Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

An Integrated Support and Alignment System for Large ILC Lattice Elements

The manipulators used to support and position lattice elements are critical components of all particle accelerators. The increased use of large superconducting magnets and accelerator modules places even greater demands on these manipulators. However, the performance of these support systems has not kept pace with the advances made in other areas of accelerator technology. This results in accelerators that are difficult to align and may not be capable of achieving target luminosities. An innovative new type of positioning mechanism tailored to the requirements of the International Linear Collider is proposed. The Tri-Sphere System provides secure support for large lattice elements and precision adjustment in six degrees of freedom. Integrated target sockets allow the support system to be rapidly pre-aligned. The system's kinematic design passively guides lattice elements into their correct location during installation. A complimentary Portable Actuation Unit provides the advantages of automated adjustment and allows these adjustments to be completely decoupled from surveying.

43 PARTICLE ACCELERATORS↗

Southwestern Power Administration Combined Financial Statements, 2006-2009

We have audited the accompanying combined balance sheets of the Southwestern Federal Power System (SWFPS), as of September 30, 2009, 2008, 2007, and 2006, and the related combined statements of revenues and expenses, changes in capitalization, and cash flows for the years then ended. As described in note 1(a), the combined financial statement presentation includes the hydroelectric generation functions of another Federal agency (hereinafter referred to as the generating agency), for which Southwestern Power Administration (Southwestern) markets and transmits power. These combined financial statements are the responsibility of the management of Southwestern and the generating agency. Our responsibility is to express an opinion on these combined financial statements based on our audits. We conducted our audits in accordance with auditing standards generally accepted in the United States of America. Those standards require that we plan and perform the audits to obtain reasonable assurance about whether the combined financial statements are free of material misstatement. An audit includes consideration of internal control over financial reporting as a basis for designing audit procedures that are appropriate in the circumstances, but not for the purpose of expressing an opinion on the effectiveness of Southwestern and the generating agency’s internal control over financial reporting. Accordingly, we express no such opinion. An audit also includes examining, on a test basis, evidence supporting the amounts and disclosures in the combined financial statements, assessing the accounting principles used and significant estimates made by management, as well as evaluating the overall combined financial statement presentation. We believe that our audits provide a reasonable basis for our opinion. In our opinion, the combined financial statements referred to above present fairly, in all material respects, the respective financial position of the Southwestern Federal Power System, as of September 30, 2009, 2008, 2007, and 2006, and the results of its operations and its cash flow for the years then ended, in conformity with U.S. generally accepted accounting principles. Our audits were conducted for the purpose of forming an opinion on the 2009, 2008, 2007, and 2006 SWFPS’s combined financial statements taken as a whole. The supplementary information in the combining financial statements is presented for purposes of additional analysis and is not a required part of the basic combined financial statements. The supplementary information has been subjected to the auditing procedures applied in the audit of the basic combined financial statements and, in our opinion, is fairly stated in all material respects in relation to the basic combined financial statements taken as a whole.

Financial statements, finance, 2009, 2008, 2007, 2↗

Actively controlled vibration welding system and method

A vibration welding system includes a controller, welding horn, an active material element, and anvil assembly. The assembly may include an anvil body connected to a back plate and support member. The element, e.g., a piezoelectric stack or shape memory alloy, is positioned with respect to the assembly. The horn vibrates in a desirable first direction to form a weld on a work piece. The element controls any vibrations in a second direction by applying calibrated response to the anvil body in the second direction. A method for controlling undesirable vibrations in the system includes positioning the element with respect to the anvil assembly, connecting the anvil body to the support member through the back plate, vibrating the horn in a desirable first direction, and transmitting an input signal to the element to control vibration in an undesirable second direction.

42 ENGINEERING↗

Balanced truncation-rational Krylov methods for model reduction in large scale dynamical systems

In this paper, we consider the balanced truncation method for model reductions in large-scale linear and time-independent dynamical systems with multi-inputs and multi-outputs. The method is based on the solutions of two large coupled Lyapunov matrix equations when the system is stable or on the computation of stabilizing positive and semi-definite solutions of some continuous-time algebraic Riccati equations when the dynamical system is not stable. Using the rational block Arnoldi, we show how to compute approximate solutions to these large Lyapunov or algebraic Riccati equations. The obtained approximate solutions are given in a factored form and used to build the reduced order model. We give some theoretical results and present numerical examples with some benchmark models.

97 MATHEMATICS AND COMPUTING↗

Using kV-kV and CBCT imaging to evaluate rectal cancer patient position when treated prone on a newly available belly board

The goal of this work was to use daily kV-kV imaging and weekly cone-beam CT (CBCT) to evaluate rectal cancer patient position when treated on a new couch top belly board (BB). Quality assurance (QA) of the imaging system was conducted weekly to ensure proper performance. The positional uncertainty of the combined kV-kV image match and subsequent couch move was found to be no more than {+-} 1.0 mm. The average (1 SD) CBCT QA phantom match was anterior-posterior (AP) = -0.8 {+-} 0.2 mm, superior-inferior (SI) = 0.9 {+-} 0.2 mm, and left-right (LR) = -0.1 {+-} 0.1 mm. For treatment, a set of orthogonal kV-kV images were taken and a bony anatomy match performed online. Moves were made along each axis (AP, SI, and LR) and recorded for analysis. CBCT data were acquired once every 5 fractions for a total of 5 images per patient. The images were all taken after the couch move but before treatment. A 3-dimensional (3D-3D) bony anatomy auto-match was performed offline and the residual difference in position recorded for analysis. The average ({+-} 1 SD) move required from skin marks, calculated over all 375 fractions (15 patients Multiplication-Sign 25 fractions/patient), were AP = -2.6 {+-} 3.7 mm, SI = -0.3 {+-} 4.9 mm, and LR = 1.8 {+-} 4.5 mm. The average residual difference in patient position calculated from the weekly CBCT data (75 total) were AP = -1.7 {+-} 0.4 mm, SI = 1.1 {+-} 0.6 mm, and LR = -0.5 {+-} 0.2 mm. These results show that the BB does provide simple patient positioning that is accurate to within {+-} 2.0 mm when using online orthogonal kV-kV image matching of the pelvic bony anatomy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Passivity analysis for a winged re-entry vehicle

Application of simple adaptive control (SAC) theory to the design of guidance and control systems for winged re-entry vehicles has been proven successful. To apply SAC to these non-linear and non-stationary systems, it needs to be Almost Strictly Passive (ASP), which is an extension of the Almost Strictly Positive Real (ASPR) condition for linear, time-invariant systems. To fulfill the ASP condition, the controlled, non-linear system has to be minimum-phase (i.e., the zero dynamics is stable), and there is a specific condition for the product of output and input matrix. Earlier studies indicate that even the linearised system is not ASPR. The two problems at hand are: 1) the system is non-minimum phase when flying with zero bank angle, and 2) whenever there is hybrid control, e.g., yaw control is established by combined reaction and aerodynamic control for the major part of flight, the second ASPR condition cannot be met. In this paper we look at both issues, the former related to the guidance system and the latter to the attitude-control system. It is concluded that whenever the nominal bank angle is zero, the passivity conditions can never be met, and guidance should be based on nominal commands and a redefinition of those whenever the error becomes too large. For the remaining part of the trajectory, the passivity conditions are marginally met, but it is proposed to add feedforward compensators to alleviate these conditions. The issue of hybrid control is avoided by redefining the controls with total control moments and adding a so-called control allocator. Deriving the passivity conditions for rotational motion, and evaluating these conditions along the trajectory shows that the (non-linear) winged entry vehicle is ASP. The sufficient conditions to apply SAC for attitude control are thus met.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Benchmarking operational efficiency in waste collection: Discussion of current approaches and possible alternatives

Efficiency assessment and benchmarking are crucial for managing any organization. However, especially from a regulatory perspective, such efficiency assessment and benchmarking must be unbiased from context-specific issues and should provide an absolute rating, rather than a relative one. The current work reviews the approaches used for performance assessment and benchmarking waste collection services, revealing that the majority are biased and are not absolute, and proposes two alternative context-unbiased and absolute performance indicators, the collection capacity use (CCU) and the segregated waste collection efficiency (SWE). The proposed indicators were calculated for 246 utilities operating in Portugal. The utilities were then ranked accordingly, and their position was compared with the position attained using the equivalent performance indicators in the system currently in use by the Portuguese service regulator. The results reveal ranking differences of over 50 positions and illustrate how misleading the results from context-biased and relative metrics can be.

Sousa, V.↗

First evaluation of the feasibility of MLC tracking using ultrasound motion estimation

Purpose: To quantify the performance of the Clarity ultrasound (US) imaging system (Elekta AB, Stockholm, Sweden) for real-time dynamic multileaf collimator (MLC) tracking. Methods: The Clarity calibration and quality assurance phantom was mounted on a motion platform moving with a periodic sine wave trajectory. The detected position of a 30 mm hypoechogenic sphere within the phantom was continuously reported via Clarity’s real-time streaming interface to an in-house tracking and delivery software and subsequently used to adapt the MLC aperture. A portal imager measured MV treatment field/MLC apertures and motion platform positions throughout each experiment to independently quantify system latency and geometric error. Based on the measured range of latency values, a prostate stereotactic body radiation therapy (SBRT) delivery was performed with three realistic motion trajectories. The dosimetric impact of system latency on MLC tracking was directly measured using a 3D dosimeter mounted on the motion platform. Results: For 2D US imaging, the overall system latency, including all delay times from the imaging and delivery chain, ranged from 392 to 424 ms depending on the lateral sector size. For 3D US imaging, the latency ranged from 566 to 1031 ms depending on the elevational sweep. The latency-corrected geometric root-mean squared error was below 0.75 mm (2D US) and below 1.75 mm (3D US). For the prostate SBRT delivery, the impact of a range of system latencies (400–1000 ms) on the MLC tracking performance was minimal in terms of gamma failure rate. Conclusions: Real-time MLC tracking based on a noninvasive US input is technologically feasible. Current system latencies are higher than those for x-ray imaging systems, but US can provide full volumetric image data and the impact of system latency was measured to be small for a prostate SBRT case when using a US-like motion input.

60 APPLIED LIFE SCIENCES↗

Actively triggered 4d cone-beam CT acquisition

Purpose: 4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this “after-the-fact” binning approach, however, projections are unevenly distributed over respiratory phases resulting in inefficient utilization of imaging dose. To avoid excess dose in certain respiratory phases, and poor image quality due to a lack of projections in others, the authors have developed a novel 4d CBCT acquisition framework which actively triggers 2d projections based on the forward-predicted position of the tumor.Methods: The forward-prediction of the tumor position was independently established using either (i) an electromagnetic (EM) tracking system based on implanted EM-transponders which act as a surrogate for the tumor position, or (ii) an external motion sensor measuring the chest-wall displacement and correlating this external motion to the phase-shifted diaphragm motion derived from the acquired images. In order to avoid EM-induced artifacts in the imaging detector, the authors devised a simple but effective “Faraday” shielding cage. The authors demonstrated the feasibility of their acquisition strategy by scanning an anthropomorphic lung phantom moving on 1d or 2d sinusoidal trajectories.Results: With both tumor position devices, the authors were able to acquire 4d CBCTs free of motion blurring. For scans based on the EM tracking system, reconstruction artifacts stemming from the presence of the EM-array and the EM-transponders were greatly reduced using newly developed correction algorithms. By tuning the imaging frequency independently for each respiratory phase prior to acquisition, it was possible to harmonize the number of projections over respiratory phases. Depending on the breathing period (3.5 or 5 s) and the gantry rotation time (4 or 5 min), between ∼90 and 145 projections were acquired per respiratory phase resulting in a dose of ∼1.7–2.6 mGy per respiratory phase. Further dose savings and decreases in the scanning time are possible by acquiring only a subset of all respiratory phases, for example, peak-exhale and peak-inhale only scans.Conclusions: This study is the first experimental demonstration of a new 4d CBCT acquisition paradigm in which imaging dose is efficiently utilized by actively triggering only those projections that are desired for the reconstruction process.

61 RADIATION PROTECTION AND DOSIMETRY↗

Surface temperature comparison of the Arctic winter MOSAiC observations, ERA5 reanalysis, and MODIS satellite retrieval

Atmospheric model systems, such as those used for weather forecast and reanalysis production, often have significant and systematic errors in their representation of the Arctic surface energy budget and its components. The newly available observation data of the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition (2019/2020) enable a range of model analyses and validation in order to advance our understanding of potential model deficiencies. In the present study, we analyze deficiencies in the surface radiative energy budget over Arctic sea ice in the ERA5 global atmospheric reanalysis by comparing against the winter MOSAiC campaign data, as well as, a pan-Arctic level-2 MODIS ice surface temperature remote sensing product. We find that ERA5 can simulate the timing of radiatively clear periods, though it is not able to distinguish the two observed radiative Arctic winter states, radiatively clear and opaquely cloudy, in the distribution of the net surface radiative budget. The ERA5 surface temperature over Arctic sea ice has a conditional error with a positive bias in radiatively clear conditions and a negative bias in opaquely cloudy conditions. The mean surface temperature error is 4°C for radiatively clear situations at MOSAiC and up to 15°C in some parts of the Arctic. The spatial variability of the surface temperature, given by 4 observation sites at MOSAiC, is not captured by ERA5 due to its spatial resolution but represented in the level-2 satellite product. The sensitivity analysis of possible error sources, using satellite products of snow depth and sea ice thickness, shows that the positive surface temperature errors during radiatively clear events are, to a large extent, caused by insufficient sea ice thickness and snow depth representation in the reanalysis system. A positive bias characterizes regions with ice thickness greater than 1.5 m, while the negative bias for thinner ice is partly compensated by the effect of snow.

54 ENVIRONMENTAL SCIENCES↗

Laser Doppler sensor employing a single fan-shaped interference fringe system for distance and shape measurement of laterally moving objects

For monitoring the position and shape of fast moving and, especially, rotating objects such as turbo machine rotors, contactless and compact sensors with a high measurement rate as well as high precision are required. We present for the first time, to the best of our knowledge, a novel laser Doppler sensor employing a single fan-shaped interference fringe system, which allows measuring for the position and shape of fast moving solid bodies with known tangential velocity. It is shown theoretically as well as experimentally that this sensor offers concurrently high position resolution and high temporal resolution in contrast to conventional measurement techniques, since its measurement uncertainty is, in principle, independent of the object velocity. Moreover, it can be built very compact, because it features low complexity. To prove its operational capability and its potential for practical applications, radial and axial shape measurements of rotating bodies are demonstrated in comparison with triangulation. An average position resolution of about 2 {mu}m could be achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interlaced linear-nonlinear wave propagation in a warm multicomponent plasma

Linear and nonlinear propagations of arbitrary amplitude nonlinear structures, viz. solitons, double layers, and supersolitons are investigated in multicomponent plasma consisting of warm ions, two temperature nonthermal electrons and hot nonthermal positrons. The Sagdeev pseudopotential approach is employed to obtain the energy integral equation in such a multicomponent plasma using fluid theory. The effects of several plasma parameters on the ion acoustic solitons, double layers, and supersolitons are analyzed. It is found that the present system supports the coexistence of arbitrary amplitude positive and negative potential solitons in a certain region of parameter space in addition to compressive and rarefactive double layers. Furthermore, numerical calculations reveal that these structures may exist either in supersonic or subsonic regimes. Also, the present plasma system supports supersolitonic structure in supersonic regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WE-G-204-01: BEST IN PHYSICS (IMAGING): Effect of Image Processing Parameters On Nodule Detectability in Chest Radiography

Purpose: To investigate the effect of varying system image processing parameters on lung nodule detectability in digital radiography. Methods: An anthropomorphic chest phantom was imaged in the posterior-anterior position using a GE Discovery XR656 digital radiography system. To simulate lung nodules, a polystyrene board with 6.35mm diameter PMMA spheres was placed adjacent to the phantom (into the x-ray path). Due to magnification, the projected simulated nodules had a diameter in the radiographs of approximately 7.5 mm. The images were processed using one of GE’s default chest settings (Factory3) and reprocessed by varying the “Edge” and “Tissue Contrast” processing parameters, which were the two user-configurable parameters for a single edge and contrast enhancement algorithm. For each parameter setting, the nodule signals were calculated by subtracting the chest-only image from the image with simulated nodules. Twenty nodule signals were averaged, Gaussian filtered, and radially averaged in order to generate an approximately noiseless signal. For each processing parameter setting, this noise-free signal and 180 background samples from across the lung were used to estimate ideal observer performance in a signal-known-exactly detection task. Performance was estimated using a channelized Hotelling observer with 10 Laguerre-Gauss channel functions. Results: The “Edge” and “Tissue Contrast” parameters each had an effect on the detectability as calculated by the model observer. The CHO-estimated signal detectability ranged from 2.36 to 2.93 and was highest for “Edge” = 4 and “Tissue Contrast” = −0.15. In general, detectability tended to decrease as “Edge” was increased and as “Tissue Contrast” was increased. A human observer study should be performed to validate the relation to human detection performance. Conclusion: Image processing parameters can affect lung nodule detection performance in radiography. While validation with a human observer study is needed, model observer detectability for common tasks could provide a means for optimizing image processing parameters.

60 APPLIED LIFE SCIENCES↗

Interaction Junk: User Interaction-Based Evaluation of Visual Analytic Systems

With the growing need for visualization to aid users in understanding large, complex datasets, the ability for users to interact and explore these datasets is critical. As visual analytic systems have advanced to leverage powerful computational models and data analytics capabilities, the modes by which users engage and interact with the information are limited. Often, users are taxed with directly manipulating parameters of these models through traditional GUIs (e.g., using sliders to directly manipulate the value of a parameter). However, the purpose of user interaction in visual analytic systems is to enable visual data exploration – where users can focus on their task, as opposed to the tool or system. As a result, users can engage freely in data exploration and decision-making, for the purpose of gaining insight. In this position paper, we discuss how evaluating visual analytic systems can be approached through user interaction analysis, where the goal is to minimize the cognitive translation between the visual metaphor and the mode of interaction (i.e., reducing the “Interactionjunk”). We motivate this concept through a discussion of traditional GUIs used in visual analytics for direct manipulation of model parameters, and the importance of designing interactions the support visual data exploration.

evaluation↗

Perturbation theory for the logarithm of a positive operator

In various contexts in mathematical physics, such as out-of-equilibrium physics and the asymptotic information theory of many-body quantum systems, one needs to compute the logarithm of a positive unbounded operator. Examples include the von Neumann entropy of a density matrix and the flow of operators with the modular Hamiltonian in the Tomita-Takesaki theory. Often, one encounters the situation where the operator under consideration, which we denote by ∆, can be related by a perturbative series to another operator ∆ 0 , whose logarithm is known. We set up a perturbation theory for the logarithm log ∆. It turns out that the terms in the series possess a remarkable algebraic structure, which enables us to write them in the form of nested commutators plus some “contact terms”.

97 MATHEMATICS AND COMPUTING↗

SU-F-J-20: Commissioning and Acceptance Testing of the C-Rad CatalystHD Surface Imaging System

Introduction: With the increasing use of surface-based, nonionizing image-guided radiotherapy (IGRT) systems, a comprehensive set of clinical acceptance and commissioning procedures are needed to ensure correct functionality and proper clinical integration. Although TG-147 provides a specific set of parameters, measurement methodologies have yet to be described. The aim of this study was to provide a comprehensive overview of the commissioning and acceptance analysis performed for the C-Rad CatalystHD imaging system. Methods and Materials: Methodology for the commissioning and acceptance of the C-Rad CatalystHD imaging system was developed using commercially available clinical equipment. Following TG-147 guidelines, the following tests were performed: integration of peripheral equipment, system drift, static spatial reproducibility and localization accuracy, static end-to-end analysis, static rotational accuracy, dynamic spatial accuracy, dynamic temporal accuracy, dynamic radiation delivery and a comprehensive end-to-end analysis. Results: The field of view (FOV) of the CatalystHD was 105×109×83 cm3 in the lateral, longitudinal and vertical directions. For thermal equilibrium and system drift, a thermal drift of 1.0mm was noted. A 45 min warmup time is recommended if the system has been shut off an extended period of time (>24 hours) before the QA procedure to eliminate any thermal drift. Spatial reproducibility was found to be 0.05±0.03 mm using a rigid phantom. For the static localization accuracy, system agreement with couch shifts was within 0.1±0.1 mm and positioning agreement with kV-CBCT was 0.16±0.10 mm. For static rotational accuracy, system agreement with a high precision rotational stage (0.01 deg precision) was within 0.10±0.07 deg. Dynamic spatial and temporal localization accuracy was found to be within 0.2±0.1 mm. Conclusion: A comprehensive commissioning and acceptance study was performed using commercially available phantoms and in-house methodologies to provide a performance evaluation of the CatalystHD imaging system.

60 APPLIED LIFE SCIENCES↗

Miniaturized hand held microwave interference scanning system for NDE of dielectric armor and armor systems

Inspection of ceramic-based armor has advanced through development of a microwave-based, portable, non-contact NDE system. Recently, this system was miniaturized and made wireless for maximum utility in field applications. The electronic components and functionality of the laboratory system are retained, with alternative means of position input for creation of scan images. Validation of the detection capability was recently demonstrated using specially fabricated surrogates and ballistic impact-damaged specimens. The microwave data results have been compared to data from laboratory-based microwave interferometry systems and digital x-ray imaging. The microwave interference scanning has been shown to reliably detect cracks, laminar features and material property variations. The authors present details of the system operation, descriptions of the test samples used and recent results obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preheating of fluid in a supercritical Brayton cycle power generation system at cold startup

Various technologies pertaining to causing fluid in a supercritical Brayton cycle power generation system to flow in a desired direction at cold startup of the system are described herein. A sensor is positioned at an inlet of a turbine, wherein the sensor is configured to output sensed temperatures of fluid at the inlet of the turbine. If the sensed temperature surpasses a predefined threshold, at least one operating parameter of the power generation system is altered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗