Search NASA⌕ Search

SEARCH · Search NASA

Results for “embedded methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Non-propagating structures and propagating waves in solar wind turbulence revealed by simulations and observations

Structures and waves are common features of solar wind turbulence at various scales. The interplay between structures and waves is important for processes such as the turbulent energy cascade, plasma heating, and particle scattering. Our understanding of turbulence has been advanced by not only new space missions and numerical simulations, but also techniques that have been developed to interpret the rapidly growing turbulence data. We review basic models of turbulence with a specific focus on the analysis methods for understanding magnetic structures and waves. MHD and kinetic waves in single-spacecraft time series measurements can be identified through mode decomposition or their characteristic polarization signatures. The structures in this paper are considered as zero-frequency, non-propagating or convected modes embedded in the solar wind. The synergy between observations and simulations is most evident in the application of spatial-temporal analysis to multi-spacecraft observation and turbulence simulations. The spatial-temporal analysis has greatly improved our understanding of structures and waves in turbulence. We conclude by discussing prospects for future research.

79 ASTRONOMY AND ASTROPHYSICS↗

Challenging thermodynamics: combining immiscible elements in a single-phase nano-ceramic

Abstract The Hume-Rothery rules governing solid-state miscibility limit the compositional space for new inorganic material discovery. Here, we report a non-equilibrium, one-step, and scalable flame synthesis method to overcome thermodynamic limits and incorporate immiscible elements into single phase ceramic nanoshells. Starting from prototype examples including (NiMg)O, (NiAl)O x , and (NiZr)O x , we then extend this method to a broad range of Ni-containing ceramic solid solutions, and finally to general binary combinations of elements. Furthermore, we report an “encapsulated exsolution” phenomenon observed upon reducing the metastable porous (Ni 0.07 Al 0.93 )O x to create ultra-stable Ni nanoparticles embedded within the walls of porous Al 2 O 3 nanoshells. This nanoconfined structure demonstrated high sintering resistance during 640 h of catalysis of CO 2 reforming of methane, maintaining constant 96% CH 4 and CO 2 conversion at 800 °C and dramatically outperforming conventional catalysts. Our findings could greatly expand opportunities to develop novel inorganic energy, structural, and functional materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-559: High-Resolution Scintillating Fiber Array for In-Vivo Real-Time SRS and SBRT Patient QA

Purpose: A high-resolution scintillating fiber detector was built for in-vivo real-time patient specific quality assurance (QA). The detector is designed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) to monitor treatment delivery and detect real-time deviations from planned dose to increase patient safety and treatment accuracy. Methods: The detector consists of two high-density scintillating fiber arrays layered to form an X-Y grid which can be attached to the accessory tray of a medical linac for SBRT and cone SRS treatment QA. Fiber arrays consist of 128 scintillating fibers embedded within a precision-machined, high-transmission polymer substrate with 0.8mm pitch. The fibers are coupled on both ends to high-sensitivity photodetectors and the output is recorded through a high-speed analog-to-digital converter to capture the linac pulse sequence as treatment delivery progresses. The detector has a software controlled 360 degree rotational system to capture angular beam projections for high-resolution beam profile reconstruction. Results: The detector was validated using SRS cone sizes from 6mm to 34mm and MLC defined field sizes from 5×5mm2 to 100×100mm2. The detector output response is linear with dose and is dose rate independent. Each field can be reconstructed accurately with a spatial resolution of 0.8mm and the current beam output is displayed every 50msec. Dosimetric errors of 1% with respect to the treatment plan can be identified and clinically significant deviations from the expected treatment can be displayed in real-time to alert the therapists. Conclusion: The high resolution detector is capable of reconstructing beam profiles in real-time with submillimeter resolution and 1% dose resolution. This system has the ability to project in-vivo both spatial and dosimetric errors during SBRT and SRS treatments when only a non-clinically significant fraction of the intended dose was delivered. The device has the potential to establish new standards for in-vivo patient specific QA.

60 APPLIED LIFE SCIENCES↗

Baselining the Indirect Effect by Improving Quantification of Sea Spray and Marine Sources at Ascension Island (Final Report)

Oceans cover two-thirds of the Earth and understanding the interactions of aerosols with clouds in these large marine regions requires quantifying the man-made contributions to the budget of cloud-drop forming particles (known as cloud condensation nuclei, or CCN) relative to the non-manmade “baseline” conditions and understanding the meteorology of boundary layer clouds. Modeling studies have shown substantial uncertainties and sensitivities to natural marine CCN sources, meaning that to reduce uncertainties in indirect effects we must be able to better quantify the CCN budget in ocean regions. While models provide important constraints on these uncertainties, actually reducing uncertainties requires substantial observations in open-ocean and coastal regions in order to establish the baseline on which manmade emissions are added. The tropical South Atlantic Ocean is one of the least-sampled regions of the planet, making the comprehensive measurements of the Department of Energy Atmospheric Radiation Measurement Layered Atlantic Smoke Interactions with Clouds (LASIC) campaign provides the longest record of aerosol size distribution measurements from a differential mobility analyzer in a cloud-influenced marine location in the ARM database, with 17 months of ground-based aerosol size distribution measurements. This project addressed the research topic of Aerosol-Cloud Interactions (ACI) by supporting three publications from the LASIC measurements: 1. The ARM measurements were combined with a new value-added technique that was pioneered by the Russell group for quantifying sea salt. This quantification of sea salt uses supermicron scattering measurements for retrieving reasonable sea spray mass concentrations, providing the best-available, observationally-constrained estimate of the sea spray mode properties when supermicron size distribution measurements are not available. 2. The fitted modes of the distribution were used to investigate the signatures of cloud processing for very clean to very smoky aerosol conditions, revealing not only differences in the particles that activate in clouds but also in the mechanisms that control that droplet formation process. In clean air, the size required to form a cloud droplet is influenced by the number of particles, as well as how quickly particles take up water during growth in cloud. 3. Building on this aerosol characterization, cloud and meteorological conditions were used to evaluate aerosol-related changes in cloud albedo and optical depth. We introduced a new method of decomposing the impact of aerosols on clouds known as the Twomey effect by incorporating retrieved supersaturation from two independent sets of observations to constrain the feedback of aerosol particles on cloud properties. The method quantifies the reduction of the Twomey effect at high aerosol concentrations, which has never been explained quantitatively by observations. In addition, the results provide the first direct validation for the conditions observed in the tropical South Atlantic of a parcel-based approach that is embedded in many climate models. Together these findings illustrate how ARM extended field campaigns in stratocumulus-covered regions can be used to constrain ACI processes with direct observations, providing specific radiative effects without models. By making such process-specific constraints available to improve ACI in global climate models, ARM observations play a key role in supporting model development.

58 GEOSCIENCES↗

The Double-edged Sword of Data-driven Super-Resolution: Adversarial Super-resolution Models

Data-driven super-resolution (SR) methods are often integrated into imaging pipelines as preprocessing steps to improve downstream tasks such as classification and detection. However, these SR models introduce a previously unexplored attack surface into imaging pipelines. In this paper, we present AdvSR, a framework demonstrating that adversarial behavior can be embedded directly into SR model weights during training, requiring no access to inputs at inference time. Unlike prior attacks that perturb inputs or rely on backdoor triggers, AdvSR operates entirely at the model level. By jointly optimizing for reconstruction quality and targeted adversarial outcomes, AdvSR produces models that appear benign under standard image quality metrics while inducing downstream misclassification. We evaluate AdvSR on three SR architectures (SRCNN, EDSR, SwinIR) paired with a YOLOv11 classifier and demonstrate that AdvSR models can achieve high attack success rates with minimal quality degradation. These findings highlight a new model-level threat for imaging pipelines, with implications for how practitioners source and validate models in safety-critical applications.

Sullivan, Haley [ORNL] (ORCID:0000000274069217)↗

Separation of components from a fluid by solids production

A method for separating components from a fluid is disclosed. A cooling element is provided and is disposed in contact with a distal side of one or more thermally-conductive surfaces. One or more resistive heating elements are provided and are disposed in contact with or embedded in a proximal side of the one or more thermally-conductive surfaces. A fluid comprising one or more secondary components is provided. The fluid is passed across the one or more thermally conductive surfaces, the one or more secondary components freezing, crystallizing, desublimating, depositing, condensing, or combinations thereof, out of the fluid. The one or more resistive heating elements engage such that the one or more solid secondary components detach and pass out the solids outlet. The one or more resistive heating elements disengage, restarting production of the one or more solid secondary components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Standardized Architecture for a Mega-Biobank Phenomic Library: The Million Veteran Program (MVP)

Electronic health records (EHRs) provide a wealth of data for phenotype development in population health studies, and researchers invest considerable time to curate data elements and validate disease definitions. The ability to reproduce well-defined phenotypes increases data quality, comparability of results and expedites research. In this paper, we present a standardized approach to organize and capture phenotype definitions, resulting in the creation of an open, online repository of phenotypes. This resource captures phenotype development, provenance and process from the Million Veteran Program, a national mega-biobank embedded in the Veterans Health Administration (VHA). To ensure that the repository is searchable, extendable, and sustainable, it is necessary to develop both a proper digital catalog architecture and underlying metadata infrastructure to enable effective management of the data fields required to define each phenotype. Our methods provide a resource for VHA investigators and a roadmap for researchers interested in standardizing their phenotype definitions to increase portability.

Knight, Kathryn↗

Standardized Architecture for a Mega-Biobank Phenomic Library: The Million Veteran Program (MVP)

Electronic health records (EHRs) provide a wealth of data for phenotype development in population health studies, and researchers invest considerable time to curate data elements and validate disease definitions. The ability to reproduce well-defined phenotypes increases data quality, comparability of results and expedites research. In this paper, we present a standardized approach to organize and capture phenotype definitions, resulting in the creation of an open, online repository of phenotypes. This resource captures phenotype development, provenance and process from the Million Veteran Program, a national mega-biobank embedded in the Veterans Health Administration (VHA). To ensure that the repository is searchable, extendable, and sustainable, it is necessary to develop both a proper digital catalog architecture and underlying metadata infrastructure to enable effective management of the data fields required to define each phenotype. Our methods provide a resource for VHA investigators and a roadmap for researchers interested in standardizing their phenotype definitions to increase portability.

Knight, Kathryn↗

SU-E-J-213: Imaging and Treatment Isocenter Verification of a Gantry Mounted Proton Therapy System

Purpose: The Mevion proton therapy machine is the first to feature a gantry mounted sychro-cyclotron. In addition, the system utilizes a 6D motion couch and kV imaging for precise proton therapy. To quantify coincidence between these systems, isocentricity tests were performed based on kV imaging alignment using radiochromic film. Methods: The 100 ton gantry and 6D robotic couch can rotate 190° around isocenter to provide necessary beam angles for treatment. The kV sources and detector panels are deployed as needed to acquire orthogonal portals. Gantry and couch mechanical isocenter were tested using star-shots and radiochromic-film (RCF). Using kV imaging, the star-shot phantom was aligned to an embedded fiducial and the isocenter was marked on RCF with a pinprick. The couch and gantry stars were performed by irradiating films at every 45° and 30°, respectively. A proton beam with a range and modulation-width of 18 cm was used. A Winston-Lutz test was also performed at the same gantry and couch rotations using a custom jig holding RCF and a tungsten ball placed at isocenter. A 2 cm diameter circular aperture was used for the irradiation. Results: The couch star-shot indicated a minimum tangent circle of 0.6 mm, with a 0.9 mm offset from the manually marked isocenter. The gantry star-shot showed a 0.6 mm minimum tangent circle with a 0.5 mm offset from the pinprick. The Winston Lutz test performed for gantry rotation showed a maximum deviation from center of 0.5 mm. Conclusion: Based on star-shots and Winston-Lutz tests, the proton gantry and 6D couch isocentricity are within 1 mm. In this study, we have shown that the methods commonly utilized for Linac characterization can be applied to proton therapy. This revolutionary proton therapy system possesses excellent agreement between the mechanical and radiation isocenter, providing highly precise treatment.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-118: Dose Verification for Accuboost Applicators Using TLD, Ion Chamber and Gafchromic Film Measurements

Purpose: To verify dose delivered with HDR Accuboost applicators using TLD, ion chamber and Gafchromic film measurements and to examine applicator leakage. Methods: A microSelectron HDR unit was used to deliver a dose of 50cGy to the mid-plane of a 62mm thick solid water phantom using dwell times from Monte Carlo pre-calculated nomograms for a 60mm, 70mm Round and 60mm Skin-Dose Optimized (SDO) applicators respectively. GafChromic EBT3+ film was embedded in the phantom midplane horizontally to measure dose distribution. Absolute dose was also measured with TLDs and an ADCL calibrated parallel-plate ion chamber placed in the film plane at field center for each applicator. The film was calibrated using 6MV x-ray beam. TLDs were calibrated in a Cs-137 source at UW-Madison calibration laboratory. Radiation leakage through the tungsten alloy shell was measured with a film wrapped around outside surface of a 60mm Round applicator. Results: Measured maximum doses at field center are consistently lower than predicated by 5.8% for TLD, 8.8% for ion chamber, and 2.6% for EBT3+ film on average, with measurement uncertainties of 2.2%, 0.3%, and 2.9% for TLD, chamber, film respectively. The total standard uncertainties for ion chamber and Gafchromic film measurement are 4.9% and 4.6% respectively[1]. The area defined by the applicator aperture was covered by 80% of maximum dose for 62mm compression thickness. When 100cGy is delivered to mid-plane with a 60mm Round applicator, surface dose ranges from 60cGy to a maximum of 145cGy, which occurs at source entrance to the applicator. Conclusion: Measured doses by all three techniques are consistently lower than predicted in our measurements. For a compression thickness of 62 mm, the field size defined by the applicator is only covered by 80% of prescribed dose. Radiation leakage of up to 145cGy was found at the source entrance of applicators.

07 ISOTOPE AND RADIATION SOURCES↗

SN 2010jl: Optical to hard X-ray observations reveal an explosion embedded in a ten solar mass cocoon

Some supernovae (SNe) may be powered by the interaction of the SN ejecta with a large amount of circumstellar matter (CSM). However, quantitative estimates of the CSM mass around such SNe are missing when the CSM material is optically thick. Specifically, current estimators are sensitive to uncertainties regarding the CSM density profile and the ejecta velocity. Here we outline a method to measure the mass of the optically thick CSM around such SNe. We present new visible-light and X-ray observations of SN 2010jl (PTF 10aaxf), including the first detection of an SN in the hard X-ray band using NuSTAR. The total radiated luminosity of SN 2010jl is extreme—at least 9 × 10{sup 50} erg. By modeling the visible-light data, we robustly show that the mass of the circumstellar material within ∼10{sup 16} cm of the progenitor of SN 2010jl was in excess of 10 M {sub ☉}. This mass was likely ejected tens of years prior to the SN explosion. Our modeling suggests that the shock velocity during shock breakout was ∼6000 km s{sup –1}, decelerating to ∼2600 km s{sup –1} about 2 yr after maximum light. Furthermore, our late-time NuSTAR and XMM spectra of the SN presumably provide the first direct measurement of SN shock velocity 2 yr after the SN maximum light—measured to be in the range of 2000-4500 km s{sup –1} if the ions and electrons are in equilibrium, and ≳ 2000 km s{sup –1} if they are not in equilibrium. This measurement is in agreement with the shock velocity predicted by our modeling of the visible-light data. Our observations also show that the average radial density distribution of the CSM roughly follows an r {sup –2} law. A possible explanation for the ≳ 10 M {sub ☉} of CSM and the wind-like profile is that they are the result of multiple pulsational pair instability events prior to the SN explosion, separated from each other by years.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibrating hypersonic turbulence flow models with the HIFiRE-1 experiment using data-driven machine-learned models.

In this paper we study the efficacy of combining machine-learning methods with projection-based model reduction techniques for creating data-driven surrogate models of computationally expensive, high-fidelity physics models. Such surrogate models are essential for many-query applications e.g., engineering design optimization and parameter estimation, where it is necessary to invoke the high-fidelity model sequentially, many times. Surrogate models are usually constructed for individual scalar quantities. However there are scenarios where a spatially varying field needs to be modeled as a function of the model’s input parameters. Here we develop a method to do so, using projections to represent spatial variability while a machine-learned model captures the dependence of the model’s response on the inputs. The method is demonstrated on modeling the heat flux and pressure on the surface of the HIFiRE-1 geometry in a Mach 7.16 turbulent flow. The surrogate model is then used to perform Bayesian estimation of freestream conditions and parameters of the SST (Shear Stress Transport) turbulence model embedded in the high-fidelity (Reynolds-Averaged Navier–Stokes) flow simulator, using shock-tunnel data. The paper provides the first-ever Bayesian calibration of a turbulence model for complex hypersonic turbulent flows. We find that the primary issues in estimating the SST model parameters are the limited information content of the heat flux and pressure measurements and the large model-form error encountered in a certain part of the flow.

42 ENGINEERING↗

The U.S. Department of Veterans' Affairs depleted uranium exposed cohort at 25 Years: Longitudinal surveillance results

Background: A small group of Gulf War I veterans wounded in depleted uranium (DU) friendly-fire incidents have been monitored for health changes in a clinical surveillance program at the Veterans Affairs Medical Center, Baltimore since 1994. Methods: During the spring of 2015, an in-patient clinical surveillance protocol was performed on 36 members of the cohort, including exposure monitoring for total and isotopic uranium concentrations in urine and a comprehensive assessment of health outcomes. Results: On-going mobilization of U from embedded fragments is evidenced by elevated urine U concentrations. The DU isotopic signature is observed principally in participants possessing embedded fragments. Those with only an inhalation exposure have lower urine U concentration and a natural isotopic signature. Conclusions: At 25 years since first exposure to DU, an aging cohort of military veterans continues to show no U-related health effects in known target organs of U toxicity. As U body burden continues to accrue from in-situ mobilization from metal fragment depots, and increases with exposure duration, critical tissue-specific U concentration thresholds may be reached, thus recommending on-going surveillance of this veteran cohort. - Highlights: • Gulf War I veterans wounded with depleted uranium are monitored for health changes. • In 2015 in-patient clinical surveillance was performed on 36 members of the cohort. • Mobilization of U from embedded fragments is evidenced by elevated U in urine. • This cohort of continues to show no U-related health effects.

54 ENVIRONMENTAL SCIENCES↗

Controlling guided modes in plasmonic metal/dielectric multilayer waveguides

We investigate the mode properties of planar dielectric aluminum-quinoline (Alq{sub 3}) multilayer waveguides comprising one single or three equally spaced embedded nanometer-thin (∼10 nm thick) Alq{sub 3}-Mg{sub 0.9}:Ag{sub 0.1} composite metal-island layers. The plasmonic waveguides were fabricated by organic molecular beam deposition. Transverse magnetic (TM) and transverse electric (TE) modes were selectively excited using the m-line method. The symmetric plasmonic TM{sub 0} mode was launched in all waveguides and—in addition—two higher order plasmonic TM{sub 1} and TM{sub 2} modes were generated in waveguides comprising three metal layers. Other TM modes have hybrid dielectric-plasmonic characters, showing an increased effective refractive index when one electric field antinode is close to a metallic layer. TM modes which have all their antinode(s) in the dielectric layers propagate essentially like dielectric modes. TE modes with antinode(s) at the position of the metal layer(s) are strongly damped while the losses are low for TE modes comprising a node at the position of the composite metal film(s). The possibility to control the effective refractive index and the losses for individual hybrid plasmonic-dielectric TM and dielectric TE modes opens new design opportunities for mode selective waveguides and TM-TE mode couplers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scalable quantum computer architecture with coupled donor-quantum dot qubits

A quantum bit computing architecture includes a plurality of single spin memory donor atoms embedded in a semiconductor layer, a plurality of quantum dots arranged with the semiconductor layer and aligned with the donor atoms, wherein a first voltage applied across at least one pair of the aligned quantum dot and donor atom controls a donor-quantum dot coupling. A method of performing quantum computing in a scalable architecture quantum computing apparatus includes arranging a pattern of single spin memory donor atoms in a semiconductor layer, forming a plurality of quantum dots arranged with the semiconductor layer and aligned with the donor atoms, applying a first voltage across at least one aligned pair of a quantum dot and donor atom to control a donor-quantum dot coupling, and applying a second voltage between one or more quantum dots to control a Heisenberg exchange J coupling between quantum dots and to cause transport of a single spin polarized electron between quantum dots.

97 MATHEMATICS AND COMPUTING↗

Large-scale continuous carbon/glass fiber additive-compression molded composites

Additive Manufacturing (AM) or 3-D printing has advanced from small-scale desktop printers to large-scale printers. Most of the present large-scale printers utilize feedstock materials in the form of pellets to create composite structures. To create structurally robust composite parts, reinforcements in the form of short fibers (carbon or glass) are often used to impart mechanical properties to the printed parts. However, poor mechanical properties in Z-direction and high porosity of pellets-based printed composites compared to composite manufactured using traditional methods are serious concerns. The authors report a combined approach in the present work, where fiber reinforced composites are printed with a high-throughput continuous fiber deposition method followed by a secondary compression molding process. A specially designed end-effector mounted on a robotic arm is used to print composite preforms. Continuous comingled fibers (Thermofiber 12K CF-PA12, Thermofiber 12K S2-PA12, and Hybrid Thermofiber 12K CF-PA12+PEEK PA6) embedded in the thermoplastic nylon matrix are printed to create composite preform plaques. The printed preforms were further compression molded (CM) using a hydraulic hot-press to create highly consolidated composite parts. The mechanical properties of the continuous fiber composites produced by this combined approach are improved significantly due to the highly aligned continuous fibers and reduced porosity. Flexural strength, flexural modulus, and tensile modulus of AM-CM Thermofiber 12K CF-PA12 UD sample were 615.37 MPa, 75.65 GPa, and 122.23 GPa, respectively.

Kumar, Vipin↗

Scenarios for Consuming Standardized Automated Demand Response Signals

Automated Demand Response (DR) programs require that Utility/ISO's deliver DR signals to participants via a machine to machine communications channel. Typically these DR signals constitute business logic information (e.g. prices and reliability/shed levels) as opposed to commands to control specific loads in the facility. At some point in the chain from the Utility/ISO to the loads in a facility, the business level information sent by the Utility/ISO must be processed and used to execute a DR strategy for the facility. This paper explores the various scenarios and types of participants that may utilize DR signals from the Utility/ISO. Specifically it explores scenarios ranging from single end user facility, to third party facility managers and DR Aggregators. In each of these scenarios it is pointed out where the DR signal sent from the Utility/ISO is processed and turned into the specific load control commands that are part of a DR strategy for a facility. The information in these signals is discussed. In some cases the DR strategy will be completely embedded in the facility while in others it may be centralized at a third party (e.g. Aggregator) and part of an aggregated set of facilities. This paper also discusses the pros and cons of the various scenarios and discusses how the Utility/ISO can use an open standardized method (e.g. Open Automated Demand Response Communication Standards) for delivering DR signals that will promote interoperability and insure that the widest range of end user facilities can participate in DR programs regardless of which scenario they belong to.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatiotemporal video-domain high-fidelity simulation and realistic visualization of full-field dynamic responses of structures by a combination of high-spatial-resolution modal model and video motion manipulations

Structures with complex geometries, material properties, and boundary conditions exhibit spatially local dynamic behaviors. A high-spatial-resolution model of the structure is thus required for high-fidelity analysis, assessment, and prediction of the dynamic phenomena of the structure. The traditional approach is to build a highly refined finite element computer model for simulating and analyzing the structural dynamic phenomena based on detailed knowledge and explicit modeling of the structural physics such as geometries, materials properties, and boundary conditions. These physics information of the structure may not be available or accurately modeled in many cases, however. In addition, the simulation on the high-spatial-resolution structural model, with a massive number of degrees of freedom and system parameters, is computationally demanding. Here this study, on a proof-of-principle basis, proposes a novel alternative approach for spatiotemporal video-domain high-fidelity simulation and realistic visualization of full-field structural dynamics by an innovative combination of the fundamentals of structural dynamic modeling and the advanced video motion manipulation techniques. Specifically, a low-modal-dimensional yet high-spatial (pixel)-resolution (as many spatial points as the pixel number on the structure in the video frame) modal model is established in the spatiotemporal video domain with full-field modal parameters first estimated from line-of-sight video measurements of the operating structure. Then in order to simulate new dynamic response of the structure subject to a new force, the force is projected onto each modal domain, and the modal response is computed by solving each individual single-degree-of-freedom system in the modal domain. The simulated modal responses are then synthesized by the full-field mode shapes using modal superposition to obtain the simulated full-field structural dynamic response. Finally, the simulated structural dynamic response is embedded into the original video, replacing the original motion of the video, thus generating a new photo-realistic, physically accurate video that enables a realistic, high-fidelity visualization/animation of the simulated full-field vibration of the structure. Laboratory experiments are conducted to validate the proposed method, and the error sources and limitations in practical implementations are also discussed. Compared with high-fidelity finite element computer model simulations of structural dynamics, the video-based simulation method removes the need to explicitly model the structure's physics. In addition, the photo-realistic, physically accurate simulated video provides a realistic visualization/animation of the full-field structural dynamic response, which was not traditionally available. Lastly, these features of the proposed method should enable a new alternative to the traditional computer-aided finite element model simulation for high-fidelity simulating and realistically visualizing full-field structural dynamics in a relatively efficient and user-friendly manner.

42 ENGINEERING↗