Reining in an Agentic Harness for High Energy Physics

Agentic systems now address tasks across theoretical, phenomenological, and experimental high energy physics (HEP), but their scientific capabilities remain difficult to reuse across different large language models, providers, and harnesses. We argue that stable parts of these workflows should be promoted into versioned scientific operations and exposed through common protocols. Existing general-purpose harnesses can then be specialized for HEP through task-specific sets of tools and skills, while community-maintained registries would make these capabilities discoverable and citable. We identify mismatches in conventions, assumptions, and domains of validity among independently developed operations as a potential obstacle to their composition, and discuss machine-readable scientific contracts as one possible solution. These design principles and evaluation guidelines provide a near-term path toward a portable and community-maintained agentic harness for HEP.

Menzo, Tony [Alabama U.; Fermilab] (ORCID:00000002↗

Detailed Laboratory Evaluation of Electric Demand Load Shifting Potential of Controlled Heat Pump Water Heaters

The demand profile management of electric end uses is vital research for utilities and policymakers planning greenhouse gas emission reductions. In this study, detailed laboratory research was conducted on the load shifting potential of 4 grid-connected HPWHs and one electric resistance water heaters (ERWH). The testing applied different CTA-2045 shed and critical peak command designs under three water draw profiles. Highly-controlled laboratory experiments were conducted in Florida. One of the four HPWHs was a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load-up above tank setpoint. A three-hour morning (6 – 9 AM) and four-hour evening curtailment (4 – 8 PM) were defined as the shed or critical peak periods reflecting high-value control periods for utility coincident load for system-wide electric demand reductions. Tests were performed under baseline conditions (no load shift) and under varied load-shifting schemes, including load up and advanced load up, ahead of shed and critical peak commands. Data were collected from December 2020 – February 2022 in the laboratory and compared with field experiments in Florida and the Pacific Northwest. Grid-connected HPWHs were found to reduce peak demand by up to 0.47 kW compared to uncontrolled HPWH units, depending on time of day, control scheme, draw profile, and temperature cluster. The load up strategy demonstrated the ability of all units to utilize heat pump mode for extended periods ahead of peak events. Demand reductions for the HPWHs were much larger when compared with the ERWH— up to 1.64 kW with large hot water draws in winter.

Fenaughty, Karen↗

Virtual monoenergetic reconstruction of contrast-enhanced CT scans of the abdomen and pelvis at 40 keV improves the detection of peritoneal metastatic deposits

Purpose: To evaluate the role of virtual monoenergetic imaging (VMI) in the detection of peritoneal metastatic disease in contrast-enhanced computed tomography (CT) of the abdomen and pelvis and to compare this technique to the conventional 120 kV mixed dataset. Materials and methods: Institutional review board approval was obtained with no informed consent required for this retrospective analysis. 43 consecutive patients with histopathologically confirmed peritoneal disease were scanned using a standard protocol on a 128-section dual-source, dual-energy CT system (100/140 keV). Scans were retrospectively reconstructed at VMI energy levels from 40–110 keV in 10 keV increments and were analyzed both quantitatively and qualitatively. CNR values for peritoneal metastatic deposits were recorded using region of interest (ROI) analysis at each energy level for all VMI datasets. Subjective analysis was performed by two independent fellowship-trained readers with combined experience of greater than 15 years. Qualitative parameters included diagnostic acceptability, subjective noise, and contrast resolution and confidence. Results: The contrast-to-noise ratios (CNRs) for peritoneal metastatic deposits at the different VMI energy levels were compared using a one-way ANOVA with Tukey Post Test, and the optimal CNR was observed at 40 keV (p < 0.0001). Qualitative parameters were compared using a Paired T Test. Subjective noise, diagnostic acceptability, and contrast resolution was significantly better on the conventional images, but readers reported increased confidence on VMI at 40 keV (p < 0.001). Conclusion: VMI reconstruction of contrast-enhanced dual-energy CT scans of the abdomen and pelvis at 40 keV maximizes the conspicuity of metastatic peritoneal deposits and improves radiologists’ diagnostic confidence compared with conventional CT images. We recommend using virtual monoenergetic datasets at 40 keV as a tool for improving the detection of these lesions in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of alkali-soluble lignin on purified core cellulase and hemicellulase activities during hydrolysis of extractive ammonia-pretreated lignocellulosic biomass

Removing alkali-soluble lignin using extractive ammonia (EA) pretreatment of corn stover (CS) is known to improve biomass conversion efficiency during enzymatic hydrolysis. In this study, we investigated the effect of alkali-soluble lignin on six purified core glycosyl hydrolases and their enzyme synergies, adopting 31 enzyme combinations derived by a five-component simplex centroid model, during EA-CS hydrolysis. Hydrolysis experiment was carried out using EA-CS(-) (approx. 40% lignin removed during EA pretreatment) and EA-CS(+) (where no lignin was extracted). Enzymatic hydrolysis experiments were done at three different enzyme mass loadings (7.5, 15 and 30 mg protein g -1 glucan), using a previously developed high-throughput microplate-based protocol, and the sugar yields of glucose and xylose were detected. The optimal enzyme combinations (based on % protein mass loading) of six core glycosyl hydrolases for EA-CS(-) and EA-CS(+) were determined that gave high sugar conversion. The inhibition of lignin on optimal enzyme ratios was studied, by adding fixed amount of alkali-soluble lignin fractions to EA-CS(-), and pure Avicel, beechwood xylan and evaluating their sugar conversion. The optimal enzyme ratios that gave higher sugar conversion for EA-CS(-) were CBH I: 27.2–28.2%, CBH II: 18.2–22.2%, EG I: 29.2–34.3%, EX: 9.0–14.1%, βX: 7.2–10.2%, βG: 1.0–5.0% (at 7.5–30 mg g -1 protein mass loading). Endoglucanase was inhibited to a greater extent than other core cellulases and xylanases by lignin during enzyme hydrolysis. We also found that alkali-soluble lignin inhibits cellulase more strongly than hemicellulase during the course of enzyme hydrolysis.

09 BIOMASS FUELS↗

Building Scalable PGAS Communication Subsystem on Blue Gene/Q

This paper presents a design of scalable Partitioned Global Address Space (PGAS) communication subsystems on recently proposed Blue Gene/Q architecture. The proposed design provides an in-depth modeling of communication infrastructure using Parallel Active Messaging Interface (PAMI). The communication infrastructure is used to design time-space efficient communication protocols for frequently used data-types (contiguous, uniformly non-contiguous) using Remote Direct Memory Access (RDMA) get/put primitives. The proposed design accelerates load balance counters by using asynchronous threads, which are required due to the missing network hardware support for Atomic Memory Operations (AMOs). Under the proposed design, the synchronization traffic is reduced by tracking conflicting memory accesses in distributed space with slightly increment in space complexity. An evaluation with simple communication benchmarks show a adjacent node get latency of 2.89$\mu$s and peak bandwidth of 1775 MB/s resulting in $\approx$ 99\% communication efficiency.The evaluation shows a reduction in the execution time by up to 30\% for NWChem self consistent field calculation on 4096 processes using the proposed asynchronous thread based design.

Vishnu, Abhinav↗

A Study of Cost-Saving Potential of Load Flexibility Measures in Grid-Interactive Multifamily Buildings

With recent advances in smart technologies, more and more smart devices are penetrating the residential and commercial buildings market. The introduction of these smart devices is also helping IoT companies emerge with load aggregator roles in the sector. With more utility companies on the track of supporting OpenADR protocols, the aggregators could play a significant role in providing load flexibilities by automatically responding to demand response (DR) events and coordinating load flexibility measures between customers. This would benefit utility companies by reducing stress on the grid during critical peak demand hours as well as customers by allowing them to utilize utility rate structures advantageous to those able to reduce electric usage during high-demand hours. This study evaluates cost and energy savings from adopting multiple load flexibility measures in multifamily buildings. Combinations of different load flexibility measures, including space temperature floating, light dimming, automatic window shading, and water heater temperature floating, are considered. The simulations are performed using OpenStudio®, an open-source U.S. Department of Energy (DOE) simulation platform. For the case study, we used a midrise apartment building with weather conditions from Denver, Colorado. To compare climate zone differences, simulations were also performed for Los Angeles, California, and Chicago, Illinois. Initial results indicate that the application of automated load flexibility measures without careful consideration of dispatching strategies and DR program enrollments could significantly affect the savings. To get meaningful cost savings, aggregators need to encourage tenant awareness to curtail energy usage through occupant behavior in addition to dispatching automatic load flexibility measures. The outcomes from this study are believed to help load aggregators understand the risks and benefits of load flexibility opportunities.

building energy modeling↗

Bridging Control and Deployment: A Cross-Layer Analysis of Scalable Building Cluster Control

Building cluster control has emerged as a promising approach for enabling flexible and coordinated operation of distributed building systems, yet its transition from pilot demonstrations to routine grid-interactive operation remains limited. This paper argues that this gap cannot be explained by control algorithms alone. Instead, it arises from interacting barriers in communication infrastructure, data and semantic interoperability, uncertainty management, stakeholder participation, market design, and policy support. Accordingly, the paper reviews both technical and non-technical barriers to building cluster control. Technical challenges include heterogeneous devices and protocols, communication latency and reliability, distributed decision-making, and uncertainty propagation across aggregated loads. Non-technical barriers include user participation, stakeholder coordination, incentive allocation, and data governance. Existing solution approaches are synthesized, including semantic interoperability frameworks, edge and hierarchical communication architectures, distributed and transactive control strategies, uncertainty-aware optimization, policy mechanisms, and market reforms. Based on this analysis, two research directions are identified: testing infrastructures that can evaluate control performance under realistic multi-building conditions, and abstraction methods that allow building clusters to interact with other energy sectors through standardized flexibility representations. Overall, the paper provides a structured review of how building cluster control can move from isolated demonstrations toward reproducible, market-compatible, and grid-relevant implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Importance of dose-rate and cell proliferation in the evaluation of biological experimental results

The nuclei of cells within the bodies of astronauts traveling on extended missions outside the geomagnetosphere will experience single traversals of particles with high Linear Energy Transfer (LET) (e.g., one iron ion per one hundred years, on average) superimposed on a background of tracks with low LET (approximately one proton every two to three days, and one helium ion per month). In addition, some cell populations within the body will be proliferating, thus possibly providing increasing numbers of cells with 'initiated' targets for subsequent radiation hits. These temporal characteristics are not generally reproduced in laboratory experimental protocols. Implications of the differences in the temporal patterns of radiation delivery between conventionally designed radiation biology experiments and the pattern to be experienced in space are examined and the importance of dose-rate and cell proliferation are pointed out in the context of radiation risk assessment on long mission in space.

Curtis, S. B.↗

Evaluation of vicarious calibration for airborne sensors using RadCalNet

Vicarious calibration approaches using in-situ measurements are key techniques applied to on-orbit remote sensors. The in-situ measurements have advantages in terms of traceability and quantifiable accuracy that make them ideal for inter-consistency studies of on-orbit sensors. The Committee on Earth Observation Satellites Working Group on Calibration and Validation Infrared Visible Optical Sensors initiated the Radiometric Calibration Network (RadCalNet) to provide automated surface and top-of-atmosphere (TOA) reflectance data from multiple participating ground sites to the worldwide user community. RadCalNet standardizes protocols for collecting data, processes TOA reflectance, and provides International System of Units traceable uncertainty budgets for the five currently operating sites. RadCalNet data from the Railroad Valley Playa, Nevada, site was used to provide an SI-traceable, absolute radiometric calibration of the Enhanced MODIS Airborne Simulator as part of an overflight of opportunity during the FIREX-AQ campaign. The results shown here demonstrate the utility of RadCalNet data for absolute radiometric calibration of airborne imagers making flights of opportunity without the need for coordination with a field validation team.

Sensors↗

Optimum Full Information, Unlimited Complexity, Invariant and Minimax Clock Skew and Offset Estimators for IEEE 1588

This paper presents the problem of clock skew and offset estimation for the IEEE 1588 precision time protocol. Built on the classical two-way message exchange scheme, IEEE 1588 is a prominent synchronization protocol for packet switched networks. Because of the presence of random queuing delays in a packet switched network, the joint recovery of clock skew and offset from the received packet timestamps can be viewed as a statistical estimation problem. Recently, assuming perfect clock skew information, minimax optimum clock offset estimators were developed for IEEE 1588. Building on this work, we first develop joint optimum invariant clock skew and offset estimators for IEEE 1588 for known queuing delay statistics and unlimited computational complexity. We then show the developed estimators are minimax optimum, i.e., these estimators minimize the maximum skew normalized mean square estimation error over all possible values of the unknown parameters. Minimax optimum estimators that utilize information from past timestamps to improve accuracy are also introduced. The developed optimum estimators provide useful fundamental limits for evaluating the performance of clock skew and offset estimation schemes. These performance limits can aid system designers to develop algorithms with the desired computational complexity that achieve performance close to the performance of the optimum estimators. If a designer finds an approach with a complexity they find acceptable and which provides performance close to the optimum performance, they can use it and know they have near optimum performance. This is precisely the approach used in communications when comparing to capacity.

Cellular networks↗

Understanding slurry formulations to guide solution-processing of solid electrolytes

Scalable processing of thin solid electrolytes is crucial for engineering solid-state batteries with practical energy densities. To leverage existing battery production infrastructure, pathways for solution processing of solid electrolyte films must be investigated. Here, roll-to-roll compatible film preparation of aluminum-doped lithium lanthanum zirconate oxide was studied. Four slurry configurations accounting for different solvent properties and solid loadings were evaluated to investigate the ternary interactions within the dispersions. Rheological and coating stability analyses were carried out on the processed slurries. The analysis and characterization indicated that improved component interactions within the ethanol/toluene system result in homogenized distribution of the particles, binder, and plasticizer, and enable the extraction of free-standing thin films with thicknesses of 20 μm and large area (>15 in. 2 ). The drawbacks and opportunities of several protocols for high temperature sintering of the dried green films were investigated. This study highlights the importance of engineering dispersions during the development of processing protocols for solid electrolytes and provides guidelines for the best practices that can be leveraged for solution processing–based fabrications for a wide range of solid electrolyte materials.

25 ENERGY STORAGE↗

High-accuracy extrapolated ab initio thermochemistry. IV. A modified recipe for computational efficiency

A number of economical modifications to the high-accuracy extrapolated ab initio thermochemistry (HEAT) model chemistry are evaluated. The two resulting schemes, designated as mHEAT and mHEAT+, are designed for efficient and pragmatic evaluation of molecular energies in systems somewhat larger than can be practically studied by the unapproximated HEAT scheme. It is found that mHEAT+ produces heats of formation with nearly subchemical ± 1 kJ/mol) accuracy at a substantially reduced cost relative to the full scheme. Total atomization energies calculated using the new thermochemical recipes are compared to the results of the HEAT-345(Q) model chemistry, and enthalpies of formation for the three protocols are also compared to Active Thermochemical Tables. Finally, a small selection of transition states is studied using mHEAT and mHEAT+, which illuminates some interesting features of reaction barriers and serves as an initial benchmark of the performance of these model chemistries for chemical kinetics applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Case Study: Iran, Islam, the NPT, and the Bomb

The goals of this case study are: (1) To examine the correlation between Iran's nuclear program and clerical statements; (2) To evaluate the importance of these statements; (3) To understand the relationship between policy and fatwas (Islamic decrees); (4) To address the issue of a 'nuclear fatwa'; and (5) To examine how, if at all, Sharia (Islamic law) has influenced Iran's actions or inactions with respect to the Non-Proliferation Treaty (NPT), the International Atomic Energy Agency (IAEA), and Iran's adherence to its IAEA Safeguards Agreements and the Additional Protocol. The Islamic Republic of Iran (hereinafter Iran) is one of two theocracies in the world, the second being Vatican City. Iran's government derives its constitutional, moral, and political legitimacy from Islam. As a result of this theocratic culture, rules are set and interpreted with a much different calibrator than that of the Western world. Islam affects all aspects of Iranian life. This is further complicated by the fact that Islam is not a nationalistic faith, in that many people all over the world believe in and adhere to Islamic principles. As a result, a political system that derives much of its fervor from being nationalistic is caught between two worlds, one within the land boundaries of Iran and the other within a faith that transcends boundaries. Thus, any understanding of Islamic law must first be understood within this delicate balance of nationalism and transcendence. Iran has found itself on the international stage concerning its nuclear program. Because Iran is a theocratic state, it is imperative to examine its political moves, speeches, rights, and obligations through the lens of Islam. This study will examine how Islam plays a role in Iran's dealing with the International Atomic Energy Agency (IAEA), its understanding of the Nuclear Non-Proliferation Treaty (NPT), including parties obligations under Safeguards Agreements and the Additional Protocol, and also provide a recommendation on how to move forward in dealings with Iran based in part on an understanding of Islamic principles.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of Waste Heat Recovery and Utilization from Residential Appliances and Fixtures

Executive Summary In every home irrespective of its size, location, age, or efficiency, heat in the form of drainwater or dryer exhaust is wasted. Although from a waste stream, this energy has the potential for being captured, possibly stored, and then reused for preheating hot water or air thereby saving operating costs to the homeowner. In applications such as a shower and possibly a dryer, waste heat is produced at the same time as energy is used, so that a heat exchanger to capture the waste energy and return it to the supply is all that is needed. In other applications such as capturing the energy in drainwater from a tub, dishwasher, or washing machine, the availability of waste heat might not coincide with an immediate use for energy, and consequently a heat exchanger system with heat storage capacity (i.e. a regenerator) would be necessary. This study describes a two-house experimental evaluation of a system designed to capture waste heat from the shower, dishwasher clothes washer and dryer, and to use this waste heat to offset some of the hot water energy needs of the house. Although each house was unoccupied, they were fitted with equipment that would completely simulate the heat loads and behavior of human occupants including operating the appliances and fixtures on a demand schedule identical to Building American protocol (Hendron, 2009). The heat recovery system combined (1) a gravity-film heat exchanger (GFX) installed in a vertical section of drainline, (2) a heat exchanger for capturing dryer exhaust heat, (3) a preheat tank for storing the captured heat, and (4) a small recirculation pump and controls, so that the system could be operated anytime that waste heat from the shower, dishwasher, clothes washer and dryer, and in any combination was produced. The study found capturing energy from the dishwasher and clothes washer to be a challenge since those two appliances dump waste water over a short time interval. Controls based on the status of the dump valve on these two appliances would have eliminated uncertainty in knowing when waste water was flowing and the recovery system operated. The study also suggested that capture of dryer exhaust heat to heat incoming air to the dryer should be examined as an alternative to using drying exhaust energy for water heating. The study found that over a 6-week test period, the system in each house was able to recover on average approximately 3000 W-h of waste heat daily from these appliance and showers with slightly less on simulated weekdays and slightly more on simulated weekends which were heavy wash/dry days. Most of these energy savings were due to the shower/GFX operation, and the least savings were for the dishwasher/GFX operation. Overall, the value of the 3000 W-h of displaced energy would have been $0.27/day based on an electricity price of $.09/kWh. Although small for today s convention house, these savings are significant for a home designed to approach maximum affordable efficiency where daily operating costs for the whole house are less than a dollar per day. In 2010 the actual measured cost of energy in one of the simulated occupancy houses which waste heat recovery testing was undertaken was $0.77/day.

Tomlinson, John J.↗

Simulation of 4D RNAV in the terminal area

A terminal area control concept based on 4D RNAV (3D plus time) has been developed to take full advantage of STOL aircrafts' unique performance capabilities. The 4D RNAV concept involves an airborne system, a ground system and a protocol for information exchange between aircraft and ground. The function of the airborne system is to synthesize the curved three dimensional (3D) flight path, to predict and control the landing time (4D) and to generate flight director or autopilot commands. The airborne system assumes the ground system will specify the 3D path and assign a conflict-free landing time. A real time simulation of this concept has been developed to evaluate its effectiveness for terminal areas control of STOL aicraft. Key elements of the simulation are a computer graphics traffic display, a scheduling display and a keyboard language for issuing controller commands to simulated aircraft. Initial results and planned experiments are described.

Tobias, L.↗

Intermittent gravity: How much, how often, how long?

Continuous exposure to gravity may not be necessary to prevent the deconditioning effects of microgravity. It is not known, however, what the minimum gravity (G) exposure reguirements are, whether they vary for different physiological systems, or whether passive Gz (gravity in the head-to-toe vector) or activity in a G field is more effective in preventing deconditioning. It is also not known what the optimal characteristics of the G stimulus should be in terms of amplitude, duration, and frequency. To begin to address these questions, a 4-day -6 deg head-down bed rest (HDBR) study was conducted. Nine males (aged 30-50 yr) were subjected, over a period of seven months, to four different +1 Gz exposure protocols (periodic standing or controlled walking each for a total of 2 or 4 hr/day in individual 15-min doses), plus a control (0 Gz) of continuous HDBR. The study consisted of one ambulatory control day, 4 full days of -6 deg HDBR, and a recovery day when subjects were released at the end of HDBR after completion of tests. A battery of tests was selected and standardized in order to evaluate the known early responses to HDBR. Dependent variables of interest included orthostatic tolerance (30 min at 60 deg head-up tilt) and hemodynamics during head-up tilt, peak oxygen consumption (VO2(sub peak)) plasma volume (PV), and urinary calcium (Ca). The results were as follows: 4 hr standing completely prevented and 2 hr walking partially prevented post-HDBR orthostatic intolerance. Walking at 3 mi/hr for 4 hr/day provided no additional benefit. Intermittent walking attenuated, but did not prevent, the decrease in VO2(sub peak). Both 4 hr conditions showed less PV loss by the end of HDBR; both 2 hr conditions were without effect. Both 2 and 4 hr walking essentially prevented urinary Ca excretion and were more effective than standing. It is concluded that different physiological systems benefit differentially from passive +1 Gz or activity in +1 Gz, and the intensity of the stimulus may be an important contributing factor.

Vernikos, Joan↗

Spatially Resolved, In Situ Carbon Isotope Analysis of Archean Organic Matter

Spatiotemporal variability in the carbon isotope composition of sedimentary organic matter (OM) preserves information about the evolution of the biosphere and of the exogenic carbon cycle as a whole. Primary compositions, and imprints of the post-depositional processes that obscure them, exist at the scale of individual sedimentary grains (mm to micron). Secondary ion mass spectrometry (SIMS) (1) enables analysis at these scales and in petrographic context, (2) permits morphological and compositional characterization of the analyte and associated minerals prior to isotopic analysis, and (3) reveals patterns of variability homogenized by bulk techniques. Here we present new methods for in situ organic carbon isotope analysis with sub-permil precision and spatial resolution to 1 micron using SIMS, as well as new data acquired from a suite of Archean rocks. Three analytical protocols were developed for the CAMECA ims1280 at WiscSIMS to analyze domains of varying size and carbon concentration. Average reproducibility (at 2SD) using a 6 micron spot size with two Faraday cup detectors was 0.4 %, and 0.8 % for analyses using 1 micron and 3 micron spot sizes with a Faraday cup (for C-12) and an electron multiplier (for C-13). Eight coals, two ambers, a shungite, and a graphite were evaluated for micron-scale isotopic heterogeneity, and LCNN anthracite (delta C-13 = -23.56 +/- 0.1 %, 2SD) was chosen as the working standard. Correlation between instrumental bias and H/C was observed and calibrated for each analytical session using organic materials with H/C between 0.1 and 1.5 (atomic), allowing a correction based upon a C-13H/C-13 measurement included in every analysis. Matrix effects of variable C/SiO2 were evaluated by measuring mm to sub-micron graphite domains in quartzite from Bogala mine, Sri Lanka. Apparent instrumental bias and C-12 count rate are correlated in this case, but this may be related to a crystal orientation effect in graphite. Analyses of amorphous Archean OM suggest that instrumental bias is consistent for 12C count rates as low as 10% relative to anthracite. Samples from the ABDP-9 (n=3; Mount McRae Shale, approximately 2.5 Ga), RHDH2a (n=2; Carrawine Dolomite and Jeerinah Fm, approximately 2.6 Ga), WRL1 (n=3; Wittenoom Fm, Marra Mamba Iron Formation, and Jeerinah Fm, approximately 2.6 Ga), and SV1 (n=1; Tumbiana Fm, approximately 2.7 Ga) drill cores, each previously analyzed for bulk organic carbon isotope composition, yielded 100 new, in situ data from Neoarchean sedimentary OM. In these samples, delta C-13 varies between -53.1 and -28.3 % and offsets between in situ and bulk compositions range from -8.3 to 18.8%. In some cases, isotopic composition and mode of occurrence (e.g. morphology and mineral associations) are statistically correlated, enabling the identification of distinct reservoirs of OM. Our results support previous evidence for gradients of oxidation with depth in Neoarchean environments driven by photosynthesis and methane metabolism. The relevance of these findings to questions of bio- and syngenicity as well as the alteration history of previously reported Archean OM will be discussed.

Williford, Kenneth H.↗

Marine Hydrogen Demonstration

This report summarizes Phase 1 of a project involving the design of a Floating Hydrogen Production and Dispensing Barge destined for the Port of San Francisco (SF). The H 2 Barge is designed to produce renewable H 2 at the rate of ~ 530 kg/day, storing 512 kg of hydrogen at 517-bar, allowing fast refueling of hydrogen fuel cell vessels and land-side hydrogen delivery trailers for distribution into the nascent SF hydrogen ecosystem. The broader considerations that impacted the H2 Barge design are also described. An account is given of a new review process formulated by the United States Coast Guard (USCG) to review this first-of-its-kind maritime implementation of hydrogen technology. The immediate goals of the H 2 Barge Project are to 1) demonstrate the feasibility, viability and methods of hydrogen production, storage and fueling in a maritime context, 2) help shape (where needed) and navigate the required local, state and federal regulatory gauntlet and 3) catalyze a “green hydrogen ecosystem” (both marine and landside) with locally produced renewable hydrogen at the San Francisco waterfront. A summary is also given of the modeling and experimental activity of Phase 1 directed to the development of science-based refueling protocols for large marine Type IV 250-bar hydrogen tanks. Combined modeling and experimental studies are reported of the filling of large (28 kg) 250-bar Type IV hydrogen tanks of the type being deployed on early hydrogen ferries, such as the MV Sea Change. The primary question was to determine how such tanks can be successfully filled (state of charge greater than 97%) within 45 minutes without exceeding the 82 °C temperature limit historically set for such tanks. The studies show that a gas injector is needed avoid thermal stratification during filling which can result in potential hot spots. Pre-cooling of the hydrogen was found to be essential in most cases, as ambient conditions greatly affect the need for a pre-cooling to achieve the 45-minute fill time. Pre-cooling cannot be supplied by nearby water, such as that found in nature (bays, lakes, rivers, etc.) because pre-cooling cooling below 0 °C was found to be necessary to avoid excessive compression heating. The experimental results afforded a calibration of the engineering model (SOFIL) for these large 250-bar tanks, which now enables using SOFIL to predict volume-averaged hydrogen filling temperatures to an accuracy of +/- 2.7°C for these tanks. The model can therefore be used to evaluate potential scenarios for development of a standardized fueling methodology for ferries utilizing large Type-IV tanks of the type examined here.