Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Structural phase transition causing anomalous photoluminescence behavior in perovskite (C{sub 6}H{sub 11}NH{sub 3}){sub 2}[PbI{sub 4}]

Optical and structural properties of the organic-inorganic hybrid perovskite-type (C{sub 6}H{sub 11}NH{sub 3}){sub 2}[PbI{sub 4}] (abbreviated as C{sub 6}PbI{sub 4}) were investigated using optical absorption, photoluminescence (PL), and x-ray diffraction measurements. Room temperature, optical absorption measurements, performed on spin-coated films of C{sub 6}PbI{sub 4}, revealed two absorption bands at 2.44 and 3.21 eV. Upon 325 nm (3.815 eV) laser irradiation, strong green PL emission peaks were observed at 2.41 eV (P1) and 2.24 eV (P2) and assigned to free and localized excitons, respectively. The exciton binding energy was estimated at 356 meV. At low temperature, two additional emission bands were detected at 2.366 eV (P3) and a large band (LB) at 1.97 eV. The former appeared only below 40 K and the latter emerged below 130 K. The thermal dependence of the PL spectra revealed an abnormal behavior accompanied by singularities in the peak positions and intensities at 40 and 130 K. X-ray diffraction studies performed on powder and single crystals as a function of temperature evidenced significant changes of the interlayer spacing at 50 K and ∼138 K. Around 138 K, a commensurate to incommensurate structural phase transition occurred on cooling. It involves a symmetry breaking leading to a distortion of the PbI{sub 6} octahedron. The resulting incommensurate spatial modulation of the Pb–I distances (and Pb–I–Pb angles) causes a spatial modulation of the band gap, which is at the origin of the emergence of the LB below ∼130 K and the anomalous behavior of the position of P1 below 130 K. The change of the interlayer spacing in the 40-50 K range may in turn be related to the significant decrease of the intensity of P2 and the maximum emission of the LB. These results underline the intricate character of the structural and the PL properties of the hybrid perovskites; understanding such properties should benefit to the design of optoelectronic devices with targeted properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of soiling on Si and CdTe PV modules: Case study in different Brazil climate zones

Soiling, particulate accumulation on photovoltaic (PV) module surfaces, reduces the available solar resource and the resulting generated device power. This case-study summarizes initial results of 5-year research on the contrasting soiling conditions in the tropical, subtropical, and semi-arid climates in Brazil. A major objective is to present a case study of the effects of soiling on PV module performance in different Brazil climate zones that represent the primary areas for the current and expanding Brazil solar installations. For this, the paper presents methodologies to quantify the soiling ratio (SRatio) and soiling rate (SRate) for two representative commercial technologies, polycrystalline or multicrystalline silicon (mc-Si) and thin-film cadmium telluride (CdTe) modules, through soiling monitoring stations deployed in the selected climate regions. An aim is to add to the growing soiling-research knowledge base through addressing these key factors and their relationships to critical electrical, solar resource, thermal, and local meteorological and environmental parameters. This paper presents, evaluates, and compares soiling rates and losses in Belo Horizonte, Minas Gerais (Equatorial Tropical: 19.92° S, 43.99° W), Porto Alegre, Rio Grande do Sul (Humid-Subtropical: 30.05° S, 51.17° W), and Brotas de Macaúbas, Bahia (Semi-Arid: 12.00° S, 42.63° W). The results show that soiling is moderate in all 3-regions, for example with 0.1%/day < SRate < 0.2%/day for Belo Horizonte. Precipitation dominates the cleaning of the modules in the summertime in this climate zone, while it is the major factor year-round in Rio Grande do Sul. Wind is the major issue mitigating the soiling accumulation for the Bahia installation. The methodology incorporates several key refinements, including the normalization and adjustment for the meteorological parameters (temperature, irradiance, wind, precipitation). The evaluations include the region-specific differing effects of non-uniform soiling, natural cleaning, and ambient temperatures.

14 SOLAR ENERGY↗

Magnetic, transport, and structural properties of SrRuO{sub 3} thin films

Thin films of the oxide ferromagnetic metal SrRuO{sub 3} (SRO) are studied, in view of their potential use within oxide-based spin electronic devices. Here, their epitaxial growth on Si-compatible SrTiO{sub 3} substrates is demonstrated by pulsed laser deposition. Detail on their initial, structural, magnetic, and magnetotransport characterisation is also provided. In particular, resistivity and Hall data are interpreted within a two/three carrier model, above T{sub C.} Below T{sub C}, some information about the anisotropy of the Fermi surface effective elipsoids (∼1:4) is recovered. The low-temperature saturation magnetisation approaches 1 μ{sub B}/Ru, with an uniaxial anisotropy of above 0.6 MJm{sup –3}. Despite its low T{sub C} = 160 K, and in view of its relatively low carrier mobility, it is reasoned that SRO could be utilized as the electrode layer in low-temperature all-oxide-MTJ (Magnetic Tunnel Junction) demonstrators and as a seed layer for other ferromagnetic oxides, at and above room temperature.

36 MATERIALS SCIENCE↗

AWE neutron spectrometry results from Godiva-IV (NCERC) characterization - Paper 135

In recent years, it was deemed necessary for the Godiva-IV critical assembly - along with other assemblies collectively forming what is now known as the National Critical Experiments Research Center (NCERC) - to relocate to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). An experiment was proposed (IER-148) under the Nuclear Criticality Safety Program for an international inter-comparison of Nuclear Accident Dosimetry (NAD) using the Godiva-IV assembly, in order to arrest the long term decline in the testing and validation of these systems. Due to the knock-on effect of the change of location on the neutron leakage spectrum, however, new reference points must be established. As a precursor to the intercomparison an additional experiment (IER-147) was proposed with the aim of measuring these reference values for the current Godiva-IV radiation field in the DAF. To establish the reference values Godiva was run in both a sub-critical steady-state mode and a super prompt-critical, pulsed mode. AWE provided neutron spectrometry capabilities in the form of a ROSPEC and Bonner sphere Spectrometer (BSS) for the steady-state experiment, and a Passive Bonner sphere Spectrometer (PBSS) for the pulsed experiment. Neutron leakage spectrum measurements carried out by AWE have been used to determine reference doses around Godiva which can be used for future NAD inter-comparisons. A good comparison of steady-state and pulsed spectra indicates a strong likelihood of being able to relate the power level of both operational methods of the reactor for future work in other fields. Further work is required to determine the fidelity of the thermal peak and it is the intention of AWE to bring additional thermal information to the unfolding process through the incorporation of supplementary activation foils used in the irradiations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A novel process for production of spherical PBT powders and their processing behavior during laser beam melting

Additive manufacturing processes like laser beam melting of polymers are established for production of prototypes and individualized parts. The transfer to other areas of application and to serial production is currently hindered by the limited availability of polymer powders with good processability. Within this contribution a novel process route for the production of spherical polymer micron-sized particles of good flowability has been established and applied to produce polybutylene terephthalate (PBT) powders. Moreover, the applicability of the PBT powders in selective laser beam melting and the dependencies of process parameters on device properties will be outlined. First, polymer micro particles are produced by a novel wet grinding method. To improve the flowability the produced particles the particle shape is optimized by rounding in a heated downer reactor. A further improvement of flowability of the cohesive spherical PBT particles is realized by dry coating. An improvement of flowability by a factor of about 5 is achieved by subsequent rounding of the comminution product and dry-coating as proven by tensile strength measurements of the powders. The produced PBT powders were characterized with respect to their processability. Therefore thermal, rheological, optical and bulk properties were analyzed. Based on these investigations a range of processing parameters was derived. Parameter studies on thin layers, produced in a selective laser melting system, were conducted. Hence appropriate parameters for processing the PBT powders by laser beam melting, like building chamber temperature, scan speed and laser power have been identified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of radiation defects on electrical losses in silicon diodes irradiated with electrons

Silicon diodes with a p{sup +}-n junction irradiated with 3.5-MeV electrons (the fluence ranged from 10{sup 15} to 4 x 10{sup 16} cm{sup -2}) have been studied. It is established that the dependence of the tangent of the angle of electrical losses tan{delta} on the frequency f of alternating current in the range f = 10{sup 2}-10{sup 6} Hz is a nonmonotonic function with two extrema: a minimum and a maximum. Transformation of the dependences tan{delta}(f) as the electron fluence and annealing temperature are increased is caused by a variation in the resistance of n-Si (the base region of the diodes) as a result of accumulation (as the fluence is increased) or disappearance and reconfiguration (in the course of annealing) of radiation defects. The role of time lag of the defect recharging in the formation of tan{delta}(f) is insignificant.

36 MATERIALS SCIENCE↗

Conditions for reliable time-resolved dosimetry of electronic portal imaging devices for fixed-gantry IMRT and VMAT

Purpose: The continuous scanning mode of electronic portal imaging devices (EPID) that offers time-resolved information has been newly explored for verifying dynamic radiation deliveries. This study seeks to determine operating conditions (dose rate stability and time resolution) under which that mode can be used accurately for the time-resolved dosimetry of intensity-modulated radiation therapy (IMRT) beams.Methods: The authors have designed the following test beams with variable beam holdoffs and dose rate regulations: a 10 Multiplication-Sign 10 cm open beam to serve as a reference beam; a sliding window (SW) beam utilizing the motion of a pair of multileaf collimator (MLC) leaves outside the 10 Multiplication-Sign 10 cm jaw; a step and shoot (SS) beam to move the pair in step; a volumetric modulated arc therapy (VMAT) beam. The beams were designed in such a way that they all produce the same open beam output of 10 Multiplication-Sign 10 cm. Time-resolved ion chamber measurements at isocenter and time-resolved and integrating EPID measurements were performed for all beams. The time-resolved EPID measurements were evaluated through comparison with the ion chamber and integrating EPID measurements, as the latter are accepted procedures. For two-dimensional, time-resolved evaluation, a VMAT beam with an infield MLC travel was designed. Time-resolved EPID measurements and Monte Carlo calculations of such EPID dose images for this beam were performed and intercompared.Results: For IMRT beams (SW and SS), the authors found disagreement greater than 2%, caused by frame missing of the time-resolved mode. However, frame missing disappeared, yielding agreement better than 2%, when the dose rate of irradiation (and thus the frame acquisition rates) reached a stable and planned rate as the dose of irradiation was raised past certain thresholds (a minimum 12 s of irradiation per shoot used for SS IMRT). For VMAT, the authors found that dose rate does not affect the frame acquisition rate, thereby causing no frame missing. However, serious inplanar nonuniformities were found. This could be overcome by sacrificing temporal resolution (10 frames or 0.95 s/image): the continuous images agreed with ion chamber responses at the center of EPID and the calculation two-dimensionally in a time-resolved manner.Conclusions: The authors have determined conditions under which the continuous mode can be used for time-resolved dosimetry of fixed-gantry IMRT and VMAT and demonstrated it for VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-462: Impact of the Radiochromic Film Energy Response On Dose Measurements of Low Energy Electronic Brachytherapy Sources

Purpose: We investigated the effect of the EBT3 GafChromicTM film model absorbed dose energy response when used for percent depth dose (PDD) measurements in low-energy photon beams. Methods: We measured PDDs in water from a Xoft 50 kVp source using EBT3 film, and compared them to PDD measurements acquired with a PTW-TN34013 parallel-plate ionization chamber. For the x-ray source, we simulated spectra using the EGSnrc (BEAMnrc) Monte Carlo code, and calculated Half Value Layer (HVL) at different distances from the source in water. Pieces of EBT3 film were irradiated in air and calibration curves were created in terms of air-kerma in air ((Kair)air) for different beam qualities. Pieces of EBT3 film were positioned at distances of 2–6 cm from the Xoft source in a water phantom using a custom-made holder, and irradiated at the same time. As scatter is incorporated in the measured film signal in water, measured (Kair)wat was subsequently converted into absorbed dose to water by the ratio of mass energy absorption coefficients following the AAPM TG-61 dosimetry protocol. Results: Our results show that film calibration curves obtained at beam qualities near the effective energy of the Xoft 50 kVp source in water lead to variation in absorbed dose energy dependence of the response of around 3%. However, if the calibration curve was established at MV beam quality, the error in absorbed dose could be as large as 15%. We observed agreement within 1% between PDD measurements using EBT3 film model (using a calibration curve obtained at 80 kVp, HVL=2.18 mm Al, Eeff=29.5 keV) and the parallel-plate ionization chamber. Conclusion: Accurate dose measurements using radiochromic films at low photon energies require that the radiochromic film dosimetry system be calibrated at corresponding low energies, as large absorbed dose errors are expected for calibrations performed at MV beam qualities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improved Underwater Excitation-Emission Matrix Fluorometer

A compact, high-resolution, two-dimensional excitation-emission matrix fluorometer (EEMF) has been designed and built specifically for use in identifying and measuring the concentrations of organic compounds, including polluting hydrocarbons, in natural underwater settings. Heretofore, most EEMFs have been designed and built for installation in laboratories, where they are used to analyze the contents of samples collected in the field and brought to the laboratories. Because the present EEMF can be operated in the field, it is better suited to measurement of spatially and temporally varying concentrations of substances of interest. In excitation-emission matrix (EEM) fluorometry, fluorescence is excited by irradiating a sample at one or more wavelengths, and the fluorescent emission from the sample is measured at multiple wavelengths. When excitation is provided at only one wavelength, the technique is termed one-dimensional (1D) EEM fluorometry because the resulting matrix of fluorescence emission data (the EEM) contains only one row or column. When excitation is provided at multiple wavelengths, the technique is termed two-dimensional (2D) EEM fluorometry because the resulting EEM contains multiple rows and columns. EEM fluorometry - especially the 2D variety - is well established as a means of simultaneously detecting numerous dissolved and particulate compounds in water. Each compound or pool of compounds has a unique spectral fluorescence signature, and each EEM is rich in information content, in that it can contain multiple fluorescence signatures. By use of deconvolution and/or other mixture-analyses techniques, it is often possible to isolate the spectral signature of compounds of interest, even when their fluorescence spectra overlap. What distinguishes the present 2D EEMF over prior laboratory-type 2D EEMFs are several improvements in packaging (including a sealed housing) and other aspects of design that render it suitable for use in natural underwater settings. In addition, the design of the present 2D EEMF incorporates improvements over the one prior commercial underwater 2D EEMF, developed in 1994 by the same company that developed the present one. Notable advanced features of the present EEMF include the following: 1) High sensitivity and spectral resolution are achieved by use of an off-the-shelf grating spectrometer equipped with a sensor in the form of a commercial astronomical- grade 256 532-pixel charge-coupled-device (CCD) array. 2) All of the power supply, timing, control, and readout circuits for the illumination source and the CCD, ancillary environmental monitoring sensors, and circuitry for controlling a shutter or filter motor are custom-designed and mounted compactly on three circuit boards below a fourth circuit board that holds the CCD (see figure). 3) The compactness of the grating spectrometer, CCD, and circuit assembly makes it possible to fit the entire instrument into a compact package that is intended to be maneuverable underwater by one person. 4) In mass production, the cost of the complete instrument would be relatively low - estimated at approximately $30,000 at 2005 prices.

Moore, Casey↗

The New Sun-Sky-Lunar Cimel CE318-T Multiband Photometer - A Comprehensive Performance Evaluation

This paper presents the new photometer CE318-T, able to perform daytime and night-time photometric measurements using the sun and the moon as light source. Therefore,this new device permits a complete cycle of diurnal aerosol and water vapour measurements valuable to enhance atmospheric monitoring to be extracted. In this study wehave found significantly higher precision of triplets when comparing the CE318-T master instrument and the Cimel AErosol RObotic NET work (AERONET) master (CE318-AERONET) triplets as a result of the new CE318-T tracking system. Regarding the instrument calibration, two new methodologies to transfer the calibration from a reference instrument using only daytime measurements (Sun Ratio and Sun-Moon gain factor techniques) are presented and discussed. These methods allow the reduction of the previous complexities inherent to nocturnal calibration. A quantitative estimation of CE318-T AOD uncertainty by means of error propagation theory during daytime revealed AOD uncertainties (u(sup D)(sub AOD)) for Langley-calibrated instruments similar to the expected values for other reference instruments (0.002-0.009). We have also found u(sup D)(sub AOD) values similar to the values reported in sun photometry for field instruments (approximately 0.015). In the case of the night-time period, the CE318-T-estimated standard combined uncertainty (u(sup N)(sub AOD)) is dependent not only on the calibration technique but also on illumination conditions and the instrumental noise. These values range from 0.011-0.018 for Lunar Langley-calibrated instruments to 0.012-0.021 for instruments calibrated using the Sun Ratio technique. In the case of moon-calibrated instruments using the Sun-Moon gain factor method and sun calibrated using the Langley technique, we found u(sup N)(sub AOD) ranging from 0.016 to 0.017 (up to 0.019 in 440 nm channel), not dependent on any lunar irradiance model. A subsequent performance evaluation including CE318-T and collocated measurements from independent reference instruments has served to assess the CE318-T performance as well as to confirm its estimated uncertainty. Daytime AOD evaluation, performed at Izana station from March to June 2014, encompassed measurements from a reference CE318-T, a CE318-AERONET master instrument, a Precision Filter Radiometer (PFR) and a Precision Spectroradiometer (PSR) prototype, reporting low AOD discrepancies between the four instruments (up to 0.006). The nocturnal AOD evaluation was performed using CE318-T- and starphotometer-collocated measurements and also by means of a day/night coherence transition test using the CE318-T master instrument and the CE318 daytime data from the CE318-AERONET master instrument. Results showed low discrepancies with the star photometer at 870 and 500 nm channels(less tna or equal to 0.013) and differences with AERONET daytime data (1 h after and before sunset and sunrise) in agreement with the estimated u(sup N)(sub AOD) values at all illumination conditions in the case of channels within the visible spectral range, and only for high moon's illumination conditions in the case of near infrared channels. Perceptible water vapour (PWV) validation showed a good agreement between CE318-T and Global Navigation Satellite System (GNSS) PWV values for all illumination conditions, within the expected precision for sun photometry. Finally, two case studies have been included to highlight the ability of the new CE318-T to capture the diurnal cycle of aerosols and water vapour as well as short-term atmospheric variations, critical for climate studies.

Barreto, Africa↗

The efficacy of post porosity plasma protection against vacuum-ultraviolet damage in porous low-k materials

As of today, plasma damage remains as one of the main challenges to the reliable integration of porous low-k materials into microelectronic devices at the most aggressive node. One promising strategy to limit damage of porous low-k materials during plasma processing is an approach we refer to as post porosity plasma protection (P4). In this approach, the pores of the low-k material are filled with a sacrificial agent prior to any plasma treatment, greatly minimizing the total damage by limiting the physical interactions between plasma species and the low-k material. Interestingly, the contribution of the individual plasma species to the total plasma damage is not fully understood. In this study, we investigated the specific damaging effect of vacuum-ultraviolet (v-UV) photons on a highly porous, k = 2.0 low-k material and we assessed the P4 protective effect against them. It was found that the impact of the v-UV radiation varied depending upon the v-UV emission lines of the plasma. More importantly, we successfully demonstrated that the P4 process provides excellent protection against v-UV damage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabrication of Nb/Pb structures through ultrashort pulsed laser deposition

This work reports the fabrication of Nb/Pb structures with an application as photocathode devices. The use of relatively low energy densities for the ablation of Nb with ultrashort pulses favors the reduction of droplets during the growth of the film. However, the use of laser fluences in this ablation regime results in a consequent reduction in the average deposition rate. On the other hand, despite the low deposition rate, the films present a superior adherence to the substrate and an excellent coverage of the irregular substrate surface, avoiding the appearance of voids or discontinuities on the film surface. Moreover, the low energy densities used for the ablation favor the growth of nanocrystalline films with a similar crystalline structure to the bulk material. Therefore, the use of low ablation energy densities with ultrashort pulses for the deposition of the Nb thin films allows the growth of very adherent and nanocrystalline films with adequate properties for the fabrication of Nb/Pb structures to be included in superconducting radiofrequency cavities.

42 ENGINEERING↗

Variable Circular Collimator in Robotic Radiosurgery: A Time-Efficient Alternative to a Mini-Multileaf Collimator?

Purpose: Compared with many small circular beams used in CyberKnife treatments, beam's eye view-shaped fields are generally more time-efficient for dose delivery. However, beam's eye view-shaping devices, such as a mini-multileaf collimator (mMLC), are not presently available for CyberKnife, although a variable-aperture collimator (Iris, 12 field diameters; 5-60 mm) is available. We investigated whether the Iris can mimic noncoplanar mMLC treatments using a limited set of principal beam orientations (nodes) to produce time-efficient treatment plans. Methods and Materials: The data from 10 lung cancer patients and the beam-orientation optimization algorithm 'Cycle' were used to generate stereotactic treatment plans (3 x 20 Gy) for a CyberKnife virtually equipped with a mMLC. Typically, 10-16 favorable beam orientations were selected from 117 available robot node positions using beam's eye view-shaped fields with uniform fluence. Second, intensity-modulated Iris plans were generated by inverse optimization of nonisocentric circular candidate beams targeted from the same nodes selected in the mMLC plans. The plans were evaluated using the mean lung dose, lung volume receiving {>=}20 Gy, conformality index, number of nodes, beams, and monitor units, and estimated treatment time. Results: The mMLC plans contained an average of 12 nodes and 11,690 monitor units. For a comparable mean lung dose, the Iris plans contained 12 nodes, 64 beams, and 21,990 monitor units. The estimated fraction duration was 12.2 min (range, 10.8-13.5) for the mMLC plans and 18.4 min (range, 12.9-28.5) for the Iris plans. In contrast to the mMLC plans, the treatment time for the Iris plans increased with an increasing target volume. The Iris plans were, on average, 40% longer than the corresponding mMLC plans for small targets (<80 cm{sup 3}) and {<=}121% longer for larger targets. For a comparable conformality index, similar results were obtained. Conclusion: For stereotactic lung irradiation, time-efficient and high-quality plans were obtained for robotic-controlled noncoplanar treatments using a mMLC. Iris is a time-efficient alternative for small targets, with similar or better plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomic-scale electrochemistry on the surface of a manganite

The doped manganese oxides (manganites) have been widely studied for their colossal magnetoresistive effects, for potential applications in oxide spintronics, electroforming in resistive switching devices, and are materials of choice as cathodes in modern solid oxide fuel cells. However, little experimental knowledge of the dynamics of the surfaces of perovskite manganites at the atomic scale exists. Here, through in-situ scanning tunnelling microscopy (STM), we demonstrate atomic resolution on samples of La 0.625 Ca 0.375 MnO 3 grown on (001) SrTiO 3 by pulsed laser deposition (PLD). Furthermore, by applying triangular DC waveforms of increasing amplitude to the STM tip, and measuring the tunnelling current, we demonstrate the ability to both perform and monitor surface electrochemical processes at the atomic level, including, for the first time in a manganite, formation of single and multiple oxygen vacancies, disruption of the overlying manganite layers, and removal and deposition of individual atomic units or clusters. Our work paves the way for better understanding of surface oxygen reactions in these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis, Processing, and Use of Isotopically Enriched Epitaxial Oxide Thin Films

Isotopic engineering has emerged as a key approach to study the nucleation, diffusion, phase transitions, and reactions of materials at an atomic level. It aims to uncover mass transport pathways, kinetics, and operational and failure mechanisms of functional materials and devices. Understanding these phenomena leads to deeper insights into important physical processes, such as the transport of ions in energy conversion and storage devices and the role of active sites and supports during heterogeneous catalytic reactions. Likewise, isotopic engineering is being pursued as a means of modifying functionality to enable future technological applications. In this Account, we summarize our recent work employing isotope labeling (e.g., 18 O 2 and 57 Fe) during thin film synthesis and postgrowth processing to reveal growth mechanisms, defect chemistry, and elemental diffusion under working and extreme conditions. Isotope-resolved analysis techniques with nanometer-scale spatial resolution, such as time-of-flight secondary ion mass spectrometry and atom probe tomography, facilitate the accurate quantification of isotopic placement and concentration in our well-defined heterostructures with precisely positioned, isotope-enriched layers. By measuring the nanometer-scale redistribution between natural abundance and isotopically enriched oxygen layers during the deposition of Fe 2 O 3 and Cr 2 O 3 by molecular beam epitaxy, we identified intermixing processes driven by surface adatoms occurring both at the film growth surface and within the first few layers below the surface. Further insights into synthesis mechanisms were gained by studying the tungsten oxide thin films grown by evaporating WO 3 powder in the presence of background 18 O 2 , revealing minimal incorporation of background oxygen during the film formation process. Thermal and radiation-enhanced diffusion in epitaxial Fe and Cr oxides were precisely tracked using 18 O and 57 Fe tracer layers incorporated into model epitaxial oxide thin films. This approach has allowed us to access thermal diffusion behavior at lower temperatures than previously measured, revealing a potential changeover in diffusion mechanism. Understanding radiation-enhanced diffusion in model oxides that represent the surface layers on the structural components of nuclear reactors informs our understanding of their corrosion behavior under irradiation. Isotopic labeling can also provide unique insights into the surface exchange reactions and defect chemistry of electrocatalysts. For instance, tracking the change in 18 O concentration at the surface of an epitaxial LaNiO 3 thin film after the electrocatalytic oxygen evolution reaction revealed the participation of lattice oxygen, confirming a hypothesis that had been proposed previously. Lastly, we highlight a new direction wherein we perform in situ processing studies utilizing isotopic tracers in conjunction with model epitaxial thin films within the atom probe tomography instrument. Additionally, this Account illustrates the great potential of isotopic engineering to enable fundamental mechanistic insights into physical processes and engineer functional properties in epitaxial films, heterostructures, and superlattices.

36 MATERIALS SCIENCE↗

Beyond Californium—A Neutron Generator Alternative for Dosimetry and Instrument Calibration in the U.S.

Many evaluations of neutron survey instruments, area monitors and personal dosimeters rely on neutron reference radiations from 252Cf, a source of spontaneous fission neutrons that produces high dose rates from an almost point source geometry. Its characteristics are generally more favorable when compared to (a,n), photoneutron and reactor-based sources of neutrons. The source is typically used in two standardized configurations: unmoderated, to yield a fission energy spectrum, or placed within a heavy-water moderating sphere to produce a softened spectrum that is more appropriate for evaluating devices used in nuclear power plant work environments. The U.S. Department of Energy (DOE) 252Cf Loan/Lease Program was terminated in 2009, and the replacement of high-activity sources is increasingly cost prohibitive for laboratories that formerly benefited from that program, including the Pacific Northwest National Laboratory (PNNL) and National Institute of Standards and Technology (NIST). Neutron generators, based on the D-T and D-D fusion reactions, are becoming economically competitive with 252Cf and are recognized internationally as important calibration and test standards. Researchers from NIST and PNNLare jointly considering the practicality and technical challenges of implementing neutron generators as calibration standards in the U.S. This article reviews characteristics of isotope-based sources, leading to rationale behind increasing favor of electronically-generated neutron options. The evaluation of a D-T system at PNNL has revealed primary challenges in adapting generators to the task of calibration and testing in which neutron characteristics must be accurately determined. Concepts for modifying the generated neutron spectra to achieve particular targeted spectra, simulating 252Cf or workplace environments, are discussed.

Calibration, californium-252, Dosimeter Irradiatio↗

VALIDATION OF A THERMAL CONDUCTIVITY MEASUREMENT SYSTEM FOR FUEL COMPACTS

A high temperature guarded-comparative-longitudinal heat flow measurement system has been built to measure the thermal conductivity of a composite nuclear fuel compact. It is a steady-state measurement device designed to operate over a temperature range of 300 K to 1200 K. No existing apparatus is currently available for obtaining the thermal conductivity of the composite fuel in a non-destructive manner due to the compact’s unique geometry and composite nature. The current system design has been adapted from ASTM E 1225. As a way to simplify the design and operation of the system, it uses a unique radiative heat sink to conduct heat away from the sample column. A finite element analysis was performed on the measurement system to analyze the associated error for various operating conditions. Optimal operational conditions have been discovered through this analysis and results are presented. Several materials have been measured by the system and results are presented for stainless steel 304, inconel 625, and 99.95% pure iron covering a range of thermal conductivities of 10 W/m*K to 70 W/m*K. A comparison of the results has been made to data from existing literature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a systematic approach for safety assessment of PLD based equipment of I and C systems - 354

Nuclear power plants (NPPs) increasingly apply digital equipment for instrumentation and control (I and C) systems. During the life cycle of NPPs the operators, designers and manufactures are facing the need to replace or upgrade obsolete equipment or to implement new digital I and C systems. A relatively new challenge in this area is the deployment of programmable logic devices (PLDs) for the equipment of I and C systems. Regulatory approval for safety and safety related I and C systems demands confirmation of evidence that design as well as verification and validation (V and V) processes have ensured that the application of new equipment will fulfil safety and reliability requirements and its intended design function. The objective of the recent research project of GRS is developing a systematic approach for the assessment of PLD-based equipment in safety and safety-related I and C systems regarding the fulfilment of regulatory requirements and identification of undesired failure effects. A generic approach for the safety-oriented assessment of PLD-based equipment has been developed, based on the principles of a Plan-Do-Check-Act (PDCA) cycle. The approach comprises planning of the assessment, predefined analysis steps and methodologies, as well as required input information, criteria for decision making process, the tasks concerning identification of improvement potential and determining documentation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗