Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

SU-F-J-75: Accuracy and Stability of Electron Density Measurements Across Patient Size Using Dual Energy CT

Purpose: Dual energy (DE) CT can be used to characterize tissue composition. One application of DE CT is to measure electron density (ED, rho) and atomic number (Z) for use in radiation therapy treatment planning. This work evaluated the accuracy and stability of ED estimation as patient size varied for both single-energy (SE) and DE CT. Methods: An ED phantom (CIRS) and four torso-shaped water tanks (lateral widths 15, 25, 35 and 45 cm) containing 8 tissue-simulating cylinders of known ED were scanned on a dual-source CT system (Siemens Somatom Force) in SE (120 kV) and DE (90/150Sn) modes. Additional scans were performed on the 15 and 25 cm water tanks using DE techniques of 70/150Sn and 80/150Sn, respectively. CTDIvol was matched for all SE and DE scans for a given phantom size. Images were reconstructed using quantitative kernels to preserve CT number accuracy. ED was estimated in each test cylinder and in solid and liquid water using calibration measurements acquired in the CIRS phantom (SE) and a Rho-Z algorithm (DE). Results: ED estimates showed good agreement with the nominal ED values when using Rho-Z (slope = 1.0051, R2 = 0.9982). Mean percent error was similar between SE (1.21%) and DE (1.28%). Mean deviation across patient size decreased 34% (1.43% with SE, 0.95% with DE). When compared to 90/150Sn, DE techniques of 70/150Sn and 80/150Sn showed mean differences in ED of 0.43% and 0.15%, respectively. Conclusion: While both DE Rho-Z and SE CT number calibration methods are both accurate for estimating ED, Rho-Z offers the advantages of having less variability across patient size, not requiring a phantom calibration, and being able to distinguish between materials of similar attenuation, but different chemical composition. Low kV DE pairs are an option in small patients due to lack of effect on ED accuracy. This research was supported by Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-15: Model-Based Multiscale Noise Reduction On Low Dose Cone Beam Projection

Purpose: To improve image quality of low dose cone beam CT for patient positioning in radiation therapy. Methods: In low dose cone beam CT (CBCT) imaging systems, Poisson process governs the randomness of photon fluence at x-ray source and the detector because of the independent binomial process of photon absorption in medium. On a CBCT projection, the variance of fluence consists of the variance of noiseless imaging structure and that of Poisson noise, which is proportional to the mean (noiseless) of the fluence at the detector. This requires multiscale filters to smoothen noise while keeping the structure information of the imaged object. We used a mathematical model of Poisson process to design multiscale filters and established the balance of noise correction and structure blurring. The algorithm was checked with low dose kilo-voltage CBCT projections acquired from a Varian OBI system. Results: From the investigation of low dose CBCT of a Catphan phantom and patients, it showed that our model-based multiscale technique could efficiently reduce noise and meanwhile keep the fine structure of the imaged object. After the image processing, the number of visible line pairs in Catphan phantom scanned with 4 ms pulse time was similar to that scanned with 32 ms, and soft tissue structure from simulated 4 ms patient head-and-neck images was also comparable with scanned 20 ms ones. Compared with fixed-scale technique, the image quality from multiscale one was improved. Conclusion: Use of projection-specific multiscale filters can reach better balance on noise reduction and structure information loss. The image quality of low dose CBCT can be improved by using multiscale filters.

60 APPLIED LIFE SCIENCES↗

Martensitic Transformation and Magnetic Properties of the CuAl, CuAlMn, and CuAlMnZn Alloys

In the present work, the effect of alloying elements on the phase transformation which are formed by cooling effect in CuAl, CuAlMn, and CuAlMnZn (wt%) alloys are investigated using scanning electron microscopy (SEM) and vibrating sample magnetometer (VSM) characterization techniques. From SEM observations, the martensite formation with different morphologies is observed in these alloys. But the results of the scanning electron microscope investigations presented in this work have not formed the precipitates in the CuAl alloy with Mn or Zn additions. We found that magnetic saturation and coercivity values decreased with the addition of Mn and Zn elements to the CuAl alloy. The findings confirmed the variation in magnetic properties, which occurred in the result of adding different alloying elements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Line scanning thermography for rapid nondestructive inspection of large scale composites

As next generation structures are utilizing larger amounts of composite materials, a rigorous and reliable method is needed to inspect these structures in order to prevent catastrophic failure and extend service life. Current inspection methods, such as ultrasonic, generally require extended down time and man hours as they are typically carried out via point-by-point measurements. A novel Line Scanning Thermography (LST) System has been developed for the non-contact, large-scale field inspection of composite structures with faster scanning times than conventional thermography systems. LST is a patented dynamic thermography technique where the heat source and thermal camera move in tandem, which allows the continuous scan of long surfaces without the loss of resolution. The current system can inspect an area of 10 in{sup 2} per 1 second, and has a resolution of 0.05x0.03 in{sup 2}. Advanced data gathering protocols have been implemented for near-real time damage visualization and post-analysis algorithms for damage interpretation. The system has been used to successfully detect defects (delamination, dry areas) in fiber-reinforced composite sandwich panels for Navy applications, as well as impact damage in composite missile cases and armor ceramic panels.

42 ENGINEERING↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

Highly ordered three-dimensional macroporous carbon spheres for determination of heavy metal ions

Highlights: Black-Right-Pointing-Pointer Highly ordered three dimensional macroporous carbon spheres (MPCSs) were prepared. Black-Right-Pointing-Pointer MPCS was covalently modified by cysteine (MPCS-CO-Cys). Black-Right-Pointing-Pointer MPCS-CO-Cys was first time used in electrochemical detection of heavy metal ions. Black-Right-Pointing-Pointer Heavy metal ions such as Pb{sup 2+} and Cd{sup 2+} can be simultaneously determined. -- Abstract: An effective voltammetric method for detection of trace heavy metal ions using chemically modified highly ordered three dimensional macroporous carbon spheres electrode surfaces is described. The highly ordered three dimensional macroporous carbon spheres were prepared by carbonization of glucose in silica crystal bead template, followed by removal of the template. The highly ordered three dimensional macroporous carbon spheres were covalently modified by cysteine, an amino acid with high affinities towards some heavy metals. The materials were characterized by physical adsorption of nitrogen, scanning electron microscopy, and transmission electron microscopy techniques. While the Fourier-transform infrared spectroscopy was used to characterize the functional groups on the surface of carbon spheres. High sensitivity was exhibited when this material was used in electrochemical detection (square wave anodic stripping voltammetry) of heavy metal ions due to the porous structure. And the potential application for simultaneous detection of heavy metal ions was also investigated.

36 MATERIALS SCIENCE↗

Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts

Industrial X-ray computed tomography (XCT) enables non-destructive inspection of additively manufactured (AM) parts, but high-resolution scanning requires long acquisition times and significant computational resources, limiting throughput in production environments. Super-resolution techniques can recover high-resolution information from low-resolution scans, but existing methods face a trade-off between 2D approaches that ignore inter-slice information and 3D methods that are computationally prohibitive for practical deployment. To address this trade-off, we propose a 2.5D deep learning-based super-resolution approach that uses seven neighbouring low-resolution slices to super-resolve the centre slice. This work evaluates the method on real XCT scans of steel AM parts, comparing reconstruction quality and flaw detection performance of 2D, 2.5D, and 3D ESRGAN-based super-resolution methods. Results demonstrate that 2.5D super-resolution significantly improves detection of small, process-induced flaws (e.g. porosity) compared to 2D methods, while avoiding the prohibitive computational burden of full 3D approaches. These findings provide initial evidence of 2.5D super-resolution as a practical, deployable solution for improving flaw detection in high-throughput industrial XCT inspection.

X-ray CT↗

Sensing Current and Forces with SPM

Atomic force microscopy (AFM) and scanning tunneling microscopy (STM) are well established techniques to image surfaces and to probe material properties at the atomic and molecular scale. In this review, we show hybrid combinations of AFM and STM that bring together the best of two worlds: the simultaneous detection of atomic scale forces and conduction properties. We illustrate with several examples how the detection of forces during STM and the detection of currents during AFM can give valuable additional information of the nanoscale material properties.

36 MATERIALS SCIENCE↗

Precise mass detector based on carbon nanooscillator

Precise mass detectors based on an amorphous carbon nanowires, which localized on the top of a tungsten tip were fabricated and investigated. The nanowires were grown in the scanning electron microscope (SEM) chamber using focused electron beam technique. The movement trajectories and amplitude-frequency characteristics of the carbon nanowire oscillators were visualized at low and ambient pressure using SEM and confocal laser scanning microscope (CLSM), respectevely. The SiO{sub 2} and TiO{sub 2} nanospheres were clamped on the top of the carbon nanowires. The manipulations of nanospheres were provided by means of dielectrophoretic force in SEM. The sensitivity of the mass detector based on the carbon nanowire oscillator was estimated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sub-10 second fly-scan nano-tomography using machine learning

Abstract X-ray computed tomography is a versatile technique for 3D structure characterization. However, conventional reconstruction algorithms require that the sample not change throughout the scan, and the timescale of sample dynamics must be longer than the data acquisition time to fulfill the stable sample requirement. Meanwhile, concerns about X-ray-induced parasite reaction and sample damage have driven research efforts to reduce beam dosage. Here, we report a machine-learning-based image processing method that can significantly reduce data acquisition time and X-ray dose, outperforming conventional approaches like Filtered-Back Projection, maximum-likelihood, and model-based maximum-a-posteriori probability. Applying machine learning, we achieve ultrafast nano-tomography with sub-10 second data acquisition time and sub-50 nm pixel resolution in a transmission X-ray microscope. We apply our algorithm to study dynamic morphology changes in a lithium-ion battery cathode under a heating rate of 50 o C min −1 , revealing crack self-healing during thermal annealing. The proposed method can be applied to various tomography modalities.

36 MATERIALS SCIENCE↗

Characterization of ZnAl cast alloys with Na addition

This study was aimed at evaluating the microstructural change and thermal, electrical and mechanical properties with the addition of Na to eutectic ZnAl alloys. Solders based on eutectic ZnAl containing 0.2 to 3.0 (wt.%) of Na were developed for high temperature solder. Differential scanning calorimetry (DSC) measurements were performed to determine the melting temperatures of the alloys. Thermal linear expansion and electrical resistivity measurements were performed over − 50 °C to 300 °C and 30 °C to 300 °C temperature ranges, respectively. The microstructure of the specimens was analyzed using scanning (SEM) and transmission electron microscopy (TEM) techniques. Chemical microanalysis was performed by energy-dispersive X-ray spectroscopy (EDS) on SEM and TEM. The precipitates of NaZn{sub 13} were confirmed by X-ray diffraction (XRD) measurements and selected area electron diffraction (SAED) techniques. The addition of Na to eutectic ZnAl alloy increased the electrical resistivity and reduced the coefficient of thermal expansion; however, the melting point did not change. The mechanical properties, strain and microhardness increased with Na content in alloys. - Highlights: • High temperature soldering materials of ZnAl with Na were designed and characterized. • Precipitates of NaZn{sub 13}were observed and confirmed using TEM and XRD. • Addition of Na to eutectic ZnAl cussed increased mechanical properties. • NaZn{sub 13} caused increased electrical resistivity and microhardness, and reduced the CTE.

36 MATERIALS SCIENCE↗

Graphene engineering by neon ion beams

Achieving the ultimate limits of materials and device performance necessitates the engineering of matter with atomic, molecular, and mesoscale fidelity. While common for organic and macromolecular chemistry, these capabilities are virtually absent for 2D materials. In contrast to the undesired effect of ion implantation from focused ion beam (FIB) lithography with gallium ions, and proximity effects in standard e-beam lithography techniques, the shorter mean free path and interaction volumes of helium and neon ions offer a new route for clean, resist free nanofabrication. Furthermore, with the advent of scanning helium ion microscopy, maskless He + and Ne + beam lithography of graphene based nanoelectronics is coming to the forefront. Here, we will discuss the use of energetic Ne ions in engineering graphene devices and explore the mechanical, electromechanical and chemical properties of the ion-milled devices using scanning probe microscopy (SPM). By using SPM-based techniques such as band excitation (BE) force modulation microscopy, Kelvin probe force microscopy (KPFM) and Raman spectroscopy, we demonstrate that the mechanical, electrical and optical properties of the exact same devices can be quantitatively extracted. Additionally, the effect of defects inherent in ion beam direct-write lithography, on the overall performance of the fabricated devices is elucidated.

36 MATERIALS SCIENCE↗

Chemical and mechanical consequences of environmental barrier coating exposure to calcium-magnesium-aluminosilicate.

The success of Si-based ceramics as high-temperature structural materials for gas turbine applications relies on the use of environmental barrier coatings (EBCs) with low silica activity, such as Ba{sub 1-x}Sr{sub x}Al{sub 2}Si{sub 2}O{sub 8} (BSAS), which protect the underlying components from oxidation and corrosion in combustion environments containing water vapor. One of the current challenges concerning EBC lifetime is the effect of sandy deposits of calcium-magnesium-aluminosilicate (CMAS) glass that melt during engine operation and react with the EBC, changing both its composition and stress state. In this work, we study the effect of CMAS exposure at 1300 C on the residual stress state and composition in BSAS-mullite-Si-SiC multilayers. Residual stresses were measured in BSAS multilayers exposed to CMAS for different times using high-energy X-ray diffraction. Their microstructure was studied using a combination of scanning electron microscopy and transmission electron microscopy techniques. Our results show that CMAS dissolves the BSAS topcoat preferentially through the grain boundaries, dislodging the grains and changing the residual stress state in the topcoat to a nonuniform and increasingly compressive stress state with increasing exposure time. The presence of CMAS accelerates the hexacelsian-to-celsian phase transformation kinetics in BSAS, which reacts with the glass by a solution-reprecipitation mechanism. Precipitates have crystallographic structures consistent with Ca-doped celsian and Ba-doped anorthite.

36 MATERIALS SCIENCE↗

Development of Multifunctional Thin Film Based X-Ray Intensity Filters for Space-Based Payloads

We report the development, thorough characterizations and space worthiness studies of multifunctional aluminized film as x-ray intensity filter for space-based payloads, suitably designed to place in Sun–Earth Lagrangian (L1) point. The L1 point is the ideal location for uninterrupted observation of Sun to study the solar flares in hard x-rays. For our specific purpose, we make use of two different types of x-ray detectors (e.g., CdTe and CZT) which are generally used for hard x-ray studies in the energy band of 5 to 200 keV. Further, these aforesaid two detectors require specified thermal control characteristic for optimal performance. Aluminization of Kapton films is proposed which would satisfy the thermo-optical and x-ray transmission requirements of the proposed payload. The developed aluminized films are thoroughly studied by field emission scanning electron microscopy and atomic force microscopy techniques for micro-structural characteristic, x-ray diffraction for phase purity, nanoindentation for mechanical integrity at micro-structural length scale and spectrophotometer for thermo-optical properties. X-ray transmission test is carried out with two radioactive sources, namely {sup 55}Fe and {sup 241}Am, with various aluminized Kapton layer combinations. Finally, space worthiness of the aluminized Kapton films is examined by accelerated environments, e.g. humidity, thermal cycling and thermo-vacuum tests.

36 MATERIALS SCIENCE↗

Applying Acoustic Emission to Large Format Additive Manufacturing

Large format additive manufacturing (AM) is being adapted as a method of producing large structures in a short lead time and cost-effective way. With the growing advancement in AM techniques and application, machine monitoring and part qualification is highly needed. There has been leading research focused on the manufacturing development and feedstock material but minimum research on the structural health monitoring (SHM), defect detection, and nondestructive evaluation (NDE) for large format AM. Scanning large structure using conventional nondestructive testing (NDT) techniques, such as ultrasound or X-ray, and searching for potential defects can be very time consuming, challenging and cost prohibitive. Acoustic emission (AE) is a passive technique that can be used to monitor and locate defect progression in large structures by distributing group of sensors around the part. This research outlines the necessary procedure for implementing AE to AM as a reliability method. The topics this research will display are: (a) Wave propagation/velocity evaluation, (b) an AE attenuation characterization for the anisotropic printed structure and material, (c) background noise measurements of the extruder and gantry system, and (d) assist in optimal sensor selection and placement for monitoring large AM structures with demonstration. This work establishes the foundation for scaling up the SHM-AE system for the large additive platform.

Spencer, Ryan↗

Importance of Martensite Spatial Distribution at Large Volume Fractions in Imparting Ductility in High-Strength Dual-Phase Steel

Controlled austenite decomposition in a cold-rolled steel was carried out in a hot-dip process simulator with different inter-critical annealing process parameters to produce dual-phase steel consisting of martensite phase fraction above 50%. The evolving microstructure was characterized by using scanning electron microscope and electron backscattered diffraction techniques. Macro- and micro-texture was characterized by using x-ray diffraction and electron backscattered diffraction techniques, respectively. Uniaxial tensile deformation showed a very good combination of ultra-high strength above 900 MPa with uniform elongation of above 7%. An anomalous increase in ductility was observed for steel with high martensite volume fraction of 62.2% compared to that of lower fraction of 52.3%, indicating the influence of size and spatial distribution arrangement of ferrite and martensite phases. The enhancement in the ductility with high strength was attributed to the improved plastic deformability of hard fine martensite phase along with fine ferrite surrounding it. The nature of micro- and macro-texture was also found to affect strain partitioning compatibility between ferrite and martensite in this study.

36 MATERIALS SCIENCE↗

Hydrothermal synthesis of a novel non-stoichiometric cubic bismuth phosphate (Bi{sub 12}(Bi{sub 4/5–5x}P{sub 5x})O{sub 19.2+5x}) crystal and the coexistence of multilevel Kink-Terrace-Step structures on Kossel (1 0 0) surface

- Highlights: • Pure cubic phase could be synthesized at high alkalinity. • The height of the lowest kinked [0 1 0] steps was about half of the unit cell. • Multilevel Kink-Terrace-Step structures coexisted on Kossel (1 0 0) surface. • Multilevel growth units are PO{sub 4}{sup −} incorporating into the channels of Bi–O frameworks. - Abstract: Nonstoichiometric cubic bismuth phosphate crystals were synthesized and grown by hydrothermal method. Under high alkalinity condition, three dimensional nuclei were generated and combined into cubic plates. The cubic bismuth phosphate crystals were combined by the corresponding cubic plates with various defects and rough surfaces. The cubic plates made (1 0 0) surface of the crystal cleavage face. Additionally, multilevel Kink-Terrace-Step structures on Kossel (1 0 0) surface were characterized through scanning electron microscopy and atomic force microscope techniques, respectively. It revealed that the lowest level Kink-Terrace-Step structure was in nano-scale, and the height of the elemental kinked [0 1 0] steps was about half of the unit cell. The elemental kinked [0 1 0] steps could bunch together and consequently constructed a higher level of Kink-Terrace-Step structures. As a result, multilevel Kink-Terrace-Step structures coexisted on the Kossel (1 0 0) surface of bismuth phosphate crystal, which were owing to the coexistence of multilevel growth units in crystal growth system.

36 MATERIALS SCIENCE↗

Fast Scanning Probe Microscopy via Machine Learning: Non-Rectangular Scans with Compressed Sensing and Gaussian Process Optimization

Fast scanning probe microscopy enabled via machine learning allows for a broad range of nanoscale, temporally resolved physics to be uncovered. However, such examples for functional imaging are few in number. Here, using piezoresponse force microscopy (PFM) as a model application, a factor of 5.8 reduction in data collection using a combination of sparse spiral scanning with compressive sensing and Gaussian process regression reconstruction is demonstrated. It is found that even extremely sparse spiral scans offer strong reconstructions with less than 6% error for Gaussian process regression reconstructions. Further, the error associated with each reconstructive technique per reconstruction iteration is analyzed, finding the error is similar past ≈15 iterations, while at initial iterations Gaussian process regression outperforms compressive sensing. Finally, this study highlights the capabilities of reconstruction techniques when applied to sparse data, particularly sparse spiral PFM scans, with broad applications in scanning probe and electron microscopies.

36 MATERIALS SCIENCE↗