Search NASA⌕ Search

SEARCH · Search NASA

Results for “Workflow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Minimizing the Electromechanical Stresses in Poloidal Field Coils by Optimizing their Numbers and Locations using FREDA Framework

Poloidal field (PF) and central solenoid (CS) coils play a crucial role in sustaining the equilibrium and preserving the shape of highly confined tokamak plasmas. Ensuring that PF coil current and mechanical stress stay within superconducting and structural limitations is an important check in the design assessment. Minimizing the PF coil currents and mechanical stresses influences reliability, cost, and performance. A free-boundary MHD equilibrium code—FreeGS is employed within the fusion reactor design and assessment (FREDA) whole facility modeling (WFM) framework to construct the plasma equilibrium based on the configuration and currents in the PF coils. Here, we present the capability of the FreeGS code to minimize the currents, forces, and electromagnetic stresses on the PF coils by optimizing their number, sizes, structures, and locations while maintaining an MHD stable plasma configuration with a large confinement factor. The workflow is initialized with a configuration of plasma parameters and coils’ locations from the 0-D tokamak build systems code in the FREDA framework. Then, FreeGS is called to calculate the initial equilibrium at the minimum total current in PF coils. Thereafter, FreeGS’s internal optimizer minimizes the currents and hoop and central forces on the PF coils while maintaining the reference equilibrium. Finally, the input configuration is updated with the optimized parameters for equilibria over the ramp-up phase of a burning-plasma operation. FREDA’s whole facility optimization capability, which includes all magnetic field coil systems, blanket, vacuum vessel (VV), first wall, divertor, etc., is under development and out of the scope for this study.

Hassan, Ehab [ORNL] (ORCID:0000000181060301)↗

Electric Power Distribution System Model Simplification Using Segment Substitution

Quasi-static time-series (QSTS) simulation is used to simulate the behavior of distribution systems over long periods of time (typically hours to years). The technique involves repeatedly solving the load-flow problem for a distribution system model and is useful for distributed energy resource (DER) planning. When a QSTS simulation has a small time step and a long duration, the computational burden of the simulation can be a barrier to integration into utility workflows. One way to relieve the computational burden is to simplify the system model. The segment substitution method of simplifying distribution system models introduced in this paper offers model bus reduction of up to 98% with a simplification error as low as 0.2% (0.002 pu voltage). In contrast to existing methods of distribution system model simplification, which rely on topological inspection and linearization, the segment substitution method uses black-box segment data and an assumed simplified topology.

Reiman, Andrew P. (ORCID:0000000302042960)↗

Towards Interactive, Reproducible Analytics at Scale on HPC Systems

The growth in scientific data volumes has resulted in a need to scale up processing and analysis pipelines using High Performance Computing (HPC) systems. These workflows need interactive, reproducible analytics at scale. The Jupyter platform provides core capabilities for interactivity but was not designed for HPC systems. In this paper, we outline our efforts that bring together core technologies based on the Jupyter Platform to create interactive, reproducible analytics at scale on HPC systems. Our work is grounded in a real world science use case-applying geophysical simulations and inversions for imaging the subsurface. Our core platform addresses three key areas of the scientific analysis workflow-reproducibility, scalability, and interactivity. We describe our implemention of a system, using Binder, Science Capsule, and Dask software. We demonstrate the use of this software to run our use case and interactively visualize real-Time streams of HDF5 data.

containers↗

Not just for programmers: How GitHub can accelerate collaborative and reproducible research in ecology and evolution

Abstract Researchers in ecology and evolutionary biology are increasingly dependent on computational code to conduct research. Hence, the use of efficient methods to share, reproduce, and collaborate on code as well as document research is fundamental. GitHub is an online, cloud‐based service that can help researchers track, organize, discuss, share, and collaborate on software and other materials related to research production, including data, code for analyses, and protocols. Despite these benefits, the use of GitHub in ecology and evolution is not widespread. To help researchers in ecology and evolution adopt useful features from GitHub to improve their research workflows, we review 12 practical ways to use the platform. We outline features ranging from low to high technical difficulty, including storing code, managing projects, coding collaboratively, conducting peer review, writing a manuscript, and using automated and continuous integration to streamline analyses. Given that members of a research team may have different technical skills and responsibilities, we describe how the optimal use of GitHub features may vary among members of a research collaboration. As more ecologists and evolutionary biologists establish their workflows using GitHub, the field can continue to push the boundaries of collaborative, transparent, and open research.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Turbo‐charging crop improvement: harnessing multiplex editing for polygenic trait engineering and beyond

Multiplex CRISPR editing has emerged as a transformative platform for plant genome engineering, enabling the simultaneous targeting of multiple genes, regulatory elements, or chromosomal regions. This approach is effective for dissecting gene family functions, addressing genetic redundancy, engineering polygenic traits, and accelerating trait stacking and de novo domestication. Its applications now extend beyond standard gene knockouts to include epigenetic and transcriptional regulation, chromosomal engineering, and transgene‐free editing. These capabilities are advancing crop improvement not only in annual species but also in more complex systems such as polyploids, undomesticated wild relatives, and species with long generation times. At the same time, multiplex editing presents technical challenges, including complex construct design and the need for robust, scalable mutation detection. We discuss current toolkits and recent innovations in vector architecture, such as promoter and scaffold engineering, that streamline workflows and enhance editing efficiency. High‐throughput sequencing technologies, including long‐read platforms, are improving the resolution of complex editing outcomes such as structural rearrangements—often missed by standard genotyping—when targeting repetitive or tandemly spaced loci. To fully realize the potential of multiplex genome engineering, there is growing demand for user‐friendly, synthetic biology‐compatible, and scalable computational workflows for gRNA design, construct assembly, and mutation analysis. Experimentally validated inducible or tissue‐specific promoters are also highly desirable for achieving spatiotemporal control. As these tools continue to evolve, multiplex CRISPR editing is poised to become a foundational technology of next‐generation crop improvement to address challenges in agriculture, sustainability, and climate resilience.

59 BASIC BIOLOGICAL SCIENCES↗

A Framework for Optimal Placement of Rooftop Photovoltaic: Maximizing Solar Production and Operational Cost Savings in Residential Communities

Optimizing the placement of photovoltaic (PV) panels on residential buildings has the potential to significantly increase energy efficiency benefits to both homeowners and communities. Strategic PV placement can lower electricity costs by reducing the electricity fed from the grid during on-peak hours, while maintaining PV panel efficiency in terms of the amount of solar radiation received. In this article, we present a framework that identifies the ideal location of PV panels on residential rooftops. Our framework combines energy and environmental simulation, parametric modeling, and optimization to inform PV placement as it relates to and affects the entire community (in terms of both energy use and financial cost), as well as individual buildings. Ensuring that our framework accounts for shading from nearby buildings, different utility rate structures, and different buildings’ energy demand profiles means that existing communities and future housing developments can be optimized for energy savings and PV efficiency. The framework comprises two workflows, each contributing to optimal PV placement with a unique target: (a) maximizing PV panel efficiency (i.e., solar generation) and (b) minimizing operational energy cost considering utility rate structures for operational energy. We apply our framework to a residential community in Fort Collins, Colorado, to demonstrate the optimal PV placement, considering the two workflow targets. Here, we present our results and illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost.

14 SOLAR ENERGY↗

Toward Accelerating Discovery via Physics-Driven and Interactive Multifidelity Bayesian Optimization

Both computational and experimental material discovery bring forth the challenge of exploring multidimensional and often nondifferentiable parameter spaces, such as phase diagrams of Hamiltonians with multiple interactions, composition spaces of combinatorial libraries, processing spaces, and molecular embedding spaces. Often these systems are expensive or time consuming to evaluate a single instance, and hence classical approaches based on exhaustive grid or random search are too data intensive. This resulted in strong interest toward active learning methods such as Bayesian optimization (BO) where the adaptive exploration occurs based on human learning (discovery) objective. However, classical BO is based on a predefined optimization target, and policies balancing exploration and exploitation are purely data driven. In practical settings, the domain expert can pose prior knowledge of the system in the form of partially known physics laws and exploration policies often vary during the experiment. Here, we propose an interactive workflow building on multifidelity BO (MFBO), starting with classical (data-driven) MFBO, then expand to a proposed structured (physics-driven) structured MFBO (sMFBO), and finally extend it to allow human-in-the-loop interactive interactive MFBO (iMFBO) workflows for adaptive and domain expert aligned exploration. These approaches are demonstrated over highly nonsmooth multifidelity simulation data generated from an Ising model, considering spin–spin interaction as parameter space, lattice sizes as fidelity spaces, and the objective as maximizing heat capacity. Detailed analysis and comparison show the impact of physics knowledge injection and real-time human decisions for improved exploration with increased alignment to ground truth. Here, the associated notebooks allow to reproduce the reported analyses and apply them to other systems.

97 MATHEMATICS AND COMPUTING↗

Materials characterization: Can artificial intelligence be used to address reproducibility challenges?

Material characterization techniques are widely used to characterize the physical and chemical properties of materials at the nanoscale and, thus, play central roles in material scientific discoveries. However, the large and complex datasets generated by these techniques often require significant human effort to interpret and extract meaningful physicochemical insights. Artificial intelligence (AI) techniques such as machine learning (ML) have the potential to improve the efficiency and accuracy of surface analysis by automating data analysis and interpretation. In this perspective paper, we review the current role of AI in surface analysis and discuss its future potential to accelerate discoveries in surface science, materials science, and interface science. We highlight several applications where AI has already been used to analyze surface analysis data, including the identification of crystal structures from XRD data, analysis of XPS spectra for surface composition, and the interpretation of TEM and SEM images for particle morphology and size. We also discuss the challenges and opportunities associated with the integration of AI into surface analysis workflows. These include the need for large and diverse datasets for training ML models, the importance of feature selection and representation, and the potential for ML to enable new insights and discoveries by identifying patterns and relationships in complex datasets. Most importantly, AI analyzed data must not just find the best mathematical description of the data, but it must find the most physical and chemically meaningful results. In addition, the need for reproducibility in scientific research has become increasingly important in recent years. The advancement of AI, including both conventional and the increasing popular deep learning, is showing promise in addressing those challenges by enabling the execution and verification of scientific progress. By training models on large experimental datasets and providing automated analysis and data interpretation, AI can help to ensure that scientific results are reproducible and reliable. Although integration of knowledge and AI models must be considered for the transparency and interpretability of models, the incorporation of AI into the data collection and processing workflow will significantly enhance the efficiency and accuracy of various surface analysis techniques and deepen our understanding at an accelerated pace.

Materials Science↗

Robust methods for automatic image-to-world registration in cone-beam CT interventional guidance

Purpose: Real-time surgical navigation relies on accurate image-to-world registration to align the coordinate systems of the image and patient. Conventional manual registration can present a workflow bottleneck and is prone to manual error and intraoperator variability. This work reports alternative means of automatic image-to-world registration, each method involving an automatic registration marker (ARM) used in conjunction with C-arm cone-beam CT (CBCT). The first involves a Known-Model registration method in which the ARM is a predefined tool, and the second is a Free-Form method in which the ARM is freely configurable. Methods: Studies were performed using a prototype C-arm for CBCT and a surgical tracking system. A simple ARM was designed with markers comprising a tungsten sphere within infrared reflectors to permit detection of markers in both x-ray projections and by an infrared tracker. The Known-Model method exercised a predefined specification of the ARM in combination with 3D-2D registration to estimate the transformation that yields the optimal match between forward projection of the ARM and the measured projection images. The Free-Form method localizes markers individually in projection data by a robust Hough transform approach extended from previous work, backprojected to 3D image coordinates based on C-arm geometric calibration. Image-domain point sets were transformed to world coordinates by rigid-body point-based registration. The robustness and registration accuracy of each method was tested in comparison to manual registration across a range of body sites (head, thorax, and abdomen) of interest in CBCT-guided surgery, including cases with interventional tools in the radiographic scene. Results: The automatic methods exhibited similar target registration error (TRE) and were comparable or superior to manual registration for placement of the ARM within {approx}200 mm of C-arm isocenter. Marker localization in projection data was robust across all anatomical sites, including challenging scenarios involving the presence of interventional tools. The reprojection error of marker localization was independent of the distance of the ARM from isocenter, and the overall TRE was dominated by the configuration of individual fiducials and distance from the target as predicted by theory. The median TRE increased with greater ARM-to-isocenter distance (e.g., for the Free-Form method, TRE increasing from 0.78 mm to 2.04 mm at distances of {approx}75 mm and 370 mm, respectively). The median TRE within {approx}200 mm distance was consistently lower than that of the manual method (TRE = 0.82 mm). Registration performance was independent of anatomical site (head, thorax, and abdomen). The Free-Form method demonstrated a statistically significant improvement (p= 0.0044) in reproducibility compared to manual registration (0.22 mm versus 0.30 mm, respectively). Conclusions: Automatic image-to-world registration methods demonstrate the potential for improved accuracy, reproducibility, and workflow in CBCT-guided procedures. A Free-Form method was shown to exhibit robustness against anatomical site, with comparable or improved TRE compared to manual registration. It was also comparable or superior in performance to a Known-Model method in which the ARM configuration is specified as a predefined tool, thereby allowing configuration of fiducials on the fly or attachment to the patient.

60 APPLIED LIFE SCIENCES↗

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-9A-02: Structured Noise Index as An Automated Quality Control for Nuclear Medicine: A Two Year Experience

Purpose: Flood-field uniformity evaluation is an essential element in the assessment of nuclear medicine (NM) gamma cameras. It serves as the central element of the quality control (QC) program, acquired and analyzed on a daily basis prior to clinical imaging. Uniformity images are traditionally analyzed using pixel value-based metrics which often fail to capture subtle structure and patterns caused by changes in gamma camera performance requiring additional visual inspection which is subjective and time demanding. The goal of this project was to develop and implement a robust QC metrology for NM that is effective in identifying non-uniformity issues, reporting issues in a timely manner for efficient correction prior to clinical involvement, all incorporated into an automated effortless workflow, and to characterize the program over a two year period. Methods: A new quantitative uniformity analysis metric was developed based on 2D noise power spectrum metrology and confirmed based on expert observer visual analysis. The metric, termed Structured Noise Index (SNI) was then integrated into an automated program to analyze, archive, and report on daily NM QC uniformity images. The effectiveness of the program was evaluated over a period of 2 years. Results: The SNI metric successfully identified visually apparent non-uniformities overlooked by the pixel valuebased analysis methods. Implementation of the program has resulted in nonuniformity identification in about 12% of daily flood images. In addition, due to the vigilance of staff response, the percentage of days exceeding trigger value shows a decline over time. Conclusion: The SNI provides a robust quantification of the NM performance of gamma camera uniformity. It operates seamlessly across a fleet of multiple camera models. The automated process provides effective workflow within the NM spectra between physicist, technologist, and clinical engineer. The reliability of this process has made it the preferred platform for NM uniformity analysis.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-18C-06: Initial Experience with Implementing MRI Safety Guidelines for Patients with Pacemakers - Medical Physicist Perspective

Purpose: Several institutions have developed MRI guidelines for patients with MR-unsafe or MR-conditional pacemakers. Here we highlight the role of a medical physicist in implementing these guidelines for non-pacemaker dependent patients. Guidelines: Implementing these guidelines requires involvement from several medical specialties and a strong collaboration with the site MRI supervisor to develop a structured workflow. A medical physicist is required to be present during the scan to supervise the MR scanning and to maintain a safety checklist that ensures: 1) uninterrupted patient communication with the technologist, 2) continuous patient physiologic monitoring (e.g. blood pressure and electrocardiography) by a trained nurse, 3) redundant patient vitals monitoring (e.g. pulse oximetry) due to the possibility of in vivo electrocardiography reading fluctuations during image acquisition. A radiologist is strongly recommended to be available to review the images before patients are discharged from the scanner. Pacemaker MRI should be restricted to 1.5T field strength. The MRI sequences should be optimized by the physicist with regards to: a) SAR: limited to <1.5 W/Kg for MR-unsafe pacemakers in normal operating mode, b) RF exposure time: <30 min, c) Coils: use T/R coils but not restricted to such, d) Artifacts: further optimization of sequences whenever image quality is compromised due to the pacemaker. In particular, cardiac, breast and left-shoulder MRIs are most susceptible to these artifacts. Possible strategies to lower the SAR include: a) BW reduction, 2) echo-train-length reduction, 3) increase TR, 4) decrease number of averages, 5) decrease flip angle, 6) reduce slices and/or a combination of all the options. Conclusion: A medical physicist in collaboration with the MR supervisor plays an important role in the supervision/implementation of safe MR scanning of pacemaker patients. Developing and establishing a workflow has enabled our institution to scan over 30 patients with pacemakers without complications, including 3 cardiac MR exams.

60 APPLIED LIFE SCIENCES↗

MO-A-16A-01: QA Procedures and Metrics: In Search of QA Usability

Radiation therapy has undergone considerable changes in the past two decades with a surge of new technology and treatment delivery methods. The complexity of radiation therapy treatments has increased and there has been increased awareness and publicity about the associated risks. In response, there has been proliferation of guidelines for medical physicists to adopt to ensure that treatments are delivered safely. Task Group recommendations are copious, and clinical physicists' hours are longer, stretched to various degrees between site planning and management, IT support, physics QA, and treatment planning responsibilities.Radiation oncology has many quality control practices in place to ensure the delivery of high-quality, safe treatments. Incident reporting systems have been developed to collect statistics about near miss events at many radiation oncology centers. However, tools are lacking to assess the impact of these various control measures. A recent effort to address this shortcoming is the work of Ford et al (2012) who recently published a methodology enumerating quality control quantification for measuring the effectiveness of safety barriers. Over 4000 near-miss incidents reported from 2 academic radiation oncology clinics were analyzed using quality control quantification, and a profile of the most effective quality control measures (metrics) was identified.There is a critical need to identify a QA metric to help the busy clinical physicists to focus their limited time and resources most effectively in order to minimize or eliminate errors in the radiation treatment delivery processes. In this symposium the usefulness of workflows and QA metrics to assure safe and high quality patient care will be explored.Two presentations will be given:Quality Metrics and Risk Management with High Risk Radiation Oncology ProceduresStrategies and metrics for quality management in the TG-100 Era Learning Objectives: Provide an overview and the need for QA usability metrics: Different cultures/practices affecting the effectiveness of methods and metrics. Show examples of quality assurance workflows, Statistical process control, that monitor the treatment planning and delivery process to identify errors. To learn to identify and prioritize risks and QA procedures in radiation oncology. Try to answer the question: Can a quality assurance program aided by quality assurance metrics help minimize errors and ensure safe treatment delivery. Should such metrics be institution specific.

07 ISOTOPE AND RADIATION SOURCES↗

MO-E-BRD-01: Adapt-A-Thon - Texas Hold’em Invitational

Software tools for image-based adaptive radiotherapy such as deformable image registration, contour propagation and dose mapping have progressed beyond the research setting and are now commercial products available as part of both treatment planning systems and stand-alone applications. These software tools are used together to create clinical workflows to detect, track and evaluate changes in the patient and to accumulate dose. Deviations uncovered in this process are used to guide decisions about replanning/adaptation with the goal of keeping the delivery of prescribed dose “on target” throughout the entire course of radiotherapy. Since the output from one step of the adaptive process is used as an input for another, it is essential to understand and document the uncertainty associated with each of the step and how these uncertainties are propagated. This in turn requires an understanding how the underlying tools work. Unfortunately, important details about the algorithms used to implement these tools are scarce or incomplete, too often for competitive reasons. This is in contrast to the situation involving other basic treatment planning algorithms such as dose calculations, where the medical physics community essentially requires vendors to provide physically important details about their underlying theory and clinical implementation. Vendors should adopt this same level of information sharing when it comes to the tools and techniques for image guided adaptive radiotherapy. The goal of this session is to start this process by inviting vendors and medical physicists to discuss and demonstrate the available tools and describe how they are intended to be used in clinical practice. The format of the session will involve a combination of formal presentations, interactive demonstrations, audience participation and some friendly “Texas style” competition. Learning Objectives: Understand the components of the image-based adaptive radiotherapy process. Understand the how these components are implemented in various commercial systems. Understand the different use cases and workflows currently supported these tools.

60 APPLIED LIFE SCIENCES↗

TU-A-BRF-01: MR Guided Radiation Therapy

In recent years, there has been an increasing interest in the development of new technologies focused on the deeper integration of MR in radiotherapy. The innovations span from image data acquisition and post-processing to clinical implementation of MR-guided RT systems and workflow development. The session is intended to provide a review of the key and most recent advancements. Targeted discussions will cover topics which currently define the concept of MR-guided radiotherapy including a) system commissioning, quality control and safety, b) MR data manipulation for dose computations and treatment simulation, c) quantification/management of organ motion and treatment delivery guidance. Learning Objectives: Understand the concept and specifics of MR-guided radiotherapy; Understand the requirements for system integration in clinical workflow; Become familiar with the proposed strategies for system commissioning, RT planning and delivery guidance.

60 APPLIED LIFE SCIENCES↗

WE-A-19A-01: SRT I: Comparison of SRT Techniques

Within the past several years, the field of radiosurgery has seen numerous technological enhancements, including new dedicated devices for stereotactic delivery, the use of re-locatable frames to facilitate fractionated delivery and the image guided frameless approaches. The goal of this symposium is to compare and contrast competing technologies for cranial SRS/SRT. The symposium will open with a review of the general concept of cranial SRS/SRT procedures as well as describe the key differences from conventional radiotherapy. The speakers will then review each of the delivery technique (Gamma Knife, CyberKnife and Conventional linear accelerator) in turn. The focus of each speaker will be to describe the general workflow of each SRS modality, indications and counterindications for treatment. To compare and contrast different technologies, 2–3 cases examples demonstrating interesting treatment situations and expected outcomes, a sample treatment plan (either live or pre-recorded with live commentary) demonstrating the treatment planning technique, and machine and patient-specific QA required for treatment (if applicable). Additionally, workflows and data describing the use of immobilization devices or tracking/monitoring during SRS/SRT delivery will also be discussed. The session will close with a roundtable discussion of methods to evaluate plan quality, and achievable technical and clinical goals for intracranial SRS. Learning Objectives: Understand the key differences between cranial SRS/SRT and conventional treatments. Review Gamma Knife, CyberKnife and Conventional Linac-based radiosurgery delivery techniques and quality assurance Compare and contrast treatment plans, treatment planning strategy and and quality assurance procedures for each technology. Be able to establish cranial SRS/SRT procedure with optimized quality assurance program for each technology.

60 APPLIED LIFE SCIENCES↗

Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm

Purpose: The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. Methods: The authors describe a DIR based adaptive radiotherapy workflow, using CT and cone-beam CT (CBCT) imaging. The transformations that mapped the anatomy between the two time points were obtained using four different DIR approaches available in NiftyReg. These included a standard unidirectional algorithm and more sophisticated bidirectional ones that encourage or ensure inverse consistency. The forward (CT-to-CBCT) deformation vector fields (DVFs) were used to propagate the CT Hounsfield units and structures to the daily geometry for “dose of the day” calculations, while the backward (CBCT-to-CT) DVFs were used to remap the dose of the day onto the planning CT (pCT). Data from five head and neck patients were used to evaluate the performance of each implementation based on geometrical matching, physical properties of the DVFs, and similarity between warped dose distributions. Geometrical matching was verified in terms of dice similarity coefficient (DSC), distance transform, false positives, and false negatives. The physical properties of the DVFs were assessed calculating the harmonic energy, determinant of the Jacobian, and inverse consistency error of the transformations. Dose distributions were displayed on the pCT dose space and compared using dose difference (DD), distance to dose difference, and dose volume histograms. Results: All the DIR algorithms gave similar results in terms of geometrical matching, with an average DSC of 0.85 ± 0.08, but the underlying properties of the DVFs varied in terms of smoothness and inverse consistency. When comparing the doses warped by different algorithms, we found a root mean square DD of 1.9% ± 0.8% of the prescribed dose (pD) and that an average of 9% ± 4% of voxels within the treated volume failed a 2%pD DD-test (DD{sub 2%-pp}). Larger DD{sub 2%-pp} was found within the high dose gradient (21% ± 6%) and regions where the CBCT quality was poorer (28% ± 9%). The differences when estimating the mean and maximum dose delivered to organs-at-risk were up to 2.0%pD and 2.8%pD, respectively. Conclusions: The authors evaluated several DIR algorithms for CT-to-CBCT registrations. In spite of all methods resulting in comparable geometrical matching, the choice of DIR implementation leads to uncertainties in dose warped, particularly in regions of high gradient and/or poor imaging quality.

60 APPLIED LIFE SCIENCES↗

Automated contouring error detection based on supervised geometric attribute distribution models for radiation therapy: A general strategy

Purpose: One of the most critical steps in radiation therapy treatment is accurate tumor and critical organ-at-risk (OAR) contouring. Both manual and automated contouring processes are prone to errors and to a large degree of inter- and intraobserver variability. These are often due to the limitations of imaging techniques in visualizing human anatomy as well as to inherent anatomical variability among individuals. Physicians/physicists have to reverify all the radiation therapy contours of every patient before using them for treatment planning, which is tedious, laborious, and still not an error-free process. In this study, the authors developed a general strategy based on novel geometric attribute distribution (GAD) models to automatically detect radiation therapy OAR contouring errors and facilitate the current clinical workflow. Methods: Considering the radiation therapy structures’ geometric attributes (centroid, volume, and shape), the spatial relationship of neighboring structures, as well as anatomical similarity of individual contours among patients, the authors established GAD models to characterize the interstructural centroid and volume variations, and the intrastructural shape variations of each individual structure. The GAD models are scalable and deformable, and constrained by their respective principal attribute variations calculated from training sets with verified OAR contours. A new iterative weighted GAD model-fitting algorithm was developed for contouring error detection. Receiver operating characteristic (ROC) analysis was employed in a unique way to optimize the model parameters to satisfy clinical requirements. A total of forty-four head-and-neck patient cases, each of which includes nine critical OAR contours, were utilized to demonstrate the proposed strategy. Twenty-nine out of these forty-four patient cases were utilized to train the inter- and intrastructural GAD models. These training data and the remaining fifteen testing data sets were separately employed to test the effectiveness of the proposed contouring error detection strategy. Results: An evaluation tool was implemented to illustrate how the proposed strategy automatically detects the radiation therapy contouring errors for a given patient and provides 3D graphical visualization of error detection results as well. The contouring error detection results were achieved with an average sensitivity of 0.954/0.906 and an average specificity of 0.901/0.909 on the centroid/volume related contouring errors of all the tested samples. As for the detection results on structural shape related contouring errors, an average sensitivity of 0.816 and an average specificity of 0.94 on all the tested samples were obtained. The promising results indicated the feasibility of the proposed strategy for the detection of contouring errors with low false detection rate. Conclusions: The proposed strategy can reliably identify contouring errors based upon inter- and intrastructural constraints derived from clinically approved contours. It holds great potential for improving the radiation therapy workflow. ROC and box plot analyses allow for analytically tuning of the system parameters to satisfy clinical requirements. Future work will focus on the improvement of strategy reliability by utilizing more training sets and additional geometric attribute constraints.

60 APPLIED LIFE SCIENCES↗