Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Phase Portrait of a Scattered Charged-Particle Bunch

The distribution function of a moving charge experiencing multiple Coulomb scattering has been used to derive relationships for the scattered beam parameters through the parameters of a beam incident on a target. The notion of a beam consistent with a target has been introduced, and a formula has been derived that relates the emittances of the incident and scattered beams.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of $\pi ^\pm $, $K^\pm $, p and $\bar{p}$ spectra in $^{40}\hbox {Ar+}^{45}\hbox {Sc}$ collisions at 13A to 150A $\text{ Ge }\hspace{-1.00006pt}\text{ V }\!/\!c$

The NA61/SHINE experiment at the CERN Super Proton Synchrotron studies the onset of deconfinement in strongly interacting matter through a beam energy scan of particle production in collisions of nuclei of varied sizes. This paper presents results on inclusive double-differential spectra, transverse momentum and rapidity distributions and mean multiplicities of $\pi ^\pm $, $K^\pm $, p and $\bar{p}$ produced in $^{40}\hbox {Ar+}^{45}\hbox {Sc}$ collisions at beam momenta of 13A, 19A, 30A, 40A, 75A and 150A $\text{ Ge }\hspace{-1.00006pt}\text{ V }\!/\!c$. The analysis uses the 10% most central collisions, where the observed forward energy defines centrality. The energy dependence of the $K^\pm $/$\pi ^\pm $ ratios as well as of inverse slope parameters of the $K^\pm $ transverse mass distributions are placed in between those found in inelastic $p+p$ and central Pb + Pb collisions. The results obtained here establish a system-size dependence of hadron production properties that so far cannot be explained either within statistical or dynamical models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of higher-order cumulants of multiplicity and net-electric charge distributions in inelastic proton-proton interactions by NA61/SHINE

This paper presents the energy dependence of multiplicity and net-electric charge fluctuations in p+p interactions at beam momenta 20, 31, 40, 80, and 158 \(\text{ Ge }\hspace{-1.00006pt}\text{ V }\!/\!c\). Results are corrected for the experimental biases and quantified with the use of cumulants and factorial cumulants. Cumulant ratios are an essential tool in the search for the critical point of strongly interacting matter in heavy ion collisions. Measurements performed in p+p interactions provide a vital baseline estimation in these studies. The measured signals are compared with the string hadronic models Epos1.99 and FTFP-BERT.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation of Intense Beams and Targets for Heavy-Ion-Fusion Science (HEDLP / Inertial Fusion Energy)

Our principal goals, and activities in support of those goals, over the next five years are as follows: (1) Optimize the properties of the NDCX-II beam for each class of target experiments; achieve quantitative agreement with measurements; develop improved machine configurations and operating points. To accomplish these goals, we plan to use Warp to simulate NDCX-II from source to target, in full kinetic detail, including first-principles modeling of beam neutralization by plasma. The output from an ensemble of Warp runs (representing shot-to-shot variations) will be used as input to target simulations using ALE-AMR on NERSC, and other codes. (2) Develop enhanced versions of NDCX-II (the machine is designed to be extensible and reconfigurable), and carry out studies to define a next-step ion beam facility. To accomplish these goals, much of the work will involve iterative optimization employing Warp runs that assume ideal beam neutralization downstream of the accelerator. (3) Carry out detailed target simulations in the Warm Dense Matter regime using the ALE-AMR code, including surface tension effects, liquid-vapor coexistence, and accurate models of both the driving beam and the target geometry. For this we will need to make multiple runs (to capture shot-to-shot variations), and to both develop and employ synthetic diagnostics (to enable comparison with experiments). The new science that will be revealed is the physics of the transition from the liquid to vapor state of a volumetrically superheated material, wherein droplets are formed, and wherein phase transitions, surface tension and hydrodynamics all play significant roles in the dynamics. These simulations will enable calculations of equation of state and other material properties, and will also be of interest for their illumination of the science of droplet formation.

43 PARTICLE ACCELERATORS↗

Exploring the Nature of Neutrinos with the Deep Underground Neutrino Experiment (DUNE)

The Deep Underground Neutrino Experiment (DUNE) is a next-generation experimental program designed to study the behaviour of neutrino oscillation. DUNE will utilize a neutrino beam originating at Fermilab, near Chicago, and will leverage a detector at Fermilab (Near Detector) and a detector 1300 km away in South Dakota (Far Detector), south of Saskatchewan. In the first phase of DUNE, its Far Detector will comprise of two 10,000 ton (fiducial) liquid argon (LAr) time-projection chamber (TPC) modules – powerful tracking calorimeter detectors – placed nearly a mile underground. With this large, sensitive, underground detector, DUNE aims to collect a high statistics and pure sample of neutrinos at the Far Detector. This setup also offers the potential to study non-beam physical processes via e.g. neutrinos produced in the atmosphere, supernova neutrino bursts, and/or solar neutrinos, etc. A second phase will aim to add more detector mass and expand the program. The Near Detector will consist of a LAr TPC module as well: critical to constraining systematic uncertainties in the oscillation analysis. However, this LAr TPC will have a novel design using a pixel-based readout instead of the traditional wire-based readout. This and the segmentation of the LAr TPC into multiple units are crucial in mitigating the high multiplicity of neutrino interactions expected in any readout window given its proximity to the beam. The Near Detector will feature additional components and capability beyond the LAr TPC, allowing one to deeply characterize the neutrino flux. Due to the complexity of this experimental program, several smaller-scale prototype detectors have been operating to test, validate, and improve both the technical designs and software for processing and analyzing events. By operating in charged particle test beams or neutrino beams, several of the prototypes are also capable of producing valuable results. Canadian institutions are involved in the realization of the DUNE through efforts with both the Near and Far Detectors and prototypes. DUNE is anticipated to begin operating near the end of this decade/the beginning of the next. This talk will focus on the overall DUNE program, for example its ultimate plans, status, and the efforts with prototypes.

Howard, Bruce [York U., Canada; Fermilab]↗

The uniform transparent gravitational lens.

An elementary discussion is given of the gravitational deflection of light due to radially and cylindrically symmetric masses. The effect of the deflection on apparent luminosity of distant sources is also considered. All results are limited to weak, static, asymptotically flat gravitational fields. Emphasis here is on observations of sources aligned behind the disc of the deflecting mass so that the possible transparency of this mass is decisive in image formation. Detailed calculations are made for the simple case of the uniformly dense transparent sphere and comparisons are made with the opaque mass sphere. If they have the same mass and radius, the maximum light deflection produced by these lenses is nearly equal. However, their effects on the area of narrow light beams may be quite different. The uniform transparent sphere does not produce multiple images of one source and, to first order, introduces no image distortion.

Clark, E. E.↗

Numerical methods for stiff systems of two-point boundary value problems

Numerical procedures are developed for constructing asymptotic solutions of certain nonlinear singularly perturbed vector two-point boundary value problems having boundary layers at one or both endpoints. The asymptotic approximations are generated numerically and can either be used as is or to furnish a general purpose two-point boundary value code with an initial approximation and the nonuniform computational mesh needed for such problems. The procedures are applied to a model problem that has multiple solutions and to problems describing the deformation of thin nonlinear elastic beam that is resting on an elastic foundation.

Flaherty, J. E.↗

A Transient Response Method for Linear Coupled Substructures

A method is presented for determining the transient response of a discrete coordinate model of a linear structural system composed of substructures. The method is applicable to systems consisting of any number of substructures, both determinate and indeterminate interface boundaries, and any topological arrangement of the substructures. The method is simple to implement from a computational point of view because the equations of motion of each of the substructures are solved independently, and the interface boundary compatibility conditions are enforced at each integration time step by a matrix multiplication. The method is demonstrated for a structural system consisting of two beam segments and acted upon by a time dependent force. The numerical results from the demonstration problem validates the accuracy of the method. The application of this method to structural systems with changing interface boundary conditions between substructures is discussed.

Admire, J. R.↗

Precise tracking of the Magellan and Pioneer Venus orbiters by same-beam interferometry

Results of a demonstration of same-beam interferometry, the simultaneous tracking of two spacecraft in orbit about a distant planet by widely separated earth-based radio antennas, are presented with regard to the Magellan and Pioneer 12 orbiters at Venus. Signals from both spacecraft fall within the same beamwidth of the tracking antennas. The plane-of-sky position difference between spacecraft is precisely determined by double-differenced phase measurements. This data type complements line-of-sight Doppler and improves orbital accuracy by up to an order of magnitude. The predicted error is dominated by solar plasma fluctuations, and is 15.1 psec for a 5-min integration. The rms of the residuals is less than this by about 25 percent. The shape of the spectrum computed from residuals is consistent with that derived from a model of solar plasma fluctuations. Same-beam interferometry is expected to enhance tracking accuracy and efficiency for proposed multiple missions to Mars.

Border, James S.↗

Automated Track Recognition and Event Reconstruction in Nuclear Emulsion

The major advantages of nuclear emulsion for detecting charged particles are its submicron position resolution and sensitivity to minimum ionizing particles. These must be balanced, however, against the difficult manual microscope measurement by skilled observers required for the analysis. We have developed an automated system to acquire and analyze the microscope images from emulsion chambers. Each emulsion plate is analyzed independently, allowing coincidence techniques to be used in order to reject back- ground and estimate error rates. The system has been used to analyze a sample of high-multiplicity Pb-Pb interactions (charged particle multiplicities approx. 1100) produced by the 158 GeV/c per nucleon Pb-208 beam at CERN. Automatically reconstructed track lists agree with our best manual measurements to 3%. We describe the image analysis and track reconstruction techniques, and discuss the measurement and reconstruction uncertainties.

Deines-Jones, P.↗

Multiparallel Three-Dimensional Optical Microscopy

Multiparallel three-dimensional optical microscopy is a method of forming an approximate three-dimensional image of a microscope sample as a collection of images from different depths through the sample. The imaging apparatus includes a single microscope plus an assembly of beam splitters and mirrors that divide the output of the microscope into multiple channels. An imaging array of photodetectors in each channel is located at a different distance along the optical path from the microscope, corresponding to a focal plane at a different depth within the sample. The optical path leading to each photodetector array also includes lenses to compensate for the variation of magnification with distance so that the images ultimately formed on all the photodetector arrays are of the same magnification. The use of optical components common to multiple channels in a simple geometry makes it possible to obtain high light-transmission efficiency with an optically and mechanically simple assembly. In addition, because images can be read out simultaneously from all the photodetector arrays, the apparatus can support three-dimensional imaging at a high scanning rate.

Nguyen, Lam K.↗

Self-Calibration of BICEP1 Three-Year Data and Constraints on Astrophysical Polarization Rotation

Cosmic microwave background (CMB) polarimeters aspire to measure the faint B-mode signature predicted to arise from inflationary gravitational waves. They also have the potential to constrain cosmic birefringence, rotation of the polarization of the CMB arising from parity-violating physics, which would produce nonzero expectation values for the CMB's temperature to B-mode correlation (TB) and E-mode to B-mode correlation (EB) spectra. However, instrumental systematic effects can also cause these TB and EB correlations to be nonzero. In particular, an overall miscalibration of the polarization orientation of the detectors produces TB and EB spectra which are degenerate with isotropic cosmological birefringence, while also introducing a small but predictable bias on the BB spectrum. We find that BICEP1 three-year spectra, which use our standard calibration of detector polarization angles from a dielectric sheet, are consistent with a polarization rotation of alpha = −2.77deg +/- 0.86deg (statistical) +/- 1.3deg (systematic). We have revised the estimate of systematic error on the polarization rotation angle from the two-year analysis by comparing multiple calibration methods. We also account for the (negligible) impact of measured beam systematic effects. We investigate the polarization rotation for the BICEP1 100 GHz and 150 GHz bands separately to investigate theoretical models that produce frequency-dependent cosmic birefringence. We find no evidence in the data supporting either of these models or Faraday rotation of the CMB polarization by the Milky Way galaxy's magnetic field. If we assume that there is no cosmic birefringence, we can use the TB and EB spectra to calibrate detector polarization orientations, thus reducing bias of the cosmological B-mode spectrum from leaked E-modes due to possible polarization orientation miscalibration. After applying this "self-calibration" process, we find that the upper limit on the tensor-to-scalar ratio decreases slightly, from r < 0.70 to r < 0.65 at 95% confidence.

three-year↗

Separated-orbit bisected energy-recovered linear accelerator

A separated-orbit bisected energy-recovered linear accelerator apparatus and method. The accelerator includes a first linac, a second linac, and a plurality of arcs of differing path lengths, including a plurality of up arcs, a plurality of downgoing arcs, and a full energy arc providing a path independent of the up arcs and downgoing arcs. The up arcs have a path length that is substantially a multiple of the RF wavelength and the full energy arc includes a path length that is substantially an odd half-integer multiple of the RF wavelength. Operation of the accelerator includes accelerating the beam utilizing the linacs and up arcs until the beam is at full energy, at full energy executing a full recirculation to the second linac using a path length that is substantially an odd half-integer of the RF wavelength, and then decelerating the beam using the linacs and downgoing arcs.

43 PARTICLE ACCELERATORS↗

Distributed coupling high efficiency linear accelerator

A microwave circuit for a linear accelerator includes multiple monolithic metallic cell plates stacked upon each other so that the beam axis passes vertically through a central acceleration cavity of each plate. Each plate has a directional coupler with coupling arms. A first coupling slot couples the directional coupler to an adjacent directional coupler of an adjacent cell plate, and a second coupling slot couples the directional coupler to the central acceleration cavity. Each directional coupler also has an iris protrusion spaced from corners joining the arms, a convex rounded corner at a first corner joining the arms, and a corner protrusion at a second corner joining the arms.

42 ENGINEERING↗

Unresolved puzzles in the x-ray emission produced by charge exchange measured on electron beam ion traps

Charge exchange recombination, the transfer of one or more electrons from an atomic or molecular system to a positive ion, is a common phenomenon affecting laboratory and astrophysical plasmas. Controlled studies of this process in electron beam ion traps during the past one and a half decades have produced multiple observations that are difficult to explain with available spectral models. Some of the most recent observations are so puzzling that they bring in doubt the existence of a coherent predictive capability for line formation by charge exchange, making investigations of charge exchange a fertile ground for continued measurements and theoretical development.

74 ATOMIC AND MOLECULAR PHYSICS↗

Commissioning and dosimetric characteristics of TrueBeam system: Composite data of three TrueBeam machines

Purpose: A TrueBeam linear accelerator (TB-LINAC) is designed to deliver traditionally flattened and flattening-filter-free (FFF) beams. Although it has been widely adopted in many clinics for patient treatment, limited information is available related to commissioning of this type of machine. In this work, commissioning data of three units were measured, and multiunit comparison was presented to provide valuable insights and reliable evaluations on the characteristics of the new treatment system. Methods: The TB-LINAC is equipped with newly designed waveguide, carousel assembly, monitoring control, and integrated imaging systems. Each machine in this study has 4, 6, 8, 10, 15 MV flattened photon beams, and 6 MV and 10 MV FFF photon beams as well as 6, 9, 12, 16, 20, and 22 MeV electron beams. Dosimetric characteristics of the three new TB-LINAC treatment units are systematically measured for commissioning. High-resolution diode detectors and ion chambers were used to measure dosimetric data for a range of field sizes from 10 Multiplication-Sign 10 to 400 Multiplication-Sign 400 mm{sup 2}. The composite dosimetric data of the three units are presented in this work. The commissioning of intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), image-guided radiation therapy, and gating systems are also illustrated. Critical considerations of P{sub ion} of FFF photon beams and small field dosimetric measurements were investigated. Results: The authors found all PDDs and profiles matched well among the three machines. Beam data were quantitatively compared and combined through average to yield composite beam data. The discrepancies among the machines were quantified using standard deviation (SD). The mean SD of the PDDs among the three units is 0.12%, and the mean SD of the profiles is 0.40% for 10 MV FFF open fields. The variations of P{sub ion} of the chamber CC13 is 1.2 {+-} 0.1% under 6 MV FFF and 2.0 {+-} 0.5% under 10 MV FFF from dmax to the 18 cm-off-axis point at 35 cm depth under 40 Multiplication-Sign 40 cm{sup 2}. The mean penumbra of crossplane flattened photon beams at collimator angle of 0 Degree-Sign is measured from 5.88 {+-} 0.09 to 5.99 {+-} 0.13 mm from 4 to 15 MV at 10 cm depth of 100 Multiplication-Sign 100 mm{sup 2}. The mean penumbra of crossplane beams at collimator angle of 0 Degree-Sign is measured as 3.70 {+-} 0.21 and 4.83 {+-} 0.04 mm for 6 MV FFF and 10 MV FFF, respectively, at 10 cm depth with a field size of 5 Multiplication-Sign 5 cm{sup 2}. The end-to-end test procedures of both IMRT and VMAT were performed for various energy modes. The mean ion chamber measurements of three units showed less than 2% between measurement and calculation; the mean MultiCube ICA measurements demonstrated over 90% pixels passing gamma analysis (3%, 3 mm, 5% threshold). The imaging dosimetric data of KV planar imaging and CBCT demonstrated improved consistency with vendor specifications and dose reduction for certain imaging protocols. The gated output verification showed a discrepancy of 0.05% or less between gating radiation delivery and nongating radiation delivery. Conclusions: The commissioning data indicated good consistency among the three TB-LINAC units. The commissioning data provided us valuable insights and reliable evaluations on the characteristics of the new treatment system. The systematically measured data might be useful for future reference.

07 ISOTOPE AND RADIATION SOURCES↗

Beam Test Results of the GlueX Forward Calorimeter

GlueX is an experiment to begin running in the near future at Jefferson Lab. Our research group is responsible for the forward calorimeter (FCAL) that is designed to measure the energy of photons produced from the decays of mesons. Recently, we conducted a beam test at Jefferson Lab using a prototype of the FCAL. Its goal was to experimentally verify the energy resolution of the FCAL as a function of beam energy. The prototype was tested with recoil electrons ranging in energy from 113MeV to 277MeV. We obtained the resolution by comparing the reconstructed energy to the known energy. In addition, we corrected our measured resolution for multiple scattering and energy loss based on a GEANT4 simulation of the prototype. Another important goal of the beam test was to measure the timing resolution of the channels on our flash analog to digital converters (fADCs). For GlueX, we need to require the timing resolution to be much less than the bunch spacing (2ns). The results of our studies indicate that the energy resolution of the FCAL is consistent with our predictions. We also found the timing resolution as a function of signal size and the results agreed with a similar study. For signals of about at least 75mV, the timing resolution achieved was significantly lower than 2ns.

Bauer, Kevin↗

Filament-induced breakdown spectroscopy with structured beams

Filament-induced ablation represents an attractive scheme for long-range material identification via optical spectroscopy. However, the delivery of laser energy to the target can be severely hindered by the stochastic nature of multiple-filamentation, ionization of ambient gas, and atmospheric turbulence. In order to mitigate some of these adverse effects, we examine the utility of beam shaping for femtosecond filament-induced breakdown spectroscopy with Gaussian and structured (Laguerre-Gaussian, Airy, and Bessel-Gaussian) beams in the nonlinear regime. Interaction of filaments with copper, zinc, and brass targets was studied by recording axially-resolved broadband emission from the filament-induced plasma. The laser-solid coupling efficacy was assessed by inferring thermodynamic parameters such as excitation temperature and electron density. While under our experimental conditions the ablation rate with Gaussian- and Laguerre-Gaussian beams is found to be similar, the Airy and Bessel-Gaussian beams offer the advantage of longitudinally extended working zones. These results provide insights into potential benefits of structuring ultrafast laser beams for standoff sensing applications.

47 OTHER INSTRUMENTATION↗