Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Adaptive Data-Driven Deep-Learning Surrogate Model for Frontal Polymerization in Dicyclopentadiene

Frontal polymerization (FP) is a self-sustaining curing process that enables rapid and energy-efficient manufacturing of thermoset polymers and composites. Computational methods conventionally used to simulate the FP process are time-consuming, and repeating simulations are required for sensitivity analysis, uncertainty quantification, or optimization of the manufacturing process. Here, in this work, we develop an adaptive surrogate deep-learning model for FP of dicyclopentadiene (DCPD), which predicts the evolution of temperature and degree of cure orders of magnitude faster than the finite-element method (FEM). The adaptive algorithm provides a strategy to select training samples efficiently and save computational costs by reducing the redundancy of FEM-based training samples. The adaptive algorithm calculates the residual error of the FP governing equations using automatic differentiation of the deep neural network. A probability density function expressed in terms of the residual error is used to select training samples from the Sobol sequence space. The temperature and degree of cure evolution of each training sample are obtained by a 2D FEM simulation. The adaptive method is more efficient and has a better prediction accuracy than the random sampling method. With the well-trained surrogate neural network, the FP characteristics (front speed, shape, and temperature) can be extracted quickly from the predicted temperature and degree-of-cure fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SYSTEMATIC EFFECTS IN INTERFEROMETRIC OBSERVATIONS OF THE COSMIC MICROWAVE BACKGROUND POLARIZATION

The detection of the primordial B-mode spectrum of the polarized cosmic microwave background (CMB) signal may provide a probe of inflation. However, observation of such a faint signal requires excellent control of systematic errors. Interferometry proves to be a promising approach for overcoming such a challenge. In this paper we present a complete simulation pipeline of interferometric observations of CMB polarization, including systematic errors. We employ two different methods for obtaining the power spectra from mock data produced by simulated observations: the maximum likelihood method and the method of Gibbs sampling. We show that the results from both methods are consistent with each other as well as, within a factor of six, with analytical estimates. Several categories of systematic errors are considered: instrumental errors, consisting of antenna gain and antenna coupling errors; and beam errors, consisting of antenna pointing errors, beam cross-polarization, and beam shape (and size) errors. In order to recover the tensor-to-scalar ratio, r, within a 10% tolerance level, which ensures the experiment is sensitive enough to detect the B-signal at r = 0.01 in the multipole range 28 < l < 384, we find that, for a QUBIC-like experiment, Gaussian-distributed systematic errors must be controlled with precisions of |g{sub rms}| = 0.1 for antenna gain, |{epsilon}{sub rms}| = 5 Multiplication-Sign 10{sup -4} for antenna coupling, {delta}{sub rms} Almost-Equal-To 0. Degree-Sign 7 for pointing, {zeta}{sub rms} Almost-Equal-To 0. Degree-Sign 7 for beam shape, and {mu}{sub rms} = 5 Multiplication-Sign 10{sup -4} for beam cross-polarization. Although the combined systematic effects produce a tolerance level on r twice as large for an experiment with linear polarizers, the resulting bias in r for a circular experiment is 15% which is still on the level of desirable sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-point nonequilibrium umbrella sampling and associated fluctuation relations

We describe a simple method of umbrella trajectory sampling for Markov chains. The method allows the estimation of large-deviation rate functions, for path-extensive dynamic observables, for an arbitrary number of models within a certain family. The general relationship between probability distributions of dynamic observables of members of this family is an extended fluctuation relation. When the dynamic observable is chosen to be entropy production, members of this family include the forward Markov chain and its time reverse, whose probability distributions are related by the expected simple fluctuation relation.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the continuous dilatometer method of silicon carbide thermometry for passive irradiation temperature determination

Silicon carbide (SiC) is a primary candidate for passive irradiation temperature monitoring, and continuous dilatometry (CD) has been proposed as the key method for extracting irradiation temperatures from SiC thermometry samples. The CD method was evaluated to determine the sensitivity of the technique to the analysis procedure, as well as its accuracy and precision. Analysis found that the CD method had a ±20 °C sensitivity to the algorithm used to determine the irradiation temperatures. Comparison of the CD method with the continuous length change method for SiC thermometry showed CD is a more viable method of extracting irradiation temperatures. In conclusion, a comparison of irradiation temperatures determined by CD with those from active thermocouple measurements further validated the CD method for accurately and precisely determining irradiation temperatures in materials test reactor irradiations.

36 MATERIALS SCIENCE↗

Understanding and Modeling Lossy Compression Schemes on HPC Scientific Data

Scientific simulations generate large amounts of floating-point data, which are often not very compressible using the traditional reduction schemes, such as deduplication or lossless compression. The emergence of lossy floating-point compression holds promise to satisfy the data reduction demand from HPC applications; however, lossy compression has not been widely adopted in science production. We believe a fundamental reason is that there is a lack of understanding of the benefits, pitfalls, and performance of lossy compression on scientific data. In this paper, we conduct a comprehensive study on state-of-the-art lossy compression, including ZFP, SZ, and ISABELA, using real and representative HPC datasets. Our evaluation reveals the complex interplay between compressor design, data features and compression performance. The impact of reduced accuracy on data analytics is also examined through a case study of fusion blob detection, offering domain scientists with the insights of what to expect from fidelity loss. Furthermore, the trial and error approach to understanding compression performance involves substantial compute and storage overhead. To this end, we propose a sampling based estimation method that extrapolates the reduction ratio from data samples, to guide domain scientists to make more informed data reduction decisions.

Lu, Tao↗

Effective sampling-driven performance tools for GPU-accelerated supercomputers, In: SC '13 Proceedings of the International Conference on High Performance Computing, Networking, Storage and Analysis

Performance analysis of GPU-accelerated systems requires a system-wide view that considers both CPU and GPU components. In this paper, we describe how to extend system-wide, sampling-based performance analysis methods to GPU-accelerated systems. Since current GPUs do not support sampling, our implementation required careful coordination of instrumentation-based performance data collection on GPUs with sampling-based methods employed on CPUs. In addition, we also introduce a novel technique for analyzing systemic idleness in CPU/GPU systems. We demonstrate the effectiveness of our techniques with application case studies on Titan and Keeneland. Some of the highlights of our case studies are: 1) we improved performance for LULESH 1.0 by 30%, 2) we identified a hardware performance problem on Keeneland, 3) we identified a scaling problem in LAMMPS derived from CUDA initialization, and 4) we identified a performance problem that is caused by GPU synchronization operations that suffer delays due to blocking system calls.

Computer Science↗

Methods for Data-based Delineation of Spatial Regions

In data analysis, it is often useful to delineate or segregate areas of interest from the general population of data in order to concentrate further analysis efforts on smaller areas. Three methods are presented here for automatically generating polygons around spatial data of interest. Each method addresses a distinct data type. These methods were developed for and implemented in the sample planning tool called Visual Sample Plan (VSP). Method A is used to delineate areas of elevated values in a rectangular grid of data (raster). The data used for this method are spatially related. Although VSP uses data from a kriging process for this method, it will work for any type of data that is spatially coherent and appears on a regular grid. Method B is used to surround areas of interest characterized by individual data points that are congregated within a certain distance of each other. Areas where data are “clumped” together spatially will be delineated. Method C is used to recreate the original boundary in a raster of data that separated data values from non-values. This is useful when a rectangular raster of data contains non-values (missing data) that indicate they were outside of some original boundary. If the original boundary is not delivered with the raster, this method will approximate the original boundary.

Algorithm↗

Estimating the Adequacy of a Multi-Objective Optimization

Multi-objective optimization methods can be criticized for lacking a statistically valid measure of the quality and representativeness of a solution. This stance is especially relevant to metaheuristic optimization approaches but can also apply to other methods that typically might only report a small representative subset of a Pareto frontier. Here we present a method to address this deficiency based on random sampling of a solution space to determine, with a specified level of confidence, the fraction of the solution space that is surpassed by an optimization. The Superiority of Multi-Objective Optimization to Random Sampling, or SMORS method, can evaluate quality and representativeness using dominance or other measures, e.g., a spacing measure for high-dimensional spaces. SMORS has been tested in a combinatorial optimization context using a genetic algorithm but could be useful for other optimization methods.

42 ENGINEERING↗

Considerations in the design of life sciences research facilities for the Space Station

The facilities required for life science research on a permanent Space Station are examined. Specifications important to the designing of facilities and planning of activities on the Space Shuttle are: (1) the species to be tested, (2) the number and procedure for testing, (3) the number of specimens at each sampling time, (4) the analyses required, (5) the methods of preserving samples, instruments, and supplies, and (6) the amount of crew time required. Experiments which are relevant to understanding the effects of microgravity on living systems are to be performed on the Space Station. The design and instruments of a Space Station laboratory and specimen centrifuge are described.

Heinrich, M.↗

Development of improved space sampling strategies for ocean chemical properties: Total carbon dioxide and dissolved nitrate

Large-scale ocean observing programs such as the Joint Global Ocean Flux Study (JGOFS) and the World Ocean Circulation Experiment (WOCE) today, must face the problem of designing an adequate sampling strategy. For ocean chemical variables, the goals and observing technologies are quite different from ocean physical variables (temperature, salinity, pressure). We have recently acquired data on the ocean CO2 properties on WOCE cruises P16c and P17c that are sufficiently dense to test for sampling redundancy. We use linear and quadratic interpolation methods on the sampled field to investigate what is the minimum number of samples required to define the deep ocean total inorganic carbon (TCO2) field within the limits of experimental accuracy (+/- 4 micromol/kg). Within the limits of current measurements, these lines were oversampled in the deep ocean. Should the precision of the measurement be improved, then a denser sampling pattern may be desirable in the future. This approach rationalizes the efficient use of resources for field work and for estimating gridded (TCO2) fields needed to constrain geochemical models.

Goyet, Catherine↗

Microstructural Study of Micron-Sized Craters Simulating Stardust Impacts in Aluminum 1100 Targets

Various microscopic techniques were used to characterize experimental micro- craters in aluminium foils to prepare for the comprehensive analysis of the cometary and interstellar particle impacts in aluminium foils to be returned by the Stardust mission. First, SEM (Scanning Electron Microscopy) and EDS (Energy Dispersive X-ray Spectroscopy) were used to study the morphology of the impact craters and the bulk composition of the residues left by soda-lime glass impactors. A more detailed structural and compositional study of impactor remnants was then performed using TEM (Transmission Electron Microscopy), EDS, and electron diffraction methods. The TEM samples were prepared by Focused Ion Beam (FIB) methods. This technique proved to be especially valuable in studying impact crater residues and impact crater morphology. Finally, we also showed that InfraRed microscopy (IR) can be a quick and reliable tool for such investigations. The combination of all of these tools enables a complete microscopic characterization of the craters.

Leroux, Hugues↗

Capillary absorption spectrometer and process for isotopic analysis of small samples

A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The method also permits sampling in vivo permitting real-time ambient studies of microbial communities.

47 OTHER INSTRUMENTATION↗

Benefits of a Biological Monitoring Program for Assessing Remediation Performance and Long-Term Stewardship - 12272

The Biological Monitoring and Abatement Program (BMAP) is a long-running program that was designed to evaluate biological conditions and trends in waters downstream of Department of Energy (DOE) facilities in Oak Ridge, Tennessee. BMAP monitoring has focused on aquatic pathways from sources to biota, which is consistent with the sites' clean water regulatory focus and the overall cleanup strategy which divided remediation areas into watershed administrative units. Specific programmatic goals include evaluating operational and legacy impacts to nearby streams and the effectiveness of implemented remediation strategies at the sites. The program is characterized by consistent, long-term sampling and analysis methods in a multidisciplinary and quantitative framework. Quantitative sampling has shown conclusively that at most Oak Ridge stream sites, fish and aquatic macro-invertebrate communities have improved considerably since the 1980s. Monitoring of mercury and PCBs in fish has shown that remedial and abatement actions have also improved stream conditions, although in some cases biological monitoring suggests further actions are needed. Follow-up investigations have been implemented by BMAP to identify sources or causes, consistent with an adaptive management approach. Biological monitoring results to date have not only been used to assess regulatory compliance, but have provided additional benefits in helping address other components of the DOE's mission, including facility operations, natural resource, and scientific goals. As a result the program has become a key measure of long-term trends in environmental conditions and of high value to the Oak Ridge environmental management community, regulators, and the public. Some of the BMAP lessons learned may be of value in the design, implementation, and application of other long-term monitoring and stewardship programs, and assist environmental managers in the assessment and prediction of the effectiveness of remedial actions and pollution abatement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Open Port Sampling Interface for Liquid Introduction Atmospheric Pressure Ionization Mass Spectrometry

RATIONALE: A simple method to introduce unprocessed samples into a solvent for rapid characterization by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The continuous flow, self-cleaning open port sampling interface introduced here fills this void. METHODS: The open port sampling interface used a vertically aligned, co-axial tube arrangement enabling solvent delivery to the sampling end of the device through the tubing annulus and solvent aspiration down the center tube and into the mass spectrometer ionization source via the commercial APCI emitter probe. The solvent delivery rate to the interface was set to exceed the aspiration rate creating a continuous sampling interface along with a constant, self-cleaning spillover of solvent from the top of the probe. RESULTS: Using the open port sampling interface with positive ion mode APCI and a hybrid quadrupole time of flight mass spectrometer, rapid, direct sampling and analysis possibilities are exemplified with plastics, ballpoint and felt tip ink pens, skin, and vegetable oils. These results demonstrated that the open port sampling interface could be used as a simple, versatile and self-cleaning system to rapidly introduce multiple types of unprocessed, sometimes highly concentrated and complex, samples into a solvent flow stream for subsequent ionization and analysis by mass spectrometry. The basic setup presented here could be incorporated with any self-aspirating liquid introduction ionization source (e.g., ESI, APCI, APPI, ICP, etc.) or any type of atmospheric pressure sampling ready mass spectrometer system. CONCLUSIONS: The open port sampling interface provides a means to introduce and quickly analyze unprocessed solid or liquid samples with liquid introduction atmospheric pressure ionization source without fear of sampling interface or ionization source contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid Radiochemical Analyses in Support of Fukushima Nuclear Accident - 13196

There is an increasing need to develop faster analytical methods for emergency response, including emergency soil and air filter samples [1, 2]. The Savannah River National Laboratory (SRNL) performed analyses on samples received from Japan in April, 2011 as part of a U.S. Department of Energy effort to provide assistance to the government of Japan, following the nuclear event at Fukushima Daiichi, resulting from the earthquake and tsunami on March 11, 2011. Of particular concern was whether it was safe to plant rice in certain areas (prefectures) near Fukushima. The primary objectives of the sample collection, sample analysis, and data assessment teams were to evaluate personnel exposure hazards, identify the nuclear power plant radiological source term and plume deposition, and assist the government of Japan in assessing any environmental and agricultural impacts associated with the nuclear event. SRNL analyzed approximately 250 samples and reported approximately 500 analytical method determinations. Samples included soil from farmland surrounding the Fukushima reactors and air monitoring samples of national interest, including those collected at the U.S. Embassy and American military bases. Samples were analyzed for a wide range of radionuclides, including strontium-89, strontium-90, gamma-emitting radionuclides, and plutonium, uranium, americium and curium isotopes. Technical aspects of the rapid soil and air filter analyses will be described. The extent of radiostrontium contamination was a significant concern. For {sup 89,90}Sr analyses on soil samples, a rapid fusion technique using 1.5 gram soil aliquots to enable a Minimum Detectable Activity (MDA) of <1 pCi {sup 89,90}Sr /g of soil was employed. This sequential technique has been published recently by this laboratory for actinides and radiostrontium in soil and vegetation [3, 4]. It consists of a rapid sodium hydroxide fusion, pre-concentration steps using iron hydroxide and calcium fluoride precipitations, followed by Sr-Resin separation and gas flow proportional counting. To achieve a lower detection limit for analysis of some of the Japanese soil samples, a 10 gram aliquot of soil was taken, acid-leached and processed with similar preconcentration chemistry. The MDA using this approach was ∼0.03 pCi/g (1.1 mBq/g)/, which is less than the 0.05-0.10 pCi/g {sup 90}Sr levels found in soil as a result of global fallout. The chemical yields observed for the Japanese soil samples was typically 75-80% and the laboratory control sample (LCS) and matrix spike (MS) results looked very good for this work Individual QC results were well within the ± 25% acceptable range and the average of these results does not show significant bias. Additional data for a radiostrontium in soil method for 50 gram samples will also be presented, which appears to be a significant step forward based on looking at the current literature, with higher chemical yields for even larger sample aliquots and lower MDA [5, 6, 7] Hou et al surveyed a wide range of separation methods for Pu in waters and environmental solid samples [8]. While there are many actinide methods in the scientific literature, few would be considered rapid due to the tedious and time-consuming steps involved. For actinide analyses in soil, a new rapid method for the determination of actinide isotopes in soil samples using both alpha spectrometry and inductively-coupled plasma mass spectrometry was employed. The new rapid soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using these two simple precipitations with high chemical recoveries and effective removal of interferences. [9, 10] Vacuum box technology and rapid flow rates were used to reduce analytical time. Challenges associated with the mineral content in the volcanic soil will be discussed. Air filter samples were reported within twenty-four (24) hours of receipt using rapid techniques published previously. [11] The rapid reporting of high quality analytical data arranged through the U.S. Department of Energy Consequence Management Home Team was critical to allow the government of Japan to readily evaluate radiological impacts from the nuclear reactor incident to both personnel and the environment. SRNL employed unique rapid methods capability for radionuclides to support Japan that can also be applied to environmental, bioassay and waste management samples. New rapid radiochemical techniques for radionuclides in soil and other environmental matrices as well as some of the unique challenges associated with this work will be presented that can be used for application to environmental monitoring, environmental remediation, decommissioning and decontamination activities. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sample Return Container Opening Process Concept for Potential Mars Sample Return

Proposed Mars Sample Return (MSR) missions would require a pristine and secure opening method to ensure sample Contamination Control and backward Planetary Protection. In order to reach the samples, a series of five containers would need to be opened inside of a Mars Returned Sample Handling (MRSH) facility. The process would include opening the Containment Assurance Module (CAM) aboard the Earth Entry Vehicle (EEV), the Secondary Containment Vessel (SCV), Primary Containment Vessel (PCV), and the Orbiting Sample (OS) container, and finally removing and opening the Returned Sample Tube Assemblies (RSTA). Some of these containers can be opened by reversing the mechanical assembly process while others would require destructive means. Several containers are still in a conceptual design phase while others are en route to Mars aboard the M2020 rover. In order to inform the design of the containers that are still in the conceptual stages, a study was performed at each level of the containment assembly. The studies were used to determine the least destructive and most robust methods to disassemble and open the containers while minimizing risk to the samples or the personnel. In addition to the envisioned disassembly and breaching method, contingency plans were made for completing the disassembly if damage to the vehicle and containment system occurred.

Liu, Yang↗

Comparative Results of Using Different Methods for Discovery of Microorganisms in very Ancient Layers of the Central Antarctic Glacier above the Lake Vostok

The ice sheet of the Central Antarctic is considered by the scientific community worldwide, as a model to elaborate on different methods to search for life outside Earth. This became especially significant in connection with the discovery of the underglacial lake in the vicinity of the Russian Antarctic Station Vostok. Lake Vostok is considered by many scientists as an analog of the ice covered seas of Jupiter's satellite Europa. According to the opinion of many researchers there is the possibility that relict forms of microorganisms, well preserved since the Ice Age, may be present in this lake. Investigations throughout the thickness of the ice sheet above Lake Vostok show the presence of microorganisms belonging to different well-known taxonomic groups, even in the very ancient horizons near close to floor of the glacier. Different methods were used to search for microorganisms that are rarely found in the deep ancient layers of an ice sheet. The method of aseptic sampling from the ice cores and the results of controlled sterile conditions in all stages when conducting these investigations, are described in detail in previous reports. Primary investigations tried the usual methods of sowing samples onto different nutrient media, and the result was that only a few microorganisms grew on the media used. The possibility of isolating the organisms obtained for further investigations, by using modern methods including DNA-analysis, appears to be the preferred method. Further investigations of the very ancient layers of the ice sheet by radioisotopic, luminescence, and scanning electron microscopy methods at different modifications, revealed the quantity and morphological diversity of the cells of microorganisms that were distributed on the different horizons. Investigations over many years have shown that the microflora in the very ancient strata of the Antarctic ice cover, nearest to the bedrock, support the effectiveness of using a combination of different methods to search for signs of life in ancient icy formations, which might play a role in the long-term preservation and transportation of microbial life throughout the Universe.

Abyzov, S. S.↗

A deterministic alternative to the full configuration interaction quantum Monte Carlo method

Development of exponentially scaling methods has seen great progress in tackling larger systems than previously thought possible. One such approach, full configuration interaction quantum Monte Carlo, is a useful algorithm that allows exact diagonalization through stochastically sampling determinants. The method derives its utility from the information in the matrix elements of the Hamiltonian, along with a stochastic projected wave function, to find the important parts of Hilbert space. Yet, the stochastic representation of the wave function is not required to search Hilbert space efficiently, and here we describe a highly efficient deterministic method that can achieve chemical accuracy for a wide range of systems, including the difficult Cr 2 molecule. We demonstrate for systems like Cr 2 that such calculations can be performed in just a few cpu hours which makes it one of the most efficient and accurate methods that can attain chemical accuracy for strongly correlated systems. Furthermore, our method also allows efficient calculation of excited state energies, which we illustrate with benchmark results for the excited states of C 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗