Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Prompt-gamma detection towards absorbed energy monitoring during hadrontherapy

Hadrontherapy is an emerging technique which exploits the fact that a large quantity of the energy of the incident particles is deposited at the end of their flight path. This allows a conformation of the applied dose to the tumor volume and a simultaneous sparing of surrounding healthy tissue. A real-time control of the ion range during the treatment is possible via the detection of prompt secondary radiation (gamma rays or charged particles). Besides a monitoring of the ion range, the knowledge of the total energy absorbed inside the patient is also of importance for an improvement of the treatment quality. It has been shown that the ambient dose in a treatment room is correlated to the monitoring units, i.e. the number of protons of the beam delivery system. The present study consists in applying time-of-flight (TOF) information to identify prompt gamma-rays generated by interactions inside the patient which provides a direct information on the energy imparted. Results from test measurements will be given, which show that events generated in the nozzle and the target phantom can be discriminated. Furthermore, a standalone detection system is being developed which will be read out by a standard PC. The status of the developments for the corresponding electronics will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Continuation of Long-Term Global SO2 Pollution Monitoring from OMI to OMPS

Over the past 20 years, advances in satellite remote sensing of pollution-relevant species have made space-borne observations an increasingly important part of atmospheric chemistry research and air quality management. This progress has been facilitated by advanced UV-vis spectrometers, such as the Ozone Monitoring Instrument (OMI) on board the NASA Earth Observing System (EOS) Aura satellite, and continues with new instruments, such as the Ozone Mapping and Profiler Suite (OMPS) on board the NASA-NOAA Suomi National Polar-orbiting Partnership (SNPP) satellite. In this study, we demonstrate that it is possible, using our state-of-the-art principal component analysis (PCA) retrieval technique, to continue the long-term global SO2 pollution monitoring started by OMI with the current and future OMPS instruments that will fly on the NOAA Joint Polar Satellite System (JPSS) 1, 2, 3, and 4 satellites in addition to SNPP, with a very good consistency of retrievals from these instruments. Since OMI SO2 data have been primarily used for (1) providing regional context on air pollution and long-range transport on a daily basis and (2) providing information on point emission sources on an annual basis after data averaging, we focused on these two aspects in our OMI-OMPS comparisons. Four years of retrievals (2012-2015) have been compared for three regions: eastern China, Mexico, and South Africa. In general, the comparisons show relatively high correlations (r = 0. 79-0.96) of daily regional averaged SO2 mass between the two instruments and near-unity regression slopes (0.76-0.97). The annual averaged SO2 loading differences between OMI and OMPS are small (< 0.03 Dobson unit (DU) over South Africa and up to 0.1 DU over eastern China). We also found a very good correlation (r = 0. 92-0.97) in the spatial distribution of annual averaged SO2 between OMI and OMPS over the three regions during 2012-2015. The emissions from ∼ 400 SO2 sources calculated with the two instruments also show a very good correlation (r = ∼ 0.9) in each year during 2012-2015. OMPS-detected SO2 point source emissions are slightly lower than those from OMI, but OMI-OMPS differences decrease with increasing strength of source. The OMI-OMPS SO2 mass differences on a pixel by pixel (daily) basis in each region can show substantial differences. The two instruments have a spatial correlation coefficient of 0.7 or better on < ∼ 50 % of the days. It is worth noting that consistent SO2 retrievals were achieved without any explicit adjustments to OMI or OMPS radiance data and that the retrieval agreement may be further improved by introducing a more comprehensive Jacobian lookup table than is currently used.

satellite remote sensing of pollution↗

The Impact of Atmospheric InfraRed Sounder (AIRS) Profiles on Short-term Weather Forecasts

The Atmospheric Infrared Sounder (AIRS), together with the Advanced Microwave Sounding Unit (AMSU), represents one of the most advanced spacebased atmospheric sounding systems. The combined AlRS/AMSU system provides radiance measurements used to retrieve temperature profiles with an accuracy of 1 K over 1 km layers under both clear and partly cloudy conditions, while the accuracy of the derived humidity profiles is 15% in 2 km layers. Critical to the successful use of AIRS profiles for weather and climate studies is the use of profile quality indicators and error estimates provided with each profile Aside form monitoring changes in Earth's climate, one of the objectives of AIRS is to provide sounding information of sufficient accuracy such that the assimilation of the new observations, especially in data sparse region, will lead to an improvement in weather forecasts. The purpose of this paper is to describe a procedure to optimally assimilate highresolution AIRS profile data in a regional analysis/forecast model. The paper will focus on the impact of AIRS profiles on a rapidly developing east coast storm and will also discuss preliminary results for a 30-day forecast period, simulating a quasi-operation environment. Temperature and moisture profiles were obtained from the prototype version 5.0 EOS science team retrieval algorithm which includes explicit error information for each profile. The error profile information was used to select the highest quality temperature and moisture data for every profile location and pressure level for assimilation into the ARPS Data Analysis System (ADAS). The AIRS-enhanced analyses were used as initial fields for the Weather Research and Forecast (WRF) system used by the SPORT project for regional weather forecast studies. The ADASWRF system will be run on CONUS domain with an emphasis on the east coast. The preliminary assessment of the impact of the AIRS profiles will focus on quality control issues associated with AIRS, intelligent use of the quality indicators, and forecast verification.

Chou, Shih-Hung↗

High-Sensitivity NO 2 Gas Sensor: Exploiting UV-Enhanced Recovery in a Hexadecafluorinated Iron Phthalocyanine-Reduced Graphene Oxide

Monitoring ultralow nitrogen dioxide (NO 2 ) concentrations is crucial for air quality management and public health. However, the existing NO 2 gas sensors have several defects, like high cost and power consumption, and exhibit poor selectivity. This study addresses these challenges by presenting a novel hexadecafluorinated iron phthalocyanine-reduced graphene oxide (FePcF 16 -rGO) covalent hybrid sensor for NO 2 detection. This innovative approach, which overcomes the limitations of fabrication cost, energy efficiency, and gas selectivity, is a significant step forward in gas sensor technology. The sensor demonstrates exceptional sensitivity toward ultralow NO 2 concentrations (15.14% response for 100 ppb) with a rapid 60 s UV light-induced recovery. Additionally, the sensor exhibits high selectivity for NO 2 , achieving a limit of detection (LOD) of 8.59 ppb. This approach paves the way for developing cost-effective, energy-efficient, and miniature NO 2 monitoring devices for improved environmental monitoring and enhanced safety in workplaces where NO 2 exposure is a concern.

36 MATERIALS SCIENCE↗

Scalable graphene sensor array for real-time toxins monitoring in flowing water

Abstract Risk management for drinking water often requires continuous monitoring of various toxins in flowing water. While they can be readily integrated with existing water infrastructure, two-dimensional (2D) electronic sensors often suffer from device-to-device variations due to the lack of an effective strategy for identifying faulty devices from preselected uniform devices based on electronic properties alone, resulting in sensor inaccuracy and thus slowing down their real-world applications. Here, we report the combination of wet transfer, impedance and noise measurements, and machine learning to facilitate the scalable nanofabrication of graphene-based field-effect transistor (GFET) sensor arrays and the efficient identification of faulty devices. Our sensors were able to perform real-time detection of heavy-metal ions (lead and mercury) and E. coli bacteria simultaneously in flowing tap water. This study offers a reliable quality control protocol to increase the potential of electronic sensors for monitoring pollutants in flowing water.

47 OTHER INSTRUMENTATION↗

Application of MODIS Products to Infer Possible Relationships Between Basin Land Cover and Coastal Waters Turbidity Using the Magdalena River, Colombia, as a Case Study

Basin development and consequent change in basin land cover have been often associated with an increased turbidity in coastal waters because of sediment yield and nutrients loading. The later leads to phytoplankton abundance further exacerbating water turbidity. This subsequently affects biological and physical processes in coastal estuaries by interfering with sun light penetration to coral reefs and sea grass, and even affecting public health. Therefore, consistent estimation of land cover changes and turbidity trend lines is crucial to design environmental and restoration management plans, to predict fate of possible pollutants, and to estimate sedimentary fluxes into the ocean. Ground solely methods to estimate land cover change would be unpractical and traditional methods of monitoring in situ water turbidity can be very expensive and time consuming. Accurate monitoring on the status and trends of basin land cover as well as the water quality of the receiving water bodies are required for analysis of relationships between the two variables. Use of remote sensing (RS) technology provides a great benefit for both fields of study, facilitating monitoring of changes in a timely and cost effective manner and covering wide areas with long term measurements. In this study, the Magdalena River basin and fixed geographical locations in the estuarine waters of its delta are used as a case to study the temporal trend lines of both, land cover change and the reflectance of the water turbidity using satellite technology. Land cover data from a combined product between sensors Terra and Aqua (MCD12Q1) from MODIS will be adapted to the conditions in the Magdalena basin to estimate changes in land cover since year 2000 to 2009. Surface reflectance data from a MODIS, Terra (MOD09GQ), band 1, will be used in lieu of in situ water turbidity for the time period between 2000 and present. Results will be compared with available existing data.

Madrinan, Max Jacobo Moreno↗

Terra and Aqua MODIS Instrument Performance

Since launch, Terra and Aqua MODIS have produced an unprecedentedly large amount of high quality data products and supported a broad range of applications by the remote sensing science community and users worldwide. Constant and dedicated efforts have been made to continue instrument normal operation, to monitor and characterize changes in sensor responses, and to update calibration parameters to maintain the quality of MODIS data products. This paper provides an overview of instrument operation and calibration activities, and performance. On-orbit changes in sensor responses are illustrated. Also discussed are challenging issues, calibration strategies, and future efforts.

Xiong, X.↗

Sensor Networks for Detecting Toxic Releases in Buildings

Sudden releases of a toxic agent indoors can cause immediate and long-term harm to occupants. In order to protect building occupants from such threats, it is necessary to have a robust air monitoring system that can detect, locate, and characterize accidental or deliberate toxic gas releases. However, developing such a system is complicated by several requirements, in particular the need to operate in real-time. This task is further complicated when monitoring sensors are prone to false positive and false negative readings. We report on work towards developing an indoor monitoring system that is robust even in the presence of poor quality sensor data. The algorithm, named BASSET, combines deterministic modeling and Bayesian statistics to join prior knowledge of the contaminant transport in the building with real-time sensor information. We evaluate BASSET across several data sets, which vary in sensor characteristics such as accuracy, response time, and trigger level. Our results suggest that optimal designs are not always intuitive. For example, a network comprised of slower but more accurate sensors may locate the contaminant source more quickly than a network with faster but less accurate sensors.

54 ENVIRONMENTAL SCIENCES↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2015

This report provides a synopsis of ongoing environmental management performance and compliance activities conducted during 2015, meeting the requirements DOE Order 231.1B, Admin Chg 1, Environmental, Safety and Health Reporting, and DOE Order 458.1, Radiation Protection of the Public and the Environment. The report addresses the operations occurring on the PNNL Campus in Richland, Washington, and at the PNNL Marine Sciences Laboratory (MSL) in Sequim, Washington. It describes the location and background for each facility; addresses compliance with all applicable DOE, federal, state, and local regulations and site-specific permits; documents environmental monitoring efforts and their status; presents potential radiation doses to staff and the public in the surrounding areas; and describes DOE-required data quality assurance methods used for data verification.

54 ENVIRONMENTAL SCIENCES↗

In Situ Monitoring of Groundwater Contamination Using the Kalman Filter

This study presents a Kalman filter-based framework to establish a real-time in situ monitoring system for groundwater contamination based on in situ measurable water quality variables, such as specific conductance (SC) and pH. First, this framework uses principal component analysis (PCA) to identify correlations between the contaminant concentrations of interest and in situ measurable variables. It then applies the Kalman filter to estimate contaminant concentrations continuously and in real-time by coupling data-driven concentration-decay models with the previously identified data correlations. We demonstrate our approach with historical groundwater data from the Savannah River Site F-Area: We use SC and pH data to estimate tritium and uranium concentrations over time. Results show that the developed method can estimate these contaminant concentrations based on in situ measurable variables. The estimates remain reliable with less frequent or no direct measurements of the contaminant concentrations, while capturing the dynamics of short- and long-term contaminant concentration changes. In addition, we show that data mining, such as PCA, is useful to understand correlations in groundwater data and to design long-term monitoring systems. As a result, the developed in situ monitoring methodology is expected to improve long-term groundwater monitoring by continuously confirming the contaminant plume's stability and by providing an early warning system for unexpected changes in the plume's migration.

54 ENVIRONMENTAL SCIENCES↗

Mapping of Spacecraft Atmosphere Monitor Signal to Major Constituent Abundances

The Spacecraft Atmosphere Monitor (S.A.M.) follows the JPL’s commitment to introduce and develop next-generation instrumentation concepts for sensing the air quality on manned space flights via continuous sampling, measuring, and reporting in 2s intervals on all gaseous pollutants. The S.A.M. will have two modes of operation: the Major Constituent Analysis (MCA) mode and the Trace Gas Analysis (TGA) mode. The MCA mode will report on molecular analytes such as CH4, H2O, N2, O2, Ar, and CO2 while the TGA mode will acquire minute amounts of volatile organic compounds. Both modes assess the composition of the ambient air with twenty full mass spectra per second giving rise to a substantial amount of data to be processed by a set of small footprint software stacks hosted by an on-board computer. Mass spectra will be accumulated as the number of counts recorded in a given mass-to-charge channel and converted into the absolute abundances of detected species using an efficient algorithm. The decomposition algorithm contains four units: peak identification, mass calibration, background and dead time correction, and an abundance analysis unit. The abundance analysis module identifies target species through their characteristic fragmentation patterns in the presence of molecular isobars, such as CO and N2. For example, in order to identify N2 analyte, the code will simultaneously monitor abundance ratios of the 14, 28 and 29 Th signals and will adapt to any instability caused by a decrease in ambient pressure or changes in humidity. This requirement becomes critical for instruments designed to monitor the near real-time quality of cabin air and promptly provide accurate feedbacks.

Nikolic, D.↗

Preliminary effects of Marcellus shale drilling on Louisiana waterthrush in West Virginia

Preliminary effects of Marcellus shale drilling on Louisiana Waterthrush in West Virginia Page 1 of 1 Doug Becker and James Sheehan, WV Cooperative Fish and Wildlife Research Unit, West Virginia Univ., Morgantown, WV 26506, USA; Petra Bohall Wood, U.S. Geological Survey, WV Cooperative Fish and Wildlife Research Unit, West Virginia Univ., Morgantown, WV 26506, USA; Harry Edenborn, National Energy Technology Laboratory, U.S. Department of Energy, Pittsburgh, PA 15236, USA. Spurred by technological advances and high energy prices, extraction of natural gas from Marcellus shale is increasing in the Appalachian Region. Because little is known about effects on wildlife populations, we studied immediate impacts of oil and gas CO&G) extraction on demographics and relative abundance of Louisiana Waterthrush'CLOWA), a riparian obligate species, to establish a baseline for potential future changes. Annually in 2008-2010, we conducted point counts, monitored Mayfield nesting success, spotted-mapped territories, and measured habitat quality using the EPA Rapid Bioassessment protocol for high gradient streams and a LOWA Habitat Suitability Index CHSI) on a 4,100 ha study area in northern West Virginia. On 11 streams, the stream length affected by O&G activities was 0-58%. Relative abundance, territory denSity, and nest success varied annually but were not significantly different across years. Success did not differ between impacted and unimpacted nests, but territory density had minimal correlation with percent of stream impacted by O&G activities. Impacted nests had lower HSI values in 2010 and lower EPA indices in 2009. High site fidelity could mask the immediate impacts of habitat disturbance from drilling as we measured return rates of 57%. All returning individuals were on the same stream they were banded and 88% were within 250 m of their territory from the previous year. We also observed a spatial shift in LOWA territories, perhaps in response to drilling activities. Preliminary results identified few differences at low habitat disturbance levels but highlight the need for continued monitoring with increasing disturbance. file:

01 COAL, LIGNITE, AND PEAT↗

A proven approach for more effective software development and maintenance

Modern space flight mission operations and associated ground data systems are increasingly dependent upon reliable, quality software. Critical functions such as command load preparation, health and status monitoring, communications link scheduling and conflict resolution, and transparent gateway protocol conversion are routinely performed by software. Given budget constraints and the ever increasing capabilities of processor technology, the next generation of control centers and data systems will be even more dependent upon software across all aspects of performance. A key challenge now is to implement improved engineering, management, and assurance processes for the development and maintenance of that software; processes that cost less, yield higher quality products, and that self-correct for continual improvement evolution. The NASA Goddard Space Flight Center has a unique experience base that can be readily tapped to help solve the software challenge. Over the past eighteen years, the Software Engineering Laboratory within the code 500 Flight Dynamics Division has evolved a software development and maintenance methodology that accommodates the unique characteristics of an organization while optimizing and continually improving the organization's software capabilities. This methodology relies upon measurement, analysis, and feedback much analogous to that of control loop systems. It is an approach with a time-tested track record proven through repeated applications across a broad range of operational software development and maintenance projects. This paper describes the software improvement methodology employed by the Software Engineering Laboratory, and how it has been exploited within the Flight Dynamics Division with GSFC Code 500. Examples of specific improvement in the software itself and its processes are presented to illustrate the effectiveness of the methodology. Finally, the initial findings are given when this methodology was applied across the mission operations and ground data systems software domains throughout Code 500.

Pajerski, Rose↗

Development of a novel ArcCHECK{sup Trade-Mark-Sign} insert for routine quality assurance of VMAT delivery including dose calculation with inhomogeneities

Purpose: To design a versatile, nonhomogeneous insert for the dose verification phantom ArcCHECK{sup Trade-Mark-Sign} (Sun Nuclear Corp., FL) and to demonstrate its usefulness for the verification of dose distributions in inhomogeneous media. As an example, we demonstrate it can be used clinically for routine quality assurance of two volumetric modulated arc therapy (VMAT) systems for lung stereotactic body radiation therapy (SBRT): SmartArc{sup Registered-Sign} (Pinnacle{sup 3}, Philips Radiation Oncology Systems, Fitchburg, WI) and RapidArc{sup Registered-Sign} (Eclipse{sup Trade-Mark-Sign }, Varian Medical Systems, Palo Alto, CA). Methods: The cylindrical detector array ArcCHECK{sup Trade-Mark-Sign} has a retractable homogeneous acrylic insert. In this work, we designed and manufactured a customized heterogeneous insert with densities that simulate soft tissue, lung, bone, and air. The insert offers several possible heterogeneity configurations and multiple locations for point dose measurements. SmartArc{sup Registered-Sign} and RapidArc{sup Registered-Sign} plans for lung SBRT were generated and copied to ArcCHECK{sup Trade-Mark-Sign} for each inhomogeneity configuration. Dose delivery was done on a Varian 2100 ix linac. The evaluation of dose distributions was based on gamma analysis of the diode measurements and point doses measurements at different positions near the inhomogeneities. Results: The insert was successfully manufactured and tested with different measurements of VMAT plans. Dose distributions measured with the homogeneous insert showed gamma passing rates similar to our clinical results ({approx}99%) for both treatment-planning systems. Using nonhomogeneous inserts decreased the passing rates by up to 3.6% in the examples studied. Overall, SmartArc{sup Registered-Sign} plans showed better gamma passing rates for nonhomogeneous measurements. The discrepancy between calculated and measured point doses was increased up to 6.5% for the nonhomogeneous insert depending on the inhomogeneity configuration and measurement location. SmartArc{sup Registered-Sign} and RapidArc{sup Registered-Sign} plans had similar plan quality but RapidArc{sup Registered-Sign} plans had significantly higher monitor units (up to 70%). Conclusions: A versatile, nonhomogeneous insert was developed for ArcCHECK{sup Trade-Mark-Sign} for an easy and quick evaluation of dose calculations with nonhomogeneous media and for comparison of different treatment planning systems. The device was tested for SmartArc{sup Registered-Sign} and RapidArc{sup Registered-Sign} plans for lung SBRT, showing the uncertainties of dose calculations with inhomogeneities. The new insert combines the convenience of the ArcCHECK{sup Trade-Mark-Sign} and the possibility of assessing dose distributions in inhomogeneous media.

60 APPLIED LIFE SCIENCES↗

Ambient Monitoring for Sinclair and Dyes Inlets, Puget Sound, Washington: Chemical Analyses for 2010 Regional Mussel Watch (AMB02)

The Puget Sound Naval Shipyard & Intermediate Maintenance Facility (PSNS&IMF) and Naval Base Kitsap-Bremerton (Shipyard) located in Bremerton, WA are committed to a culture of continuous process improvement for all aspects of Shipyard operations, including reducing the releases of hazardous materials and waste in discharges from the Shipyard. Under the Project ENVVEST Final Project Agreement, a cooperative project among PSNS&IMF, the Environmental Protection Agency (EPA), and the Washington State Department of Ecology (Ecology), and local stakeholders (US Navy, EPA and Ecology 2002) has been helping to improve the environmental quality of the Sinclair and Dyes Inlet Watershed (ENVVEST 2006). An ambient monitoring program for sediment, water, and indigenous mussels began in 2009 to assess the status and trend of ecological resources, assess the effectiveness of cleanup and pollution control measures, and determine if discharges from all sources are protective of beneficial uses including aquatic life. This document presents the 2010 chemical residue data and stable isotopes of carbon (δ13C) and nitrogen (δ15N) for the regional mussel watch stations located in Sinclair Inlet, Dyes Inlet, Port Orchard Passage, Rich Passage, Agate Passage, Liberty Bay, and Keyport Lagoon. Indigenous bivalves were collected from a small boat and/or from along the shoreline, measured, composited, and analyzed for a suite of trace metals and organic contaminants. The trace metals included silver, arsenic, cadmium, chromium, copper, mercury, nickel, lead, and zinc. The organic contaminants included the list of NOAA Status and Trends 20 polychlorinated biphenyls (PCB) congeners and suite of parent and methylated polycyclic aromatic hydrocarbons (PAHs). These chemical residue data provide the first year of the biota ambient monitoring.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time process monitoring for direct ink write additive manufacturing

Direct ink write (DIW) printing of reactive resins presents a unique challenge due to the time-dependent nature of the rheological and chemical properties of the ink. As a result, careful print optimization or process control is important to obtain consistent, high quality prints. The present invention uses a flow-through characterization cell for in situ chemical monitoring of a resin ink during DIW printing. Additionally, in-line extrusion force monitoring can be combined with off-line post inspection using machine vision. By combining in-line spectroscopy and force monitoring, it is possible to follow reaction kinetics (for example, curing of a reactive resin) and viscosity changes during printing, which can be used for a closed-loop process control. Additionally, the capability of machine vision to automatically identify and quantify print artifacts can be incorporated on the printing line to enable real-time, AI-assisted quality control of the printed products. Together, these techniques can form the building blocks of an optimized process control strategy when complex reactive ink must be used to produce printed hardware.

Cook, Adam W.↗

High-Throughput Uniformity and Defect Monitoring in Low-Temperature Electrolysis Porous Transport Layers Using X-Ray Radiography

Effective quality control (QC) for manufacturing proton exchange membrane water electrolysis (PEMWE) components is critical to enabling widespread adoption of the technology for hydrogen generation. This study investigates X-ray radiography as a novel, high-throughput, potentially in-line QC technique for detecting defects and assessing material property distributions in titanium-based porous transport layers (PTLs) which constitute a crucial component of low temperature PEMWE stacks. We obtain radiographs of a set of fifteen PTLs and model their absorbance of the broadband radiation as a second-order polynomial to account for the non-monoenergetic radiation source used in this study. The resulting model serves as a basis for predicting the areal density and porosity distributions of the PTLs. We find radiography successful in detecting multiple instances of defects, including holes/depressions, cracks, and excess material on the surface or in the pores of the material, demonstrating its potential as a robust in-line QC tool for PTL manufacturing.

08 HYDROGEN↗

2014 Annual Site Environmental Report for Sandia National Laboratories, Tonopah Test Range, Nevada, and Kauai Test Facility, Hawaii

Sandia National Laboratories (SNL) is a multiprogram laboratory managed and operated by Sandia Corporation (Sandia), a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy’s National Nuclear Security Administration (DOE/NNSA) under contract DE-AC04-94AL85000. The DOE/NNSA Sandia Field Office administers the contract and oversees contractor operations at the SNL, Tonopah Test Range (SNL/TTR) in Nevada and the SNL, Kauai Test Facility (SNL/KTF) in Hawaii. Sandia manages and conducts operations at SNL/TTR in support of the DOE/NNSA’s Weapons Ordnance Program and has operated the site since 1957. Navarro Research and Engineering subcontracts with Sandia to administer most of the environmental programs at SNL/TTR. The DOE/NNSA/Nevada Field Office retains responsibility for cleanup and management of SNL/TTR Environmental Restoration sites. Sandia operates SNL/KTF as a rocket preparation launching and tracking facility. This Annual Site Environmental Report summarizes data and the compliance status of Sandia’s sustainability, environmental protection, and monitoring programs at SNL/TTR and SNL/KTF during calendar year 2014. Major environmental programs include air quality, water quality, groundwater protection, terrestrial surveillance, waste management, pollution prevention, environmental restoration cleanup activities, and implementation of the National Environmental Policy Act. Sandia is responsible only for those environmental program activities related to its operations. Environmental monitoring and surveillance programs are required by DOE O 231.1B, Change 1, Environment, Safety, and Health Reporting .

54 ENVIRONMENTAL SCIENCES↗