Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Femto-second Laser’s Enabling New Length Scale Fabrications for Rapid Post Irradiation Examination of Materials: Concluding LDRD Project Poster

Mechanical testing campaigns are required to qualify materials for advanced reactor conditions, yet economical and safety limitations restrict the number of standardized mechanical tests that can be performed. Reducing the size of the sample is one approach to addressing these challenges and to accelerating testing. Previous research has shown that smaller mechanical test samples produce higher yield and ultimate stress values compared to values measured from standard sample sizes: the “smaller is stronger” effect. Specimens used in accelerated material testing campaigns must reflect bulk material performance to enable engineering scale material property measurement. The objective of this research project was to determine if engineering scale mechanical behavior—the yield stress—could be measured with micro-tensile test samples smaller than traditional standard testing geometries. The relationship between yield stress and sample size was explored with two different nuclear-relevant structural materials: Zircaloy-4 and tungsten. Mechanical testing of both metals demonstrated decreasing yield stress values with increasing sample gauge size across three different sizes. Yield stress values from the largest gauge size, fabricated with a femto-second laser ablation system, approach bulk material yield stress values reported in published literature. Preliminary analysis of the tungsten samples indicates the yield stress value depends on the grain characteristics within the gauge section, in addition to the gauge size. Accompanying modeling efforts, including response surface generation and crystal plasticity approaches, further demonstrated that the size of the sample gauge section alone cannot explain the change in yield stress values.

36 MATERIALS SCIENCE↗

A 200 MHz 35 MW Multiple Beam Klystron for Accelerator Applications Final Report

Calabazas Creek Research, Inc. (CCR) performed initial development of a compact and reliable 35 MW, multiple beam klystron (MBK) at 200 MHz with a pulse length of 0.125 ms and a 30 Hz repetition rate. The device was targeted for acceleration and ionization cooling of a muon collider, but there are several other potential applications in this frequency range. The klystron uses multiple beams propagating in individual beam tunnels to reduce space charge and allow reduction in the accelerating voltage. This allows a significant reduction in length over a single beam source. More importantly this allows more efficient and less expensive power supplies. At 200 MHz, the interaction circuit for a single beam klystron would be more than six meters long to obtain 50% efficiency and 50 dB gain. This would require a beam voltage of approximately 400 kV and current of 251 A for a microperveance of 1.0. For an eight beam MBK with the same beam perveance, a three meter long interaction circuit achieves the same power and gain. Each beam operates at 142 kV and 70A. The Phase I demonstrated that this device could be fabricated with funding available in a Phase II program and could achieve the program specifications.

43 PARTICLE ACCELERATORS↗

Effect of Catalyst and Catalyst Layer Composition on Catalyst Support Durability

Polymer electrolyte membrane fuel cells (PEMFCs) are efficient, zero-emission engines for the automotive sector. However, cost and durability are major barriers for the commercialization of PEMFCs. Degradation of the carbon support in the cathode catalyst layer due to high potential excursions caused by unmitigated events like H 2 starvation, or start-up/shutdown are still a major durability issue in PEMFCs. Catalyst support durability was studied by accelerated stress tests (ASTs) that included repeated potential cycling from 1.0 to 1.5 V. The effect of catalyst layer composition on carbon corrosion was studied using membrane electrode assemblies with different catalysts (Pt, PtCo), catalyst composition (catalyst wt.%, supports), ionomer composition (loading, and equivalent weights). The corrosion of the carbon support is similar between Pt and PtCo catalysts. However, the performance degradation rate is higher for the alloy catalysts due to differences in catalyst particle size and the transition metal’s leaching accelerating the performance degradation. The carbon loss is lower for catalysts with lower initial carbon loading (or higher catalyst wt.%), which is better for durability. However, the cumulative loss of carbon is identical for electrodes with the same catalyst support irrespective of catalyst and ionomer composition in the catalyst layer.

25 ENERGY STORAGE↗

Parallel 3-D method of characteristics in MPACT

A new parallel 3-D MOC kernel has been developed and implemented in MPACT which makes use of the modular ray tracing technique to reduce computational requirements and to facilitate parallel decomposition. The parallel model makes use of both distributed and shared memory parallelism which are implemented with the MPI and OpenMP standards, respectively. The kernel is capable of parallel decomposition of problems in space, angle, and by characteristic rays up to 0(104) processors. Initial verification of the parallel 3-D MOC kernel was performed using the Takeda 3-D transport benchmark problems. The eigenvalues computed by MPACT are within the statistical uncertainty of the benchmark reference and agree well with the averages of other participants. The MPACT k{sub eff} differs from the benchmark results for rodded and un-rodded cases by 11 and -40 pcm, respectively. The calculations were performed for various numbers of processors and parallel decompositions up to 15625 processors; all producing the same result at convergence. The parallel efficiency of the worst case was 60%, while very good efficiency (>95%) was observed for cases using 500 processors. The overall run time for the 500 processor case was 231 seconds and 19 seconds for the case with 15625 processors. Ongoing work is focused on developing theoretical performance models and the implementation of acceleration techniques to minimize the number of iterations to converge. (authors)

97 MATHEMATICS AND COMPUTING↗

Self-optimized construction of transition rate matrices from accelerated atomistic simulations with Bayesian uncertainty quantification

Here, a massively parallel method to build large transition rate matrices from temperature-accelerated molecular dynamics trajectories is presented. Bayesian Markov model analysis is used to estimate the expected residence time in the known state space, providing crucial uncertainty quantification for higher-scale simulation schemes such as kinetic Monte Carlo or cluster dynamics. The estimators are additionally used to optimize where exploration is performed and the degree of temperature acceleration on the fly, giving an autonomous, optimal procedure to explore the state space of complex systems. The method is tested against exactly solvable models and used to explore the dynamics of C15 interstitial defects in iron. Our uncertainty quantification scheme allows for accurate modeling of the evolution of these defects over timescales of several seconds.

36 MATERIALS SCIENCE↗

Improvement of accelerator of negative ion source on the Large Helical Device

To improve the performance of negative-ion based neutral beam injection on the Large Helical Device, the accelerator was modified on the basis of numerical investigations. A field limiting ring was installed on the upper side of a grounded grid (GG) support and a multi-slot GG was adopted instead of a multi-aperture GG. As a result, the voltage holding capability is improved and the heat load on the GG decreases by 40%. In addition, the arc efficiency is improved significantly only by replacing the GG.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerated tert -butyloxycarbonyl deprotection of amines in microdroplets produced by a pneumatic spray

Protection and deprotection of organic compounds in multistep reactions using functional groups such as tert-butoxycarbonyl (Boc), is widely performed in synthetic organic chemistry. Reaction rate acceleration studies in spray-based ionization methods (electrosonic spray, paper spray, nanospray) have become increasingly common. In this report, we demonstrate reaction rate acceleration of Boc deprotection using easy ambient sonic-spray ionization (EASI), a pneumatic technique which does not involve an applied voltage, in a teaching laboratory setting. The goal of this laboratory exercise was to explore acceleration in a previously unexplored spray-based reaction, while emphasizing in a pedagogic setting the importance of protecting groups for multistep synthesis. Rate acceleration factors of more than an order of magnitude were observed in the uncharged micron-sized droplets generated by EASI. The effect of reaction conditions on reaction acceleration was examined including changes in the type of acid, reagent concentration ratios and syringe pump flow rates. Student knowledge was assessed by pre-laboratory assignments, post-laboratory reports and oral interviews.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A simple gating technique for high-average-current photo-injectors

This paper describes a simple method that substantially improves the production of gated electron bunch trains by totally suppressing undesired background photoemission between the trains. A device has been designed and tested with a drive laser for proof-of-principle demonstration. The predicted functionality and performance are verified on an Energy-Recovery-Linac (ERL) electron accelerator. The method can find applications whenever the laser pulse repetition rate and length need to be tailored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetohydrodynamic Augmented Propulsion Experiment

A fundamental obstacle to routine space access is the specific energy limitations associated with chemical fuels. In the case of vertical take-off, the high thrust needed for vertical liftoff and acceleration to orbit translates into power levels in the 10 GW range. Furthermore, useful payload mass fractions are possible only if the exhaust particle energy (i.e., exhaust velocity) is much greater than that available with traditional chemical propulsion. The electronic binding energy released by the best chemical reactions (e.g., LOX/LH2 for example, is less than 2 eV per product molecule (approx. 1.8 eV per H2O molecule), which translates into particle velocities less than 5 km/s. Useful payload fractions, however, will require exhaust velocities exceeding 15 km/s (i.e., particle energies greater than 20 eV). As an added challenge, the envisioned hypothetical RLV (reusable launch vehicle) should accomplish these amazing performance feats while providing relatively low acceleration levels to orbit (2-3g maximum). From such fundamental considerations, it is painfully obvious that planned and current RLV solutions based on chemical fuels alone represent only a temporary solution and can only result in minor gains, at best. What is truly needed is a revolutionary approach that will dramatically reduce the amount of fuel and size of the launch vehicle. This implies the need for new compact high-power energy sources as well as advanced accelerator technologies for increasing engine exhaust velocity. Electromagnetic acceleration techniques are of immense interest since they can be used to circumvent the thermal limits associated with conventional propulsion systems. This paper describes the Magnetohydrodynamic Augmented Propulsion Experiment (MAPX) being undertaken at NASA Marshall Space Flight Center (MSFC). In this experiment, a 1-MW arc heater is being used as a feeder for a 1-MW magnetohydrodynamic (MHD) accelerator. The purpose of the experiment is to demonstrate that an MHD accelerator can be an effective augmentation system for increasing engine exhaust velocity. More specifically, the experiment is intended to show that electromagnetic effects are effective at producing flow acceleration whereas electrothermal effects do not cause unacceptable heating of the working fluid. The MHD accelerator was designed as an externally diagonalized segmented Faraday channel, which will be inserted into an existing 2-tesla electromagnet. This allows the external power to be connected through two terminals thereby minimizing the complexity and cost associated with powering each segment independently. The design of the accelerator and other components in the flow path has been completed and fabrication activities are underway. This paper provides a full description of MAPX including performance analysis, design, and test plans, and current status.

Litchford, Ron J.↗

Domain-specific text embedding model for accelerator physics

Accelerator physics presents unique challenges for natural language processing (NLP) due to its specialized terminology and complex concepts. A key component in overcoming these challenges is the development of robust text embedding models that transform textual data into dense vector representations, facilitating efficient information retrieval and semantic understanding. In this work, we introduce AccPhysBERT, a sentence embedding model fine-tuned specifically for accelerator physics. Our model demonstrates superior performance across a range of downstream NLP tasks, surpassing existing models in capturing the domain-specific nuances of the field. We further showcase its practical applications, including semantic paper-reviewer matching and integration into retrieval-augmented generation systems, highlighting its potential to enhance information retrieval and knowledge discovery in accelerator physics. Published by the American Physical Society 2025

Hellert, Thorsten (ORCID:0000000227970926)↗

Review of R&D at DESY on ingot niobium for accelerators

An R&D program at DESY exploring the potential of the production of 1.3 GHz TESLA shape cavities from large grain or ingot niobium material has been carried out as a feasibility study for using ingot niobium material for the European X-ray Free-Electron Laser project. The most important issues like feasibility of the fabrication of niobium discs from ingots, material properties, cavity fabrication, treatment, and finally the cryogenic radiofrequency (RF) performance of the cavity in the accelerator modules are presented and discussed. At least 25% higher intrinsic quality factor comparing to conventional fine-grain niobium and high accelerating gradient of up to 45 MV/m have been demonstrated during the cryogenic RF tests both in the vertical cryostats and in a completely assembled accelerating cryo-module.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Accelerated Aging Test for Plastic Scintillator Gamma Ray Detectors

Polyvinyl toluene (PVT) and polystyrene (PS), collectively referred to as “plastic scintillator,” are synthetic polymer materials used to detect gamma radiation, and are commonly used in instrumentation. Recent studies have revealed that plastic scintillator undergoes an environmentally related material degradation that adversely affects performance under certain conditions and histories. A significant decrease in gamma ray sensitivity has been seen in some detectors in systems as they age. The degradation of sensitivity of plastic scintillator over time is due to a variety of factors, and the term “aging” is used to encompass all factors. Some plastic scintillator samples show no aging effects (no significant change in sensitivity over more than 10 years), while others show severe aging (significant change in sensitivity in less than 5 years). Aging effects arise from weather (variations in heat and humidity), chemical exposure, mechanical stress, light exposure, and loss of volatile components. The damage produced by these various causes can be cumulative, causing observable damage to increase over time. Damage may be reversible up to some point, but becomes permanent under some conditions. It has been demonstrated that exposure of plastic scintillator in an environmental chamber to 30 days of high temperature and humidity (90% relative humidity and 55°C) followed by a single cycle to cold temperature (-30°C) will produce severe fogging in all PVT samples. This thermal cycle will be referred to as the “Accelerated Aging Test.” This document describes the procedure for performing this Accelerated Aging Test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An approach to combine neutron and ion irradiation data to accelerate material qualification for nuclear reactors

Next-generation nuclear power plants are generally characterized by higher operating temperatures, increased neutron fluences and energies, and distinct corrosive coolant environments versus the existing light water reactor fleet. Whether using existing materials in new environments, newly developed materials tailored for these environments, or new manufacturing methods, the traditional decades-long approach for materials qualification does not facilitate rapid deployment. Ion irradiation has demonstrated success in reproducing material microstructure and select property evolution resulting from neutron irradiation with three to four orders of magnitude reduction in time and cost, making it an ideal candidate for accelerated irradiation testing. Because microstructure has a large impact on bulk material properties, limited neutron irradiation data at lower damage levels can in principle be combined with accelerated ion testing results and modeling and simulation to form an accurate prediction of microstructure evolution and select properties under different neutron irradiation conditions and at higher damage levels. The objective of this work is to present a conceptual framework of specific steps to fulfill several technical challenges associated with qualifying materials for performance in radiation environments on an accelerated time frame. A brief review of the regulatory landscape for materials in nuclear environments is presented, followed by additional overviews to understand the current state of the art for correlation of materials properties across radiation environments using experimental and computational methodologies. Finally, the roles of academia, national laboratories, and industry in the advancement of this accelerated materials qualification framework are discussed as a path forward, with possible case studies presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Interaction of semicircular canal stimulation with carotid baroreceptor reflex control of heart rate

The carotid-cardiac baroreflex contributes to the prediction of orthostatic tolerance; experimental attenuation of the reflex response leads to orthostatic hypotension in humans and animals. Anecdotal observations indicate that rotational head movements about the vertical axis of the body can also induce orthostatic bradycardia and hypotension through increased parasympathetic activity. We therefore measured the chronotropic response to carotid baroreceptor stimulation in 12 men during varying conditions of vestibulo-oculomotor stimulation to test the hypothesis that stimulation of the semicircular canals associated with head movements in the yaw plane inhibits cardioacceleration through a vagally mediated baroreflex. Carotid-cardiac baroreflex response was assessed by plotting R-R intervals (ms) at each of 8 neck pressure steps with their respective carotid distending pressures (mmHg). Calculated baroreflex gain (maximal slope of the stimulus-response relationship) was measured under 4 experimental conditions: 1) sinusoidal whole-body yaw rotation of the subject in the dark without visual fixation (combined vestibular-oculomotor stimulation); 2) yaw oscillation of the subject while tracking a small head-fixed light moving with the subject (vestibular stimulation without eye movements); 3) subject stationary while fixating on a small light oscillating in yaw at the same frequency, peak acceleration, and velocity as the chair (eye movements without vestibular stimulation); and 4) subject stationary in the dark (no eye or head motion). Head motion alone and with eye movement reduced baseline baroreflex responsiveness to the same stimulus by 30%. Inhibition of cardioacceleration during rotational head movements may have significant impact on functional performance in aerospace environments, particularly in high-performance aircraft pilots during high angular acceleration in aerial combat maneuvers or in astronauts upon return from spaceflight who already have attenuated baroreflex functions.

Review, Tutorial↗

General solutions of optimum problems in nonstationary flight

A general method concerning optimum problems in nonstationary flight is developed and discussed. Best flight techniques are determined for the following conditions: climb with minimum time, climb with minimum fuel consumption, steepest climb, descending and gliding flight with maximum time or with maximum distance. Optimum distributions of speed with altitude are derived assuming constant airplane weight and neglecting curvatures and squares of path inclination in the projection of the equation of motion on the normal to the flight path. The results of this paper differ from the well-known results obtained by neglecting accelerations with one exception, namely the case of gliding with maximum range. The paper is concluded with criticisms and remarks concerning the physical nature of the solutions and their usefulness for practical applications.

AIRPLANES - PERFORMANCE↗

On the Future High Energy Colliders

High energy particle colliders have been in the forefront of particle physics for more than three decades. At present the near term US, European and international strategies of the particle physics community are centered on full exploitation of the physics potential of the Large Hadron Collider (LHC) through its high-luminosity upgrade (HL-LHC). A number of the next generation collider facilities have been proposed and are currently under consideration for the medium and far-future of accelerator-based high energy physics. In this paper we offer a uniform approach to evaluation of various accelerators based on the feasibility of their energy reach, performance potential and cost range.

43 PARTICLE ACCELERATORS↗

Gamma-Beta-Neutron Detectors Set-Up at ALTO

A multi detection system consisted of 90 {sup 3}He counters, gamma detector and beta detector has been installed at beamline of the accelerator complex ALTO. The system allows performing direct measurements of probability of delayed neutron emission from spontaneous fission fragments. A trial experiment was carried out to test the detection system created.

43 PARTICLE ACCELERATORS↗