Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONITOR PROGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

A programming model performance study using the NAS parallel benchmarks

Harnessing the power of multicore platforms is challenging due to the additional levels of parallelism present. In this paper we use the NAS Parallel Benchmarks to study three programming models, MPI, OpenMP and PGAS to understand their performance and memory usage characteristics on current multicore architectures. To understand these characteristics we use the Integrated Performance Monitoring tool and other ways to measure communication versus computation time, as well as the fraction of the run time spent in OpenMP. The benchmarks are run on two different Cray XT5 systems and an Infiniband cluster. Our results show that in general the three programming models exhibit very similar performance characteristics. In a few cases, OpenMP is significantly faster because it explicitly avoids communication. For these particular cases, we were able to re-write the UPC versions and achieve equal performance to OpenMP. Using OpenMP was also the most advantageous in terms of memory usage. Also we compare performance differences between the two Cray systems, which have quad-core and hex-core processors.We show that at scale the performance is almost always slower on the hex-core system because of increased contention for network resources.

97 MATHEMATICS AND COMPUTING↗

Optimizing DOE Opportunities to Research Land–Atmosphere Interactions in the U.S. Southeast (Workshop Report)

The southeastern United States (Southeast), with its complex and varied environments, is an area of tremendous economic, ecological, and societal importance to the country. The region is characterized by heterogeneous landscapes (i.e., geology and soil type) and a long history of human land use coupled with a warm temperature regime and high precipitation. As a result, soil erosion and deposition are pronounced, vegetation recovery is rapid, and human modification is extensive across the region. To better understand land–atmosphere interactions in this important and complex region, research communities supported by the U.S. Department of Energy’s Biological and Environmental Research (BER) program identified the Southeast as a priority region of interest. In fall 2024, the third Atmospheric Radiation Measurement Mobile Facility (AMF3), one of three mobile monitoring facilities designed to collect atmospheric and climate data from undersampled regions around the world, will begin operations in northwestern Alabama’s Bankhead National Forest (BNF). The AMF3-BNF 5-year deployment, from 2024–2029, will monitor the effects of feedbacks among aerosols, clouds, and precipitation on plant physiology and canopy-scale fluxes. It will also focus on scale aggregation to resolve the role of local forcing on larger-scale processes. To enable broader AMF3 involvement by the science community, the BER Environmental System Science (ESS) program organized the Southeast Land– Atmosphere Research Opportunities (SELARO) workshop in August 2023. The purpose was to identify gaps in scientific understanding of terrestrial processes in the Southeast (defined as states bounded by the Gulf of Mexico to the south, the Atlantic Ocean to east, the Mississippi River to the west, and extending through Tennessee and North Carolina to the north) and explore opportunities to use the AMF3-BNF deployment to coordinate and leverage research efforts across the region. Many parts of the Southeast have experienced repeated anthropogenic forcings. Farming, hunting, burning, and settlement of the region by Indigenous Peoples first shaped the distribution of plant communities, which in turn influenced European colonization patterns. Timber harvesting was common during the expansion of European settlements, and production forestry continues today. Agricultural production was extensive and then waned through the 20th century, creating a period of afforestation following agricultural abandonment. Today, many formerly agricultural landscapes are undergoing rapid urbanization and suburbanization. Overlying these patterns of anthropogenic land use are frequent disturbances from hurricanes, tornadoes, wildfires, drought, flooding, ice storms, and the occasional blizzard. An additional characteristic of the Southeast is its overall landscape complexity. Unlike the western United States, where broad expanses may share similar characteristics, Southeast topography, drainage patterns, vegetation, and development patterns vary widely across relatively small spatial scales (<1 km). This is due to the region’s underlying geology and soil development, species biodiversity patterns, and land ownership and use coupled with strong forces of erosion, weathering, and rapid plant growth in the warm, wet climate.

54 ENVIRONMENTAL SCIENCES↗

WE-H-209-00: Carson/Zagzebski Distinguished Lectureship: Image Guided Ultrasound Therapy

Focused ultrasound has been shown to be the only method that allows noninvasive thermal coagulation of tissues and recently this potential has been explored for image-guided drug delivery. In this presentation, the advances in ultrasound phased array technology for energy delivery, exposure monitoring and control will be discussed. Experimental results from novel multi-frequency transmit/receive arrays will be presented. In addition, the feasibility of fully electronically focused and steered high power arrays with many thousands of transducer elements will be discussed. Finally, some of the recent clinical and preclinical results for the treatment of brain disease will be reviewed. Learning Objectives: Introduce FUS therapy principles and modern techniques Discuss use of FUS for drug delivery Cover the technology required to deliver FUS and monitor therapy Present clinical examples of the uses of these techniques This research was supported by funding from The Canada Research Chair Program, Grants from CIHR and NIH (no. EB003268).; K. Hynynen, Canada Foundation for Innovation; Canadian Institutes of Health Research; Focused Ultrasound Surgery Foundation; Canada Research Chair Program; Natural Sciences and Engineering Research Council of Canada; Ontario Research Fund; National Institutes of Health; Canadian Cancer Society Research Institute; The Weston Brain Institute; Harmonic Medical; Focused Ultrasound Instruments.

60 APPLIED LIFE SCIENCES↗

WE-H-209-01: Advances in Ultrasound Therapy

Focused ultrasound has been shown to be the only method that allows noninvasive thermal coagulation of tissues and recently this potential has been explored for image-guided drug delivery. In this presentation, the advances in ultrasound phased array technology for energy delivery, exposure monitoring and control will be discussed. Experimental results from novel multi-frequency transmit/receive arrays will be presented. In addition, the feasibility of fully electronically focused and steered high power arrays with many thousands of transducer elements will be discussed. Finally, some of the recent clinical and preclinical results for the treatment of brain disease will be reviewed. Learning Objectives: Introduce FUS therapy principles and modern techniques Discuss use of FUS for drug delivery Cover the technology required to deliver FUS and monitor therapy Present clinical examples of the uses of these techniques This research was supported by funding from The Canada Research Chair Program, Grants from CIHR and NIH (no. EB003268).; K. Hynynen, Canada Foundation for Innovation; Canadian Institutes of Health Research; Focused Ultrasound Surgery Foundation; Canada Research Chair Program; Natural Sciences and Engineering Research Council of Canada; Ontario Research Fund; National Institutes of Health; Canadian Cancer Society Research Institute; The Weston Brain Institute; Harmonic Medical; Focused Ultrasound Instruments.

60 APPLIED LIFE SCIENCES↗

Ten million and one penguins, or, lessons learned from booting millions of virtual machines on HPC systems.

In this paper we describe Megatux, a set of tools we are developing for rapid provisioning of millions of virtual machines and controlling and monitoring them, as well as what we've learned from booting one million Linux virtual machines on the Thunderbird (4660 nodes) and 550,000 Linux virtual machines on the Hyperion (1024 nodes) clusters. As might be expected, our tools use hierarchical structures. In contrast to existing HPC systems, our tools do not require perfect hardware; that all systems be booted at the same time; and static configuration files that define the role of each node. While we believe these tools will be useful for future HPC systems, we are using them today to construct botnets. Botnets have been in the news recently, as discoveries of their scale (millions of infected machines for even a single botnet) and their reach (global) and their impact on organizations (devastating in financial costs and time lost to recovery) have become more apparent. A distinguishing feature of botnets is their emergent behavior: fairly simple operational rule sets can result in behavior that cannot be predicted. In general, there is no reducible understanding of how a large network will behave ahead of 'running it'. 'Running it' means observing the actual network in operation or simulating/emulating it. Unfortunately, this behavior is only seen at scale, i.e. when at minimum 10s of thousands of machines are infected. To add to the problem, botnets typically change at least 11% of the machines they are using in any given week, and this changing population is an integral part of their behavior. The use of virtual machines to assist in the forensics of malware is not new to the cyber security world. Reverse engineering techniques often use virtual machines in combination with code debuggers. Nevertheless, this task largely remains a manual process to get past code obfuscation and is inherently slow. As part of our cyber security work at Sandia National Laboratories, we are striving to understand the global network behavior of botnets. We are planning to take existing botnets, as found in the wild, and run them on HPC systems. We have turned to HPC systems to support the creation and operation of millions of Linux virtual machines as a means of observing the interaction of the botnet and other noninfected hosts. We started out using traditional HPC tools, but these tools are designed for a much smaller scale, typically topping out at one to ten thousand machines. HPC programming libraries and tools also assume complete connectivity between all nodes, with the attendant configuration files and data structures to match; this assumption holds up very poorly on systems with millions of nodes.

99 GENERAL AND MISCELLANEOUS↗

Temporal Characterization of Hydrates System Dynamics beneath Seafloor Mounds. Integrating Time-Lapse Electrical Resistivity Methods and In Situ Observations of Multiple Oceanographic Parameters

This study was designed to investigate temporal variations in hydrate system dynamics by measuring changes in volumes of hydrate beneath hydrate-bearing mounds on the continental slope of the northern Gulf of Mexico, the landward extreme of hydrate occurrence in this region. Direct Current Resistivity (DCR) measurements were made contemporaneously with measurements of oceanographic parameters at Woolsey Mound, a carbonate-hydrate complex on the mid-continental slope, where formation and dissociation of hydrates are most vulnerable to variations in oceanographic parameters affected by climate change, and where changes in hydrate stability can readily translate to loss of seafloor stability, impacts to benthic ecosystems, and venting of greenhouse gases to the water-column, and eventually, the atmosphere. We focused our study on hydrate within seafloor mounds because the structurally-focused methane flux at these sites likely causes hydrate formation and dissociation processes to occur at higher rates than at sites where the methane flux is less concentrated and we wanted to maximize our chances of witnessing association/dissociation of hydrates. We selected a particularly well-studied hydrate-bearing seafloor mound near the landward extent of the hydrate stability zone, Woolsey Mound (MC118). This mid-slope site has been studied extensively and the project was able to leverage considerable resources from the team’s research experience at MC118. The site exhibits seafloor features associated with gas expulsion, hydrates have been documented at the seafloor, and changes in the outcropping hydrates have been documented, photographically, to have occurred over a period of months. We conducted observatory-based, in situ measurements to 1) characterize, geophysically, the sub-bottom distribution of hydrate and its temporal variability, and 2) contemporaneously record relevant environmental parameters (temperature, pressure, salinity, turbidity, bottom currents) to detect short-term changes within the hydrates system, identify relationships/impacts of local oceanographic parameters on the hydrates system, and improve our understanding of how seafloor instability is affected by hydrates-driven changes. A 2009 DCR survey of MC118 demonstrated that we could image resistivity anomalies to a depth of 75m below the seafloor in water depths of 1km. We reconfigured this system to operate autonomously on the seafloor in a pre-programmed mode, for periods of months. We designed and built a novel seafloor lander and deployment capability that would allow us to investigate the seafloor at potential deployment sites and deploy instruments only when conditions met our criteria. This lander held the DCR system, controlling computers, and battery power supply, as well as instruments to record oceanographic parameters. During the first of two cruises to the study site, we conducted resistivity surveying, selected a monitoring site, and deployed the instrumented lander and DCR, centered on what appeared to be the most active locations within the site, programmed to collect a DCR profile, weekly. After a 4.5-month residence on the seafloor, the team recovered all equipment. Unfortunately, several equipment failures occurred prior to recovery of the instrument packages. Prior to the failures, however, two resistivity profiles were collected together with oceanographic data. Results show, unequivocally, that significant changes can occur in both hydrate volume and distribution during time periods as brief as one week. Occurrences appear to be controlled by both deep and near-surface structure. Results have been integrated with seismic data from the area and show correspondence in space of hydrate and structures, including faults and gas chimneys.

58 GEOSCIENCES↗

SU-E-T-372: Evaluation and Comparison of Second-Check Monitor Unit Calculation Software with Pinnacle Treatment Planning System

Purpose: The purpose of this study was to evaluate and compare the accuracy of dose calculation algorithms in the second check software programs Radcalc, Diamond, IMSure, and MUcheck, against the Pinnacle3 treatment planning system (TPS). Methods: Baseline accuracy of the second check software was established by comparison against Pinnacle TPS data using open square fields of 5, 10, 20, 30 and 40cm in a SAD setup. 18 previously treated patients’ files were exported from the Pinnacle3 TPS to each of the four second check softwares, consisting of 146 step and shoot intensity modulated radiotherapy (IMRT) beams and 60 Smart Arcs. Monitor unit (MU) calculated in each of the software were compared with the TPS and the values were represented as a percent difference. Open fields were calculated as a baseline for each software’s accuracy using 5×5, 10×10, 20×20, 30×30, and 40×40 fields. Box plots, Pearson correlation, and Bland-Altman analysis were used for comparison of the results. Results: The baseline accuracy was established to within 0.6%, −1.4%, −0.2%, and −1.0% for Diamond, IMSure,MUcheck, and Radcalc, respectively. In the clinical data, the dose difference represented as mean ± 1 standard deviation were 0.7%±0.1%, −0.3%±0.1%, −1.5%±0.1%, and 0.4%±0.0% for Diamond, IMSure, MUcheck, and Radcalc, respectively Conclusion: The implementation of Clarkson algorithm for the dose calculation between each of the software in question can vary considerably. The currently used second check software, Radcalc has shown the best agreement on average, variance, and smallest percent range from Pinnacle3 TPS values. The closest in average percent difference from the TPS data was the IMSure software, but has significantly larger variance and percent range. The mean percent differences in Diamond and MUcheck were significantly larger than Radcalc and IMSure.

60 APPLIED LIFE SCIENCES↗

Experimental particle physics research at Texas Tech University

The high energy physics group at Texas Tech University (TTU) concentrates its research efforts on the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) and on generic detector R&D for future applications. Our research programs have been continuously supported by the US Department of Energy for over two decades, and this final report summarizes our achievements during the last grant period from May 1, 2012 to March 31, 2016. After having completed the Run 1 data analyses from the CMS detector, including the discovery of the Higgs boson in July 2012, we concentrated on commissioning the CMS hadron calorimeter (HCAL) for Run 2, performing analyses of Run 2 data, and making initial studies and plans for the second phase of upgrades in CMS. Our research has primarily focused on searches for Beyond Standard Model (BSM) physics via dijets, monophotons, and monojets. We also made significant contributions to the analyses of the semileptonic Higgs decays and Standard Model (SM) measurements in Run 1. Our work on the operations of the CMS detector, especially the performance monitoring of the HCAL in Run 1, was indispensable to the experiment. Our team members, holding leadership positions in HCAL, have played key roles in the R&D, construction, and commissioning of these detectors in the last decade. We also maintained an active program in jet studies that builds on our expertise in calorimetry and algorithm development. In Run 2, we extended some of our analyses at 8 TeV to 13 TeV, and we also started to investigate new territory, e.g., dark matter searches with unexplored signatures. The objective of dual-readout calorimetry R&D was intended to explore (and, if possible, eliminate) the obstacles that prevent calorimetric detection of hadrons and jets with a comparable level of precision as we have grown accustomed to for electrons and photons. The initial prototype detector was successfully tested at the SPS/CERN in 2003-2004 and evolved over the last decade. In 2012-2015, several other prototypes were built to further reduce leakage fluctuations, improve Cherenkov light yield, increase fiber attenuation length, and other related phenomena. During this grant period, we graduated two students with Ph.D. degrees, and five undergraduate students from our labs went on to prestigious graduate programs in the US and Europe. Also, the TTU HEP team has participated in the QuarkNet program every year since 2001. We are dedicated to working with area teachers and students at all levels and to training the next generation of scientists. Over 20 high school teachers have participated in our program since its inception.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring FLOPS Using Hardware Performance Counter Technologies on LC systems

FLOPS (FLoating-point Operations Per Second) is a commonly used performance metric for scientific programs that rely heavily on floating-point (FP) calculations. The metric is based on the number of FP operations rather than instructions, thereby facilitating a fair comparison between different machines. A well-known use of this metric is the LINPACK benchmark that is used to generate the Top500 list. It measures how fast a computer solves a dense N by N system of linear equations Ax=b, which requires a known number of FP operations, and reports the result in millions of FP operations per second (MFLOPS). While running a benchmark with known FP workloads can provide insightful information about the efficiency of a machine's FP pipelines in relation to other machines, measuring FLOPS of an arbitrary scientific application in a platform-independent manner is nontrivial. The goal of this paper is twofold. First, we explore the FP microarchitectures of key processors that are underpinning the LC machines. Second, we present the hardware performance monitoring counter-based measurement techniques that a user can use to get the native FLOPS of his or her program, which are practical solutions readily available on LC platforms. By nature, however, these native FLOPS metrics are not directly comparable across different machines mainly because FP operations are not consistent across microarchitectures. Thus, the first goal of this paper represents the base reference by which a user can interpret the measured FLOPS more judiciously.

99 GENERAL AND MISCELLANEOUS↗

Fluid geochemistry at the Raft River geothermal field, Idaho, USA: New data and hydrogeological implications

Following a period of exploration and development in the mid-late 1970’s, there was little activity at the Raft River geothermal field for the next ~20 years. U.S. Geothermal Inc. acquired the project in 2002, and began commercial power generation in January 2008. From mid-2004 to present, U.S. Geothermal Inc. has collected geochemical data from geothermal and monitoring wells in the field, as well as other shallow wells in the area. An additional sampling program was completed in July 2010 to measure a wider range of trace elements and key water isotopes (δ 18 O, δD, and 3 H (Tritium)) in the field. The data indicate that the fluid geochemistry in the field is spatially variable and complex, with two distinct deep geothermal fluid types (high vs. low K, Na, Cl, Ca, Li, F concentrations) and two groundwater fluid types. These differences have been interpreted to reflect deep structural controls on fluid pathways in the field, which has compartmentalized the fluids and limited the degree of mixing between them.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an ADC radiation tolerance characterization system for the upgrade of the ATLAS LAr calorimeter

ATLAS LAr calorimeter will undergo its Phase-I upgrade during the long shutdown (LS2) in 2018, and a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multi-channel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for the LTDB. Here, to evaluate the radiation tolerance of these backup commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, with ADC drivers and clock distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as a DAQ board. The data from the ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed with Python, and all the commands are sent to the DAQ board through Gigabit Ethernet by this program. Two ADC boards have been designed for the ADC, ADS52J90 from Texas Instruments and AD9249 from Analog Devices respectively. TID tests for both ADCs have been performed at BNL, and an SEE test for the ADS52J90 has been performed at Massachusetts General Hospital (MGH). Test results have been analyzed and presented. The test results demonstrate that this test system is very versatile, and works well for the radiation tolerance characterization of commercial multi-channel high-speed ADCs for the upgrade of the ATLAS LAr calorimeter. It is applicable to other collider physics experiments where radiation tolerance is required as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bringing Automated Fault Detection and Diagnostics Tools for HVAC&R Into the Mainstream

Heating, ventilation, and air-conditioning (HVAC) systems consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. commercial buildings. Additionally, commercial refrigeration (R) systems add about 1 quad to commercial buildings energy consumption. Most HVAC systems operate with one or more faults that result in increased energy consumption. Fault detection and diagnostics (FDD) tools have been developed to address this national issue, and many tools are commercially available. FDD tools have the potential to save considerable energy for an existing commercial rooftop unit (RTU) and refrigeration systems. These devices can be used for both retro commissioning and, when faults are addressed, continuous commissioning. However, there appears to be multiple market barriers for this technology. Although there are efforts to develop FDD tool standards, currently there are no standards and methods to define functions, capabilities, accuracy, and reliability of FDD tools in the field. Moreover, most of the commercial FDD tools have not been verified in the field independently. This paper presents a comprehensive approach for bringing HVAC FDD tools into the mainstream. The approach involves demonstrating ten commercially available FDD tools installed at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying and assessing market barriers, creating a process evaluation methodology, and assisting utility companies in developing incentive programs. Furthermore, the preliminary baseline results from the case study demonstrate how the use of an independent monitoring system (IMS) can be used for ground-truth in evaluating FDD tools in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-T-20: A Correlation Study of 2D and 3D Gamma Passing Rates for Prostate IMRT Plans

Purpose: To investigate the correlation between the two-dimensional gamma passing rate (2D %GP) and three-dimensional gamma passing rate (3D %GP) in prostate IMRT quality assurance. Methods: Eleven prostate IMRT plans were randomly selected from the clinical database and were used to obtain dose distributions in the phantom and patient. Three types of delivery errors (MLC bank sag errors, central MLC errors and monitor unit errors) were intentionally introduced to modify the clinical plans through an in-house Matlab program. This resulted in 187 modified plans. The 2D %GP and 3D %GP were analyzed using different dose-difference and distance-toagreement (1%-1mm, 2%-2mm and 3%-3mm) and 20% dose threshold. The 2D %GP and 3D %GP were then compared not only for the whole region, but also for the PTVs and critical structures using the statistical Pearson’s correlation coefficient (γ). Results: For different delivery errors, the average comparison of 2D %GP and 3D %GP showed different conclusions. The statistical correlation coefficients between 2D %GP and 3D %GP for the whole dose distribution showed that except for 3%/3mm criterion, 2D %GP and 3D %GP of 1%/1mm criterion and 2%/2mm criterion had strong correlations (Pearson’s γ value >0.8). Compared with the whole region, the correlations of 2D %GP and 3D %GP for PTV were better (the γ value for 1%/1mm, 2%/2mm and 3%/3mm criterion was 0.959, 0.931 and 0.855, respectively). However for the rectum, there was no correlation between 2D %GP and 3D %GP. Conclusion: For prostate IMRT, the correlation between 2D %GP and 3D %GP for the PTV is better than that for normal structures. The lower dose-difference and DTA criterion shows less difference between 2D %GP and 3D %GP. Other factors such as the dosimeter characteristics and TPS algorithm bias may also influence the correlation between 2D %GP and 3D %GP.

60 APPLIED LIFE SCIENCES↗

Site Environmental Report for 2012 Sandia National Laboratories California

Sandia National Laboratories, California (SNL/CA) is a government-owned/contractor-operated laboratory. Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, manages and operates the laboratory for the Department of Energy’s National Nuclear Security Administration (NNSA). The NNSA Sandia Field Office administers the contract and oversees contractor operations at the site. This Site Environmental Report for 2012 was prepared in accordance with DOE Order 231.1B, Environment, Safety and Health Reporting (DOE 2011d). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2012. General site and environmental program information is also included.

54 ENVIRONMENTAL SCIENCES↗

Site environmental report for 2011. Sandia National Laboratories, California

Sandia National Laboratories, California (SNL/CA) is a government-owned/contractoroperated laboratory. Sandia Corporation, a wholly-owned subsidiary of Lockheed Martin Corporation, manages and operates the laboratory for the Department of Energy’s National Nuclear Security Administration (NNSA). The NNSA Sandia Site Office administers the contract and oversees contractor operations at the site. This Site Environmental Report for 2011 was prepared in accordance with DOE Order 231.1B, Environment, Safety and Health Reporting (DOE 2011d). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2011. General site and environmental program information is also included.

54 ENVIRONMENTAL SCIENCES↗

Summary Report for the Environmental Protection Agency MERL/FRMAC/RAP Mission Alignment Exercise held at the Savannah River Site on June 9-13 2014

From June 9th thru June 13th 2014, members of the Federal Radiological Monitoring and Assessment Center (FRMAC), the Environmental Protection Agency (EPA) and the Department of Energy Radiological Assistance Program (DOE RAP) Region-3 participated in a joint nuclear incident emergency response exercise at the Savannah River Site (SRS) near Aiken, South Carolina. The purpose of this exercise was to strengthen the interoperability relationship between the FRMAC, RAP, and the EPA Mobile Environmental Radiation Laboratory (MERL) stationed in Montgomery, Alabama. The exercise was designed to allowed members of the DOE RAP Region-3 team to collect soil, water, vegetation and air samples from SRS and submit them through an established FRMAC hotline. Once received and processed through the hotline, FRMAC delivered the samples to the EPA MERL for sample preparation and laboratory radiological analysis. Upon completion of laboratory analysis, data was reviewed and submitted back to FRMAC via an electronic data deliverable (EDD). As part of the exercise, an evaluation was conducted to identify gaps and potential improvements in each step of the processes. Additionally, noteworthy practices and potential future areas of interoperability between FRMAC and EPA were acknowledged. The exercise also provided a unique opportunity for FRMAC personnel to observe EPA sample receipt and sample preparation processes and to gain familiarity with the MERL laboratory instrumentation and radiation detection capabilities. The observations and lessons-learned from this exercise will be critical for developing a more efficient, integrated response for future interactions between the FRMAC and EPA assets.

54 ENVIRONMENTAL SCIENCES↗

Site Environmental Report for 2014 SNL/CA

Sandia National Laboratories, California (SNL/CA) is a government-owned/contractoroperated laboratory. Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, manages and operates the laboratory for the Department of Energy’s National Nuclear Security Administration (NNSA). The NNSA Sandia Field Office administers the contract and oversees contractor operations at the site. This Site Environmental Report for 2014 was prepared in accordance with DOE Order 231.1B, Environment, Safety and Health Reporting (DOE 2011d). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2014. General site and environmental program information is also included.

54 ENVIRONMENTAL SCIENCES↗

Numerical Simulation of Biogenic Fluid Catalytic Cracking (BFCC) Regenerators at Different Scales with MFIX-Exa

Catalytic Fast Pyrolysis (CFP) is a process that converts biomass into liquid intermediates suitable for transportation fuels by rapidly heating it in the presence of a catalyst, aiming to produce stable oils with reduced oxygen content. During CFP, the catalyst can become deactivated by the accumulation of coke, a carbon-rich deposit formed from the decomposition of biomass components. Unlike in petroleum refining, regenerating coked catalysts from biomass pyrolysis requires specific approaches due to the different chemical nature of the coke formed. An experimental technique, Temperature Programmed Oxidation (TPO), was used to study the de-coking process by gradually increasing temperature while monitoring the production of CO and CO2, which provides data for kinetic modeling. Utilizing data from TPO experiments, coke combustion kinetic model was developed to describe the rate of coke removal at different temperatures, allowing for simulation of regeneration processes. Then kinetic model is integrated into MFIX-Exa for the simulation of Biogenic Fluid Catalytic Cracker (BFCC) regenerator at different scales, enabling analysis of catalyst flow, temperature distribution, and regeneration efficiency under various operating conditions.

biogenic fluid catalytic cracking↗