Search NASA⌕ Search

SEARCH · Search NASA

Results for “time segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Analysis of fuel-conservative curved decelerating approach trajectories for powered-lift and CTOL jet aircraft

A method for determining fuel conservative terminal approaches that include changes in altitude, speed, and heading are described. Three different guidance system concepts for STOL aircraft were evaluated in flight: (1) a fixed trajectory system; (2) a system that included a fixed path and a real time synthesized capture flight path; and (3) a trajectory synthesizing system. Simulation results for the augmentor wing jet STOL research aircraft and for the Boeing 727 aircraft are discussed. The results indicate that for minimum fuel consumption, two guidance deceleration segments are required.

Neuman, F.↗

Outside users payload model

The outside users payload model which is a continuation of documents and replaces and supersedes the July 1984 edition is presented. The time period covered by this model is 1985 through 2000. The following sections are included: (1) definition of the scope of the model; (2) discussion of the methodology used; (3) overview of total demand; (4) summary of the estimated market segmentation by launch vehicle; (5) summary of the estimated market segmentation by user type; (6) details of the STS market forecast; (7) summary of transponder trends; (8) model overview by mission category; and (9) detailed mission models. All known non-NASA, non-DOD reimbursable payloads forecast to be flown by non-Soviet-block countries are included in this model with the exception of Spacelab payloads and small self contained payloads. Certain DOD-sponsored or cosponsored payloads are included if they are reimbursable launches.

Source record↗

Measurement of pilot workload

A multistage process for evaluating the workload of a five-minute segment of flight including approach and landing for a typical transport aircraft was described. The goal of the analysis was to compare the workload of the two pilots. Four types of measurement techniques were suggested: Analytic (a preliminary task and time line analysis identified task requirements and target performance levels); Performance (flight path control, communications, and interval production); Physiological (heart rate and heart rate variability); and Subjective ratings (a multidimensional technique developed at NASA Ames).

Hart, Sandra G.↗

The 27-28 October 1986 FIRE IFO cirrus case study - Cloud optical properties determined by High Spectral Resolution Lidar

The High Spectral Resolution Lidar (HSRL) was operated from a roof-top site in Madison, Wisconsin. The transmitter configuration used to acquire the case study data produces about 50 mW of ouput power and achieved eye-safe, direct optical depth, and backscatter cross section measurements with 10 min averaging times. A new continuously pumped, injection seeded, frequency doubled Nd:YAG laser transmitter reduces time-averaging constraints by a factor of about 10, while improving the aerosol-molecular signal separation capabilities and wavelength stability of the instrument. The cirrus cloud backscatter-phase functions have been determined for the October 27-28, 1986 segment of the HSRL FIRE dataset. Features exhibiting backscatter cross sections ranging over four orders of magnitude have been observed within this 33 h period. During this period, cirrus clouds were observed with optical thickness ranging from 0.01 to 1.4. The altitude relationship between cloud top and bottom boundaries and the optical center of the cloud is influenced by the type of formation observed.

Grund, C. J.↗

Tracking the Relative Motion of Four Space Payloads Launched from a Sub-Orbital NASA Rocket

One problem, which is comparatively new in the field of GPS applications, is the determination of the relative trajectories of space vehicles. Applications include the docking of spacecraft, collision avoidance in the area of space stations, and trajectory reconstruction of multiple payloads. The required precision in any of these applications will vary, according to the requirements of the task and abilities of GPS to cope with the environment and the dynamics. This paper describes the post-mission reconstruction of the relative trajectories of four GPS receivers attached to four payloads jettisoned from a Black Brant XII rocket. This vehicle was launched by the National Aeronautics and Space Administration (NASA) in January 1999 from the Poker Flats Research Range near Fairbanks, Alaska. The Black Brant XII is a sub-orbital rocket designed to carry payloads of 100 to 500 kg into the upper atmosphere. Flight time is generally in the order of 10-20 minutes. In this experiment, a GPS receiver and antenna was attached to each of the four payloads. One of the GPS receivers was assigned as the "base station", while the other 3 receivers were designated as remotes. GPS time, code and phase measurements were telemetered to a ground station for real-time processing and storage. The object of the mission was to re-compute the position and velocity of the remote units with respect to the base station during the launch phase and after the payloads separated. During the launch segment the 3 baseling distances between the 4 antennas are known from plans and are constant values until each payload is released. On the fly ambiguity determination was used to establish local coordinates from the base antenna to each of the other 3 GPS units during flight. Distance computations were made from the GPS-derived coordinates and compared to plan distances. Using this methodology an error analysis of the relative GPS accuracies has been presented and in addition a description given of the respective payload behaviour following separation from the vehicle.

Martell, Hugh↗

FPGA-based Upgrade to RITS-6 Control System, Designed with EMP Considerations

The existing control system for the RITS-6, a 20-MA 3-MV pulsed-power accelerator located at Sandia National Laboratories, was built as a system of analog switches because the operators needed to be close enough to the machine to hear pulsed-power breakdowns, yet the electromagnetic pulse (EMP) emitted would disable any processor-based solutions. The resulting system requires operators to activate and deactivate a series of 110-V relays manually in a complex order. The machine is sensitive to both the order of operation and the time taken between steps. A mistake in either case would cause a misfire and possible machine damage. Based on these constraints, a field-programmable gate array (FPGA) was chosen as the core of a proposed upgrade to the control system. An FPGA is a series of logic elements connected during programming. Based on their connections, the elements can mimic primitive logic elements, a process called synthesis. The circuit is static; all paths exist simultaneously and do not depend on a processor. This should make it less sensitive to EMP. By shielding it and using good electromagnetic interference-reduction practices, it should continue to operate well in the electrically noisy environment. The FPGA has two advantages over the existing system. In manual operation mode, the synthesized logic gates keep the operators in sequence. In addition, a clock signal and synthesized countdown circuit provides an automated sequence, with adjustable delays, for quickly executing the time-critical portions of charging and firing. The FPGA is modeled as a set of states, each state being a unique set of values for the output signals. The state is determined by the input signals, and in the automated segment by the value of the synthesized countdown timer, with the default mode placing the system in a safe configuration. Unlike a processor-based system, any system stimulus that results in an abort situation immediately executes a shutdown, with only a tens-of-nanoseconds delay to propagate across the FPGA. This paper discusses the design, installation, and testing of the proposed system upgrade, including failure statistics and modifications to the original design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rolling Root Mean Square Based Multimodal Anomaly Detection for Real Time Monitoring of Smart Grid

Reliable real-time monitoring is valuable for maintaining the operational integrity of modern electrical smart grids. Deployment of heterogeneous sensing technologies in substations has enabled high-resolution, multichannel waveform monitoring, but also introduces challenges for anomaly detection due to noise, baseline drift, and modality-dependent signal characteristics. In this work, we present a computationally efficient unsupervised method for multimodal event detection based on Rolling Root Mean Square based Event Detection (RRMSED). The method is developed using in-house, field deployed sensors collecting data at a utility substation. The sensing system comprises voltage and current sensors, triaxial accelerometers, and magnetometers, collectively capturing electrical, vibrational, and magnetic waveform measurements at high temporal resolution. RRMSED operates by extracting rolling RMS energy features and their first-order temporal differences from consecutive waveform segments for each channel and then applying channel-specific statistical thresholds learned from historical data. A persistence-based exceedance logic is employed to robustly identify transient events while suppressing impulsive noise, and to provide precise temporal localization with high resolution. The framework is designed for continuous server-side operation and can be deployed in real time without requiring complex models. Experiments on simulated waveform data with known ground truth demonstrate low false positive (FP) and false negative (FN) rates. Application to real substation data shows RRMSED to identify events that are not captured by conventional monitoring indicators including fast transient detection algorithm currently deployed in the system. These results indicate that rolling RMS based features provide an effective and practical basis for real-time multimodal event detection in smart-grid substations.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

The Solar-Stellar Connection (NAG5-6124: SOHO Guest Investigator Program)

The following is a final report from the SOHO Guest Investigator program to use the SUMER far-UV spectrometer to obtain imaging spectroscopy in support of the goals of the so-called "solar-stellar connection." In particular, a major emphasis was utilization of the long-slit time-resolved maps of the solar surface in bright far-UV emission lines to deduce how particular aspects of the temporally and spatially averaged line profiles trace back to individual structural features of the magnetically disturbed outer atmosphere; to help interpret the unresolved line profiles from high quality stellar observations (say, with the Space Telescope Imaging Spectrograph). The researchers served two tours of duty in the SOHO Operations Center as SUMER planners, during which time we conducted an extensive series of observing programs. These can be divided into three general categories: surface mapping, translimb spectroscopy, and active region diagnostics. We have analyzed some of the large volumes of data to the point where we have presented them in poster papers, and in invited papers at national and international meetings. Listed below are the titles of the preliminary publications we have written, including brief abstracts to indicate the main results. (1) Chromospheric structure and Dynamics-- Observations -- The chromosphere is a highly structured dynamic 'layer' of the solar outer atmosphere. Here, not only are the effects of mechanical heating first evident (moving upward in altitude from the deep photosphere), but also the amount of nonradiative energy deposited is far greater than in the albeit much hotter overlying transition region and corona. Further, the chromosphere is by far the thickest zone of the solar atmosphere with respect to the pressure scale height. A major goal of stellar astrophysics is to understand how the chromosphere is heated and why it adopts its peculiar structure. A cursory examination of solar filtergrams and high-resolution movies demonstrates that much of the chromospheric "action" must be occurring on fine spatial scales and short times; particularly in the cell interior transient brightenings, but also in the longer-lived network fragments. That regime of investigation is far removed from what one usually associates with "synoptic" measurements. Nevertheless, synoptic observations of chromospheric indices, filtergrams, and globally-averaged profile parameters not only can provide important insight concerning the crucial role of the cycle-variable part of the solar magnetic field; but they also can forge a key link with analogous measurements of the stars, where often the phenomena can be significantly exaggerated from the solar case, but high spatial resolution reconnaissance is not even a remote possibility. In addition to discussing the synoptic aspects of chromospheric structure and dynamics, I summarized new insights into the general problem of the solar chromosphere that have been obtained recently with the SUMER far-ultraviolet spectrometer on SOHO. (2) CO and the Temperature Structure of the Solar Atmosphere -- The surface layers of the Sun provide a crucial boundary condition for many of the processes that occur in the deep interior. The stratification of the outer solar atmosphere once was thought to be well understood. However, studies of thermally sensitive molecular absorptions in the infrared revealed puzzling anomalies. Strong lines of the CO fundamental vibration-rotation bands near 5 microns showed very cool temperatures at the extreme limb, and remarkable off-limb emissions extending well into the supposedly hot chromosphere. The conflicting pictures of the photosphere/chromosphere interface, from the widely separated wavelength regimes, has raised suspicions that those "layers" of the atmosphere are much more inhomogeneous than previously suspected. One proposal is that the low chromosphere is dominated by cool gas, the "COmosphere," which is threaded by a network of persistent small-scale hot magnetic filaments and occasionally disrupted by localized acoustic disturbances. The COmosphere is capped by the merged fields of the network elements in the chromospheric "canopy." (3) Translimb Spectroscopy with SOHO/SUMER -- We have used SUMER to obtain deep exposures of the 1300-1400 A spectrum, at the extreme limb and off-limb. Previous "translimb" studies in the thermal infrared had revealed remarkable extensions of cold material (T is approximately equal to 3000 K)-traced by carbon monoxide emission lines-into the heart of the hot chromosphere. A main objective of our program was to search for corresponding far-UV signatures of the "thermally-bifurcated" low chromosphere; for example, radiatively fluoresced emissions of the CO A-X 4th-positive system (collisional excitation would be negligible in cold gas). We conducted two separate observing programs with SUMER. Both made use of the 1 inch-diameter circular aperture, translated across the limb in the minimum motor step increments of 0."375, along the central meridian in the Northern polar coronal hole. The first program executed for nine hours beginning 19UT 25 Oct 1996. The full wavelength range was 1340-1400 A. It was recorded in two overlapping segments, placing key regions of the spectrum alternately on the KBr and bare parts of the detector, to help isolate 2nd-order features. Each segment was integrated for 500 s, and 32 pairs were obtained to span a 12" swath centered on the optical limb. The second program was conducted 00-09UT 01 Dec 1996. It consisted of a single wavelength setting (1300-1340 A) with exposure time 500 s, but twice the spatial coverage of the earlier series: 64 steps, for a total displacement of 24". The strong chromospheric resonance lines of atomic oxygen (1302-1305 A) and ionized carbon (1334-1335 A) were observed on the bare part of the MCP camera.

Ayres, Thomas R.↗

Optimal control model of technology transition.

This paper discusses the use of optimization software to solve an optimal control problem arising in the modeling of technology transition. We set up a series of increasingly complex models with such features as learning-by-doing, adjustment cost, and capital investment. The models are written in continuous time and then discretized by using different methods to transform them into large-scale nonlinear programs. We use a modeling language and numerical optimization methods to solve the optimization problem. Our results are consistent with findings in the literature and highlight the impact the discretization choice has on the solution and accuracy. The primary goal of this paper is to develop solution methods for use in policy work. To do this, we will need to expand the model to include realistic features such as additional technologies and capital conversion. Our modeling approach allows us to add new technologies with minimal effort. For example, Figure 5 presents the solution to the capital model that includes a third technology, say, nuclear fusion, that is emission free but even more expensive (A{sub 3} > A{sub n}). We observe that industry first transitions to the intermediate technology but eventually adopts the cleanest one. We note that our solutions have few areas of large curvature and are relatively smooth elsewhere. On such smooth segments, we can achieve adequate precision with relatively large periods, which means fewer variables and increased computation speed. But we still need a small step length during the transition period. Adaptive mesh refinement methods have been developed to automatically identify the areas where extra precision is needed. Betts (2001) describes how the computation time can be reduced by a factor of 2.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sensors for Using Times of Flight to Measure Flow Velocities

Thin-film sensors for measuring flow velocities in terms of times of flight are undergoing development. These sensors are very small and can be mounted flush with surfaces of airfoils, ducts, and other objects along which one might need to measure flows. Alternatively or in addition, these sensors can be mounted on small struts protruding from such surfaces for acquiring velocity measurements at various distances from the surfaces for the purpose of obtaining boundary-layer flow-velocity profiles. These sensors are related to, but not the same as, hot-wire anemometers. Each sensor includes a thin-film, electrically conductive loop, along which an electric current is made to flow to heat the loop to a temperature above that of the surrounding fluid. Instantaneous voltage fluctuations in segments of the loop are measured by means of electrical taps placed at intervals along the loop. These voltage fluctuations are caused by local fluctuations in electrical resistance that are, in turn, caused by local temperature fluctuations that are, in turn, caused by fluctuations in flow-induced cooling and, hence, in flow velocity. The differential voltage as a function of time, measured at each pair of taps, is subjected to cross-correlation processing with the corresponding quantities measured at other pairs of taps at different locations on the loop. The cross-correlations yield the times taken by elements of fluid to travel between the pairs of taps. Then the component of velocity along the line between any two pairs of taps is calculated simply as the distance between the pairs of taps divided by the travel time. Unlike in the case of hot-wire anemometers, there is no need to obtain calibration data on voltage fluctuations versus velocity fluctuations because, at least in principle, the correlation times are independent of the calibration data.

Fralick, Gutave↗

The Evolution of Team-X: 25 Years of Concurrent Engineering Design Experience

Established in 1995 in response to NASA’s “Faster, Better, Cheaper” era, Team-X was born from a need to perform rapid space mission design for principal investigator-led competed proposals. The success and sustainability of Team-X over the 25 years that have followed is directly attributable to the Team-X business model and its evolution over time. While dozens of organizations and institutions have emulated the Team-X design process, there are nuances to the Team-X business model that are unique to JPL, and explain why it is different than other concurrent design teams. One of the key components of a business model is the customer segments that are served. Team-X was founded to conduct the Pre-Phase A work necessary to formulate a portfolio of multiple planetary mission concepts, but has since expanded to include the capability to conduct studies for Earth science, astrophysics, and heliophysics missions as well as Human Exploration and Operations missions and space technology development. Team-X delivers value to its clients both in terms of speed and cost. Team-X has also added value by creating teams to enable the development of Instrument and SmallSat Concepts. Value has further been enhanced through a revision of its process for reviews and the addition of pre-design architecting capabilities. Other aspects of the Team-X infrastructure, in addition to study process, have enabled it to succeed for over a quarter century. From our most important resource, the people, our tools, especially for cost estimating, as well as our increasing capable IT infrastructure have contributed to our capability to meet the demands of our clients. The Team-X business model and its evolution over time, position it well for success in the decades to come.

Murphy, Jonathan↗

TU-F-CAMPUS-I-02: Contrast Enhanced Cone Beam CT Imaging with Dual- Gantry Image Acquisition and Constrained Iterative Reconstruction-a Simulation Study for Liver Imaging Application

Purpose: Contrast time-density curves may help differentiate malignant tumors from normal tissues or benign tumors. Repetitive scans using conventional CT or cone beam CT techniques, which Result in unacceptably high dose, may not achieve the desired temporal resolution. In this study we describe and demonstrate a 4D imaging technique for imaging and quantifying contrast flows requiring only one or two 360° scans. Methods: A dual-gantry system is used to simultaneously acquire two projection images at orthogonal orientations. Following the scan, each or both of the two 360° projection sets are used to reconstruct an average contrast enhanced image set which is then segmented to form a 3D contrast map. Alternatively, a pre-injection scan may be made and used to reconstruct a pre-injection image set which is subtracted from the post-injection image set to form the 3D contrast map. Each of the two 360° projection sets is divided into 12 subsets, thus creating 12 pairs of 30° limited angle projection sets, each corresponding to a time spanning over 1/12 of the scanning time. Each pair of the projection sets are reconstructed as a time specific 3D image set with the maximum likelihood estimation iterative algorithm using the contrast map as the constraint. As a demonstration, a 4D abdominal phantom was constructed from clinical CT images with blood flow through the normal tissue and a tumor modeled and imaging process simulated. Results: We have successfully generated a 4D image phantom, and calculated the projection images. The time density curves derived from the reconstructed image set matched well with the flow model used to generate the phantom. Conclusion: Dual-gantry image acquisition and constrained iterative reconstruction algorithm may help to obtain time-density curves of contrast agents in blood flows, which may help differentiate malignant tumors from normal tissues or benign tumors.

60 APPLIED LIFE SCIENCES↗

Clinical Utility of the Modified Segmental Boost Technique for Treatment of the Pelvis and Inguinal Nodes

Purpose: Low-lying pelvic malignancies often require simultaneous radiation to pelvis and inguinal nodes. We previously reported improved homogeneity with the modified segmental boost technique (MSBT) compared to that with traditional methods, using phantom models. Here we report our institutional clinical experience with MSBT. Methods and Materials: MSBT patients from May 2001 to March 2007 were evaluated. Parameters analyzed included isocenter/multileaf collimation shifts, time per fraction (four fields), monitor units (MU)/fraction, femoral doses, maximal dose relative to body mass index, and inguinal node depth. In addition, a dosimetric comparison of the MSBT versus intensity modulated radiation therapy (IMRT) was conducted. Results: Of the 37 MSBT patients identified, 32 were evaluable. Port film adjustments were required in 6% of films. Median values for each analyzed parameter were as follows: MU/fraction, 298 (range, 226-348); delivery time, 4 minutes; inguinal depth, 4.5 cm; volume receiving 45 Gy (V45), 7%; V27.5, 87%; body mass index, 25 (range, 16.0-33.8). Inguinal dose was 100% in all cases; in-field inhomogeneity ranged from 111% to 118%. IMRT resulted in significantly decreased dose to normal tissue but required more time for treatment planning and a higher number of MUs (1,184 vs. 313 MU). Conclusions: In our clinical experience, the mono-isocentric MSBT provides a high degree of accuracy, improved homogeneity compared with traditional techniques, ease of simulation, treatment planning, treatment delivery, and acceptable femoral doses for pelvic/inguinal radiation fields requiring 45 to 50.4 Gy. In addition, the MSBT delivers a relatively uniform dose distribution throughout the treatment volume, despite varying body habitus. Clinical scenarios for the use of MSBT vs. intensity-modulated radiation therapy are discussed. To our knowledge, this is the first study reporting the utility of MSBT in the clinical setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated integration gate selection for Gaussian mixture model pulse shape discrimination

Pulse shapes differ between neutron and gamma particles when measured with detector devices employing pulse shape discriminating (PSD) scintillators. Digitized waveforms can be used in detection systems to perform pulse shape discrimination for this application. Prior Gaussian Mixture Model (GMM) methods require access to the pulse full-waveform. Reducing the waveform to a smaller set of combined samples reduces computational cost while affecting PSD performance. In this work, we develop a method for selecting the best performing combination of integration gates, or contiguous summed segments of the digitized pulse for PSD. The method uses a discrimination score based on the GMM PSD approach. Furthermore, the final selection is performed using Bayesian Optimization. PSD detection results are compared with varying numbers of selected gates on time-of-flight (TOF) data. This method can be used to fully automate the selection of gates in an unsupervised (without ground truth labels) setting.

42 ENGINEERING↗

kHz QUASI-PERIODIC OSCILLATIONS FROM THE 2000 AND 2010 X-RAY TRANSIENTS LOCATED IN THE GLOBULAR CLUSTER TERZAN 5: EXO1745-248 AND IGR J17480-2446

EXO1745-248 is a transient neutron star low-mass X-ray binary located in the globular cluster Terzan 5. It was in outburst in 2000 and displayed during one Rossi X-ray Timing Explorer observation a highly coherent quasi-periodic oscillation (QPO) at frequencies between 670 and 715 Hz. Applying a maximum likelihood method to fit the X-ray power density spectrum, we show that the QPO can be detected on segments as short as T = 48 s. We find that its width is consistent with being constant, while previous analysis based on longer segment duration (200 s) found it variable. If the QPO frequency variations in EXO1745-248 follow a random walk (i.e., the contribution of the drift to the measured width increases like {radical}T), we derive an intrinsic width of {approx}2.3 Hz. This corresponds to an intrinsic quality factor of Q {approx} 297 {+-} 50 at 691 Hz. We also show that Q is consistent with being constant between 2.5 and 25 keV. IGR J17480-2446 is another X-ray transient located in Terzan 5. It is a very interesting object showing accretion-powered pulsations and burst oscillations at 11 Hz. We report on the properties of its kHz QPOs detected between October 18 and October 23, soon after the source had moved from the so-called Atoll state to the Z state. Its QPOs are typical of persistent Z sources; in the sense that they have low Q factors ({approx}30) and low rms amplitudes ({approx}5%). The highest frequency (at 870 Hz), if orbital, sets a lower limit on the inner disk radius of {approx}18.5 km and an upper limit to the dipole moment of the magnetic field {mu} {<=} 5 Multiplication-Sign 10{sup 26} G cm{sup 3}.

79 ASTRONOMY AND ASTROPHYSICS↗

Treatment planning for volumetric modulated arc therapy

Purpose: Volumetric modulated arc therapy (VMAT) is a specific type of intensity-modulated radiation therapy (IMRT) in which the gantry speed, multileaf collimator (MLC) leaf position, and dose rate vary continuously during delivery. A treatment planning system for VMAT is presented. Methods: Arc control points are created uniformly throughout one or more arcs. An iterative least-squares algorithm is used to generate a fluence profile at every control point. The control points are then grouped and all of the control points in a given group are used to approximate the fluence profiles. A direct-aperture optimization is then used to improve the solution, taking into account the allowed range of leaf motion of the MLC. Dose is calculated using a fast convolution algorithm and the motion between control points is approximated by 100 interpolated dose calculation points. The method has been applied to five cases, consisting of lung, rectum, prostate and seminal vesicles, prostate and pelvic lymph nodes, and head and neck. The resulting plans have been compared with segmental (step-and-shoot) IMRT and delivered and verified on an Elekta Synergy to ensure practicality. Results: For the lung, prostate and seminal vesicles, and rectum cases, VMAT provides a plan of similar quality to segmental IMRT but with faster delivery by up to a factor of 4. For the prostate and pelvic nodes and head-and-neck cases, the critical structure doses are reduced with VMAT, both of these cases having a longer delivery time than IMRT. The plans in general verify successfully, although the agreement between planned and measured doses is not very close for the more complex cases, particularly the head-and-neck case. Conclusions: Depending upon the emphasis in the treatment planning, VMAT provides treatment plans which are higher in quality and/or faster to deliver than IMRT. The scheme described has been successfully introduced into clinical use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Monolith Cores from an Engineering Scale Demonstration of a Prospective Cast Stone Process

The primary disposition path of Low Activity Waste (LAW) at the DOE Hanford Site is vitrification. A cementitious waste form is one of the alternatives being considered for the supplemental immobilization of the LAW that will not be treated by the primary vitrification facility. Washington River Protection Solutions (WRPS) has been directed to generate and collect data on cementitious or pozzolanic waste forms such as Cast Stone. This report documents the coring and leach testing of monolithic samples cored from an engineering-scale demonstration (ES Demo) with non-radioactive simulants. The ES Demo was performed at SRNL in October of 2013 using the Scaled Continuous Processing Facility (SCPF) to fill an 8.5 ft. diameter x 3.25 ft. high container with simulated Cast Stone grout. The Cast Stone formulation was chosen from the previous screening tests. Legacy salt solution from previous Hanford salt waste testing was adjusted to correspond to the average LAW composition generated from the Hanford Tank Waste Operation Simulator (HTWOS). The dry blend materials, ordinary portland cement (OPC), Class F fly ash, and ground granulated blast furnace slag (GGBFS or BFS), were obtained from Lafarge North America in Pasco, WA. In 2014 core samples originally obtained approximately six months after filling the ES Demo were tested along with bench scale molded samples that were collected during the original pour. A latter set of core samples were obtained in late March of 2015, eighteen months after completion of the original ES Demo. Core samples were obtained using a 2” diameter x 11” long coring bit. The ES Demo was sampled in three different regions consisting of an outer ring, a middle ring and an inner core zone. Cores from these three lateral zones were further segregated into upper, middle and lower vertical segments. Monolithic core samples were tested using the Environmental Protection Agency (EPA) Method 1315, which is designed to provide mass transfer rates (release rates) of inorganic analytes contained in monolithic material under diffusion controlled release conditions as a function of leaching time. Compressive strength measurements and drying tests were also performed on the 2015 samples. Leachability indices reported are based on analyte concentrations determined from dissolution of the dried samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Catalyzing the Mass Adoption of High Efficiency Technologies in the Multifamily Housing Market

ICAST’s objective was to catalyze the adoption of very-high-efficiency (VHE) heat pump HVAC (mini-splits) and water heaters (HPWH) in multifamily (MF), especially affordable housing (MFAH). Nationally, the market penetration of ENERGY STAR-certified ASHPs is estimated at 43%, and for HPWHs it’s 3% (ENERGY STAR, 2022). Note that mini-splits are a much more practical choice for MF units than ducted systems and their adoption is only a portion of the number provided above, but isolating the market penetration data for mini-split systems is difficult. Both the heat pump-based HVAC and water heater systems can be approx. three times more efficient than their conventional counterparts for space and water heating. While awareness and adoption of VHE heat pumps has been growing nationally, and electric heat pump systems have outsold gas furnaces for two years in a row, the MF segment continues to lag behind single-family. MF constitutes almost a third of the housing in the U.S., so scaling up VHE adoption in this segment can assist in achieving critical climate change goals, while preserving housing affordability for the low-to-moderate income (LMI) population (historically, 85% of residents of MF are LMI).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗