Search NASA⌕ Search

SEARCH · Search NASA

Results for “validation method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89

Hadron-Argon Cross-Section Measurements at Protodune

The Deep Underground Neutrino Experiment (DUNE) is a next-generation experiment designed to measure neutrino oscillations with unprecedented precision, specifically seeking to identify CP violation in the lepton sector. DUNE utilizes the Liquid Argon Time Projection Chamber (LArTPC) as its core detecting technology, offering high-resolution imaging to reconstruct neutrino interactions on argon. A primary challenge in this reconstruction is the modeling of hadronic final-state interactions (FSI), where hadrons produced at the initial interaction vertex undergo further scattering before escaping the nucleus. In this thesis, I utilize the ProtoDUNE-SP detector and its 1~GeV/$c$ hadron beam at the CERN Neutrino Platform to present the first measurements of total inelastic $\pi^+$-argon and proton-argon cross sections in an energy regime critical to DUNE. I detail the development and validation of the ``slicing method'', which utilizes a kiloton-scale LArTPC to extract hadron-argon cross sections. These measurements provide an indispensable benchmark for informing DUNE's FSI modeling, and our results show no significant tension with current model predictions. Additionally, I study the impact of FSI modeling on DUNE’s sensitivity to oscillation parameters. This study demonstrates that variations in FSI models may be degenerate with oscillation features, highlighting the necessity of using direct experimental data to refine interaction models. Finally, I provide an outlook on related studies that will further contribute to this effort, supporting the ambitious physics goals of upcoming neutrino oscillation programs including DUNE.

Yin-Rui, Liu [U. Chicago (main)]↗

Increased fissionable material loading of vitrified borosilicate glass in support of efficient disposition of nuclear materials at Savannah River - 15299

The US DOE is vitrifying liquid HLW, converting it into a glass form suitable for long term storage and disposal. The waste includes fissionable isotopes and, as a consequence, may possess an inadvertent criticality hazard. The technical basis for determining when an inadvertent criticality hazard exists is unclear. ANS criticality safety standards do not provide relevant subcritical safety limits and little experimental data exist to support development of such a limit. As a result, the DOE has implemented a conservative limit of 897 grams of fissile nuclides per cubic meter of glass. However, this limit has the potential to impede efficient disposal of various fissionable materials at the Savannah River Site. Work is being conducted to establish an alternate fissionable material limit which would be less restrictive, but still ensure criticality safety. A series of computer models are constructed and analyzed using a general purpose Monte Carlo N-Particle neutron transport code. First, a baseline model is established and analyzed. Next, numerous variations to the baseline model (i.e., perturbations) are analyzed with the code to understand the impact of the change. Based on the results, it is evident the atomic ratio of B-10 to equivalent Pu-239 would be an effective means to ensure subcriticality of HLW vitrified in a borosilicate glass matrix. The proposed limit, its technical basis, and all necessary application constraints are discussed. This proposed limit is expected to permit significantly higher quantities of fissile nuclides in the vitrified waste form. It will also account for several non-fissile, fissionable nuclides which are expected to add reactivity to the glass waste form. The proposed limit embodies large conservatisms intended to provide assurance of safety in spite of the significant uncertainties associated with its development. The single most important uncertainty arises from the inability to validate the calculations which form its technical basis. While they are done with the latest available nuclear data and well established analytical methods, they are, nonetheless, not validated as required for subcritical safety limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation and Verification of Multi-Material Split Rings

Process induced residual stresses commonly occur in composite structures composed of dissimilar materials. These residual stresses form due to differences in the composite materials coefficients of thermal expansion as well as the shrinkage upon cure exhibited by most thermoset polymer matrix materials. Depending upon the specific geometric details of the composite structure and the materials curing parameters, it is possible that these residual stresses can result in interlaminar delamination and fracture within the composite as well as plastic deformation in the structures metallic materials. It is important to consider potential residual stresses when designing composite parts and their manufacturing processes. However, the experimental determination of residual stresses in prototype parts can be prohibitive, both in terms of financial and temporal costs. As an alternative to physical measurement, it is possible for computational tools to be used to quantify potential residual stresses in composite prototype parts. A simplified method for simulating residual stresses was previously validated with two simple bi-material structures. Continuing on, the objective of this study is to further validate the simplified method for simulating residual stresses for bi-material split rings of different composites and layup variations. The validation process uses uncertainty quantification to develop a distribution of possible simulated residual stress states that are compared to experimentally measured residual stress states of fabricated structures similar to those simulated. The results of the comparisons indicate that the proposed finite element modeling approach is capable of accurately simulating the formation of residual stresses in composite structures and a temperature independent material model is adequate within the composites glassy region.

36 MATERIALS SCIENCE↗

Inversion-based correction of Double-Torsion (DT) subcritical crack growth tests for crack profile geometry

Because of its simplicity and the ability to produce a stable, slow-propagating crack, the Double-Torsion (DT) method has been used widely for investigating the critical and subcritical propagation of a slow-propagating tensile (mode-I) crack. However, to determine the complex relationship between the crack velocity $\mathcal{v_c}$ vs. the strain energy release rate $\mathscr{G}$ (or the stress intensity factor K) from laboratory measurements, several corrections must be made to account for the impact of sample and crack geometry. Particularly, DT test typically produces a crack with a curved edge profile instead of a straight line, causing the local $\mathcal{v_c}$ and $\mathscr{G}$ vary along the crack front. The experimentally measured $\mathcal{v_c}$ and $\mathscr{G}$ data merely reflect collective, averaged behavior of the crack. This makes inversion for the intrinsic, “true” crack growth kinetics necessary, based upon the knowledge of the crack geometry. Simple and effective correction methods have been proposed and validated for the slow, chemical-reaction-controlled part (Region I) of the $\mathcal{v_c}$-$\mathscr{G}$ curve. However, reliable methods for the highly nonlinear, transport-dominated part (Region II) and its sudden transition to the dynamic propagation part (Region III) are still lacking. Here we propose a method for determining the intrinsic $\mathcal{v_c}$-$\mathscr{G}$ relationship across all three Regions based upon DT test data, using a simple model function and its numerical inversion. The performance of this approach is examined and demonstrated using both synthetic and laboratory data for subcritical crack growth in soda lime glass.

42 ENGINEERING↗

TokaMaker: An open-source time-dependent Grad-Shafranov tool for the design and modeling of axisymmetric fusion devices

Here, in this paper, we present a new static and time-dependent MagnetoHydroDynamic (MHD) equilibrium code, TokaMaker, for axisymmetric configurations of magnetized plasmas, based on the well-known Grad-Shafranov equation. This code utilizes finite element methods on an unstructured triangular grid to enable capturing accurate machine geometry and simple mesh generation from engineering-like descriptions of present and future devices. The new code is designed for ease of use without sacrificing capability and speed through a combination of Python, Fortran, and C/C++ components. A detailed description of the numerical methods of the code, including a novel formulation of the boundary conditions for free-boundary equilibria, and validation of the implementation of those methods using both analytic test cases and cross-code validation is shown. Results show expected convergence across tested polynomial degree for analytic and cross-code test cases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental depth dose curves of a 67.5 MeV proton beam for benchmarking and validation of Monte Carlo simulation

Purpose: To measure depth dose curves for a 67.5 ± 0.1 MeV proton beam for benchmarking and validation of Monte Carlo simulation. Methods: Depth dose curves were measured in 2 beam lines. Protons in the raw beam line traversed a Ta scattering foil, 0.1016 or 0.381 mm thick, a secondary emission monitor comprised of thin Al foils, and a thin Kapton exit window. The beam energy and peak width and the composition and density of material traversed by the beam were known with sufficient accuracy to permit benchmark quality measurements. Diodes for charged particle dosimetry from two different manufacturers were used to scan the depth dose curves with 0.003 mm depth reproducibility in a water tank placed 300 mm from the exit window. Depth in water was determined with an uncertainty of 0.15 mm, including the uncertainty in the water equivalent depth of the sensitive volume of the detector. Parallel-plate chambers were used to verify the accuracy of the shape of the Bragg peak and the peak-to-plateau ratio measured with the diodes. The uncertainty in the measured peak-to-plateau ratio was 4%. Depth dose curves were also measured with a diode for a Bragg curve and treatment beam spread out Bragg peak (SOBP) on the beam line used for eye treatment. The measurements were compared to Monte Carlo simulation done with GEANT4 using TOPAS. Results: The 80% dose at the distal side of the Bragg peak for the thinner foil was at 37.47 ± 0.11 mm (average of measurement with diodes from two different manufacturers), compared to the simulated value of 37.20 mm. The 80% dose for the thicker foil was at 35.08 ± 0.15 mm, compared to the simulated value of 34.90 mm. The measured peak-to-plateau ratio was within one standard deviation experimental uncertainty of the simulated result for the thinnest foil and two standard deviations for the thickest foil. It was necessary to include the collimation in the simulation, which had a more pronounced effect on the peak-to-plateau ratio for the thicker foil. The treatment beam, being unfocussed, had a broader Bragg peak than the raw beam. A 1.3 ± 0.1 MeV FWHM peak width in the energy distribution was used in the simulation to match the Bragg peak width. An additional 1.3–2.24 mm of water in the water column was required over the nominal values to match the measured depth penetration. Conclusions: The proton Bragg curve measured for the 0.1016 mm thick Ta foil provided the most accurate benchmark, having a low contribution of proton scatter from upstream of the water tank. The accuracy was 0.15% in measured beam energy and 0.3% in measured depth penetration at the Bragg peak. The depth of the distal edge of the Bragg peak in the simulation fell short of measurement, suggesting that the mean ionization potential of water is 2–5 eV higher than the 78 eV used in the stopping power calculation for the simulation. The eye treatment beam line depth dose curves provide validation of Monte Carlo simulation of a Bragg curve and SOBP with 4%/2 mm accuracy.

60 APPLIED LIFE SCIENCES↗

Active multi-mode data analysis to improve fault diagnosis in AHUs

Faults in heating, ventilation and air conditioning systems can lead to increased energy consumption, occupant comfort issues, and reduced equipment lifetime. Commercial fault detection and diagnosis (FDD) tools has been increasingly deployed in U.S. commercial buildings. While they are helping to achieve energy efficiency and operational reliability, there remain gaps in their fault diagnostic capabilities. The diagnostic results often contain multiple distinct candidate root causes (CRCs) or offer no insight into CRCs. This study developed a novel active rule-based multi-mode data analysis method to enhance diagnostic resolution by applying proven rule sets and additional new rules to data from multiple known operational modes. The proposed method was demonstrated using enhanced air handling unit performance assessment rule sets and validated with the simulated data of two air handling units. New metrics, namely, reduced number of CRCs and improvement ratio, were developed to quantify the improvement of fault diagnostic resolution. The validation results showed that the proposed method effectively reduced the number of CRCs in contrast to analyzing data solely for a single mode of operation. It achieved a median improvement ratio of 80% in 19 test cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power Decoupling Method for Voltage Source Inverters Using Grid Voltage Modulated Direct Power Control in Unbalanced System

The grid voltage modulated direct power control (GVM-DPC) is a novel power regulation method for grid-connected voltage source inverters (VSI). However, interactions between real and reactive powers still exist in GVM-DPC under unbalanced grid voltage condition, which may deteriorate its transient performance. Here, this article proposes a power decoupling method for GVM-DPC-based VSI in unbalanced systems based on the dynamic feedforward power compensation strategy, which can reduce the coupling magnitudes of real and reactive powers in the transient stages. First, the power coupling mechanism of positive and negative sequence real and reactive powers of VSI under the unbalanced voltage condition is analyzed. Then, the power coupling magnitudes (PCM) are derived according to relationships among the positive sequence components of real power, reactive power and point of common coupling (PCC) voltages. Next, the PCM are compensated into the GVM-DPC for the better decoupling performance. Furthermore, a stability analysis of the proposed control system is studied based on the impedance model, and a comparison with the traditional power decoupling method based on virtual impedance is conducted to show the superiority of the proposed method. Finally, simulations, hardware-in-loop test and experiment are conducted to validate the effectiveness of the proposed method.

42 ENGINEERING↗

Theoretical investigation of resonant frequencies of unstrapped magnetron with arbitrary side resonators

In this paper, a sector steps approximation method is proposed to investigate the resonant frequencies of magnetrons with arbitrary side resonators. The arbitrary side resonator is substituted with a series of sector steps, in which the spatial harmonics of electromagnetic field are also considered. By using the method of admittance matching between adjacent steps, as well as field continuity conditions between side resonators and interaction regions, the dispersion equation of magnetron with arbitrary side resonators is derived. Resonant frequencies of magnetrons with five common kinds of side resonators are calculated with sector steps approximation method and computer simulation softwares, in which the results have a good agreement. The relative error is less than 2%, which verifies the validity of sector steps approximation method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Bond Strength of U-Mo Fuel Plates Using the Laser Shockwave Technique: Capabilities and Preliminary Results

This report summarizes work conducted to-date on the implementation of new laser-based capabilities for characterization of bond strength in nuclear fuel plates, and presents preliminary results obtained from fresh fuel studies on as-fabricated monolithic fuel consisting of uranium-10 wt.% molybdenum alloys clad in 6061 aluminum by hot isostatic pressing. Characterization involves application of two complementary experimental methods, laser-shock testing and laser-ultrasonic imaging, collectively referred to as the Laser Shockwave Technique (LST), that allows the integrity, physical properties and interfacial bond strength in fuel plates to be evaluated. Example characterization results are provided, including measurement of layer thicknesses, elastic properties of the constituents, and the location and nature of generated debonds (including kissing bonds). LST provides spatially localized, non-contacting measurements with minimum specimen preparation, and is ideally suited for applications involving radioactive materials, including irradiated materials. The theoretical principles and experimental approaches employed in characterizing nuclear fuel plates are described, and preliminary bond strength measurement results are discussed, with emphasis on demonstrating the capabilities and limitations of these methods. These preliminary results demonstrate the ability to distinguish bond strength variations between different fuel plates. Although additional development work is necessary to validate and qualify the test methods, these results suggest LST is viable as a method to meet fuel qualification requirements to demonstrate acceptable bonding integrity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WINDPROF: Merged Best-Estimate Wind Profile Data – Site A1 (AWAKEN Campaign)

WINDPROF provides 10-minute wind and turbulence profiles, integrating Doppler lidars and anemometers during the AWAKEN campaign. Key data include wind speed, direction, vertical velocity, and turbulence parameters, with standardized quality control (e.g., instrument-specific thresholds and inter-instrument validation). Profiles are interpolated to a height grid (20 m spacing below 100 m; 30 m above) and include uncertainty estimates, offering reproducible methods for atmospheric research, model validation, and wind energy studies.

17 WIND ENERGY↗

WINDPROF: Merged Best-Estimate Wind Profile Data – Site A2 (AWAKEN Campaign)

WINDPROF provides 10-minute wind and turbulence profiles, integrating Doppler lidars and anemometers during the AWAKEN campaign. Key data include wind speed, direction, vertical velocity, and turbulence parameters, with standardized quality control (e.g., instrument-specific thresholds and inter-instrument validation). Profiles are interpolated to a height grid (20 m spacing below 100 m; 30 m above) and include uncertainty estimates, offering reproducible methods for atmospheric research, model validation, and wind energy studies.

17 WIND ENERGY↗

WINDPROF: Merged Best-Estimate Wind Profile Data – Site H (AWAKEN Campaign)

WINDPROF provides 10-minute wind and turbulence profiles, integrating Doppler lidars and anemometers during the AWAKEN campaign. Key data include wind speed, direction, vertical velocity, and turbulence parameters, with standardized quality control (e.g., instrument-specific thresholds and inter-instrument validation). Profiles are interpolated to a height grid (20 m spacing below 100 m; 30 m above) and include uncertainty estimates, offering reproducible methods for atmospheric research, model validation, and wind energy studies.

17 WIND ENERGY↗

Development and Comparison of Purgeable Mercury Values in SRR Samples Measured by SRNL and Eurofins FGS

Savannah River Remediation (SRR) requested the development of mercury speciation capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins Frontier Global Sciences (FGS). This document reports on this method development work as well as the comparative analyses conducted between the two laboratories. Development, optimization, and validation were undertaken at SRNL to produce a method for the species-specific analysis of dissolved gaseous mercury (DGM) in samples from SRR. It was determined that DGM present in SRR samples represented a combination of various soluble and volatile mercury species- and is thus referred to in this document as purgeable mercury. A method has been developed and analytically validated for the analysis of purgeable mercury in caustic nuclear waste. Using multivariate optimization method, purge flow rate was determined to be highly correlated with increased response (p=0.023). Total recovery of spiked purgeable mercury from deionized water was 99.4 ±10.6% and 91.6 ±14.9% from spiked high-activity tank waste samples. Calibration, by external calibration and standard addition calibration, maintained a mean accuracy of 101 ±5% and 99.9 ±1.7%, respectively. This method represents a decrease in sample handling and processing over currently standard methods and represents a more amenable method for purgeable mercury analysis in liquid nuclear waste.1 An interlaboratory comparison was performed between SRNL and Eurofins FGS in the co-analysis of three quarterly Tank 50 samples. Two samples demonstrated no statistically significant difference (p=0.271, p=0.0811), with one sample biased 30% low to a statistically significant degree (p=0.0432). Large mean uncertainty was present in the results reported by both laboratories (±15% and 40% from SRNL and Eurofins), with no significant difference observed in uncertainty (p=0.934). Across all co-analyzed samples, no significantly difference was observed in precision (p=0.205) or reported values (p=0.352) between SRNL and Eurofins. These results indicate that SRNL-AD may provide data to the customer of statistically similar quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model-based PSF and MTF estimation and validation from skeletal clinical CT images

Purpose: A method was developed to correct for systematic errors in estimating the thickness of thin bones due to image blurring in CT images using bone interfaces to estimate the point-spread-function (PSF). This study validates the accuracy of the PSFs estimated using said method from various clinical CT images featuring cortical bones. Methods: Gaussian PSFs, characterized by a different extent in the z (scan) direction than in the x and y directions were obtained using our method from 11 clinical CT scans of a cadaveric craniofacial skeleton. These PSFs were estimated for multiple combinations of scanning parameters and reconstruction methods. The actual PSF for each scan setting was measured using the slanted-slit technique within the image slice plane and the longitudinal axis. The Gaussian PSF and the corresponding modulation transfer function (MTF) are compared against the actual PSF and MTF for validation. Results: The differences (errors) between the actual and estimated full-width half-max (FWHM) of the PSFs were 0.09 ± 0.05 and 0.14 ± 0.11 mm for the xy and z axes, respectively. The overall errors in the predicted frequencies measured at 75%, 50%, 25%, 10%, and 5% MTF levels were 0.06 ± 0.07 and 0.06 ± 0.04 cycles/mm for the xy and z axes, respectively. The accuracy of the estimates was dependent on whether they were reconstructed with a standard kernel (Toshiba's FC68, mean error of 0.06 ± 0.05 mm, MTF mean error 0.02 ± 0.02 cycles/mm) or a high resolution bone kernel (Toshiba's FC81, PSF FWHM error 0.12 ± 0.03 mm, MTF mean error 0.09 ± 0.08 cycles/mm). Conclusions: The method is accurate in 3D for an image reconstructed using a standard reconstruction kernel, which conforms to the Gaussian PSF assumption but less accurate when using a high resolution bone kernel. The method is a practical and self-contained means of estimating the PSF in clinical CT images featuring cortical bones, without the need phantoms or any prior knowledge about the scanner-specific parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Voltage equilibration for reactive atomistic simulations of electrochemical processes

We introduce electrochemical dynamics with implicit degrees of freedom (EChemDID), a model to describe electrochemical driving force in reactive molecular dynamics simulations. The method describes the equilibration of external electrochemical potentials (voltage) within metallic structures and their effect on the self-consistent partial atomic charges used in reactive molecular dynamics. An additional variable assigned to each atom denotes the local potential in its vicinity and we use fictitious, but computationally convenient, dynamics to describe its equilibration within connected metallic structures on-the-fly during the molecular dynamics simulation. This local electrostatic potential is used to dynamically modify the atomic electronegativities used to compute partial atomic changes via charge equilibration. Validation tests show that the method provides an accurate description of the electric fields generated by the applied voltage and the driving force for electrochemical reactions. We demonstrate EChemDID via simulations of the operation of electrochemical metallization cells. The simulations predict the switching of the device between a high-resistance to a low-resistance state as a conductive metallic bridge is formed and resistive currents that can be compared with experimental measurements. In addition to applications in nanoelectronics, EChemDID could be useful to model electrochemical energy conversion devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Glycolate in Radioactive Waste by Ion Chromatography (IC) and Proton Nuclear Magnetic Resonance (H NMR)

Here, in preparation for implementing the Nitric-Glycolic (NG) acid flowsheet for the Savannah River Site (SRS) Liquid Waste System (LWS), analytical methods for determining glycolate at low concentration, below 20 mg/L in radioactive samples, were developed to support system management and safety. To accommodate the wide range of LWS matrix conditions, two alternative methods were developed, refined, and demonstrated for glycolate analysis in radioactive waste samples: ion chromatography (IC) and a proton nuclear magnetic resonance (H NMR). Investigators validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. The deployed IC method is applicable in low to moderate ionic strength samples and requires sample pretreatment using a Dionex OnGuard II H + cartridge. The deployed H NMR method is more labor intensive but provides options for a broader range of matrices. Based on the results, high quality glycolate analysis of the Defense Waste Processing Facility (DWPF) condensate in Tank 22 is feasible by IC down to approximately 12 mg/L. Using H NMR, glycolate may be determined to 8 mg/L or lower depending on the run time with the potential for broader applicability of the method to higher ionic strength conditions in other tanks of the SRS LWS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗