Search NASA⌕ Search

SEARCH · Search NASA

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

GRO J2058+42 Observations with Chandra and Detection of a Likely Optical Counterpart

GRO J2058+42 is a 195-s transient X-ray pulsar discovered in 1995 with BATSE. In 1996, RXTE located GRO J2058+42 to a 90% confidence error circle with a 4-arcminute radius. On 20 February 2004, the region including the error circle was observed with Chandra ACIS-I. No X-ray sources were detected within the error circle, however, 2 faint sources were detected in the ACIS-I field-of-view. We obtained follow-up optical observations of the brightest object, that had about 64 X-ray counts and was just 0.3 arcmin outside the error circle. The optical spectrum contained a strong H-alpha line and corresponds to an infrared object in the 2MASS catalog, indicating a Be/X-ray system. Although X-ray pulsations were undetectable due to the low count rate, this object is most likely the optical counterpart to GRO J2058+42. We present results from the Chandra observation and from the optical observations.

Wilson, Colleen A.↗

Development and Performance of a Filter Radiometer Monitor System for Integrating Sphere Sources

The NASA Goddard Space Flight Center (GSFC) Radiometric Calibration Laboratory (RCL) maintains several large integrating sphere sources covering the visible to the shortwave infrared wavelength range. Two critical, functional requirements of an integrating sphere source are short and long-term operational stability and repeatability. Monitoring the source is essential in determining the origin of systemic errors, thus increasing confidence in source performance and quantifying repeatability. If monitor data falls outside the established parameters, this could be an indication that the source requires maintenance or re-calibration against the National Institute of Science and Technology (NIST) irradiance standard. The GSFC RCL has developed a Filter Radiometer Monitoring System (FRMS) to continuously monitor the performance of its integrating sphere calibration sources in the 400 to 2400nm region. Sphere output change mechanisms include lamp aging, coating (e.g. BaSO4) deterioration, and ambient water vapor level. The Filter Radiometer Monitor System (FRMS) wavelength bands are selected to quantify changes caused by these mechanisms. The FRMS design and operation are presented, as well as data from monitoring four of the RCL s integrating sphere sources.

Ding, Leibo↗

Chlorophyll-a Algorithms for Oligotrophic Oceans: A Novel Approach Based on Three-Band Reflectance Difference

A new empirical algorithm is proposed to estimate surface chlorophyll-a concentrations (Chl) in the global ocean for Chl less than or equal to 0.25 milligrams per cubic meters (approximately 77% of the global ocean area). The algorithm is based on a color index (CI), defined as the difference between remote sensing reflectance (R(sub rs), sr(sup -1) in the green and a reference formed linearly between R(sub rs) in the blue and red. For low Chl waters, in situ data showed a tighter (and therefore better) relationship between CI and Chl than between traditional band-ratios and Chl, which was further validated using global data collected concurrently by ship-borne and SeaWiFS satellite instruments. Model simulations showed that for low Chl waters, compared with the band-ratio algorithm, the CI-based algorithm (CIA) was more tolerant to changes in chlorophyll-specific backscattering coefficient, and performed similarly for different relative contributions of non-phytoplankton absorption. Simulations using existing atmospheric correction approaches further demonstrated that the CIA was much less sensitive than band-ratio algorithms to various errors induced by instrument noise and imperfect atmospheric correction (including sun glint and whitecap corrections). Image and time-series analyses of SeaWiFS and MODIS/Aqua data also showed improved performance in terms of reduced image noise, more coherent spatial and temporal patterns, and consistency between the two sensors. The reduction in noise and other errors is particularly useful to improve the detection of various ocean features such as eddies. Preliminary tests over MERIS and CZCS data indicate that the new approach should be generally applicable to all existing and future ocean color instruments.

Hu, Chuanmin↗

Project Report: Reducing Color Rivalry in Imagery for Conjugated Multiple Bandpass Filter Based Stereo Endoscopy

A pair of conjugated multiple bandpass filters (CMBF) can be used to create spatially separated pupils in a traditional lens and imaging sensor system allowing for the passive capture of stereo video. This method is especially useful for surgical endoscopy where smaller cameras are needed to provide ample room for manipulating tools while also granting improved visualizations of scene depth. The significant issue in this process is that, due to the complimentary nature of the filters, the colors seen through each filter do not match each other, and also differ from colors as seen under a white illumination source. A color correction model was implemented that included optimized filter selection, such that the degree of necessary post-processing correction was minimized, and a chromatic adaptation transformation that attempted to fix the imaged colors tristimulus indices based on the principle of color constancy. Due to fabrication constraints, only dual bandpass filters were feasible. The theoretical average color error after correction between these filters was still above the fusion limit meaning that rivalry conditions are possible during viewing. This error can be minimized further by designing the filters for a subset of colors corresponding to specific working environments.

conjugated multiple bandpass filters (CMBF)↗

Estimating Species-Specific Leaf Area Index and Basal Area Using Optical and SAR Remote Sensing Data in Acadian Mixed Spruce-Fir Forests, USA

This study combined Sentinel-1 synthetic aperture radar (SAR), Sentinel-2 multispectral, and site variable datasets to model leaf area index (LAI) and basal area per ha (BAPH) of two economically important tree species in Northeast, USA; red spruce (Picea rubens Sarg.; RS), and balsam fir (Abies balsamea (L.) Mill.; BF). We used Random Forest (RF), and Multi-Layer Perceptron (MLP) algorithms for LAI and BAPH modeling. The results showed that RF outperformed MLP by reducing the normalized root mean square error (nRMSE) by 0.01 and 0.06 for LAI and BAPH, respectively. The final variables selected for modeling of both LAI and BAPH indicated the superiority of Sentinel-2 variables over the Sentinel-1 SAR with minor contributions of site variables (mainly elevation). The red-edge spectral vegetation indices played a significant role in both LAI and BAPH estimation. We attained the lowest nRMSEs of 0.12, and 0.16 for the final LAI model of RS, and BF, respectively using Sentinel-2 and site variables. The lowest nRMSE for both RS and BF BAPH models was 0.12. As RS and BF are the primary host species for a cyclically occurring and most destructive pest of the region, eastern spruce budworm (Choristoneura fumiferana; SBW), these estimations will be useful to evaluate SBW dynamics in the region.

Forest inventory↗

Assessment of Control Algorithms for Mars Entry Vehicles With Flap-Based Trajectory Control Under Uncertainty

Flap-based steering systems on blunt-body entry vehicles may improve flight performance relative to heritage bank-angle steering systems. Successful implementation of articulating aerodynamic flaps on a hypersonic entry vehicle requires an active control system to map angle of attack and sidelip angle commands to flap deflection commands. Here, a successive-linearization model prective control algorithm, as a linear quadratic regulator, are formulated, designed, and assessed to address this multiple input multiple output control problem. These two control algorithms are assessed under uncertainty in Monte Carlo simulations for various control profiles and vehicle configurations. Results indicate that while both control algorithms provide successful command tracking under uncertainty, the model predictive controller provides a lower mean and integral error, as well as greater robustness, relative to the linear-quadratic regulator.

Daniel L Engel↗

Geometric accuracy of LANDSAT-4 MSS image data

Analyses of the LANDSAT-4 MSS image data of North Georgia provided by the EDC in CCT-p formats reveal that errors of approximately + or - 30 m in the raw data can be reduced to about + or - 55 m based on rectification procedures involving the use of 20 to 30 well-distributed GCPs and 2nd or 3rd degree polynomial equations. Higher order polynomials do not appear to improve the rectification accuracy. A subscene area of 256 x 256 pixels was rectified with a 1st degree polynomial to yield an RMSE sub xy value of + or - 40 m, indicating that USGS 1:24,000 scale quadrangle-sized areas of LANDSAT-4 data can be fitted to a map base with relatively few control points and simple equations. The errors in the rectification process are caused by the spatial resolution of the MSS data, by errors in the maps and GCP digitizing process, and by displacements caused by terrain relief. Overall, due to the improved pointing and attitude control of the spacecraft, the geometric quality of the LANDSAT-4 MSS data appears much improved over that of LANDSATS -1, -2 and -3.

Welch, R.↗

Geometric Accuracy of LANDSAT-4 MSS Image Data

Analyses of the LANDSAT-4 MSS image data of North Georgia provided by the EDC in CTT-p formats reveal that errors of approximately + or - 30 m in the raw data can be reduced to about + or - 55 m based on rectification procedures involving the use of 20 to 30 well-distributed GCPs and 2nd or 3rd degree polynomial equations. Higher order polynomials do not appear to improve the rectification accuracy. A subscene area of 256 by 256 pixels was rectified with a 1st degree polynomial to yield an RMSE sub xy value of + or - 40 m, indicating that USGS 1:24,000 scale quadrangle-sized areas of LANDSAT-4 data can be fitted to a map base with relatively few control points and simple equations. The errors in the rectification process are caused by the spatial resolution of the MSS data, by errors in the maps and GCP digitizing process, and by displacements caused by terrain relief. Overall, due to the improved pointing and attitude control of the spacecraft, the geometric quality of the LANDSAT-4 MSS data appears much improved over that of LANDSAT-1, -2 AND -3.

Welch, R.↗

Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy

Purpose: To clinically evaluate an iterative metal artifact reduction (IMAR) algorithm prototype in the radiation oncology clinic setting by testing for accuracy in CT number retrieval, relative dosimetric changes in regions affected by artifacts, and improvements in anatomical and shape conspicuity of corrected images. Methods: A phantom with known material inserts was scanned in the presence/absence of metal with different configurations of placement and sizes. The relative change in CT numbers from the reference data (CT with no metal) was analyzed. The CT studies were also used for dosimetric tests where dose distributions from both photon and proton beams were calculated. Dose differences and gamma analysis were calculated to quantify the relative changes between doses calculated on the different CT studies. Data from eight patients (all different treatment sites) were also used to quantify the differences between dose distributions before and after correction with IMAR, with no reference standard. A ranking experiment was also conducted to analyze the relative confidence of physicians delineating anatomy in the near vicinity of the metal implants. Results: IMAR corrected images proved to accurately retrieve CT numbers in the phantom study, independent of metal insert configuration, size of the metal, and acquisition energy. For plastic water, the mean difference between corrected images and reference images was −1.3 HU across all scenarios (N = 37) with a 90% confidence interval of [−2.4, −0.2] HU. While deviations were relatively higher in images with more metal content, IMAR was able to effectively correct the CT numbers independent of the quantity of metal. Residual errors in the CT numbers as well as some induced by the correction algorithm were found in the IMAR corrected images. However, the dose distributions calculated on IMAR corrected images were closer to the reference data in phantom studies. Relative spatial difference in the dose distributions in the regions affected by the metal artifacts was also observed in patient data. However, in absence of a reference ground truth (CT set without metal inserts), these differences should not be interpreted as improvement/deterioration of the accuracy of calculated dose. With limited data presented, it was observed that proton dosimetry was affected more than photons as expected. Physicians were significantly more confident contouring anatomy in the regions affected by artifacts. While site specific preferences were detected, all indicated that they would consistently use IMAR corrected images. Conclusions: IMAR correction algorithm could be readily implemented in an existing clinical workflow upon commercial release. While residual errors still exist in IMAR corrected images, these images present with better overall conspicuity of the patient/phantom geometry and offer more accurate CT numbers for improved local dosimetry. The variety of different scenarios included herein attest to the utility of the evaluated IMAR for a wide range of radiotherapy clinical scenarios.

60 APPLIED LIFE SCIENCES↗

A General Framework for Error-controlled Unstructured Scientific Data Compression

Data compression plays a key role in reducing storage and I/O costs. Traditional lossy methods primarily target data on rectilinear grids and cannot leverage the spatial coherence in unstructured mesh data, leading to suboptimal compression ratios. We present a multi-component, error-bounded compression framework designed to enhance the compression of floating-point unstructured mesh data, which is common in scientific applications. Our approach involves interpolating mesh data onto a rectilinear grid and then separately compressing the grid interpolation and the interpolation residuals. This method is general, independent of mesh types and typologies, and can be seamlessly integrated with existing lossy compressors for improved performance. We evaluated our framework across twelve variables from two synthetic datasets and two real-world simulation datasets. The results indicate that the multi-component framework consistently outperforms state-of-the-art lossy compressors on unstructured data, achieving, on average, a 2.3 − 3.5× improvement in compression ratios, with error bounds ranging from 1 × 10 the −6 to 1×10−2. We further investigate impact of hyperparameters, such as grid spacing and error allocation, to deliver optimal compression ratios in diverse datasets.

Gong, Qian↗

Benefits of Ka-band GaN MMIC High Power Amplifiers With Wide Bandwidth and High Spectral/Power Added Efficiencies for Cognitive Radio Platforms

A cognitive radio on a future NASA near-Earth spacecraft will be capable of sensing its environment and dynamically adapting its operating parameters to provide the desired SATCOM service to the mission. A key component that can enable this type of operation is a high-power amplifier (HPA) that resides on the radio platform. In this paper, we present the RF performance characteristics of a Ka-band gallium nitride (GaN) monolithic microwave integrated circuit (MMIC) based HPA for cognitive radio platforms. These characteristics include the output power, gain, power added efficiency (PAE), RMS error vector magnitude (EVM), spectral efficiency, 3rd-order intermodulation distortion (IMD) products, spectrum, spectral regrowth, noise figure (NF), and phase noise. The data presented indicates that the HPA meets NTIA, military, and commercial spectral mask requirements. In addition, we discuss the benefits offered by the above performance characteristics toward the design and implementation of a cognitive radio platform. Furthermore, as examples, we discuss three potential use cases that apply artificial intelligence (AI) and machine learning (ML) techniques and exploit the performance characteristics discussed above to provide a knowledge-based cognitive radio platform design for SATCOM. Thus, cognitive radios with performance flexibility can enable roaming and provide seamless interoperability autonomously in the future between NASA, commercial, and other space networks owned by U.S. government agencies.

Gallium nitride↗

Benefits of Ka-band GaN MMIC High Power Amplifiers With Wide Bandwidth and High Spectral/Power Added Efficiencies for Cognitive Radio Platforms

A cognitive radio on a future NASA near-Earth spacecraft will be capable of sensing its environment and dynamically adapting its operating parameters to provide the desired SATCOM service to the mission. A key component that can enable this type of operation is a high-power amplifier (HPA) that resides on the radio platform. In this report, we present the RF performance characteristics of a Ka-band gallium nitride (GaN) monolithic microwave integrated circuit (MMIC) based HPA for cognitive radio platforms. These characteristics include the output power, gain, power added efficiency (PAE), RMS error vector magnitude (EVM), spectral efficiency, 3rdorder intermodulation distortion (IMD) products, spectrum, spectral regrowth, noise figure (NF), phase noise, and group delay. The data presented indicates that the HPA meets NTIA, military, and commercial spectral mask requirements. In addition, we discuss the benefits offered by the above performance characteristics toward the design and implementation of a cognitive radio platform. Furthermore, as examples, we discuss three potential use cases that apply artificial intelligence (AI) and machine learning (ML) techniques and exploit the performance characteristics discussed above to provide a knowledge-based cognitive radio platform design for SATCOM. Thus, cognitive radios with performance flexibility can enable roaming and provide seamless interoperability autonomously in the future between NASA, commercial, and other space networks owned by U.S. government agencies.

Gallium nitride↗

On the validity of the basis set superposition error and complete basis set limit extrapolations for the binding energy of the formic acid dimer

We report the variation of the binding energy of the Formic Acid Dimer with the size of the basis set at the Coupled Cluster with iterative Singles, Doubles and perturbatively connected Triple replacements [CCSD(T)] level of theory, estimate the Complete Basis Set (CBS) limit, and examine the validity of the Basis Set Superposition Error (BSSE)-correction for this quantity that was previously challenged by Kalescky, Kraka, and Cremer (KKC) [J. Chem. Phys. 140, 084315 (2014)]. Our results indicate that the BSSE correction, including terms that account for the substantial geometry change of the monomers due to the formation of two strong hydrogen bonds in the dimer, is indeed valid for obtaining accurate estimates for the binding energy of this system as it exhibits the expected decrease with increasing basis set size. We attribute the discrepancy between our current results and those of KKC to their use of a valence basis set in conjunction with the correlation of all electrons (i.e., including the 1s of C and O). We further show that the use of a core-valence set in conjunction with all electron correlation converges faster to the CBS limit as the BSSE correction is less than half than the valence electron/valence basis set case. The uncorrected and BSSE-corrected binding energies were found to produce the same (within 0.1 kcal/mol) CBS limits. We obtain CCSD(T)/CBS best estimates for D{sub e} = − 16.1 ± 0.1 kcal/mol and for D{sub 0} = − 14.3 ± 0.1 kcal/mol, the later in excellent agreement with the experimental value of −14.22 ± 0.12 kcal/mol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of importance of lateral acceleration derivatives in extraction of lateral-directional derivatives at high angles of attack

A theoretical investigation was conducted to determine the importance of the lateral acceleration (beta) derivatives in the extraction of lateral-directional stability derivatives for swept wing airplanes at high angles of attack. Representative values of lateral acceleration derivatives in yaw and roll (Cn beta and Cl beta) were used in a computer program to generate representative flight motions at several angles of attack and altitudes. The computer-generated motions were then subjected to a parameter identification process based on a modified Newton-Raphson method. Two identification techniques were evaluated, one which included the beta derivatives and one which neglected them. The results of the study indicate that omission of the beta derivatives from mathematical models used in the derivative-extraction techniques can produce erroneous values for the lateral-directional stability derivatives particularly at high angles of attack, where the beta derivatives are large. The largest errors occur in the dynamic derivatives, but large errors may also occur in the static derivatives for cases in which the beta derivatives have large effects on the flight motions of the airplane. In addition, the resulting identified mathematical models provide poor motion prediction as well as erroneous predictions of dynamic modal characteristics. These results strongly indicate that the effects of beta derivatives should be considered in any attempt to extract lateral-directional aerodynamic parameters at high angles of attack.

Nguyen, L. T.↗

Communication indices of crew coordination

The relationship between communication patterns and performance in 10 two-person flightcrews is explored with the aim of identifying speech variations which differentiate low- and high-error full mission simulator flights. Verbal data, transcribed from the videotaped performances, are treated as interactive sequences of speech events in which statements spoken by one crewmember are considered within the context of the other crewmember's prior and subsequent speech. Specific speech patterns characterized each crew, but the overriding findings included: a) marked homogeneity of patterns characterizing low-error crews, interpreted as the adoption of a standard form of communicating, and b) heterogeneity of patterns characterizing high-error crews, interpreted as the relative absence of a conventionalized form. Because conventions are regularities which confirm the expectations of those involved, predictability of crewmember behavior should be greater when standard conventions are followed. We conclude that such a practice can facilitate the coordination process and enhance crew performance.

Aerospace Medicine↗

Evaluation of hydrologic components of community land model 4 and bias identification

Runoff and soil moisture are two key components of the global hydrologic cycle that should be validated at local to global scales in Earth System Models (ESMs) used for climate projection. Here, we have evaluated the runoff and surface soil moisture output by the Community Climate System Model (CCSM) along with 8 other models from the Coupled Model Intercomparison Project (CMIP5) repository using satellite soil moisture observations and stream gauge corrected runoff products. A series of Community Land Model (CLM) runs forced by reanalysis and coupled model outputs was also performed to identify atmospheric drivers of biases and uncertainties in the CCSM. Results indicate that surface soil moisture simulations tend to be positively biased in high latitude areas by most selected CMIP5 models except CCSM, FGOALS, and BCC, which share similar land surface model code. With the exception of GISS, runoff simulations by all selected CMIP5 models were overestimated in mountain ranges and in most of the Arctic region. In general, positive biases in CCSM soil moisture and runoff due to precipitation input error were offset by negative biases induced by temperature input error. Excluding the impact from atmosphere modeling, the global mean of seasonal surface moisture oscillation was out of phase compared to observations in many years during 1985–2004. The CLM also underestimated runoff in the Amazon, central Africa, and south Asia, where soils all have high clay content. We hypothesize that lack of a macropore flow mechanism is partially responsible for this underestimation. However, runoff was overestimated in the areas covered by volcanic ash soils (i.e., Andisols), which might be associated with poor soil porosity representation in CLM. Finally, our results indicate that CCSM predictability of hydrology could be improved by addressing the compensating errors associated with precipitation and temperature and updating the CLM soil representation.

54 ENVIRONMENTAL SCIENCES↗

Postmortem validation of breast density using dual-energy mammography

Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.

60 APPLIED LIFE SCIENCES↗

Waste Form Release Data Package for the 2005 Integrated Disposal Facility Performance Assessment. Erratum

Please insert erratum page in report PNNL-14805. This erratum serves to correct the K g (Glass apparent equilibrium constant based on the SiO 2 (aq) activity) values affected by a calculation error for glasses LAWA44, LAWB45 and LAWC22. The error was first identified by Papathanassiu et al. (2011). The K g values were corrected by Freedman et al. (2015) by multiplying the erroneous K g values by approx. 3.4. As indicated in Freedman et al. (2015), this 3.4 factor originates from the erroneous use of the molecular weight of H 4 SiO 4 (96.114 g·mol –1 ) instead of the molecular weight for Si (28.086 g·mol –1 ).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗