Search NASASearch

SEARCH · Search NASA

Results for “.NET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Seasonality and Albedo Dependence of Cloud Radiative Forcing in the Upper Colorado River Basin

Mountains create and enhance their own clouds, which both scatter and absorb shortwave radiation from the sun and absorb and re-emit land surface and atmospheric longwave radiation. However, the impacts of clouds on the surface radiation balance in high elevation snowy mountain terrain are poorly explored. In this study, we use data collected by the SAIL field campaign and partner organizations in the upper elevations (2,880 m.a.s.l) of the Upper Colorado River Basin (UCRB) over a 21-month period from September 2021 to June 2023 to estimate Cloud Radiative Forcing (CRF) in the shortwave, longwave, and the net effect. Longwave warming effects dominate during the winter when snow albedos are high (0.8–0.9) and the background atmospheric precipitable water vapor is low (<0.5 cm), yielding a maximum monthly average net CRF of +34.7 W·m -2 , meaning that clouds increase the net radiation relative to clear skies during this time period. The sign of net CRF switches in the warm season as snow recedes, sun-angles increase, and the North American monsoon arrives, yielding a minimum monthly average net CRF of -47.6 W·m -2 with hourly minima of -600 W·m -2 . The sign of net CRF is typically positive, even at solar noon, when the surface is snow covered, except for a brief period over melting, low-albedo snow (0.5–0.6) impacted by dust impurities. Sensitivity tests elucidate the role of the surface albedo on the net CRF. The results suggest that net CRF will increase in magnitude and lead to a more persistent cooling effect on the surface net radiation budget as the snow cover declines.

54 ENVIRONMENTAL SCIENCES

Quantifying the impacts of atmospheric rivers on the surface energy budget of the Arctic based on reanalysis

We present a comprehensive analysis of Arctic surface energy budget (SEB) components during atmospheric river (AR) events identified by integrated water vapor transport exceeding the monthly 85th-percentile climatological threshold in 3-hourly ERA5 reanalysis data from January 1980 to December 2019. Analysis of average anomalies in SEB components, net SEB, and the overall AR contribution to both the seasonal SEB components and net SEB climatology reveals clear seasonality and distinct land–sea–sea ice contrast patterns. Over the sea-ice-covered central Arctic Ocean, ARs significantly impact net SEB, inducing substantial surface warming in fall, winter, and spring. This warming is primarily driven by large anomalies in surface downward longwave radiation (LWD), which average 29–45 W m −2 during the cold seasons. In contrast, AR-related LWD anomalies are smaller in summer, averaging around 15 W m −2 , indicating a reduced impact during this season. Over sub-polar oceans, ARs have the most substantial positive impact on net SEB in cold seasons, mainly attributed to significant positive turbulent heat flux anomalies. AR-related turbulent heat anomalies reduce the upward turbulent flux, contributing up to −11 % relative to its seasonal climatology. In summer, ARs induce negative impacts on net SEB, primarily due to reduced shortwave radiation from increased cloud cover during AR events. Over continents, ARs generate smaller absolute impacts on net SEB because the large LWD anomalies are largely offset by corresponding increases in upward longwave radiation, particularly during cold seasons. Additionally, the seemingly large relative contributions of ARs to the net SEB over land primarily reflects the small magnitude of the climatological net SEB over continents. Greenland, especially western Greenland, exhibits significant downward longwave radiation anomalies associated with ARs, which drive large net SEB anomalies and contribute >54 % to mean SEB and induce amplified surface warming year-round. This holds significance for melt events, particularly during summer. Additionally, results of AR-related SEB impacts strongly depend on detection methods, as restrictive AR detection algorithms that emphasize extreme AR events, with large AR-related anomalies, do not necessarily indicate a large overall contribution to the SEB climatology due to the low occurrence frequency of these events. This study quantifies the role of ARs in the surface energy budget, contributing to our understanding of the Arctic warming and sea ice decline in ongoing Arctic amplification.

Arctic Sea ice change

Techno-economic assessment of residential PV system tariff policies in Jordan

This study assesses the economic and technical performance of four energy policy scenarios for Jordan's residential photovoltaic (PV) systems: net metering, net billing, zero-export with battery storage, and sell-all-buy-all. With the recent introduction of time-of-use (TOU) tariffs and policies addressing the “duck curve” effect, the research focuses on optimizing PV system sizing across different regulatory frameworks. A detailed techno-economic analysis evaluates these scenarios based on energy production, cost savings, payback periods, and energy self-sufficiency. The findings indicate that net metering and net billing offer the highest cost savings and the shortest payback periods (∼3 years). While the zero-export strategy with battery storage enhances energy self-sufficiency by up to 70%, it requires a higher upfront investment. The sell-all-buy-all scenario supports larger system sizes, achieving a low levelized cost of electricity (0.0696 USD/kWh) and a net present value of 619 USD. Additionally, the study identifies a critical feed-in tariff threshold of 0.055 USD/kWh, at which net billing becomes as financially attractive as net metering. Here, these insights offer valuable recommendations for policymakers to optimize net billing rates and TOU tariffs, promoting the expansion of Jordan's renewable energy sector.

Battery storage

Soil nitrogen mineralization rates, nutrient stocks, stable isotopes, and water volumetric measurements across terrestrial-aquatic interfaces from three wetlands at the Tanglewood Biological Station, Alabama

This dataset supports a broader study investigating wetland hydrologic and biogeochemical responses to inundation events. Soil samples were collected across four sampling events along terrestrial-aquatic gradients at three wetland sites located within the Tanglewood Biological Station in Alabama from April 2024 to June 2025. The contents in this data package include soil in-situ nitrogen mineralization rates (measurements of net nitrification, net ammonification, and net mineralization), nutrient stocks (total carbon, total nitrogen, and organic matter), stable isotopes (carbon and nitrogen), and water volumetric measurements (water-filled pore space). Water level data related to each wetland location can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/2530253 (Kirker et al., 2024), related water geochemistry data can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3001967 (Forbes et al., 2025), and related surface water sediment chemistry data can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3377325 (Molina Serpas et al., 2026). In addition to this readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) file-level metadata; (2) data dictionary; (3) field metadata and international generic sample numbers (IGSNs); (4) readme; (5) the field protocol; and (6) a subfolder with sample data. The sample data subfolder contains (1) net nitrification rate, (2) net ammonification rate, (3) areal net mineralization rate, (4) percent organic matter, (5) water-filled pore space, (6) total carbon content, (7) total nitrogen content, (8) stable carbon isotope (delta carbon-13), and (9) stable nitrogen isotope (delta nitrogen-15), and (10) methods codes. All files are .csv or .pdf.

13-C

Greenhouse gas emissions reduction strategies that maximize portfolio-wide life cycle cost reduction, resilience, and environmental justice benefits

While strategies to achieve net-zero emissions at an individual site are well understood, new analysis methods are required for organizations seeking to achieve net-zero across multiple facilities, each with concurrent priority goals. At a portfolio level, distinct locations present varied challenges that cannot be addressed through singular solutions, and competing goals can take precedence with the assumption that net-zero emissions strategies deter from energy resilience and cost savings, therefore negatively impacting nearby communities. This study tests these assumptions by analyzing 16 diverse sites (varying in size, climate, and energy use) to identify strategies that reduce emissions and assess the impact these strategies have on life cycle costs, resilience, and communities with environmental justice concerns. Methods were developed to approximate missing information essential to net-zero evaluation. Established methods were augmented to evaluate life cycle costs, resilience, and environmental justice impacts across a set of strategies and accommodate the multi-criteria analyses. Potential benefits from identified strategies were quantified using site characteristics and a set of corresponding metrics. The net-zero analysis found that 11 sites could use on-site strategies to eliminate all but 2% of emissions generated. The remaining emissions can be offset, for instance through sequestration, executed at the portfolio scale. On-site carbon-free energy was found to reduce 51% of emissions across all sites; efficiency reduced 19% of emissions; sequestration 16%; procured carbon-free energy 15%; fuel switching 1.6%; and fleet electrification 1.3%. Building electrification, however, increased emissions by 4.4%. Different strategies also provide cost, resilience, and/or environmental justice benefits—the degree to which varies with individual site conditions. The findings indicate an advantage to considering the strategies as a comprehensive set, which leads to co-benefits, both in the ability to achieve net-zero goals and in advancing other goals. The results present the case for comprehensive advanced planning at the portfolio level to prioritize investments that will balance the minimization of emissions and life cycle cost with the maximization of resilience and environmental justice benefits. The novel methods for evaluation and integration, valuation of benefits, and consideration at the portfolio scale allow organizations to select investments that simultaneously address multiple key priorities.

Net-Zero Emissions

Concurrent Measurement of O 2 Production and Isoprene Emission During Photosynthesis: Pros, Cons and Metabolic Implications of Responses to Light, CO 2 and Temperature

Traditional leaf gas exchange experiments have focused on net CO 2 exchange (A net ). Here, using California poplar (Populus trichocarpa), we coupled measurements of net oxygen production (NOP), isoprene emissions and δ 18 O in O 2 to traditional CO 2 /H 2 O gas exchange with chlorophyll fluorescence, and measured light, CO 2 and temperature response curves. This allowed us to obtain a comprehensive picture of the photosynthetic redox budget including electron transport rate (ETR) and estimates of the mean assimilatory quotient (AQ = A net /NOP). We found that A net and NOP were linearly correlated across environmental gradients with similar observed AQ values during light (1.25 ± 0.05) and CO 2 responses (1.23 ± 0.07). In contrast, AQ was suppressed during leaf temperature responses in the light (0.87 ± 0.28), potentially due to the acceleration of alternative ETR sinks like lipid synthesis. A net and NOP had an optimum temperature (Topt) of 31°C, while ETR and δ 18 O in O2 (35°C) and isoprene emissions (39°C) had distinctly higher T opt . The results confirm a tight connection between water oxidation and ETR and support a view of light-dependent lipid synthesis primarily driven by photosynthetic ATP/NADPH not consumed by the Calvin–Benson cycle, as an important thermotolerance mechanism linked with high rates of (photo)respiration and CO 2 /O 2 recycling.

H218O labelling

Enhanced pedestal transport driven by edge collisionality on Alcator C-Mod and its role in regulating H-mode pedestal gradients

Experimental measurements of plasma and neutral profiles across the pedestal are used in conjunction with 2D edge modeling to examine pedestal stiffness in Alcator C-Mod H-mode plasmas. Enhanced D α experiments on Alcator C-Mod observed pedestal degradation and loss in confinement below a critical value of net power crossing the separatrix, P net = $P^{crit}_{net}$ ≈ 2.3 MW, in the absence of any external fueling. New analysis of ionization and particle flux profiles reveal saturation of the pedestal electron density, $n^{ped}_{e}$, despite continuous increases in ionization throughout the pedestal, inversely related to P net . A limi to the pedestal $\nabla$n e emerges as the particle flux, Γ D , continues to grow, implying increases in the effective particle diffusivity, D eff . This is well-correlated with the separatrix collisionality, $v^*_{sep}$ and a turbulence control parameter, α t , implying a possible transition in type of turbulence. The transition is well correlated with the experimentally observed value of $P^{crit}_{net}$. SOLPS-ITER modeling is performed for select discharges from the power scan, constrained with experimental electron and neutral densities, measured at the outer midpane. The modeling confirms general growth in D eff , consistent with experimental findings, and additionally suggests even larger growth in Χ e at the same $P^{crit}_{net}$.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Pyrolyzer Assisted Vapor Transport Deposition of Antimony-Doped Cadmium Telluride

In this study, we developed a new method for in situ Sb doping of CdTe thin films combining vapor transport deposition with a Group V pyrolyzer to address Sb doping concentration and doping efficiency. The Sb doped CdSeTe (CdSeTe:Sb) films were deposited in solar cell structures under variations of Sb dopant source heater, vapor pyrolyzer temperature, and Cd vapor excess. Results indicate that although these parameters do not affect the CdTe morphology or crystal structure, they critically influence doping efficiency and trap concentration. Capacitance-voltage measurements show that a higher dopant heater (TD) or pyrolyzer (TP) temperature leads to higher net carrier concentration, achieving a net carrier concentration of 1016 cm-3 and 20% doping efficiency with a TD/TP combination of 600 degrees C/1100 degrees C. By tuning the Cd/Sb flux ratio during CdSeTe:Sb deposition, the lowest defect concentration is achieved at Cd/Sb of 1.4:1, which produced the best VOC CdSeTe:Sb cell. This demonstrates a path to produce high net carrier concentration polycrystalline CdTe thin film with a low concentration of dopant-induced defects.

14 SOLAR ENERGY

Nitrogen Deposition Weakens Soil Carbon Control of Nitrogen Dynamics Across the Contiguous United States

ABSTRACT Anthropogenic nitrogen (N) deposition is unequally distributed across space and time, with inputs to terrestrial ecosystems impacted by industry regulations and variations in human activity. Soil carbon (C) content normally controls the fraction of mineralized N that is nitrified ( ƒ nitrified ), affecting N bioavailability for plants and microbes. However, it is unknown whether N deposition has modified the relationships among soil C, net N mineralization, and net nitrification. To test whether N deposition alters the relationship between soil C and net N transformations, we collected soils from coniferous and deciduous forests, grasslands, and residential yards in 14 regions across the contiguous United States that vary in N deposition rates. We quantified rates of net nitrification and N mineralization, soil chemistry (soil C, N, and pH), and microbial biomass and function (as beta‐glucosidase (BG) and N ‐acetylglucosaminidase (NAG) activity) across these regions. Following expectations, soil C was a driver of ƒ nitrified across regions, whereby increasing soil C resulted in a decline in net nitrification and ƒ nitrified . The ƒ nitrified value increased with lower microbial enzymatic investment in N acquisition (increasing BG:NAG ratio) and lower active microbial biomass, providing some evidence that heterotrophic microbial N demand controls the ammonium pool for nitrifiers. However, higher total N deposition increased ƒ nitrified , including for high soil C sites predicted to have low ƒ nitrified , which decreased the role of soil C as a predictor of ƒ nitrified . Notably, the drop in contemporary atmospheric N deposition rates during the 2020 COVID‐19 pandemic did not weaken the effect of N deposition on relationships between soil C and ƒ nitrified . Our results suggest that N deposition can disrupt the relationship between soil C and net N transformations, with this change potentially explained by weaker microbial competition for N. Therefore, past N inputs and soil C should be used together to predict N dynamics across terrestrial ecosystems.

Nieland, Matthew A. [Stockbridge School of Agricul

Life Cycle Greenhouse Gas Emissions of Coal-Biomass Co-Firing Power Plants with Carbon Capture and Storage

The United States has set a target to achieve the net-zero economy by 2050. Bioenergy with Carbon Capture and Sequestration (BECCS) is one of the promising negative-emission routes in the mitigation portfolio to help meet this goal. Coal-biomass co-firing with carbon capture and storage (CCS) is a key BECCS technology to realize the carbon mitigation at fossil-fuel power plants. The mitigation potential of co-firing option is affected by numerous critical factors, such as biomass properties, co-firing level, and carbon capture rate. The objectives of the study are to characterize and estimate the life cycle greenhouse gas (GHG) emissions and performance of coal-biomass co-firing power plants with CCS, determine the breakeven co-firing level at power plants necessary to achieve net-zero life cycle emissions, and quantify the variabilities and uncertainties in life cycle emissions. The scope of the life cycle assessment includes the fuel supply, combustion-based power generation, and CO2 transport and storage. A fuel-based life cycle module is developed and embedded in the Integrated Environmental Control Model (IECM), a fossil-fuel power plant modeling tool. This study then applies the enhanced IECM to conduct the process-based life cycle assessment for an array of biomass co-firing scenarios. Deterministic analysis indicates that reaching net-zero life cycle emissions in a biomass co-firing plant without CCS deployment is challenging. Combining biomass co-firing and CCS deployment can significantly lower the overall life cycle emissions of power plants. Net-zero life cycle emissions can be achieved with a 20 wt.% co-firing level and 90% CCS when the Powder River Basin coal is co-fired with energy crops or forestry residues. However, the breakeven co-firing level for net-zero emissions depend on the selected fuel properties. Fuel supply and plant operation are the critical stages influencing the life cycle emissions of power plants with 90% CCS. Deployment of deep CCS beyond 90% CO2 capture can remarkably reduce operational emissions and the breakeven co-firing level. With 99% CCS, the breakeven co-firing rate can be reduced to 12% on average. These findings highlight the trade-offs between technical performance and environmental impact of biomass co-firing at coal-fired power plants and emphasize the role of deep CCS in achieving a net-zero emissions future.

Wu, Wanying

Mechanical suppression of invasive Northern Pike in Box Canyon Reservoir, Washington

Abstract Objective Northern Pike Esox lucius recently invaded Box Canyon Reservoir, Washington, expanding to over 10,000 individuals by 2011. To limit further impacts, a significant reduction in population abundance was required. Project objectives were to reduce relative abundance (catch per unit effort [CPUE]) to less than 1.7 Northern Pike/net (87% reduction) in the core area and to less than 0.5 Northern Pike/net in the northern reservoir section within 3 years and then maintain those abundance targets thereafter. Methods Using gill nets, we conducted intensive annual (2012–2018) suppression each spring, focusing on spawning aggregations in shallow (<2-m), flooded habitats. To evaluate CPUE, a standardized spring pike index netting (SPIN) survey was conducted annually in May and compared to suppression netting CPUE. Result In total, 17,464 Northern Pike were removed in 4868 net sets, with 92.9% captured in the first 3 years, limiting future recruitment. Mean SPIN CPUE in the core area declined from a presuppression (2011) high of 13.2 Northern Pike/net to less than 1.0 Northern Pike/net by 2014. Effort was reduced by up to 80% as the project transitioned from the initial suppression phase (2012–2014) to a control phase (2015–2018), which explored the minimum effort required to maintain abundance targets. A significant rebound in CPUE occurred from 2017 to 2018, indicating that over 267 net sets annually may be required for long-term control. Although the mean CPUE (±95% confidence interval) increased slightly in 2018 (0.6 ± 0.5 Northern Pike/net), the target abundance in the core area was achieved annually from 2013 to 2018. Changes in suppression CPUE reflected those observed in SPIN surveys, further validating the survey and corroborating abundance trends. Conclusion Results demonstrate that the suppression of Northern Pike in large, complex waters is feasible but requires a substantial long-term commitment. We expect the suppression of this invasive species to become standard practice outside of its native range. The methodology and equipment described here could be applied directly or modified by others to suppress Northern Pike.

Bean, Nicholas J.

Impact of Sugarcane Cultivation on C Cycling in Southeastern United States Following Conversion From Grazed Pastures

ABSTRACT The expansion of sugarcane, a tropical high‐yielding feedstock, will likely reshape the Southeastern United States (SE US) bioenergy landscape. However, the sustainability of sugarcane, particularly as it displaces grazed pastures, is highly uncertain. Here, we investigated how pasture conversion to sugarcane in subtropical Florida impacts net ecosystem CO 2 exchange (NEE) and net ecosystem carbon (C) balance (NECB). Measurements were made over three full growth cycles (> 3 years) in sugarcane—plant cane, PC; first ratoon cane, FRC; second ratoon cane, SRC—and in improved (IM) and semi‐native (SN) pastures, which make up ca. 37% of agricultural land in the region. Immediately following conversion, PC was a stronger net source of CO 2 than pastures, indicating the importance of CO 2 losses related to land disturbance. Sugarcane, however, shifted to a strong net sink of CO 2 after first regrowth, and overall sugarcane was a stronger net CO 2 sink than pastures. Both stand age and low water availability during cane emergence and tillering substantially decreased its potential gross CO 2 uptake. Accounting for all C gains and removals (i.e., NECB), greater frequency of burn events and repeated harvest increased removals and overall made sugarcane a stronger C source relative to pastures despite substantial C inputs from the previous land use and a stronger CO 2 sink strength. Time since conversion substantially reduced C losses from sugarcane, and the NECB of SRC was similar to that of IM pasture but lower than that of SN pasture, indicating a rapid shift in the NECB of cane. We conclude that the C‐balance implications following conversion will depend on the proportion of IM versus SN pastures converted to sugarcane. Furthermore, our findings suggest that no‐burn harvest management strategies will be critical to the development of a sustainable bioenergy landscape in SE US.

Gomez‐Casanovas, Nuria

The path to 2060: Saudi Arabia's long-term pathway for GHG emission reduction

Saudi Arabia, as part of its Saudi Green Initiative, has announced its goal to achieve net zero green-house gas emissions by 2060. This ambitious target underscores the nation's dedication to address-ing climate change. However, there is a significant gap in comprehensive analysis regarding the long-term effects of Saudi Arabia's climate policies and their collective contribution towards the net-zero objective. This study endeavors to bridge this gap through a detailed examination using the GCAM-KSA, a specialized version of the Global Change Analysis Model tailored for Saudi Arabia, employing a multi-sectoral methodology that integrates economic, energy, and land use systems within a coherent framework to assess the impact of climate policies on GHG emissions. Our anal-ysis reveals that reaching net-zero GHG emissions by 2060 is a complex challenge requiring con-certed efforts across all sectors of the economy. While transitioning to low-carbon electricity and improving energy efficiency offer considerable emission reductions, fully decarbonizing the indus-trial and transportation sectors poses a significant hurdle. Our findings suggest that Saudi Arabia must triple its emission reduction commitments in its next Nationally Determined Contributions (NDCs) update to align with its 2060 net-zero goal. Early action and increased ambition could avoid the chances of getting locked into the high emission assets and give enough time to transform the energy system. Furthermore, the adoption and integration of Carbon Dioxide Removal (CDR) tech-nologies are identified as crucial for offsetting residual emissions, especially in sectors that might continue to rely on fossil fuels.

29 ENERGY PLANNING, POLICY, AND ECONOMY

A Distributionally Robust Optimization Framework for Stochastic Assessment of Power System Flexibility in Economic Dispatch

Given the complexity of power systems, particularly the high-dimensional variability of net loads, accurately depicting the entire operational range of net loads poses a challenge. To address this, recent methodologies have sought to gauge the maximum range of net load uncertainty across all buses. In this paper, we consider the stochastic nature of the net load and introduce a distributionally robust optimization framework that assesses system flexibility stochastically, accommodating a minimal extent of system violations. We verify the proposed method by solving the flexibility of the economic dispatch problem on four distinct IEEE standard test systems. Compared to traditional deterministic flexibility evaluations, our approach consistently yields less conservative flexibility outcomes.

distributionally robust optimization

Meteorological Conditions in Urban Sites in Knoxville, USA. 2023

This 2023 dataset, which contains four csv files, reports hourly air temperature, wind speed, solar radiation, incident short wave, reflected short wave, incident long wave, emitted long wave, net radiation, and photosynthetically active radiation (PAR) data measured in urban parks in Knoxville, Tennessee, USA. The sites include Cumberland Estates Park (CEP), Socially Equal Energy Efficient Development (SEEED), West Hills (WHP), and Victor Ashe Park (VAP). Air temperature, wind speed and direction, and solar radiation data were obtained from a METER ATMOS 41 All-in-One Weather Station (Pullman, Washington, USA). Incident and emitted radiation (shortwave and longwave) measurements were made using an Apogee (Logan, Utah, USA) net radiometer (Model SN-500-SS). The SQ-521 Full-Spectrum Quantum sensor (Apogee Instruments, Inc) recorded the PAR. The measurement data for CEP, SEEED, and VAP started on July 1, 2023, while WHP started on August 26, 2023. All measurement ended on December 31, 2023. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

Salvador, Christian [ORNL] (ORCID:0000000283287777