Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

THE DISKMASS SURVEY. I. OVERVIEW

We present a survey of the mass surface density of spiral disks, motivated by outstanding uncertainties in rotation-curve decompositions. Our method exploits integral-field spectroscopy to measure stellar and gas kinematics in nearly face-on galaxies sampled at 515, 660, and 860 nm, using the custom-built SparsePak and PPak instruments. A two-tiered sample, selected from the UGC, includes 146 nearly face-on galaxies, with B < 14.7 and disk scale lengths between 10 and 20 arcsec, for which we have obtained H{alpha} velocity fields; and a representative 46 galaxy subset for which we have obtained stellar velocities and velocity dispersions. Based on re-calibration of extant photometric and spectroscopic data, we show that these galaxies span factors of 100 in L{sub K} (0.03 < L/L* {sub K} < 3), 8 in L{sub B} /L{sub K} , 10 in R-band disk central surface brightness, with distances between 15 and 200 Mpc. The survey is augmented by 4-70 {mu}m Spitzer IRAC and MIPS photometry, ground-based UBVRIJHK photometry, and H I aperture-synthesis imaging. We outline the spectroscopic analysis protocol for deriving precise and accurate line-of-sight stellar velocity dispersions. Our key measurement is the dynamical disk-mass surface density. Star formation rates and kinematic and photometric regularity of galaxy disks are also central products of the study. The survey is designed to yield random and systematic errors small enough (1) to confirm or disprove the maximum-disk hypothesis for intermediate-type disk galaxies, (2) to provide an absolute calibration of the stellar mass-to-light ratio well below uncertainties in present-day stellar-population synthesis models, and (3) to make significant progress in defining the shape of dark halos in the inner regions of disk galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Investigation of Mechanical Performance and Printability of Gamma-Irradiated Additively Manufactured ABS

The work presented in this paper investigates the effects of gamma radiation on ABS in forms of irradiated 3D-printed parts, and irradiated filament used to later 3D-printed parts, using a cobalt-60 gamma irradiator. Tensile and flexural test samples were fabricated using off-the-shelf FDM 3D printers and irradiated at different dosages. Mechanical properties including elastic and flexure moduli, ultimate and flexural strength, % elongation at break, and surface hardness were evaluated, and results were compared to a control group. Evidence of cross-linking and chain scission and signs of possible oxidation of polymer caused by irradiation were found in both test groups which led to changes in mechanical properties. Moreover, it was found that ABS filament retains its printability after absorbing 15 kGy of gamma radiation and that its mechanical performance is very similar to those of irradiated samples at the same dose. Obtained results show promise for using ABS to fabricate sterile surgical instruments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface pump-probe femtosecond-laser mass spectrometry: Time-, mass-, and velocity-resolved detection of surface reaction dynamics

A detailed account of the experimental methodology of surface pump-probe femtosecond-laser mass spectrometry is presented. This recently introduced technique enables the direct time-resolved investigation of surface reaction dynamics by monitoring the mass and the relative velocity of intermediates and products of a photoinduced surface reaction via multiphoton ionization. As a model system, the photodissociation dynamics of methyl iodide adsorbed at submonolayer coverage on magnesia ultrathin films is investigated. The magnesia surface preparation and characterization as well as the pulsed deposition of methyl iodide are described. The femtosecond-laser excitation (pump) and, in particular, the resonant multiphoton ionization surface detection (probe) schemas are discussed in detail. Results of pump-probe time-resolved methyl and iodine atom detection experiments are presented and the potential of this method for velocity-resolved photofragment analysis is evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation between crystallization behaviour and interfacial interactions in plasticized PLA/POSS nanocomposites

In this study, the correlation between crystallization behavior and surface chemistry of polyhedral oligomeric silsesquioxanes (POSS) for plasticized poly(lactic acid) (PLA)/POSS nanocomposites was investigated. Four different kinds of POSS particles having different chemical structures were used. Poly(ethylene glycol) (PEG, 8000 g/mol) was utilized as the plasticiser. The nanocomposites were melt-compounded in an Xplore Instruments 15 cc twin screw microcompounder at 180°C barrel temperature and 100 rpm screw speed. Non-isothermal crystallization behaviour of PLA/PEG/POSS nanocomposites were evaluated from common kinetic models such as Avrami and Avrami-Ozawa and Kissinger by using the thermal data obtained from differantial scanning calorimetry (DSC). A polarized optical microscope (POM) equipped with a hot-stage was used to examine the morphology during the crystal growth. In order to investigate the interfacial interactions between POSS particles and plasticized PLA, thermodynamic work of adhesion approach was adopted using the experimentally determined surface energies. A strong correlation was obtained between interfacial chemistry and the nucleation rate in plasticized PLA/POSS nanocomposites. It was found that the polar interactions were the dominating factor which determines the nucleation activity of the POSS particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Applications of TIERRAS for underground particle cascade simulations

In this communication we present some example applications of TIERRAS, a software package for the simulation of High Energy particle cascades underground and underwater. The examples illustrate how this package can be used to study the phenomenology of particle cascades from Extended Air Showers propagated several meters underground, including the effect of the surface ''albedo'' particles that are generated when a cascade reaches ground level. These up-going particles can have a measurable effect on surface or shallow underground detectors. Finally, to show the package ability ro perform simulations of particle cascades in ice, an application for neutrino radio detection is briefly introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equilibrium reconstruction based on core magnetic measurement and its applications on equilibrium transition in Joint-TEXT tokamak

Evaluation and reconstruction of plasma equilibrium, especially to resolve the safety factor profile, is imperative for advanced tokamak operation and physics study. Based on core magnetic measurement by the high resolution laser polarimeter-interferometer system (POLARIS), the equilibrium of Joint-TEXT (J-TEXT) plasma is reconstructed and profiles of safety factor, current density, and electron density are, therefore, obtained with high accuracy and temporal resolution. The equilibrium reconstruction procedure determines the equilibrium flux surfaces essentially from the data of POLARIS. Refraction of laser probe beam, a major error source of the reconstruction, has been considered and corrected, which leads to improvement of accuracy more than 10%. The error of reconstruction has been systematically assessed with consideration of realistic diagnostic performance and scrape-off layer region of plasma, and its accuracy has been verified. Fast equilibrium transitions both within a single sawtooth cycle and during the penetration of resonant magnetic perturbation have been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Electrode Geometry on the Classification Performance of Rapid Evaporative Ionization Mass Spectrometric (REIMS) Bacterial Identification

The recently developed automated, high-throughput monopolar REIMS platform is suited for the identification of clinically important microorganisms. Although already comparable to the previously reported bipolar forceps method, optimization of the geometry of monopolar electrodes, at the heart of the system, holds the most scope for further improvements to be made. For this, sharp tip and round shaped electrodes were optimized to maximize species-level classification accuracy. Following optimization of the distance between the sample contact point and tube inlet with the sharp tip electrodes, the overall cross-validation accuracy improved from 77% to 93% in negative and from 33% to 63% in positive ion detection modes, compared with the original 4 mm distance electrode. As an alternative geometry, round tube shaped electrodes were developed. Geometry optimization of these included hole size, number, and position, which were also required to prevent plate pick-up due to vacuum formation. Additional features, namely a metal “X”-shaped insert and a pin in the middle were included to increase the contact surface with a microbial biomass to maximize aerosol production. Following optimization, cross-validation scores showed improvement in classification accuracy from 77% to 93% in negative and from 33% to 91% in positive ion detection modes. Supervised models were also built, and after the leave 20% out cross-validation, the overall classification accuracy was 98.5% in negative and 99% in positive ion detection modes. This suggests that the new generation of monopolar REIMS electrodes could provide substantially improved species level identification accuracies in both polarity detection modes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A LIBS method for simultaneous monitoring of the impurities and the hydrogenic composition present in the wall of the TJ-II stellarator

The study of plasma-wall interactions and impurity transport in the plasma fusion devices is critical for the development of future fusion reactors. An experiment to perform laser induced breakdown spectroscopy, using minor modifications of our existing laser blow-off impurity injection system, has been set up thus making both experiments compatible. The radiation produced by the laser pulse focused at the TJ-II wall evaporates a surface layer of deposited impurities and the subsequent radiation produced by the laser-produced plasma is collected by two separate lens and fiber combinations into two spectrometers. The first spectrometer, with low spectral resolution, records a spectrum from 200 to 900 nm to give a survey of impurities present in the wall. The second one, with high resolution, is tuned to the wavelengths of the Hα and Dα lines in order to resolve them and quantify the hydrogen isotopic ratio present on the surface of the wall. The alignment, calibration, and spectral analysis method will be described in detail. First experimental results obtained with this setup will be shown and its relevance for the TJ-II experimental program discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emittance characterization of a hot-cavity laser ion source at Holifield Radioactive Ion Beam Facility

The first investigation of the transverse emittance of a hot-cavity laser ion source based on all-solid-state Ti:sapphire lasers is presented. The emittances of {sup 63}Cu ion beams generated by three-photon resonant ionization are measured and compared with that of the {sup 69}Ga and {sup 39}K ion beams resulting from surface ionization in the same ion source. A self-consistent unbiased elliptical exclusion method is adapted for noise reduction and emittance analysis. Typical values of the rms and 90% fractional emittances of the Cu ion beams at 20 keV energy are found to be about 2 and 8 {pi} mm mrad, respectively, for the ion currents of 2-40 nA investigated. The emittances of the laser-produced Cu ion beams are smaller than those of the surface-ionized Ga and K ion beams.

43 PARTICLE ACCELERATORS↗

Fabrication and testing of antimony doped bismuth tri-iodide semiconductor gamma-ray detectors

We fabricated antimony (Sb) doped bismuth tri-iodide (BiI 3 ) radiation detectors from large single crystals that were grown using the modified vertical Bridgman technique. Detectors were prepared by subjecting the crystal surfaces to different mechanical and chemical treatments. Surface quality of the detectors was evaluated using optical microscopy. The influence of surface quality on detector performance was analyzed by measuring the leakage current for each of the detectors. The radiation response of the detectors was measured using an Americium ( 241 Am) gamma-ray source at room temperature. The first successful use of BiI 3 detectors for gamma-ray spectroscopy is reported here with energy resolution of 7.5% at 59.5 keV. The mobility-lifetime product for electrons was also estimated to be about 5.2 x 10 -4 cm 2 /V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modification of ordinary-mode reflectometry system to detect lower-hybrid waves in Alcator C-Mod

Backscattering experiments to detect lower-hybrid (LH) waves have been performed in Alcator C-Mod, using the two modified channels (60 GHz and 75 GHz) of an ordinary-mode reflectometry system with newly developed spectral recorders that can continuously monitor spectral power at a target frequency. The change in the baseline of the spectral recorder during the LH wave injection is highly correlated to the strength of the X-mode non-thermal electron cyclotron emission. In high density plasmas where an anomalous drop in the lower hybrid current drive efficiency is observed, the observed backscattered signals are expected to be generated near the last closed flux surface, demonstrating the presence of LH waves within the plasma. This experimental technique can be useful in identifying spatially localized LH electric fields in the periphery of high-density plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated suppression of errors in LTP-II slope measurements of x-ray optics. Part 2: Specification for automated rotating/flipping/aligning system

Systematic error and instrumental drift are the major limiting factors of sub-microradian slope metrology with state-of-the-art x-ray optics. Significant suppression of the errors can be achieved by using an optimal measurement strategy suggested in [Rev. Sci. Instrum. 80, 115101 (2009)]. With this series of LSBL Notes, we report on development of an automated, kinematic, rotational system that provides fully controlled flipping, tilting, and shifting of a surface under test. The system is integrated into the Advanced Light Source long trace profiler, LTP-II, allowing for complete realization of the advantages of the optimal measurement strategy method. We provide details of the system?s design, operational control and data acquisition. The high performance of the system is demonstrated via the results of high precision measurements with a spherical test mirror.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated suppression of errors in LTP-II slope measurements with x-ray optics. Part1: Review of LTP errors and methods for the error reduction

Systematic error and instrumental drift are the major limiting factors of sub-microradian slope metrology with state-of-the-art x-ray optics. Significant suppression of the errors can be achieved by using an optimal measurement strategy suggested in [Rev. Sci. Instrum. 80, 115101 (2009)]. With this series of LSBL Notes, we report on development of an automated, kinematic, rotational system that provides fully controlled flipping, tilting, and shifting of a surface under test. The system is integrated into the Advanced Light Source long trace profiler, LTP-II, allowing for complete realization of the advantages of the optimal measurement strategy method. We provide details of the system’s design, operational control and data acquisition. The high performance of the system is demonstrated via the results of high precision measurements with a spherical test mirror.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Threshold for Thermal Ionization of an Aluminum Surface by Pulsed Megagauss Magnetic Field

The first measurement of the threshold for thermal ionization of the surface of thick metal by pulsed magnetic field (B) is reported. Thick aluminum - with depth greater than the magnetic skin layer - was pulsed with partial derivB/partial derivt from 30-80 MG/mus. Novel loads avoided nonthermal plasma (from electron avalanche, or energetic particles or photons from arcs). Thermal plasma forms from 6061-alloy aluminum when the surface magnetic field reaches 2.2 MG, in qualitative agreement with numerical simulation results by Garanin et al.[J. Appl. Mech. Tech. Phys. 46, 153 (2005)].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lifetime Extension of the Gas Discharge Detectors with Plasma Etching of Silicon Deposits in 80%CF{sub 4} + 20%CO{sub 2}

A method of elimination of silicon compounds from the anode wire of an aged proportional counter is presented. The aging of a counter with a 70%Ar + 30%CO{sub 2} and a 60%Ar + 30%CO{sub 2} + 10%СF{sub 4} working mixture was stimulated by a {sup 90}Sr β source. To accelerate the process of aging, the gas mixture flow to the counter was supplied through a pipe with RTV coated wall. As a result, the amplitude of the signal decreased 70% already at accumulated charge of Q = 0.03 C/cm. The etching of the silicon compounds on the wire surface with an 80%CF{sub 4} + 20%CO{sub 2} gas mixture discharge led to full recovery of the operating characteristics of detector and an increase in the lifetime. A scanning electron microscopy and X-ray spectroscopy analysis of the recovered wire surface were performed. In accordance with the results, a good quality of wire cleaning from SiO{sub 2} compounds was obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring Young Stars in Space and Time. II. The Pre-main-sequence Stellar Content of N44

The Hubble Space Telescope survey Measuring Young Stars in Space and Time (MYSST) entails some of the deepest photometric observations of extragalactic star formation, capturing even the lowest-mass stars of the active star-forming complex N44 in the Large Magellanic Cloud. We employ the new MYSST stellar catalog to identify and characterize the content of young pre-main-sequence (PMS) stars across N44 and analyze the PMS clustering structure. To distinguish PMS stars from more evolved line of sight contaminants, a non-trivial task due to several effects that alter photometry, we utilize a machine-learning classification approach. This consists of training a support vector machine (SVM) and a random forest (RF) on a carefully selected subset of the MYSST data and categorize all observed stars as PMS or non-PMS. Combining SVM and RF predictions to retrieve the most robust set of PMS sources, we find ∼26,700 candidates with a PMS probability above 95% across N44. Employing a clustering approach based on a nearest neighbor surface density estimate, we identify 16 prominent PMS structures at 1σ significance above the mean density with sub-clusters persisting up to and beyond 3σ significance. The most active star-forming center, located at the western edge of N44's bubble, is a subcluster with an effective radius of ∼5.6 pc entailing more than 1100 PMS candidates. Furthermore, we confirm that almost all identified clusters coincide with known H ii regions and are close to or harbor massive young O stars or YSOs previously discovered by MUSE and Spitzer observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗