Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Structural Studies of Amorphous Materials by Fluctuation Electron Microscopy

Fluctuation Electron Microscopy (FEM) is a technique that examines the fluctuations in electron scattering across a uniformly thin amorphous sample. The statistics of the intensity fluctuations, mean and variance, reveal any underlying medium-range order present in the structure. The goals of this project were: (1) To determine the fundamentals of the scattering physics that gives rise to the variance signal in fluctuation electron microscopy (FEM); (2) To use these discoveries to find ways to quantify FEM; (3) To apply the FEM method to interesting and technologically important families of amorphous materials, particularly those with important applications in energy-related processes. Excellent progress was made in items (1) and (2). In stage (3) we did not examine the metamict zircons, as proposed. Instead, we examined films of polycrystalline and amorphous semi-conducting diamond. Significant accomplishments are: (1) A Reverse Monte Carlo procedure was successfully implemented to invert FEM data into a structural model. This is computer-intensive, but it demonstrated that diffraction and FEM data from amorphous silicon are most consistent with a paracrystallite model. This means that there is more diamond-like topology present in amorphous silicon than is predicted by the continuous random network model. (2) There is significant displacement decoherence arising in diffraction from amorphous silicon and carbon. The samples are being bombarded by the electron beam and atoms do not stay still while being irradiated – much more than was formerly understood. The atom motions cause the destructive and constructive interferences in the diffraction pattern to fluctuate with time, and it is the time-averaged speckle that is being measured. The variance is reduced by a factor m, 4 ≤ m ≤ 1000, relative to that predicted by kinematical scattering theory. (3) Speckle intensity obeys a gamma distribution, where the mean intensity $ \overline{I}\ $ and m are the two parameters governing the shape of the gamma distribution profile. m is determined by the illumination spatial coherence, which is normally very high, and mostly by the displacement decoherence within the sample. (4) Amorphous materials are more affected by the electron beam than are crystalline materials. Different samples exhibit different disruptibility, as measured by the effective values of m that fit the data. (5) Understanding the origin of the displacement decoherence better should lead to efficient methods for computing the observed variance from amorphous materials.

36 MATERIALS SCIENCE↗

SU-E-J-158: Experimental Investigation of Proton Radiography Based On Time-Resolved Dose Measurements

Purpose: To use proton radiography for i) in-vivo range verification of the brain fields of medulloblastoma patients in order to reduce the exit dose to the cranial skin and thus the risk of permanent alopecia; ii) for performing patient specific optimization of the calibration from CT-Hounsfield units to proton relative stopping power in order to minimize uncertainties of proton rang Methods: We developed and tested a prototype proton radiography system based on a single-plane scintillation screen coupled with a fast CCD camera (1ms sampling rate, 0.29x0.29 mm{sup 2} pixel size, 30×30 cm{sup 2} field of view). The method is based on the principle that, for passively scattered beams, the radiological depth of any point in the plateau of a spread-out Bragg-Peak (SOBP) can be inferred from the time-pattern of the dose rate measurements. We performed detector characterization measurements using complex-shape homogeneous phantoms and an Alderson phanto Results: Detector characterization tests confirmed the robustness of the technique. The results of the phantom measurements are encouraging in terms of achievable accuracy of the water equivalent thickness. A technique to minimize the degradation of spatial resolution due to multiple Coulomb scattering is discussed. Our novel radiographic technique is rapid (100 ms) and simultaneous over the whole field. The dose required to produce one radiograph, with the current settings, is ∼3 cG Conclusion: The results obtained with this simple and innovative radiography method are promising and motivate further development of technique. The system requires only a single-plane 2D dosimeter and it uses the clinical beam for a fraction of second with low dose to the patient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Advances in Small Angle X-ray Scattering for Superlattice Study

Small-angle x-ray scattering is used for the structure determination of superlattice for its superior resolution, nondestructive nature, and high penetration power of x rays. With the advent of high brilliance x-ray sources and innovative computing algorithms, there have been notable advances in small angle x-ray scattering analysis of superlattices. High brilliance x-ray beams have made data analyses less model-dependent. Additionally, novel data acquisition systems are faster and more competitive than ever before, enabling a more accurate mapping of the superlattices' reciprocal space. Fast and high-throughput computing systems and algorithms also make possible advanced analysis methods, including iterative phasing algorithms, non-parameterized fitting of scattering data with molecular dynamics simulations, and the use of machine learning algorithms. As a result, solving nanoscale structures with high resolutions has become an attainable task. In this review, we highlight new developments in the field and introduce their applications for the analysis of nanoscale ordered structures, including nanoparticle supercrystals, nanoscale lithography patterns, and supramolecular self-assemblies. Particularly, we highlight the reciprocal space mapping techniques and the use of iterative phase retrieval algorithms. We also cover coherent-beam-based small angle x-ray scattering techniques such as ptychography and ptycho-tomography in view of the traditional small angle x-ray scattering perspective.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-513: Dosimetric Validation of Spatially Fractionated Radiotherapy Using Gel Dosimetry

Purpose: Spatially fractionated radiation therapy, also known as GRID therapy, is used to treat large solid tumors by irradiating the target to a single dose of 10–20Gy through spatially distributed beamlets. We have investigated the use of a 3D gel for dosimetric characterization of GRID therapy. Methods: GRID therapy is an external beam analog of volumetric brachytherapy, whereby we produce a distribution of hot and cold dose columns inside the tumor volume. Such distribution can be produced with a block or by using a checker-like pattern with MLC. We have studied both types of GRID delivery. A cube shaped acrylic phantom was filled with polymer gel and served as a 3D dosimeter. The phantom was scanned and the CT images were used to produce two plans in Pinnacle, one with the grid block and one with the MLC defined grid. A 6MV beam was used for the plan with a prescription of 1500cGy at dmax. The irradiated phantom was scanned in a 3T MRI scanner. Results: 3D dose maps were derived from the MR scans of the gel dosimeter and were found to be in good agreement with the predicted dose distribution from the RTP system. Gamma analysis showed a passing rate of 93% for 5% dose and 2mm DTA scoring criteria. Both relative and absolute dose profiles are in good agreement, except in the peripheral beamlets where the gel measured slightly higher dose, possibly because of the changing head scatter conditions that the RTP is not fully accounting for. Our results have also been benchmarked against ionization chamber measurements. Conclusion: We have investigated the use of a polymer gel for the 3D dosimetric characterization and evaluation of GRID therapy. Our results demonstrated that the planning system can predict fairly accurately the dose distribution for GRID type therapy.

60 APPLIED LIFE SCIENCES↗

A generalized method for determining radiation patterns of aperture antennas and its application to reflector antennas

The reflector antenna may be thought of as an aperture antenna. The classical solution for the radiation pattern of such an antenna is found by the aperture integration (AI) method. Success with this method depends on how accurately the aperture currents are known beforehand. In the past, geometrical optics (GO) has been employed to find the aperture currents. This approximation is suitable for calculating the main beam and possibly the first few sidelobes. A better approximation is to use aperture currents calculated from the geometrical theory of diffraction (GTD). Integration of the GTD currents over and extended aperture yields more accurate results for the radiation pattern. This approach is useful when conventional AI and GTD solutions have no common region of validity. This problem arises in reflector antennas. Two dimensional models of parabolic reflectors are studied; however, the techniques discussed can be applied to any aperture antenna.

Paknys, J. R.↗

Light-driven nanoscale vectorial currents

Controlled charge flows are fundamental to many areas of science and technology, serving as carriers of energy and information, as probes of material properties and dynamics and as a means of revealing or even inducing broken symmetries. Emerging methods for light-based current control offer particularly promising routes beyond the speed and adaptability limitations of conventional voltage-driven systems. However, optical generation and manipulation of currents at nanometre spatial scales remains a basic challenge and a crucial step towards scalable optoelectronic systems for microelectronics and information science. Here we introduce vectorial optoelectronic metasurfaces in which ultrafast light pulses induce local directional charge flows around symmetry-broken plasmonic nanostructures, with tunable responses and arbitrary patterning down to subdiffractive nanometre scales. Local symmetries and vectorial currents are revealed by polarization-dependent and wavelength-sensitive electrical readout and terahertz (THz) emission, whereas spatially tailored global currents are demonstrated in the direct generation of elusive broadband THz vector beams 17 . We show that, in graphene, a detailed interplay between electrodynamic, thermodynamic and hydrodynamic degrees of freedom gives rise to rapidly evolving nanoscale driving forces and charge flows under the extremely spatially and temporally localized excitation. These results set the stage for versatile patterning and optical control over nanoscale currents in materials diagnostics, THz spectroscopies, nanomagnetism and ultrafast information processing.

36 MATERIALS SCIENCE↗

Poisson's spot with molecules

In the Poisson-spot experiment, waves emanating from a source are blocked by a circular obstacle. Due to their positive on-axis interference an image of the source (the Poisson spot) is observed within the geometrical shadow of the obstacle. In this paper we report the observation of Poisson's spot using a beam of neutral deuterium molecules. The wavelength independence and the weak constraints on angular alignment and position of the circular obstacle make Poisson's spot a promising candidate for applications ranging from the study of large molecule diffraction to patterning with molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lift-off patterning processing employing energetically-stimulated local removal of solid-condensed-gas layers

The invention provides a method for forming a patterned material layer on a structure, by condensing a vapor to a solid condensate layer on a surface of the structure and then localized removal of selected regions of the condensate layer by directing a beam of energy at the selected regions, exposing the structure at the selected regions. A material layer is then deposited on top of the solid condensate layer and the exposed structure at the selected regions. Then the solid condensate layer and regions of the material layer that were deposited on the solid condensate layer are removed, leaving a patterned material layer on the structure.

36 MATERIALS SCIENCE↗

Lift-off patterning processes employing energetically-stimulated local removal of solid-condensed-gas layers

The invention provides a method for forming a patterned material layer on a structure, by condensing a vapor to a solid condensate layer on a surface of the structure and then localized removal of selected regions of the condensate layer by directing an ion beam at the selected regions, exposing the structure at the selected regions. A material layer is then deposited on top of the solid condensate layer and the exposed structure at the selected regions. Then the solid condensate layer and regions of the material layer that were deposited on the solid condensate layer are removed, leaving a patterned material layer on the structure.

Branton, Daniel↗

Investigation of signal characteristics and charge sharing in AC-LGADs with laser and test beam measurements

AC-LGADs, also referred to as resistive silicon detectors, are a recent development of low-gain avalanche detectors (LGADs), based on a sensor design where the multiplication layer and n + contact are continuous, and only the metal layer is patterned. In AC-LGADs, the signal is capacitively coupled from the continuous, resistive n + layer over a dielectric to the metal electrodes. Therefore, the spatial resolution is not only influenced by the electrode pitch, but also the relative size of the metal electrodes. Signal propagation between the metallized areas and charge sharing between electrodes plays a larger role in these detectors than in conventional silicon sensors read out in DC mode. AC-LGADs from two manufacturers were studied in beam tests and with infrared laser scans. The impact of n + layer resistivity and metal electrode pitch on the charge sharing and achievable position resolution is shown. For strips with 100 μm pitch, a resolution of ¡ 5 μm can be reached. Additionally, the charge sharing between neighboring strips is investigated in more detail, indicating the induction of signal charge and subsequent re-sharing over the n + layer. Furthermore, an approach to identify signal sharing over large distances is presented.

47 OTHER INSTRUMENTATION↗

Self-organized metallic nanoparticle and nanowire arrays from ion-sputtered silicon templates

We demonstrate a production method for self-organized arrays of metal nanoparticles and aligned nanowires. Ion beam-sputtered Si/SiO2 substrates are used as templates for metallic vapor deposition, forming aligned arrays of 5-20 nm silver and cobalt nanoparticles with a period of 35 nm. The 20 nm diameter cobalt nanowires with lengths in excess of a micrometer are produced under appropriate conditions. All processing steps can be integrated into a single vacuum chamber and performed in a matter of minutes at mild temperatures. This inherently scalable technique can be extended to a range of substrate materials, array patterns, and nanoparticle materials.

36 MATERIALS SCIENCE↗

Interface structures of inclined ZnO thin film on (0 1 1)-MgO substrate with bulk-like optical properties

Combining different phase structure materials with unique properties to design novel devices plays a significant role in the development of modern electronics. Here, we explore the characteristics of this type of complex interface and epitaxy structures based on the coupling between hexagonal ZnO film and cubic MgO substrate. The ZnO film was prepared by the molecular beam epitaxy technique on the MgO (0 1 1) substrate. The analysis results from the in situ reflection high energy electron diffraction patterns, X-ray diffraction (XRD)-pole figures and high resolution transmission electron microscopy images demonstrate that the film exhibits two-fold symmetry domains with a growth direction deviated from c-axis at about 31º along the [0 1 0] MgO or [0 $\bar{1}$ 0] MgO azimuth. Despite the intertwined diffusion from Zn and Mg atoms in the interface, which is the possible origin of a blue shift of about 0.083 eV in the Photoluminescence (PL) spectrum, the inclined film shows a full width at half maximum value that is close to the reported value from the high quality film. Finally, this work hopefully provides useful insights to the design and exploration of the novel optoelectronic devices that involve the integration of materials with different structure and different properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Efficient laser-driven proton acceleration from cylindrical and planar cryogenic hydrogen jets

We report on recent experimental results deploying a continuous cryogenic hydrogen jet as a debris-free, renewable laser-driven source of pure proton beams generated at the 150 TW ultrashort pulse laser Draco. Efficient proton acceleration reaching cut-off energies of up to 20 MeV with particle numbers exceeding 109 particles per MeV per steradian is demonstrated, showing for the first time that the acceleration performance is comparable to solid foil targets with thicknesses in the micrometer range. Two different target geometries are presented and their proton beam deliverance characterized: cylindrical (Ø 5 μm) and planar (20 μm × 2 μm). In both cases typical Target Normal Sheath Acceleration emission patterns with exponential proton energy spectra are detected. Significantly higher proton numbers in laser-forward direction are observed when deploying the planar jet as compared to the cylindrical jet case. As a result, this is confirmed by two-dimensional Particle-in-Cell (2D3V PIC) simulations, which demonstrate that the planar jet proves favorable as its geometry leads to more optimized acceleration conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near-field radiative thermal transfer between a nanostructured periodic material and a planar substrate

This paper provides a method based on rigorous coupled wave analysis for the calculation of the radiative thermal conductance between a layer that is patterned with arbitrary, periodically repeating features and a planar substrate. This method is applied to study the transfer from an array of beams with a rectangular cross section. Herein the impact of the structure size and spacing on the thermal conductance are investigated. These calculations are compared to an effective medium theory, which becomes increasingly accurate as the structure sizes fall well below the relevant resonance wavelengths of materials and structures. Moreover, comparisons are made with a modified proximity approximation and the far-field approximation, which become valid for small and large spacings, respectively. Results show that new levels of control over the magnitude and spectral contributions to thermal conductance can be achieved with corrugated structures relative to planar ones. Specifically, we show for SiC arrays with rectangular cross sections and with the same filling fraction, that the use of a smaller periodicity leads to a lowered far-field thermal transfer and an increased near-field thermal transfer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Throughput Data Processing at FRIB Using ESnet

Real-time or nearly real-time (nearline) data processing methods are critical tools as detector technologies and data acquisition (DAQ) systems allow for higher data rates and volumes. The introduction of the energy sciences network (ESnet), a U.S. Department of Energy (DOE) supported high-speed network for scientific research, creates opportunities to leverage the computing power of DOE facilities like the National Energy Research Scientific Computing Center (NERSC). As a first step toward realizing a DOE Office of Science Integrated Research Infrastructure (IRI) pattern, an automated workflow was developed to remotely process data obtained from a nuclear physics experiment at the Facility for Rare Isotope Beams (FRIB) at NERSC with data transferred between FRIB and NERSC over ESnet. The workflow demonstrated the ability to process one week’s worth of experimental data in approximately 90 min and was used successfully for nearline analysis during a recently completed FRIB experiment. Here, a summary of the workflow development and results of recent demonstrations will be presented.

Data processing↗

Dual-etalon, cavity-ring-down, frequency comb spectroscopy.

The 'dual etalon frequency comb spectrometer' is a novel low cost spectometer with limited moving parts. A broad band light source (pulsed laser, LED, lamp ...) is split into two beam paths. One travels through an etalon and a sample gas, while the second arm is just an etalon cavity, and the two beams are recombined onto a single detector. If the free spectral ranges (FSR) of the two cavities are not identical, the intensity pattern at the detector with consist of a series of heterodyne frequencies. Each mode out of the sample arm etalon with have a unique frequency in RF (radio-frequency) range, where modern electronics can easily record the signals. By monitoring these RF beat frequencies we can then determine when an optical frequencies is absorbed. The resolution is set by the FSR of the cavity, typically 10 MHz, with a bandwidth up to 100s of cm{sup -1}. In this report, the new spectrometer is described in detail and demonstration experiments on Iodine absorption are carried out. Further we discuss powerful potential next generation steps to developing this into a point sensor for monitoring combustion by-products, environmental pollutants, and warfare agents.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Effect of Collimation on Diffraction Signal-to-Background Ratios at a Neutron Diffractometer

High diffraction signal-to-background ratios (SBRs), the ratios of diffraction peak integrated intensity over its background intensity, are desired for a neutron diffractometer to acquire good statistics for diffraction pattern measurements and subsequent data analysis. For a given detector, while the diffraction peak signals primarily depend on the characteristics of neutron beam and sample coherent scattering, the background largely originates from the sample incoherent scattering and the scattering from the instrument space. In this work, we investigated the effect of collimation on neutron diffraction SBRs of Si powder measurements using one high-angle area detector bank coupled with six different collimation configurations in a large and complex instrument space at the engineering materials diffractometer VULCAN, SNS, ORNL. The results revealed that the diffraction SBRs can be significantly improved by a proper coarse collimator that leaves no gap between the detector and the collimator, and the improvement of SBRs by a fine radial collimator was remarkable with a proper coarse collimator in place but not distinguishable without one. It was also found that the diffraction SBRs were not effectively improved by adding neutron absorbing element boron to the fine radial collimator body, which indicates that either the absorption of secondary scattered neutrons by the added boron is insignificant or the collimator base material (resin and ABS) alone attenuates background scattering sufficiently. These findings could serve as a useful reference for diffractometer developers and/or operators to optimize their collimation to achieve higher diffraction SBRs.

Yu, Dunji↗

The Pointing Self-calibration Algorithm for Aperture Synthesis Radio Telescopes

This paper is concerned with algorithms for calibration of direction-dependent effects (DDE) in aperture synthesis radio telescopes (ASRT). After correction of direction-independent effects (DIE) using self-calibration, imaging performance can be limited by the imprecise knowledge of the forward gain of the elements in the array. In general, the forward gain pattern is directionally dependent and varies with time due to a number of reasons. Some factors, such as rotation of the primary beam with Parallactic Angle for Azimuth–Elevation mount antennas are known a priori. Some, such as antenna pointing errors and structural deformation/projection effects for aperture-array elements cannot be measured a priori. Thus, in addition to algorithms to correct for DD effects known a priori, algorithms to solve for DD gains are required for high dynamic range imaging. Here, we discuss a mathematical framework for antenna-based DDE calibration algorithms and show that this framework leads to computationally efficient optimal algorithms that scale well in a parallel computing environment. As an example of an antenna-based DD calibration algorithm, we demonstrate the Pointing SelfCal (PSC) algorithm to solve for the antenna pointing errors. Our analysis show that the sensitivity of modern ASRT is sufficient to solve for antenna pointing errors and other DD effects. We also discuss the use of the PSC algorithm in real-time calibration systems and extensions for antenna Shape SelfCal algorithm for real-time tracking and corrections for pointing offsets and changes in antenna shape.

79 ASTRONOMY AND ASTROPHYSICS↗