Environment-based selection effects of Planck clusters

We investigate whether the large-scale structure environment of galaxy clusters imprints a selection bias on Sunyaev–Zel'dovich (SZ) catalogues. Such a selection effect might be caused by line of sight (LoS) structures that add to the SZ signal or contain point sources that disturb the signal extraction in the SZ survey. We use the Planck PSZ1 union catalogue in the Sloan Digital Sky Survey (SDSS) region as our sample of SZ-selected clusters. We calculate the angular two-point correlation function (2pcf) for physically correlated, foreground and background structure in the RedMaPPer SDSS DR8 catalogue with respect to each cluster. We compare our results with an optically selected comparison cluster sample and with theoretical predictions. In contrast to the hypothesis of no environment-based selection, we find a mean 2pcf for background structures of -0.049 on scales of ≲40 arcmin, significantly non-zero at ~4σ, which means that Planck clusters are more likely to be detected in regions of low background density. We hypothesize this effect arises either from background estimation in the SZ survey or from radio sources in the background. We estimate the defect in SZ signal caused by this effect to be negligibly small, of the order of ~10 -4 of the signal of a typical Planck detection. Analogously, there are no implications on X-ray mass measurements. However, the environmental dependence has important consequences for weak lensing follow up of Planck galaxy clusters: we predict that projection effects account for half of the mass contained within a 15 arcmin radius of Planck galaxy clusters. We did not detect a background underdensity of CMASS LRGs, which also leaves a spatially varying redshift dependence of the Planck SZ selection function as a possible cause for our findings.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Platform for the Benchtop Study of Complex Radiological Environments that Affect Fallout Formation: DHS Feasbility Study (Final Report)

Fallout analysis is a crucial field of study as it provides insight into the structural interactions that occur between radiological components and their surroundings following a nuclear event. Due to the complexity of actual fallout samples, setups like the plasma flow reactor (PFR) at LLNL have been developed to synthesize fallout in a controlled environment. While the PFR allows for control of parameters such as initial temperature, cooling rate, and concentration of radiological species, controlling the concentration of water has remained a challenge as samples are introduced into the setup via aqueous solution. To that end, our goal with this project was to develop methodologies to (1) monitor and (2) control the presence of water in the PFR. We found that a commercially available FTIR and MCT detector was sufficient to monitor the presence of both condensed and vapor-phase water, while a desolvating nebulizer could be used to control the amount of water injected into the system. In total, the results of this feasibility study have expanded the ability of the flow reactor to investigate key sensitivities that influence fallout formation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Charging and discharging characteristics of dielectric materials exposed to low- and mid-energy electrons

Charging and discharging characteristics of dielectric samples exposed to 1-25 keV and 25-100 keV electrons in a laboratory environment are reported. The materials examined comprised OSR, Mylar, Kapton, perforated Kapton, and Alphaquartz, serving as models for materials employed on spacecraft in geosynchronous orbit. The tests were performed in a vacuum chamber with electron guns whose beams were rastered over the entire surface of the planar samples. The specimens were examined in low-impedance-grounded, high-impedance-grounded, and isolated configurations. The worst-case and average peak discharge currents were observed to be independent of the incident electron energy, the time-dependent changes in the worst case discharge peak current were independent of the energy, and predischarge surface potentials are negligibly dependent on incident monoenergetic electrons.

Coakley, P.↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗

Comparison of PFASs contamination in the freshwater and terrestrial environments by analysis of eggs from osprey (Pandion haliaetus), tawny owl (Strix aluco), and common kestrel (Falco tinnunculus)

The level of PFAS (per- and polyfluorinated alkyl substances) contamination in freshwater and terrestrial Swedish environments in 2013/2014 was assessed by analyzing a range of perfluorinated alkyl acids, fluorotelomer acids, sulfonamides, sulfonamidoethanols and polyfluoralkyl phosphate diesters (diPAPs) in predator bird eggs. Stable isotopes ({sup 13}C and {sup 15}N) were analyzed to elucidate the dietary source. The tawny owl (Strix aluco, n=10) and common kestrel (Falco tinnunculus, n=40), two terrestrial species, and the osprey (Pandion haliaetus, n=30), a freshwater specie were included. In addition, a temporal trend (1997–2001, 2008–2009, 2013) in osprey was studied as well. The PFAS profile was dominated by perfluorooctane sulfonic acid (PFOS) in eggs from osprey and tawny owl, while for common kestrel perfluorinated carboxylic acids (∑PFCA) exceeded the level of PFOS. PFOS concentration in osprey eggs remained at the same level between 1997 and 2001 and 2013. For the long-chained PFCAs, there were a significant increase in concentrations in osprey eggs between 1997 and 2001 and 2008–2009. The levels of PFOS and PFCAs were about 10 and five times higher, respectively, in osprey compared to tawny owl and common kestrel. Evidence of direct exposure from PFCA precursor compounds to birds in both freshwater and terrestrial environment was observed. Low levels of diPAPs were detected in a few samples of osprey (<0.02–2.4 ng/g) and common kestrel (<0.02–0.16 ng/g) eggs, and 6:2 FTSA was detected in a majority of the osprey eggs (<6.3–52 ng/g). One saturated telomer acid (7:3 FTCA), which is a transformation marker from precursor exposure, was detected in all species (<0.24–2.7 ng/g). The {sup 15}N data showed higher levels in osprey eggs compared to tawny owl and common kestrel, indicating that they feed on a 2–3 times higher trophic level. We conclude that ospreys are continuously exposed to PFAS at levels where adverse toxic effects have been observed in birds. - Highlights: • Levels in the freshwater environment exceeded those of the terrestrial environment. • Birds in both freshwater and terrestrial environment are exposed to PFCA precursors. • No significant change of PFOS level in osprey eggs between 1997 and 2001 and 2013. • PFAS levels pose a risk to birds in the freshwater environment.

54 ENVIRONMENTAL SCIENCES↗

Argon Milling of Bulk and Post-FIB Specimens for Multi-Length Scale Analyses by EBSD, TEM, and APT under Controlled Environments

Correlative investigations involve structural characterization by transmission electron microscopy (TEM) combined with compositional analysis by atom probe tomography (APT) using the same specimen. A critical component of successful correlative analyses is specimen preparation; probing individual atoms requires a surface and subsurface with minimal defects, beginning with the bulk material through to the prepared specimen for TEM or APT analysis. Our previous work showed that low-energy concentrated ion beam Ar ion milling improves TEM [1] and APT [2,3] specimen quality by removing surface oxides and Ga damage caused by focused ion beam (FIB) preparation. Further enhancement in specimen quality of APT specimens is achieved in the established workflow under controlled environments, as shown in [4]. In this work, we present specimen preparation using Ar ion milling techniques not only for the APT specimen, but also the bulk sample for subsequent multi-length scale analyses by electron backscatter diffraction (EBSD), TEM, and APT under controlled environments. The removal of surface damage and oxidation, which is crucial for probing atomic layer specimens by broad and concentrated Ar ion beam milling techniques under controlled environments, is highlighted.

36 MATERIALS SCIENCE↗

Graphite Formation in Cast Iron

In the first phase of the project it was proven that by changing the ratio between the thermal gradient and the growth rate for commercial cast iron samples solidifying in a Bridgman type furnace, it is possible to produce all types of graphite structures, from flake to spheroidal, and all types of matrices, from ferritic to white at a certain given level of cerium. KC-135 flight experiments have shown that in a low-gravity environment, no flotation occurs even in spheroidal graphite cast irons with carbon equivalent as high as 5%, while extensive graphite flotation occurred in both flake and spheroidal graphite cast irons, in high carbon samples solidified in a high gravity environment. This opens the way for production of iron-carbon composite materials, with high carbon content (e.g., 10%) in a low gravity environment. By using KC-135 flights, the influence of some basic elements on the solidification of cast iron will be studied. The mechanism of flake to spheroidal graphite transition will be studied, by using quenching experiments at both low and one gravity for different G/R ratios.

Stefanescu, D. M.↗

Dibenzo-p-dioxins in the environment from ceramics and pottery produced from ball clay mined in the United States

Processed ball clay samples used in the production of ceramics and samples of the ceramic products were collected and analyzed for the presence and concentration of the 2,3,7,8-Cl substituted polychlorinated dibenzo-p-dioxins and -furans (PCDDs/PCDFs). The processed ball clay had average PCDD concentrations of 3.2 ng/g toxic equivalents, a congener profile, and isomer distribution consistent with those found previously in raw ball clay. The PCDF concentrations were below the average limit of detection (LOD) of 0.5 pg/g. The final fired ceramic products were found to be free of PCDDs/PCDFs at the LODs. A consideration of the conditions involved in the firing process suggests that the PCDDs, if not destroyed, may be released to the atmosphere and could represent an as yet unidentified source of dioxins to the environment. In addition, the PCDDs in clay dust generated during manufacturing operations may represent a potential occupational exposure.

Aluminum Silicates/chemistry↗

Effects of urban debris material on the extraction chromatographic separation of strontium: Part II: cement and concrete

The majority of radiochemical separation schemes available have been developed for environmental samples that are not necessarily representative of those found in an urban environment. However, it is much more likely that an incident involving a radiation dispersal device (RDD) would occur in an urban or metropolitan area. It is unclear if the currently available separation schemes would be effective in such an event. It is therefore important to determine if the current schemes would be adequate, or to find efficient and accurate ways to separate radiological material from urban debris. One important radiological material that could be used in an RDD is 90 Sr. Part I of this work investigated the effects steel had on strontium separations, while this work investigates cement and concrete. This research demonstrates that the individual elements present in a cement and concrete sample matrix can give rise to significant interferences with extraction chromatographic separations. In conclusion, solutions of the constituents mixed in representative ratios; however, show fewer problems

36 MATERIALS SCIENCE↗

Engineering experimental program on the effects of near-space radiation on lithium doped solar cells

The results of an experimental evaluation of the real-time degradation characteristics of lithium-diffused silicon solar cells are reported. A strontium-90 radioisotope was used for simulation of a typical earth-orbital electron environment. The experiment was performed in an ion pump vacuum chamber with samples maintained at -50, +20, +50, and +80 C. Samples were illuminated during the 6-month exposure run with solar cell 1-5 characteristics measured periodically in situ. This 6-month exposure corresponded to a 1 MeV equivalent fluence of approximately 10 to the 14th power electrons/sq cm. Several types of lithium cells were irradiatied and compared directly with conventional N/P cells. The best lithium cells compared favorably with N/P cells, particularly at the higher test temperatures. With a slight improvement of initial performance characteristics, lithium cells appear feasible for 5 to 10 year missions at synchronous altitude. Based on the reported results and those of other irradiation experiments, lithium cells would appear to be superior to N/P cells in proton-dominated earth-orbital environments. Another important conclusion of the effort was that illuminated/loaded cells degrade more rapidly than do dark/unloaded cells. The irradiation experiment provided data of high quality with a high degree of confidence because of the experimental and statistical analysis techniques utilized.

Source record↗

Probing Pore Size and Connectivity in Porous Silicas Using 13C MAS NMR Spectroscopy of Supercritical Methane

Measuring the pore size and pore-size distributions and exploring the fluid-exchange dynamics between different types of pores in porous materials remains a significant experimental challenge but is critical to understanding catalysis, chromatography, nutrient cycling, and a whole range of geochemical phenomena, including shale gas and tight gas extraction. Here, we present the results of 1D 13 C NMR and 2D exchange spectroscopy (EXSY) NMR investigations of a porous silica using supercritical methane (scCH 4 ) as a direct probe of pore size and fluid exchange between pore types. The results show that the 13 C chemical shift of scCH 4 adsorbed in nanometer-scale silica pores becomes more negative with increasing pore diameter, in agreement with trends reported for gas hydrates, zeolites, MOFs, and clays and other microporous (<10 nm pores) geochemical materials. These 13 C chemical shifts follow a natural log–linear trend with pore size in the vacuum-dried porous silicas studied here, allowing one to predict pore size based on the 13 C chemical shift in dry silica nanopores. The EXSY and 1D 13 C NMR results both show that CH 4 exchanges between pore and bulk fluid environments over rate scales from 0.01 to 1 kHz in vacuum-dried samples and that exchange dynamics must be considered when interpreting 13 C NMR of pore-adsorbed CH 4 . Introducing H 2 O to the system causes the 13 C chemical shift to become more negative with increasing H 2 O content as a result of H 2 O preferentially filling small pores, forcing CH 4 to occupy larger pores that are better connected to the bulk environment. Likewise, the 1D 13 C data show a decreased distribution of exchange rates between pore-adsorbed and bulk CH 4 in the presence of H 2 O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Where do the fish go in winter? A year of observing seasonal changes in Sequim Bay’s nearshore fish community

The use of environmental DNA (eDNA) sampling has been proposed as a complementary method to monitor fish species in marine environments. eDNA offers a non-invasive, cost-effective, and scalable way to detect aquatic species. It is appealing in environments where traditional methods are limited by access or visibility, especially in complex or sensitive habitats such as tidal channels and other marine energy sites. Before eDNA can be fully relied upon, we must verify its accuracy against established methods, like underwater photography. In this study, we collected eDNA samples and concurrently deployed a 360-degree camera near the floating dock of PNNL-Sequim in the tidal channel of Sequim Bay once a month for twelve consecutive months. During deployments, the camera remained on the seafloor for several hours overlapping slack tide and captured time-lapse photographs at ten second intervals. Counts and identifications of fish species observed in the images were used to calculate monthly Shannon diversity and Pielou evenness indices. These values were compared across the months using a Kruskal-Wallis test paired with a Conover-Iman post-hoc test. Cliff’s Delta was also calculated to quantify the effect size of the monthly differences. No fish were observed from December through April, likely due to seasonal behavior changes within the local fish community. Fish returned to the shoreline in May, with the greatest diversity and evenness recorded in September. These findings reveal substantial seasonal variation in nearshore fish communities. Many monthly comparisons were found to contain statistically significant differences within the diversity and evenness, and even more were found to have large effect sizes, signifying large ecological changes throughout the seasons. The absence of fish observed during the winter months is a key outcome of this survey that will hopefully be reflected in the eDNA results still to come, which would help validate the eDNA approach.

59 BASIC BIOLOGICAL SCIENCES↗

The Athena Mars Rover Science Payload

The Mars Surveyor missions that will be launched in April of 2001 will include a highly capable rover that is a successor to the Mars Pathfinder mission's Sojourner rover. The design goals for this rover are a total traverse distance of at least 10 km and a total lifetime of at least one Earth year. The rover's job will be to explore a site in Mars' ancient terrain, searching for materials likely to preserve a record of ancient martian water, climate, and possibly biology. The rover will collect rock and soil samples, and will store them for return to Earth by a subsequent Mars Surveyor mission in 2005. The Athena Mars rover science payload is the suite of scientific instruments and sample collection tools that will be used to perform this job. The specific science objectives that NASA has identified for the '01 rover payload are to: (1) Provide color stereo imaging of martian surface environments, and remotely-sensed point discrimination of mineralogical composition. (2) Determine the elemental and mineralogical composition of martian surface materials. (3) Determine the fine-scale textural properties of these materials. (4) Collect and store samples. The Athena payload has been designed to meet these objectives. The focus of the design is on field operations: making sure the rover can locate, characterize, and collect scientifically important samples in a dusty, dirty, real-world environment. The topography, morphology, and mineralogy of the scene around the rover will be revealed by Pancam/Mini-TES, an integrated imager and IR spectrometer. Pancam views the surface around the rover in stereo and color. It uses two high-resolution cameras that are identical in most respects to the rover's navigation cameras. The detectors are low-power, low-mass active pixel sensors with on-chip 12-bit analog-to-digital conversion. Filters provide 8-12 color spectral bandpasses over the spectral region from 0.4 to 1.1 micron Narrow-angle optics provide an angular resolution of 0.28 mrad/pixel, nearly a factor of four higher than that of the Mars Pathfinder and Mars Surveyor '98 cameras. Image compression will be performed using a wavelet compression algorithm. The Mini-Thermal Emission Spectrometer (Mini-TES) is a point spectrometer operating in -the thermal IR. It produces high spectral resolution (5 /cm) image cubes with a wavelength range of 5-40 gm, a nominal signal/noise ratio of 500:1, and a maximum angular resolution of 7 mrad (7 cm at a distance of 10 in). The wavelength region over which it operates samples the diagnostic fundamental absorption features of rockforming minerals, and also provides some capability to see through dust coatings that could tend to obscure spectral features. The mineralogical information that Mini-TES provides will be used to select from a distance the rocks and soils that will be investigated in more detail and ultimately sampled. Mini-TES is derived from the MO/MGS TES instrument, but is significantly smaller and simpler. The instrument uses an 8-cm Cassegrain telescope, a Michelson interferometer, and uncooled pyroelectric detectors. Along with its mineralogical capabilities, Mini-TES can provide information on the thermophysical properties of rocks and soils. Viewing upward, it can also provide temperature profiles through the martian atmospheric boundary layer. Elemental and Mineralogical Composition: Once promising samples have been identified from a distance using Pancam/Mini-TES, they will be studied in detail using up to three compositional sensors that can be placed directly against them by an Instrument Arm. The two compositional sensors, presently on the payload are an Alpha-Proton-X-Ray Spectrometer (APXS), and a Mossbauer Spectrometer. The APXS is derived closely from the instrument that flew on Mars Pathfinder. Radioactive alpha sources and three detection modes (alpha, proton, and x-ray) provide elemental abundances of rocks and soils to complement and constrain mineralogical data. The Athena APXS will have a revised mechanical design that will cut down significantly on backscattering of alpha particles from martian atmospheric carbon. It will also include a target of known elemental composition that will be used for calibration purposes. The Athena Mossbauer Spectrometer is a diagnostic instrument for the mineralogy and oxidation state of Fe-bearing phases, which are particularly important on Mars. The instrument measures the resonant absorption of gamma rays produced by a Co-57 source to determine splitting of nuclear energy levels in Fe atoms that is related to the electronic environment surrounding them. It has been under development for space flight for many years at the Technical University of Darmstadt. The Mossbauer Spectrometer (and the other arm instruments) will be able to view a small permanent magnet array that will attract magnetic particles in the martian soil. The payload may also include a Raman Spectrometer. If included, the Raman Spectrometer will provide precise identification of major and minor mineral phases. It requires no sample preparation, and is also sensitive to organics. Fine-Scale Texture: The Instrument Arm a also carries a Microscopic Imager that will obtain high-resolution monochromatic images of the same materials for which compositional data will be obtained. Its spatial resolution is 20 micron/pixel over a 1 cm depth of field, and 40 micron/pixel over a 1-cm depth of field. Like Pancam, it uses the same active pixel sensor detectors and electronics as the rover's navigation cameras. The Instrument Arm is a three degree-of-freedom arm that uses designs and components from the Mars Pathfinder and Mars Surveyor '98 projects. Its primary function is instrument positioning. Along with the instruments noted above, it also carries a brush that can be used to remove dust and other loose coatings from rocks. Sample Collection and Storage: Martian rock and soil samples will be collected using a low-power rotary coring drill called the Mini-Corer. An important characteristic of this device is that it can obtain intact samples of rock from up to 5 cm within strong boulders and bedrock, Nominal core dimensions are 8xl7 mm. The Mini-Corer drills a core to the commanded depth in a rock, shears it off, retains it, and extracts it. It can also acquire samples of loose soil, using soil sample cups that are pressed downward into loose material. The Mini-Corer can drill at angles from vertical to 45' off vertical. It has six interchangeable bits for long life. Mechanical damage to the sample during drilling is minimal, and heating is negligible. After acquisition, the sample may be viewed by the arm instruments, and/or placed in one of 104 compartments in the Sample Container. A subset of the acquired samples may be replaced with other samples obtained later if desired. The Sample Container has no moving parts, and is mounted external to the rover for easy removal by the Mars Surveyor 2005 flight system. Operation of the rover will make extensive use of automated onboard navigation and hazard avoidance capabilities. Otherwise, use of onboard autonomy is minimal. Data downlink capability is about 40 Mbit/sol, and the use of the Mars Surveyor '01 orbiter for data relay imposes a limit of at most two command cycles per sol. Because of the significant amount of time available between command cycles, all payload elements will be operated sequentially, rather than in parallel.; this approach also significantly simplifies operations and minimizes peak power usage. The landing site for the '01 rover has not been selected yet. Site selection will make as full use as possible of Mars Global Surveyor data, and will involve substantial input from the broad Mars science community. Summary: The following table describes the mass, power, providers, and key scientific objectives of all the major elements of the Athena payload. Additional Athena payload information may be found at: http://astrosun.tn.cornell.edu/athena/index.html. Additional information contained in the original.

Squyes, S. W.↗

Accelerated Stress Testing on Multichannel Drivers—Updated Test Results

This report is the second in a series of studies about accelerated stress testing (AST) of drivers used for SSL luminaires. Two-stage drivers intended for use in downlights, troffers and street lights were selected to undergo exposure to an AST environment consisting of 75°C and 75% relative humidity (7575). The 7575 AST environment was chosen for this study because a previous study demonstrated that 38% of a sample population of 6-inch downlights failed in less than 2,500 hours in these conditions. A mixture of single-channel (i.e., one output current channel designed for use with one LED primary) and multichannel (i.e., separate output current channels designed for use with multiple for LED primaries) two-stage drivers were exposed to the 7575 environment. This report provides updated AST test results for only the multichannel driver products. The multichannel driver population consisted of three products (with two-stage architecture) and a total of five samples. In addition to AST results, the product life distribution (Weibull analysis) of two-stage driver Hammer Test samples is reported.

42 ENGINEERING↗

On the Limits of EM Based Detection of Control Logic Injection Attacks In Noisy Environments

The difficulty in applying traditional security mechanisms in Industrial Control System (ICS) environments makes a large portion of these mission-critical assets vulnerable to cyber attacks. Therefore, there is a dire need for the development of novel security mechanisms specifically designed to protect such critical systems. Recently a lot of attention has been given to mechanisms that exploit the EM emanations of devices for defense purposes. Such practices may lead to the development of robust external and non-intrusive anomaly detection systems. Nevertheless, the majority of current work in the area neglects to consider the implications of real-life environments, particularly environmental noise. In this work, we explore the limits of EM-based anomaly detection towards identifying injection attacks in control logic software in noisy environments. Our study conducted upon both synthetically generated and real signals identified that indeed environmental noise might significantly degrade the accuracy of the anomaly detection process. Experiments done upon synthetic data indicated that assuming that signals are captured with high sampling rates, even minor code injections can be detected with above-90% accuracy in noisy environments where SNR is up to -2dB. This is true even if naive detection methods are considered. Moreover, experiments done using a real-life testbed attest that even single-instruction injections can be detected with near-perfect accuracy in relatively clean environments. Finally, noise-elimination techniques can drastically improve the reliability of the detection mechanism even in noisy environments.

97 MATHEMATICS AND COMPUTING↗

Optical Fier Based System for Multiple Thermophysical Properties for Glove Box, Hot Cell and In-Pile Application

Thermal diffusivity of materials is of interest in nuclear applications at temperatures in excess of 2000°C. Commercial laser flash apparatus (LFA) that heats samples with a furnace typically do not reach these elevated temperatures nor are they easily adapted to a glove-box or hot cell environment. In this research, we performed work on an experimental technique using single laser surface heating, i.e. heating the disk sample only at its front surface with the continuous wave (CW) laser, to allow measurement of thermal diffusivity at very high temperatures within a small chamber. Thermal diffusivity is measured using a separate pulsed laser on the front side and IR detector on the rear side. The new way of heating provides easy operation in comparison to other heating methods. The measurement of sample reference temperature is needed for the measured thermal diffusivity. A theoretical model was developed to describe transient heat transfer across the sample due to the laser pulse, starting from the steady state temperature of the sample heated by the CW laser. The experimental setup was established with a 500W CW laser and maximum 50 Joule pulse laser irradiated at the front surface of the sample. The induced temperature rise at the rear surface, along with the steady-state temperature at the front surface, was recorded for the determination of thermal diffusivity and the sample temperature. Three samples were tested in vacuum over a wide temperature range of 500°C to 2100°C, including graphite, Inconel 600 and tungsten. The latter two samples were coated with sprayed graphite on their front surfaces in order to achieve surface absorption/emission needs, i.e. high absorptivity of the front surface against relatively low emissivity of the rear surface. Thermal diffusivity of graphite determined by our system are within a 5% difference of the commercial LFA data at temperatures below 1300°C and agree well with its trend at higher temperatures. Good agreement would also exist for Inconel 600 and tungsten. Despite large uncertainty of measuringthe sample temperature, the uncertainties of thermal diffusivity are less than 6% for all samples at elevated temperatures. The results indicate that single laser surface heating could be convenient and practical for the application of the LFA measurements without extra uncertainty, as temperature dependence of thermal diffusivity is usually negligible in the sample. Moreover, it is concluded that unequal surface treatment, i.e., high absorption on the front side and low emission on the rear side, greatly improves the measurement in serval aspects: less power requirement of the CW laser, less uncertainty of measured thermal diffusivity, and more uniform temperature distribution in the sample. The result of this research can be used as a general guideline for the design of this type of measurement system for nuclear applications. It can also be used directly to design and build a system similar to the one implemented in this project.

36 MATERIALS SCIENCE↗

Uncertainty quantification and sensitivity analysis of a nuclear thermal propulsion reactor startup sequence

The research presented in this article describes progress in applying stochastic methods, uncertainty quantification, parametric studies, and variance-based sensitivity analysis (also known as Sobol sensitivity analysis) to a full-core model of a nuclear thermal propulsion (NTP) system simulated via the radiation transport code Griffin to simulate neutronics. Our goal is to develop a reduced-order (surrogate) model that can be rapidly sampled with perturbations to multiple input parameters. In this NTP system, reactivity and power feedback affect the rotation of control drums (CDs), which is itself controlled by a hybrid proportional-integral-derivative (PID) controller actuated by the power demand and reactivity feedback from the numerical model. This model uses reactor kinetic feedback (mean generation time [Λ] and effective delayed neutron fraction [ β eff ] from a transient Griffin simulation executed via Griffin’s improved quasi-static solver to provide the kinetic parameters) as inputs to functions that control the CD rotation angle. By investigating numerous stochastic approaches, we developed a dual-purpose surrogate model of the NTP system, using polynomial regression in the Multiphysics Object-Oriented Simulation Environment (MOOSE) Stochastic Tools Module (STM). The trained model can be rapidly sampled while simultaneously perturbing various input parameters, such as coefficients on the PID control or temperature (directly affecting the neutron cross section). The surrogate model delivers accurate (within 5%) results at speeds orders of magnitude faster (minutes, not days of computational time) than the base model. Once the surrogate model has been trained, distributions of the uncertain parameters can be changed at will to investigate the effects of perturbing multiple inputs as well as the effects of these inputs on the model output. For example, coefficients used in the PID control system may vary due to some type of physical interference, or uncertainty may exist in the temperature of the neutron cross sections in various regions of the reactor. A distribution can be placed on these parameters, and operational boundaries can be determined. The goal of this work is to support development of an advanced control system for operating CDs in a functioning NTP system. This work is a scoping study of the MOOSE STM.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

ZTF SN Ia DR2 follow-up: Exploring the origin of the Type Ia supernova host galaxy step through Si II velocities

The relation between Type Ia supernovae (SNe Ia) and the stellar masses of their host galaxy is well documented. In particular, Hubble residuals display a distinct luminosity shift based on host mass. This is known as the mass step. This effect is widely used as an additional correction factor in the standardisation of SN Ia luminosities. We investigate the Hubble residuals and the mass step of normal SNe Ia in the context of Si IIλ6355 velocities based on 277 normal SNe Ia that are near their peak in the second data release (DR2) of the Zwicky Transient Facility (ZTF). We divided the sample into high-velocity (HV) and normal-velocity (NV) SNe Ia, separated at 12,000 km s −1 . This produced a sample of 70 HV and 207 NV objects. We then explored potential environment- and/or progenitor-related effects by investigating the Si IIλ6355 velocities with parameters such as the light-curve stretch x 1 , the colour c, and the host galaxy properties. Although we only find a marginal difference between the Hubble residuals of HV and NV SNe Ia, the NV mass step is 0.149 ± 0.024 mag (6.3σ). The HV mass step is smaller, 0.046 ± 0.041 mag (1.1σ), and is consistent with zero. The difference between the NV and HV mass steps is modest, at ∼2.2σ. Moreover, the clearest subtype difference appears for SNe in central regions (d DLR < 1), where NV SNe Ia show a large mass step, whereas HV SNe Ia are consistent with no step, yielding a difference of 3.1–3.6σ between NV and HV SNe Ia. We observe a host-colour step for both subtypes. NV SNe Ia show a step of 0.142 ± 0.024 mag (5.9σ), while HV SNe Ia show a step of 0.158 ± 0.042 mag (3.8σ), where the HV SNe Ia step appears to be larger, but the significance is lower because the sample size is smaller. Overall, the NV and HV colour steps are statistically consistent. HV SNe Ia also show modest (∼2.5–3σ) steps in certain subsets, such as those in outer regions (d DLR > 1), whereas NV SNe display stronger environmental trends. Our results indicate that NV SNe Ia appear to be more environmentally sensitive, particularly in central likely metal-rich and older regions, while HV SNe Ia show weaker and subset-dependent trends. This suggests that applying a universal mass-step correction might introduce biases, and that incorporating refined classifications and/or environment-dependent factors, such as the location within the host, might improve future cosmological analyses beyond the standard x 1 and c cuts.

supernovae: general↗