Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

A Space-Filling Visualization Technique for Multivariate Small World Graphs

We introduce an information visualization technique, known as GreenCurve, for large sparse graphs that exhibit small world properties. Our fractal-based design approach uses spatial cues to approximate the node connections and thus eliminates the links between the nodes in the visualization. The paper describes a sophisticated algorithm to order the neighboring nodes of a large sparse graph by solving the Fiedler vector of its graph Laplacian, and then fold the graph nodes into a space-filling fractal curve based on the Fiedler vector. The result is a highly compact visualization that gives a succinct overview of the graph with guaranteed visibility of every graph node. We show in the paper that the GreenCurve technology is (1) theoretically sustainable by introducing an error estimation metric to measure the fidelity of the new graph representation, (2) empirically rigorous by conducting a usability study to investigate its strengths and weaknesses against the traditional graph layout, and (3) pragmatically feasible by applying it to analyze stressed conditions of the large scale electric power grid on the west coast.

99 GENERAL AND MISCELLANEOUS↗

Third-party transfers in WLCG using HTTP

Since its earliest days, the Worldwide LHC Computational Grid (WLCG) has relied on GridFTP to transfer data between sites. The announcement that Globus is dropping support of its open source Globus Toolkit (GT), which forms the basis for several FTP client and servers, has created an opportunity to reevaluate the use of FTP. HTTP-TPC, an extension to HTTP compatible with WebDAV, has arisen as a strong contender for an alternative approach.In this paper, we describe the HTTP-TPC protocol itself, along with the current status of its support in different implementations, and the interoperability testing done within the WLCG DOMA working group’s TPC activity. This protocol also provides the first real use-case for token-based authorisation for this community. We will demonstrate the benefits of such authorisation by showing how it allows HTTP-TPC to support new technologies (such as OAuth, OpenID Connect, Macaroons and SciTokens) without changing the protocol. We will also discuss the next steps for HTTP-TPC and the plans to use the protocol for WLCG transfers.

Bockelman, Brian↗

Hybrid strategies and technologies for full spectrum solar conversion

Harvesting the full spectrum of sunlight using a hybrid approach offers the potential for higher efficiencies, lower power production costs, and increased power grid compatibility than any single technology by itself. In this article, the base technologies for converting sunlight into electricity, including photovoltaics and solar thermal approaches are discussed. Then feasible strategies for combining them to utilize the various portions of the solar spectrum most effectively are discussed. In this study, we particularly focus on the advantages of a spectral splitting approach. This helps to convert higher energy photons (UV and visible) directly into electrons using optimized single or tandem photovoltaic (PV) cells, while capturing lower energy photons as heat using a selective solar absorber, which absorbs photons within a range of energies, down to a cutoff in the mid-infrared. The solar heat is then thermally concentrated and driven through a high temperature thermoelectric generator on top of a high efficiency mechanical engine (e.g., a steam-driven Rankine cycle) through a heat exchanger, which connects to both thermal storage and the mechanical engine at 550 °C. The thermal storage allows for significant flexibility in the time of power generation (also known as dispatchability) at a modest cost. Furthermore, the system can produce power for hours after sunset. Ideally, the system can achieve efficiencies over 50% using a combination of an InAlAs/InGaP tandem photovoltaics, ErAs:(InGaAs) 1– x (InAlAs) x thermoelectrics, and mechanical Rankine cycles. The configuration and operating conditions can be optimized to minimize the levelized cost of energy (LCOE).

14 SOLAR ENERGY↗

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximization of Platoon Formation Through Centralized Routing and Departure Time Coordination

Platooning allows vehicles to travel with a small intervehicle distance in a coordinated fashion because of vehicle-to-vehicle connectivity. When applied at a larger scale, platooning creates significant opportunities for energy savings because of reduced aerodynamic drag, as well as increased road capacity and a reduction in congestion resulting from shorter vehicle headways. These potential savings are maximized, however, if platooning-capable vehicles spend most of their travel time within platoons. Ad hoc platoon formation may not ensure a high rate of platoon driving. This paper considers here the problem of central coordination of platooning-capable vehicles. Coordination of their routes and departure times can maximize the fuel savings afforded by platooning vehicles. The resulting problem is a combinatorial optimization problem that considers the platoon coordination and vehicle routing problems simultaneously. The methodology is demonstrated through evaluation of the benefits of a coordinated solution and comparison with the uncoordinated case when platoons form only in an ad hoc manner. The coordinated and uncoordinated scenarios are compared on a grid network with various assumptions about demand and the time vehicles are willing to wait.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detecting Peer-to-Peer Botnets in SCADA Systems

Supervisory Control and Data Acquisition (SCADA) systems monitor and control critical infrastructure such as the smart grid. As SCADA systems become increasingly interconnected and adopt more and more cyber-enabled components, the risks of cyber attacks become a major concern. Due to their decentralized organization, peer-to-peer (P2P) botnets are resilient to many existing takedown measures and can be exploited as an effective way to launch cyber attacks on SCADA systems. However, little work has been done to detect P2P botnets in SCADA systems, which carry traffic flows with characteristics significantly different from the Internet. In this paper, we design a P2P-botnet detection method for SCADA systems, leveraging built-in traffic monitoring capabilities of SCADA networking devices. The proposed method consists of two stages. In the first stage, we design a simple feature test to filter out non-P2P hosts, which significantly reduces the data volume for P2P-botnet identification. In the second stage, we jointly consider flow-based and connectivity-based features that effectively set apart bots from benign hosts. We propose to use unsupervised learning for P2P-botnet identification, which not only identifies known P2P botnets but also captures newly emerged ones. Our simulation results show that the proposed system achieves high detection rates with very few false positives. Furthermore, our evaluation shows that the proposed method can detect hosts running P2P SCADA applications that are infected by P2P bots.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Advanced Semi-Supervised Learning with Uncertainty Estimation for Phase Identification in Distribution Systems

The integration of advanced metering infrastructure (AMI) into power distribution networks generates valuable data for tasks such as phase identification; however, the limited and unreliable availability of labeled data in the form of customer phase connectivity presents challenges. To address this issue, we propose a semi-supervised learning (SSL) framework that effectively leverages labeled and unlabeled data. Our approach incorporates self-training, label spreading, and Bayesian neural networks (BNNs) to enhance phase identification with AMI data. Our method uses an ensemble of multilayer perceptron classifiers in a self-training setup, iteratively adding high-confidence pseudo-labels to improve robustness. We also apply label spread to propagate labels based on data similarity, which enhances generalization across diverse distributions. In addition, we employ a BNNs with uncertainty estimation, boosting confidence in predictions and reducing phase identification errors. In our case study, we achieved approximately 98% +/- 0.08 accuracy with uncertainty using minimal and unreliable labeled data from a real U.S. utility, Duquesne Light Company. Our SSL approach, combined with uncertainty estimation, provides an efficient solution for phase identification in AMI data, ultimately improving the reliability of smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Semi-Supervised Learning With Uncertainty Estimation for Phase Identification in Distribution Systems

The integration of advanced metering infrastructure (AMI) into power distribution networks generates valuable data for tasks such as phase identification; however, the limited and unreliable availability of labeled data in the form of customer phase connectivity presents challenges. To address this issue, we propose a semi-supervised learning (SSL) framework that effectively leverages labeled and unlabeled data. Our approach incorporates self-training, label spreading, and Bayesian neural networks (BNNs) to enhance phase identification with AMI data. Our method uses an ensemble of multilayer perceptron classifiers in a self-training setup, iteratively adding high-confidence pseudo-labels to improve robustness. We also apply label spread to propagate labels based on data similarity, which enhances generalization across diverse distributions. In addition, we employ a BNNs with uncertainty estimation, boosting confidence in predictions and reducing phase identification errors. In our case study, we achieved approximately 98% +/- 0.08 accuracy with uncertainty using minimal and unreliable labeled data from a real U.S. utility, Duquesne Light Company. Our SSL approach, combined with uncertainty estimation, provides an efficient solution for phase identification in AMI data, ultimately improving the reliability of smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How Would the Twenty-First-Century Warming Influence Pacific Decadal Variability and Its Connection to North American Rainfall: Assessment Based on a Revised Procedure for the IPO/PDO

Decadal climate variability of sea surface temperature (SST) over the Pacific Ocean can be characterized by interdecadal Pacific oscillation (IPO) or Pacific decadal oscillation (PDO) based on empirical orthogonal function (EOF) analysis. Although the procedures to derive the IPO and PDO indices differ in their regional focuses and filtering methods to remove interannual variability, the IPO and PDO are highly correlated in time and are often used interchangeably. Studies have shown that the IPO and PDO conjointly (IPO/PDO for conciseness) play a vital role in modulating the pace of global warming. It is less clear, however, how externally forced global warming may, in turn, affect the IPO/PDO. One obstacle to revealing this effect is that the conventional definitions of the IPO/PDO fail to account for the spatial heterogeneity of the background warming trend, which causes the IPO/PDO to be conflated with the warming trend, especially for the twenty-first-century simulation when the forced change is likely to be more dominant. Using a large-ensemble simulation in the Community Earth System Model, version 1 (CESM1), it is shown here that a better practice of detrending prior to EOF analysis is to remove the local and nonlinear trend, defined as the ensemble-mean time series at each grid box (or simply as the quadratic fit of the local time series if such an ensemble is not available). The revised IPO/PDO index is purely indicative of internal decadal variability. In the twenty-first-century warmer climate, the IPO/PDO has a weaker amplitude in space, a higher frequency in time, and a muted impact on global and North American temperature and rainfall.

54 ENVIRONMENTAL SCIENCES↗

Kimberlina 1.2 CCUS Geophysical Models and Synthetic Data Sets

This synthetic multi-scale and multi-physics data set was produced in collaboration with teams at the Lawrence Berkeley National Laboratory, National Energy Technology Laboratory, Los Alamos National Laboratory, and Colorado School of Mines through the Science-informed Machine Learning for Accelerating Real-Time Decisions in Subsurface Applications (SMART) Initiative. Data are associated with the following publication: Alumbaugh, D., Gasperikova, E., Crandall, D., Commer, M., Feng, S., Harbert, W., Li, Y., Lin, Y., and Samarasinghe, S., “The Kimberlina Synthetic Geophysical Model and Data Set for CO2 Monitoring Investigations”, The Geoscience Data Journal, 2023, DOI: 10.1002/gdj3.191. The dataset uses the Kimberlina 1.2 CO2 reservoir flow model simulations based on a hypothetical CO2 storage site in California (Birkholzer et al., 2011; Wainwright et al., 2013). Geophysical properties models (P- and S-wave seismic velocities, saturated density, and electrical resistivity) were produced with an approach similar to that of Yang et al. (2019) and Gasperikova et al. (2022) for 100 Kimberlina 1.2 reservoir models. Links to individual resources are provided below: [CO2 Saturation Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-co2-saturation-models); Resistivity Models – [part 1](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-resistivity-models-part-1), [part 2](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-resistivity-models-part-2), and [part 3](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-resistivity-models-part-3); [Vp Velocity Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-vp-velocity-models); [Vs Velocity Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-vs-velocity-models); [Density Models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-density-models). The 3D distributions of geophysical properties for the 33 time stamps of the SIM001 model were used to generate synthetic seismic, gravity, and electromagnetic (EM) responses for 33 times between zero and 200 years. Synthetic surface seismic data were generated using 2D and 3D finite-difference codes that simulate the acoustic wave equation (Moczo et al., 2007). 2D data were simulated for six point-pressure sources along a 2D line with 10 m receiver spacing and a time spacing of 0.0005 s. 3D simulations were completed for 25 surface pressure sources using a source separation of 1 km in both the x and y directions and a time spacing of 0.001 s. Links to individual resources are provided below: [2D velocity models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-2d-velocity-models) and [2D surface seismic data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-2d-surface-seismic-data). [3D velocity models](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-velocity-models), and 3D seismic data [year0](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year0), [year1](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year1), [year2](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year2), [year5](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year5), [year10](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year10), [year15](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year15), [year20](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year20), [year25](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year25), [year30](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year30), [year35](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year35), [year40](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year40), [year45](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year45), [year49](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year49), [year50](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year50), [year51](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year51), [year52](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year52), [year55](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year55), [year60](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year60), [year65](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year65), [year70](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year70), [year75](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year75), [year80](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year80), [year85](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year85), [year90](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year90), [year95](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year95), [year100](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year100), [year110](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year110), [year120](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year120), [year130](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year130), [year140](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year140), [year150](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year150), [year175](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year175), [year200](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-seismic-data-year200). The Python scripts to read these models and data are provided [here](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-python-scripts). EM simulations used a borehole-to-surface survey configuration, with the source located near the reservoir level and receivers on the surface using the code developed by Commer and Newman (2008). Pseudo-2D data for the source at [2500 m](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-pseudo-2d-csem-data-tz2500m) and [3025 m](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-pseudo-2d-csem-data-tz3025m), used a 2D inline receiver configuration to simulate a response over 3D resistivity models. The [3D data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-3d-csem-data) contain electric fields generated by borehole sources at monitoring well locations and measured over a surface receiver grid. Vector gravity data, both on the surface and in boreholes, were simulated using a modeling code developed by Rim and Li (2015). The simulation scenarios were parallel to those used for the EM: [pseudo-2D data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-gravity-data) were calculated along the same lines and within the same boreholes, and [3D data](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-gravity-data) were simulated over 3D models on the surface and in three monitoring wells. A series of [synthetic well logs](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-well-logs) of CO2 saturation, acoustic velocity, density, and induction resistivity in the injection well and three monitoring wells are also provided at 0, 1, 2, 5, 10, 15, and 20 years after the initiation of injection. These were constructed by combining the low-frequency trend of the geophysical models with the high-frequency variations of actual well logs collected in the Kimberlina 1 well that was drilled at the proposed site. Measurements of permeability and pore connectivity were made on cores of Vedder Sandstone, which forms the primary reservoir unit: [CT micro scans](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-ct-micro-scans-of-vedder-formation) and [Industrial CT Images](https://edx.netl.doe.gov/dataset/kimberlina-1-2-ccus-geophysical-models-and-synthetic-data-sets-industrial-ct-images-vedder-formation). These measurements provide the range of scales in the otherwise synthetic data set to be as close to a real-world situation as possible. References: Birkholzer, J.T., Zhou, Q., Cortis, A. and Finsterle, S., 2011. A sensitivity study on regional pressure buildup from large-scale CO2 storage projects. Energy Procedia, 4, 4371-4378. Commer, M., and Newman, G.A., 2008. New advances in three-dimensional controlled-source electromagnetic inversion, Geophysical Journal International, 172, 513-535. Gasperikova, E., Appriou, D., Bonneville, A., Feng, Z., Huang, L., Gao, K., Yang, X., Daley, T., 2022, Sensitivity of geophysical techniques for monitoring secondary CO2 storage plumes, Int. J. Greenh. Gas Control, Volume 114, 103585, ISSN 1750-5836, https://doi.org/10.1016/j.ijggc.2022.103585. Moczo, P., J.O. Robertsson and L. Eisner, 2007, The finite-difference time-domain method for modeling of seismic wave propagation: Advances in geophysics, 48, 421-516. Rim, H., and Y. Li, 2015, Advantages of borehole vector gravity in density imaging, Geophysics, 80, G1-G13. Wainwright, H. M.; Finsterle, S.; Zhou, Q.; Birkholzer, J. T., 2013. Modeling the Performance of Large-Scale CO2 Storage Systems: A Comparison of Different Sensitivity Analysis Methods. International Journal of Greenhouse Gas Control, 17, 189205. https://doi.org/10.1016/j.ijggc.2013.05.007, DOI: 10.18141/1603331. Yang, X., Buscheck, T.A., Mansoor, K., Wang, Z., Gao, K., Huang, L., Appriou, D., and Carroll, S.A., 2019. Assessment of geophysical monitoring methods for detection of brine and CO2 leakage in drinking water aquifers, International Journal of Greenhouse Gas Control, 90, 102803, https://doi.org/10.1016/j.ijggc.2019.102803.

CCUS↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

aggregates↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events: Preprint

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

IEEE 1547 2018↗

FY 2016 Status Report: Documentation of All CIRFT Data including Hydride Reorientation Tests (Draft M2)

The first portion of this report provides a detailed description of fiscal year (FY) 2015 test result corrections and analysis updates based on FY 2016 updates to the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) program methodology, which is used to evaluate the vibration integrity of spent nuclear fuel (SNF) under normal conditions of transport (NCT). The CIRFT consists of a U-frame test setup and a real-time curvature measurement method. The three-component U-frame setup of the CIRFT has two rigid arms and linkages connecting to a universal testing machine. The curvature SNF rod bending is obtained through a three-point deflection measurement method. Three linear variable differential transformers (LVDTs) are clamped to the side connecting plates of the U-frame and used to capture deformation of the rod. The second portion of this report provides the latest CIRFT data, including data for the hydride reorientation test. The variations in fatigue life are provided in terms of moment, equivalent stress, curvature, and equivalent strain for the tested SNFs. The equivalent stress plot collapsed the data points from all of the SNF samples into a single zone. A detailed examination revealed that, at the same stress level, fatigue lives display a descending order as follows: H. B. Robinson Nuclear Power Station (HBR), LMK, and mixed uranium-plutonium oxide (MOX). Just looking at the strain, LMK fuel has a slightly longer fatigue life than HBR fuel, but the difference is subtle. The third portion of this report provides finite element analysis (FEA) dynamic deformation simulation of SNF assemblies . In a horizontal layout under NCT, the fuel assembly’s skeleton, which is formed by guide tubes and spacer grids, is the primary load bearing apparatus carrying and transferring vibration loads within an SNF assembly. These vibration loads include interaction forces between the SNF assembly and the canister basket walls. Therefore, the integrity of the guide tubes and spacer grids critically affects the vibration intensity of the fuel assembly during transport and must be considered when developing the multipurpose purpose canister (MPC) design for safe SNF transport.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving Primary Frequency Response to Support Networked Microgrid Operations

Individual microgrids have proven their ability to provide uninterrupted power to critical end-use load during severe events. Building on the performance of individual microgrids during extreme events, there has been an increasing interest in the operations of network microgrids. By networking microgrids during extreme events, it is possible to share resources, increase the duration for which they can operate islanded, and increase the resiliency of critical end-use loads. While there are benefits to networking the operations of resiliency-based microgrids, the switching operations that they require introduce transients which can result in a loss of dynamic stability. The issue of dynamic stability is especially acute in microgrids with high penetrations of inverter-connected generation, and a correspondingly low system inertia. While the low-inertia of these microgrids can be increased by over-sizing the rotating generators, the increased capital and operating costs can become a barrier to deployment. This work will present a method of augmenting primary frequency controls to support the switching transients necessary for the operation of networked microgrids, without the need to over-size rotating machines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Primary System Test Facility Review

Idaho National Laboratory (INL) is designing a Dynamic Energy Transport and Integration Laboratory (DETAIL) to demonstrate the operation of an integrated energy system as part of supporting research and development needs for the DOE Office of Nuclear Energy Integrated Energy Systems (IES) Program. DETAIL will demonstrate real-time integration with the electrical grid, renewable energy inputs, thermal and electrical energy storage, and energy delivery to an end user. A Thermal Energy Distribution System (TEDS) is being constructed within the DETAIL facility to demonstrate the operation of integrated energy system heat transfer components, thermal energy storage, distribution systems, and instrumentation and control (I&C), which will allow the facility to emulate the distribution of thermal energy to the generation of electrical power, and/or producing non-electrical commodities (e.g., hydrogen). As is the case for other subsystems within DETAIL, TEDS is designed to operate either independently or as a part of an integrated system to demonstrate the operation of integrated components, develop and validate thermal energy transport models and control systems, and study thermal energy inertia and energy storage. In an effort to completely understand how TEDS will integrate with operational plants, data from tests previously run at existing integral system test facilities (IST) will be used to drive the TEDS heater. Alternatively, a real-time data connection would allow steam conditions at the IST to drive the TEDS heater at the same time as having TEDS conditions provide feedback to the IST in terms of steam demand and/or pressure. This integrated testing approach will assess the ability of TEDS to operate during all plant conditions. Three existing integral system test facilities have been reviewed to determine their suitability for demonstrating TEDS capabilities when integrated within the DETAIL. This report summarizes the capabilities of each IST facility and any challenges that must be overcome to meet the operational needs of TEDS and DETAIL.

25 ENERGY STORAGE↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Enhanced Inertial Support: Modeling Fast Frequency Response Controls for Energy Storage System Inverters

Reduction of power system inertia is a growing concern for grid operators given the transition under way from conventional fossil generators to inverter-based resources. One key concern is the rapid and severe dip in power system frequency following a large disturbance which could trigger remedial actions including operation of under frequency load shedding (UFLS) relays. A potential solution is to utilize battery energy storage systems (BESS) to provide fast frequency response(FFR) to mitigate the system frequency impact of low system inertia. In this work, we investigate different control parameters to achieve modeled FFR response from BESS in the simulated US Western Interconnection. First, a very low inertia model is developed from an existing positive sequence model of the Western Interconnection. Afterwards, we tune the BESS dynamic response parameters to eliminate any risks of reaching UFLS relay thresholds following the loss of large generators. Finally, we investigate the relative impact of having large BESS units in comparison of multiple smaller units in the same area. The results of the analyses indicate that 1 GW of transmission-connected BESS can help mitigate the frequency drop caused by large generators outages in the Western Interconnection, and significantly reduce the risk of under frequency load shedding.

power system dynamic performance, Low Inertia, Fas↗

Data Analytics for Electrical Distribution Systems with Micro PMUs (GMLC 1.4.9 Technical Report)

This report describes how electrical utilities with residential, industrial, commercial and government customers make decisions using Data Analytics (DA) applications and discusses how OpenFMB was leveraged to share that data among disparate types of devices for DA. OpenFMB is a data standard developed by utilities for distributed communication and control of power system assets. Here we explored how OpenFMB can be used for sharing analytics and what those analytics could be for a set of representative grid devices. A review of DA applications performed by electrical utilities and customers is presented. An overview of how the testbed we used was built and configured is summarized. Several experiments which were carried out to explore the capabilities of OpenFMB alongside other data sharing mechanisms for gathering sensor measurements and sharing analytics is also discussed. And finally a comparison of OpenFMB and LBNL’s SPARK framework is summarized. Today’s electrical utilities focus on monitoring the real-time customer consumptions, offering new real-time tariff models based on customer usage habits (rewards and punishments), providing energy peak during peak load times (plan energy generation and distribution), improving the load management for transformers and power lines, and controlling the energy and grid resources efficiently. On the other hand, the DA applications for residential customers are based on modifying the customer electricity usage habit to save money, making accurate and timely decisions for electrical billing. However, the DA applications for industrial, commercial and government customers focus on creating efficient programs to improve the environmental condition (reducing CO₂ emission), developing better load forecasting for industrial and/or commercial activities. In this project, a testbed was built to explore how the OpenFMB framework can be used to distribute data among various types of representative grid edge devices. Micro PMUs (Phasor Measurement Unit) were used to collect and transmit data to an OpenPDC server alongside relays with a framework configured with a system using OpenFMB to collect and transmit data. The testbed was composed of a physical asset based on a 60 Hz AC radial power system constructed using SI-GRID components. The power system consisted of a 3-phase 14 volts line-to-ground (24 volts line-to-line) power source, three 3-phase line emulators, a programmable resistive load bank, two smart relays, two micro PMUs, and a (SCADA) and Phasor Data Concentrator (PDC) computer. This testbed configuration allowed us to perform breaker operation tests collecting data from the micro PMUs and from the relays’ sensors. During the micro PMU breaker operation tests we collected the measured and estimated fundamental voltages, currents, frequency as well as the total true, reactive and apparent power. The displacement power factor from two micro PMUs located in parallel power lines was also used. The software steps for the implementation of the Synchrophasor system are explained in detail in this report. The setting (1-2-3) and data collection (4-5) phases were performed with a free download open source software. In the setting phase, the micro PMUs were set (1), the data stream for each micro PMU was validated, and the connection and configuration files were created (2). The PDC computer was set using the connection and configuration files of the micro PMUs (3). In the data collection phase, the binary data from the micro PMUs was collected (4), and the binary data files of the micro PMUs was converted to analyze the test results (5). OpenFMB was configured to use protocol translators to read Modbus and transform the reading into the OpenFMB data model to be read for DA applications.Our experiments showed that by leveraging the OpenFMB data model and the micro PMUs together we could obtain better situational awareness of network faults, which in some cases could lead to failures in the system and would be less perceivable otherwise. For example, in one experiment the fundamental RMS current angle, and the fundamental displacement power factor (estimated by the ratio between the measured real and apparent total power) had a disturbance at the micro PMU connected to the beginning of the parallel power line because the breaker was opened without the operators or SCADA system’s knowledge, and no current was available. Based on the breaker state scenarios and micro PMU locations, the DA applications using the current angle and displacement power factor from the micro PMUs should be studied in detail to avoid a non-desired measurement that could affect the decision from the DA. Also, the sample rates for PMU, Relay and micro PMU devices were compared. The DA application improved the control and operation between the electrical utilities and their customers (residential, industrial, transportation, commercial and government). The higher the sample rate, the better the quality of the measurement for DA estimations.

42 ENGINEERING↗