Permanent-magnet-less machine having an enclosed air gap

A permanent magnet-less, brushless synchronous system includes a stator that generates a magnetic rotating field when sourced by an alternating current. An uncluttered rotor disposed within the magnetic rotating field is spaced apart from the stator to form an air gap relative to an axis of rotation. A stationary excitation core spaced apart from the uncluttered rotor by an axial air gap and a radial air gap substantially encloses the stationary excitation core. Some permanent magnet-less, brushless synchronous systems include stator core gaps to reduce axial flux flow. Some permanent magnet-less, brushless synchronous systems include an uncluttered rotor coupled to outer laminations. The quadrature-axis inductance may be increased in some synchronous systems. Some synchronous systems convert energy such as mechanical energy into electrical energy (e.g., a generator); other synchronous systems may convert any form of energy into mechanical energy (e.g., a motor).

42 ENGINEERING↗

Inverter-Based Operation of Maui: Electromagnetic Transient Simulations

As larger and larger power systems approach and reach 100% inverter-based resource (IBR) operation during some hours of the year, questions arise regarding the stability of such extremely-high IBR power systems, the potential need for grid-forming (GFM) inverter technology, and the potential need for synchronous condensers. Relatedly, questions also arise about the ability of conventional positive sequence power system modeling tools to capture high-IBR system dynamics. This presentation introduces electromagnetic transient (EMT) simulations in PSCAD of the near-future (year 2023) Maui power system at and near 100% IBR operation and compares those simulations to positive sequence (PSSE) simulations. The Maui PSCAD model is parallelized on 30 cores and includes the entire transmission system (>200 three-phase buses), >170 individual and aggregate IBR models, four wind plants, and three synchronous generators plus six synchronous condensers at two locations. We investigate system stability with varying levels of inertia using conventional grid-following IBR controls, and then we investigate the impact of GFM controls on stability. Results suggest that: 1) positive sequence simulations can miss key dynamics in extremely high IBR cases; 2) EMT simulations can also miss key dynamics if inverter inner control dynamics are not modeled; 3) synchronous condensers can stabilize a system in which 100% of the energy is supplied by IBRs, even conventional grid-following IBRs; 4) GFM controls on just some of the IBRs can stabilize a 100% IBR power system, even if that system has zero inertia (i.e. no synchronous condensers, though synchronous condensers may be needed for other purposes such as protection system operations).

41 EE - Solar Energy Technologies Office (EE-4S)↗

Nonlinear interaction of drift waves with driven plasma currents

In a cylindrical magnetized plasma, coherent drift wave modes are synchronized by a mode selective drive of plasma currents. Nonlinear effects of the synchronization are investigated in detail. Frequency pulling is observed over a certain frequency range. The dependence of the width of this synchronization range on the amplitude of the driven plasma currents forms Arnold tongues. The transition between complete and incomplete synchronization is indicated by the onset of periodic pulling and phase slippage. Synchronization is observed for driven current amplitudes, which are some percent of the typical value of parallel currents generated by drift waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distribution System Blackstart and Restoration Using DERs and Dynamically Formed Microgrids

Extreme weather events have led to long-duration outages in the distribution system (DS), necessitating novel approaches to blackstart and restore the system. Existing blackstart solutions utilize blackstart units to establish multiple microgrids (MGs), sequentially energize non-blackstart units, and restore loads. However, these approaches often result in isolated MGs. In DERs-aided blackstart, the continuous operation of these MGs is limited by the finite energy capacity of commonly used blackstart units like battery energy storage (BES)-based gridforming inverters (GFMIs). To address this issue, this article proposes a holistic blackstart and restoration framework that incorporates synchronization between dynamic MGs and the entire DS with the transmission grid (TG). To support synchronization, we leveraged virtual synchronous generator-based control for GFMIs to estimate their frequency response to load pick-up events using only initial/final quasi-steady-state points. Subsequently, a synchronization switching condition is developed to model synchronizing switches, aligning them seamlessly with a linearized branch flow problem. Finally, we designed a bottomup blackstart and restoration framework that considers the switching structure of the DS, energizing/synchronizing switches, DERs with grid-following inverters, and BES-based GFMIs with frequency security constraints. In conclusion, the proposed framework is validated in IEEE-123-bus system, considering cases with two and four GFMIs under various TG recovery instants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flight-Like Ground Demonstrations of Precision Maneuvers for Spacecraft Formations

Synchronized formation rotations are a common maneuver for planned precision formations. In such a rotation, attitudes remain synchronized with relative positions, as if the spacecraft were embedded in a virtual rigid body. Further, since synchronized rotations are needed for science data collection, this maneuver requires the highest precision control of formation positions and attitudes. A recently completed, major technology milestone for the Terrestrial Planet Finder Interferometer is the high-fidelity, ground demonstration of precision synchronized formation rotations. These demonstrations were performed in the Formation Control Testbed (FCT), which is a flight-like, multi-robot formation testbed. The FCT is briefly introduced, and then the synchronized rotation demonstration results are presented. An initial error budget consisting of formation simulations is used to show the connection between ground performance and TPF-I flight performance.

formation flying↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation: Preprint

This paper develops a non-phase-locked loop (PLL) grid-connected inverter that can improve the microgrid’s transients during transition operation. By emulating the operation of a synchronous machine, the inverter generates its own voltage and frequency during startup, synchronizes and connects to the grid, then operates in reactive power mode (grid-feeding) with self-generated voltage and frequency, and switches to voltage-frequency mode to establish system voltage and frequency (grid-forming) when the microgrid disconnects from the main grid, and vice versa. To enable fast synchronization, active synchronization control is adopted both during inverter startup and microgrid reconnection operation. The simulation results show that the developed non-PLL grid-connected inverter works effectively to synchronize the inverter and microgrid to the grid and avoids a phase jump during microgrid transition operation. Thus, the microgrid’s transients are significantly improved with the proposed control technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An asynchronous traversal engine for graph-based rich metadata management

Rich metadata in high-performance computing (HPC) systems contains extended information about users, jobs, data files, and their relationships. Property graphs are a promising data model to represent heterogeneous rich metadata flexibly. Specifically, a property graph can use vertices to represent different entities and edges to record the relationships between vertices with unique annotations. The high-volume HPC use case, with millions of entities and relationships, naturally requires an out-of-core distributed property graph database, which must support live updates (to ingest production information in real time), low-latency point queries (for frequent metadata operations such as permission checking), and large-scale traversals (for provenance data mining). Among these needs, large-scale property graph traversals are particularly challenging for distributed graph storage systems. Most existing graph systems implement a "level synchronous" breadth-first search algorithm that relies on global synchronization in each traversal step. This performs well in many problem domains; but a rich metadata management system is characterized by imbalanced graphs, long traversal lengths, and concurrent workloads, each of which has the potential to introduce or exacerbate stragglers (i.e., abnormally slow steps or servers in a graph traversal) that lead to low overall throughput for synchronous traversal algorithms. Previous research indicated that the straggler problem can be mitigated by using asynchronous traversal algorithms, and many graph-processing frameworks have successfully demonstrated this approach. Such systems require the graph to be loaded into a separate batch-processing framework instead of being iteratively accessed, however. In this work, we investigate a general asynchronous graph traversal engine that can operate atop a rich metadata graph in its native format. We outline a traversal-aware query language and key optimizations (traversal-affiliate caching and execution merging) necessary for efficient performance. We further explore the effect of different graph partitioning strategies on the traversal performance for both synchronous and asynchronous traversal engines. Our experiments show that the asynchronous graph traversal engine is more efficient than its synchronous counterpart in the case of HPC rich metadata processing, where more servers are involved and larger traversals are needed. Furthermore, the asynchronous traversal engine is more adaptive to different graph partitioning strategies.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Enhanced flood synchrony and downstream severity in the Delaware River under rising temperatures

River floods threaten life and economic stability, with risks increasing globally, especially in densely populated coastal areas. In mountainous coastal watersheds like the Delaware River Basin, rising temperature is projected to reduce snowpack, reshaping upstream–downstream flood dynamics. However, the impact on flood synchronization between upland tributaries and estuarine mainstems remains poorly understood. Using multidecadal streamflow simulations from a high-resolution hydrological model, we find significant increases in the frequency and magnitude of synchronized floods under future warming scenarios, particularly severe floods (above the 75 th percentile). Under higher warming scenarios, snowpack and rain-on-snow floods in headwater subbasins nearly vanish. Surprisingly, this regime shift amplifies estuarine flooding by enhancing synchronization between historically snow-dominated subbasins and their downstream counterparts. Despite intensified synchronization and flood magnitude, cold-season flood risk declines due to fewer rain-on-snow events. Conversely, summer floods grow larger, more frequent, and synchronized, driving a seasonal reconfiguration of flood risk that should be considered in future mitigation strategies.

59 BASIC BIOLOGICAL SCIENCES↗

Developing a Reduced 240-Bus WECC Dynamic Model for Frequency Response Study of High Renewable Integration

The ongoing changes in the generation resource mix, driven by the rapid adoption of inverter-based resources (IBR) as well as the early retirement of synchronous generators, are bringing new challenges to the planning and operation of bulk electric power systems. Consequently, there is an increasing need to understand, design, and quantify the reliability service provision from IBRs by performing integrated scheduling and dynamic simulations. However, test systems that have consistent scheduling and dynamic models rarely exist largely because of the decoupled nature of the two simulations on a synchronous generator-dominated system. This paper develops the dynamic model of a reduced Western Electricity Coordinating Council (WECC) system. In conjunction with the existing scheduling model, it is suitable for integrating scheduling and dynamic simulations. The reduced 240-bus WECC model reflects the generation resource mix of the Western Interconnection as of 2018. Moreover, the developed dynamic model is validated against field frequency events measured by FNET/GridEye and preserves the dominant inter-area oscillation mode in WECC.

dynamic simulation↗

Oscillation Risks of Grid-Following and Grid-Forming Inverter-Based Resources in Series-Compensated Networks

Here, this paper investigates the dynamic behavior of a grid-connected inverter-based resource (IBR) when connected radially to a series compensated line. Potential interactions between the series compensation and the IBR have been identified for both types: grid-following (GFL) or grid-forming (GFM). The study begins with electromagnetic transient (EMT) simulations to demonstrate stability issues. Subsequently, nonlinear analytical models are formulated in the dq frame, validated against the EMT simulation, and leveraged to assess eigenvalues and participation factors. Influencing factors of the dominant oscillation modes have been identified. The analysis results show that series compensation may make a mode associated with the synchronization unit unstable. Furthermore, customized feedback systems are built for the synchronizing loop. Series compensation can increase the sensitivity of the voltage phase angle towards the synchronizing angle, and introduce phase lag in the real power response towards the synchronizing angle. These factors may cause interactions with the phase-locked loop in GFL-IBR systems and with power-based synchronization in GFM-IBR systems, potentially leading to instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physiological coherence in healthy volunteers during laboratory‐induced stress and controlled breathing

Abstract Physiological coherence has been related with a general sense of well‐being and improvements in health and physical, social, and cognitive performance. The aim of this study was to evaluate the relationship between acute stress, controlled breathing, and physiological coherence, and the degree of body systems synchronization during a coherence‐generation exercise. Thirty‐four university employees were evaluated during a 20‐min test consisting of four stages of 5‐min duration each, during which basal measurements were obtained (Stage 1), acute stress was induced using validated mental stressors (Stroop test and mental arithmetic task, during Stage 2 and 3, respectively), and coherence states were generated using a controlled breathing technique (Stage 4). Physiological coherence and cardiorespiratory synchronization were assessed during each stage from heart rate variability, pulse transit time, and respiration. Coherence measurements derived from the three analyzed variables increased during controlled respiration. Moreover, signals synchronized during the controlled breathing stage, implying a cardiorespiratory synchronization was achieved by most participants. Hence, physiological coherence and cardiopulmonary synchronization, which could lead to improvements in health and better life quality, can be achieved using slow, controlled breathing exercises. Meanwhile, coherence measured during basal state and stressful situations did not show relevant differences using heart rate variability and pulse transit time. More studies are needed to evaluate the ability of coherence ratio to reflect acute stress.

Mejía‐Mejía, Elisa↗

Small-amplitude synchrotron tune near transition

The separatrices of the rf buckets near transition are mapped when the synchronous phase is neither 0 or {pi}. The small-amplitude synchronous tune is derived when the rf frequency is changed. Synchrotron radiation is present in all electron storage ring. As a result, the synchronous phase is always offset from {phi}{sub s} = {pi} to compensate for the power loss. Even for proton storage rings with negligible synchrotron radiation, the synchronous phase is also required to be offset from {phi}{sub s} = 0 or {pi} slightly to compensate for beam loading. Thus for all storage rings operating near transition, beam particles reside in accelerating buckets instead of stationary bucket. It is of interest to map these buckets and see how they evolve near transition. When the rf frequency is varied, the closed orbit is pushed radially inward or outward. The momentum of the particle synchronous with the rf is thus changed. By measuring the small-amplitude synchrotron tune as a function of the rf frequency, the lowest first few orders of the slip factor can be inferred. Here, we derive this relationship up to the lowest first three orders of the slip factor when the particle velocity is not ultra-relativistic.

43 PARTICLE ACCELERATORS↗

Precise time transfer using MKIII VLBI technology

It is well known that Very Long Baseline Interferometry (VLBI) is capable of precise time synchronization at subnanosecond levels. This paper deals with a demonstration of clock synchronization using the MKIII VBLI system. The results are compared with clock synchronization by traveling cesium clocks and GPS. The comparison agrees within the errors of the portable clocks (+ 5 ns) and GPS(+ or - 30 ns) systems. The MKIII technology appears to be capable of clock synchronization at subnanosecond levels and appears to be very good benchmark system against which future time synchronization systems can be evaluated.

Johnston, K. J.↗

Comparing barrier algorithms

A barrier is a method for synchronizing a large number of concurrent computer processes. After considering some basic synchronization mechanisms, a collection of barrier algorithms with either linear or logarithmic depth are presented. A graphical model is described that profiles the execution of the barriers and other parallel programming constructs. This model shows how the interaction between the barrier algorithms and the work that they synchronize can impact their performance. One result is that logarithmic tree structured barriers show good performance when synchronizing fixed length work, while linear self-scheduled barriers show better performance when synchronizing fixed length work with an imbedded critical section. The linear barriers are better able to exploit the process skew associated with critical sections. Timing experiments, performed on an eighteen processor Flex/32 shared memory multiprocessor, that support these conclusions are detailed.

Arenstorf, Norbert S.↗

Comparing barrier algorithms

A barrier is a method for synchronizing a large number of concurrent computer processes. After considering some basic synchronization mechanisms, a collection of barrier algorithms with either linear or logarithmic depth are presented. A graphical model is described that profiles the execution of the barriers and other parallel programming constructs. This model shows how the interaction between the barrier algorithms and the work that they synchronize can impact their performance. One result is that logarithmic tree structured barriers show good performance when synchronizing fixed length work, while linear self-scheduled barriers show better performance when synchronizing fixed length work with an imbedded critical section. The linear barriers are better able to exploit the process skew associated with critical sections. Timing experiments, performed on an eighteen processor Flex/32 shared memory multiprocessor that support these conclusions, are detailed.

Arenstorf, Norbert S.↗

Timing in private digital telecommunication networks

For proper operation of today's large digital private networks, high quality synchronization must be achieved. A general telecommunication performance objective is to maintain long-term frequency accuracy of ten parts per trillion at all synchronous digital equipment in the network. Many times, however, this is not achieved in private networks. Low quality clocks, errored transmission facilities, and incorrectly designed synchronization plans are often cause for poor performance. It is shown that properly-designed private networks can operate with long term frequency averages between ten parts per trillion to ten parts per million. These performance levels can adversely impact customer applications. The most demanding applications are digital and voice band data, encrypted voice, facsimile, and video. In a typical private network operating at 0.01 parts per million, the user would experience reduced data throughput, dropped encrypted calls, unreadable facsimile pages, or interrupted video transmission dozens of times per day. The major contribution to poor private network synchronization performance is the interaction of Customer Premises Equipment (CPE) clocks and the network facilities used to distribute timing. The performance of typical CPE clocks and facilities, and their impact on customer applications, are discussed. CPE clock performance issues, along with private network architectural constraints, make synchronization planning extremely difficult. Planning is usually costly and requires specialized expertise.

Abate, J. E.↗

Loran-C time management

As of 1 Oct. 1993, the US Coast Guard (USCG) supports and operates fifteen Loran-C chains. With the introduction of the Global Positioning Systems (GPS) and the termination of the Department of Defense (DOD) overseas need for Loran-C, the USCG will cease operating the three remaining overseas chains by 31 Dec. 1994. Following this date, the USCG Loran-C system will consist of twelve chains. Since 1971, management of time synchronization of the Loran-C system has been conducted under a Memorandum of Agreement between the US Naval Observatory (USNO) and the USCG. The requirement to maintain synchronization with Coordinated Universal Time (UTC) was initially specified as +/- 25 microseconds. This tolerance was rapidly lowered to +/- 2.5 microseconds in 1974. To manage this synchronization requirement, the USCG incorporated administrative practices which kept the USNO appraised of all aspects of the master timing path. This included procedures for responding to timing path failures, timing adjustments, and time steps. Conducting these aspects of time synchronization depended on message traffic between the various master stations and the USNO. To determine clock adjustment the USCG relied upon the USNO's Series 4 and 100 updates so that the characteristics of the master clock could be plotted and controls appropriately applied. In 1987, Public Law 100-223, under the Airport and Airway Improvement Act Amendment, reduced the synchronization tolerance to approximately 100 nanoseconds for chains serving the National Airspace System (NAS). This action caused changes in the previous administrative procedures and techniques. The actions taken by the USCG to meet the requirements of this law are presented.

Justice, Charles↗

Cascaded clocks measurement and simulation findings

This paper will examine aspects related to network synchronization distribution and the cascading of timing elements. Methods of timing distribution have become a much debated topic in standards forums and among network service providers (both domestically and internationally). Essentially these concerns focus on the need to migrate their existing network synchronization plans (and capabilities) to those required for the next generation of transport technologies (namely, the Synchronous Digital Hierarchy (SDH), Synchronous Optical Networks (SONET), and Asynchronous Transfer Mode (ATM). The particular choices for synchronization distribution network architectures are now being evaluated and are demonstrating that they can indeed have a profound effect on the overall service performance levels that will be delivered to the customer. The salient aspects of these concerns reduce to the following: (1) identifying that the devil is in the details of the timing element specifications and the distribution of timing information (i.e., small design choices can have a large performance impact); (2) developing a standardized method of performance verification that will yield unambiguous results; and (3) presentation of those results. Specifically, this will be done for two general cases: an ideal input, and a noisy input to a cascaded chain of slave clocks.

Chislow, Don↗