam current and lets us achieve a much reduced beam spot size on target without employing active focusing. The design of this API generator uses a custom-made radial high voltage insulator to minimize source to neutron production target distance and to provide for a simple ion source cooling arrangement. Preliminary experimental results showed that more than 100 µA of deuterium ions have been extracted, and the beam diameter on the neutron production target is around 1 mm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Utilization of the High Flux Isotope Reactor at Oak Ridge National Laboratory

This paper addresses several aspects of the scientific utilization of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). Topics to be covered will include: 1) HFIR neutron scattering instruments and the formal instrument user program; 2) Recent upgrades to the neutron scattering instrument stations at the reactor, and 3) eMod a new tool for addressing instrument modifications and providing configuration control and design process for scientific instruments at HFIR and the Spallation Neutron Source (SNS). There are 15 operating neutron instrument stations at HFIR with 12 of them organized into a formal user program. Since the last presentation on HFIR instruments at IGORR we have installed a Single Crystal Quasi-Laue Diffractometer instrument called IMAGINE; and we have made significant upgrades to HFIR neutron scattering instruments including the Cold Triple Axis Instrument, the Wide Angle Neutron Diffractometer, the Powder Diffractometer, and the Neutron Imaging station. In addition, we have initiated upgrades to the Thermal Triple Axis Instrument and the Bio-SANS cold neutron instrument detector system. All of these upgrades are tied to a continuous effort to maintain a high level neutron scattering user program at the HFIR. For the purpose of tracking modifications such as those mentioned and configuration control we have been developing an electronic system for entering instrument modification requests that follows a modification or instrument project through concept development, design, fabrication, installation, and commissioning. This system, which we call eMod, electronically leads the task leader through a series of questions and checklists that then identifies such things as ES&H and radiological issues and then automatically designates specific individuals for the activity review process. The system has been in use for less than a year and we are still working out some of the inefficiencies, but we believe that this will become a very effective tool for achieving the configuration and process control believed to be necessary for scientific instrument systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AN ANGLE-DEPENDENT SYNCHROTRON SELF-COMPTON MODEL FOR RELATIVISTIC JET SOURCES

We report on the development of a numerical code to calculate the angle-dependent synchrotron + synchrotron self-Compton radiation from relativistic jet sources with partially ordered magnetic fields and anisotropic particle distributions. Using a multi-zone radiation transfer approach, we can simulate magnetic-field configurations ranging from perfectly ordered (unidirectional) to randomly oriented (tangled). We demonstrate that synchrotron self-Compton model fits to the spectral energy distributions (SEDs) of extragalactic jet sources may be possible with a wide range of magnetic-field values, depending on their orientation with respect to the jet axis and the observer. This is illustrated with the example of a spectral fit to the SED of Mrk 421 from multiwavelength observations in 2006, where acceptable fits are possible with magnetic-field values varying within a range of an order of magnitude for different degrees of B-field alignment and orientation.

79 ASTRONOMY AND ASTROPHYSICS↗

Technical Review Report for the Model 9977 Safety Analysis Report for Packaging Addendum 1 Justification for DNDO Contents

The Model 9977 Package is currently certified for Content Envelope C.1, {sup 238}Pu Heat Sources, either in Radioisotope Thermoelectric Generator (RTG), or in Food-Pack Can configurations, under Certificate of Compliance (CoC) Certificate Number 9977 and Package Identification Number USA/9977/B(M)F-96 (DOE). Addendum 1, Justification for DNDO Contents,--the Submittal--supplements Revision 2 of the Safety Analysis Report for Packaging for the Model 9977 Package. The Submittal adds five new contents to the Model 9977 Package, Content Envelopes, AC.1 through AC.5. The Content Envelopes are neptunium metal, the beryllium-reflected plutonium ball (BeRP Ball), plutonium/uranium metal, plutonium/uranium metal with enhanced wt% {sup 240}Pu (to 50 wt%), and uranium metal. The last three Content Envelopes are stabilized to DOE-STD-3013. These Content Envelopes will be shipped to the Device Assembly Facility (DAF) at the Nevada Test Site (NTS), where they will reside, and, hence, to off-site locations in support of the Department of Homeland Security (DHS) Domestic Nuclear Detection Office (DNDO). The new certificate will apply to a limited number of Model 9977 Packages. At the same time, the Submittal requests an extension of the periodic maintenance requirements from one (1) year to up to five (5) years using Radio-Frequency Identification (RFID) temperature-monitoring systems to measure the ambient storage temperature in order to ensure that the temperature of the Viton{reg_sign} O-rings for the 6-inch Containment Vessel (6CV) remain less than 200 F. The RFIDs have been developed by Argonne National Laboratory. An on-going surveillance program at the K-Area Materials Storage (KAMS) facility at the Savannah River Site, and an on-going examination of Viton{reg_sign} O-rings from mock Primary Containment Vessels (PCVs) at Savannah River National Laboratory (SRNL) provide the technical justification for the extension of the periodic maintenance interval. Where extended periodic maintenance is desired, the decay heat rate for the Model 9977 Package is limited to 15 watts.

99 GENERAL AND MISCELLANEOUS↗

Elucidating High Field Phases of the Multiferroic MnWO4 with a Pulsed Magnetic Field and Time of Flight Neutron Laue Diffraction

We have combined time-of-flight neutron Laue diffraction and pulsed high magnetic fields at the Spallation Neutron Source to study the phase diagram of the multiferroic material MnWO4. The control of the field-pulse timing enabled an exploration of magnetic Bragg scattering through the time dependence of both the neutron wavelength and the pulsed magnetic field. This allowed us to observe several magnetic Bragg peaks in different field-induced phases of MnWO4 with a single instrument configuration. These phases were not previously amenable to neutron diffraction studies due to the large fields involved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗