Search NASA⌕ Search

SEARCH · Search NASA

Results for “object tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Observing Mode Attitude Controller for the Lunar Reconnaissance Orbiter

The Lunar Reconnaissance Orbiter (LRO) mission is the first of a series of lunar robotic spacecraft scheduled for launch in Fall 2008. LRO will spend at least one year in a low altitude polar orbit around the Moon, collecting lunar environment science and mapping data to enable future human exploration. The LRO employs a 3-axis stabilized attitude control system (ACS) whose primary control mode, the "Observing mode", provides Lunar Nadir, off-Nadir, and Inertial fine pointing for the science data collection and instrument calibration. The controller combines the capability of fine pointing with that of on-demand large angle full-sky attitude reorientation into a single ACS mode, providing simplicity of spacecraft operation as well as maximum flexibility for science data collection. A conventional suite of ACS components is employed in this mode to meet the pointing and control objectives. This paper describes the design and analysis of the primary LRO fine pointing and attitude re-orientation controller function, known as the "Observing mode" of the ACS subsystem. The control design utilizes quaternion feedback, augmented with a unique algorithm that ensures accurate Nadir tracking during large angle yaw maneuvers in the presence of high system momentum and/or maneuver rates. Results of system stability analysis and Monte Carlo simulations demonstrate that the observing mode controller can meet fine pointing and maneuver performance requirements.

Calhoun, Philip C.↗

Conjunction Assessment Late-Notice High-Interest Event Investigation: Space Weather Aspects

Late-notice events usually driven by large changes in primary (protected) object or secondary object state. Main parameter to represent size of state change is component position difference divided by associated standard deviation (epsilon divided by sigma) from covariance. Investigation determined actual frequency of large state changes, in both individual and combined states. Compared them to theoretically expected frequencies. Found that large changes ( (epsilon divided by sigma) is greater than 3) in individual object states occur much more frequently than theory dictates. Effect is less pronounced in radial components and in events with probability of collision (Pc) greater than 1 (sup -5) (1e-5). Found combined state matched much closer to theoretical expectation, especially for radial and cross-track. In-track is expected to be the most vulnerable to modeling errors, so not surprising that non-compliance largest in this component.

Conjunction↗

Land ice height-retrieval algorithm for NASA's ICESat-2 photon-counting laser altimeter

The Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) and its sole scientific instrument, the Advanced Topographic Laser Altimeter System (ATLAS), was launched on 15 September 2018 with a primary goal of measuring changes in the surface of the Earth's land ice (glaciers and ice sheets). ATLAS is a photon-counting laser altimeter, which records the transit time of individual photons in order to reconstruct surface height along track. The ground-track pattern repeats every 91 days such that changes in ice sheet surface height can be estimated through time. In this paper, we describe the set of algorithms that have been developed for ICESat-2 to retrieve ice sheet surface height from the geolocated photons for the Land Ice Along-Track Height Product (ATL06), and demonstrate their output and performance using a synthetic dataset over various land-ice surfaces and under different cloud conditions. We show that the ATL06 algorithm is expected to perform at the level required to meet the ICESat-2 science objectives for land ice.

ICESat-2↗

Evaluating CERES TOA Fluxes using ARISE aircraft observations

Uncertainty in observations of top-of-atmosphere (TOA) radiation fluxes are larger in the Arctic than in other regions. The magnitude of these uncertainties limit our understanding of the Arctic surface energy budget and its variability. The significant uncertainties are due to the low sun angles and wide range of highly reflecting, anisotropic, and highly heterogeneous surface conditions. Therefore, quantifying, attributing, and reducing Arctic TOA radiative flux uncertainty enables a better understanding of the rapidly changing Arctic. To advance this goal, we compare the Cloud and Earth’s Radiant Energy System (CERES) TOA radiative fluxes with measurements from the Arctic Radiation-IceBridge Sea and Ice Experiment (ARISE) flow in September 2014. A key objective of ARISE was to evaluate and attribute uncertainty in CERES footprint and gridded TOA radiative fluxes. In this study, we first compare the CERES TOA flux with those obtained from the broadband radiometer measurements from the aircraft using instantaneously matched footprint with the flight track and as the hourly gridded fluxes. This comparison indicates an agreement within uncertainty in the longwave (2 Wm-2 ) for all five grid boxes and agreement in the shortwave (10 Wm-2) for four-out-of-five grid boxes. While not a statistically significant results given the small sample size, the hourly, gridded and the instantaneously matched footprint comparison suggest a -10 Wm-2 bias for CERES in the shortwave. To explore whether this is a robust feature or a statistical artifact, we quantify the individual sources of uncertainty in the differences (temporal and spatial sampling differences, scene evolution, accuracy, angular distribution models, and scene id) to see if any of these differences account for the shortwave bias.

CERES↗

SU-A-BRA-01: Introduction

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-A-BRA-03: Creative Stimulation: A Flexible Hands-On Approach to Building a Deeper Understanding of Critical Concepts in Radiation Physics

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-A-BRA-04: Incorporating Active Learning Into Medical Physics Education

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-A-BRA-05: Panel Discussion

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-A-BRA-00: Education Council Symposium: Revitalizing Your Medical Physics Classroom: Some Examples and Thoughts from the Trenches

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-A-BRA-02: Making the Most of a One Hour Lecture with Alternative Teaching Methodologies: Implementing Project-Based and Flipped Learning

Vic Montemayor - No one has been more passionate about improving the quality and effectiveness of the teaching of Medical Physics than Bill Hendee. It was in August of 2008 that the first AAPM Workshop on Becoming a Better Teacher of Medical Physics was held, organized and run by Bill Hendee. This was followed up in July of 2010 with a summer school on the same topic, again organized by Bill. There has been continued interest in alternate approaches to teaching medical physics since those initial gatherings. The momentum established by these workshops is made clear each year in the annual Innovation in Medical Physics Education session, which highlights work being done in all forms of medical physics education, from one-on-one residencies or classroom presentations to large-scale program revisions and on-line resources for international audiences. This symposium, presented on behalf of the Education Council, highlights the work of three finalists from past Innovation in Education sessions. Each will be presenting their approaches to and innovations in teaching medical physics. It is hoped that audience members interested in trying something new in their teaching of medical physics will find some of these ideas and approaches readily applicable to their own classrooms. Rebecca Howell - The presentation will discuss ways to maximize classroom learning, i.e., increasing the amount of material covered while also enhancing students’ understanding of the broader implications of the course topics. Specifically, the presentation will focus on two teaching methodologies, project based learning and flip learning. These teaching methods will be illustrated using an example of graduate medical physics course where both are used in conjunction with traditional lectures. Additionally, the presentation will focus on our experience implementing these methods including challenges that were overcome. Jay Burmeister - My presentation will discuss the incorporation of active learning techniques into a traditional medical physics classroom course. I will describe these techniques and how they were implemented as well as student performance before and after implementation. Student feedback indicated that these course changes improved their ability to actively assimilate the course content, thus improving their understanding of the material. Shahid Naqvi - My talk will focus on ways to help students visualize crucial concepts that lie at the core of radiation physics. Although particle tracks generated by Monte Carlo simulations have served as an indispensable visualization tool, students often struggle to resolve the underlying physics from a simultaneous jumble of tracks. We can clarify the physics by “coding” the tracks, e.g., by coloring the tracks according to their “starting” or “crossing” regions. The regionally-coded tracks when overlaid with dose distributions help the students see the elusive connection between dose, kerma and electronic disequilibrium. Tracks coded according to local energy or energy-loss rate can illustrate the need for stopping power corrections in electron beams and explain the Bragg peak in a proton beam. Coding tracks according to parent interaction type and order can clarify the often misunderstood distinction between primary and scatter dose. The students can thus see the “whole” simultaneously with the “sum of the parts,” which enhances their physical insight and creates a sustainable foundation for further learning. After the presentations the speakers and moderator will be open to questions and discussion with the audience members. Learning Objectives: Be able to explain Project-Based Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain Flipped Learning and how can it be incorporated into a Medical Physics classroom. Be able to explain active-learning strategies for the teaching of Medical Physics. Be able to explain how Monte Carlo simulations can be used to deepen a student’s understanding of radiation physics and dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Two- and three-dimensional folding of thin film single-crystalline silicon for photovoltaic power applications

Fabrication of 3D electronic structures in the micrometer-to-millimeter range is extremely challenging due to the inherently 2D nature of most conventional wafer-based fabrication methods. Self-assembly, and the related method of self-folding of planar patterned membranes, provide a promising means to solve this problem. Here, we investigate self-assembly processes driven by wetting interactions to shape the contour of a functional, nonplanar photovoltaic (PV) device. A mechanics model based on the theory of thin plates is developed to identify the critical conditions for self-folding of different 2D geometrical shapes. This strategy is demonstrated for specifically designed millimeter-scale silicon objects, which are self-assembled into spherical, and other 3D shapes and integrated into fully functional light-trapping PV devices. The resulting 3D devices offer a promising way to efficiently harvest solar energy in thin cells using concentrator microarrays that function without active light tracking systems.

14 SOLAR ENERGY↗

THE THOMSON SURFACE. II. POLARIZATION

The solar corona and heliosphere are visible via sunlight that is Thomson-scattered off free electrons, yielding a radiance against the celestial sphere. In this second part of a three-article series, we discuss linear polarization of this scattered light parallel and perpendicular to the plane of scatter in the context of heliospheric imaging far from the Sun. The difference between these two radiances (pB) varies quite differently with scattering angle, compared to the sum that would be detected in unpolarized light (B). The difference between these two quantities has long been used in a coronagraphic context for background subtraction and to extract some three-dimensional information about the corona; we explore how these effects differ in the wider-field heliospheric imaging case where small-angle approximations do not apply. We develop an appropriately simplified theory of polarized Thomson scattering in the heliosphere, discuss signal-to-noise considerations, invert the scattering equations analytically to solve the three-dimensional object location problem for small objects, discuss exploiting polarization for background subtraction, and generate simple forward models of several classes of heliospheric feature. We conclude that pB measurements of heliospheric material are much more localized to the Thomson surface than are B measurements, that the ratio pB/B can be used to track solar wind features in three dimensions for scientific and space weather applications better in the heliosphere than corona, and that,as an independent measurement of background signal, pB measurements may be used to reduce the effect of background radiances including the stably polarized zodiacal light.

79 ASTRONOMY AND ASTROPHYSICS↗

NIF Projects Controls and Information Systems Software Quality Assurance Plan

Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

42 ENGINEERING↗

Suggested Record-Keeping Procedures for DDOE Energy Programs

Sixteen different programs designed to increase energy efficiency and reduce the energy cost burden for District of Columbia residents, businesses, and non-profit organizations are currently provided by the District Department of the Environment's (DDOE's) Energy Office. In the spring of 2008, DDOE asked Oak Ridge National Laboratory (ORNL) to provide assistance in its ongoing efforts to track the progress of those programs. Effective record-keeping can provide information to help managers improve their programs, be very useful in preparing quarterly reports documenting program achievements, and facilitate the performance of periodic evaluations that measure how well the various programs are achieving their objectives. The first major task in this study was to review existing documents describing DDOE's energy programs, to become familiar with the purpose and procedures of each one. The relevant documents included existing program evaluation plans, recent evaluations of DDOE's energy programs, relevant Public Service Commission orders, local regulatory filings, filings by other interested parties, and evaluation-related documents from other states. The next step was to conduct in-depth interviews with all DDOE energy program managers to obtain detailed information on each program's information needs, existing record-keeping procedures, and data collection capabilities. Those interviews were followed by discussions with DDOE evaluation staff to identify their key information requirements. Based on program goals and activities, evaluation and reporting needs, and other relevant factors revealed through the document review and in-depth interviews, we identified key items for each program on which the record-keeping effort should focus. The frequency of data collection was determined by the needs of program managers and evaluators as well as by reporting requirements. Appropriate analytical approaches to use with the data collected for each program were identified based on the evaluation-related documents reviewed and the experience of ORNL evaluators. Ideas on data entry and storage procedures were provided by interviews with information technology experts and a past ORNL examination of U.S. Department of Energy record-keeping practices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Phoebe - Voyager 2 observations

Voyager 2 images of Phoebe obtained over a period of 24 hours provide information on the size, rotation rate, surface markings, and photometric properties of this mysterious object. Phoebe is approximately equidimensional: its longest diameter, about 230 km, is only 10 percent greater than the shortest-diameter (about 210 km). A prograde-rotation period of 9.4 + or - 0.2 hours was determined from both the disk-integrated light curve and by tracking individual markings. Because of the limited resolution of the images (11 pixels across the disk) crater counts cannot be made. The geometric albedo of Phoebe is longitudinally variable from 0.046 to 0.060 (clear filter, lambda = 0.47 micron). The most prominent surface markings are brighter patches at high northern and southern latitudes that have reflectances as much as 50 percent greater than the dark, bland areas. These patches are scattered and do not appear to constitute polar caps. The Voyager color data agree with earlier ground-based spectra that show that Phoebe has a flatter spectrum than does the dark side of Iapetus; this observation is not consistent with simple contamination of Iapetus by debris from Phoebe.

Thomas, P.↗

The accuracy of altimetric surfaces

Estimates of the shape of the sea surface as determined from satellite altimeters have become of increasing importance in geophysics, geodesy and physical oceanography. The most effective error reduction procedures used in producing these surfaces have been some version of a crossing-arc analysis. The problem with this procedure is the absence of an easy means of evaluating the noise structure of the final result. By recasting the problem as one of objective mapping (optimal estimation) the error reduction is optimized and an explicit estimate is obtained of the wave-number structure of the final altimetric surface. Examples, suitable to a small computer, have been generated to show that the error reduction along the sub-satellite tracks is very great, with most of the residual lying in long wavelengths.

Wunsch, C.↗

A proven knowledge-based approach to prioritizing process information

Many space-related processes are highly complex systems subject to sudden, major transients. In any complex process control system, a critical aspect is rapid analysis of the changing process information. During a disturbance, this task can overwhelm humans as well as computers. Humans deal with this by applying heuristics in determining significant information. A simple, knowledge-based approach to prioritizing information is described. The approach models those heuristics that humans would use in similar circumstances. The approach described has received two patents and was implemented in the Alarm Filtering System (AFS) at the Idaho National Engineering Laboratory (INEL). AFS was first developed for application in a nuclear reactor control room. It has since been used in chemical processing applications, where it has had a significant impact on control room environments. The approach uses knowledge-based heuristics to analyze data from process instrumentation and respond to that data according to knowledge encapsulated in objects and rules. While AFS cannot perform the complete diagnosis and control task, it has proven to be extremely effective at filtering and prioritizing information. AFS was used for over two years as a first level of analysis for human diagnosticians. Given the approach's proven track record in a wide variety of practical applications, it should be useful in both ground- and space-based systems.

Corsberg, Daniel R.↗

Combined infrared and analytical electron microscope studies of interplanetary dust particles

Ultramicrotomed thin sections (less than 100 nm thick) of eight chondritic interplanetary dust particles (IDPs) were studied by analytical electron microscopy and IR microspectroscopy with the objective of identifying IDPs or their specific components with IR spectral transmission characteristics at 10 microns similar to those of comets. Two IDPs are identified whose silicate emission characteristics between 8 and 12 microns are similar to those of comets Halley and Bradfield. Implanted solar flare tracks and sputtered rims resulting from solar wind damage suggest that the minerology and petrography of these IDPs have not been significantly perturbed since ejection from their parent bodies.

Bradley, J. P.↗