Search NASA⌕ Search

SEARCH · Search NASA

Results for “test facilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Development of a Work Control System for Propulsion Testing at Stennis Space Center (SSC)

In 1996, Stennis Space Center was given management authority for all Propulsion Testing for NASA. Over the next few years several research and development (R&D) test facilities were completed and brought up to full operation in what is known as the E-Complex Test Facility at Stennis Space Center. This paper will explain the requirements and steps taken to develop the current Test Operations' electronic work control system. The Work Control System developed includes work authorization documents such as test preparation sheets, discrepancy reports, pre-test briefing reports, and test requests.

Messer, Elizabeth A.↗

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling and data analysis of the NASA-WSTF frictional heating apparatus - Effects of test parameters on friction coefficient

A theoretical model is being developed jointly by the NASA White Sands Test Facility (WSTF) and the University of California at Santa Barbara (UCSB) to analyze data generated from the WSTF frictional heating test facility. Analyses of the data generated in the first seconds of the frictional heating test are shown to be effective in determining the friction coefficient between the rubbing interfaces. Different friction coefficients for carobn steel and Monel K-500 are observed. The initial condition of the surface is shown to affect only the initial value of the friction coefficient but to have no significant influence on the average steady-state friction coefficient. Rotational speed and the formation of oxide film on the rotating surfaces are shown to have a significant effect on the friction coefficient.

Zhu, Sheng-Hu↗

Instrument tests with the new Leica AT401

In order to evaluate the performance of the Leica Absolute Tracker AT401 we devised a series of tests. The first was to compare the Laser Tracker distance measurements to our interferometer on a 30 m long horizontal bench. The second was a check of the horizontal angle measurement accuracy and the 'level to gravity' feature. The third was to check the warm up behaviour and the instrument stability. All these tests were performed in our underground test facility at sector 10 of the SLAC linac. The air-conditioning was turned off for the duration of the measurements. The temperature in the test facility was stable to 0.1 deg C. As a test that is closer to a real world application we performed part of a simplified version of the ISO 10360-10 test in one of the experimental halls at SLAC. The instrument tested was running firmware version 1.0.373.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ambient and building condition effects modeling of air-cooled natural circulation systems

Throughout the testing program at Natural convection Shutdown heat removal Test Facility (NSTF), strong influences of ambient conditions were observed in the experimental data when baseline tests were repeated under identical test procedures. Significant analysis efforts were conducted to gain understanding of these influences, and quantify the system response of the test facility. In this paper, an empirical model was developed based on theoretical considerations and using experimental data to correlate zero-power system flow rates with ambient meteorological conditions, including wind and temperatures. Coefficients in the model were determined based on best fitting of the experimental data set. The predictive capability of the empirical model was demonstrated by applying it to new sets of experimental data. Finally, after implementing the empirical model in both system-level thermal fluids and computational fluid dynamics modeling of the facility, simulations from both approaches resulted in accurate predictions in system natural circulation flow rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Fluctuating Static Pressure Measurements in a Large High Reynolds Number Transonic Cryogenic Wind Tunnel

Dynamic measurements of fluctuating static pressure levels were made using flush mounted high frequency response pressure transducers at eleven locations in the circuit of the National Transonic Facility (NTF) over the complete operating range of this wind tunnel. Measurements were made at test section Mach numbers from 0.2 to 1.2, at pressure from 1 to 8.6 atmospheres and at temperatures from ambient to -250 F, resulting in dynamic flow disturbance measurements at the highest Reynolds numbers available in a transonic ground test facility. Tests were also made independently at variable Mach number, variable Reynolds number, and variable drivepower, each time keeping the other two variables constant thus allowing for the first time, a distinct separation of these three important variables. A description of the NTF emphasizing its flow quality features, details on the calibration of the instrumentation, results of measurements with the test section slots covered, downstream choke, effects of liquid nitrogen injection and gaseous nitrogen venting, comparisons between air and nitrogen, isolation of the effects of Mach number, Reynolds number, and fan drive power, and identification of the sources of significant flow disturbances is included. The results indicate that primary sources of flow disturbance in the NTF may be edge-tones generated by test section sidewall re-entry flaps and the venting of nitrogen gas from the return leg of the tunnel circuit between turns 3 and 4 in the cryogenic mode of operation. The tests to isolate the effects of Mach number, Reynolds number, and drive power indicate that Mach number effects predominate. A comparison with other transonic wind tunnels shows that the NTF has low levels of test section fluctuating static pressure especially in the high subsonic Mach number range from 0.7 to 0.9.

Igoe, William B.↗

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).

Wernet, Mark P.↗

Recent Development Work with Self-Aligned Focusing Schlieren

A novel compact focusing schlieren instrument has recently been developed that eliminates the need for a separate source and cutoff grid. The technique works by projecting an image of a grid onto a retroreflective surface and then reimaging the projection back onto the original grid. By manipulating the polarization state of the light passing through the instrument, a single Rochon polarizing prism can be used to adjust the schlieren sensitivity by translating it along the instrument’s optical axis, which changes the in-plane offset between the reimaged projection and the original grid. This arrangement makes the instrument inherently self-aligned. Relative to conventional focusing schlieren instruments, which require alignment of a separate source grid and cutoff grid to achieve sensitivity, the setup time required in order to obtain high quality focusing schlieren images is significantly reduced. Further, the self-aligned nature of this instrument makes it insensitive to vibrations and allows for on-the-fly adjustments to field-of-view. In this paper we discuss recent work that has been performed to expand the capabilities of this self-aligned focusing schlieren instrument including: schlieren visualization at extreme angles for optically-restricted test facilities, 3D schlieren visualization using a light field camera, acquisition of high quality focusing schlieren images from facilities with low quality windows, and obtaining focusing schlieren images in full-scale ground test facilities.

Brett Bathel↗

Pyrotechnically Operated Valves for Testing and Flight

Pyrovalves still warrant careful description of their operating characteristics, which is consistent with the NASA mission - to assure that both testing and flight hardware perform with the utmost reliability. So, until the development and qualification of the next generation of remotely controlled valves, in all likelihood based on shape memory alloy technology, pyrovalves will remain ubiquitous in controlling flow systems aloft and will possibly see growing use in ground-based testing facilities. In order to assist NASA in accomplishing this task, we propose a three-phase, three-year testing program. Phase I would set up an experimental facility, a 'test rig' in close cooperation with the staff located at the White Sands Test Facility in Southern New Mexico.

Conley, Edgar G.↗

Power Systems Development Facility Gasification Test Campaign TC22

In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF), located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This report summarizes the results of TC22, the first test campaign using a high moisture lignite from Mississippi as the feedstock in the modified Transport Gasifier configuration. TC22 was conducted from March 24 to April 17, 2007. The gasification process was operated for 543 hours, increasing the total gasification operation at the PSDF to over 10,000 hours. The PSDF gasification process was operated in air-blown mode with a total of about 1,080 tons of coal. Coal feeder operation was challenging due to the high as-received moisture content of the lignite, but adjustments to the feeder operating parameters reduced the frequency of coal feeder trips. Gasifier operation was stable, and carbon conversions as high as 98.9 percent were demonstrated. Operation of the PCD and other support equipment such as the recycle gas compressor and ash removal systems operated reliably.

01 COAL, LIGNITE, AND PEAT↗

Power Systems Development Facility Gasification Test Campaign TC24

In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF), located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This report summarizes the results of TC24, the first test campaign using a bituminous coal as the feedstock in the modified Transport Gasifier configuration. TC24 was conducted from February 16, 2008, through March 19, 2008. The PSDF gasification process operated for about 230 hours in air-blown gasification mode with about 225 tons of Utah bituminous coal feed. Operational challenges in gasifier operation were related to particle agglomeration, a large percentage of oversize coal particles, low overall gasifier solids collection efficiency, and refractory degradation in the gasifier solids collection unit. The carbon conversion and syngas heating values varied widely, with low values obtained during periods of low gasifier operating temperature. Despite the operating difficulties, several periods of steady state operation were achieved, which provided useful data for future testing. TC24 operation afforded the opportunity for testing of various types of technologies, including dry coal feeding with a developmental feeder, the Pressure Decoupled Advanced Coal (PDAC) feeder; evaluating a new hot gas filter element media configuration; and enhancing syngas cleanup with water-gas shift catalysts. During TC24, the PSDF site was also made available for testing of the National Energy Technology Laboratory's fuel cell module and Media Process Technology's hydrogen selective membrane.

01 COAL, LIGNITE, AND PEAT↗

Power Systems Development Facility Gasification Test Campaign TC25

In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF), located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This report summarizes the results of TC25, the second test campaign using a high moisture lignite coal from the Red Hills mine in Mississippi as the feedstock in the modified Transport Gasifier configuration. TC25 was conducted from July 4, 2008, through August 12, 2008. During TC25, the PSDF gasification process operated for 742 hours in air-blown gasification mode. Operation with the Mississippi lignite was significantly improved in TC25 compared to the previous test (TC22) with this fuel due to the addition of a fluid bed coal dryer. The new dryer was installed to dry coals with very high moisture contents for reliable coal feeding. The TC25 test campaign demonstrated steady operation with high carbon conversion and optimized performance of the coal handling and gasifier systems. Operation during TC25 provided the opportunity for further testing of instrumentation enhancements, hot gas filter materials, and advanced syngas cleanup technologies. The PSDF site was also made available for testing of the National Energy Technology Laboratory's fuel cell module and Media Process Technology's hydrogen selective membrane with syngas from the Transport Gasifier.

01 COAL, LIGNITE, AND PEAT↗

Performance Analysis and Simulaion of the Hydraulic Scram System in TREAT Reactor

The Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL) serves a vital role in nuclear fuel safety research, enabling transient experiments that simulate reactivity excursions and accident scenarios. Central to these operations is the transient control rod drive system (TCRDS), which drives rapid motion of the transient control rods such that TREAT can simulate rapid power changes typical of reactor accidents. The reliability and performance of this system are critical for protecting both fuel specimens and reactor infrastructure. This study presents the initial phase of a two-year investigation into the dynamics and reliability of the TREAT hydraulic TCRDS. Conducted in collaboration with INL, the research employs a combined computational and experimental approach to analyze the system's response time, pressure transients, and potential failure modes. Emphasis is placed on understanding how fluid characteristics influence the TCRDS’s ability to achieve both rapid power changes and mechanical stability. The TRDS and the skid that powers it will be analyzed throughout this investigation. Computational modeling using computational fluid dynamics (CFD) will simulate the hydraulic response under varying conditions. In parallel, experimental testing planned at INL will validate these models and capture key performance metrics. This paper outlines the system design, analytical framework, and modeling strategies that form the foundation for later testing. Ultimately, this work aims to support improvements to the TCRDS’s design and reliability, contributing to the broader goal of enhancing nuclear fuel safety and sustaining TREAT’s mission as a premier nuclear fuel test facility.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Plasma And Beam Homogeneity Of The RF-Driven Negative Hydrogen Ion Source For ITER NBI

The neutral beam injection (NBI) system of ITER is based on a large RF driven negative hydrogen ion source. For good beam transmission ITER requires a beam homogeneity of better than 10%. The plasma uniformity and the correlation with the beam homogeneity are being investigated at the prototype ion sources at IPP. Detailed studies are carried out at the long pulse test facility MANITU with a source of roughly 1/8 of the ITER source size. The plasma homogeneity close to plasma grid is measured by optical emission spectroscopy and by fixed Langmuir probes working in the ion saturation region. The beam homogeneity is measured with a spatially resolved H{sub {alpha}} Doppler-shifted beam spectroscopy system. The plasma top-to-bottom symmetry improves with increasing RF power and increasing bias voltage which is applied to suppress the co-extracted electron current. The symmetry is better in deuterium than in hydrogen. The boundary layer near the plasma grid determines the plasma symmetry. At high ion currents with a low amount of co-extracted electrons the plasma is symmetrical and the beam homogeneity is typically 5-10%(RMS). The size scaling and the influence of the magnetic field strength of the filter field created by a plasma grid current is studied at the test facility RADI (roughly a 1/2 size ITER source) at ITER relevant RF power levels. In volume operation in deuterium (non-cesiated source), the plasma illumination of the grid is satisfying.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Test Beam and Irradiation Facilities

Progress in particle physics depends on a multitude of unique facilities and capabilities that enable to advance detector technologies. Among others, key facilities involve test beams and irradiation facilities, which allow users to test the performance and lifetime of their detectors under realistic conditions. Test beam facilities are particularly important for collider and neutrino detector applications, while irradiation facilities are crucial for collider as well as some space-based astro particle detectors. This contributed Snowmass paper aims to summarize existing test beam and irradiation facilities as well as develop the need and proposals for future facilities.

43 PARTICLE ACCELERATORS↗

FFTF Passive Safety Test Data for Benchmarks for New LMR Designs

Liquid Metal Reactors (LMRs) continue to be considered as an attractive concept for advanced reactor design. Software packages such as SASSYS are being used to im-prove new LMR designs and operating characteristics. Significant cost and safety im-provements can be realized in advanced liquid metal reactor designs by emphasizing inherent or passive safety through crediting the beneficial reactivity feedbacks associ-ated with core and structural movement. This passive safety approach was adopted for the Fast Flux Test Facility (FFTF), and an experimental program was conducted to characterize the structural reactivity feedback. The FFTF passive safety testing pro-gram was developed to examine how specific design elements influenced dynamic re-activity feedback in response to a reactivity input and to demonstrate the scalability of reactivity feedback results to reactors of current interest. The U.S. Department of En-ergy, Office of Nuclear Energy Advanced Reactor Technology program is in the pro-cess of preserving, protecting, securing, and placing in electronic format information and data from the FFTF, including the core configurations and data collected during the passive safety tests. Benchmarks based on empirical data gathered during operation of the Fast Flux Test Facility (FFTF) as well as design documents and post-irradiation examination will aid in the validation of these software packages and the models and calculations they produce. Evaluation of these actual test data could provide insight to improve analytical methods which may be used to support future licensing applications for LMRs

Wootan, David W.↗

Visualization of flow interaction in a channel flow produced by a pair of helically coiled rods

Helically coiled tubes have been considered in the design of steam generators or heat exchangers of next generation nuclear power plants. Its compactness, efficiency, and the capability to absorb thermal expansion are desirable for nuclear reactor designs. However, the complex flow generated by the helically coiled geometry can result in flow induced vibration (FIV). In order to predict the FIV, there have been efforts using Computational Fluid dynamics (CFD)4, 5 to be coupled with multi-mechanics simulations. However, it is required to validate CFD to have confidence in capturing the flow structure characteristics of the transient complex flow behavior and fluctuation. In the present study, a simplified helically coiled steam generator (HCSG) design experiment was built acquiring data for CFD validation purpose. It is not perfect representation of the multiple rods, however, the current test facility produced transient data of the flow interaction between the rods and flow fluctuations near the rods. Particle Image Velocimetry (PIV) was applied to visualize the turbulent flow in a channel with slant rods. The two dimensional turbulent flow fields were analyzed. The velocity components were defined as below. u = U + u' (1) v = V + v' (2) where u is the lateral velocity on x-axis, v is the vertical velocity on y-axis, U and V are the mean velocities, and u' and v' are the fluctuation. Reynolds number, Re, was calculated using the rod diameter, d = 15.9 mm, and the upstream approach velocity, V{sub 0} = 0.5 m/s. Re = V{sub 0} d/η (3) where η is the kinematic viscosity of water. The experiment was conducted at Re ≅ 9,000 considering the currently reasonable computing power. Flow visualization in a flow channel produced by helically coiled rods was performed using PIV. The mean velocity field and streamlines were presented in this paper. The vortical flow structures in the cavity between rods were observed. Because of the asymmetric geometry, the flow profile was skewed. Additional measurements and transient analysis will be conducted to produce benchmark data for FIV study using CFD. Also, a test facility with a 5-rod heat exchanger design is operating to produce more data as a further work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design, Project Execution, and Commissioning of the 1.8 K Superfluid Helium Refrigeration System for SRF Cryomodule Testing

The Fermilab Cryomodule Test Facility (CMTF) provides a test bed to measure the performance of superconducting radiofrequency (SRF) cryomodules (CM). These SRF components form the basic building blocks of future high intensity accelerators such as the International Linear Collider (ILC) and a Muon Collider. Linde Kryotechnik AG and Linde Cryogenics have designed, constructed and commissioned the superfluid helium refrigerator needed to support SRF component testing at the CMTF Facility. The hybrid refrigerator is designed to operate in a variety of modes and under a wide range of boundary conditions down to 1.8 Kelvin set by CM design. Special features of the refrigerator include the use of warm and cold compression and high efficiency turbo expanders.This paper gives an overview on the wide range of the challenging cooling requirements, the design, fabrication and the commissioning of the installed cryogenic system.

43 PARTICLE ACCELERATORS↗