Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cancer models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

The contribution of c-Jun N-terminal kinase activation and subsequent Bcl-2 phosphorylation to apoptosis induction in human B-cells is dependent on the mode of action of specific stresses

The c-Jun N-terminal kinase (JNK) pathway can play paradoxical roles as either a pro-survival or a pro-cell death pathway depending on type of stress and cell type. The goal of the present study was to determine the role of JNK pathway signaling for regulating B-cell apoptosis in two important but contrasting situations-global proteotoxic damage, induced by arsenite and hyperthermia, versus specific microtubule inhibition, induced by the anti-cancer drug vincristine, using the EW36 B-cell line. This cell line over-expresses the Bcl-2 protein and is a useful model to identify treatments that can overcome multi-drug resistance in lymphoid cells. Exposure of EW36 B-cells to arsenite or lethal hyperthermia resulted in activation of the JNK pathway and induction of apoptosis. However, pharmacological inhibition of the JNK pathway did not inhibit apoptosis, indicating that JNK pathway activation is not required for apoptosis induction by these treatments. In contrast, vincristine treatment of EW36 B-cells resulted in JNK activation and apoptosis that was suppressed by JNK inhibition. A critical difference between the two types of stress treatments was that only vincristine-induced JNK activation resulted in phosphorylation of Bcl-2 at threonine-56, a modification that can block its anti-apoptotic function. Importantly, Bcl-2 phosphorylation was attenuated by JNK inhibition implicating JNK as the upstream kinase. Furthermore, arsenite and hyperthermia treatments activated a p53/p21 pathway associated with apoptosis induction, whereas vincristine did not activate this pathway. These results reveal two stress-activated pathways, one JNK-dependent and another JNK-independent, either of which can bypass Bcl-2 mediated resistance, resulting in cell death.

60 APPLIED LIFE SCIENCES↗

Design and Discovery of N -(2-Methyl-5'-morpholino-6'-((tetrahydro-2 H -pyran-4-yl)oxy)-[3,3'-bipyridin]-5-yl)-3-(trifluoromethyl)benzamide (RAF709): A Potent, Selective, and Efficacious RAF Inhibitor Targeting RAS Mutant Cancers

RAS oncogenes have been implicated in >30% of human cancers, all representing high unmet medical need. The exquisite dependency on CRAF kinase in KRAS mutant tumors has been established in genetically engineered mouse models and human tumor cells. To date, many small molecule approaches are under investigation to target CRAF, yet kinase-selective and cellular potent inhibitors remain challenging to identify. Herein, we describe 14 (RAF709) [Aversa, Biaryl amide compounds as kinase inhibitors and their preparation. WO 2014151616, 2014], a selective B/C RAF inhibitor, which was developed through a hypothesis-driven approach focusing on drug-like properties. A key challenge encountered in the medicinal chemistry campaign was maintaining a balance between good solubility and potent cellular activity (suppression of pMEK and proliferation) in KRAS mutant tumor cell lines. We investigated the small molecule crystal structure of lead molecule 7 and hypothesized that disruption of the crystal packing would improve solubility, which led to a change from N-methylpyridone to a tetrahydropyranyl oxy-pyridine derivative. 14 proved to be soluble, kinase selective, and efficacious in a KRAS mutant xenograft model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Bayesian supervised domain adaptation for RNA sequencing data

Abstract Motivation When learning to subtype complex disease based on next-generation sequencing data, the amount of available data is often limited. Recent works have tried to leverage data from other domains to design better predictors in the target domain of interest with varying degrees of success. But they are either limited to the cases requiring the outcome label correspondence across domains or cannot leverage the label information at all. Moreover, the existing methods cannot usually benefit from other information available a priori such as gene interaction networks. Results In this article, we develop a generative optimal Bayesian supervised domain adaptation (OBSDA) model that can integrate RNA sequencing (RNA-Seq) data from different domains along with their labels for improving prediction accuracy in the target domain. Our model can be applied in cases where different domains share the same labels or have different ones. OBSDA is based on a hierarchical Bayesian negative binomial model with parameter factorization, for which the optimal predictor can be derived by marginalization of likelihood over the posterior of the parameters. We first provide an efficient Gibbs sampler for parameter inference in OBSDA. Then, we leverage the gene-gene network prior information and construct an informed and flexible variational family to infer the posterior distributions of model parameters. Comprehensive experiments on real-world RNA-Seq data demonstrate the superior performance of OBSDA, in terms of accuracy in identifying cancer subtypes by utilizing data from different domains. Moreover, we show that by taking advantage of the prior network information we can further improve the performance. Availability and implementation The source code for implementations of OBSDA and SI-OBSDA are available at the following link. https://github.com/SHBLK/BSDA. Supplementary information Supplementary data are available at Bioinformatics online.

Biochemistry & Molecular Biology↗

The correlation of tissue motion within the lung: implications on fiducial based treatments

In radiation therapy many motion management and alignment techniques rely on the accuracy of an internal fiducial acting as a surrogate for target motion within the lung. Although fiducials are routinely used as surrogates for tumor motion, the extent to which varying spatial locations in the lung move similarly to other locations has yet to be quantitatively analyzed. In an attempt to analyze the motion correlation throughout the lung, ten primary lung cancer patients underwent IRB-approved 4DCT scans in the supine position. Deformable registration produced motion vectors for each voxel between exhalation and inhalation. Modeling was performed for each vector and all surrounding vectors within the lung in order to determine the mean 3D Euclidean distance necessary for an implanted fiducial to correlate with surrounding tissue motion to within 3 mm (left lower: 1.7 cm, left upper: 2.1 cm, right lower 1.6 cm, and right upper 2.9 cm). No general implantation rule of where to position a fiducial with respect to the tumor was found as the motion is highly patient and lobe specific. Correlation maps are presented showcasing spatial anisotropy of the motion of tissue surrounding the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-54: Effective Dose and Radiation Cancer Risks for Scoliosis Patients Undergoing Full Spine Radiography

Purpose: Scoliotic patients underwent a lot of radiologic examinations during the control and treatment periods. This study used the PCXMC program to calculate the effective dose of the patients and assess the radiation cancer risks. Methods: Seventy five scoliotic patients were examined using CR or DR systems during the control and treatment periods in Chang Gung Memorial Hospital. The technical factors were recorded for each patient during his/her control and treatment period. The entrance surface dose was measured using thermoluminence dosimeters and derived from technical factors and irradiated geometry. The effective dose of patients and relative radiation cancer risks were calculated by the PCXMC program. All required information regarding patient age and sex, the x-ray spectra, and the tube voltage and current were registered. The radiation risk were estimated using the model developed by the BEIR VII committee (2006). Results: The effective doses of full spine radiography with anteroposterior and lateral projections were 0.626 mSv for patients using DR systems, and 0.483mSv for patients using CR systems, respectively. The dose using DR system was 29.6% higher than those using CR system. The maximum organ dose was observed in the breast for both projections in all the systems. The risk of exposure—induced cancer death (REID) of patients for DR and CR systems were 0.009% and 0.007%, respectively. Conclusion: The risk estimates were regarded with healthy skepticism, placed more emphasis on the magnitude of the risk. The effective doses estimated in this study could be served as a reference for radiologists and technologists and demonstrate the necessity to optimize patient protection for full spine radiography though the effective doses are not at the level to induce deterministic effects and not significant in the stochastic effect. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1D0421)

60 APPLIED LIFE SCIENCES↗

Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations

Purpose: A dose calculation tool, which combines the accuracy of the dose planning method (DPM) Monte Carlo code and the versatility of a practical analytical multisource model, which was previously reported has been improved and validated for the Varian 6 and 10 MV linear accelerators (linacs). The calculation tool can be used to calculate doses in advanced clinical application studies. One shortcoming of current clinical trials that report dose from patient plans is the lack of a standardized dose calculation methodology. Because commercial treatment planning systems (TPSs) have their own dose calculation algorithms and the clinical trial participant who uses these systems is responsible for commissioning the beam model, variation exists in the reported calculated dose distributions. Today’s modern linac is manufactured to tight specifications so that variability within a linac model is quite low. The expectation is that a single dose calculation tool for a specific linac model can be used to accurately recalculate dose from patient plans that have been submitted to the clinical trial community from any institution. The calculation tool would provide for a more meaningful outcome analysis. Methods: The analytical source model was described by a primary point source, a secondary extra-focal source, and a contaminant electron source. Off-axis energy softening and fluence effects were also included. The additions of hyperbolic functions have been incorporated into the model to correct for the changes in output and in electron contamination with field size. A multileaf collimator (MLC) model is included to facilitate phantom and patient dose calculations. An offset to the MLC leaf positions was used to correct for the rudimentary assumed primary point source. Results: Dose calculations of the depth dose and profiles for field sizes 4 × 4 to 40 × 40 cm agree with measurement within 2% of the maximum dose or 2 mm distance to agreement (DTA) for 95% of the data points tested. The model was capable of predicting the depth of the maximum dose within 1 mm. Anthropomorphic phantom benchmark testing of modulated and patterned MLCs treatment plans showed agreement to measurement within 3% in target regions using thermoluminescent dosimeters (TLD). Using radiochromic film normalized to TLD, a gamma criteria of 3% of maximum dose and 2 mm DTA was applied with a pass rate of least 85% in the high dose, high gradient, and low dose regions. Finally, recalculations of patient plans using DPM showed good agreement relative to a commercial TPS when comparing dose volume histograms and 2D dose distributions. Conclusions: A unique analytical source model coupled to the dose planning method Monte Carlo dose calculation code has been modified and validated using basic beam data and anthropomorphic phantom measurement. While this tool can be applied in general use for a particular linac model, specifically it was developed to provide a singular methodology to independently assess treatment plan dose distributions from those clinical institutions participating in National Cancer Institute trials.

60 APPLIED LIFE SCIENCES↗

Role of Dendritic Cells in Immune Dysfunction

Specific aims include: (1) Application of the bioreactor to enhance cytokine-regulated proliferation and maturation of dendritic cells (DC); (2) Based on clues from spaceflight: compare the frequency and function of DC in normal donors and immunocompromised cancer patients; and (3) Initiate studies on the efficiency of cytokine therapy and DC-assisted immunotherapy (using bioreactor-expanded DC) in animal models of experimental fungal infections.

Savary, Cherylyn A.↗

Immune function during space flight

It is very likely that the human immune system will be altered in astronauts exposed to the conditions of long-term space flight: isolation, containment, microgravity, radiation, microbial contamination, sleep disruption, and insufficient nutrition. In human and animal subjects flown in space, there is evidence of immune compromise, reactivation of latent virus infection, and possible development of a premalignant or malignant condition. Moreover, in ground-based space flight model investigations, there is evidence of immune compromise and reactivation of latent virus infection. All of these observations in space flight itself or in ground-based models of space flight have a strong resonance in a wealth of human pathologic conditions involving the immune system where reactivated virus infections and cancer appear as natural consequences. The clinical conditions of Epstein-Barr-driven lymphomas in transplant patients and Kaposi's sarcoma in patients with autoimmune deficiency virus come easily to mind in trying to identify these conditions. With these thoughts in mind, it is highly appropriate, indeed imperative, that careful investigations of human immunity, infection, and cancer be made by space flight researchers.

manned↗

Knockdown of astrocyte elevated gene-1 inhibits tumor growth and modifies microRNAs expression profiles in human colorectal cancer cells

Highlights: • AEG-1 expression in CRC cell lines and down-regulation or upregulation of AEG-1 in vitro. • Knockdown of AEG-1 inhibits cell proliferation, colony formation and invasion. • Upregulation of AEG-1 enhances proliferation, invasion and colony formation. • Knockdown of AEG-1 accumulates G0/G1-phase cells and promotes apoptosis in CRC cells. • AEG-1 knockdown increases 5-FU cytotoxicity. - Abstract: Astrocyte elevated gene-1 (AEG-1), upregulated in various types of malignancies including colorectal cancer (CRC), has been reported to be associated with the carcinogenesis. MicroRNAs (miRNAs) are widely involved in the initiation and progression of cancer. However, the functional significance of AEG-1 and the relationship between AEG-1 and microRNAs in human CRC remains unclear. The aim of this study was to investigate whether AEG-1 could serve as a potential therapeutic target of human CRC and its possible mechanism. We adopted a strategy of ectopic overexpression or RNA interference to upregulate or downregulate expression of AEG-1 in CRC models. Their phenotypic changes were analyzed by Western blot, MTT and transwell matrix penetration assays. MicroRNAs expression profiles were performed using microarray analysis followed by validation using qRT-PCR. Knockdown of AEG-1 could significantly inhibit colon cancer cell proliferation, colony formation, invasion and promotes apoptosis. Conversely, upregulation of AEG-1 could significantly enhance cell proliferation, invasion and reduced apoptisis. AEG-1 directly contributes to resistance to chemotherapeutic drug. Targeted downregulation of AEG-1 might improve the expression of miR-181a-2{sup ∗}, -193b and -193a, and inversely inhibit miR-31 and -9{sup ∗}. Targeted inhibition of AEG-1 can lead to modification of key elemental characteristics, such as miRNAs, which may become a potential effective therapeutic strategy for CRC.

60 APPLIED LIFE SCIENCES↗

An unsteady flow of magnetic nanoparticles as drug carrier suspended in micropolar fluid through a porous tapered arterial stenosis under non-uniform magnetic field and periodic body acceleration

A mathematical model has been developed for pulsatile flow of blood through a tapered arterial stenosis in a porous medium under the influence of non-uniform magnetic field and periodic body acceleration treating blood as micropolar fluid carrying iron oxide nanoparticles. The governing equations of the system are solved numerically using finite difference schemes. The effects of stenotic height, taper angle, micropolar parameters, magnetic field, porosity, pulsatility, and magnetic nanoparticles on the flow of blood are analysed, and the results are represented graphically. It is significant to note that the flow parameters such as wall shear stress and flow resistance increase with increase in stenotic height, tapering parameter, magnetic field, pulsatile Reynolds number, time period, particle concentration, and particle mass parameters. Wall shear stress decreases with the increasing values of coupling number and it shows opposite behaviour in the case of flow resistance. Also increase in Darcy number leads to decrease in wall shear stress and flow resistance. The significance of treating blood as micropolar fluid is that the rotation of particles is taken into account. Cardiovascular diseases occur mainly due to abnormal blood flow in the arteries. To normalize the blood flow in the arteries, analysis of parameters involved in the study is essential. Hence, the present study has various applications in biomedical sciences. The effects of nanoparticles on blood flow analysed in the study have significant applications in delivery of drugs for treating cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Symptomatic Stroke After Radiation Therapy for Childhood Cancer: A Long-Term Follow-Up Cohort Analysis

Purpose: Long-term childhood cancer survivors are at high risk of late adverse effects, including stroke. We aimed to determine the cumulative incidence of clinically validated symptomatic stroke (transient ischemic attack [TIA], cerebral infarction, and intracerebral hemorrhage [ICH]) and to quantify dose-effect relationships for cranial radiation therapy (CRT) and supradiaphragmatic radiation therapy (SDRT). Methods and Materials: Our single-center study cohort included 1362 survivors of childhood cancer that were diagnosed between 1966 and 1996. Prescribed CRT and SDRT doses were converted into the equivalent dose in 2-Gy fractions (EQD{sub 2}). Multivariate Cox regression models were used to analyze the relationship between the EQD{sub 2} and stroke. Results: After a median latency time of 24.9 years and at a median age of 31.2 years, 28 survivors had experienced a first stroke: TIA (n=5), infarction (n=13), and ICH (n=10). At an attained age of 45 years, the estimated cumulative incidences, with death as competing risk, among survivors treated with CRT only, SDRT only, both CRT and SDRT, and neither CRT nor SDRT were, respectively, 10.0% (95% confidence interval [CI], 2.5%-17.0%), 5.4% (95% CI, 0%-17.0%), 12.5% (95% CI, 5.5%-18.9%), and 0.1% (95% CI, 0%-0.4%). Radiation at both locations significantly increased the risk of stroke in a dose-dependent manner (hazard ratios: HR{sub CRT} 1.02 Gy{sup −1}; 95% CI, 1.01-1.03, and HR{sub SDRT} 1.04 Gy{sup −1}; 95% CI, 1.02-1.05). Conclusions: Childhood cancer survivors treated with CRT, SDRT, or both have a high stroke risk. One in 8 survivors treated at both locations will have experienced a symptomatic stroke at an attained age of 45 years. Further research on the pathophysiologic processes involved in stroke in this specific group of patients is needed to enable the development of tailored secondary prevention strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Discovery and Characterization of Novel Nonsubstrate and Substrate NAMPT Inhibitors

Cancer cells are highly reliant on NAD+-dependent processes, including glucose metabolism, calcium signaling, DNA repair, and regulation of gene expression. Nicotinamide phosphoribosyltransferase (NAMPT), the rate-limiting enzyme for NAD+ salvage from nicotinamide, has been investigated as a target for anticancer therapy. Known NAMPT inhibitors with potent cell activity are composed of a nitrogen-containing aromatic group, which is phosphoribosylated by the enzyme. Here, we identified two novel types of NAM-competitive NAMPT inhibitors, only one of which contains a modifiable, aromatic nitrogen that could be a phosphoribosyl acceptor. Both types of compound effectively deplete cellular NAD+, and subsequently ATP, and produce cell death when NAMPT is inhibited in cultured cells for more than 48 hours. Careful characterization of the kinetics of NAMPT inhibition in vivo allowed us to optimize dosing to produce sufficient NAD+ depletion over time that resulted in efficacy in an HCT116 xenograft model. Our data demonstrate that direct phosphoribosylation of competitive inhibitors by the NAMPT enzyme is not required for potent in vitro cellular activity or in vivo antitumor efficacy. Mol Cancer Ther; 16(7); 1236–45.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-241: Monte Carlo Simulation Study About the Prediction of Proton-Induced DNA Strand Breakage On the Double Helix Structure

Purpose: In particle therapy and radiobiology, the investigation of mechanisms leading to the death of target cancer cells induced by ionising radiation is an active field of research. Recently, several studies based on Monte Carlo simulation codes have been initiated in order to simulate physical interactions of ionising particles at cellular scale and in DNA. Geant4-DNA is the one of them; it is an extension of the general purpose Geant4 Monte Carlo simulation toolkit for the simulation of physical interactions at sub-micrometre scale. In this study, we present Geant4-DNA Monte Carlo simulations for the prediction of DNA strand breakage using a geometrical modelling of DNA structure. Methods: For the simulation of DNA strand breakage, we developed a specific DNA geometrical structure. This structure consists of DNA components, such as the deoxynucleotide pairs, the DNA double helix, the nucleosomes and the chromatin fibre. Each component is made of water because the cross sections models currently available in Geant4-DNA for protons apply to liquid water only. Also, at the macroscopic-scale, protons were generated with various energies available for proton therapy at the National Cancer Center, obtained using validated proton beam simulations developed in previous studies. These multi-scale simulations were combined for the validation of Geant4-DNA in radiobiology. Results: In the double helix structure, the deposited energy in a strand allowed to determine direct DNA damage from physical interaction. In other words, the amount of dose and frequency of damage in microscopic geometries was related to direct radiobiological effect. Conclusion: In this report, we calculated the frequency of DNA strand breakage using Geant4- DNA physics processes for liquid water. This study is now on-going in order to develop geometries which use realistic DNA material, instead of liquid water. This will be tested as soon as cross sections for DNA material become available in Geant4-DNA.

60 APPLIED LIFE SCIENCES↗

Epidemiologic Study of One Million U.S. Radiation Workers and Veterans

The single most important question in radiation epidemiology is determining the level of health risks associated with radiation exposures that occur gradually over time. The study of one million early U.S. radiation workers and veterans has been designed to provide information on risk following chronic exposures by focusing on occupational groups with differing radiation exposure patterns, including intakes of radionuclides. The cost-efficient study builds on the investments made and foundations laid by investigators and government agencies over the past 30-40 years, which have established early worker cohorts that can now provide answers to questions on the lifetime human health risks associated with low-level radiation exposures. Within the overall goal of the epidemiologic study of one million U.S. radiation workers and veterans, this project had a total of nine specific aims which included studies of six populations for multiple endpoints including cancer overall mortality, leukemia and non-cancer mortality. The six populations included: Mound, Ohio, workers exposed to polonium, tritium and plutonium; nuclear power plant workers within the Landauer dosimetry and Nuclear Regulatory Commission data files; industrial radiographers; Mallinckrodt uranium workers; uranium workers who linked with the US Renal Data System; and nuclear weapons test participants. Over 400,000 workers and atomic veterans are included in these populations, with vital status being determined and analyses of all causes of death undertaken. A critical, integral component of the studies has been comprehensive evaluations of dosimetry involving, in many cases, complex dose reconstructions, and assessments of uncertainties. The work has also involved development of state-of-the art statistical approaches and modeling. All nine aims were accomplished successfully, resulting in publication of two NCRP documents, 13 literature papers, numerous Boice Reports in Health Physics News and many presentations of the work at scientific meetings. Furthermore, recommendations have been developed for an approach to integrate epidemiologic observations with radiation biology for risk assessment and biological models of radiation effect. The results of this project, as well as ongoing epidemiology studies of US radiation workers and veterans, are providing much-needed insights into complex issues regarding cancer and non-cancer health risks from low dose irradiation, how to apply a "dose and dose rate effectiveness factor" to scale the risks from the A-bomb survivor data to current occupational and environmental circumstances, and how to evaluate risk following intakes of radioactive substances. In addition to application to radiation workers, the results of the studies can provide guidance as society debates the role of nuclear energy and deals with nuclear waste, threats of terrorist attacks with nuclear/radiological devices, the remarkable increase in medical exposures to CT scans and nuclear imaging, and to NASA as radiation protection for astronauts on long-duration mission beyond low-Earth orbit is planned.

61 RADIATION PROTECTION AND DOSIMETRY↗

Honokiol inhibits pathological retinal neovascularization in oxygen-induced retinopathy mouse model

Highlights: •Aberrant activation of HIF pathway is the underlying cause of ischemic neovascularization. •Honokiol has better therapeutic index as a HIF inhibitor than digoxin and doxorubicin. •Daily IP injection of honokiol in OIR mouse model reduced retinal neovascularization. •Honokiol also prevents vaso-obliteration, the characteristic feature of the OIR model. •Honokiol enhanced physiological revascularization of the retinal vascular plexuses. -- Abstract: Aberrant activation of the hypoxia inducible factor (HIF) pathway is the underlying cause of retinal neovascularization, one of the most common causes of blindness worldwide. The HIF pathway also plays critical roles during tumor angiogenesis and cancer stem cell transformation. We have recently shown that honokiol is a potent inhibitor of the HIF pathway in a number of cancer and retinal pigment epithelial cell lines. Here we evaluate the safety and efficacy of honokiol, digoxin, and doxorubicin, three recently identified HIF inhibitors from natural sources. Our studies show that honokiol has a better safety to efficacy profile as a HIF inhibitor than digoxin and doxorubicin. Further, we show for the first time that daily intraperitoneal injection of honokiol starting at postnatal day (P) 12 in an oxygen-induced retinopathy (OIR) mouse model significantly reduced retinal neovascularization at P17. Administration of honokiol also prevents the oxygen-induced central retinal vaso-obliteration, characteristic feature of the OIR model. Additionally, honokiol enhanced physiological revascularization of the retinal vascular plexuses. Since honokiol suppresses multiple pathways activated by HIF, in addition to the VEGF signaling, it may provide advantages over current treatments utilizing specific VEGF antagonists for ocular neovascular diseases and cancers.

60 APPLIED LIFE SCIENCES↗

Cost-Effectiveness Analysis of Chemoradiation Therapy Versus Transoral Robotic Surgery for Human Papillomavirus–Associated, Clinical N2 Oropharyngeal Cancer

Purpose: To perform a cost-effectiveness analysis of primary chemoradiation therapy (CRT) versus transoral robotic surgery (TORS) for clinical N2, human papillomavirus (HPV)-positive oropharyngeal carcinoma. Methods and Materials: We developed a Markov model to describe the health states after treatment with CRT or TORS, followed by adjuvant radiation therapy or CRT in the presence of high-risk pathology (positive margins or extracapsular extension). Outcomes, toxicities, and costs were extracted from the literature. One-way sensitivity analyses (SA) were performed over a wide range of parameters, as were 2-way SA between the key variables. Probabilistic SA and value of information studies were performed over key parameters. Results: The expected quality-adjusted life years (QALYs)/total costs for CRT and TORS were 7.31/$50,100 and 7.29/$62,200, respectively, so that CRT dominated TORS. In SA, primary CRT was almost always cost-effective up to a societal willingness-to-pay of $200,000/QALY, unless the locoregional recurrence risk after TORS was 30% to 50% lower, at which point it became cost effective at a willingness-to-pay of $50-100,000/QALY. Probabilistic SA confirmed the importance of locoregional recurrence risk, and the value of information in precisely knowing this parameter was more than $7M per year. If the long-term utility after TORS was 0.03 lower than CRT, CRT was cost-effective over nearly any assumption. Conclusions: Under nearly all assumptions, primary CRT was the cost-effective therapy for HPV-associated, clinical N2 OPC. However, in the hypothetical event of a large relative improvement in LRR with surgery and equivalent long-term utilities, primary TORS would become the higher-value treatment, arguing for prospective, comparative study of the 2 paradigms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Pelvic Phantom for Modeling Internal Organ Motions

A pelvic phantom was developed for use in testing image-guided radiation therapy (IGRT) and adaptive applications in radiation therapy (ART) with simulating the anterior-posterior internal organ motions during prostate radiotherapy. Measurements could be done with an ionization chamber (IC) in the simulated prostate. The rectum was simulated by air-equivalent material (AEM). The volume superior to the IC placement was considered as the bladder. The extension of AEM volume could be varied. The vertical position of the IC placement could be shifted by {+-}1 cm to simulate the prostate motion parallel to the changes in bladder volume. The reality of the simulation was inspected. Three-millimeter-slice-increment computed tomography (CT) scans were taken for irradiation planning. The structure set was adapted to the phantom from a treated patient. Planning target volume was delineated according to the RTOG 0126 study. IMRT and 3D conformal radiation therapy (3D-CRT) plans were made. Prostate motion and rectum volume changes were simulated in the phantom. IC displacement was corrected by phantom shifting. The delivered dose was measured with IC in 7 cases using intensity-modulated radiation therapy (IMRT) and 3D-CRT fractions, and single square-shaped beams: anteroposterior (AP), posteroanterior (PA), and lateral (LAT). Variations from the calculated doses were slightly below 1% at IMRT and around 1% at 3D-CRT; below 4.5% at square AP beam; up to 9% at square PA beam; and around 0.5% at square LAT beam. Other authors have already shown that by using planning systems and ultrasonic and cone beam CT guidance, correction of organ motions in a real patient during prostate cancer IGRT does not have a significant dosimetric effect. The inspection of our phantom-as described here-ended with similar results. Our team suggested that our model is sufficiently realistic and can be used for IGRT and ART testing.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-278: Realization of Dose Verification Tool for IMRT Plan Based On DPM

Purpose: To build a Monte Carlo dose verification tool for IMRT Plan by implementing a irradiation source model into DPM code. Extend the ability of DPM to calculate any incident angles and irregular-inhomogeneous fields. Methods: With the virtual source and the energy spectrum which unfolded from the accelerator measurement data,combined with optimized intensity maps to calculate the dose distribution of the irradiation irregular-inhomogeneous field. The irradiation source model of accelerator was substituted by a grid-based surface source. The contour and the intensity distribution of the surface source were optimized by ARTS (Accurate/Advanced Radiotherapy System) optimization module based on the tumor configuration. The weight of the emitter was decided by the grid intensity. The direction of the emitter was decided by the combination of the virtual source and the emitter emitting position. The photon energy spectrum unfolded from the accelerator measurement data was adjusted by compensating the contaminated electron source. For verification, measured data and realistic clinical IMRT plan were compared with DPM dose calculation. Results: The regular field was verified by comparing with the measured data. It was illustrated that the differences were acceptable (<2% inside the field, 2–3mm in the penumbra). The dose calculation of irregular field by DPM simulation was also compared with that of FSPB (Finite Size Pencil Beam) and the passing rate of gamma analysis was 95.1% for peripheral lung cancer. The regular field and the irregular rotational field were all within the range of permitting error. The computing time of regular fields were less than 2h, and the test of peripheral lung cancer was 160min. Through parallel processing, the adapted DPM could complete the calculation of IMRT plan within half an hour. Conclusion: The adapted parallelized DPM code with irradiation source model is faster than classic Monte Carlo codes. Its computational accuracy and speed satisfy the clinical requirement, and it is expectable to be a Monte Carlo dose verification tool for IMRT Plan. Strategic Priority Research Program of the China Academy of Science(XDA03040000); National Natural Science Foundation of China (81101132)

60 APPLIED LIFE SCIENCES↗