Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Investigation of Imaging Spent Nuclear Fuel Dry Casks using Cosmic Ray Muons

Recently, the use of cosmic ray muons for cargo scanning applications has been demonstrated and muons have been shown to have the potential to allow for nondestructive assessment of nuclear material accountancy. Relativistic muons have the ability to penetrate dense materials and monitoring the subsequent scattering of muons can provide information about the structure and composition of materials stored in cargo containers. The suitability of cosmic muons for a number of monitoring and imaging applications has been investigated over the years and includes applications to archaeology, volcano imaging, material identification and medical diagnosis. Novel applications of cosmic ray muons have been proposed for examination of comatose patients towards bone density monitoring and also for determination of the molten nuclear fuel location in nuclear reactors having suffered from the effects of a severe accident similar to the one happened in Fukushima. There is a need to develop a capability to monitor nuclear waste and investigate whether the stored content agrees with facility declarations to allow proliferation detection and international treaty verification. Monitoring nuclear waste and controlling nuclear material at its source is one of the main strategies to minimize the risks of nuclear proliferation and reduce potential homeland threats. Since the early 1950's, when the first nuclear power plant began to produce electricity, approximately 65,000 metric tons of spent nuclear fuel have been generated, 25% of which are under dry storage conditions. After the spent nuclear fuel has been placed inside the dry cask, the cask is welded, not allowing for visual inspection. During the long storage life of the cask, intermediate handling and transportation activities take place which does create concerns regarding fuel integrity. Accidents and natural disasters also contribute to this concern. Previous work on spent nuclear fuel dry cask monitoring using muons has shown that the muon scattering distributions are adequately separated and a and a decision rule derived from Bayes' Theorem rendering the classification of different dry casks feasible. Muons present significant advantages over the existing imaging techniques such as the utilization of the passive nature of muons, the lack of radiological sources and consequently the absence of any artificial radiological dose. In the present work, a methodology is developed to demonstrate the applicability of muons for imaging of spent nuclear fuel dry casks. Purpose is to use muons to differentiate between spent nuclear fuel dry casks with different amounts of loading. Monte Carlo simulations of dry casks with different spent nuclear fuel loading are performed to simulate the passage of polyenergetic muons having energies in the range of 1-60 GeV through matter. A 'Muon Generator' is developed to generate muons that follow the actual sea level energy distribution. The 'Muon Generator' is validated against a series of actual spectrum measurements and then coupled with the Monte Carlo particle transport code GEANT4. The accumulated dataset of scattering angles were processed with the Point-of- the-Closest-Approach (PoCA) imaging algorithm and the obtained images demonstrate that an empty dry cask can be clearly distinguished from a half-loaded or a fully loaded one. The apparent separation of the images demonstrates that the muon scattering can be used as a feature for imaging spent nuclear fuel dry casks. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated System for Health Management and Autonomous Control (ISHM-AC) for Cryogenic Operations on the Simulated Propellant Loading System

Autonomous control systems represent a technological barrier from manual and automated operated control systems in an industry wide application. An increase in energy-efficient storage, transfer and use of cryogens and cryogenic propellants on Earth and in space has been observed in space related industries between NASA, government and commercial programs. An increase in efficiency of cryogenic systems demands an increase in the capabilities of the control and monitoring system that manages them. As new technologies are developed for cryogenic systems, complexity and capability increases. The increase in complexities are a natural drive to develop better and more capable health monitoring and control system management. Current research and development efforts lead the Cryogenics Test Laboratory at the Kennedy Space Center to improve its automated control and health monitoring system from a Programmable Logic Control (PLC) based-only system to a fully Integrated System for Health Management (ISHM) - Autonomous Control (AC) capable of performing autonomous operations on a cryogenic propellant transfer system. This ISHM-AC system has been developed and tested by controlling a complete simulated propellant transfer operation. The capabilities and test results of this fully integrated autonomous system for cryogenics propellant transfer operation will be presented in this paper.

Toro Medina, Jaime A.↗

An Autonomic Middleware Solution for Coordinating Multiple QoS Controls

Adaptive self-managing applications can adapt their behavior through components that monitor the application behavior and provide feedback controls. This paper outlines an autonomic approach to coordinate multiple controls for managing service quality using executable control models. In this approach, controls are modeled as process models. Moreover, controls with cross-cutting concerns are provisioned by a dedicated process model. The flexibility of this approach allows composing new controls from existing control components. The coordination of their dependencies is performed within a unified architecture framework for modeling, deploying and executing these models. We integrate the process modeling and execution techniques into a middleware architecture to deliver such features. To demonstrate the practical utilization of this approach, we employ it to manage fail-over and over-loading controls for a service oriented loan brokering application. The empirical results further validate that this solution is not only sensitive to resolving cross-cutting interests of multiple controls, but also lightweight as it incurs low computational overhead.

99 GENERAL AND MISCELLANEOUS↗

On the evolution of elastic properties during laboratory stick‐slip experiments spanning the transition from slow slip to dynamic rupture

Abstract The physical mechanisms governing slow earthquakes remain unknown, as does the relationship between slow and regular earthquakes. To investigate the mechanism(s) of slow earthquakes and related quasi‐dynamic modes of fault slip we performed laboratory experiments on simulated fault gouge in the double direct shear configuration. We reproduced the full spectrum of slip behavior, from slow to fast stick slip, by altering the elastic stiffness of the loading apparatus ( k ) to match the critical rheologic stiffness of fault gouge ( k c ). Our experiments show an evolution from stable sliding, when k > k c , to quasi‐dynamic transients when k ~ k c , to dynamic instabilities when k < k c . To evaluate the microphysical processes of fault weakening we monitored variations of elastic properties. We find systematic changes in P wave velocity ( V p ) for laboratory seismic cycles. During the coseismic stress drop, seismic velocity drops abruptly, consistent with observations on natural faults. In the preparatory phase preceding failure, we find that accelerated fault creep causes a V p reduction for the complete spectrum of slip behaviors. Our results suggest that the mechanics of slow and fast ruptures share key features and that they can occur on same faults, depending on frictional properties. In agreement with seismic surveys on tectonic faults our data show that their state of stress can be monitored by V p changes during the seismic cycle. The observed reduction in V p during the earthquake preparatory phase suggests that if similar mechanisms are confirmed in nature high‐resolution monitoring of fault zone properties may be a promising avenue for reliable detection of earthquake precursors.

Tinti, E.↗

$\mathrm{RADICAL}$-Pilot and $\mathrm{PMIx}$/$\mathrm{PRRTE}$: Executing Heterogeneous Workloads at Large Scale on Partitioned $\mathrm{HPC}$ Resources

Execution of heterogeneous workflows on high-performance computing (HPC) platforms present unprecedented resource management and execution coordination challenges for runtime systems. Task heterogeneity increases the complexity of resource and execution management, limiting the scalability and efficiency of workflow execution. Re-source partitioning and distribution of tasks execution over portioned re-sources promises to address those problems but we lack an experimental evaluation of its performance at scale. Here this paper provides a performance evaluation of the Process Management Interface for Exascale (PMIx) and its reference implementation PRRTE on the leadership-class HPC plat-form Summit, when integrated into a pilot-based runtime system called RADICAL-Pilot. We partition resources across multiple PRRTE Distributed Virtual Machine (DVM) environments, responsible for launching tasks via the PMIx interface. We experimentally measure the work-load execution performance in terms of task scheduling/launching rate and distribution of DVM task placement times, DVM startup and termination overheads on the Summit leadership-class HPC platform. Integrated solution with PMIx/PRRTE enables using an abstracted, standardized set of interfaces for orchestrating the launch process, dynamic process management and monitoring capabilities. It extends scaling capabilities allowing to overcome a limitation of other launching mechanisms (e.g., JSM/LSF). Explored different DVM setup configurations provide insights on DVM performance and a layout to leverage it. Our experimental results show that heterogeneous workload of 65,500 tasks on 2048 nodes, and partitioned across 32 DVMs, runs steady with resource utilization not lower than 52%. While having less concurrently executed tasks resource utilization is able to reach up to 85%, based on results of heterogeneous workload of 8200 tasks on 256 nodes and 2 DVMs.

97 MATHEMATICS AND COMPUTING↗

Design and application of electromechanical actuators for deep space missions

During the period 8/16/92 through 2/15/93, work has been focused on three major topics: (1) screw modeling and testing; (2) motor selection; and (3) health monitoring and fault diagnosis. Detailed theoretical analysis has been performed to specify a full dynamic model for the roller screw. A test stand has been designed for model parameter estimation and screw testing. In addition, the test stand is expected to be used to perform a study on transverse screw loading.

Haskew, Tim A.↗

A precision mechanical nerve stimulator

An electromechanical device, used to apply and monitor stimulating pulses to a mammalian motor nerve, has been successfully developed at NASA Langley Research Center. Two existing force transducers, a flight skin friction balance and a miniature skin friction balance which were designed for making aerodynamic drag measurements, were modified and incorporated to form this precision instrument. The nerve stimulator is a type one servomechanism capable of applying and monitoring stimulating pulses of 0 to 10 grams with a precision of better than +/- 0.05 grams. Additionally, the device can be independently used to apply stimulating pulses by displacing the nerve from 0 to 0.25 mm with a precision of better than +/- 0.001 mm while measuring the level of the load applied.

Tcheng, Ping↗

Isothermal Damage and Fatigue Behavior of SCS-6/Timetal 21S [0/90](Sub S) Composite at 650 Deg C

The isothermal fatigue damage and life behaviors of SCS-6/Timetal 21S (0/90)s were investigated at 650 C. Strain ratcheting and degradation of the composite's static elastic modulus were carefully monitored as functions of cycles to indicate damage progression. Extensive fractographic and metallographic analyses were conducted to determine damage/failure mechanisms. Resulting fatigue lives show considerable reductions in comparison to (0) reinforced titanium matrix composites subjected to comparable conditions. Notable stiffness degradations were found to occur after the first cycle of loading, even at relatively low maximum stress levels, where cyclic lives are greater than 25,000 cycles. This was attributed to the extremely weak fiber/matrix bond which fails under relatively low transverse loads. Stiffness degradations incurred on first cycle loadings and degradations thereafter were found to increase with increasing maximum stress. Environmental effects associated with oxidation of the (90) fiber interfaces clearly played a role in the damage mechanisms as fracture surfaces revealed environment assisted matrix cracking along the (90) fibers. Metallographic analysis indicated that all observable matrix fatigue cracks initiated at the (90) fiber/matrix interfaces. Global de-bonding in the loading direction was found along the (90) fibers. No surface initiated cracks were evident and minimal if any (0) fiber cracking was visible.

Castelli, Michael G.↗

Improving Small Signal Stability through Operating Point Adjustment

ModeMeter techniques for real-time small signal stability monitoring continue to mature, and more and more phasor measurements are available in power systems. It has come to the stage to bring modal information into real-time power system operation. This paper proposes to establish a procedure for Modal Analysis for Grid Operations (MANGO). Complementary to PSS’s and other traditional modulation-based control, MANGO aims to provide suggestions such as increasing generation or decreasing load for operators to mitigate low-frequency oscillations. Different from modulation-based control, the MANGO procedure proactively maintains adequate damping for all time, instead of reacting to disturbances when they occur. Effect of operating points on small signal stability is presented in this paper. Implementation with existing operating procedures is discussed. Several approaches for modal sensitivity estimation are investigated to associate modal damping and operating parameters. The effectiveness of the MANGO procedure is confirmed through simulation studies of several test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Different Vein Catheter Sizes for Mechanical Power Injection in CT: In Vitro Evaluation with Use of a Circulation Phantom

The purpose of this study was to evaluate the influence of different peripheral vein catheter sizes on the injection pressure, flow rate, injection duration, and intravascular contrast enhancement. A flow phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used. High-iodine-concentration contrast medium (370 mg iodine/ml; Ultravist 370) was administered in the venous compartment through peripheral vein catheters of different sizes (14, 16, 18, 20, 22, and 24 G) using a double-head power injector with a pressure limit of 325 psi. The flow rate was set to 5 ml/s, with a total iodine load of 36 g for all protocols. Serial CT scans at the level of the pulmonary artery and the ascending and the descending aorta replica were obtained. The true injection flow rate, injection pressure, injection duration, true contrast material volume, and pressure in the phantom during and after injection were continuously monitored. Time enhancement curves were computed and both pulmonary and aortic peak time and peak enhancement were determined. Using peripheral vein catheters with sizes of 14-20 G, flow rates of approximately 5 ml/s were obtained. During injection through a 22-G catheter the pressure limit was reached and the flow rate was decreased, with a consecutive decreased pulmonary and aortic contrast enhancement compared to the 14- to 20-G catheters. Injection through a 24-G peripheral vein catheter was not possible because of disconnection of the canula due to the high flow rate and pressure. In summary, intravenous catheters with sizes of 14-20 G are suitable for CT angiography using an injection protocol with a high flow rate and a high-iodine-concentration contrast medium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model predictive control for voltage restoration in microgrids using temporal logic specifications

Power system operation will encounter numerous voltage variabilities as the proliferation of renewable energy continues. Real-time monitoring and communication technologies can potentially improve voltage stability by enabling the rapid detection of voltage deviations and the implementation of corrective actions. These corrective actions will only be effective in restoring stability if they are chosen in a timely and scalable manner. This paper considers the problem of power systems’ load voltage control in order to simultaneously address both magnitude and time voltage specifications. In order to comply with grid codes and avoid unnecessary relay protection actions, a model predictive control (MPC)-based control strategy employing temporal logic specifications (TLSs) is proposed. The TLSs strategy is introduced as a formalism to control the voltage variation at a critical load bus against operational bounds over time. The control objective is to schedule optimal control input signals from the available supportive energy storage systems, which provide reactive power injections, leading to satisfying the specified finite-time restoration described by the TLSs with minimal control efforts. The simulation results display that the TLSs strategy for power systems’ voltage control synthesis is extremely significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extending the Fermi -LAT data processing pipeline to the grid

The Data Handling Pipeline ("Pipeline") has been developed for the Fermi Gamma-Ray Space Telescope (Fermi) Large Area Telescope (LAT) which launched in June 2008. Since then it has been in use to completely automate the production of data quality monitoring quantities, reconstruction and routine analysis of all data received from the satellite and to deliver science products to the collaboration and the Fermi Science Support Center. Aside from the reconstruction of raw data from the satellite (Level 1), data reprocessing and various event-level analyses are also reasonably heavy loads on the pipeline and computing resources. These other loads, unlike Level 1, can run continuously for weeks or months at a time. Additionally, it receives heavy use in performing production Monte Carlo tasks.

ASTRO↗

Preload Characterization of Short Models of MQXF the Nb 3 Sn Low-β Quadrupole for the Hi-Lumi LHC

MQXF is the Nb3Sn Low-β Quadrupole magnet that the HL-LHC project is planning to install in the LHC interaction regions in 2026 as part of an upgrade to increase the LHC inte-grated luminosity by about a factor of ten. The magnet will be fab-ricated in two different lengths: 4.2 m for MQXFA, built in the US by the Accelerator Upgrade Project (AUP), and 7.15 m for MQXFB, fabricated by CERN. In order to qualify the magnet de-sign and characterize its performance with different conductors, cable geometries and pre-load configuration, five short model magnets, called MQXFS, were fabricated, assembled and tested. The latest model, MQXFS6, uses a new powder-in-tube (PIT) su-perconducting wire, featuring a bundle barrier surrounding the filaments. The coil and the support structure were equipped with strain gauges and optical fibres to monitor strain during assembly, cool-down and excitation. In this paper we further develop the conventional azimuthal preload analysis and introduce a new set of tools for MQXF coil pack characterization which we use to an-alyse the behaviour of MQXFS6 room temperature preload and to reanalyse all the short models tested at CERN. A comparison is made between all the studied magnets revealing new characteriz-ing preload parameters.

43 PARTICLE ACCELERATORS↗

Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support

This project was created from a partnership between the U.S. Department of Energy’s (DOE’s) Building America research team IBACOS, Inc. and Imagine Homes, a production homebuilder of high-performance homes in San Antonio, Texas—a hot-humid climate. The primary purpose was to evaluate the performance of a multihead mini-split heat pump (MSHP) space-conditioning system, which consists of ducted and ductless indoor units, in maintaining uniform comfort in an occupied test house. The research team evaluated the MSHP space-conditioning strategy for its effectiveness in achieving uniform temperature and relative humidity (RH) levels throughout the test house and for overall constructability and cost. This evaluation was based on data that were collected from short-term tests and monitoring during 1 year of occupancy, as well as from builder and occupant feedback. Design considerations for integrating an MSHP system into the builder’s full range of production home designs were also explored, with a focus on minimizing the cost and complexity of the system design while meeting the thermal loads of the house and providing occupant comfort according to ANSI/ASHRAE Standard 55-2010 (ASHRAE 2010a).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling of SAW Delay Lines

Integrated Vehicle Health Monitoring (IVHM) of aerospace vehicles requires rugged sensors having reduced volume, mass, and power that can be used to measure a variety of phenomena. Wireless systems are preferred when retro-fitting sensors onto existing vehicles. Surface Acoustic Wave (SAW) devices are capable of sensing: temperature, pressure, strain, chemical species, mass loading, acceleration, and shear stress. SAW technology is low cost, rugged, lightweight, and extremely low power. To aid in the development of SAW sensors for IVHM applications, a first order model of a SAW Delay line has been created.

Wilson, William C.↗

Multimodal Neurodiagnostic Tool for Exploration Missions

Linea Research Corporation has developed a neurodiagnostic tool that detects behavioral stress markers for astronauts on long-duration space missions. Lightweight and compact, the device is unobtrusive and requires minimal time and effort for the crew to use. The system provides a real-time functional imaging of cortical activity during normal activities. In Phase I of the project, Linea Research successfully monitored cortical activity using multiparameter sensor modules. Using electroencephalography (EEG) and functional near-infrared spectroscopy signals, the company obtained photoplethysmography and electrooculography signals to compute the heart rate and frequency of eye movement. The company also demonstrated the functionality of an algorithm that automatically classifies the varying degrees of cognitive loading based on physiological parameters. In Phase II, Linea Research developed the flight-capable neurodiagnostic device. Worn unobtrusively on the head, the device detects and classifies neurophysiological markers associated with decrements in behavior state and cognition. An automated algorithm identifies key decrements and provides meaningful and actionable feedback to the crew and ground-based medical staff.

Lee, Yong Jin↗

The stress corrosion cracking behavior of alloys 690 and 152 WELD in a PWR environment.

Alloys 690 and 152 are the replacement materials of choice for Alloys 600 and 182, respectively. The latter two alloys are used as structural materials in pressurized water reactors (PWRs) and have been found to undergo stress corrosion cracking (SCC). The objective of this work is to determine the crack growth rates (CGRs) in a simulated PWR water environment for the replacement alloys. The study involved Alloy 690 cold-rolled by 26% and a laboratory-prepared Alloy 152 double-J weld in the as-welded condition. The experimental approach involved pre-cracking in a primary water environment and monitoring the cyclic CGRs to determine the optimum conditions for transitioning from the fatigue transgranular to intergranular SCC fracture mode. The cyclic CGRs of cold-rolled Alloy 690 showed significant environmental enhancement, while those for Alloy 152 were minimal. Both materials exhibited SCC of 10{sup -11} m/s under constant loading at moderate stress intensity factors. The paper also presents tensile property data for Alloy 690TT and Alloy 152 weld in the temperature range 25--870 C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗