Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Probing the anisotropies of a stochastic gravitational-wave background using a network of ground-based laser interferometers

We present a maximum-likelihood analysis for estimating the angular distribution of power in an anisotropic stochastic gravitational-wave background using ground-based laser interferometers. The standard isotropic and gravitational-wave radiometer searches (optimal for point sources) are recovered as special limiting cases. The angular distribution can be decomposed with respect to any set of basis functions on the sky, and the single-baseline, cross-correlation analysis is easily extended to a network of three or more detectors--that is, to multiple baselines. A spherical-harmonic decomposition, which provides maximum-likelihood estimates of the multipole moments of the gravitational-wave sky, is described in detail. We also discuss (i) the covariance matrix of the estimators and its relationship to the detector response of a network of interferometers, (ii) a singular-value decomposition method for regularizing the deconvolution of the detector response from the measured sky map, (iii) the expected increase in sensitivity obtained by including multiple baselines, and (iv) the numerical results of this method when applied to simulated data consisting of both pointlike and diffuse sources. Comparisons between this general method and the standard isotropic and radiometer searches are given throughout, to make contact with the existing literature on stochastic background searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parts Per Million CH4 Chemoresistor Sensors Based on multi wall Carbon Nanotubes/Metal-oxide Nanoparticles

This paper presents a novel atomic layer deposition (ALD) based ZnO functionalization of surface pretreated multiwalled carbon nanotubes (MWCNTs) for highly sensitive methane chemoresistive sensors. The temperature optimization of the ALD process leads to enhanced ZnO nanoparticle functionalization and improvement in their crystalline quality as shown by transmission electron microscopy. Here we propose a facile and effective top-down method for the high-yield fabrication of chemoresistor sensors making use of MWCNTs/ZnO composite. The behavior of MWCNTs/ZnO sensors in presence of methane concentrations down to 10 ppm level has been investigated. The sensor is currently being tested under a range of conditions that include potentially interfering gases and changes to relative humidity.

chemoresistor, carbon nanotubes, metal-oxide- nano↗

Retina Lesion and Microaneurysm Segmentation using Morphological Reconstruction Methods with Ground-Truth Data

In this work we report on a method for lesion segmentation based on the morphological reconstruction methods of Sbeh et. al. We adapt the method to include segmentation of dark lesions with a given vasculature segmentation. The segmentation is performed at a variety of scales determined using ground-truth data. Since the method tends to over-segment imagery, ground-truth data was used to create post-processing filters to separate nuisance blobs from true lesions. A sensitivity and specificity of 90% of classification of blobs into nuisance and actual lesion was achieved on two data sets of 86 images and 1296 images.

60 APPLIED LIFE SCIENCES↗

Design of BLDC Motor Diagnostic Device Based on Surge Test for Phase to Ground Fault

BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.

BLDC motor↗

Transparent Humidity Sensor Using Cross-Linked Polyelectrolyte Membrane

This paper describes the fabrication of a porous cross-linked polyelectrolyte membrane and the characterization of its humidity sensitivity performance. Electrostatic self-assembly, combined with acid treatment, and post-deposition annealing produced the membrane. The fabrication process offers the ability to control the thickness of the membrane, as well as enabling the engineering of the humidity sensitivity properties. A transparent humidity sensor was fabricated by integrating the membrane between two parallel electrodes. In order to improve the moisture absorption and diffusion, both the polyelectrolyte layer and the electrode were made porous. The membrane was cross-linked to enhance the durability in high humid environments. Such a polyelectrolyte membrane showed high sensitivity to relative humidity variation over a range of 25%–99%. The see-through property of the structure adds extra features and benefits to the sensor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monolingual but not bilingual infants demonstrate racial bias in social cue use

Abstract Bilingualism exerts early and pervasive effects on cognition, observable in infancy. Thus far, investigations of infant bilingual cognition have focused on sensitivity to visual memory, executive function, and linguistic sensitivity. Much less research has focused on how bilingualism impacts processing of social cues. The present study sought to investigate whether bilingualism modulates the expression of one aspect of social processing: early racial bias. Using a gaze‐following paradigm, we investigated whether 18‐ to 20‐month‐old monolingual and bilingual infants favored their own race. Results demonstrated that monolingual infants favored their own race in following a model whose direction of gaze signaled an event. In contrast, bilingual infants demonstrated race‐neutral gaze‐following patterns, relying more heavily on the reliability of the behavior of the model over race. Findings suggest that bilingualism may have protective effects against the early emergence of racial bias.

Singh, Leher↗

Evaluation of a variable dose acquisition technique for microcalcification and mass detection in digital breast tomosynthesis

In this article the authors evaluate a recently proposed variable dose (VD)-digital breast tomosynthesis (DBT) acquisition technique in terms of the detection accuracy for breast masses and microcalcification (MC) clusters. With this technique, approximately half of the total dose is used for one center projection and the remaining dose is split among the other tomosynthesis projection views. This acquisition method would yield both a projection view and a reconstruction view. One of the aims of this study was to evaluate whether the center projection alone of the VD acquisition can provide equal or superior MC detection in comparison to the 3D images from uniform dose (UD)-DBT. Another aim was to compare the mass-detection capabilities of 3D reconstructions from VD-DBT and UD-DBT. In a localization receiver operating characteristic (LROC) observer study of MC detection, the authors compared the center projection of a VD acquisition scheme (at 2 mGy dose) with detector pixel size of 100 {mu}m with the UD-DBT reconstruction (at 4 mGy dose) obtained with a voxel size of 100 {mu}m. MCs with sizes of 150 and 180 {mu}m were used in the study, with each cluster consisting of seven MCs distributed randomly within a small volume. Reconstructed images in UD-DBT were obtained from a projection set that had a total of 4 mGy dose. The current study shows that for MC detection, using the center projection alone of VD acquisition scheme performs worse with area under the LROC curve (A{sub L}) of 0.76 than when using the 3D reconstructed image using the UD acquisition scheme (A{sub L}=0.84). A 2D ANOVA found a statistically significant difference (p=0.038) at a significance level of 0.05. In the current study, although a reconstructed image was also available using the VD acquisition scheme, it was not used to assist the MC detection task which was done using the center projection alone. In the case of evaluation of detection accuracy of masses, the reconstruction with VD-DBT (A{sub L}=0.71) was compared to that obtained from the UD-DBT (A{sub L}=0.78). The authors found no statistically significant difference between the two (p-value=0.22), although all the observers performed better for UD-DBT.

61 RADIATION PROTECTION AND DOSIMETRY↗

The simulation of 3D microcalcification clusters in 2D digital mammography and breast tomosynthesis

Purpose: This work proposes a new method of building 3D models of microcalcification clusters and describes the validation of their realistic appearance when simulated into 2D digital mammograms and into breast tomosynthesis images. Methods: A micro-CT unit was used to scan 23 breast biopsy specimens of microcalcification clusters with malignant and benign characteristics and their 3D reconstructed datasets were segmented to obtain 3D models of microcalcification clusters. These models were then adjusted for the x-ray spectrum used and for the system resolution and simulated into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. Six radiologists were asked to distinguish between 40 real and 40 simulated clusters of microcalcifications in two separate studies on 2D mammography and tomosynthesis datasets. Receiver operating characteristic (ROC) analysis was used to test the ability of each observer to distinguish between simulated and real microcalcification clusters. The kappa statistic was applied to assess how often the individual simulated and real microcalcification clusters had received similar scores (''agreement'') on their realistic appearance in both modalities. This analysis was performed for all readers and for the real and the simulated group of microcalcification clusters separately. ''Poor'' agreement would reflect radiologists' confusion between simulated and real clusters, i.e., lesions not systematically evaluated in both modalities as either simulated or real, and would therefore be interpreted as a success of the present models. Results: The area under the ROC curve, averaged over the observers, was 0.55 (95% confidence interval [0.44, 0.66]) for the 2D study, and 0.46 (95% confidence interval [0.29, 0.64]) for the tomosynthesis study, indicating no statistically significant difference between real and simulated lesions (p > 0.05). Agreement between allocated lesion scores for 2D mammography and those for the tomosynthesis series was poor. Conclusions: The realistic appearance of the 3D models of microcalcification clusters, whether malignant or benign clusters, was confirmed for 2D digital mammography images and the breast tomosynthesis datasets; this database of clusters is suitable for use in future observer performance studies related to the detectability of microcalcification clusters. Such studies include comparing 2D digital mammography to breast tomosynthesis and comparing different reconstruction algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A virtual trial framework for quantifying the detectability of masses in breast tomosynthesis projection data

Purpose: Digital breast tomosynthesis (DBT) is a promising breast cancer screening tool that has already begun making inroads into clinical practice. However, there is ongoing debate over how to quantitatively evaluate and optimize these systems, because different definitions of image quality can lead to different optimal design strategies. Powerful and accurate tools are desired to extend our understanding of DBT system optimization and validate published design principles. Methods: The authors developed a virtual trial framework for task-specific DBT assessment that uses digital phantoms, open-source x-ray transport codes, and a projection-space, spatial-domain observer model for quantitative system evaluation. The authors considered evaluation of reconstruction algorithms as a separate problem and focused on the information content in the raw, unfiltered projection images. Specifically, the authors investigated the effects of scan angle and number of angular projections on detectability of a small (3 mm diameter) signal embedded in randomly-varying anatomical backgrounds. Detectability was measured by the area under the receiver-operating characteristic curve (AUC). Experiments were repeated for three test cases where the detectability-limiting factor was anatomical variability, quantum noise, or electronic noise. The authors also juxtaposed the virtual trial framework with other published studies to illustrate its advantages and disadvantages. Results: The large number of variables in a virtual DBT study make it difficult to directly compare different authors' results, so each result must be interpreted within the context of the specific virtual trial framework. The following results apply to 25% density phantoms with 5.15 cm compressed thickness and 500 {mu}m{sup 3} voxels (larger 500 {mu}m{sup 2} detector pixels were used to avoid voxel-edge artifacts): 1. For raw, unfiltered projection images in the anatomical-variability-limited regime, AUC appeared to remain constant or increase slightly with scan angle. 2. In the same regime, when the authors fixed the scan angle, AUC increased asymptotically with the number of projections. The threshold number of projections for asymptotic AUC performance depended on the scan angle. In the quantum- and electronic-noise dominant regimes, AUC behaviors as a function of scan angle and number of projections sometimes differed from the anatomy-limited regime. For example, with a fixed scan angle, AUC generally decreased with the number of projections in the electronic-noise dominant regime. These results are intended to demonstrate the capabilities of the virtual trial framework, not to be used as optimization rules for DBT. Conclusions: The authors have demonstrated a novel simulation framework and tools for evaluating DBT systems in an objective, task-specific manner. This framework facilitates further investigation of image quality tradeoffs in DBT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-130: Dosimetric Evaluation of Tissue Equivalent Gel Dosimeter Using Saccharide in Radiotherapy System

Purpose: In this study, the dose responses of the MAGIC gel with various concentrations and type of saccharide are examined to clarify the roles of mono and disaccharide in the polymerization process. Then we focused on the tissue equivalence and dose sensitivity of MAGIC gel dosimeters. Methods: The gel is composed of HPLC, 8% gelatin, 2 × 10-3 M L-ascorbic acid, 1.8 × 10-2 M hydroquinone, 8 × 10-5 M copper(II)sulfate and 9% methacrylic acid, new polymer gels are synthesized by adding glucose(monosaccharide), sucrose(disaccharide) and urea in the concentration range of 5∼35%. For irradiation of the gel, cesium-137 gamma-ray irradiator was used, radiation dose was delivered from 5∼50 Gy. MRI images of the gel were acquired by using a 3.0 T MRI system. Results: When saccharide and urea were added, the O/C, O/N and C/N ratios agreed with those of soft tissue with 1.7%. The dose-response of glucose and sucrose gel have slope-to-intercept ratio of 0.044 and 0.283 respectively. The slope-to-ratio is one important determinant of gel sensitivity. R-square values of glucose and sucrose gel dosimeters were 0.984 and 0.994 respectively. Moreover when urea were added, the slope-to-intercept ratio is 0.044 and 0.073 respectively. R-square values of mono and disaccharide gel were 0.973 and 0.989 respectively. When a saccharide is added into the MAGIC gel dosimeter, dose sensitivity is increased. However when urea were added, dose sensitivity is slightly decreased. Conclusion: In this study, it was possible to obtain the following conclusions by looking at the dose response characteristics after adding mono-, di-saccharide and urea to a MAGIC gel dosimeter. Saccharide was a tendency of increasing dose sensitivity with disaccharide. Sa.ccharide is cost effective, safe, soft tissue equivalent, and can be used under various experimental conditions, making it a suitable dosimeter for some radiotherapy applications.

60 APPLIED LIFE SCIENCES↗

Unzipping hBN with ultrashort mid-infrared pulses

Manipulating the nanostructure of materials is critical for numerous applications in electronics, magnetics, and photonics. However, conventional methods such as lithography and laser writing require cleanroom facilities or leave residue. We describe an approach to creating atomically sharp line defects in hexagonal boron nitride (hBN) at room temperature by direct optical phonon excitation with a mid-infrared pulsed laser from free space. We term this phenomenon “unzipping” to describe the rapid formation and growth of a crack tens of nanometers wide from a point within the laser-driven region. Formation of these features is attributed to the large atomic displacement and high local bond strain produced by strongly driving the crystal at a natural resonance. This process occurs only via coherent phonon excitation and is highly sensitive to the relative orientation of the crystal axes and the laser polarization. Its cleanliness, directionality, and sharpness enable applications such as polariton cavities, phonon-wave coupling, and in situ flake cleaving.

36 MATERIALS SCIENCE↗

Notes on correlation femtoscopy

The particle correlations at small relative velocities are sensitive to the space-time characteristics of the production processes on a femtometer scale owing to the effects of quantum statistics and finalstate interaction. Though the final-state interaction complicates the correlation analysis, it is an important source of information allowing for coalescence femtoscopy, correlation femtoscopy with unlike particles including access to the relative space-time asymmetries in particle production, and a study of strong interactions between specific particles. I will briefly discuss the history and basics of correlation femtoscopy, some of the recent results from femtoscopy of relativistic heavy-ion collisions, and their consequences.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observed Scaling in Clouds and Precipitation and Scale Incognizance in Regional to Global Atmospheric Models

We use observations of robust scaling behavior in clouds and precipitation to derive constraints on how partitioning of precipitation should change with model resolution. Our analysis indicates that 90-99% of stratiform precipitation should occur in clouds that are resolvable by contemporary climate models (e.g., with 200 km or finer grid spacing). Furthermore, this resolved fraction of stratiform precipitation should increase sharply with resolution, such that effectively all stratiform precipitation should be resolvable above scales of ~50 km. We show that the Community Atmosphere Model (CAM) and the Weather Research and Forecasting (WRF) model also exhibit the robust cloud and precipitation scaling behavior that is present in observations, yet the resolved fraction of stratiform precipitation actually decreases with increasing model resolution. A suite of experiments with multiple dynamical cores provides strong evidence that this `scale-incognizant' behavior originates in one of the CAM4 parameterizations. An additional set of sensitivity experiments rules out both convection parameterizations, and by a process of elimination these results implicate the stratiform cloud and precipitation parameterization. Tests with the CAM5 physics package show improvements in the resolution-dependence of resolved cloud fraction and resolved stratiform precipitation fraction.

atmospheric↗

Detecting localized trace species in air using radar resonance-enhanced multi-photon ionization

A microwave-scattering-based resonance-enhanced multi-photon ionization technique is used to detect molecular species such as NO, CO, Xe, and Ar in pure form, and for standoff detection of trace species in atmospheric pressure air. In this paper,the spectra, dynamics, and the detection limits of trace species in air are studied. We demonstrate 10 m scale standoff detection of NO, and show that the system has a linear response down to the parts in 10{sup 9} NO levels in ambient air.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RESULTS OF CESIUM MASS TRANSFER TESTING FOR NEXT GENERATION SOLVENT WITH HANFORD WASTE SIMULANT AP-101

SRNL has performed an Extraction, Scrub, Strip (ESS) test using the next generation solvent and AP-101 Hanford Waste simulant. The results indicate that the next generation solvent (MG solvent) has adequate extraction behavior even in the face of a massive excess of potassium. The stripping results indicate poorer behavior, but this may be due to inadequate method detection limits. SRNL recommends further testing using hot tank waste or spiked simulant to provide for better detection limits. Furthermore, strong consideration should be given to performing an actual waste, or spiked waste demonstration using the 2cm contactor bank. The Savannah River Site currently utilizes a solvent extraction technology to selectively remove cesium from tank waste at the Multi-Component Solvent Extraction unit (MCU). This solvent consists of four components: the extractant - BoBCalixC6, a modifier - Cs-7B, a suppressor - trioctylamine, and a diluent, Isopar L{trademark}. This solvent has been used to successfully decontaminate over 2 million gallons of tank waste. However, recent work at Oak Ridge National Laboratory (ORNL), Argonne National Laboratory (ANL), and Savannah River National Laboratory (SRNL) has provided a basis to implement an improved solvent blend. This new solvent blend - referred to as Next Generation Solvent (NGS) - is similar to the current solvent, and also contains four components: the extractant - MAXCalix, a modifier - Cs-7B, a suppressor - LIX-79{trademark} guanidine, and a diluent, Isopar L{trademark}. Testing to date has shown that this 'Next Generation' solvent promises to provide far superior cesium removal efficiencies, and furthermore, is theorized to perform adequately even in waste with high potassium concentrations such that it could be used for processing Hanford wastes. SRNL has performed a cesium mass transfer test in to confirm this behavior, using a simulant designed to simulate Hanford AP-101 waste.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sample Results from the Integrated Salt Disposition Program Macrobatch 5 Tank 21H Qualification MST, ESS and PODD Samples

Savannah River National Laboratory (SRNL) performed experiments on qualification material for use in the Integrated Salt Disposition Program (ISDP) Batch 5 processing. This qualification material was a composite created from recent samples from Tank 21H and archived samples from Tank 49H to match the projected blend from these two tanks. Additionally, samples of the composite were used in the Actinide Removal Process (ARP) and extraction-scrub-strip (ESS) tests. ARP and ESS test results met expectations. A sample from Tank 21H was also analyzed for the Performance Objectives Demonstration Document (PODD) requirements. SRNL was able to meet all of the requirements, including the desired detection limits for all the PODD analytes. This report details the results of the Actinide Removal Process (ARP), Extraction-Scrub-Strip (ESS) and Performance Objectives Demonstration Document (PODD) samples of Macrobatch (Salt Batch) 5 of the Integrated Salt Disposition Program (ISDP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Critical Experiment Design Phase 2 Report for Integral Request 441

This report documents the second phase of critical experiment design (CED-2) conducted as part of integral experiment request (IER) 441. The purpose of IER-441 is to develop a capability to test the epithermal/intermediate cross sections of materials at the Sandia National Laboratories’ (SNL’s) critical experiment facility using low-enriched uranium oxide fuel. This effort determined that the capability can be achieved using a varying number of test samples in a central test region of a hexagonally pitched lattice driven with a more moderated exterior region. The hollow test region can be changed to either contain a pure aluminum wall or a wall that incorporates a cadmium thermal flux filter. This report documents the development of final anticipated critical configurations using tantalum as the test sample material. Using the anticipated critical configurations, estimates of the experimental uncertainties and sensitivities of materials are performed in keeping with the CEdT process. A list of the new hardware necessary to perform the experiment is included.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of the top quark-antiquark pair charge asymmetry in events with highly boosted top quarks in proton-proton collisions at 13 TeV with the CMS detector

The top quark is the heaviest elementary particle, making it a unique tool to search for new physics. In this talk, I will present a new measurement of the top quark pair charge asymmetry for highly boosted top quarks decaying to a single lepton, missing transverse momentum and jets. The analysis is performed on 13TeV proton-proton collision data recorded by the CMS experiment during Run 2. We have defined a dedicated phase space that selects top quark-antiquark pairs with invariant mass greater than 750GeV in a semileptonic final state where the lepton is not necessarily isolated. This highly boosted sample is enhanced in valence quark production and thus expected to be more sensitive to deviations in the charge asymmetry caused by BSM processes. Dedicated tagging techniques are used to identify the decay products of hadronic top quarks and W bosons. An unfolding procedure is used to correct for detector resolution and acceptance, and inefficiencies in the event reconstruction. The result is presented in the full phase space at parton level and can be used as input to global EFT interpretations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗