Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Statistical Model Analysis of (n,p) Cross Sections and Average Energy For Fission Neutron Spectrum

Investigation of charged particle emission reaction cross sections for fast neutrons is important to both nuclear reactor technology and the understanding of nuclear reaction mechanisms. In particular, the study of (n,p) cross sections is necessary to estimate radiation damage due to hydrogen production, nuclear heating and transmutations in the structural materials of fission and fusion reactors. On the other hand, it is often necessary in practice to evaluate the neutron cross sections of the nuclides for which no experimental data are available.Because of this, we carried out the systematical analysis of known experimental (n,p) and (n,a) cross sections for fast neutrons and observed a systematical regularity in the wide energy interval of 6-20 MeV and for broad mass range of target nuclei. To explain this effect using the compound, pre-equilibrium and direct reaction mechanisms some formulae were deduced. In this paper, in the framework of the statistical model known experimental (n,p) cross sections averaged over the thermal fission neutron spectrum of U-235 are analyzed. It was shown that the experimental data are satisfactorily described by the statistical model. Also, in the case of (n,p) cross sections the effective average neutron energy for fission spectrum of U-235 was found to be around 3 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of a Thermo Scientific D711 D-T neutron generator located in a low-scatter facility

A dosimetry experiment used to measure the neutron flux and spectrum of a D-T neutron generator is presented. The D-T generator at Pacific Northwest National Laboratory is installed in the middle of a large room to minimize scatter of neutrons back to the sample. The efficacy of maintaining a pure fast neutron field for the sample is investigated. Twenty-one positions within 13 cm of the neutron source contained foils or wires of Fe, Ni, Al with additional Au, and In monitors at some locations. Spectral adjustment of the neutron flux at each position based on measured reaction rates and theoretical Monte Carlo calculations show that at least 99.1% of the spectrum lies above 110 keV for all measured positions, and neutrons above 14 MeV can account for as much as 91% at locations along the axis of the generator and close to the source. The 14 MeV component drops to 77% in radial positions far from the source. The largest total flux observed was 8.29E+08 n/cm2-s (±1.4%) in the center of the cooling cap, although additional experiments have shown this value could be as high as 1.20E+09 n/cm2-s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Perdeuteration, crystallization, data collection and comparison of five neutron diffraction data sets of complexes of human galectin-3C

Galectin-3 is an important protein in molecular signalling events involving carbohydrate recognition, and an understanding of the hydrogen-bonding patterns in the carbohydrate-binding site of its C-terminal domain (galectin-3C) is important for the development of new potent inhibitors. The authors are studying these patterns using neutron crystallography. Here, the production of perdeuterated human galectin-3C and successive improvement in crystal size by the development of a crystal-growth protocol involving feeding of the crystallization drops are described. The larger crystals resulted in improved data quality and reduced data-collection times. Furthermore, protocols for complete removal of the lactose that is necessary for the production of large crystals of apo galectin-3C suitable for neutron diffraction are described. Five data sets have been collected at three different neutron sources from galectin-3C crystals of various volumes. It was possible to merge two of these to generate an almost complete neutron data set for the galectin-3C–lactose complex. As a result, these data sets provide insights into the crystal volumes and data-collection times necessary for the same system at sources with different technologies and data-collection strategies, and these insights are applicable to other systems.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal scattering law for ice based on neutron time-of-flight experiments carried out at the SEQUOIA spectrometer at the Oak Ridge National Laboratory

Precise estimation of neutron thermalization in moderators relies on high-fidelity thermal scattering cross-section data governed by the thermal scattering law (TSL). The Institut de Radioprotection et de Sûreté Nucléaire (IRSN) has been working on the development of improved TSL for light water ice. Many polymorphic phases of light water ice exist depending on the thermodynamic conditions. The most common type of ice at standard pressure and temperature below water freezing point (273.15 K) is ice-Ih. It is essential to have high-resolution experimental double differential data for developing and/or validating TSL for moderator materials.Existing experimental double-differential scattering data for ice-Ih are extremely sparse and of limited quality. New high-quality double-differential measurements for ice-Ih over multiple temperatures and incident neutron energies would directly support the validation and improvement of ice-Ih TSL models for criticality safety applications.Series of time-of-flight (TOF) inelastic neutron scattering experiments on ice-Ih at temperatures starting at 271 K and down to 6 K, have been carried out at the SEQUOIA spectrometer at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), United States. The experiments have been performed for incident neutron energies, Ei= 11, 55, 160, 250, and 600 meV, to explore different excitation energies in the vibrational phonon spectrum. This paper presents the thermodynamic conditions and the details of the TOF measurements on ice-Ih and the derived phonon spectrum from the experimentally measured double differential data. A study of the variation of the phonon spectrum of ice-Ih as a function of temperature is highlighted, and a preliminary TSL evaluation is developed based on the experimental phonon spectrum.

Jaiswal, V↗

Diamond detector for high rate monitors of fast neutrons beams

A fast neutron detection system suitable for high rate measurements is presented. The detector is based on a commercial high purity single crystal diamond (SDD) coupled to a fast digital data acquisition system. The detector was tested at the ISIS pulsed spallation neutron source. The SDD event signal was digitized at 1 GHz to reconstruct the deposited energy (pulse amplitude) and neutron arrival time; the event time of flight (ToF) was obtained relative to the recorded proton beam signal t{sub 0}. Fast acquisition is needed since the peak count rate is very high ({approx}800 kHz) due to the pulsed structure of the neutron beam. Measurements at ISIS indicate that three characteristics regions exist in the biparametric spectrum: i) background gamma events of low pulse amplitudes; ii) low pulse amplitude neutron events in the energy range E{sub dep}= 1.5-7 MeV ascribed to neutron elastic scattering on {sup 12}C; iii) large pulse amplitude neutron events with E{sub n} < 7 MeV ascribed to {sup 12}C(n,{alpha}){sup 9}Be and 12C(n,n')3{alpha}.

43 PARTICLE ACCELERATORS↗

A Rietveld refinement method for angular- and wavelength-dispersive neutron time-of-flight powder diffraction data

This paper introduces a two-dimensional extension of the well established Rietveld refinement method for modeling neutron time-of-flight powder diffraction data. The novel approach takes into account the variation of two parameters, diffraction angle 2θ and wavelength λ, to optimally adapt to the varying resolution function in diffraction experiments. By doing so, the refinement against angular- and wavelength-dispersive data gets rid of common data-reduction steps and also avoids the loss of high-resolution information typically introduced by integration. In a case study using a numerically simulated diffraction pattern of Rh 0.81 Fe 3.19 N taking into account the layout of the future POWTEX instrument, the profile function as parameterized in 2θ and λ is extracted. As a proof-of-concept, the resulting instrument parameterization is then utilized to perform a typical refinement of the angular- and wavelength-dispersive diffraction pattern of CuNCN, yielding excellent residuals within feasible computational efforts. Another proof-of-concept is carried out by applying the same approach to a real neutron diffraction data set of CuNCN obtained from the POWGEN instrument at the Spallation Neutron Source in Oak Ridge. The paper highlights the general importance of the novel approach for data analysis at neutron time-of-flight diffractometers and its possible inclusion within existing Rietveld software packages.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PERFORMANCE OF THE SNS FRONT END AND WARM LINAC

The Spallation Neutron Source accelerator systems will deliver a 1.0 GeV, 1.4 MW proton beam to a liquid mercury target for neutron scattering research. The accelerator complex consists of an H{sup -} injector, capable of producing one-ms-long pulses at 60 Hz repetition rate with 38 mA peak current, a 1 GeV linear accelerator, an accumulator ring and associated transport lines. The 2.5 MeV beam from the Front End is accelerated to 87 MeV in the Drift Tube Linac, then to 186 MeV in a Coupled-Cavity Linac and finally to 1 GeV in the Superconducting Linac. With the completion of beam commissioning, the accelerator complex began operation in June 2006 and beam power is being gradually ramped up toward the design goal. Operational experience with the injector and linac will be presented including chopper performance, longitudinal beam dynamics study, and the results of a beam loss study.

Aleksandrov, Alexander V↗

Energy spectra, sources, and shielding considerations for neutrons generated by a flattening filter-free Clinac

Neutron production is an unwanted result of high-energy radiation therapy and results in secondary exposure of patients and radiation therapists to radiation. Recent studies have shown that delivering therapy using a standard medical accelerator with the flattening filter removed may reduce neutron fluence by nearly 70% over the course of prostate intensity-modulated radiation therapy (IMRT). In the current study, the {sup 197}Au Bonner sphere technique was used to compare the neutron spectrum produced when the filter is present and when it is absent. In addition, the following was calculated: (1) the neutron-shielding parameters of source strength and ambient dose equivalent (H{sub 0}) and (2) using the Monte Carlo technique, the sources of neutron production in the accelerator head. It was found that the neutron spectrum was nearly constant, regardless of the presence of the flattening filter; however, the total fluence and ambient dose equivalent over the course of prostate IMRT were more than 70% lower when the filter was removed. Similarly, shielding parameters were lower when the filter was removed. Finally, the primary collimator and jaws accounted for the majority of neutron production, both with and without the flattening filter; however, with the flattening filter removed, the upper jaw accounted for much more neutron production relative to when the filter was present. Ultimately, removal of the flattening filter may offer several clinical advantages, including a reduction in the dose from neutrons to the patient and to radiation personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron Imaging Control Report: FY 2016

During the 2016 fiscal year, work began on the supervision and control systems for the neutron source currently under construction in the B194 accelerator caves. This source relies on a deuteron beam colliding with a high-speed stream of deuterium gas to create neutrons, which poses significant technical challenges. To help overcome those challenges, an integrated, operator-focused control architecture is required to collect and assimilate disparate data from a variety of measurement points, as well as provide the means to remotely control the system hardware.

43 PARTICLE ACCELERATORS↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Ground-Based Testing of TiB2 and Al2O3/TiB2 Response to Space Environment

Two materials, titanium diboride and an alumina/titanium diboride composite, exhibit characteristics favorable for use in multiple space applications. These characteristics include low mass (4.52 gm/cc), high strain rate impact resistance, high temperature use (3000oC M.P.), thermal and electrical conductivity, thermal shock resistance, and high visible-range reflectivity. Additionally, the presence of boron in these materials gives them the potential to shield against neutron radiation as well as charged radiation. These materials are flying on MISSE 6 to assess material changes resulting from exposure to the space environment. This study provides a preliminary, ground-based examination of these materials' interactions with individual components of the space environment, in particular atomic oxygen (AO) and neutron radiation, in order to better predict and understand post-flight results. Individual specimens are exposed to ground state AO and surface oxidation is measured. Equivalent exposures of up to 13 months show no rapid oxidation, however evidence indicates some surface oxidation occurring. Other samples are placed near a polyethylene moderated, one Ci Am/Be neutron source to determine their shielding capability. Comparisons between exposed and shielded indium foil, which is activated by transmitted neutrons, measure each material's ability to shield neutrons. Preliminary results indicate a significant shielding benefit provided by both materials.

Jefferies, Sharon A.↗

Modeling Radiation Sources for Experimental Validation

To build on previously completed experimental work, I have been working to implement a model of our lab’s Americium-Beryllium neutron source and Ludlum detection instruments computationally to provide secondary verification of our experimental results. This has been done using the radiation transport code MCNP6 (Monte Carlo N-Particle). I have developed files to calculate the mass ratio of various composite materials that we have exposed to the radiation source, as well as the components of the detection instruments and converted all of these into geometric coordinates that define the experimental setup. Identifying the proper energy distribution and detector efficiencies as well as the correct interpretation of the detector physics have proven to be the most difficult and time-consuming challenges of the work. It is currently too early for results based on the most updated and accurate models. With this experience, the next step is to develop another source model of a proton beam to simulate exposures on other composite targets. This will be developed based on existing experimental datasets, but not used to validate them. Each of these projects will further define the radiation shielding needs for humans in space radiation environments that astronauts will someday be exposed to beyond Low Earth Orbit.

Juliana Simon↗

Analyses to support waste disposition of SNS Inner Reflector Plug

The Spallation Neutron Source Inner Reflector Plug (IRP) is scheduled for replacement. It reached end of life-time because of moderator neutron poison and decoupler burn-out, which is used for shaping neutron pulses. The replacement of IRP is a complex task due to its location in the area receiving high irradiation, being under significant amount of shielding, and size, which requires removal in segments. In order to support the disposal of spent IRP, waste characterization analyses are performed. These analyses include an accurate estimate of the radionuclide inventory and the residual dose rate. Using this data, the package class is determined for the and appropriate containers for temporary storage and subsequent transport are assigned. Analyses are performed in four steps: a radiation transport analysis of the radiation environment for producing the flux and isotope production information using MCNPX, a multi-cell transmutation analysis based n CINDER90, the generation of decay gamma source terms, and the gamma transport analyses of the decay gammas arriving at residual dose rates again using MCNPX. . Due to the complexity of the geometry of the lower segment, transport analyses for the residual dose rate require elaborate work for the source terms definition.

Popova, Irina I.↗

Methods for lipid nanostructure investigation at neutron and synchrotron sources

A lipid membrane is a main component of biological membranes. Contemporary bionanotechnologies use phospholipids and ceramides as basic components of drugs and cosmetic preparations. Phospholipids-based nanoparticles are used as drug carriers. Effective development of bionanotechnologies in Russia calls for creation of physical methods to diagnose the particle nanostructure which would be promising for application in pharmacology. Radiation with wavelengths of 1–10 Å is an adequate instrument for detecting the nanostructure of lipid bi- and monolayers. The review deals with methods that apply neutron scattering and synchrotron radiation for studying nanostructures of lipid membranes, phospholipid nanoparticles, and phospholipid monolayers on a water surface by techniques of diffraction, small-angle scattering, and reflectometry. The importance of the mutually complementary application of neutron and synchrotron radiation for solving urgent problems of membrane biophysics, microbiology, dermapharmacology, and bionanotechnologies is demonstrated by particular examples of studies of phospholipid membranes and ceramide-based membranes. The efficiency of development and application of new methods for solving urgent problems of biophysics is shown. The review is written on the basis of results obtained over the period of 1999–2010 at the Joint Institute for Nuclear Research (JINR) Laboratory of Neutron Physics in collaboration with the Pharmaceutical Departments of universities of France (Paris-Sud, Chatenay Malabry) and Germany (Martin Luther University, Halle). The experiments were performed at various European and Russian neutron and synchrotron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision Measurement of the 16 O($n, n'γ$) Cross Section using $γ$-ray Detection in Liquid Scintillators with H 2 O and BeO Targets

The 16 O($n, n'γ$) reaction was measured at the Los Alamos Neutron Science Center white neutron source using γ-ray detection in liquid scintillators present in the upper hemisphere of the Correlated Gamma-Neutron Array for sCattering (CoGNAC). Separate measurements of this reaction were performed using H 2 O and BeO targets in successive years. The unique high energies of γ rays emitted from the 16 O($n, n'γ$) reaction facilitated a clean selection of this reaction from threshold to 9.8 MeV incident neutron energy without the need for precise measurements of the γ-ray energy or the scattered neutrons. The precise time resolution of the liquid scintillator detectors was then exploited to obtain high-resolution incident neutron energy measurements, and good agreement was obtained between the H 2 O and BeO results reported here. The dominant literature data sets for this reaction have systematic differences between them, but the present results improve upon the neutron energy resolution of earlier measurements and show important discrepancies in recent data. Finally, tentative data are also shown up to 20 MeV incident neutron energy but are potentially subject to improved understanding of the relative γ-ray and α decay branches from 16 O excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new method to measure the U-235 content in fresh LWR fuel assemblies via fast-neutron passive self-interrogation

The purpose of this paper is to provide a solution to a decades old safeguards problem in the verification of the fissile concentration in fresh light water reactor (LWR) fuel assemblies. The problem is that the burnable poison (e.g. Gd 2 O 3 ) addition to the fuel rods decreases the active neutron assay for the fuel assemblies. This paper presents a new innovative method for the verification of the 235 U linear mass density in fresh LEU fuel assemblies that is insensitive to the burnable poison content. The technique makes use of the 238 U atoms in the fuel rods to self-interrogate the 235 U mass. The innovation for the new approach is that the 238 U spontaneous fission (SF) neutrons from the rods induces fission reactions (IF) in the 235 U that are time correlated with the SF source neutrons. Thus, the coincidence gate counting rate benefits from both the nu-bar of the 238 U SF (2.07) and the 235 U IF (2.44) for a fraction of the IF reactions. Whereas, the 238 U SF background has no time-correlation boost. The higher the detection efficiency, the higher the correlated boost because background neutron counts from the SF are being converted to signal doubles. This time-correlation in the IF signal increases signal/background ratio that provides a good precision for the net signal from the 235 U mass. The hard neutron energy spectrum makes the technique insensitive to the burnable poison loading where a Cd or Gd liner on the detector walls is used to prevent thermal-neutron reflection back into the fuel assembly from the detector. Here, we have named the system the fast-neutron passive collar (FNPC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility study to use neutron capture for an ultralow energy nuclear-recoil calibration in liquid xenon

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. Further, the measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted γ cascades can provide the nuclei with up to 0.3 keV nr of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below this energy will contribute to a greater sensitivity for liquid xenon experiments in searches for light WIMPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of the Universal Neutron Irradiator

SHINE medical isotopes is developing a novel method to produce the medical isotope Mo-99, which is the parent of Tc-99m, the most widely used diagnostic compound in nuclear medicine. This method utilizes U-235 fission in a subcritical liquid target solution, driven by an accelerator-based neutron source that is based on a deuterium-tritium reaction in a gaseous target. In this approach, the neutron-generating target is surrounded by uranyl sulfate (low-enriched uranium); fission in the uranium salt solution efficiently produces the desired Mo-99, as well as other fission products. After irradiation, Mo-99 is separated and the uranyl sulfate solution can be irradiated again to produce Mo-99. This allows the solution to be recycled for a very long time and significantly reduces the amount of associated nuclear waste. SHINE has received U.S. Nuclear Regulatory Commission (NRC) approval to construct an Mo-99 production facility based on this method. In order to produce Mo-99 efficiently, the solution should be as close as possible to criticality. Because the solution is over moderated, any precipitation could push the solution to become critical and thereby hard to control. One of the possible precipitation scenarios is the formation of uranyl peroxide. Under irradiation, water decomposes into the products of radiolysis, some of which will form peroxide. To prevent precipitation, one has to develop a way to decompose the peroxide before it can react with uranium and form hard-to-dissolve precipitates. To study peroxide formation and develop methods to prevent precipitation, we are developing an experiment capable of mimicking radiation conditions in the SHINE system. This report describes the irradiation setup we designed to irradiate a small volume of uranyl sulfate solution for the duration of one SHINE irradiation (~6 days) at the relevant fission power (~0.5 W/cc)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗