Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Predetermining acceptable noise limits in EXAFS spectra in the limit of stochastic noise

EXAFS measurements are used to probe a variety of experimental systems, but excel at elucidating local structure in samples which have slight disorder or no long-range crystalline order. Of special interest to the authors is the use of EXAFS in understanding the molecular-level binding structure and characteristics of actinides on the surface of environmental minerals and model mineral analogs. In environmental systems the element of interest can be on the order of 10-7% by weight of the total sample. Obviously such samples would be impossible to measure using EXAFS techniques. It is therefore essential to increase the concentration of the element of interest while still preserving a sample's ability to represent environmental conditions. Under such low concentration limits it is expected that the collected data is countrate, or stochastically limited. This condition occurs as we approach the signal-to-noise (S/N) limit of the technique where the random noise of the measurement process dominates over possible systematic errors. When stochastic error is expected to dominate systematic error, it is possible to predict, with the use of simulations, the ability of model fits to tolerate a certain level of stochastic noise. Elsewhere in these proceedings, we discuss how to tell when systematic errors dominate in measured EXAFS spectrum. Here, we outline a technique for determining the number of EXAFS scans necessary to test the relevance of a given structural model. Appropriate stochastic noise levels are determined for each point in r-space by collecting data on a real system. These noise levels are then applied to EXAFS simulations using a test model. In this way, all significant systematic error sources are eliminated in the simulated data. The structural model is then fit to the simulated data, decreasing the noise and increasing the k-range of the fit until the veracity of the model passes an F-test. This paper outlines a method of testing model systems in EXAFS fitting before measurements are conducted to determine the quality of measured data required for fitting of a particular model system with statistical confidence. It is important to reiterate that the calculated {alpha}surface in figure 1 is only applicable to the particular model presented in this paper. Furthermore, this procedure only takes into account stochastic noise; consequentially any confidence levels calculated should be viewed as upper limits to the confidence levels in systems which also contain a significant amount of systematic noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatially extended measurements of magnetic field strength in solar plages

The study determines magnetic field strengths along one spatial dimension of a plage region from circularly polarized (Stokes V) spectra of a highly Zeeman-sensitive iron line at 6388.6/cm (1.565 micron). The measured fields are found to lie primarily in the range 1200-1700 G. The mean formal precision for a single determination is +/-65 G. More than 90 percent of the magnetic flux is kilogauss-strength fields. The field strength is coherently organized on spatial scales from 1 arcmin to the limit of angular resolution (2 arcsec). It is inferred from the amplitude of the V signal that the spatial filling factor of the strong-field elements can approach 0.5 within a 2-arcsec resolution element. Magnetic field strength and amplitude are correlated in the sense that locations with stronger mean fields have larger V amplitudes, but the relationship shows more scatter than can be explained by errors in measurement. The individual sigma-components of the V profile are broader than an average quiet-sun line profile would produce by an amount corresponding to 625 G or 4.1 km/s; Zeeman broadening due to a range of magnetic field strength within the resolution element is proposed as the likely explanation.

Rabin, Douglas↗

Combined high-pressure neutron and X-ray diffraction study of H-D substitution effects on brucite

The high-pressure behavior of the mineral brucite, Mg(OH)2, is of great geochemical and geophysical interest, because brucite-type minerals serve as a simple analog for more complex, hydrogen-bearing oxide and silicate minerals in the deep-earth. A combined neutron and synchrotron x-ray powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 and 20 GPa, using a Paris-Edinburgh (neutron diffraction) and a diamond anvil cell (synchrotron x-ray radiation), respectively. The two materials were synthesized by the same method and companion diffraction measurements of the two materials were conducted under the same conditions. Our experimental results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decrease only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg (OD)2 is shorter and may exhibit greater compressibility with pressure than that of Mg (OH)2. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of hydrogenated brucite. Fitting to a third-order Birch-Murnaghan equation shows that values of the bulk modulus for hydrogenated and deuterated brucite are indistinguishable from each other within the experimental errors. The measured effect of H-D substitution on the unit-cell volume demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

Brucite↗

A three dimensional probe positioner

In order to sort out the physics that is important in many plasma experiments, data in three dimensions (3D) are becoming necessary. Access to the usual cylindrical vacuum vessel is typically restricted to radially or axially insertable probes that can pivot. The space that can be explored usually has significant restrictions either because probe travel must be along a travel path, or a 'wobbly' probe positioner requires one to map between a moveable coordinate system and a preferred laboratory coordinate system. This could for example introduce errors in measurements of vector quantities such as magnetic field or flow. We describe the design and implementation of a 3D probe positioner that slides in two dimensions on a double O-ring seal and radially inserts along the third dimension. The net result is that a 3D space can be explored in a laboratory Cartesian reference frame.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined high-pressure neutron and X-ray diffraction study of H-D substitution effects on brucite

The high-pressure behavior of the mineral brucite, Mg(OH){sub 2}, is of great geochemical and geophysical interest, because brucite-type minerals serve as a simple analog for more complex, hydrogen-bearing oxide and silicate minerals in the deep-earth. A combined neutron and synchrotron x-ray powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 and 20 GPa, using a Paris-Edinburgh (neutron diffraction) and a diamond anvil cell (synchrotron x-ray radiation), respectively. The two materials were synthesized by the same method and companion diffraction measurements of the two materials were conducted under the same conditions. Our experimental results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decrease only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg (OD){sub 2} is shorter and may exhibit greater compressibility with pressure than that of Mg (OH){sub 2}. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of hydrogenated brucite. Fitting to a third-order Birch-Murnaghan equation shows that values of the bulk modulus for hydrogenated and deuterated brucite are indistinguishable from each other within the experimental errors. The measured effect of H-D substitution on the unit-cell volume demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

36 MATERIALS SCIENCE↗

Accuracy of the Cloud Integrating Nephelometer

Potential error sources for measurements with the Cloud Integrating Nephelometer (CIN) are discussed and analyzed, including systematic errors of the measurement approach, flow and particle-trajectory deviations at flight velocity, ice-crystal breakup on probe surfaces, and errors in calibration and developing scaling constants. It is concluded that errors are minimal, and that the accuracy of the CIN should be close to the systematic behavior of the CIN derived in Gerber et al (2000). Absolute calibration of the CIN with a transmissometer operating co-located in a mountain-top cloud shows that the earlier scaling constant for the optical extinction coefficient obtained by other means is within 5% of the absolute calibration value, and that the CIN measurements on the Citation aircraft flights during the CRYSTAL-FACE study are accurate.

Gerber, Hermann E.↗

Metrology System for a Large, Somewhat Flexible Telescope

A proposed metrology system would be incorporated into a proposed telescope that would include focusing optics on a rigid bench connected via a deployable mast to another rigid bench holding a focal-plane array of photon counting photodetectors. Deformations of the deployable mast would give rise to optical misalignments that would alter the directions (and, hence, locations) of incidence of photons on the focal plane. The metrology system would measure the relative displacement of the focusing- optics bench and the focal-plane array bench. The measurement data would be used in post-processing of the digitized photodetector outputs to compensate for the mast-deformation-induced changes in the locations of incidence of photons on the focal plane, thereby making it possible to determine the original directions of incidence of photons with greater accuracy. The proposed metrology system is designed specifically for the Nuclear Spectroscopic Telescope Array (NuSTAR) a proposed spaceborne x-ray telescope. The basic principles of design and operation are also applicable to other large, somewhat flexible telescopes, both terrestrial and spaceborne. In the NuSTAR, the structural member connecting the optical bench and the photodetector array would be a 10-m-long deployable mast, and there is a requirement to keep errors in measured directions of incidence of photons below 10 arc seconds (3 sigma). The proposed system would include three diode lasers that would be mounted on the focusing-optics bench. For clarity, only one laser is shown in the figure, which is a greatly simplified schematic diagram of the system. Each laser would be aimed at a position-sensitive photodiode that would be mounted on the detector bench alongside the aforementioned telescope photodetector array. The diode lasers would operate at a wavelength of 830 nm, each at a power of 200 mW. Each laser beam would be focused to a spot of .1-mm diameter on the corresponding position-sensitive photodiode. To reduce the effect of sunlight on the measurements, a one-stage light baffle and an 830-nm transmission filter of 10-nm bandwidth would be placed in front of the position- sensitive photodiode. For each metrology reading, the output of the position-sensitive detector would be sampled and digitized twice: once with the lasers turned on, then once with the lasers turned off. The data from these two sets of samples would be subtracted from each other to further reduce the effects of sun glints or other background light sources.

Liebe, Carl Christian↗

Planck 2013 results. XVI. Cosmological parameters

This paper presents the first cosmological results based on Planck measurements of the cosmic microwave background (CMB) temperature and lensing-potential power spectra. We find that the Planck spectra at high multipoles (&ell; ≳ 40) are extremely well described by the standard spatially-flat six-parameter ΛCDM cosmology with a power-law spectrum of adiabatic scalar perturbations. Within the context of this cosmology, the Planck data determine the cosmological parameters to high precision: the angular size of the sound horizon at recombination, the physical densities of baryons and cold dark matter, and the scalar spectral index are estimated to be θ &lowast; = (1.04147 ± 0.00062) × 10 -2 , Ω b h 2 = 0.02205 ± 0.00028, Ω c h 2 = 0.1199 ± 0.0027, and n s = 0.9603 ± 0.0073, respectively (note that in this abstract we quote 68% errors on measured parameters and 95% upper limits on other parameters). For this cosmology, we find a low value of the Hubble constant, H 0 = (67.3 ± 1.2) km s -1 Mpc -1 , and a high value of the matter density parameter, Ω m = 0.315 ± 0.017. These values are in tension with recent direct measurements of H 0 and the magnitude-redshift relation for Type Ia supernovae, but are in excellent agreement with geometrical constraints from baryon acoustic oscillation (BAO) surveys. Including curvature, we find that the Universe is consistent with spatial flatness to percent level precision using Planck CMB data alone. We use high-resolution CMB data together with Planck to provide greater control on extragalactic foreground components in an investigation of extensions to the six-parameter ΛCDM model. We present selected results from a large grid of cosmological models, using a range of additional astrophysical data sets in addition to Planck and high-resolution CMB data. None of these models are favoured over the standard six-parameter ΛCDM cosmology. The deviation of the scalar spectral index from unity is insensitive to the addition of tensor modes and to changes in the matter content of the Universe. We find an upper limit of r 0.002 < 0.11 on the tensor-to-scalar ratio. There is no evidence for additional neutrino-like relativistic particles beyond the three families of neutrinos in the standard model. Using BAO and CMB data, we find N eff = 3.30 ± 0.27 for the effective number of relativistic degrees of freedom, and an upper limit of 0.23 eV for the sum of neutrino masses. Our results are in excellent agreement with big bang nucleosynthesis and the standard value of N eff = 3.046. We find no evidence for dynamical dark energy; using BAO and CMB data, the dark energy equation of state parameter is constrained to be w = -1.13 -0.10 +0.13 . We also use the Planck data to set limits on a possible variation of the fine-structure constant, dark matter annihilation and primordial magnetic fields. Despite the success of the six-parameter ΛCDM model in describing the Planck data at high multipoles, we note that this cosmology does not provide a good fit to the temperature power spectrum at low multipoles. The unusual shape of the spectrum in the multipole range 20 ≲ &ell; ≲ 40 was seen previously in the WMAP data and is a real feature of the primordial CMB anisotropies. The poor fit to the spectrum at low multipoles is not of decisive significance, but is an "anomaly" in an otherwise self-consistent analysis of the Planck temperature data.

79 ASTRONOMY AND ASTROPHYSICS↗

Image Correlation Pattern Optimization for Micro-Scale In-Situ Strain Measurements

The accuracy and precision of digital image correlation (DIC) is a function of three primary ingredients: image acquisition, image analysis, and the subject of the image. Development of the first two (i.e. image acquisition techniques and image correlation algorithms) has led to widespread use of DIC; however, fewer developments have been focused on the third ingredient. Typically, subjects of DIC images are mechanical specimens with either a natural surface pattern or a pattern applied to the surface. Research in the area of DIC patterns has primarily been aimed at identifying which surface patterns are best suited for DIC, by comparing patterns to each other. Because the easiest and most widespread methods of applying patterns have a high degree of randomness associated with them (e.g., airbrush, spray paint, particle decoration, etc.), less effort has been spent on exact construction of ideal patterns. With the development of patterning techniques such as microstamping and lithography, patterns can be applied to a specimen pixel by pixel from a patterned image. In these cases, especially because the patterns are reused many times, an optimal pattern is sought such that error introduced into DIC from the pattern is minimized. DIC consists of tracking the motion of an array of nodes from a reference image to a deformed image. Every pixel in the images has an associated intensity (grayscale) value, with discretization depending on the bit depth of the image. Because individual pixel matching by intensity value yields a non-unique scale-dependent problem, subsets around each node are used for identification. A correlation criteria is used to find the best match of a particular subset of a reference image within a deformed image. The reader is referred to references for enumerations of typical correlation criteria. As illustrated by Schreier and Sutton and Lu and Cary systematic errors can be introduced by representing the underlying deformation with under-matched shape functions. An important implication, as discussed by Sutton et al., is that in the presence of highly localized deformations (e.g., crack fronts), error can be reduced by minimizing the subset size. In other words, smaller subsets allow the more accurate resolution of localized deformations. Contrarily, the choice of optimal subset size has been widely studied and a general consensus is that larger subsets with more information content are less prone to random error. Thus, an optimal subset size balances the systematic error from under matched deformations with random error from measurement noise. The alternative approach pursued in the current work is to choose a small subset size and optimize the information content within (i.e., optimizing an applied DIC pattern), rather than finding an optimal subset size. In the literature, many pattern quality metrics have been proposed, e.g., sum of square intensity gradient (SSSIG), mean subset fluctuation, gray level co-occurrence, autocorrelation-based metrics, and speckle-based metrics. The majority of these metrics were developed to quantify the quality of common pseudo-random patterns after they have been applied, and were not created with the intent of pattern generation. As such, it is found that none of the metrics examined in this study are fit to be the objective function of a pattern generation optimization. In some cases, such as with speckle-based metrics, application to pixel by pixel patterns is ill-conditioned and requires somewhat arbitrary extensions. In other cases, such as with the SSSIG, it is shown that trivial solutions exist for the optimum of the metric which are ill-suited for DIC (such as a checkerboard pattern). In the current work, a multi-metric optimization method is proposed whereby quality is viewed as a combination of individual quality metrics. Specifically, SSSIG and two auto-correlation metrics are used which have generally competitive objectives. Thus, each metric could be viewed as a constraint imposed upon the others, thereby precluding the achievement of their trivial solutions. In this way, optimization produces a pattern which balances the benefits of multiple quality metrics. The resulting pattern, along with randomly generated patterns, is subjected to numerical deformations and analyzed with DIC software. The optimal pattern is shown to outperform randomly generated patterns.

Bomarito, G. F.↗

High-Pressure Neutron Diffraction Study on H-D Isotope Effects in Brucite

A neutron powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 GPa, using a Paris-Edinburgh high-pressure cell at the WAND instrument of ORNL High Flux Isotope Reactor. The two materials were synthesized by the same method and companion measurements of neutron diffraction were conducted under the same conditions. Our refinement results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decreases only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg(OD)2 is shorter and decreases more rapidly than that of Mg(OH)2 with increasing pressure. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of normal brucite, which were fitted to third-order Birch-Murnaghan equation: K0=41.46 0.52 and 39.04 0.30 GPa for Mg(OH)2 and Mg(OD)2, respectively with a fixed K0 value of 10. Our results suggest that H-D substitution of brucite and other hydrous minerals with H-bonding likely influences their structural and dynamic properties under pressure, including the position of hydrogen atoms. The measured effect of H-D substitution on the unit-cell volume also demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

08 HYDROGEN↗

Scalable quantum processor noise characterization

Measurement fidelity matrices (MFMs) (also called error kernels) are a natural way to characterize state preparation and measurement errors in near-term quantum hardware. They can be employed in post processing to mitigate errors and substantially increase the effective accuracy of quantum hardware. However, the feasibility of using MFMs is currently limited as the experimental cost of determining the MFM for a device grows exponentially with the number of qubits. In this work we present a scalable way to construct approximate MFMs for many-qubit devices based on cumulant expansions. Our method can also be used to characterize various types of correlation error.

Hamilton, Kathleen↗

Two-dimensional stitching interferometry for self-calibration of high-order additive systematic errors

Stitching interferometry is performed by collecting interferometric data from overlapped sub-apertures and stitching these data together to provide a full surface map. The propagation of the systematic error in the measured subset data is one of the main error sources in stitching interferometry for accurate reconstruction of the surface topography. In this work, we propose, using the redundancy of the captured subset data, two types of two-dimensional (2D) self-calibration stitching algorithms to overcome this issue by in situ estimating the repeatable high-order additive systematic errors, especially for the application of measuring X-ray mirrors. The first algorithm, called CS short for “Calibrate, and then Stitch”, calibrates the high-order terms of the reference by minimizing the de-tilted discrepancies of the overlapped subsets and then stitches the reference-subtracted subsets. The second algorithm, called SC short for “Stitch, and then Calibrate”, stitches a temporarily result and then calibrates the reference from the de-tilted discrepancies of the measured subsets and the temporarily stitched result. In the implementation of 2D scans in $x$- and y -directions, step randomization is introduced to generate nonuniformly spaced subsets which can diminish the periodic stitching errors commonly observed in evenly spaced subsets. The regularization on low-order terms enables a highly flexible option to add the curvature and twist acquired by another system. Both numerical simulations and experiments are carried out to verify the proposed method. All the results indicate that 2D high-order repeatable additive systematic errors can be retrieved from the 2D redundant overlapped data in stitching interferometry.

42 ENGINEERING↗

Absolute energy calibration for relativistic electron beams with pointing instability from a laser-plasma accelerator

The pointing instability of energetic electron beams generated from a laser-driven accelerator can cause a serious error in measuring the electron spectrum with a magnetic spectrometer. In order to determine a correct electron spectrum, the pointing angle of an electron beam incident on the spectrometer should be exactly defined. Here, we present a method for absolutely calibrating the electron spectrum by monitoring the pointing angle using a scintillating screen installed in front of a permanent dipole magnet. The ambiguous electron energy due to the pointing instability is corrected by the numerical and analytical calculations based on the relativistic equation of electron motion. It is also possible to estimate the energy spread of the electron beam and determine the energy resolution of the spectrometer using the beam divergence angle that is simultaneously measured on the screen. The calibration method with direct measurement of the spatial profile of an incident electron beam has a simple experimental layout and presents the full range of spatial and spectral information of the electron beams with energies of multi-hundred MeV level, despite the limited energy resolution of the simple electron spectrometer.

43 PARTICLE ACCELERATORS↗

Ab initio wavenumber accurate spectroscopy : {sup 1}CH{sub 2} and HCN vibrational levels on automatically generated IMLS potential energy surfaces.

We report here calculated J = 0 vibrational frequencies for {sup 1}CH{sub 2} and HCN with root-mean-square error relative to available measurements of 2.0 cm{sup -1} and 3.2 cm{sup -1}, respectively. These results are obtained with DVR calculations with a dense grid on ab initio potential energy surfaces (PESs). The ab initio electronic structure calculations employed are Davidson-corrected MRCI calculations with double-, triple-, and quadruple-{zeta} basis sets extrapolated to the complete basis set (CBS) limit. In the {sup 1}CH{sub 2} case, Full CI tests of the Davidson correction at small basis set levels lead to a scaling of the correction with the bend angle that can be profitably applied at the CBS limit. Core-valence corrections are added derived from CCSD(T) calculations with and without frozen cores. Relativistic and non-Born-Oppenheimer corrections are available for HCN and were applied. CBS limit CCSD(T) and CASPT2 calculations with the same basis sets were also tried for HCN. The CCSD(T) results are noticeably less accurate than the MRCI results while the CASPT2 results are much poorer. The PESs were generated automatically using the local interpolative moving least-squares method (L-IMLS). A general triatomic code is described where the L-IMLS method is interfaced with several common electronic structure packages. All PESs were computed with this code running in parallel on eight processors. The L-IMLS method provides global and local fitting error measures important in automatically growing the PES from initial ab initio seed points. The reliability of this approach was tested for {sup 1}CH{sub 2} by comparing DVR-calculated vibrational levels on an L-IMLS ab initio surface with levels generated by an explicit ab initio calculation at each DVR grid point. For all levels ({approx}200) below 20000 cm{sup -1}, the mean unsigned difference between the levels of these two calculations was 0.1 cm{sup -1}, consistent with the L-IMLS estimated mean unsigned fitting error of 0.3 cm{sup -1}. All L-IMLS PESs used in this work have comparable mean unsigned fitting errors, implying that fitting errors have a negligible role in the final errors of the computed vibrational levels with experiment. Less than 500 ab initio calculations of the energy and gradients are required to achieve this level of accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Home Mobility Frequency and Stability in Older Adults Living Alone With or Without MCI: Introduction of New Metrics

Background: Older adults spend a considerable amount of time inside their residences; however, most research investigates out-of-home mobility and its health correlates. We measured indoor mobility using room-to-room transitions, tested their psychometric properties, and correlated indoor mobility with cognitive and functional status. Materials and Methods: Community-dwelling older adults living alone ( n = 139; age = 78.1 ± 8.6 years) from the Oregon Center for Aging & Technology (ORCATECH) and Minority Aging Research Study (MARS) were included in the study. Two indoor mobility features were developed using non-parametric parameters (frequency; stability): Indoor mobility frequency (room-to-room transitions/day) was detected using passive infrared (PIR) motion sensors fixed on the walls in four geographic locations (bathroom; bedroom; kitchen; living room) and using door contact sensors attached to the egress door in the entrance. Indoor mobility stability was estimated by variances of number of room-to-room transitions over a week. Test-retest reliability (Intra-class coefficient, ICC) and the minimal clinically important difference (MCID) defined as the standard error of measurement (SEM) were generated. Generalized estimating equations models related mobility features with mild cognitive impairment (MCI) and functional status (gait speed). Results: An average of 206 days (±127) of sensor data were analyzed per individual. Indoor mobility frequency and stability showed good to excellent test-retest reliability (ICCs = 0.91[0.88–0.94]; 0.59[0.48–0.70]). The MCIDs of mobility frequency and mobility stability were 18 and 0.09, respectively. On average, a higher indoor mobility frequency was associated with faster gait speed (β = 0.53, p = 0.04), suggesting an increase of 5.3 room-to-room transitions per day was associated with an increase of 10 cm/s gait speed. A decrease in mobility stability was associated with MCI (β = −0.04, p = 0.03). Discussion: Mobility frequency and stability in the home are clinically meaningful and reliable features. Pervasive-sensing systems deployed in homes can objectively reveal cognitive and functional status in older adults who live alone.

Wu, Chao-Yi↗

Overview of the TOPEX/Poseidon Platform Harvest Verification Experiment

An overview is given of the in situ measurement system installed on Texaco's Platform Harvest for verification of the sea level measurement from the TOPEX/Poseidon satellite. The prelaunch error budget suggested that the total root mean square (RMS) error due to measurements made at this verification site would be less than 4 cm. The actual error budget for the verification site is within these original specifications. However, evaluation of the sea level data from three measurement systems at the platform has resulted in unexpectedly large differences between the systems. Comparison of the sea level measurements from the different tide gauge systems has led to a better understanding of the problems of measuring sea level in relatively deep ocean. As of May 1994, the Platform Harvest verification site has successfully supported 60 TOPEX/Poseidon overflights.

Morris, Charles S.↗

Estimation of errors in the TOMS total ozone measurement during the Antarctica ozone campaign of August/September 1987

The Total Ozone Mapping Spectrometer (TOMS) instrument on the Nimbus-7 satellite provides the primary source of total ozone data for the study of total ozone in the polar regions of the earth. There are two types of instrument related errors: a slowly developing drift in the instrument calibration since the launch of the instrument in October 1978 and an increase in the measurement noise beginning April, 1984. It is estimated that by October 1987, the accumulated error in the TOMS total ozone measurement due to instrument drift is about 6 m-atm-cm. The sign of the error is such that the TOMS is slightly overpredicting the long-term decrease of the Antarctica ozone. The increase in the measurement noise is more difficult to quantify, affecting some measurements by as much as 10 D.U. and others not at all. A detailed analysis of this error and its potential impact on the studies of total ozone from TOMS will be provided. There are three categories of algorithmic errors: (1) error due the unusual shape of the ozone profile in the ozone hole; (2) error caused by very low atmospheric temperatures in the ozone hole affecting the ozone absorption cross-sections at the TOMS wavelengths; and (3) errors resulting from occasionally thick stratospheric clouds that sometimes reach to 20 km in the ozone hole.

Bhartia, P. K.↗

Chirped-probe-pulse femtosecond CARS thermometry in turbulent spray flames

This paper presents temperature measurements in turbulent dilute and dense spray flames using single-laser-shot chirped-probe-pulse femtosecond coherent anti-Stokes Raman spectroscopy (CPP-fs-CARS). This ultrafast technique, with a repetition rate of 5 kHz, is applied to the piloted Sydney Needle Spray Burner (SYNSBURN TM ). The burner system features air-blast atomization of liquid injected from a needle that can be translated within a co-flowing air stream. The pilot-stabilized spray flames can range between the two extremes of dense and dilute by physically translating the needle tip relative to the burner's exit plane. The CPP-fs-CARS set-up has achieved integration times of 3 picoseconds (ps) as well as spatial resolution of approximately 800 µm along beam propagation and 60 µm in the transverse dimension. Brief details of the technique, calibration, correction of interferences, and spectral fitting processes are presented along with estimates of the associated error. The measurements are compared against well-established, line Raman–Rayleigh data for temperature collected in a turbulent CH 4 /air jet diffusion flame, which is largely non-sooting. At peak gaseous flame temperatures of up to 2512 K, the relative accuracy and precision were 2.8% and ±3.4%, respectively. Measurements in turbulent spray flames are shown after applying the relevant corrections based on non-resonant background (NRB) behavior and camera saturation effects on the shape of the CARS signal spectrum. Preliminary mapping of the temperature fields demonstrates the wealth of information available in this dataset which will provide insights into the spatio-temporal structure of spray flames once relevant statistical analysis is applied.

42 ENGINEERING↗