Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Temporal changes in C and N stocks of restored prairie: implications for C sequestration strategies

The recovery of ecosystem C and N dynamics after disturbance can be a slow process. Chronosequence approaches offer unique opportunities to use space-for-time substitution to quantify the recovery of ecosystem C and N stocks and estimate the potential of restoration practices for C sequestration. We studied the distribution of C and N stocks in two chronosequences that included long-term cultivated lands, 3- to 26-year-old prairie restorations, and remnant prairie on two related soil series. Results from the two chronosequences did not vary significantly and were combined. Based on modeling predictions, the recovery rates of different ecosystem components varied greatly. Overall, C stocks recovered faster than N stocks, but both C and N stocks recovered more rapidly for aboveground vegetation than for any other ecosystem component. Aboveground C and N reached 95% of remnant levels in only 13 years and 21 years, respectively, after planting to native vegetation. Belowground plant C and N recovered several decades later, while microbial biomass C, soil organic C (SOC), and total soil N recovered on a century timescale. In the cultivated fields, SOC concentrations were depleted within the surface 25 cm, coinciding with the depth of plowing, but cultivation apparently led to redistribution of soil C, increasing SOC stocks deeper in the soil profile. The restoration of prairie vegetation was effective at rebuilding soil organic matter (SOM) in the surface soil. Accrual rates were maintained at 43 g C {center_dot} m{sup -2} {center_dot} yr{sup -1} and 3 g N {center_dot} m{sup -2} {center_dot} yr{sup -1} in the surface 0.16 Mg/m{sup 2} soil mass during the first 26 years of restoration and were predicted to reach 50% of their storage potential (3500 g C/m{sup 2}) in the first 100 years. We conclude that restoration of tallgrass prairie vegetation can restore SOM lost through cultivation and has the potential to sequester relatively large amounts of SOC over a sustained period of time. Whether restored prairies can retain the C apparently transferred to the subsoil by cultivation practices remains to be seen.

09 BIOMASS FUELS↗

SU-F-T-146: Comparing Monte Carlo Simulations with Commissioning Beam Data for Mevion S250 Proton Therapy System

Purpose: To evaluate the Monte Carlo simulated beam data with the measured commissioning data for the Mevion S250 proton therapy system. Method: The Mevion S250 proton therapy system utilizes a passive double scattering technique with a unique gantry mounted superconducting accelerator and offers effective proton therapy in a compact design concept. The field shaping system (FSS) includes first scattering foil, range modulator wheel (RMW), second scattering foil and post absorber and offers two field sizes and a total of 24 treatment options from proton range of 5 cm to 32 cm. The treatment nozzle was modeled in detail using TOPAS (TOolkit for PArticle Simulation) Monte Carlo code. The timing feathers of the moving modulator wheels were also implemented to generate the Spread Out Bragg Peak (SOBP). The simulation results including pristine Bragg Peak, SOBP and dose profiles were compared with the data measured during beam commissioning. Results: The comparison between the measured data and the simulation data show excellent agreement. For pristine proton Bragg Peaks, the simulated proton range (depth of distal 90%) values agreed well with the measured range values within 1 mm accuracy. The differences of the distal falloffs (depth from distal 80% to 20%) were also found to be less than 1 mm between the simulations and measurements. For the SOBP, the widths of modulation (depth of proximal 95% to distal 90%) were also found to agree with the measurement within 1 mm. The flatness of the simulated and measured lateral profiles was found to be 0.6 % and 1.1 %, respectively. Conclusion: The agreement between simulations and measurements demonstrate that TOPAS could be used as a viable platform to proton therapy applications. The matched simulation results offer a great tool and open opportunity for variety of applications.

60 APPLIED LIFE SCIENCES↗

Time-averaged Spray Analysis in the Near-field Using Broadband and Narrowband X-ray Measurements

The characterization of a spray in the near-field region is challenging because of its high optical density in this region. X-ray based techniques, with weak scatter and strong penetration properties, can provide better characterization than optical assessment techniques in this region. Here, the effects of various operating parameters on the optical depth (defined as the accumulated liquid thickness in the beam path times the X-ray attenuation coefficient) and spray profile of an atomizing spray in the near-field region are evaluated based on time-averaged X-ray analysis techniques. Controlling parameters in the spray structure include swirl ratio, liquid phase Reynolds number, and gas phase Reynolds number. Data from the broadband X-ray radiographs obtained using a tube source at Iowa State University and from focused beam measurements at the Advanced Photon Source at Argonne National Laboratory are compared. The X-ray tube source at Iowa State University was operated at two different energy levels, which reveals that the X-ray tube source energy influenced the magnitude of the optical depth but did not change the shape of the distribution. For the no swirl condition, gas flow rate and liquid flow rate had opposite effects on the spray profile, where the spray widens as the gas flow rate increases and narrows as the liquid flow rate increases. As the swirl ratio increases from 0 to 1, the spray widens and then narrows. Furthermore, the critical swirl ratio at which the spray reaches its widest spread differs at different flow conditions.

42 ENGINEERING↗

Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within {+-}1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Evaluation of a Simple Algorithm to Find Cloud Optical Depth with Emphasis on Thin Ice Clouds

We present here an algorithm for determining cloud optical depth, τ, using data from shortwave broadband irradiances, focusing on the case of optically thin clouds. This method is empirical and consists of applying a one-line equation to the shortwave flux analysis described by Long and Ackerman (2000). We apply this method to cirrus clouds observed at the Atmospheric Radiation Measurement Program’s (ARM) Darwin, Australia site during the Tropical Warm Pool International Cloud Experiment (TWP-ICE) campaign and cirrus clouds observed at ARM’s Southern Great Plains (SGP) site. These cases were chosen because independent verification of cloud optical depth retrievals is possible. For the TWP-ICE case, the calculated optical depths compare favorably (to within about 1 unit) with a “first principles” τ calculated from a vertical profile of ice particle size distributions obtained from an aircraft sounding. For the SGP case, the results from the algorithm correspond reasonably well with τ values obtained from an average over other methods; some of which have been subject to independent verification. The medians of the two time series are 0.79 and 0.81, for the empirical and averaged values, respectively (although such close agreement is likely to be fortuitous). This tool may be applied wherever measurements of the three components of the shortwave broadband flux are available at 1- to 5-minute resolution. Because these measurements are made across the world, it then becomes possible to estimate optical depth at many locations.

54 ENVIRONMENTAL SCIENCES↗

Relating soil gas to weathering using rock and regolith geochemistry

Weathering-induced fracturing (WIF) has been posited to be a mechanism that develops secondary porosity when mineral reaction fronts separate over depth intervals in regolith, and, in particular, when oxidation (which can promote porosity development through volume expansion) occurs deeper than dissolution (which grows porosity through material removal). If this is true, then the protolith’s capacity to reduce O2 (for example, the Fe(II) content) and O2 availability should affect WIF. This study explores the hypothesis that if the ratio of pO2 to pCO2, in soil water, R’(aq), is greater than the ratio of the capacity of the protolith to consume O2 and CO2, R0, then WIF is more likely to occur, and regolith will become thicker. We evaluated this hypothesis by measuring the bulk geochemistry of regolith and rock and monitoring soil gas at three sites, encompassing a wide range of FeO concentrations and regolith thickness: a Pennsylvania (PA) diabase (10.15%; 3.8 m), a Virginia (VA) diabase (10.49%; 1.4 m), and a VA granite (1.45%; 20 m). We inferred soil water O2 concentrations from calculated equilibrium with the measured soil gas pO2. We observed WIF in the VA granite and PA diabase where R’(aq) > R0, while at the site that lacked WIF – VA diabase – the R’(aq) < R0 particularly during the wet season. In the VA diabase, the presence of swelling clays (smectite) limits the ability of the oxidant (O2) to diffuse deeper into the weathering profile during the wet season and microbially accelerated iron oxidation rapidly consumes O2, limiting O2 availability for WIF. Smectite has little to no observable effect on O2 consumption in the PA diabase because the PA diabase is more fractured. A compilation of dissolved soil gas oxidation ratios, the stoichiometric ratio of O2 consumed to CO2 produced, shows that for unsaturated conditions, the mean is -1.45 ± 0.88, which is consistent with aerobic root and microbial respiration and the oxidation of organic matter. For near-saturated conditions, the mean oxidation ratio of the compilation is -3.46 ± 1.79, which is consistent with Fe redox and microbial metabolism under reducing conditions. The consistency between the VA and PA data presented here and the compilation suggests that soil-water surplus drives coupled Fe-redox reactions that may act as a negative feedback, limiting O2 supply and WIF under wetter soil moisture conditions. We defined Rz, the ratio of O2 consumption to CO2 consumption during weathering for each depth interval, z. For all profiles, R’(aq) > Rz near the surface but R’(aq) approaches Rz in the saprolite. We suggest that R’(aq) > Rz in the soil reflects consumption of O2 and production of CO2 due to biotic processes whereas R’(aq) approaching Rz suggests that low fluxes at depth are at least partly dictated by rock and regolith composition, notably tortuosity of pores. In the VA diabase, we observed R’(aq) < Rz occasionally during the wet season in the lowermost soil and saprolite. Thus, at times the O2 availability may be less than the O2 consumption at that depth, consistent with Fe(II) loss and a lack of WIF. Mass-balance calculations show Fe loss in the VA diabase. The influence of rock composition on aqueous O2/CO2 concentrations in saprolite is consistent with the hypothesis that the protolith’s capacity to consume O2 and CO2 has some effect on oxidation and acid consumption deep in the weathering profile.

54 ENVIRONMENTAL SCIENCES↗

Cloud Classes and Radiative Heating profiles at the Manus and Nauru Atmospheric Radiation Measurement (ARM) Sites

The Tropical Western Pacific (TWP) is a convective regime; however, the frequency and depth of convection is dependant on dynamical forcing which exhibits variability on a range of temporal scales and also on location within the region. Manus Island, Papua New Guinea lies in the heart of the western Pacific warm pool region and exhibits frequent deep convection much of the time while Nauru, which lies approximately 20 degrees to the East of Manus, lies in a transition zone where the frequency of convection is dependent on the phase of the El Nino/Southern Oscillation. Because of this difference in dynamical regime, the distribution of clouds and the associated radiative heating is quite different at the two sites. Individual cloud types: boundary layer cumulus, thin cirrus, stratiform convective outflow, do occur at both sites – but with different frequencies. In this study we compare cloud profiles and heating profiles for specific cloud types at these two sites using data from the Atmospheric Radiation Measurement (ARM) Climate Research Facility (ACRF). Results of this comparison indicate that, while the frequency of specific cloud types differ between the two sites as one would expect, the characteristics of individual cloud classes are remarkably similar. This information could prove to be very useful for applying tropical ARM data to the broader region.

54 ENVIRONMENTAL SCIENCES↗

Effective field model of roughness in magnetic nano-structures

An effective field model is introduced here within the micromagnetics formulation, to study roughness in magnetic structures, by considering sub-exchange length roughness levels as a perturbation on a smooth structure. This allows the roughness contribution to be separated, which is found to give rise to an effective configurational anisotropy for both edge and surface roughness, and accurately model its effects with fine control over the roughness depth without the explicit need to refine the computational cell size to accommodate the roughness profile. The model is validated by comparisons with directly roughened structures for a series of magnetization switching and domain wall velocity simulations and found to be in excellent agreement for roughness levels up to the exchange length. The model is further applied to vortex domain wall velocity simulations with surface roughness, which is shown to significantly modify domain wall movement and result in dynamic pinning and stochastic creep effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The effect of surface brightness dimming in the selection of high-z galaxies

Cosmological surface brightness (SB) dimming of the form (1 + z){sup –4} affects all sources. The strong dependence of SB dimming on redshift z suggests the presence of a selection bias when searching for high-z galaxies, i.e., we tend to detect only those galaxies with a high SB. However, unresolved knots of emission are not affected by SB dimming, thus providing a way to test the clumpiness of high-z galaxies. Our strategy relies on the comparison of the total flux detected for the same source in surveys characterized by different depth. For all galaxies, deeper images permit the better investigation of low-SB features. Cosmological SB dimming makes these low-SB features hard to detect when going to higher and higher redshifts. We used the GOODS and HUDF Hubble Space Telescope legacy data sets to study the effect of SB dimming on low-SB features of high-z galaxies and compare it to the prediction for smooth sources. We selected a sample of Lyman-break galaxies at z ∼ 4 (i.e., B {sub 435}-band dropouts) detected in all of the data sets and found no significant trend when comparing the total magnitudes measured from images with different depth. Through Monte Carlo simulations we derived the expected trend for galaxies with different SB profiles. The comparison to the data hints at a compact distribution for most of the rest-frame ultraviolet light emitted from high-z galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

BEYOND 31 mag arcsec{sup −2}: THE FRONTIER OF LOW SURFACE BRIGHTNESS IMAGING WITH THE LARGEST OPTICAL TELESCOPES

The detection of structures in the sky with optical surface brightnesses fainter than 30 mag arcsec{sup −2} (3 σ in 10 × 10 arcsec boxes; r -band) has remained elusive in current photometric deep surveys. Here we show how present-day telescopes of 10 m class can provide broadband imaging 1.5–2 mag deeper than most previous results within a reasonable amount of time (i.e., <10 hr on-source integration). In particular, we illustrate the ability of the 10.4 m Gran Telescopio de Canarias telescope to produce imaging with a limiting surface brightness of 31.5 mag arcsec{sup −2} (3 σ in 10 × 10 arcsec boxes; r -band) using 8.1 hr on source. We apply this power to explore the stellar halo of the galaxy UGC 00180, a galaxy analogous to M31 located at ∼150 Mpc, by obtaining a radial profile of surface brightness down to μ{sub r} ∼ 33 mag arcsec{sup −2}. This depth is similar to that obtained using the star-counts techniques for Local Group galaxies, but is achieved at a distance where this technique is unfeasible. We find that the mass of the stellar halo of this galaxy is ∼4 × 10{sup 9} M {sub ⊙}, i.e., (3 ± 1)% of the total stellar mass of the whole system. This amount of mass in the stellar halo is in agreement with current theoretical expectations for galaxies of this kind.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo study of the depth-dependent fluence perturbation in parallel-plate ionization chambers in electron beams

Purpose: The electron fluence inside a parallel-plate ionization chamber positioned in a water phantom and exposed to a clinical electron beam deviates from the unperturbed fluence in water in absence of the chamber. One reason for the fluence perturbation is the well-known “inscattering effect,” whose physical cause is the lack of electron scattering in the gas-filled cavity. Correction factors determined to correct for this effect have long been recommended. However, more recent Monte Carlo calculations have led to some doubt about the range of validity of these corrections. Therefore, the aim of the present study is to reanalyze the development of the fluence perturbation with depth and to review the function of the guard rings. Methods: Spatially resolved Monte Carlo simulations of the dose profiles within gas-filled cavities with various radii in clinical electron beams have been performed in order to determine the radial variation of the fluence perturbation in a coin-shaped cavity, to study the influences of the radius of the collecting electrode and of the width of the guard ring upon the indicated value of the ionization chamber formed by the cavity, and to investigate the development of the perturbation as a function of the depth in an electron-irradiated phantom. The simulations were performed for a primary electron energy of 6 MeV. Results: The Monte Carlo simulations clearly demonstrated a surprisingly large in- and outward electron transport across the lateral cavity boundary. This results in a strong influence of the depth-dependent development of the electron field in the surrounding medium upon the chamber reading. In the buildup region of the depth-dose curve, the in–out balance of the electron fluence is positive and shows the well-known dose oscillation near the cavity/water boundary. At the depth of the dose maximum the in–out balance is equilibrated, and in the falling part of the depth-dose curve it is negative, as shown here the first time. The influences of both the collecting electrode radius and the width of the guard ring are reflecting the deep radial penetration of the electron transport processes into the gas-filled cavities and the need for appropriate corrections of the chamber reading. New values for these corrections have been established in two forms, one converting the indicated value into the absorbed dose to water in the front plane of the chamber, the other converting it into the absorbed dose to water at the depth of the effective point of measurement of the chamber. In the Appendix, the in–out imbalance of electron transport across the lateral cavity boundary is demonstrated in the approximation of classical small-angle multiple scattering theory. Conclusions: The in–out electron transport imbalance at the lateral boundaries of parallel-plate chambers in electron beams has been studied with Monte Carlo simulation over a range of depth in water, and new correction factors, covering all depths and implementing the effective point of measurement concept, have been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature uncertainty modelling with proxy structural data as geostatistical constraints for well siting: an example applied to Granite Springs Valley, NV, USA

Utilizing existing temperature and structural geology information around Granite Springs Valley, Nevada, we build 3D stochastic temperature models with the aims of evaluating the 3D uncertainty of temperature and choosing between candidate exploration well locations. The data used to support the modelling are measured temperatures and structural proxies from 3D geologic modelling (distance to fault, distance to fault intersections and terminations, Coulomb stress change and dilation tendency), the latter considered ‘secondary’ data. Two stochastic geostatistical techniques are explored for incorporating the structural proxies: cosimulation and local varying mean. With both the cosimulation and local varying mean methods, many equally-likely temperature models (i.e. realizations) are produced, from which temperature probability profiles are calculated at candidate well locations. To aid in choosing between the candidate locations, two quantities summarize the temperature probabilities: V prior and entropy. V prior quantifies the likelihood for economic temperatures at each candidate location, whereas entropy identifies where new information has the most potential to reduce uncertainty. In general, the cosimulation realizations have smoother spatial structure, and extrapolate high temperatures at candidate locations that are located along the direction of the longest spatial correlation, which are down dip from existing temperature logs. The smooth realizations result in tight temperature probability profiles that are easier to interpret, but they have unrealistic temperature reversals in some locations because of the dipping ellipsoid shape created and that the cosimulation technique does not enforce a conductive geothermal gradient as a baseline (i.e. linearly increasing temperature with depth). The local varying mean results produce realizations with more realistic geothermal gradients, with temperatures increasing downward since a depth-temperature relationship is included. However, because they have much noisier spatial nature compared to cosimulation, it is harder to interpret the temperature probability profiles. The different local varying mean results allow the geologist to determine which proxy (e.g. dilation v. distance to fault termination) should be used given the specific geothermal system. In general, V prior from local varying mean results identify locations that are close to high values for the structural proxies: areas with higher probabilities for higher temperatures. The entropy results identify where uncertainty is greatest and therefore new drilling information could be most useful. Though these techniques provide useful information, even when applied to areas of sparse data, our comparison of these two techniques demonstrates the need for new geothermal geostatistics techniques that combine the advantages of these two methods and that are tailored to the spatial uncertainty issues inherent in geothermal exploration.

15 GEOTHERMAL ENERGY↗

Effect of early dark matter halos on reionization

The annihilation of dark matter particles releases energy, ionizing some of the gas in the Universe. We investigate the effect of dark matter halos on reionization. We show that the effect depends on the assumed density profile, the particle mass, and the assumed minimum halo mass. For Navarro-Frenk-White halos and typical WIMPs, we find the effect to be quite small. However, light dark matter candidates in the MeV range can contribute significantly to reionization and can make an important contribution to the measured optical depth. This effect may be used to constrain light dark matter models. We also study the effect of varying the halo density profile on reionization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-CAMPUS-T-04: Measurement of Proton Pencil Beam Spot Profile Using Cherenkov Radiation in Two Dimensional Optical Fiber Arrays

Purpose: Proton therapy aims to deliver a high dose in a well-defined target volume while sparing the healthy surrounding tissues thanks to their inherent depth dose characteristic (Bragg peak). In proton therapy, several techniques can be used to deliver the dose into the target volume. The one that allows the best conformity with the tumor, is called PBS (Pencil Beam Scanning). The measurement of the proton pencil beam spot profile (spot size) and position is very important for the accurate delivery of dose to the target volume with a good conformity. Methods: We have developed a fine segmented detector array to monitor the PBS. A prototype beam monitor using Cherenkov radiation in clear plastic optical fibers (cPOF) has been developed for continuous display of the pencil beam status during the therapeutic proton Pencil Beam Scanning mode operation. The benefit of using Cherenkov radiation is that the optical output is linear to the dose. Pedestal substraction and the gain adjustment between channels are performed. Spot profiles of various pencil beam energies(100 MeV to 226 MeV) are measured. Two dimensional gaussian fit is used to analyze the beam width and the spot center. The results are compared with that of Lynx(Scintillator-based sensor with CCD camera) and EBT3 Film. Results: The measured gaussian widths using fiber array system changes from 13 to 5 mm for the beam energies from 100 to 226 MeV. The results agree well with Lynx and Film within the systematic error. Conclusion: The results demonstrate good monitoring capability of the system. Not only measuing the spot profile but also monitoring dose map by accumulating each spot measurement is available. The x-y monitoing system with 128 channel readout will be mounted to the snout for the in-situ real time monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

High-resolution Bayesian spatial autocorrelation (SPAC) quasi-3-D Vs model of Utah FORGE site with a dense geophone array

SUMMARY We expand the application of spatial autocorrelation (SPAC) from typical 1-D Vs profiles to quasi-3-D imaging via Bayesian Monte Carlo inversion (BMCI) using a dense nodal array (49 nodes) located at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site. Combinations of 4 and 9 geophones in subarrays provide for 36 and 25 1-D Vs profiles, respectively. Profiles with error bars are determined by calculating coherency functions that fit observations in a frequency range of 0.2–5 Hz. Thus, a high-resolution quasi-3-D Vs model from the surface to 2.0 km depth is derived and shows that surface-parallel sedimentary strata deepen to the west, consistent with a 3-D seismic reflection survey. Moreover, the resulting Vs profile is consistent with a Vs profile derived from distributed acoustic sensing (DAS) data located in a borehole at the FORGE site. The quasi-3-D velocity model shows that the base of the basin dips ∼22° to the west and topography on the basement interface coincident with the Mag Lee Wash suggests that the bedrock interface is an unconformity.

Geochemistry & Geophysics↗

Utah FORGE: Seismic Velocity Models, February 2021

This dataset contains a map, showing the Utah FORGE seismic stations, and seismic velocity model data. There are 61 1-D velocity models which are in a compressed TAR file. A paper is referenced at the end of this description which discusses the use of these data in 3D modelling. The paper summary follows: We expand the application of spatial autocorrelation (SPAC) from typical 1-D Vs profiles to quasi-3-D imaging via Bayesian Monte Carlo inversion (BMCI) using a dense nodal array (49 nodes) located at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site. Combinations of 4 and 9 geophones in subarrays provide for 36 and 25 1-D Vs profiles, respectively. Profiles with error bars are determined by calculating coherency functions that fit observations in a frequency range of 0.2-5 Hz. Thus, a high-resolution quasi-3-D Vs model from the surface to 2.0 km depth is derived and shows that surface-parallel sedimentary strata deepen to the west, consistent with a 3-D seismic reflection survey. Moreover, the resulting Vs profile is consistent with a Vs profile derived from distributed acoustic sensing (DAS) data located in a borehole at the FORGE site. The quasi-3-D velocity model shows that the base of the basin dips ~22 degrees to the west and topography on the basement interface coincident with the Mag Lee Wash suggests that the bedrock interface is an unconformity. Reference: Zhang, H. and K. L. Pankow (2021). High-resolution Bayesian spatial auto-correlation (SPAC) pseudo-3D Vs model of Utah FORGE site with a dense geophone array, Geophys. Res. Int, https://doi.org/10.1093/gji/ggab049

15 GEOTHERMAL ENERGY↗

Spatially-Resolved Proteomics: Rapid Quantitative Analysis of Laser Capture Microdissected Alveolar Tissue Samples

Global proteomics approaches allow characterization of whole tissue lysates to an impressive depth. However, it is now increasingly recognized that to better understand the complexity of multicellular organisms, global protein profiling of specific spatially defined regions/substructures of tissues (i.e. spatially-resolved proteomics) is essential. Laser capture microdissection (LCM) enables microscopic isolation of defined regions of tissues preserving crucial spatial information. However, current proteomics workflows entail several manual sample preparation steps and are challenged by the microscopic mass-limited samples generated by LCM, and that impact measurement robustness, quantification, and throughput. Here, we coupled LCM with a fully automated sample preparation workflow that with a single manual step allows: protein extraction, tryptic digestion, peptide cleanup and LC-MS/MS analysis of proteomes from microdissected tissues. Benchmarking against the current state of the art in ultrasensitive global proteomic analysis, our approach demonstrated significant improvements in quantification and throughput. Using our LCM-SNaPP proteomics approach, we characterized to a depth of more than 3,400 proteins, the ontogeny of protein changes during normal lung development in laser capture microdissected alveolar tissue containing ~4,000 cells per sample. Importantly, the data revealed quantitative changes for 350 low abundance transcription factors and signaling molecules, confirming earlier transcript-level observations and defining seven modules of coordinated transcription factor/signaling molecule expression patterns, suggesting that a complex network of temporal regulatory control directs normal lung development with epigenetic regulation fine-tuning pre-natal developmental processes. Furthermore, our LCM-proteomics approach facilitates efficient, spatially-resolved, ultrasensitive global proteomics analyses in high-throughput that will be enabling for several clinical and biological applications.

60 APPLIED LIFE SCIENCES↗

Determination of the magnetic penetration depth in a superconducting Pb film

By means of scanning Hall probe microscopy technique, we accurately map the magnetic field pattern produced by Meissner screening currents in a thin superconducting Pb stripe. The obtained field profile allows us to quantitatively estimate the Pearl length Λ without the need of pre-calibrating the Hall sensor. This fact contrasts with the information acquired through the spatial field dependence of an individual flux quantum where the scanning height and the magnetic penetration depth combine in a single inseparable parameter. The derived London penetration depth λ{sub L} coincides with the values previously reported for bulk Pb once the kinetic suppression of the order parameter is properly taken into account.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗