Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Skylab atmospheric contamination control

The Skylab contamination removal systems, preflight analysis and testing, and flight results are described. Results indicate that the combination of materials selection, the onboard removal devices, and the offgassing tests proved to be an effective means of controlling spacecraft contaminant levels.

Ray, C. D.↗

Potential utilization of the NASA/George C. Marshall Space Flight Center in earthquake engineering research

Earthquake engineering research capabilities of the National Aeronautics and Space Administration (NASA) facilities at George C. Marshall Space Flight Center (MSFC), Alabama, were evaluated. The results indicate that the NASA/MSFC facilities and supporting capabilities offer unique opportunities for conducting earthquake engineering research. Specific features that are particularly attractive for large scale static and dynamic testing of natural and man-made structures include the following: large physical dimensions of buildings and test bays; high loading capacity; wide range and large number of test equipment and instrumentation devices; multichannel data acquisition and processing systems; technical expertise for conducting large-scale static and dynamic testing; sophisticated techniques for systems dynamics analysis, simulation, and control; and capability for managing large-size and technologically complex programs. Potential uses of the facilities for near and long term test programs to supplement current earthquake research activities are suggested.

Scholl, R. E.↗

Solar Variability and the Near-Earth Environment: Mining Enhanced Low Dose Rate Sensitivity Data From the Microelectronics and Photonics Test Bed Space Experiment

This effort is a detailed analysis of existing microelectronics and photonics test bed satellite data from one experiment, the bipolar test board, looking to improve our understanding of the enhanced low dose rate sensitivity (ELDRS) phenomenon. Over the past several years, extensive total dose irradiations of bipolar devices have demonstrated that many of these devices exhibited ELDRS. In sensitive bipolar transistors, ELDRS produced enhanced degradation of base current, resulting in enhanced gain degradation at dose rates <0.1 rd(Si)/s compared to similar transistors irradiated at dose rates >1 rd(Si)/s. This Technical Publication provides updated information about the test devices, the in-flight experiment, and both flight-and ground-based observations. Flight data are presented for the past 5 yr of the mission. These data are compared to ground-based data taken on devices from the same date code lots. Information about temperature fluctuations, power shutdowns, and other variables encountered during the space flight are documented.

Turflinger, T.↗

High-Temperature Probe Station Developed to Characterize Microwave Devices Through 500 C

A photograph and a block diagram of the high-temperature probe station are shown. The system consists of the ceramic heater mounted on a NASA shuttle tile insulator, a direct current power supply, a personal-computer-based data acquisition and temperature controller, microwave probes, a microscope, and a network analyzer. The ability to perform microwave tests at high temperatures is becoming necessary. There is now a need for sensors and communication circuits that can operate at 500 C and above for aircraft engine development and monitoring during flight. To address this need, researchers have fabricated devices using wide bandgap semiconductors such as SiC with targeted operating temperatures of 500 to 600 C. However, the microwave properties of these devices often change drastically with temperature, so any designs that are intended to be used in such an environment must be characterized at high temperatures. For some reliability, lifetime, and direct-current testing, the device under test can be packaged and characterized in an oven. However, for RF and microwave measurements, it is usually not possible to establish a calibrated reference plane at the device terminals within a package. In addition, the characteristics of the package would vary over a 500 C temperature range, and this would have to be accounted for when the data were analyzed. A high temperature probe station allows circuits and devices to be characterized through on wafer measurements across a broad temperature range with known reference plane. The conventional, commercially available thermal wafer-probe stations that are used to evaluate microwave devices across a controlled temperature range have a typical upper limit of 200 C. Standalone thermal heating chucks are available with an extended upper temperature range of 300 to 400 C. To effectively characterize devices at temperatures up to and surpassing 500 C, Glenn researchers developed a custom probe station. In the past, custom probe stations have been developed to test devices under other extreme environments, such as cryogenic temperatures as low as 37 K. Similarly, this custom probe station was specifically modified for high-temperature use. It allows devices to be measured quickly and flexibly, without the use of wire bonds and test fixtures. The probe station is shown making scattering parameter measurements from 1 to 50 GHz with a Hewlett-Packard 8510C Network Analyzer. There is a half-wafer of silicon directly on top of the heater to provide a uniform heated platform for our sample. A quarter wafer of silicon carbide forms the substrate for our test circuit of several transmission lines.

Downey, Alan N.↗

Cartridge firing device designed for attachment, release and ejection of a satellite

Design considerations of a cartridge firing device are described. Emphasis is placed on performances regarding satellite attachment and accuracies of the path and velocity during separation and ejection. Tests conducted to demonstrate the device efficiency are discussed. Test set-up for velocity measurement, parameters affecting the ejection velocity, and gas pressure of cartridge fired generators are among the factors covered.

Pierron, L.↗

Utilization survey of prototype structural test article

A survey was conducted of six aerospace companies and two NASA agencies to determine how prototype structural test articles are used in flight operations. The prototype structures are airframes and similar devices which are used for testing and generally are not flown. The survey indicated the following: (1) prototype test articles are not being discarded after development testing is complete, but are used for other purposes, (2) only two cases of prototypes being refurbished and flown were identified, (3) protective devices and inspection techniques are available to prevent or minimize test article damage, (4) substitute programs from design verification are availabel in lieu of using prototype structural articles, and (5) there is a trend away from dedicated test articles. Four options based on these study results were identified to reduce test and hardware costs without compromising reliability of the flight program.

Baber, S.↗

The Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) Sensor

The DNA Medicine Institute has produced a reusable microfluidic device that performs rapid, low-cost cell counts and measurements of electrolytes, proteins, and other biomarkers. The rHEALTH sensor is compact and portable, and it employs cutting-edge fluorescence detection optics, innovative microfluidics, and nanostrip reagents to perform a suite of hematology, chemistry, and biomarker assays from a single drop of blood. A handful of current portable POC devices provide generalized blood analysis, but they perform only a few tests at a time. These devices also rely on disposable components and depend on diverse detection technologies to complete routine tests-all ill-suited for space travelers on extended missions. In contrast, the rHEALTH sensor integrates sample introduction, processing, and detection with a compact, resource-conscious, and efficient design. Developed to monitor astronaut health on the International Space Station and during long-term space flight, this microscale lab analysis tool also has terrestrial applications that include POC diagnostics conducted at a patient's bedside, in a doctor's office, and in a hospital.

Chan, Eugene↗

In-flight friction and wear mechanism

A unique mechanism developed for conducting friction and wear experiments in orbit is described. The device is capable of testing twelve material samples simultaneously. Parameters considered critical include: power, weight, volume, mounting, cleanliness, and thermal designs. The device performed flawlessly in orbit over an eighteen month period and demonstrated the usefulness of this design for future unmanned spacecraft or shuttle applications.

Devine, E. J.↗

TOWARD LOW-COST FABRICATION OF MICROCHANNEL PROCESS TECHNOLOGIES - COST MODELING FOR MANUFACTURING DEVELOPMENT

Chemical and energy conversion systems based on microchannel process technology (MPT) demonstrate high performance in applications in which rates are controlled by diffusive heat and mass transfer flux. The performance of MPT-based heat exchangers, absorbers/desorbers and chemical reactors all benefit from process intensification and have been used in a variety of mobile energy conversion systems including fuel reformers/converters, heat pumps and waste heat scavenging technologies. The service environments typical of MPTs often require the devices to be fabricated from metals such as aluminum, titanium, stainless steel or high temperature super alloys. Flow channels and associated critical dimensions in these devices can be as small as 50 um, but generally range from 100 to 1000 um in width and height with characteristic flow channel lengths normally in the mm to cm range. High surface area architectures (e.g. wicks or textured surfaces) are often included in the flow channels as well for enhanced mass transfer and/or catalytic functionality. Fabrication of MPT devices has historically been performed using a stacked-shim approach in which individual metal sheets are first patterned with micro- and meso-scale flow channels and subsequently bonded in a stack to create an array of miniaturized, parallel flow paths. Typical proof-of-concept fabrication efforts have utilized photo chemical machining (PCM) for shim patterning and diffusion bonding or diffusion brazing for joining of shim stacks. While flexible and capable of supporting technology demonstration, however, these techniques can be expensive at prototyping volumes. The high fabrication cost associated with these prototyping processes has contributed to a perception that MPT technology is expensive and will be relegated to a small application space. Recent work at the Microproducts Breakthrough Institute (MBI) has focused on exploring the cost structure of high volume manufacturing of MPT devices in effort to identify new paths to lower cost fabrication. Through systematic exploration of fabrication process capabilities and associated cost structures, the MBI is developing volume-sensitive cost estimation models for predicting manufacturing costs of MPT devices fabricated using different processing technologies. The process-based cost models are used to develop an understanding of the economic trade-offs between candidate processes and are utilized in a design for manufacturing approach to MPT device fabrication. In this paper we present results and analysis of the cost modeling effort to date and apply the methodology in case study of a stainless steel MPT device designed, built and tested by Pacific Northwest National Laboratory. Extensions of the model to adjacent material sets and the interaction of device designs with fabrication processes will be discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-Situ Gamma Radiation Mapping Device - 19353

The SRNL developed GrayQb{sup TM} is a passive, low cost gamma radiation mapping device which uses a tungsten pinhole and a phosphor storage plate (PSP) to generate images. Presently, the device requires retrieval to extract images off the PSP using an external scanner. In partnership with Los Alamos National Lab (LANL), SRNL has developed an in-situ GrayQb{sup TM} radiation mapping device eliminating the need to remove the radiation sensitive phosphor storage plate (PSP) from the device for scanning between exposures. By incorporating a customized version of the LANL patented MiniMax camera-based PSP reader system into the GrayQb{sup TM} housing, the exposed PSP can now be read in-situ and digitally transmitted to a remote computer for viewing. In-situ imaging is a valuable addition to GrayQb{sup TM} because of the reduced need of personnel interaction which mitigates risk as well as the option for multiple images being acquired during one deployment. Upgrades implemented which allow for in-situ imaging to be performed include using the tungsten pinhole, a PSP, red LEDs, a blue light filter, and a commercial off the shelf (COTS) color camera. The images are transmitted wirelessly to an external computer. This presentation will discuss the selection, characteristics, and testing of the camera-based PSP reading system, improved PSP materials, and the results/performance of the upgraded GrayQb{sup TM} device. Testing has been performed with simulated radiation exposures as well as A-241 and Cs-137 button sources. These upgrades and tests have been performed over a 12-month period and this presentation will be a summary and conclusion to this year long project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantitative Prediction of Perovskite Stability Using Accelerated Testing and Machine Learning

PV technologies based on hybrid perovskites offer the potential for reducing solar cell costs, but they are particularly vulnerable to degradation by environmental factors such as moisture, oxygen, and illumination. Commercialization will require not only stable materials and device architectures but also accelerated testing protocols and models that can predict degradation from the accelerated testing data. Here, we report results from in situ photoluminescence (PL) and photoconductivity (PC) measurements during perovskite degradation with simultaneous optical transmittance (Tr) measurements or reflected dark field (DF) imaging. From PL, PC, Tr, and DF, we determine (respectively) the steady-state quasi-Fermi level splitting, the mean effective carrier diffusion length, the extent of conversion of perovskite to higher bandgap degradation products, and the extent of scattering from domains with different orientation or composition, all as a function of time during degradation. Simultaneous measurement of PL-PC-Tr or PL-PC-DF on perovskite absorbers in an environmental chamber over a wide range of humidity, oxygen, temperature, and illumination levels yields a rich data set. We use machine learning to develop a model that accurately predicts (within 10%) the time for the diffusion length to decrease to 85% of its initial value. The model takes the environmental conditions and the first few measurements from the PL-PC-Tr or PL-PC-DF experiment as input. Thus, the model provides a framework to interpret the results of accelerated testing of absorber materials. One of the dominant features in the model of degradation for CH 3 NH 3 PbI 3 is the initial rate at which transmittance increase. For devices with opaque contacts, the pixel-averaged rate of change of the intensity in dark-field images can be used in place of transmittance. Results are also presented on full PV devices with in-situ current-voltage (JV) measurements. Here, the data from simultaneous PL-DF-JV under environmental stresses reveal intimate connection between degradation and shunts and provide a framework to extend accelerated testing to devices. Further, the presentation reveals underlying universal behavior in degradation pathways over a broad range of environmental stresses and perovskite compositions.

14 SOLAR ENERGY↗

An evaluation of strain measuring devices for ceramic composites

A series of tensile tests was conducted on SiC/reaction bonded silicon nitrides (RBSN) composites using different methods of strain measurement. The tests were used to find the optimum strain sensing device for use with continuous fiber reinforced ceramic matrix composites in ambient and high temperature environments. Bonded resistance gages were found to offer excellent performance for room temperature tests. The clip-on gage offers the same performance, but less time is required for mounting it to the specimen. Low contact force extensometers track the strain with acceptable results at high specimen temperatures. Silicon carbide rods with knife edges are preferred. The edges must be kept sharp. The strain measuring devices should be mounted on the flat side of the specimen. This is in contrast to mounting on the rough thickness side.

Gyekenyesi, John Z.↗

An evaluation of strain measuring devices for ceramic composites

A series of tensile tests were conducted on SiC/RBSN composites using different methods of strain measurement. The tests were used to find the optimum strain sensing device for use with continuous fiber reinforced ceramic matrix composites in ambient and high temperature environments. Bonded resistance strain gages were found to offer excellent performance for room temperature tests. The clip-on gage offers the same performance but significantly less time is required for mounting it to the specimen. Low contact force extensometers track the strain with acceptable results at high specimen temperatures. Silicon carbide rods with knife edges are preferred. The edges must be kept sharp. The strain measuring devices should be mounted on the flat side of the specimen. This is in contrast to mounting on the rough thickness side.

Gyekenyesi, John Z.↗

To Cage or Not to Cage Seagrass; Is There Even a Question?

To Cage or Not to Cage Seagrass; Is There Even a Question? Loraé T. Simpson1, Morgan K. Gilligan1, Douglas M. Scheidt2 1Florida Oceanographic Society, Stuart, FL; 2Herndon Solutions Group/NEMCON, Kennedy Space Center, FL Contact email: lsimpson@floridaocean.org Diminished water quality has led to the decline of seagrasses and their associated ecosystem services in the Banana River Lagoon (BRL), resulting in increased restoration initiatives. Restoration success may be hindered by herbivory and the addition of herbivore exclusion devices may limit grazing stress on newly established seagrasses. These structures may alter sediment dynamics, influencing seagrass productivity. To test whether herbivore exclusion devices impact restoration success and sediment dynamics, we caged half of our seagrass restoration plots in the BRL. Treatments were monitored monthly for seagrass growth, and at three months for porewater nutrients, sediment bulk density, and carbon to nitrogen ratio. On average, caged plots had 87% more seagrass cover and 81% taller blades than control plots, highlighting the importance of caging newly transplanted seagrasses. There was no significant difference in porewater or sediment characteristics between treatments, suggesting that pedogensis and nutrient cycling need extended monitoring to capture changes in temporal scales.

Indian River Lagoon↗

To Cage or Not to Cage Seagrass; Is There Even a Question?

Diminished water quality has led to the decline of seagrasses and their associated ecosystem services in the Banana River Lagoon (BRL), resulting in increased restoration initiatives. Restoration success may be hindered by herbivory and the addition of herbivore exclusion devices may limit grazing stress on newly established seagrasses. These structures may alter sediment dynamics, influencing seagrass productivity. To test whether herbivore exclusion devices impact restoration success and sediment dynamics, we caged half of our seagrass restoration plots in the BRL. Treatments were monitored monthly for seagrass growth, and at three months for porewater nutrients, sediment bulk density, and carbon to nitrogen ratio. On average, caged plots had 87% more seagrass cover and 81% taller blades than control plots, highlighting the importance of caging newly transplanted seagrasses. There was no significant difference in porewater or sediment characteristics between treatments, suggesting that pedogensis and nutrient cycling need extended monitoring to capture changes in temporal scales.

Indian River Lagoon↗

Cybersecurity Certification Standard for Distributed Energy Resources

Cybersecurity Certification Standard for Inverter Based Resources led by UL, and contributed to by NREL, is a certification standard for devices and their cyber security practices. The standard, which is being developed and led by UL, contains certification and testing processes for the devices to be certified before they are deployed in the field. The importance of the standard is to ensure that all DER devices have all the five pillars of cybersecurity, in which the baseline cybersecurity posture of the DER industry will be elevated.

certification standard↗

Non-destructive Testing (NDT) of metal cracks using a high Tc rf-SQUID and eddy current method

A SQUID is the most sensitive device to detect change in magnetic field. A nondestructive testing (NDT) device using high temperature SQUID's and eddy current method will be much more sensitive than those currently used eddy current systems, yet much cheaper than one with low temperature SQUID's. In this paper, we present our study of such a NDT device using a high temperature superconducting rf-SQUID as a gradiometer sensor. The result clearly demonstrates the expected sensitivity of the system, and indicates the feasibility of building a portable HTS SQUID NDT device with the help from cryocooler industry. Such a NDT device will have a significant impact on metal corrosion or crack detection technology.

Lu, D. F.↗