Search NASA⌕ Search

SEARCH · Search NASA

Results for “Basic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Glomeromycotina: what is a species and why should we care?

Summary A workshop at the recent International Conference on Mycorrhiza was focused on species recognition in Glomeromycotina and parts of their basic biology that define species. The workshop was motivated by the paradigm‐shifting evidence derived from genomic data for sex and for the lack of heterokaryosis, and by published exchanges in Science that were based on different species concepts and have led to differing views of dispersal and endemism in these fungi. Although a lively discussion ensued, there was general agreement that species recognition in the group is in need of more attention, and that many basic assumptions about the biology of these important fungi including sexual or clonal reproduction, similarity or dissimilarity of nuclei within an individual, and species boundaries need to be re‐examined and scrutinized with current techniques.

Bruns, Thomas D.↗

Patterning corrosion-susceptible metallic alloys for digital image correlation in a scanning electron microscope: Patterning corrosion susceptible alloys for SEM-DIC

Here we investigate the self-assembly of gold nanoparticles on the surface of magnesium functionalized with 3-(aminopropyl)trimethoxysilane or 3-(mercaptopropyl)trimethoxysilane. These nanoparticles served as a speckle pattern for high magnification deformation tracking via digital image correlation combined with scanning electron microscopy. Controlling the pH of the gold nanoparticle suspension to a specific basicity passivated corrosion in magnesium and in three of its alloys to enable proper nanoparticle bonding and self-assembly. Magnesium was used as a model material as it is particularly difficult to modify for self-assembly because of its propensity to quickly form a thick oxide, hydroxide, and carbonate layer in the presence of oxygen, water, and carbon dioxide, respectively. Moreover, it corrodes in acidic and slightly basic solutions, further complicating the self-assembly process. Due to these difficulties, the successful self-assembly of nanoparticles on magnesium has not previously been reported, to the best of the authors' knowledge. This technique is potentially amendable to other corrosion-susceptible materials. Gold nanoparticles were self-assembled in a uniformly dispersed random distribution on pure cast magnesium, cast AM60 (Mg-6Al-0.5Mn), rolled WE43 (Mg-4Y-3Nd/Gd), and extruded ZE20 (Mg-2Zn-0.2Ce).

36 MATERIALS SCIENCE↗

Laboratory study of premixed H{sub 2}-air and H{sub 2}-N{sub 2}-air flames in a low-swirl injector for ultralow emissions gas turbines - article no. 031503

The objective of this study is to conduct laboratory experiments on low-swirl injectors (LSIs) to obtain the basic information for adapting LSI to burn H{sub 2} and diluted H{sub 2} fuels that will be utilized in the gas turbines of the integrated gasification combined cycle coal power plants. The LSI is a novel ultralow emission dry-low NOx combustion method that has been developed for gas turbines operating on natural gas. It is being developed for fuel-flexible turbines burning a variety of hydrocarbon fuels, biomass gases, and refinery gases. The adaptation of the LSI to accept H{sub 2} flames is guided by an analytical expression derived from the flow field characteristics and the turbulent flame speed correlation. The evaluation of the operating regimes of nine LSI configurations for H{sub 2} shows an optimum swirl number of 0.51, which is slightly lower than the swirl number of 0.54 for the hydrocarbon LSI. Using particle image velocimetry (PIV), the flow fields of 32 premixed H{sub 2}-air and H{sub 2}-N{sub 2}-air flames were measured. The turbulent flame speeds deduced from PIV show a linear correlation with turbulence intensity. The correlation constant for H{sub 2} is 3.1 and is higher than the 2.14 value for hydrocarbons. The analysis of velocity profiles confirms that the near field flow features of the H{sub 2} flames are self-similar. These results demonstrate that the basic LSI mechanism is not affected by the differences in the properties of H{sub 2} and hydrocarbon flames and support the feasibility of the LSI concept for hydrogen fueled gas turbines.

20 FOSSIL-FUELED POWER PLANTS↗

Integrated Energy-Water Planning in the Western and Texas Interconnections

While long-term regional electricity transmission planning has traditionally focused on cost, infrastructure utilization, and reliability, issues concerning the availability of water represent an emerging issue. Thermoelectric expansion must be considered in the context of competing demands from other water use sectors balanced with fresh and non-fresh water supplies subject to climate variability. An integrated Energy-Water Decision Support System (DSS) is being developed that will enable planners in the Western and Texas Interconnections to analyze the potential implications of water availability and cost for long-range transmission planning. The project brings together electric transmission planners (Western Electricity Coordinating Council and Electric Reliability Council of Texas) with western water planners (Western Governors’ Association and the Western States Water Council). This paper lays out the basic framework for this integrated Energy-Water DSS.

electricity↗

Rotational isomeric state theory applied to the stiffness prediction of an anion polymer electrolyte membrane

While the acidic polymer electrolyte membrane (PEM) Nafion® has garnered considerable attention, the active response of basic PEMs offers another realm of potential applications. For instance, the basic PEM Selemion® is currently being considered in the development of a CO2 separation prototype device to be employed in coal power plant flue gas. The mechanical integrity of this material and subsequent effects in active response in this harsh environment will become important in prototype development. A multiscale modeling approach based on rotational isomeric state theory in combination with a Monte Carlo methodology may be employed to study mechanical integrity. The approach has the potential to be adapted to address property change of any PEM in the presence of foreign species (reinforcing or poisoning), as well as temperature and hydration variations. The conformational characteristics of the Selemion® polymer chain and the cluster morphology in the polymer matrix are considered in the prediction of the stiffness of Selemion® in specific states.

01 COAL, LIGNITE, AND PEAT↗

Truncation correction for oblique filtering lines

State-of-the-art filtered backprojection (FBP) algorithms often define the filtering operation to be performed along oblique filtering lines in the detector. A limited scan field of view leads to the truncation of those filtering lines, which causes artifacts in the final reconstructed volume. In contrast to the case where filtering is performed solely along the detector rows, no methods are available for the case of oblique filtering lines. In this work, the authors present two novel truncation correction methods which effectively handle data truncation in this case. Method 1 (basic approach) handles data truncation in two successive preprocessing steps by applying a hybrid data extrapolation method, which is a combination of a water cylinder extrapolation and a Gaussian extrapolation. It is independent of any specific reconstruction algorithm. Method 2 (kink approach) uses similar concepts for data extrapolation as the basic approach but needs to be integrated into the reconstruction algorithm. Experiments are presented from simulated data of the FORBILD head phantom, acquired along a partial-circle-plus-arc trajectory. The theoretically exact M-line algorithm is used for reconstruction. Although the discussion is focused on theoretically exact algorithms, the proposed truncation correction methods can be applied to any FBP algorithm that exposes oblique filtering lines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-43: Analytical Model for Photon Peripheral Dose in Radiotherapy Treatments

Purpose: The higher survival rate of radiotherapy patients entails a growing concern on second cancers associated to peripheral doses. Currently, dosimetry of out-of field doses is still under development. Our group has developed a methodology to estimate neutron equivalent dose in organs (1,2). We aimed to propose a model to estimate out-of-field photon doses in isocentric treatments from basic clinical data. Methods: The proposed function models the dose as the sum of leakage and scatter terms. The latter is modeled as a virtual source at the collimator, which suffers from attenuation in air and tissue, corrected by the inverse-square-law. The model was parameterized using experimental measurements with TLD700 chips placed inside an anthropomorphic phantom (6–18MV) irradiated with conformal and modulated techniques in Elekta, Siemens and Varian linacs. This model provides photon dose at a point as a function of clinical parameters as prescription dose/UM, PTV volume, distance to the field edge, height of the MLC leaves and distance from the the MLC to the isocenter. Model was tested against independent measurements (TLD100) for a VMAT treatment on a Elekta. Dose to organs is modeled from dose to points along the head-to-feet axis of the organ of a “standard man” escalated by patient height. Results: Our semi-empirical model depends on 3 given parameters (leakage parameter can be individualized). A novelty of our model, over other models (e.g., PERIDOSE), arises from its applicability to any technique (independently of the number of MU needed to deliver a dose). Differences between predictions and measurements were < 0.005mSv/UM. Conclusion: We have proposed a unique model which successfully account for photon peripheral organ dose. This model can be applied in the day-to-day clinic as it only needs a few basic parameters which are readily accessible.1. Radiother. Oncol. 107:234–243, 2013. 2. Phys. Med. Biol. 57:6167–6191, 2012.

60 APPLIED LIFE SCIENCES↗

SU-E-T-641: Development and Verification of Automatic Reading Dose of Interest From Eclipse's DVH

Purpose: According to clinical and research requirement, we develop a function of automatic reading dose of interest from dose volume histogram(DVH), to replace the traditional method with a mouse one by one point, and it's also verified. Methods: The DVH automatic reading function will be developed in an in-house developed radiotherapy information management system(RTIMS), which is based on Apache+PHP+MySQL. A DVH ASCII file is exported from Varian Eclipse V8.6, which includes the following contents: 1. basic information of patient; 2. dose information of plan; 3. dose information of structures, including basic information and dose volume data of target volume and organ at risk. And the default exported dose volume data also includes relative doses by 1% step and corresponding absolute doses and cumulative relative volumes, and the volumes are 4 decimal fraction. Clinically, we often need read the doses of some integer percent volumes, such as D50 and D30. So it couldn't be directly obtained from the above data, but we can use linear interpolation bye the near volumes and doses: Dx=D2−(V2−Vx)*(D2−D1)/(V2−V1), and program a function to search, read and calculate the corresponding data. And the doses of all preseted volume of interest of all structures can be automatically read one by one patient, and saved as a CSV file. To verify it, we select 24 IMRT plans for prostate cancer, and doses of interest are PTV D98/D95/D5/D2, bladder D30/D50, and rectum D25/D50. Two groups of data, using the automatic reading method(ARM) and pointed dose method(PDM), are analyzed with SPSS 16. The absolute difference=D-ARM-D-PDM, relative difference=absolute difference*100%/prescription dose(7600cGy). Results: The differences are as following: PTV D98/D95/D5/D2: −0.04%/− 0.04%/0.13%/0.19%, bladder D30/D50: −0.02%/0.01%, and rectum D25/D50: 0.03%/0.01%. Conclusion: Using this function, the error is very small, and can be neglected. It could greatly improve the efficiency of clinical work. Project supported by the National Natural Science Foundation of China (Grant No.81101694)

60 APPLIED LIFE SCIENCES↗

MO-G-9A-01: Imaging Refresher for Standard of Care Radiation Therapy

Imaging techniques and technology which were previously the domain of diagnostic medicine are becoming increasingly integrated and utilized in radiation therapy (RT) clinical practice. As such, there are a number of specific imaging topics that are highly applicable to modern radiation therapy physics. As imaging becomes more widely integrated into standard clinical radiation oncology practice, the impetus is on RT physicists to be informed and up-to-date on those imaging modalities relevant to the design and delivery of therapeutic radiation treatments. For example, knowing that, for a given situation, a fluid attenuated inversion recovery (FLAIR) image set is most likely what the physician would like to import and contour is helpful, but may not be sufficient to providing the best quality of care. Understanding the physics of how that pulse sequence works and why it is used could help assess its utility and determine if it is the optimal sequence for aiding in that specific clinical situation. It is thus important that clinical medical physicists be able to understand and explain the physics behind the imaging techniques used in all aspects of clinical radiation oncology practice. This session will provide the basic physics for a variety of imaging modalities for applications that are highly relevant to radiation oncology practice: computed tomography (CT) (including kV, MV, cone beam CT [CBCT], and 4DCT), positron emission tomography (PET)/CT, magnetic resonance imaging (MRI), and imaging specific to brachytherapy (including ultrasound and some brachytherapy specific topics in MR). For each unique modality, the image formation process will be reviewed, trade-offs between image quality and other factors (e.g. imaging time or radiation dose) will be clarified, and typically used cases for each modality will be introduced. The current and near-future uses of these modalities and techniques in radiation oncology clinical practice will also be discussed. Learning Objectives: To review the basic physical science principles of CT, PET, MR, and ultrasound imaging. To understand how the images are created, and present their specific role in patient management and treatment planning for therapeutic radiation (both external beam and brachytherapy). To discuss when and how each specific imaging modality is currently used in clinical practice, as well as how they may come to be used in the near future.

60 APPLIED LIFE SCIENCES↗

TU-A-19A-01: Image Registration I: Deformable Image Registration, Contour Propagation and Dose Mapping: 101 and 201

Deformable image registration, contour propagation and dose mapping have become common, possibly essential tools for modern image-guided radiation therapy. Historically, these tools have been largely developed at academic medical centers and used in a rather limited and well controlled fashion. Today these tools are now available to the radiotherapy community at large, both as stand-alone applications and as integrated components of both treatment planning and treatment delivery systems. Unfortunately, the details of how these tools work and their limitations are not generally documented or described by the vendors that provide them. Although “it looks right”, determining that unphysical deformations may have occurred is crucial. Because of this, understanding how and when to use, and not use these tools to support everyday clinical decisions is far from straight forward. The goal of this session will be to present both the theory (basic and advanced) and practical clinical use of deformable image registration, contour propagation and dose mapping. To the extent possible, the “secret sauce” that different vendor use to produce reasonable/acceptable results will be described. A detailed explanation of the possible sources of errors and actual examples of these will be presented. Knowing the underlying principles of the process and understanding the confounding factors will help the practicing medical physicist be better able to make decisions (about making decisions) using these tools available. Learning Objectives: Understand the basic (101) and advanced (201) principles of deformable image registration, contour propagation and dose mapping data mapping. Understand the sources and impact of errors in registration and data mapping and the methods for evaluating the performance of these tools. Understand the clinical use and value of these tools, especially when used as a “black box”.

60 APPLIED LIFE SCIENCES↗

TU-B-19A-01: Image Registration II: TG132-Quality Assurance for Image Registration

AAPM Task Group 132 was charged with a review of the current approaches and solutions for image registration in radiotherapy and to provide recommendations for quality assurance and quality control of these clinical processes. As the results of image registration are always used as the input of another process for planning or delivery, it is important for the user to understand and document the uncertainty associate with the algorithm in general and the Result of a specific registration. The recommendations of this task group, which at the time of abstract submission are currently being reviewed by the AAPM, include the following components. The user should understand the basic image registration techniques and methods of visualizing image fusion. The disclosure of basic components of the image registration by commercial vendors is critical in this respect. The physicists should perform end-to-end tests of imaging, registration, and planning/treatment systems if image registration is performed on a stand-alone system. A comprehensive commissioning process should be performed and documented by the physicist prior to clinical use of the system. As documentation is important to the safe implementation of this process, a request and report system should be integrated into the clinical workflow. Finally, a patient specific QA practice should be established for efficient evaluation of image registration results. The implementation of these recommendations will be described and illustrated during this educational session. Learning Objectives: Highlight the importance of understanding the image registration techniques used in their clinic. Describe the end-to-end tests needed for stand-alone registration systems. Illustrate a comprehensive commissioning program using both phantom data and clinical images. Describe a request and report system to ensure communication and documentation. Demonstrate an clinically-efficient patient QA practice for efficient evaluation of image registration.

60 APPLIED LIFE SCIENCES↗

TH-D-16A-01: Medical Physics Workshop: Editorial Vision and Guidance On Writing and Reviewing Papers

On January 1, 2014, editorial leadership of Medical Physics passed from esteemed long-time Editor Bill Hendee to a collective editorial group composed of the three presenters listed above. In this presentation, we would like to outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. Vision for Medical Physics and current initiatives: Jeff Williamson, Editor-in-Chief We cannot improve on Dr. Hendee's succinct vision statement “to continue the Journal's tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be s the preeminent forum for electronic exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; or (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities we face are: are electronic-only and open access publishing; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. To address these issues over the next 3 years, we have reduced the size of our Editorial Board and focused its efforts on improving the Journal's impact through 4 working groups (WGs): WG-1: Review process quality and selectivity Creation of 120 member Board of Associate Editors to improve review uniformity by placing Ms. management in fewer hands New reviewer guidelines and templates Answer: “what is the scope of medical physics research?” Recursive taxonomy for tagging review expertise and article contents WG-2 Improving reader experience Redesigning http://MedPhys.org to host interactive features and gateway to electronic issue archive Experimentation with interactive features beginning with “Point/Counterpoint” Data mining and Journal quality evaluation Find out who are audiences are Identify characteristics of high impact articles Measure effectiveness of innovations Outreach to related communities Special issues presenting high-impact work in designated subcommunities Addressing the needs of new research constituencies: engineers, biophysicists, clinicians Guidelines and templates for reviewers and associate editors: Shiva Das, Therapy Physics Editor We will discuss the Med. Phys. review process and a new initiative to create review templates that attempts to address current shortcomings. Template design is informed by the literature on of the review process effectiveness and practices of other journals. Its goals are to provide authors more constructive criticism to improve the manuscript; quantifying perceived importance and potential impact; and providing structured sections that prompt the reviewer to addresses important technical and editorial elements. While the template is recommended to be used, reviewers could alternatively enter their comments in the older free-form style. The expectations of the template are that it will enable consistently thorough, high quality reviews that accurately separate acceptable vs. substandard submissions but continue our tradition of helping authors to enhance papers with high potential. Ultimately, the goal is to reduce variability and subjectivity in the peer-review process, in turn leading to articles with higher research and clinical impact. We will also discuss interesting perspectives from several journals on aspects of the peer-review process such as public input via comments, influence of author-suggested reviewers, and bias in reviewer selection. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics Ms. must include a clear and concise statement of the novelty and clinical and/or scientific importance of their work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; or first demonstration that an existing engineering solution solves a clinical problem. Authors must also include: sufficient background information and rationale; enough detail that the work can be reproduced by others; sufficient statistical analysis to refute or validate their hypothesis, how it compares to; is distinct from, and improves upon others' work; and the limitations of their study. When the authors receive critiques from the referees and associate editor, the authors should provide a detailed point-bypoint response to each comment. We now ask that the authors' rebuttal include the text of the original criticism, the authors' response, and the modified text along with the line numbers in the revised article. We also ask that the new text be highlighted in a different font color in the revised submission. These changes and others will be discussed. Their purpose is to facilitate the review process.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The Octavius1500 2D ion chamber array and its associated phantoms: Dosimetric characterization of a new prototype

Purpose: The purpose of the study is to characterize the prototype of the new Octavius1500 (PTW, Freiburg, Germany) 2D ion chamber array, covering its use in different phantom setups, from the most basic solid water sandwich setup to the more complex cylindrical Octavius{sup ®} 4D (Oct4D) (PTW) phantom/detector combination. The new detector houses nearly twice the amount of ion chambers as its predecessors (Seven29 and Octavius729), thereby tackling one of the most important limitations of ion chamber (or diode) arrays, namely the limited detector density. The 0.06 cm{sup 3} cubic ion chambers are now arranged in a checkerboard pattern, leaving no lines (neither longitudinally nor laterally) without detectors. Methods: All measurements were performed on a dual energy (6 MV and 18 MV) iX Clinac (Varian Medical Systems, Palo Alto, CA) and all calculations were done in the Eclipse treatment planning system (Varian) with the Anisotropic Analytical Algorithm. First, the basic characteristics of the 2D array, such as measurement stability, dose rate dependence and dose linearity were investigated in the solid water sandwich setup. Second, the directional dependence was assessed to allow the evaluation of the new Octavius2D phantom (Oct2D{sup 1500}) for planar verification measurements of composite plans. Third, measurements were performed in the Oct4D phantom to evaluate the impact of the increased detector density on the accuracy of the volumetric dose reconstruction. Results: While showing equally good dose linearity and dose rate independence, the Octavius1500 outperforms the previous models because of its instantaneous measurement stability and its twofold active area coverage. Orthogonal field-by-field measurements immediately benefit from the increased detector density. The 3.9 cm wide compensation cavity in the new Oct2D{sup 1500} phantom prototype adequately corrects for directional dependence from the rear, resulting in good agreement within the target dose. Discrepancies may arise towards the sides of the array because of uncompensated lateral beam incidence. The beneficial impact of the detector density is most prominent in the Oct4D system, for which the average pass rate (PR) is now nearly 100% (99.31 ± 0.37) when using gamma criteria of 2%G,2 mm (10% dose threshold). In search of gamma analysis criteria that are not too lenient to detect possibly relevant deviations, the authors conclude that for our radiotherapy environment, the authors choose to adopt 3%L,3 mm PR97% (threshold 10%) criteria for the Oct2D{sup 1500}/Octavius1500 system and 2%L,3 mm PR97% (threshold 10%) for the Oct4D/Octavius1500 system. These are first line pass/check criteria and plans that fail are not necessarily rejected, but submitted to a more detailed investigation. Conclusions: When irradiated from the front, the Octavius1500 array has two main advantages over its 729 predecessors: its instantaneous measurement stability and-–most importantly—its twofold detector density. In the Oct2D1500 phantom, these advantages are counterbalanced by the more pronounced directional dependence. The measurement-based 3D dose reconstruction in the Oct4D system, however, benefits considerably from the higher detector density in the checkerboard panel design.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-179: Clinical Impact of IMRT Failure Modes at Or Near TG-142 Tolerance Criteria Levels

Purpose: Quantitatively assess the clinical impact of 11 critical IMRT dose delivery failure modes. Methods: Eleven step-and-shoot IMRT failure modes (FMs) were introduced into twelve Pinnacle v9.8 treatment plans. One standard and one highly modulated plan on the IROC IMRT phantom and ten previous H&N patient treatment plans were used. FMs included physics components covered by basic QA near tolerance criteria levels (TG-142) such as beam energy, MLC positioning, and MLC modeling. Resultant DVHs were compared to those of failure-free plans and the severity of plan degradation was assessed considering PTV coverage and OAR and normal tissue tolerances and used for FMEA severity scoring. Six of these FMs were physically simulated and phantom irradiations performed. TLD and radiochromic film results are used for comparison to treatment planning studies. Results: Based on treatment planning studies, the largest clinical impact from the phantom cases was induced by 2 mm systematic MLC shift in one bank with the combination of a D95% target under dose near 16% and OAR overdose near 8%. Cord overdoses of 5%–11% occurred with gantry angle, collimator angle, couch angle, MLC leaf end modeling, and MLC transmission and leakage modeling FMs. PTV coverage and/or OAR sparing was compromised in all FMs introduced in phantom plans with the exception of CT number to electron density tables, MU linearity, and MLC tongue-and-groove modeling. Physical measurements did not entirely agree with treatment planning results. For example, symmetry errors resulted in the largest physically measured discrepancies of up to 3% in the PTVs while a maximum of 0.5% deviation was seen in the treatment planning studies. Patient treatment plan study results are under analysis. Conclusion: Even in the simplistic anatomy of the IROC phantom, some basic physics FMs, just outside of TG-142 tolerance criteria, appear to have the potential for large clinical implications.

60 APPLIED LIFE SCIENCES↗

SU-E-T-662: Quick and Efficient Daily QA for Compact PBS Proton Therapy Machine

Purpose: As proton therapy machines become widespread the need for a quick simple routine daily QA like that for linear accelerators becomes more important. Willis-Knighton has developed an accurate and efficient daily QA that can be performed in 15 minutes. Methods: A holder for a 2D ionization chamber array (MatriXX PT) was created that is indexed to the couch to allow for quick setup, lasers accuracy with respect to beam isocenter, and couch reproducibility. Image position/reposition was performed to check Isocentricity accuracy by placing BBs on the MatriXX. The couch coordinates are compared to that of commissioning. Laser positions were confirmed with the MatriXX isocenter. After IGRT, three beams were separately delivered according to setup. For the first beam, range shifter was inserted and dose at R90, field size, flatness and symmetry in X and Y direction was measured. R90 was used so any minor changes in the range shifter can be detected. For the open beam, dose at center of SOBP, flatness and symmetry in X and Y direction was measured. Field size was measured in ±X and ±Y direction at FWHM. This is measured so any variation in spot size will be detected. For the third beam additional solid water was added and dose at R50 was measured so that any variation in beam energy will be detected. Basic mechanical and safety checks were also performed. Results: Medical physicists were able to complete the daily QA and reduce the time by half to two-third from initial daily QA procedure. All the values measured were within tolerance of that of the baseline which was established from water tank and initial MatriXX measurements. Conclusion: The change in daily QA procedure resulted in quick and easy setup and was able to measure all the basic functionality of the proton therapy PBS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-A-213-00: Economics Update

The purpose of this session is to introduce attendees to the healthcare reimbursement system and how it applies to the clinical work of a Medical Physicist. This will include general information about the different categories of payers and payees, how work is described by CPT© codes, and how various payers set values for this work in different clinical settings. 2015 is a year of significant changes to the payment system. Many CPT© codes have been deleted and replaced with new CPT© codes. These codes define some of the most common work performed in our clinics including treatment planning and delivery. This presentation will describe what work is encompassed in these codes and will give attendees an overview of the changes for 2015 as they apply to radiation oncology. Finally, some insight into what can be expected during 2016 will be presented. This includes what information is typically released by the Centers for Medicaid & Medicare Services (CMS) during the year and how we as an organization respond. This will include ways members can interact with the AAPM professional economics committee and other resources members may find helpful. Learning Objectives: Basics of how Medicare is structured and how reimbursement rates are set. Basic understanding of proposed changes to the 2016 Medicare rules. What resources are available from the AAPM and how to interact with the professional economics committee. Ownership in pxAlpha, LLC, a medical device start up company.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MO-A-213-01: 2015 Economics Update Part 1

The purpose of this session is to introduce attendees to the healthcare reimbursement system and how it applies to the clinical work of a Medical Physicist. This will include general information about the different categories of payers and payees, how work is described by CPT© codes, and how various payers set values for this work in different clinical settings. 2015 is a year of significant changes to the payment system. Many CPT© codes have been deleted and replaced with new CPT© codes. These codes define some of the most common work performed in our clinics including treatment planning and delivery. This presentation will describe what work is encompassed in these codes and will give attendees an overview of the changes for 2015 as they apply to radiation oncology. Finally, some insight into what can be expected during 2016 will be presented. This includes what information is typically released by the Centers for Medicaid & Medicare Services (CMS) during the year and how we as an organization respond. This will include ways members can interact with the AAPM professional economics committee and other resources members may find helpful. Learning Objectives: Basics of how Medicare is structured and how reimbursement rates are set. Basic understanding of proposed changes to the 2016 Medicare rules. What resources are available from the AAPM and how to interact with the professional economics committee. Ownership in pxAlpha, LLC, a medical device start up company.

61 RADIATION PROTECTION AND DOSIMETRY↗