Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Global Feedback Simulator

GFS is a simulation engine that is used for the characterization of Accelerator performance parameters based on the machine layout, configuration and noise sources. It combines extensively tested Feedback models with a longitudinal phase space tracking simulator along with the interaction between the two via beam-based feedback using a computationally efficient simulation engine. The models include beam instrumentation, considerations on loop delays for in both the R and beam-based feedback loops, as well as the ability to inject noise (both correlated and uncorrelated) at different points of the machine including a full characterization of the electron gun performance parameters.

Doolittle, Lawrence↗

Criteria for admissible values of smooth aberrations for nondiffractive laser beams

We have derived analytical expressions, verified by the methods of numerical simulation, to evaluate the angular divergence of nondiffractive laser beams containing smooth aberrations, i.e., spherical defocusing, astigmatism and toroid. Using these expressions we have formulated the criteria for admissible values of smooth aberrations. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

1-D Van der Waals Foams Heated by Ion Beam Energy Deposition

One dimensional simulations of various initial average density aluminum foams (modeled as slabs of solid metal separated by low density regions) heated by volumetric energy deposition are conducted with a Lagrangian hydrodynamics code using a van der Waals equation of tate (EOS). The resulting behavior is studied to facilitate the design of future warm dense matter (WDM) experiments at LBNL. In the simulations the energy deposition ranges from 10 to 30 kJ/g and from 0.075 to 4.0 ns total pulse length, resulting in temperatures from approximately 1 o 4 eV. We study peak pressures and temperatures in the foams, expansion velocity, and the phase evolution. Five relevant time scales in the problem are identified. Additionally, we present a method for characterizing the level of inhomogeneity in a foam target as it is heated and the time it takes for a foam to homogenize.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

One-dimensional particle simulation of the filamentation instability: Electrostatic field driven by the magnetic pressure gradient force

Two counterpropagating cool and equally dense electron beams are modeled with particle-in-cell simulations. The electron beam filamentation instability is examined in one spatial dimension, which is an approximation for a quasiplanar filament boundary. It is confirmed that the force on the electrons imposed by the electrostatic field, which develops during the nonlinear stage of the instability, oscillates around a mean value that equals the magnetic pressure gradient force. The forces acting on the electrons due to the electrostatic and the magnetic field have a similar strength. The electrostatic field reduces the confining force close to the stable equilibrium of each filament and increases it farther away, limiting the peak density. The confining time-averaged total potential permits an overlap of current filaments with an opposite flow direction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing Normal Tissue Sparing in Ion Therapy Using Calculated Isoeffective Dose for Ion Selection

Purpose: To investigate how the selection of ion type affects the calculated isoeffective dose to the surrounding normal tissue as a function of both normal tissue and target tissue {alpha}/{beta} ratios. Methods and Materials: A microdosimetric biologic dose model was incorporated into a Geant4 simulation of parallel opposed beams of protons, helium, lithium, beryllium, carbon, and neon ions. The beams were constructed to give a homogeneous isoeffective dose to a volume in the center of a water phantom for target tissues covering a range of cobalt equivalent {alpha}/{beta} ratios of 1-20 Gy. Concomitant normal tissue isoeffective doses in the plateau of the ion beam were then compared for different ions across the range of normal tissue and target tissue radiosensitivities for a fixed isoeffective dose to the target tissue. Results: The ion type yielding the optimal normal tissue sparing was highly dependent on the {alpha}/{beta} ratio of both the normal and the target tissue. For carbon ions, the calculated isoeffective dose to normal tissue at a 5-cm depth varied by almost a factor of 5, depending on the {alpha}/{beta} ratios of the normal and target tissue. This ranges from a factor of 2 less than the isoeffective dose of a similar proton treatment to a factor of 2 greater. Conclusions: No single ion is optimal for all treatment scenarios. The heavier ions are superior in cases in which the {alpha}/{beta} ratio of the target tissue is low and the {alpha}/{beta} ratio of normal tissue is high, and protons are superior in the opposite circumstances. Lithium and beryllium appear to offer dose advantages similar to carbon, with a considerably lower normal tissue dose when the {alpha}/{beta} ratio in the target tissue is high and the {alpha}/{beta} ratio in the normal tissue is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser irradiance scaling in polar direct drive implosions on the National Ignition Facility

We report polar-direct-drive experiments conducted at the National Ignition Facility [E. I. Moses, Fusion Sci. Technol. 54, 361 (2008)] performed at laser irradiance between 1 and 2×10 15 W/cm 2 exhibit increased hard x-ray emission, decreased neutron yield, and reduced areal density as the irradiance is increased. Experimental x-ray images at the higher irradiances show x-ray emission at the equator, as well as degraded symmetry, that is not predicted in hydrodynamic simulations using flux-limited energy transport, but that appear when non-local electron transport together with a model to account for cross beam energy transfer (CBET) is utilized. The reduction in laser power for equatorial beams required in the simulations to reproduce the effects of CBET on the observed symmetry also reproduces the yield degradation consistent with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral Galerkin solver for intense beam Vlasov equilibria in nonlinear constant focusing channels

Here a numerical method is described for producing stationary solutions of the Vlasov-Poisson system describing a relativistic charged-particle beam in a constant focusing accelerator channel, confined transversely by a general (linear or nonlinear) focusing potential. The method utilizes a variant of the spectral Galerkin algorithm to solve a nonlinear partial differential equation (PDE) in two degrees of freedom for the beam space charge potential in equilibrium. Numerical convergence with an increasing number of computed spectral modes is investigated for several benchmark problems. Preservation of the stationary phase space density is verified using a strongly nonlinear focusing channel based on the Integrable Optics Test Accelerator at Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS↗

Platform for Integrated Land use And Transportation Experiments and Simulation (PILATES) v1.0

PILATES allows for flexibly and at-scale coupling of multiple models to allow for multi-scale and multi-resolution simulation of regional-scale transport networks. In particular, it couples the MATSim-derived transportation modeling framework for Behavior, Energy, Autonomy and Mobility (BEAM) with other models operating at different time scales. Rather than tightly coupling supply and demand models using shared agents and memory within the same software process, PILATES orchestrates different model runs in a containerized framework. This structure requires passing information from the demand models to BEAM in the format of a synthetic population and agent plans, and from BEAM to the demand models in terms or origin/destination tables (also known as "skims"). This allows it to take advantage of the behavioral sophistication of existing activity-based models as well as the reinforcement learning structure of MATSim replanning and adopted by BEAM, in a way that requires minimal changes to existing models. It also takes advantage of the computational performance of BEAM, which allows for simulations with millions of agents to complete in reasonable time as well as allowing for detailed mechanistic simulation of the operation of on-demand modes.

Needell, Zachary↗

Micromachined silicon cantilever beam accelerometer incorporating an integrated optical waveguide

A micromachined cantilever beam accelerometer is described in which beam deflection is determined optically. A diving board structure is anisotropically etched into a silicon wafer. This diving board structure is patterned from the wafer backside so as to leave a small gap between the tip of the diving board and the opposite fixed edge on the front side of the wafer. In order to sense a realistic range of accelerations, a foot mass incorporated onto the end of the beam is found to provide design flexibility. A silicon nitride optical waveguide is then deposited by low pressure chemical vapor deposition (LPCVD) onto the sample. Beam deflection is measured by the decrease of light coupled across the gap between the waveguide sections. In order to investigate sensor response and simulate deflection of the beam, we utilized a separate beam and waveguide section which could be displaced from one another in a precisely controlled manner. Measurements were performed on samples with gaps of 4.0, 6.0, and 8.0 micron and the variation of the fraction of light coupled across the gap as a function of displacement and gap spacing was found to agree with overlap integral calculations.

Burcham, Kevin E.↗

Energy Spread of the Proton Beam in the Fermilab Booster at its Injection Energy

We have measured the energy spread of the Booster beam at its injection energy of 400 MeV by three different methods: (1) creating a notch of about 40 nsec wide in the beam immediately after multiple turn injection and measuring the slippage time required for high and low momentum particles for a grazing touch in line-charge distribution, (2) injecting partial turn beam and letting it to debunch, and (3) comparing the beam profile monitor data with predictions from MAD simulations for the 400 MeV injection beam line. The measurements are repeated under varieties of conditions of rf systems in the ring and in the beam transfer line.

43 PARTICLE ACCELERATORS↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range

Purpose: Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to photon energies between 80 and 150 kVp. The performance of PSDs is also investigated to determine their potential usefulness in the diagnostic energy range. Methods: A 1-mm-diameter, 10-mm-long PSD was irradiated by a Therapax SXT 150 unit using five different beam qualities made of tube potentials ranging from 80 to 150 kVp and filtration thickness ranging from 0.8 to 0.2 mmAl + 1.0 mmCu. The light emitted by the detector was collected using an 8-m-long optical fiber and a polychromatic photodiode, which converted the scintillation photons to an electrical current. The PSD response was compared with the reference free air dose rate measured with a calibrated Farmer NE2571 ionization chamber. PSD measurements were corrected using spectra-weighted corrections, accounting for mass energy-absorption coefficient differences between the sensitive volumes of the ionization chamber and the PSD, as suggested by large cavity theory (LCT). Beam spectra were obtained from x-ray simulation software and validated experimentally using a CdTe spectrometer. Correction factors were also obtained using Monte Carlo (MC) simulations. Percent depth dose (PDD) measurements were compensated for beam hardening using the LCT correction method. These PDD measurements were compared with uncorrected PSD data, PDD measurements obtained using Gafchromic films, Monte Carlo simulations, and previous data. Results: For each beam quality used, the authors observed an increase of the energy response with effective energy when no correction was applied to the PSD response. Using the LCT correction, the PSD response was almost energy independent, with a residual 2.1% coefficient of variation (COV) over the 80-150-kVp energy range. Monte Carlo corrections reduced the COV to 1.4% over this energy range. All PDD measurements were in good agreement with one another except for the uncorrected PSD data, in which an over-response was observed with depth (13% at 10 cm with a 100 kVp beam), showing that beam hardening had a non-negligible effect on the PSD response. A correction based on LCT compensated very well for this effect, reducing the over-response to 3%.Conclusion: In the diagnostic energy range, PSDs show high-energy dependence, which can be corrected using spectra-weighted mass energy-absorption coefficients, showing no considerable sign of quenching between these energies. Correction factors obtained by Monte Carlo simulations confirm that the approximations made by LCT corrections are valid. Thus, PSDs could be useful for real-time dosimetry in radiology applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPS large array simulation

The computer programming efforts were directed primarily to beam pattern analysis. The computer programs used for simulation provide: verification of the reference design; definition of feasible departures such as quantized distributions; the study of far-out sidelobe roll-off characteristics; the analysis of errors and failures; illumination function analysis to develop beam patterns for efficient collection; and beam shaping synthesis to meet environmental constraints.

Rathjen, S.↗

Electron cloud considerations for HIF drivers

Here, we review some previous results on electron-cloud dynamics and accumulation and the impact of electron clouds on ion beam dynamics, and assess these in the context of a magnetic-quadrupole-based heavy-ion fusion driver. We present a new analysis which exploits analytic solution of linearized envelope equations between accelerating gaps to derive a set of mapping equations which we use to extrapolate from previously obtained particle-simulation results for a beam transport system to an HIF driver.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A button - type beam position monitor design for TARLA facility

Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) facility is proposed as an IR FEL and Bremsstrahlung facility as the first facility of Turkish Accelerator Center (TAC). TARLA is essentially proposed to generate oscillator mode FEL in 3-250 microns wavelengths range, will consist of normal conducting injector system with 250 keV beam energy, two superconducting RF accelerating modules in order to accelerate the beam 15-40 MeV. The TARLA facility is expected to provide two modes, Continuous wave (CW) and pulsed mode. Longitudinal electron bunch length will be changed between 1 and 10 ps. The bunch charge will be limited by 77pC. The design of the Button-type Beam Position Monitor for TARLA IR FEL is studied to operate in 1.3 GHz. Mechanical antenna design and simulations are completed considering electron beam parameters of TARLA. Ansoft HFSS and CST Particle Studio is used to compare with results of simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relative phase interactions of two copropagating laser beams in underdense plasmas at different intensities and spot sizes

The mutual interactions of two copropagating laser beams at a relative phase are studied using a two-dimensional fluid code. The interactions are investigated in underdense plasma at selected beam configurations and beam parameters for two separate nonlinearities, i.e., the ponderomotive and the relativistic nonlinearity. The selected beam configurations are introduced by different initial transverse spot size perturbations (finite and infinite) and different initial transversal intensity distributions (nonuniform and uniform) over those spot sizes and the selected beam parameters are given by different initial beam intensities relevant to each nonlinearity. In the ponderomotive nonlinearity, simulation results show that no mutual interactions are demonstrated between the copropagating beams regardless of the initial beam configurations and parameters. In nonlinear relativistic simulations, the mutual interactions between the beams are clearly observed, a mutual repulsion is formed in the presence of initial intensities that are nonuniformly distributed over finite spot sizes, and an effective strongly modulated mutual attraction takes places in the presence of initial intensities that are uniformly distributed over infinite spot sizes. Moreover, it is found in these simulations that increasing the initial beam intensities improves the attraction properties between the copropagationg beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Irradiation Accelerated Corrosion of Stainless Steel and Ferritic-Martensitic Steel in Simulated Primary Water

Austenitic stainless steel, and ferritic-martensitic steel were irradiated with a proton beam while simultaneously exposed to simulated PWR primary water. Samples were exposed for 4-72 hr in 320°C water with 3 wppm hydrogen while simultaneously irradiated at surface dose rates from 400-4000 kGy/s (4x10-7 to 7x10-6 dpa/s). After exposure, samples were characterized with TEM, EDS, and Raman spectroscopy to determine the effects of radiation on the growth and stability of the oxide films. Samples which were irradiated during exposure had thinner inner oxides compared to unirradiated samples. Irradiated samples also had hematite on their surfaces, while unirradiated samples did not, indicating an increase in corrosion potential due to irradiation. Sample regions which were not irradiated but were exposed to the flow of irradiated water were similar to directly irradiated regions, suggesting that water radiolysis is the mechanism primarily responsible for the observed effects.

Stainless Steel, ferritic-martensitic steel, radia↗