Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST PROTOCOL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

A Ground Testing Program to Verify Lunar Dust-Tolerant Hardware for the Artemis Mission

In preparation for NASA’s Artemis Mission that will return humans to the surface of moon by 2024, an extensive test campaign will be undertaken to understand the effects of lunar dust contamination on equipment. Historically, early Apollo astronauts were affected by lunar dust that entered the cabin after their extravehicular activities, and subsequent missions had various cleaning protocols to reduce the impact of the contamination. The longest stays on the lunar surface were Apollo 15, 16, and 17 (just over three days), so equipment and suits were required to operate reliably for a relatively short duration. The ultimate goal of Artemis is a sustained human presence on the lunar surface, beginning with Artemis 3 which targets a six-and-a-half day surface deployment. This requires the design and testing of dust-tolerant infrastructure. Ground testing with aerosolized lunar dust simulants in a specialized chamber is an inexpensive way to verify the performance of equipment. Chambers equipped with various powder dispersers and analysis instrumentation can explore a variety of realistic scenarios relevant to lunar surface missions, from the interaction of dust with sensitive surfaces such as solar panels, textiles, radiators, and scientific equipment, to the effects of dust as it intrudes into habitable areas. These experiments require careful consideration of the expected mass concentrations, aerosolization methods, and transport properties of dust. Instruments that use light-scattering techniques to measure mass concentrations require calibration against lunar simulants for improved accuracy, and different simulants may have different calibration factors. Test facilities, laboratory setup and test methods for aerosolizing lunar simulant will be described along with relevant aerosol instruments and calibration efforts.

Benjamin J Sumlin↗

Effect of Radiotherapy Techniques (IMRT vs. 3D-CRT) on Outcome in Patients With Intermediate-Risk Rhabdomyosarcoma Enrolled in COG D9803-A Report From the Children's Oncology Group

Purpose: To compare the dosimetric parameters of intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) in patients with intermediate-risk rhabdomyosarcoma and to analyze their effect on locoregional control and failure-free survival (FFS). Methods and Materials: The study population consisted of 375 patients enrolled in the Children's Oncology Group protocol D9803 study, receiving IMRT or 3D-CRT. Dosimetric data were collected from 179 patients with an available composite plan. The chi-square test or Fisher's exact test was used to compare the patient characteristics and radiotherapy parameters between the two groups. The interval-to-event outcomes were estimated using the Kaplan-Meier method and compared using log-rank tests. Cox proportional hazards regression analysis was used to examine the effect of the treatment technique on FFS after adjusting for primary site and risk group. Results: The median follow-up time was 5.7 and 4.2 years for patients receiving 3D-CRT and IMRT, respectively. No differences in the 5-year failure of locoregional control (18% vs. 15%) or FFS (72% vs. 76%) rates were noted between the two groups. Multivariate analysis revealed no association between the two techniques and FFS. Patients with primary tumors in parameningeal sites were more likely to receive IMRT than 3D-CRT. IMRT became more common during the later years of the study. Patients receiving IMRT were more likely to receive >50 Gy, photon energy of {<=}6 MV, and >5 radiation fields than those who received 3D-CRT. The coverage of the IMRT planning target volume by the prescription dose was improved compared with the coverage using 3D-CRT with similar target dose heterogeneity. Conclusions: IMRT improved the target dose coverage compared with 3D-CRT, although an improvement in locoregional control or FFS could not be demonstrated in this population. Future studies comparing the integral dose to nontarget tissue and late radiation toxicity between the two groups are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmarking noise extrapolation with the OpenPulse control framework

Distilling precise estimates from noisy intermediate scale quantum (NISQ) data has recently attracted considerable attention Kandala et al., Nature (London) 567, 491 (2019). In order to augment digital qubit metrics, such as gate fidelity, we discuss analog error mitigability, i.e., the ability to accurately distill precise observable estimates, as a hybrid quantum classical computing benchmarking task. Specifically, using Rabi oscillations as a test program, we characterize single qubit error rates on IBM's Poughkeepsie superconducting quantum hardware, incorporate control-mediated noise dependence into a generalized rescaling protocol, and analyze how noise characteristics influence Richardson extrapolation-based error mitigation. Finally, our results identify regions in the space of Hamiltonian control fields and circuit depth which are most amenable to reliable noise extrapolation, as well as shed light on how low-level hardware characterization can be used as a predictive tool for uncertainty quantification in error-mitigated NISQ computations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Helium Vessel Welding Process for SNS PPU Cavities

The Spallation Neutron Source Proton Power Upgrade cavities are produced by Research Instrument with all the cavity processing done at vendor sites with final chemistry applied to the cavity to be electropolishing. Cavities are delivered to Jefferson Lab, ready to be tested. One of the tasks to be completed before the arrival of production-ready PPU cavities is to develop a robust helium vessel welding protocol. We have successfully developed the process and applied it to three six-cell high beta cavities. Here, we present the summary of RF results, welding process development, and post helium vessel RF results.

Dhakal, P.↗

Evaluation of Acoustic Channel Capacity for Complex Piping Topology

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through physical barriers, such as the containment building wall. In addition, this approach provides physical cybersecurity since the pipe becomes an analog communication channel which is difficult to eavesdrop on and difficult to sever. In prior work, a laboratory bench-scale system consisting of a six foot-long straight section of nuclear grade stainless steel pipe and high-temperature ultrasonic LiNbO 3 transducers was assembled. The lab systems was used for communication protocol development and preliminary data transmission demonstration. Next phase of project development involves deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Generalizable Web User Interface for Scalable and Streamlined Deployment of Building Energy Management Systems in Small and Medium-Sized Commercial Buildings

Small and medium-sized commercial buildings (SMCBs) comprise 94% of US commercial buildings yet face significant barriers to implementing building energy management systems despite advances in smart device technology. Existing solutions present critical limitations: cloud-based API solutions simplify deployment but create vendor lock-in constraints; commercial integrated software solutions ensure compatibility via standardized protocols but require substantial cost and technical expertise; open-source IoT platforms offer cost-effective vendor independence but provide insufficient standardized protocol support for commercial building automation. This research presents a generalizable web user interface framework that bridges the gap between evolving smart device capabilities and lagging software infrastructure for SMCBs. The proposed system integrates VOLTTRON open-source middleware with an automated configuration converter that transforms unified specifications written in YAML, a human-readable data-serialization format, into system-specific files, streamlining manual setup processes. The vendor-agnostic architecture supports industry-standard protocols (BACnet and Modbus) and semantic building models while providing adaptive web interfaces that dynamically adjust to various building configurations. Demonstrations through simulation-based testing and a field deployment show automatic interface adaptation across heterogeneous HVAC systems and multizone monitoring. The automated configuration converter also substantially reduces labor-intensive setup.

Chung, Jihoon [ORNL] (ORCID:0000000184880815)↗

Assessment of the pharmacodynamics of intranasal, intravenous and oral scopolamine

Space motion sickness is an important issue in the space medical sciences program. One of the objectives of the ongoing clinical experimental protocol Pharmacokinetics of Intranasal Scopolamine in Normal Subjects is to evaluate the pharmacodynamics of scopolamine using salivary flow rate and pH profiles and cognitive performance tests as pharmacodynamic parameters. Normal volunteers collected saliva and performed the NTI Multiresource Performance Battery tests at designed time intervals to establish control saliva flow rates, salivary pH profiles, and the characteristics of the learning curve for the performance program under normal conditions. In the clinical part of the study, saliva samples and performance test scores are collected from healthy nonsmoking subjects after receiving a single 0.4 mg dose of either intranasal, intravenous, or oral scopolamine.

Tietze, Karen J.↗

The effects of in-flight treadmill exercise on postflight orthostatic tolerance

In-flight aerobic exercise is thought to decrease the deconditioning effects of microgravity. Two deconditioning characteristics are the decreases in aerobic capacity (maximum O2 uptake) and an increased cardiovascular response to orthostatic stress (supine to standing). Changes in both parameters were examined after Shuttle flights of 8 to 11 days in astronauts who performed no in-flight exercise, a lower than normal volume of exercise, and a near-normal volume of exercise. The exercise regimen was a traditional continuous protocol. Maximum O2 uptake was maintained in astronauts who completed a near-normal exercise volume of in-flight exercise. Cardiovascular responses to stand test were equivocal among the groups. The use of the traditional exercise regimen as a means to maintain adequate orthostatic responses produced equivocal responses. A different exercise prescription may be more effective in maintaining both exercise capacity and orthostatic tolerance.

Siconolfi, Steven F.↗

Enhanced vagal baroreflex response during 24 h after acute exercise

We evaluated carotid-cardiac baroreflex responses in eight normotensive men (25-41 yr) on two different test days, each separated by at least 1 wk. On one day, baroreflex response was tested before and at 3, 6, 12, 18, and 24 h after graded supine cycle exercise to volitional exhaustion. On another day, this 24-h protocol was repeated with no exercise (control). Beat-to-beat R-R intervals were measured during external application of graded pressures to the carotid sinuses from 40 to -65 mmHg; changes of R-R intervals were plotted against carotid pressure (systolic pressure minus neck chamber pressure). The maximum slope of the response relationship increased (P less than 0.05) from preexercise to 12 h (3.7 +/- 0.4 to 7.1 +/- 0.7 ms/mmHg) and remained significantly elevated through 24 h. The range of the R-R response was also increased from 217 +/- 24 to 274 +/- 32 ms (P less than 0.05). No significant differences were observed during the control 24-h period. An acute bout of graded exercise designed to elicit exhaustion increases the sensitivity and range of the carotid-cardiac baroreflex response for 24 h and enhances its capacity to buffer against hypotension by increasing heart rate. These results may represent an underlying mechanism that contributes to blood pressure stability after intense exercise.

Vagus Nerve/physiology↗

The NDSC ozone and temperature lidar alogorithm intercomparison ubutuatuve (A2I): project overview

In September 2003, the Lidar Working Group (LWG) of the Network for Detection of Stratospheric Change (NDSC) initiated an extensive project to compare the ozone and temperature algorithms used within NDSC. This initiative, referred to later as Algorithm Intercomparison Initiative (A2I), uses simulated lidar signals to test and compare various parts of the ozone and temperature lidar algorithms. In addition to the fact that it meets the requirement of the NDSC protocols, this exercise allows the detailed assessment, by all the participants, of some of the sources and magnitudes of various uncertainties associated with the algorithms, and/or with the theoretical assumptions made in these algorithms. The outcome of the A21 is to try to find common grounds in the way ozone and temperature can be retrieved in order to reduce and possibly eradicate discrepancies due to algorithm issues alone. Specific issues such as homogenizing the choice of Rayleigh extinction cross-sections, ozone absorption cross-sections, a priori information, and the definition of the vertical resolutions are among the primary targets of the A21 outcome.

lidar↗

AMS Prototyping Activities

This slide presentation reviews the activity around the Asynchronous Message Service (AMS) prototype. An AMS reference implementation has been available since late 2005. It is aimed at supporting message exchange both in on-board environments and over space links. The implementation incoroporates all mandatory elements of the draft recommendation from July 2007: (1) MAMS, AMS, and RAMS protocols. (2) Failover, heartbeats, resync. (3) "Hooks" for security, but no cipher suites included in the distribution. The performance is reviewed, and a Benchmark latency test over VxWorks Message Queues is shown as histograms of a count vs microseconds per 1000-byte message

AMS (Asynchronous Message Service)↗

Command and Control Software Development

As NASA’s role in spaceflight operations change, so too does its design priorities. NASA’s flagship venture, the Space Launch System (SLS), is being created primarily to explore deep space. While commercial partners conduct low Earth orbit resupplies, tests, and even transportation of astronauts, NASA can divert more resources to more exciting projects - going back to the moon, or onwards to Mars. In the short term, this goal manifests in the upcoming Exploration Mission-1 (EM-1) test of the SLS, slated for as early as 2019. SLS, with the Orion capsule, will travel farther than any human-rated spacecraft has gone before. As the most powerful launch vehicle ever created, SLS requires many new innovations to ensure mission success. One such technology is the launch control software, which is the focus of this internship. The SLS launch control software is composed of many functions, all of which require rigorous testing to meet the standard of life-critical code. To facilitate easier testing, the first project I undertook was to customize the open-source tool Wireshark to the software team’s needs. Wireshark is a network protocol analyzer that can take in information about custom information packets. The launch control software will have several protocols that are custom to NASA. I ensured that all necessary component files were the correct file type and in the correct structure for Wireshark to compile. Having allowed Wireshark access to understand custom NASA data packets, testers of the launch control software will be able to find anomalies easier.

Wang, Zhengdong↗

Fe(exp3) - A Monte Carlo Simulation Capability for Evaluation of New Air Traffic Management Concepts

The concepts of unmanned aircraft system traffic management (UTM) and urban air mobility (UAM) introduce high-density operations in low-altitude airspace and will change the paradigm of the traditional air traffic system. The Flexible engine for Fast-time evaluation of Flight environments (Fe3) provides the capability of statistically analyzing high-density, high-fidelity, and low-altitude traffic system without conducting infeasible and cost-prohibitive flight tests that involve a large volume of aerial vehicles. With this simulation capability, stakeholders can study the impacts of critical factors, define requirements, policies, and protocols needed to support a safe yet efficient traffic system, assess operational risks, and optimize flight schedules. This work provides an introduction to this simulation tool including its architecture and various models involved. Its performance and applications in high density air traffic operations are also presented.

Paralellization↗

Real-Time Culture-Independent Microbial Profiling Onboard the International Space Station using Nanopore Sequencing

For the past two decades, microbial monitoring of the International Space Station (ISS) has relied on culture-dependent methods that require return to Earth for analysis. This has a number of limitations, with the most significant being bias towards the detection of culturable organisms and the inherent delay between sample collection and ground-based analysis. In recent years, portable and easy-to-use molecular-based tools, such as Oxford Nanopore Technologies’ MinION™ sequencer and miniPCR bio’s miniPCR™ thermal cycler, have been validated onboard the ISS. Here, we report on the development, validation, and implementation of a swab-to-sequencer method that provides a culture-independent solution to real-time microbial profiling onboard the ISS. Method development focused on analysis of swabs collected in a low-biomass environment with limited facility resources and stringent controls on allowed processes and reagents. ISS-optimized procedures included enzymatic DNA extraction from a swab tip, bead-based purifications, altered buffers, and the use of miniPCR and the MinION. Validation was conducted through extensive ground-based assessments comparing current standard culture-dependent and newly developed culture-independent methods. Similar microbial distributions were observed between the two methods; however, as expected, the culture-independent data revealed microbial profiles with greater diversity. Protocol optimization and verification was established during NASA Extreme Environment Mission Operations (NEEMO) analog missions 21 and 22, respectively. Unique microbial profiles obtained from analog testing validated the swab-to-sequencer method in an extreme environment. Finally, four independent swab-to-sequencer experiments were conducted onboard the ISS by two crewmembers. Microorganisms identified from ISS swabs were consistent with historical culture-based data, and primarily consisted of commonly observed human-associated microbes. This simplified method has been streamlined for high ease-of-use for a non-trained crew to complete in an extreme environment, thereby enabling environmental and human health diagnostics in real-time as future missions take us beyond low-Earth orbit.

microbiology↗

The Universal Space Transponder: A Next Generation Software Defined Radio

The Universal Space Transponder (UST) is a next generation transponder developed at the Jet Propulsion Laboratory to meet a large variety of telecom, navigation, and radio science needs for future deep-space and near-Earth missions. This paper details the UST software defined radio design and describes how the combination of a modular hardware architecture and in-flight reprogrammability enables a new level of flexibility and expandability for a space transponder. The UST uses common power and digital processing assemblies that can be integrated with a variety of RF modules and is capable of simultaneous, multiband operations with data rates up to 37.5 Mbps RX and 300 Mbps TX. This allows a single radio to support all the direct-to-Earth and relay communication requirements for even complex mission scenarios, reducing the total cost, mass, and power. The discussion includes a description of the current UST engineering models that have been built and tested, as well as details about the next generation capabilities supported by UST, including advanced link coding and modulation, radiometric techniques, and in-radio protocol handling. Details are also presented on RF modules and digital processing in development for radio science and astronomy purposes, including a bistatic radar receiver and broadband planetary emissions receiver. These will demonstrate the ability to integrate low-cost science instruments into the UST architecture, further expanding the versatility of the UST.

Jedrey, Thomas↗

Issues on a tritium measurement system's qualification on a dismantling site

In order to choose the suitable outlet, final disposal of radioactive package requires good knowledge of radiological characteristics of the waste. As part of a nuclear facility's dismantling within tritium proceeds, {sup 3}H contamination is evaluated by using wipe tests which are measured by liquid scintillation. The industrialist's choice is a triple coincidence to double coincidence ratio (TDCR) method with a dry counting protocol. The initial protocol had been defined to reduce the quantity of radioactive liquid waste and to perform an automatic quenching correction. A based on TDCR method liquid scintillation analyser was installed on the decommissioning site. It had had to be used by operator non specialized in metrology, This poster presents the laboratory's feedback on the use of the TDCR method on a site: - problems encountered about protocol on a decommissioning site - protocol adjustments and their consequences. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Value-based Insights from the Implementation of Hierarchical Control for Energy Savings and Demand Response in Residential Premises

As the adoption of distributed energy resources and electric vehicles at residential customer premises increases exponentially, behind-the-meter assets can be utilized to achieve energy cost reduction and demand response through coordination and control strategies. A hierarchical control architecture from the utility headend to residential premises is implemented to attain these objectives. This paper extracts the values from the development, implementation, and deployment of that control hierarchy. The development of the control philosophy is built upon the existing advanced metering infrastructure, communication protocols, and industry-compatible application programming interfaces. Results are presented visually with analytical insights by utilizing the data from hardware-in-the-loop testing and simulation analysis out of the collected data from the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗