Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equilibrium diffusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Phase stability of a eutectic high entropy alloy under extremes of pressures and temperatures

Additively manufactured high-entropy alloys are of interest because of their unique combination of high yield strength and large ductility achieved with far-from-equilibrium crystalline phases and micro/nanostructure morphology. We report on the phase transformation and thermal equation of state of the eutectic high-entropy alloy (EHEA) Al 18 Co 20 Cr 10 Fe 10 Ni 40 W 2 , produced by laser powder-bed fusion (L-PBF). The EHEA was studied in a large-volume Paris–Edinburgh cell using energy-dispersive x-ray diffraction to a pressure of 5.5 GPa and a temperature of 1723 K. Static compression studies in diamond anvil cells using angle-dispersive x-ray diffraction extended the high-pressure structural data to 317 GPa at ambient temperature. The initial dual-phase nanolamellar face-centered cubic (FCC) and body-centered cubic (BCC) structure of Al 18 Co 20 Cr 10 Fe 10 Ni 40 W 2 transforms into a single FCC phase under high pressure, with the BCC-to-FCC phase transformation completing at 9 ± 2 GPa. The FCC phase remained stable up to the highest pressure of 317 GPa. The measured thermal equation of state for the FCC phase of Al 18 Co 20 Cr 10 Fe 10 Ni 40 W 2 is presented up to 5.5 GPa and 1473 K. We observed melting of the EHEA at 1698 ± 25 K at a pressure of 5.5 GPa, and the recrystallized sample shows an increased fraction of the CsCl-type (B2) phase at ambient conditions following release from the high-pressure high-temperature state. The BCC-to-FCC phase transition completion pressure is correlated with the nanolamellae thickness of the BCC layer in this diffusion-less transformation at ambient temperature.

36 MATERIALS SCIENCE↗

Coupling between bulk thermal defects and surface segregation dynamics

Surface segregation is a phenomenon that depends on the delicate interplay between thermodynamic driving forces and kinetic obstacles, for which elevated temperature is often needed to enhance the atom mobility and reach equilibrium. Using the classic system of Cu 3 Au ( 100 ) under nonisothermal conditions, in this study, we show an adatom process underlying transient surface segregation dynamics through the temperature-change-driven creation and annihilation of thermal vacancies in the bulk and the resulting bulk-surface mass exchanges. This is demonstrated by monitoring the surface composition evolution of Cu 3 Au ( 100 ) with temperature changes between 250 and 500 ° C , showing that the increase in temperature decreases monotonically the surface Au concentration as a result of the transfer of more Cu than Au from the bulk to the surface to form Cu-rich clusters of adatoms. Such a bulk thermal defect effect is expected to be universal in inducing the disparity in the bulk-surface mass exchanges of dissimilar atoms in multicomponent materials because of the inherent differences in the vacancy formation energies of the constituent atoms.

36 MATERIALS SCIENCE↗

Assessing factors that determine adatom migration and clustering on a thin film oxide; Pt 1 and Rh 1 on the “29” Cu x O/Cu(1 1 1) surface

The dynamical nature of single-site catalysts under non-equilibrium conditions poses significant challenges in the full characterization of their active sites. The “29” oxide is a thin Cu x O film grown on Cu(111) which provides a well-defined surface on which to study the structure and chemistry of atomically dispersed precious metals. A combination of experimental and first-principles approaches is used to investigate the factors that influence the mobility of metal adatoms and their clustering tendencies. Our work elucidates how a homogenous coordination environment of neutral single-atoms can be obtained when its tendency to break oxide bonds within its vicinity is low. Herein we demonstrate that this in turn affects the chemical atomically dispersed species on thin-film oxides, as defects on the oxide would in fact allow such species to be more accessible to CO. We thus highlight the importance of understanding the relationship between defects and atomically dispersed active sites upon designing single-site catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial exploration of growth of InN by electrochemical solution growth.

This report summarizes a brief and unsuccessful attempt to grow indium nitride via the electrochemical solution growth method and a modification thereof. Described in this report is a brief effort using a $50,000 LDRD award to explore the possibilities of applying the Electrochemical Solution Growth (ESG) technique to the growth of indium nitride (InN). The ability to grow bulk InN would be exciting from a scientific perspective, and a commercial incentive lies in the potential of extending the ESG technique to grow homogeneous, bulk alloys of In{sub x}Ga{sub 1-x}N for light emitting diodes (LEDs) operating in the green region of the spectrum. Indium nitride is the most difficult of the III-nitrides to grow due to its very high equilibrium vapor pressure of nitrogen1. It is several orders of magnitude higher than for gallium nitride or aluminum nitride. InN has a bandgap energy of 0.7eV, and achieving its growth in bulk for large area, high quality substrates would permit the fabrication of LEDs operating in the infrared. By alloying with GaN and AlN, the bulk material used as substrates would enable high efficiency emission wavelengths that could be tailored all the way through the deep ultraviolet. In addition, InN has been shown to have very high electronic mobilities (2700 cm{sup 2}/V s), making it a promising material for transistors and even terahertz emitters. Several attempts at synthesizing InN have been made by several groups. It was shown that metallic indium does not interact with unactivated nitrogen even at very high temperatures. Thus sets up an incompatibility between the precursors in all growth methods: a tradeoff between thermally activating the nitrogen-containing precursor and the low decomposition temperature of solid InN. We have been working to develop a novel growth technique that circumvents the difficulties of other bulk growth techniques by precipitating the column III nitrides from a solvent, such as a molten chloride salt, that provides an excellent host environment for the gallium nitride and indium nitride precursors. In particular, we have found that molten halide salts can solubilize both gallium (Ga{sup 3+}) and nitride (N{sup 3-}) ions without reacting with them to the extent that they are no longer available for reaction with each other. Literature reports indicate measured nitride ion concentrations in LiCl at 650 C as high as 10 mol% - a sufficient concentration to yield growth rates on the order of 0.1 to {approx}1 mm/hr under diffusion-limited growth conditions. Also, molten salts are compatible with the 400-1200 C temperatures likely to be necessary for growth of high-quality single-crystal III-nitrides. Since they can be worked with at (or close to) atmospheric pressure, scalability is not a problem and manufacturability issues are thus minimized, including capital equipment costs. Although the III-nitrides cannot be float-zone refined to remove impurities due to their high melting temperatures and vapor pressures, the salts can be, thus reducing sources of impurities before growth begins. Finally, the molten salts offer a number of pathways to improve the solubility and control the growth of the III-nitrides by functioning as an electrolyte in electrochemical processes. We have already demonstrated growth of wurtzite GaN particles ranging from 0.2 to 0.9 mm in two hours in our laboratory using these techniques. It was the goal of this work to extend this ESG approach to the growth of indium nitride. The hope was that the abundance of the activated form of nitrogen, namely the triply-charged nitride ion (N{sup -3}) would enable the facile growth of InN in solution at low temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Scientific/Technical Report of Gas Hydrate Dynamics on the Alaskan Beaufort Continental Slope: Modeling and Field Characterization

Methane Hydrates, a solid form of methane and water, exist at high pressures and low temperatures, occurs on every continental margin on Earth, represents one of the largest reservoirs of carbon on the planet, and, if destabilized, may play an important role in both slope stability and climate change. For decades, researchers have studied methane hydrates with the hope of determining if methane hydrates are destabilizing, and if so, how this destabilization might impact slope stability and ocean/atmosphere carbon budgets. In the past ~5 years, it has become well established that the upper “feather-edge” of methane hydrate stability (intermediate water depths of ~200-500 meters below sea level) represents an important frontier for methane hydrates stability research, as this zone is most susceptible to destabilization due to minor fluctuations in ocean temperature in space and time. The Arctic Ocean—one of the fastest warming regions on Earth—is perhaps the best place to study possible changes to methane hydrate stability due to ocean warming. To address the stability of methane hydrates at intermediate ocean depths, Southern Methodist University in partnership with Oregon State University and The United State Geological Survey at Woods Hole began investigating methane hydrate stability in intermediate water depths below both the US Beaufort Sea and the Atlantic Margin, from 2012-2017. The work was funded by the Department of Energy’s (DOE) National Energy Technology Laboratory (NETL). The key goal of the SMU component of this study was to collect the first ever heat flow data in the Beaufort Sea and compare measured shallow (probe-based1) heat flow values with deeper (BSR-derived2) heat flow values, and from this, determine whether hydrates were in thermal equilibrium. In September 2016, SMU/OSU collected the first ever heat flow measurements in the US Beaufort Sea. Despite poor weather and rough seas, the cruise was a success, with 116 heat flow measurements acquired across the margin, spanning 4 transects separated by more than 400 km. Useable heat flow data exists for 97% (113) of probe heat flow measurements, revealing a clear picture of regional heat flow across the basin. During the past 8 months since the cruise, SMU researchers have processed the heat flow and thermal conductivity measurements and compared results to deeper heat flow estimates obtained from seismic data. The analysis reveals clear, consistent trends: All probe heat flow measurements in depths greater than 800 mbsl are consistent with BSR-derived values; heat flow measurements obtained in water depths between ~250-750 mbsl are systematically lower than those estimated from BSRs; and heat flow estimates in water depths shallower than ~250 mbsl are systematically warmer than deeper estimates. The consistency between shallow (probe) and deep (BSR) heat flow measurements at depths greater than ~750 m where ocean temperature changes are minimal supports the premise that the hydrates consist primarily of methane and represent a valuable tool for estimating heat flow. The anomalous cooling trend observed in the upper 250 m is consistent with expected seasonal effects observed in shallow ocean buoy measurements in the arctic, when cold, less dense melting sea ice cools the upper 200 m of the ocean during the summer as ice melting occurs. The discrepancy in heat flow at intermediate water depths is best explained via recent intermediate ocean temperature warming, where long-term (annual or longer) warming intermediate ocean bottom waters result in an anomalously low heat flow in shallow heat flow measurements. Using the characteristic 1D time-length scale for diffusion, we estimate that ocean temperature warming began no later than ~1200 years ago but arguably much more recently as results are limited by seismic resolution. More importantly, our analysis indicates methane hydrate is destabilizing not only in the upper feather edge (200-500 mbsl) but at depths as great as 750 mbsl. The intermediate ocean warming rate supports previous studies suggesting geologically rapid warming (>0.1 deg C/decade) at intermediate ocean depths in the Beaufort Sea. Assuming no further changes or additional warming, our analysis indicates methane hydrates will destabilize at seafloor depths shallower than 750 mbsl in the Beaufort Sea within the next ~3000 years. 1 Probe outfitted with sensors inserted into the seafloor sediment 2 Bottom-simulating reflector (BSR) seismic data indicates presence of hydrate deposits

58 GEOSCIENCES↗

The iterative thermal emission method: A more implicit modification of IMC

For over 40 years, the Implicit Monte Carlo (IMC) method has been used to solve challenging problems in thermal radiative transfer. These problems typically contain regions that are optically thick and diffusive, as a consequence of the high degree of “pseudo-scattering” introduced to model the absorption and reemission of photons from a tightly-coupled, radiating material. IMC has several well-known features that could be improved: a) it can be prohibitively computationally expensive, b) it introduces statistical noise into the material and radiation temperatures, which may be problematic in multiphysics simulations, and c) under certain conditions, solutions can be nonphysical, in that they violate a maximum principle, where IMC-calculated temperatures can be greater than the maximum temperature used to drive the problem. We have developed a variant of IMC called iterative thermal emission IMC, which is designed to have a reduced parameter space in which the maximum principle is violated. ITE IMC is a more implicit version of IMC in that it uses the information obtained from a series of IMC photon histories to improve the estimate for the end of time step material temperature during a time step. A better estimate of the end of time step material temperature allows for a more implicit estimate of other temperature-dependent quantities: opacity, heat capacity, Fleck factor (probability that a photon absorbed during a time step is not reemitted) and the Planckian emission source. We have verified the ITE IMC method against 0-D and 1-D analytic solutions and problems from the literature. These results are compared with traditional IMC. We perform an infinite medium stability analysis of ITE IMC and show that it is slightly more numerically stable than traditional IMC. We find that significantly larger time steps can be used with ITE IMC without violating the maximum principle, especially in problems with non-linear material properties. The ITE IMC method does however yield solutions with larger variance because each sub-step uses a different Fleck factor (even at equilibrium)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An extreme metallicity, large-scale outflow from a star-forming galaxy at z ∼ 0.4

We present a detailed analysis of a large-scale galactic outflow in the circumgalactic medium of a massive (M{sub h}∼10{sup 12.5} M{sub ⊙}), star-forming (∼6.9 M{sub ⊙} yr{sup −1}), sub-L{sub *} (∼0.5L{sub B}{sup ∗}) galaxy at z = 0.39853 that exhibits a wealth of metal-line absorption in the spectra of the background quasar Q 0122−003 at an impact parameter of 163 kpc. The galaxy inclination angle (i=63{sup ∘}) and the azimuthal angle (Φ=73{sup ∘}) imply that the QSO sightline is passing through the projected minor-axis of the galaxy. The absorption system shows a multiphase, multicomponent structure with ultra-strong, wide velocity spread O VI (logN=15.16±0.04, Δv{sub 90} = 419 km s{sup −1}) and N V (logN=14.69±0.07, Δv{sub 90} = 285 km s{sup −1}) lines that are extremely rare in the literature. The highly ionized absorption components are well explained as arising in a low density (∼10{sup −4.2} cm{sup −3}), diffuse (∼10 kpc), cool (∼10{sup 4} K) photoionized gas with a super-solar metallicity ([X/H]≳0.3). From the observed narrowness of the Lyβ profile, the non-detection of S IV absorption, and the presence of strong C IV absorption in the low-resolution FOS spectrum, we rule out equilibrium/non-equilibrium collisional ionization models. The low-ionization photoionized gas with a density of ∼10{sup −2.5} cm{sup −3} and a metallicity of [X/H]≳−1.4 is possibly tracing recycled halo gas. We estimate an outflow mass of ∼2×10{sup 10} M{sub ⊙}, a mass-flow rate of ∼54 M{sub ⊙} yr{sup −1}, a kinetic luminosity of ∼9×10{sup 41} erg s{sup −1}, and a mass loading factor of ∼8 for the outflowing high-ionization gas. These are consistent with the properties of “down-the-barrel” outflows from infrared-luminous starbursts as studied by Rupke et al. Such powerful, large-scale, metal-rich outflows are the primary means of sufficient mechanical and chemical feedback as invoked in theoretical models of galaxy formation and evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Concentration Field of Reactants and Products Species in a Reacting Vortex Ring

The proposed paper will present experimental and numerical results on the concentration fields of both reactants and products species in a reacting vortex ring that is generated from the interaction between a diffusion flame and a laminar vortex ring. Flame-vortex interactions are canonical configurations used to study the underlying processes occurring in complicated turbulent reacting flows. This type of configuration contains many of the fundamental aspects of the coupling between fluid dynamics and combustion that could be investigated with more controllable conditions than are possible under direct investigations of turbulent flames. The current configuration has been studied experimentally by Chen and Dahm and Chen et al. under microgravity conditions, and by Park and Shin, and You et al. under normal gravity conditions. This configuration is similar to that used in the analyses of Karagozian and Manda of their 2-D vortex pair in which both fuel and entrained oxidizer are present. The vortex ring used in this study is generated by issuing methane into an air environment through the exit of an axisymmetric nozzle. The experiments were conducted under microgravity conditions in order to remove the undesirable effects of buoyancy that can affect both the flame structure and ring dynamics resulting in possibly asymmetric and nonrepeatable interactions. The experimental technique of diode laser wavelength modulation spectroscopy (WMS) is used to measure concentration fields of reactants, CH4 and O2, products, H2O, CO2, OH, and temperature fields which can be inferred from either line pairs of O2 or OH lines. This technique has been investigated previously by Silver and Bomse et al. This is the first time that the technique has been applied to reacting vortex rings under microgravity conditions. The effect of ring circulation and fuel volume on the species concentration fields will be investigated. The experimental results will be compared to the current numerical results, and used to validate the numerical studies. In addition, the existence of burned cores during the interactions will be determined, and the increase in reactant consumption with increased ring circulation will be examined. Numerical studies were also conducted by solving the Navier-Stokes and mixture fraction equations with the assumptions of unity Lewis and Schmidt numbers. Equilibrium chemistry and flamelet libraries were used to obtain the temperature and species mass fraction fields. The numerical results will serve as guidelines in conducting the experimental studies. Ring circulation and fuel volume effects on the interactions and species concentration fields will be investigated and compared to experimental results.

Chen, Shin-Juh↗

Fundamental Corrosion Studies in High-Temperature Molten Salt Systems for Next Generation Concentrated Solar Power Systems

The objective of this project is to increase Concentrated Solar Power (CSP) system lifetime through characterization of corrosion mechanisms in heat transfer systems and identification of materials and corrosion resistance methods applicable at temperatures above 850°C. Coupling of experimental methods with thermodynamic and kinetic modeling has given greater insight into the corrosion phenomena and enabled modeling of the corrosion in molten chloride heat transfer systems. The project has been identified the selective oxidation of Cr along the grain boundaries of high Cr content alloys as the principle corrosion mechanisms occurring in CSP systems. The corrosion rate was also found to be mass transfer limited by diffusion of chromium chlorides along the grain boundaries. It was shown that the corrosion could be increased by adding naturally convective flow to mechanism using a thermosiphon. A reaction mechanism has been proposed for selective oxidation of Cr that is driven by the electrochemical potential difference between the Ni crucible for immersion testing and the alloy coupon. This driving force will be similar to the differences caused by having varying Ni content or Cr content throughout a heat transfer system. It could also mimic the differences in electrochemical potential between various parts of the system that are at different temperatures. The reaction mechanism consists of an initiation step due to system impurities and a set of propagation steps that results in formation of a NiCr alloy at the crucible that drives corrosion and selective oxidation of Cr from the alloy. The presences of chromium chlorides in the salt are also essential to the corrosion mechanism to transport the Cr. The formation of a NiCr alloy on the crucible surface with no contact between the alloy coupons and the crucible provides support to this mechanism of having corrosion reactions occurring at both the alloy and the crucible. The thermodynamics of this reaction mechanism have been modeled and were shown to be galvanic. A corrosion model has been developed based on this mechanism and has been implemented in CFD so that it can be used to predict corrosion in a wide variety of system geometries. The model was validated using the thermosiphon data and dimensionless analysis. The corrosion rates of the samples were modeled to within 10% percent of the experimental values. The model has been extended to include the effect of Mg corrosion inhibitor on the corrosion rate in the system. The use of Mg as a metallic corrosion inhibitor has been demonstrated as a method to reduce the corrosion rate of alloys in molten chlorides to below 15 microns per year. Mg is an effective corrosion inhibitor at concentrations as low as 0.3 mol%. Corrosion potential monitoring experiments have shown that the Mg lowers the corrosion potential for the alloy below the equilibrium potential for Cr oxidation and thus prevents corrosion. Experiments have been performed on the ability of Mg to inhibit corrosion in realistic environments that include lower purity salts and welded and stressed alloys. The results have shown that for all these scenarios the corrosion can be reduced to meet the DOE targets. The electrochemical monitoring of Mg for process control has also been demonstrated.

14 SOLAR ENERGY↗

Fourier Analysis of the Multilevel QD Method with {alpha}-Approximation For Time-Dependent Radiative Transfer Problems

Thermal radiation transfer (TRT) problems describe interaction of photon radiation with matter. They are defined by the time-dependent radiative transfer (RT) equation for the specific intensity I coupled with the energy balance (EB) equation. This class of problems is characterised by high dimensionality, multiple scales and strong nonlinearity. In this paper we analyze the multilevel quasi-diffusion (QD) method for solving TRT problems. This is a nonlinear method of moments with exact closures. The QD method enables one to reduce dimensionality of the original radiative transfer problem. It is formulated by a nonlinear system of equations consisting of (i) the high-order RT (HORT) equation for the intensity of photon radiation and (ii) low-order equations for the angular and energy moments of the intensity. The nonlinear closures are formulated by means of stable factors. The low-order problem brings the radiative transfer model to the level of multi-physics equations. The multilevel QD (MLQD) method possesses attractive features for efficient multi-physics coupling. To calculate the high-order RT solution we apply the {alpha}-approximation which assumes that the intensity changes exponentially in time over a time step. The {alpha}-approximation leads to the steady-state RT equation with a modified opacity and enables one to avoid storing the high-dimensional solution from the previous time step. The rate of change is evaluated by the solution of the time-dependent low-order QD (LOQD) equations for moments. We note that the HORT equation in the {alpha}-approximation contains an extra nonlinear term. It affects the iterative behaviour of the MLQD method. The obtained computational results indicated that the rate of convergence is slower compared to the rate when the time-dependent HORT is used to calculate the intensity. In this paper we perform an iterative stability analysis of the MLQD method in a discretized form and analyze convergence of outer (transport) iterations on a time step. We consider multigroup TRT problems in 1D slab geometry. The fully implicit scheme is used to discretize equations in time. The HORT equation is approximated with the method of step characteristics. A finite volume method is applied for spatial discretization of multigroup LOQD equations. The grey (one-group) LOQD equations are algebraically consistent with the multigroup LOQD equations. To perform Fourier analysis a model TRT problem in an infinite homogeneous medium is considered. The system of nonlinear equations of the MLQD method is linearized near an equilibrium solution at some given temperature. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Partnership for Edge Physics Simulation

A major goal of our participation in the Edge Physics Simulation project has been to contribute to the understanding of the self-organization of tokamak turbulence fluctuations resulting in the formation of a staircase structure in the ion temperature. A second important goal is to demonstrate how small scale turbulence in plasmas self-organizes with dynamically driven quasi-stationary flow shear. These goals have been accomplished through the analyses of the statistical properties of XGC1 flux driven Gyrokinetic electrostatic ion temperature gradient (ITG) turbulence simulation data in which neutrals are included. The ITG turbulence data, and in particular fluctuation data, were obtained from a massively parallel flux-driven gyrokinetic full-f particle-in-cell simulation of a DIII-D like equilibrium. Below some the findings are summarized. It was observed that the emergence of staircase structure is related to the variations in the normalized temperature gradient length (R/LT) and the poloidal flow shear. Average turbulence intensity is found to be large in the vicinity of minima in R/LTi, where ITG growth is expected to be lower. The distributions of the occurrences of potential fluctuation are found to be Gaussian away from the staircase-step locations, but they are found to be non-Gaussian in the vicinity of staircase-step locations. The results of analytically derived expressions for the distribution of the occurrences of turbulence intensity and intensity flux were compared with the corresponding quantities computed using XGC1 simulation data and good agreement is found. The derived expressions predicts inward and outward propagation of turbulence intensity flux in an intermittent fashion. The outward propagation of turbulence intensity flux occurs at staircase-step locations and is related to the change in poloidal flow velocity shear and to the change in the ion temperature gradient. The standard deviation, skewness and kurtosis for turbulence quantities were computed and found to be large in the vicinity of the staircase-step structures. Large values of skewness and kurtosis can be explained by a temporary opening and closing of the structure which allows turbulence intensity events to propagate. The staircase patterns may reduce the ion heat transport and a manipulation of these patterns may be used to optimize heat transport in tokamaks. An additional objective of the research in support of the Edge Physics Simulation initiative has been to improve the understanding of scrape-off layer thermal transport. In planning experiments and designing future tokamaks, it is important to understand the physical effects that contribute to divertor heat-load fluxes. The research accomplished will contribute to developing new models for the scrape-off layer region. The XGC0 code was used to compute the heat fluxes and the heat-load width in the outer divertor plates of C-Mod and DIII-D tokamaks. It was observed that the width of the XGC0 neoclassical heat-load was approximately inversely proportional to the total plasma current. Anomalous transport in the H-mode pedestal region of five Alcator C-Mod discharges, representing a collisionality scan, was analyzed. The understanding of anomalous transport in the pedestal region is important for the development of a comprehensive model for the H-mode pedestal slope. It was found that the electron thermal anomalous diffusivities at the pedestal top increase with the electron collisionality. This dependence can point to the DRIBM as the modes that drive the anomalous transport in the plasma edge of highly collisional discharges. The effects of plasma shaping on the H-mode pedestal structure was also investigated. The differences in the predicted H-mode pedestal width and height for the DIII-D discharges with different elongation and triangularities were discussed. For the discharges with higher elongation, it was found that the gradients of the plasma profiles in the H-mode pedestal reach semi-steady states. In these simulations, the pedestal slowly continued to evolve to higher pedestal pressures and bootstrap currents until the peeling ballooning stability conditions were satisfied. The discharges with lower elongation do not reach the semi-steady state, and ELM crashes were triggered at earlier times. The plasma elongation was found to have a stronger stabilizing effect than the plasma triangularity. For the discharges with lower elongation and lower triangularity, the ELM frequency was large, and the H-mode pedestal evolves rapidly. It was found that the temperature of neutrals in the scrape-off-layer region can affect the dynamics of the H-mode pedestal buildup. However, the final pedestal profiles were nearly independent of the neutral temperature. The elongation and triangularity affected the pedestal widths of plasma density and electron temperature profiles differently. This study illustrated a new mechanism for controlling the pedestal bootstrap current and the pedestal stability.

97 MATHEMATICS AND COMPUTING↗

Modeling Mesoscale Processes of Scalable Synthesis (Final Report)

The main objective of the center is to develop tools that can help for the understanding of equilibrium and non-equilibrium properties of nanoparticles in aqueous electrolytes. To achieve this goal, we need to develop new computational methodologies that can integrate molecular level description such as the electronic structure analysis to mesoscale description such as generalized hydrodynamics. The challenge is to develop systematic coarse graining techniques that can adaptively choose the level of description needed for the particular task. For example, if bonding breaking is involved, then one should use appropriate models from quantum mechanics to accurately model the time scale and molecular mechanism for the breaking process. However, to model transport process or the process of self-assembly, much less detailed models can be used. There are two main components to this task. One is to develop accurate models that bridge different levels of description. The classical example is the QM/MM model that bridges quantum mechanics and molecular mechanics for studying chemical reactions of large molecules. This work was awarded the Nobel prize this year. For our purpose, we also need to develop methods that bridge molecular and continuum levels of description. Another main task is to develop systematic coarse-graining methods that can give rise to accurate mesoscale and macroscale models, starting from more detailed models at the atomic or molecular scale. None of these ideas are new. By now they have been fashionable topics for quite some time. But neither problem is satisfactorily resolved. The main problem is that uncontrolled approximations are used. As a result, we have very little idea about the validity and accuracy of these models. The main purpose of the center is to exploit the Mori-Zwanzig formalism to achieve the goals stated above. The Mori-Zwanzig formalism is a general tool for eliminating degrees of freedom from existing models. What is attractive about this formalism is its generality. The flip side is that it is also somewhat of a tautology. In order to make it a practical tool, one has to make approximations and this is where the trouble comes. Instead of focusing on Mori-Zwanzig formalism, the PI proposes to study the closely related renormalization group formalism (RG). Like Mori-Zwanzig, RG is a general strategy for eliminating small scale degrees of freedom in a model. Unlike Mori-Zwanzig, RG has the advantage that at least for some problems, one can write a PDE (partial differential equation) type of model for the exact RG flow, without any approximation. This gives us a solid starting point for discussing and analyzing approximations. The PI studied approximate RG flows for turbulent diffusion and related problems. However, extending it to more practical problems proved to be hard. The second line that the PI has pursued is to develop special numerical algorithms for studying particularly important events for dynamics processes in meso-scale systems. The PI succeeded in doing so for the problem of understanding phase transition in metallic systems.

97 MATHEMATICS AND COMPUTING↗

TU-EF-BRA-00: MR Basics I

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI (f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-01: NMR and Proton Density MRI of the 1D Patient

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-02: Longitudinal Proton Spin Relaxation and T1-Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-03: Free Induction Decay (without the Decay) and Spin-Echo Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-04: Into 2, 3, and 4 Dimensions

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

Elliptic flow of heavy-flavor decay electrons in Au+Au collisions at s NN = 27 and 54.4 GeV at RHIC

We report on new measurements of elliptic flow (v 2 ) of electrons from heavy-flavor hadron decays at mid-rapidity (|y| < 0.8) in Au+Au collisions at $\sqrt{s{NN}}$ = 27 and 54.4 GeV from the STAR experiment. Heavy-flavor decay electrons (eHF) in Au+Au collisions at $\sqrt{s{NN}}$ = 54.4 GeV exhibit a non-zero v 2 in the transverse momentum (p T ) region of p T < 2 GeV/c with the magnitude comparable to that at $\sqrt{s{NN}}$=200 GeV. The measured e HF v 2 at 54.4 GeV is also consistent with the expectation of their parent charm hadron v 2 following number-of-constituent-quark scaling as other light and strange flavor hadrons at this energy. These suggest that charm quarks gain significant collectivity through the evolution of the QCD medium and may reach local thermal equilibrium in Au+Au collisions at $\sqrt{s{NN}}$=54.4 GeV. The measured e HF v 2 in Au+Au collisions at $\sqrt{s{NN}}$ = 27 GeV is consistent with zero within large uncertainties. The energy dependence of v 2 for different flavor particles (π,Φ,D 0 /e HF ) shows an indication of quark mass hierarchy in reaching thermalization in high-energy nuclear collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗