Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

The Hopkins ultraviolet telescope

The Shuttle is scheduled to carry the Hopkins UV Telescope (HUT) aloft in 1986. HUT will be one of three telescopes on the mission and will be sensitive to the 450-1800 A interval. Its primary goals will be observations of Halley's Comet, the planets, distant galaxies and quasars. It will be controlled by Spacelab personnel and features a 0.9 m primary mirror, a spectrograph on the focal plane, and an Si intensified image television camera for on-line image monitoring. The main component of the spectrograph will be a 1024 channel self-scanning Reticon photodiode array coupled by optic fibers to the microchannel detector plates. HUT is presently undergoing qualification testing.

Davidsen, A. F.↗

Computer-generated 3D ultrasound images of the carotid artery

A method is under development to measure carotid artery lesions from a computer-generated three-dimensional ultrasound image. For each image, the position of the transducer in six coordinates (x, y, z, azimuth, elevation, and roll) is recorded and used to position each B-mode picture element in its proper spatial position in a three-dimensional memory array. After all B-mode images have been assembled in the memory, the three-dimensional image is filtered and resampled to produce a new series of parallel-plane two-dimensional images from which arterial boundaries are determined using edge tracking methods.

Selzer, Robert H.↗

Wideband arrays with variable element sizes

A new planar array architecture based on adding half-sized elements in between the other elements in order to extend the frequency by one octave is proposed and validated. This wideband array with variable element sizes (WAVES) antenna is shown by calculations and by measurements using Archimedean spirals to be the elements necessary to maintain a simple clean mainbeam and principal plane sidelobes below about -10 dB over two octaves. In spite of using a test antenna with a simple parallel feed and no impedance matching or isolation, the agreement between predicted and measured results is good.

Shively, D. G.↗

N2 Lyman-Birge-Hopfield dayglow from ATLAS 1

Spectral measurements of the far ultraviolet dayglow were made from the ATLAS 1 shuttle mission using an intensified charge coupled device (CCD) imaging spectrometer array. The instrument imaged relatively large (177 A) segments of the spectrum simultaneously and had the capability to image altitude in the second dimension of the two-dimensional focal plane detector when the entrance slit of the instrument was oriented perpendicular to the limb of the Earth. The far ultraviolet (FUV) channel of the instrument used a CsTe photocathode rather than the more conventionally used and more solar blind CsI photocathode material. As a result, the spectra were also measured with good sensitivity at FUV wavelengths longer than 1500 A. In this paper, data are selected of specific interest to a study of the N2 Lyman-Birge-Hopfield system using two shuttle attitudes: In the first the field of view was held at a fixed tangent ray height of approximately 140 km while scanning in wavelength, providing repeated FUV spectra over a range of latitudes and allowing comparison with our thermospheric airglow model. In the second observing sequence the line of sight of the instrument was scanned down through the atmosphere but covered about 75% of the full wavelength range. This sequence allows comparison of height dependence,including O2 absorption effects, with the thermospheric model. In all cases, relatively good agreement is obtained with the model (run strictly in a predictive mode) in comparisions in which the line of sight must be intergrated along a path that spans a considerable range of conditions (height, local time, latitude, solar zenith angle). In the case of the data sets examined in this study the vibrational population distributions show mixed results. In one case the distribution agrees well with a theoretical model based on direct electron impact excitation without a significant cascade contribution. A second case indicated a lower population in nu' = 3 and a higher population in nu' = 6 than would be expected from direct impact excitation alone. This supports previous indications that conditions resulting in the cascade mechanism may not always be operative.

Torr, Marsha R.↗

Characterization of a 2-mm thick, 16x16 Cadmium-Zinc-Telluride Pixel Array

The detector under study is a 2-mm-thick, 16x16 Cadmium-Zinc-Telluride pixel array with a pixel pitch of 300 microns and inter-pixel gap of 50 microns. This detector is a precursor to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation. In addition, we discuss electric field modeling for this specific detector geometry and the role this mapping will play in terms of charge sharing and charge loss in the detector.

Gaskin, Jessica↗

The Successful Synergy of Swift and Fermi/GBM in Magnetars

The magnetar rate of discovery has increased dramatically in the last decade. Five sources were discovered in the last three years alone as a result of the very efficient synergy among three X- and .gamma-ray instruments on NASA satellites: the Swift/Burst Alert Telescope (BAT), the Fermi/Gamma ray Burst Monitor (GBM), and the Rossi X-Ray Timing Explorer; RXTE/Proportional Counter Array (PCA). To date, there are approx. 25 magnetar candidates, of which two are (one each) in the Large and Small Magellanic Cloud and the rest reside on the Galactic plane of our Milky Way. I will discuss here the main properties of the Magnetar Population and the common projects that can be achieved with the synergy of Swift and GBM.

Kouveliotou, Chryssa↗

Computational Modeling to Limit the Impact Displays and Indicator Lights Have on Habitable Volume Operational Lighting Constraints

The goal of this investigation is to determine design limitations and architectural solutions that limit the impact light from displays and indicator lamps have on the operational environment task lighting and lighting countermeasure spectrum constraints. It is concerning that this innovative architectural lighting system, could be compromised by spectrums from display systems, architectural materials, and structures that are not considered as part a full system design implementation. The introduction of many Commercial Off the Shelf (COTS) products to the spacecraft volume that contain LEDs, without consideration to the human factors and biological constraints, is another problem. Displays and indicators are a necessary part of the spacecraft and it is the goal of this research project to determine constraints and solutions that allow these systems to be integrated while minimizing how the lighting environment is modified by them. Due to the potentially broad scope of this endeavor, the project team developed constraints for the evaluation. The evaluation will be on a set of tasks that required significant exposure in the same environment while having a large chance of impacting the light spectrum the crew is expected to receive from the architectural lighting system. The team plans to use recent HRP research on "Net Habitable Volume" [1] to provide the boundary conditions for volume size. A Zemax ® lighting model was developed of a small enclosure that had high intensity overhead lighting and a standard intensity display with LED indicator arrays. The computer model demonstrated a work surface illuminated at a high level by the overhead light source compared to displays and indicators whose light is parallel to the work plane. The overhead lighting oversaturated spectral contributions from the display and indicator at the task work surface. Interestingly, when the observer looked at the displays and LEDs within the small enclosure, their spectral contribution was significant but could be reduced by reflecting overhead light from the wall(s) to the observer. Direct observation of displays and LEDs are an issue because the user's viewing area is a display, not an illuminated work surface. Since avionics command centers consume significant crew time, the tasks that seemed at higher risk for unwanted spectral contributions as an operational volume with significant quantity of displays and indicators that were either under direct observation of the crew or impacting a volume the crew may be required to sleep in.

Clark, T. E.↗

Simulation Studies of the Dielectric Grating as an Accelerating and Focusing Structure

A grating-based design is a promising candidate for a laser-driven dielectric accelerator. Through simulations, we show the merits of a readily fabricated grating structure as an accelerating component. Additionally, we show that with a small design perturbation, the accelerating component can be converted into a focusing structure. The understanding of these two components is critical in the successful development of any complete accelerator. The concept of accelerating electrons with the tremendous electric fields found in lasers has been proposed for decades. However, until recently the realization of such an accelerator was not technologically feasible. Recent advances in the semiconductor industry, as well as advances in laser technology, have now made laser-driven dielectric accelerators imminent. The grating-based accelerator is one proposed design for a dielectric laser-driven accelerator. This design, which was introduced by Plettner, consists of a pair of opposing transparent binary gratings, illustrated in Fig. 1. The teeth of the gratings serve as a phase mask, ensuring a phase synchronicity between the electromagnetic field and the moving particles. The current grating accelerator design has the drive laser incident perpendicular to the substrate, which poses a laser-structure alignment complication. The next iteration of grating structure fabrication seeks to monolithically create an array of grating structures by etching the grating's vacuum channel into a fused silica wafer. With this method it is possible to have the drive laser confined to the plane of the wafer, thus ensuring alignment of the laser-and-structure, the two grating halves, and subsequent accelerator components. There has been previous work using 2-dimensional finite difference time domain (2D-FDTD) calculations to evaluate the performance of the grating accelerator structure. However, this work approximates the grating as an infinite structure and does not accurately model a realizable structure. In this paper, we will present a 3-dimensional frequency-domain simulation of both the infinite and the finite grating accelerator structure. Additionally, we will present a new scheme for a focusing structure based on a perturbation of the accelerating structure. We will present simulations of this proposed focusing structure and quantify the quality of the focusing fields.

36 MATERIALS SCIENCE↗

Meteorological radar facility (MRF) slot conductance investigations

A preliminary meteorological radar facility (MRF) array design was completed in support of the slot conductance measurement program. Three different slot measurement techniques were evaluated. The selection of the probe comparison measurement technique was selected as the principal experimental method with the impedance measurement technique chosen to measure a few higher conductance slots to be used as reference slots. The impedance of 43 slots in 0.9 x 0.4 inch standard waveguide and of 40 slots in 0.835 x 0.4 inch waveguide was measured. Also, impedance measurements were made of a few slots using image planes to simulate mutual coupling effects. The measured and theoretical conductance, susceptance, and radiation phase data are presented in graphic form as a function of slot displacement for constant slot length, and of slot length for constant slot displacement. It is concluded that the proposed MRF array design approach is a feasible one.

Ratkevich, A. E.↗

Aperture-Coupled Thin-Membrane L-Band Antenna

The upper part of the figure depicts an aperture-coupled L-band antenna comprising patterned metal conductor films supported on two thin polyimide membranes separated by an air gap. In this antenna, power is coupled from a microstrip line on the lower surface of the lower membrane, through a slot in a metal ground plane on the upper surface of the lower membrane, to a radiating metal patch on the upper surface of the upper membrane. The two-membrane configuration of this antenna stands in contrast to a three-membrane configuration heretofore considered as the basis for developing arrays of dual-polarization, wideband microwave antennas that could be thin and could be, variously, incorporated into, or supported on, thin structures, including inflatable structures. By reducing the number of membranes from three to two, the present design simplifies the problems of designing and fabricating such antennas or arrays of such antennas, including the problems of integrating such antennas or arrays with thin-membrane-mounted transmit/ receive modules. In addition, the use of aperture (slot) coupling eliminates the need for rigid coaxial feed pins and associated solder connections on thin membranes, making this antenna more mechanically reliable, relative to antennas that include coaxial feed pins. This antenna is designed for a nominal frequency of 1.26 GHz. The polyimide membranes are 0.05 mm thick and have a relative permittivity of 3.4. The radiating patch is square, 8.89 cm on each side. This radiating patch lies 1.27 cm above the ground plane. The feeding microstrip line is 0.12 mm wide and has a characteristic impedance of 50 . The aperture-coupling slot, etched in the ground plane, is 0.48 mm wide and 79.5 mm long. In order to maximize coupling, the microstrip line is extended beyond the middle of the slot by a length of 36 mm, which corresponds to a transmission- line electrical length of about a quarter wavelength. The other end of the microstrip line is transformed to a 50-Ohm coplanar waveguide line, which is used for connection to a transmit/receive module. Some plated-through vias are added to the outer conductors of the coplanar waveguide to suppress parallel-plate modes. The measured and calculated 10-dB-return-loss bandwidth of the antenna is 100 MHz. By eliminating the radiating patch and the upper membrane that supports it, and performing two other simple modifications, one can convert the two-membrane antenna described above to a paper-thin single-membrane antenna, shown in the lower part of the figure. One modification is to increase the slot length to 104.95 mm; the other is to extend the microstrip to 36.68 mm past the middle of the slot. With these modifications, the slot now becomes a half-wavelength radiator with a nearly omnidirectional radiation pattern. In one potential use, such a paper-thin antenna could be pasted on an automobile window to enable omnidirectional communication.

Huang, John↗

THE LOW-FREQUENCY CHARACTERISTICS OF PSR J0437–4715 OBSERVED WITH THE MURCHISON WIDE-FIELD ARRAY

We report on the detection of the millisecond pulsar PSR J0437–4715 with the Murchison Wide-field Array (MWA) at a frequency of 192 MHz. Our observations show rapid modulations of pulse intensity in time and frequency that arise from diffractive scintillation effects in the interstellar medium (ISM), as well as prominent drifts of intensity maxima in the time-frequency plane that arise from refractive effects. Our analysis suggests that the scattering screen is located at a distance of ∼80-120 pc from the Sun, in disagreement with a recent claim that the screen is closer (∼10 pc). Comparisons with higher frequency data from Parkes reveal a dramatic evolution of the pulse profile with frequency, with the outer conal emission becoming comparable in strength to that from the core and inner conal regions. As well as demonstrating the high time resolution science capabilities currently possible with the MWA, our observations underscore the potential to conduct low-frequency investigations of timing-array millisecond pulsars, which may lead to increased sensitivity in the detection of nanoHertz gravitational waves via the accurate characterization of ISM effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters↗

NanoXCT - A High-Resolution Technique For TSV Characterization

Lab-based Transmission X-ray Microscopy and X-ray Computed Tomography (TXM/XCT) with sub-100 nm resolution are evaluated for their application in process and quality control in microelectronics, particularly for TSV characterization. These are the techniques of choice to localize defects in copper TSVs for 3D IC integration. In contrast to other techniques like Focused Ion Beam cross-sectioning and subsequent Scanning Electron Microscopy imaging, the region of interest, i.e. the TSV, is imaged nondestructively and three dimensionally. For flat samples like thinned wafers, the tilted rotational axis tomography is proposed instead of the limited angle tomography since the better in-plane resolution increases the quality of the resulting tomogram. Yield- and reliability-limiting processes in 3D TSV technology like voids and incomplete filled vias can be made visible for an array of adjacent TSVs during one measurement without affecting the TSV.

36 MATERIALS SCIENCE↗

Strain effects on stability of topological ferroelectric polar configurations in (PbTiO3) n /(SrTiO3) n superlattices

The (PbTiO3)n/(SrTiO3)n (PTO/STO) superlattice system has been shown to exhibit interesting topological phases (e.g., vortices and skyrmions) in addition to normal ferroelectric domain states. Existing studies are mostly focused on the dependence of topological polar distributions and properties of PTO/STO superlattice on its periodicity. Here, we study the strain effect on the topological phase transitions and ferroelectric domain structures employing phase-field simulations. We summarized in an isotropic strain (in-plane misfit strain along the x direction is equal to that along the y direction) periodicity phase diagram displaying the stability regions of different polar topological states, including normal ferroelectric twins, vortices, skyrmions, and mixtures of vortices and twins. We also analyzed the polarization configurations under anisotropic in-plane strains (in-plane misfit strain along the x direction is not equal to that along the y direction) and demonstrated that the strain anisotropy can be used to tune the directions of vortex arrays along either the [100] pc or [010] pc directions or labyrinth vortex arrays. This work offers guidance to manipulating polar structures in the PTO/STO superlattices via strain engineering.

Physics↗

Arecibo pulsar survey using ALFA. III. Precursor survey and population synthesis

The Pulsar Arecibo L-band Feed Array (PALFA) Survey uses the ALFA 7-beam receiver to search both inner and outer Galactic sectors visible from Arecibo (32° ≲ ℓ ≲ 77° and 168° ≲ ℓ ≲ 214°) close to the Galactic plane (|b| ≲ 5°) for pulsars. The PALFA survey is sensitive to sources fainter and more distant than have previously been seen because of Arecibo's unrivaled sensitivity. In this paper we detail a precursor survey of this region with PALFA, which observed a subset of the full region (slightly more restrictive in ℓ and |b| ≲ 1°) and detected 45 pulsars. Detections included 1 known millisecond pulsar and 11 previously unknown, long-period pulsars. In the surveyed part of the sky that overlaps with the Parkes Multibeam Pulsar Survey (36° ≲ ℓ ≲ 50°), PALFA is probing deeper than the Parkes survey, with four discoveries in this region. For both Galactic millisecond and normal pulsar populations, we compare the survey's detections with simulations to model these populations and, in particular, to estimate the number of observable pulsars in the Galaxy. We place 95% confidence intervals of 82,000 to 143,000 on the number of detectable normal pulsars and 9000 to 100,000 on the number of detectable millisecond pulsars in the Galactic disk. These are consistent with previous estimates. Given the most likely population size in each case (107,000 and 15,000 for normal and millisecond pulsars, respectively), we extend survey detection simulations to predict that, when complete, the full PALFA survey should have detected 1000{sub −230}{sup +330} normal pulsars and 30{sub −20}{sup +200} millisecond pulsars. Identical estimation techniques predict that 490{sub −115}{sup +160} normal pulsars and 12{sub −5}{sup +70} millisecond pulsars would be detected by the beginning of 2014; at the time, the PALFA survey had detected 283 normal pulsars and 31 millisecond pulsars, respectively. We attribute the deficiency in normal pulsar detections predominantly to the radio frequency interference environment at Arecibo and perhaps also scintillation—both effects that are currently not accounted for in population simulation models.

79 ASTRONOMY AND ASTROPHYSICS↗

In-beam conversion-electron spectroscopy of {sup 180}Hg

Excited states in {sup 180}Hg were populated using the {sup 147}Sm({sup 36}Ar,3n){sup 180}Hg reaction and studied by in-beam conversion-electron spectroscopy. Conversion electrons emitted at the target position were measured using the Silicon Array for Conversion Electron Detection (SACRED) spectrometer and tagged through the characteristic {alpha} decays of {sup 180}Hg detected in a position-sensitive silicon strip detector located at the focal plane of the gas-filled recoil separator Recoil Ion Transport Unit (RITU). Electron conversion of transitions previously assigned to {sup 180}Hg through in-beam {gamma}-ray spectroscopy studies was identified up to the 10{sup +}{yields}8{sup +} transition and the intensities of the conversion-electron transitions were found to be consistent with the previous multipolarity assignments. Evidence was also found for two highly converted transitions in {sup 180}Hg: a 167 keV transition is interpreted as the transition from the newly identified 2{sub 2}{sup +} state at 601 keV to the 2{sub 1}{sup +} state at 434 keV, while a 420 keV transition is assigned as the E0 decay from the 0{sup +} bandhead of the prolate-deformed configuration to the weakly deformed ground state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-492: Influence of Clipping PTV in Build-Up Region On IMRT Plan Quality and Deliverability

Purpose: To study the influence of clipping PTV from body contour on plan quality and deliverability in build-up region for superficial target. Methods: Five previously treated patients of post-operative carcinoma of parotid were re-planned for IMRT (6MV X-rays, sliding window technique, five fields and 60Gy/30 fractions) using eclipse treatment planning system (TPS) by keeping dose volume constraints and all other parameters constant, only PTV was clipped from body contour by 0mm, 1mm, 2mm and 3mm respectively. Planned fluence was transferred to previously scanned solid water phantom by placing I’matriXX array at 0.5cm depth (2mm slab+3mm inherent). Fluence was delivered by Varian CL2300C/D linac at 99.5cm source to detector distance. Measured fluence was compared with TPS dose plane using 2D gamma evaluation using 3%/3mm DTA criteria. Total MU (monitor unit) required to deliver a plan was also noted. For plan quality, PTV, maximum-dose, minimum-dose, coverage index (CI=PTV volume covered by prescription dose/PTV) and heterogeneity index HI=D5/D95 were analyzed using dose volume histogram (DVH). Results: The Result of gamma function analysis for I’matriXX and TPS were 97.63±1.79%, 97.48±0.99, 98.08±0.89% and 98.01±0.78% at 0.5cm build-up depth for 0, 1, 2 and 3mm PTV clipping, respectively. I’matriXX measured dose was higher compared to TPS. Total MU required for delivering a plan were 552±61, 503±47, 436±24 and 407±22. Maximum-dose to PTV was 6635.80±62.01cGy, 6635.80±40.60cGy, 6608.43±51.07cGy and 6564.20±28.51cGy. Similarly, minimum-dose to PTV was 3306.23±458.56cGy, 3546.57±721.01cGy, 4591.43±298.81cGy and 4861.90±412.40cGy. CI was 0.9347±0.020, 0.9398±0.021, 0.9448±0.022 and 0.9481±0.021. Similarly, HI was 1.089±0.015, 1.084±0.014, 1.078±0.009 and 1.074±0.008 for 0, 1, 2 and 3mm PTV clipping, respectively. Conclusion: Gamma function analysis resulted in almost similar results. However, I’matriXX was overestimating the dose compared to TPS. MU required to deliver a plan decreases with increase in PTV clipping. CI, PTV minimum-dose and plan homogeneity increases with increase in PTV clipping from skin.

60 APPLIED LIFE SCIENCES↗

Multispectral mapper - Imaging spectroscopy as applied to the mapping of earth resources

An instrument concept that uses solid-state array imaging has been developed for a future land observing system. The design concept is responsive to a variety of use needs and provides improved capabilities over the planned Landsat Thematic Mapper. A comparison of the differing approaches to the instrument design was made, resulting in the selection of a concept which uses a spectrograph coupled to a line-array imager to provide simultaneous spatial and spectral resolution. The design provides an inherent solution to the problem of achieving precise registration among the spectral bands. Data processing on the focal plane is used to select the spectral bands and their band widths. Onboard capabilities include radiometric correction, selection of instantaneous field-of-view and swath width, and data compression.

Wellman, J. B.↗