Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Decay Curve Correction Analysis Report

The decay curve analysis that is done on the short-lived radionuclide gas samples is used to differentiate between gaseous radionuclides that have the same characteristic gamma decay energy, 511 kiloelectron-volts (keV). A sample of stack gas is isolated and the total counts in the 511 keV peak are counted repeatedly in 10-second intervals to evaluate the decay rate of the sample over time. Analysis of this decay data required a series of steps. First, a raw data report is generated by the gamma acquisition system, based on an analysis template within the acquisition software. The data report file was then loaded into Microsoft Word, and a macro was used to perform minor formatting (remove colons and insert tabs between data columns) to allow analysis within Excel. The file is then saved as a text file at this point. The text file is then uploaded into Excel and a series of macros are used to add labels, calculate radioactive decay constants, and analyze the gamma decay data using linear regression techniques. The analysis template has been used since 1998 for stack 53000303 (TA-53, building 0003, exhaust stack 03) and 2000 for stack 53000702. The overall process, including the gamma report format and the macros used in Word and Excel for processing the report, had remained unchanged until 2015. In October of 2015, staff made a change to the report template in the gamma acquisition software which resulted in an error in the calculations later performed by the Excel macro. This error was not caught until a more in-depth review of the analysis took place regarding 2020 data. This report covers a much more complete review of the issue that occurred regarding the decay curve analysis, a review of the calculations completed to correct the issue, a review of the updated decay curve analysis process, and recommendations for moving forward.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection of Isotopes in Urban Source Search Gamma Spectra Using Hopfield Neural Network

Source search campaigns involve the measurement of consecutive background gamma-ray spectra obtained with a mobile detector-spectrometer, such as tellurium-doped sodium iodide NaI(Tl) scintillator detector-spectrometer. Counts are measured with NaI(Tl) detector in short acquisition intervals, such as one second. Detection of isotopes in search data is challenging because of the low signal-to-noise ratio (S/N) of the spectral lines and highly varying background due to naturally occurring radioactive material (NORM). In this work, we investigate the performance of the detection of orphan Cs-137, Am-241, and I-131 isotopes in a gamma ray data set obtained in a search survey. Isotopic detection is performed with a Hopfield Neural Network (HNN), which implements an auto-associative memory by matching incoming measurements to the closest one of its memory-stored signature patterns. HNN is trained on examples of spectra of calibrated isotopic sources with well-resolved spectral lines. During testing, HNN processes spectra with partially complete or distorted isotopic lines. The performance of the HNN detection algorithm is benchmarked with Precision, Recall, and F1 scores. Test results demonstrate the potential of HNN to detect the isotope of interest with high accuracy (F1 > 90%) for all isotopes in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Parameters and Objectives of a High-­Resolution X-­ray Imaging Crystal Spectrometer for the Large Helical Device (LHD)

A high-resolution X-ray imaging crystal spectrometer, whose instrumental concept was thoroughly tested on NSTX and Alcator C-Mod, is presently being designed for LHD. The instrument will record spatially resolved spectra of helium-like Ar16+ and provide ion temperature profiles with spatial and temporal resolutions of 1 cm and > 10 ms which are obtained by a tomographic inversion of the spectral data, using the stellarator equilibrium reconstruction codes, STELLOPT and PIES. Since the spectrometer will be equipped with radiation hardened, high count rate, PILATUS detectors,, it is expected to be operational for all experimental conditions on LHD, which include plasmas of high density and plasmas with auxiliary RF and neutral beam heating. The special design features required by the magnetic field structure at LHD will be described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alternative Fueling Station Locations

Alternative fueling stations are located throughout the United States and Canada, and their availability continues to grow. The Alternative Fuels Data Center (AFDC) maintains a website where you can find alternative fueling stations near you or on a route, obtain counts of alternative fueling stations by state, view maps, and more. The most recent dataset available for download here provides a "snapshot" of the alternative fueling station information for compressed natural gas (CNG), ethanol (E85), propane/liquefied petroleum gas (LPG), biodiesel (B20 and above), electric vehicle charging, hydrogen, and liquefied natural gas (LNG), as of July 29, 2021.

alt fuel↗

Capturing Maize Stand Heterogeneity Across Yield-Stability Zones Using Unmanned Aerial Vehicles (UAV)

Despite the new equipment capabilities, uneven crop stands are still common occurrences in crop fields, mainly due to spatial heterogeneity in soil conditions, seedling mortality due to herbivore predation and disease, or human error. Non-uniform plant stands may reduce grain yield in crops like maize. Thus, detecting signs of variability in crop stand density early in the season provides critical information for management decisions and crop yield forecasts. Processing techniques applied on images captured by unmanned aerial vehicles (UAVs) has been used successfully to identify crop rows and estimate stand density and, most recently, to estimate plant-to-plant interval distance. Here, we further test and apply an image processing algorithm on UAV images collected from yield-stability zones in a commercial crop field. Our objective was to implement the algorithm to compare variation of plant-spacing intervals to test whether yield differences within these zones are related to differences in crop stand characteristics. Our analysis indicates that the algorithm can be reliably used to estimate plant counts (precision >95% and recall >97%) and plant distance interval (R2 ~0.9 and relative error <10%). Analysis of the collected data indicated that plant spacing variability differences were small among plots with large yield differences, suggesting that it was not a major cause of yield variability across zones with distinct yield history. This analysis provides an example of how plant-detection algorithms can be applied to improve the understanding of patterns of spatial and temporal yield variability.

47 OTHER INSTRUMENTATION↗

The geographical distribution of difference 100-keV electrons above the earth's atmosphere

Modern soft X-ray astronomical observations are made with large-area proportional counters that have very thin plastic windows. The counters are consequently very sensitive to low energy electrons. An electron with only a few keV of energy can penetrate a typical window, and a flux of approximately 100 electrons per square centimeter sec-ster can double the background counting rate during a typical observation. These electrons produce an undersiable effect which, is impossible to distinguish from X ray data. Consequently, an electron-free region is needed for accurate astronomical observations. Geographical regions of weak electron flux from low altitude satellite data are derived. These regions can be compared with the locations of rocket launching sites. The best sites should be those farthest from electron regions.

Seward, F. D.↗

Urban and regional land use analysis: CARETS and census cities experiment package

The author has identified the following significant results. Temperatures in degrees Celsius were derived from PCM counts using the Pease's modified gray window technique. The Outcalt simulator was setup on the USGS computer. The input data to the model are basically meteorological and geographical in nature. The output data is presented in three matrices.

Alexander, R.↗

Comparison of seven performance measures in a time-delayed manipulation task

Real-time performance data was collected during a pick-up task carried out with a Rancho master-slave manipulator using a minicomputer-based data taker. In addition to the usual task-time measurements, computer algorithms to integrate the energy consumed and to count and time the number of moves were implemented. In addition to these measures, several derived measures such as the fraction of time moving (MRATIO) and mean time per move (MBAR) were obtained in an off-line analysis. Preliminary results of the time delay experiment indicate that two new measures, MRATIO and MBAR, are almost an order of magnitude more sensitive than task time, the conventional measure, in determining performance changes with transmission delays in the range from 0.0 to 1.0s.

Hill, J. W.↗

Radio and X-ray observations of NGC 1851 and NGC 1904

The globular clusters NGC 1851 and NGC 1904, have been observed simultaneously at radio and X-ray wavelengths with the aid of the Green Bank interferometer and the proportional counter on OAO Copernicus. The combined radio and X-ray observations provided simultaneous coverage of each subject for a total of about one hour. Data concerning the radio frequency observations of the two globular clusters are presented in a table. The X-ray counts per frame are shown in a graph as a function of time, taking into account a five day interval in December 1975.

Johnson, H. M.↗

State-of-the-art Space Telescope Digicon performance data

The Digicon has been chosen as the detector for the High Resolution Spectrograph and the Faint Object Spectrograph of the Space Telescope. Both tubes are 512 channel, parallel-output devices and feature CsTe photocathodes on MgF2 faceplates. Using a computer-assisted test facility, the tubes have been characterized with respect to diode array performance, photocathode response (1100-9000 A), and imaging capability. Data are presented on diode dark current and capacitance distributions, pulse height resolution, photocathode quantum efficiency, uniformity and blemishes, dark count rate, distortion, resolution, and crosstalk.

Ginaven, R. O.↗

Study of spectral/radiometric characteristics of the Thematic Mapper for land use applications

The radiometric characteristics of LANDSAT 5 TM data were analyzed. Effects which were found earlier and quantified in LANDSAT 4 TM data were quantified for LANDSAT-5 data as well, including: scan-direction-related signal droop and scan correlated level shifts. Coincident LANDSAT 4 and 5 fully corrected (CCT-PT) TM data were analyzed, and band-by-band relationships between the two sensors were derived in terms of both signal counts and radiance.

Malila, W. A.↗

A Monte Carlo study of parameters affecting computer simulations of crater saturation density

Computer models of cratered surfaces often use inputs of uncertain nature and importance. This work evaluates the sensitivity of the resulting crater-saturation estimates to the input parameters, principally applicable to the study of craters upward from 8 km diameter. In order of decreasing importance, crater saturation simulations are found to be sensitive to: (1) the dynamic range of crater diameters used, (2) the effectiveness of ejecta-blanket obliteration assumed, and (3) the number of points taken to describe the crater rim. The size of the largest crater in proportion to the size of the simulated surface has no effect on the results when the edges of the simulated surface are correctly treated and craters are not counted simply by integers. Craters should be counted by their fractions lying within the simulated area. A similar procedure is recommended when gathering crater size-density data from images.

Woronow, A.↗

Dual-Energy X-Radiography With Gadolinium Filter

Image resolution increased, and cost reduced. Proposed dual-energy x-ray imaging system, continuous bremsstrahlung spectrum from x-ray tube filtered by foil of nonradioactive gadolinium or another rare-earth metal to form two-peaked energy spectrum. After passing through patient or object under examination, filtered radiation detected by array of energy-discriminating, photon-counting detectors. Detector outputs processed to form x-ray image for each peak and possibly enhanced image based on data taken at both peaks.

Rutt, Brian↗

Radio astronomy aspects of the NASA SETI Sky Survey

The application of SETI data to radio astronomy is studied. The number of continuum radio sources in the 1-10 GHz region to be counted and cataloged is predicted. The radio luminosity functions for steep and flat spectrum sources at 2, 8, and 22 GHz are derived using the model of Peacock and Gull (1981). The relation between source number and flux density is analyzed and the sensitivity of the system is evaluated.

Klein, Michael J.↗

Calibration correction of an active scattering spectrometer probe to account for refractive index of stratospheric aerosols

The use of the active scattering spectrometer probe (ASAS-X) to measure sulfuric acid aerosols on U-2 and ER-2 research aircraft has yielded results that are at times ambiguous due to the dependence of particles' optical signatures on refractive index as well as physical dimensions. The calibration correction of the ASAS-X optical spectrometer probe for stratospheric aerosol studies is validated through an independent and simultaneous sampling of the particles with impactors; sizing and counting of particles on SEM images yields total particle areas and volumes. Upon correction of calibration in light of these data, spectrometer results averaged over four size distributions are found to agree with similarly averaged impactor results to within a few percent: indicating that the optical properties or chemical composition of the sample aerosol must be known in order to achieve accurate optical aerosol spectrometer size analysis.

Pueschel, R. F.↗

Radiometric gains of satellite sensors of reflected solar radiation - Results from NASA ER-2 aircraft measurements

A method for using congruent aircraft-satellite observations to calibrate a satellite sensor is presented. A calibrated spectroradiometer at an altitude of 19 km above White Sands, NM, is oriented to view White Sands at the satellite overpass time along the same view vector as the satellite sensor. Collected data are transformed into corresponding estimates of sensor band radiance at the satellite (derived from the aircraft measurements), and average count (from the sensor measurements). These are both averaged across the footprint of the spectroradiometer. Results are presented for the evolution of NOAA-11 Advanced Very High Resolution Radiometer (AVHRR) (Bands 1 and 2) gain between November 1988 and October 1990, and for GOES-6 and GOES-7 VISSR/VAS visible bands during the same period. Estimates of uncertainty in the results are presented, as well as ideas for their reduction in future flights.

Abel, Peter↗

Discovery of Soft X-ray Pulsations from PSR J1231-1411 using NICER

We report the discovery of soft X-ray pulsations from the nearby millisecond pulsar PSR J1231−1411 using the Neutron Star Interior Composition Explorer (NICER). The pulsed emission is characterized by a broad and asymmetric main pulse and a much fainter secondary interpulse, with a total pulsed count rate of 0.055 c s−1 in the 0.35–1.5 keV band. We analyzed Fermi Large Area Telescope (LAT) data to update the pulse timing model covering 10 yr of data and used that model to coherently combine NICER data over a year of observations. Spectral modeling suggests that the flux is dominated by thermal emission from a hot spot (or spots) on the neutron star surface. The phase relationship between the X-ray pulse and the radio and γ rays provides insight into the geometry of the system.

gamma rays↗

Standardization of Geophysical Logging Data at the Hanford Site - 16208

Gamma activity has been measured in boreholes at the US DOE Hanford Site in southeastern Washington State since the 1940's. Over the years, detectors and data recording methods have changed, but the accumulated data provide a record of subsurface gamma activity spanning the period from active operations into interim stabilization. A basic problem is comparability of data between different detectors over a wide range of gamma activity. Many logs are simply presented in terms of raw count rate, and it is difficult to compare count rates between two different detectors, particularly when they have very different response characteristics. The Hanford Gamma Unit (HGU) is proposed as an empirical unit of gamma activity. The HGU is defined in terms of gamma activity at a specified location at the Hanford Borehole Model Facility, and its magnitude is defined such that 1 HGU is approximately equal to typical background gamma activity in uncontaminated soil. The HGU provides a means to convey information about the basic level of subsurface contamination without any implications as to the specific source of the gamma activity. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗