Search NASA⌕ Search

SEARCH · Search NASA

Results for “100%”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Endurance Exercise Performance Is Reduced after 6-h Dives at 1.35 ATA When Breathing 100% Oxygen Compared with Air

ABSTRACT Introduction Long-duration dives on consecutive days reduces muscular performance, potentially affecting military personnel. However, a paucity of data exists on how breathing gases affect endurance performance. This study examined the influence of long-duration diving with different breathing gases on aerobic endurance and handgrip performance. Methods Twenty-three military divers completed a single 6-h dive (single dive [SD]) and five 6-h dives over consecutive days (dive week [DW]) with 30-min cycling intervals using air (AIR,n= 13) or 100% oxygen (OXY,n= 10). Before and after SD and DW, subjects completed a maximum handgrip strength test, a handgrip endurance test at 40% maximal strength, and a time to exhaustion run. Results Handgrip endurance decreased after DW in OXY (SD, 1.9 ± 0.0 vs 1.4 ± 0.3 min) compared with AIR (1.8 ± 0.0 vs 1.8 ± 0.2 min) (P< 0.001). Run time decreased after SD (Pre, 20.7 ± 10.4 min; Post, 16.6 ± 7.6 min;P= 0.039) and DW (Pre, 21.6 ± 9.0 min; Post, 11.2 ± 4.0 min;P< 0.001) in OXY and after overall diving in AIR (Pre, 26.5 ± 10.2 min; Post, 22.3 ± 7.5 min;P= 0.025). V̇O 2 decreased after diving only in AIR (Pre, 42.6 ± 3.4 mL·kg −1 ⋅min −1 ; Post, 40.4 ± 3.7 mL·kg −1 ⋅min −1 ;P= 0.010). There were no other significant effects. Conclusions Breathing 100% oxygen during long-duration dives on consecutive days may exacerbate decreases in aerobic endurance and impairs handgrip endurance compared with air. Additional research is needed to elucidate mechanisms of action and possible mitigation strategies.

Sport Sciences↗

Achieving 100 GW idler pulses from an existing petawatt optical parametric chirped pulse amplifier

Optical parametric chirped-pulse-amplification produces two broadband pulses, a signal and an idler, that can both provide peak powers >100 GW. In most cases the signal is used, but compressing the longer-wavelength idler opens up opportunities for experiments where the driving laser wavelength is a key parameter. This paper will describe several subsystems that were added to a petawatt class, Multi-Terawatt optical parametric amplifier line (MTW-OPAL) at the Laboratory for Laser Energetics to address two long-standing issues introduced by the use of the idler, angular dispersion, and spectral phase reversal. To the best of our knowledge, this is the first time that compensation of angular dispersion and phase reversal has been achieved in a single system and results in a 100 GW, 120-fs duration, pulse at 1170 nm.

47 OTHER INSTRUMENTATION↗

A 100 kW 1.3 GHz Magnetron System with Amplitude and Phase Control

Calabazas Creek Research, Inc., Fermilab, and Communications & Power Industries, LLC, developed a 100 kW peak, 10 kW average, 1.3 GHz, magnetron-based, RF system for driving accelerators. Efficiency varied between 81% and 87%. Phase locking uses a novel approach that provides fast amplitude and phase control when coupled into a superconducting accelerator cavity [1]. The system was successfully tested at Fermilab and produced 100 kW in 1.5 ms pulses at a repetition rate of 2 pps. A locking bandwidth of 0.9 MHz was achieved with a drive signal of 269 W injected through a 4 port circulator. The phase locking signal was 25 dB below the magnetron output power. The spectrum of the phase locked magnetron was suitable for driving accelerator cavities. Phase modulation was demonstrated to 50 kHz (the limit of the available driver source). The average power was limited by available conditioning time. Scaling indicates 42 kW of average power should be achievable. Estimated cost is less than $1/Watt of delivered RF power, exclusive of power supplies or modulators. System design and performance measurements will be presented.

43 PARTICLE ACCELERATORS↗

Evaluation of a Potential Groundwater Tracer Test in the Ringold Upper Mud Aquifer at the 100-H Area of the Hanford Site

This document presents an evaluation of a potential groundwater tracer test in the uppermost RUM (Ringold Formation member of Wooded Island – upper mud unit) aquifer in the 100-H Area of the Hanford Site. The results from field electrical resistivity tomography (ERT) investigations, numerical flow and transport (F&T) modeling, coupled ERT-F&T model simulations, and laboratory resin experiments provide the technical basis for evaluating tracer test scenarios that minimize impacts to the 100-HX pump and treat (HX P&T) operations, and maximize hydrologic data acquisitions including the use of advanced surface geophysical techniques for monitoring tracer transport.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100): Six-Month Progress Update [Slides]

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050, along with realizing interim goals of 40% by 2025, 60% by 2040, the phase-out of coal-fired generation by 2028, and a 30% improvement in energy efficiency by 2040, as established in Puerto Rico Energy Public Policy Act (Act 17). Since hurricanes Irma and Maria in September 2017, DOE and its national laboratories have provided Puerto Rico energy system stakeholders with tools, training, and modeling support to enable planning and operation of the electric power grid with more resilience against further disruptions. On February 2, 2022, DOE, FEMA, and six national laboratories launched the two-year Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) to conduct comprehensive analysis of stakeholder-driven pathways to Puerto Rico's energy future. The robust and objective energy analysis entails five activities, with an emphasis on power system reliability, resilience, and generation planning. This presentation provides a six-month progress update on the study, including presentation of four initial scenario frameworks defined with extensive stakeholder input.

14 SOLAR ENERGY↗

Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) (Six-Month Progress Update) [Slides]

Puerto Rico has committed to meeting its electricity needs with 100% renewable energy by 2050, along with realizing interim goals of 40% by 2025, 60% by 2040, the phase-out of coal-fired generation by 2028, and a 30% improvement in energy efficiency by 2040, as established in Puerto Rico Energy Public Policy Act (Act 17). Since hurricanes Irma and Maria in September 2017, DOE and its national laboratories have provided Puerto Rico energy system stakeholders with tools, training, and modeling support to enable planning and operation of the electric power grid with more resilience against further disruptions. On February 2, 2022, DOE, FEMA, and six national laboratories launched the two-year Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) to conduct comprehensive analysis of stakeholder-driven pathways to Puerto Rico's energy future. The robust and objective energy analysis entails five activities, with an emphasis on power system reliability, resilience, and generation planning. This presentation was delivered in a public webinar on July 21, 2022, providing a high level summary of the progress in the first six months of the study, including presentation of four initial scenario definitions based on extensive stakeholder input.

14 SOLAR ENERGY↗

Estudio de Resiliencia de la Red Electrica de Puerto Rico y Transiciones a Energia 100% Renovable (PR100): Actualizacion de Progreso de Seis Meses [Slides]

Puerto Rico se ha comprometido a satisfacer sus necesidades de electricidad con un 100% de energia renovable para 2050, junto con el cumplimiento de objetivos intermedios del 40% para 2025, el 60% para 2040, la eliminacion gradual de la generacion a base de carbon para 2028, y una mejora del 30% en la eficiencia energetica para 2040, segun lo establecido en la Ley de Politica Publica Energetica de Puerto Rico (Ley 17). Desde los huracanes Irma y Maria en septiembre de 2017, DOE y sus laboratorios nacionales han proporcionado a las partes interesadas del sistema energetico de Puerto Rico herramientas, adiestramiento y apoyo de modelaje para permitir la planificacion y el funcionamiento de la red electrica con mas resiliencia frente a nuevas interrupciones. El 2 de febrero de 2022, DOE, FEMA y seis laboratorios nacionales lanzaron el Estudio de Resiliencia de la Red Electrica de Puerto Rico y Transicion a la Energia 100% Renovable (PR100), de dos anos de duracion, para llevar a cabo un analisis exhaustivo de las vias impulsadas por las partes interesadas para el futuro energetico de Puerto Rico. El analisis energetico, solido y objetivo, comprende cinco actividades, con enfasis en la confiabilidad del sistema electrico, la resiliencia y la planificacion de la generacion. Esta presentacion se realizo en un seminario web publico el 21 de julio del 2022, proporcionando un resumen general del progreso en los primeros seis meses del Estudio, incluyendo la presentacion de cuatro escenarios iniciales definidos mediante un rol activo de las partes interesadas. This is the Spanish translation of NREL/PR-6A20-83431.

14 SOLAR ENERGY↗

Estudio de Resiliencia de la Red Electrica de Puerto Rico y Transicion a Energia 100% Renovable (PR100): Actualizacion de Progreso de Seis Meses [Slides]

Puerto Rico se ha comprometido a satisfacer sus necesidades de electricidad con un 100% de energia renovable para 2050, junto con el cumplimiento de objetivos intermedios del 40% para 2025, el 60% para 2040, la eliminacion gradual de la generacion a base de carbon para 2028, y una mejora del 30% en la eficiencia energetica para 2040, segun lo establecido en la Ley de Politica Publica Energetica de Puerto Rico (Ley 17). Desde los huracanes Irma y Maria en septiembre de 2017, DOE y sus laboratorios nacionales han proporcionado a las partes interesadas del sistema energetico de Puerto Rico herramientas, adiestramiento y apoyo de modelaje para permitir la planificacion y el funcionamiento de la red electrica con mas resiliencia frente a nuevas interrupciones. El 2 de febrero de 2022, DOE, FEMA y seis laboratorios nacionales lanzaron el Estudio de Resiliencia de la Red Electrica de Puerto Rico y Transicion a la Energia 100% Renovable (PR100), de dos anos de duracion, para llevar a cabo un analisis exhaustivo de las vias impulsadas por las partes interesadas para el futuro energetico de Puerto Rico. El analisis energetico, solido y objetivo, comprende cinco actividades, con enfasis en la confiabilidad del sistema electrico, la resiliencia y la planificacion de la generacion. Esta presentacion provee una actualizacion de progreso del trabajo de seis meses sobre el Estudio, incluyendo la presentacion de cuatro escenarios iniciales definidos mediante un rol activo de las partes interesadas. This is the Spanish translation of NREL/PR-6A20-83432.

14 SOLAR ENERGY↗

Plant Growth Study: Growth of Three Plant Species in 100-OL-1 Operable Unit Soils

Soil contamination from historical application of lead arsenate pesticides persists in the 100-OL-1 Operable Unit (OU) of the U.S. Department of Energy’s Hanford Site in Benton County, Washington. A remedial investigation used a portable X-ray fluorescence analyzer to estimate and map the concentrations of metals in surface soil in the 133 decision units comprising the OU. There is variability in lead and arsenic concentrations among the non-contiguous decision units, and an incomplete understanding of the ecological and human risks from soil contamination. While general screening criteria for lead are reported in literature, limited information is available on the impacts of heavy metals on site-specific plant and animal life. To address this information gap, a study on plant growth in Hanford soils was conducted using native bluegrass (Poa secunda), invasive cheatgrass (Bromus tectorum), and buttercrunch lettuce (Lactuca sativa). The latter is included because it is a common species used in plant growth studies. Soil samples were collected from a single general location within the 100-OL-1 OU, prepared, and categorized as having low, medium, or high concentrations of lead and arsenic, with the high concentration soil having concentrations of up to 3,400 and 790 mg/kg lead and arsenic, respectively. Additionally, a synthetic soil was prepared and used as a control, in accordance with standard plant growth protocols. Fifty-four seeds of each plant species were planted in each of the four soil types following the procedure outlined by the Washington State Department of Ecology. Germination rates and biomass measurements were recorded for 20 days. Both bluegrass and lettuce germination rates appeared to be reduced at the highest lead and arsenic concentrations (Pb: 3400 mg/kg, As: 790 mg/kg), while cheatgrass germination rates were unaffected. Total biomass for all species appeared to be related to the relative concentrations of lead and arsenic in the soil. Results of this growth study agree reasonably well with previous Hanford Site plant growth studies and provide additional data for assessing ecological risk at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

ReNew100: Reliable Power System Operation with 100% Renewable Generation

The ReNew100 project has developed and demonstrated an operator support system (OSS) to operate power systems with 100% renewable power generation from inverter-based resources (IBRs) like wind and solar that significantly reduces the risk of widespread power outages in a simulated operational environment at Technology Readiness Level (TRL) 6. The OSS achieves resilient operation for power systems under changing operation modes including varying combinations of conventional and renewable generation, including cases with 100% renewable generation from wind and solar IBRs. The OSS continuously monitors the N-1 security of the power system, which refers to the ability of the power systems to survive single outages of power system elements, like the loss of a generator or a power line, without causing widespread power outages beyond those expected and planned for. If the OSS identifies that the system is not N-1 secure, an automatic Controller Parameter Optimization (CoPO) developed within Renew100 is activated to optimize the N-1 security of the system by tuning controller parameters within different assets like batteries, wind, and solar plants. The core innovation of ReNew100 is the development of this CoPO as well as the demonstration of the OSS for a real-time simulation of the Hawai'i Island power system. Moreover, Renew100 has developed new model calibration techniques for dynamic power system models and demonstrated them for Hawai'i Island.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Determination of the spins and parities for the $0^+_4$ and $0^+_5$ states in $^{100}Zr$

Two 0 + states at 1294.5 and 1774.0 keV, together with three 2 + and one 4 + levels, were identified or unambiguously spin-parity assigned for the first time in 100 Zr utilizing γ-ray spectroscopy and γ-γ angular correlation techniques with the Gammasphere spectrometer, following the β - decay of neutron-rich, mass separated 100,100m Y isotopes. Comparisons with recent Monte Carlo Shell-Model (MCSM) calculations indicate that these two states are candidates for the bandhead of a sequence in a shape-coexisting spherical minimum predicted to be located around ≈1500 keV. According to the measured relative B(E2) relative transition probabilities, the 0+ 5 state exhibits decay properties which more closely align with those predicted for a spherical shape, while the $0^+_4$ level is suggested to be associated with a weakly-deformed shape similar to one related to the $0^+_2$ state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of the spins and parities for the $0$$^{+}_{4}$ and $0$$^{+}_{5}$ states in 100 Zr

Two 0 + states at 1294.5 and 1774.0 keV, together with three 2 + and one 4 + levels, were identified or unambiguously spin-parity assigned for the first time in 100 Zr utilizing γ-ray spectroscopy and γ-γ angular correlation techniques with the Gammasphere spectrometer, following the β¯ decay of neutron-rich, mass separated 100,100m Y isotopes. Comparisons with recent Monte Carlo Shell-Model (MCSM) calculations indicate that these two states are candidates for the bandhead of a sequence in a shape-coexisting spherical minimum predicted to be located around ≈1500 keV. According to the measured relative B(E2) relative transition probabilities, the $0$$^{+}_{5}$ state exhibits decay properties which more closely align with those predicted for a spherical shape, while the $0$$^{+}_{4}$ level is suggested to be associated with a weakly-deformed shape similar to one related to the $0$$^{+}_{2}$ state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Risk Analysis of a 100 MW Hydrogen Generation Facility near a Nuclear Power Plant

Nuclear power plants (NPPs) are considering flexible plant operations to take advantage of excess thermal and electrical energy. One option for NPPs is to pursue hydrogen production through high temperature electrolysis as an alternate revenue stream to remain economically viable. The intent of this study is to investigate the risk of a 100 MW hydrogen production facility in close proximity to an NPP. Previous analyses have evaluated preliminary designs of a hydrogen production facility in a conservative manner to determine if it is feasible to co-locate the facility within 1 km of an NPP. This analysis specifically evaluates the risk components of a 100 MW hydrogen production facility design, including the likelihood of a leak within the system and the associated consequence to critical NPP targets. This analysis shows that although the likelihood of a leak in an HTEF is not negligible, the consequence to critical NPP targets is not expected to lead to a failure given adequate distance from the plant.

08 HYDROGEN↗

A Review of Carbon-14 Removal by Ion Exchange Resins and Potential Remediation Application in the 100-K Area

During operations at the U.S. Department of Energy Hanford Site, releases of chemical and radioactive waste resulted in contamination of the soil and groundwater beneath portions of the site, including inadvertent releases of carbon-14 in the 100-K Area. Ongoing environmental cleanup efforts in the 100-K Area are focused on hexavalent chromium [Cr(VI)] and thus have not yet addressed the two carbon-14 groundwater plumes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

C-C Coupling Mechanism on Cu(100) A Molecular Dynamics Study at 298K

The electrochemical reduction of carbon dioxide (CO2) into valuable fuels such as C1 (syngas, methane) and C2 (ethylene, ethanol) products is a key strategy for achieving a carbon-neutral economy. Computational studies of C-C coupling, a critical step in CO2 reduction, are essential for designing more efficient catalysts. However, simulating these processes under realistic electrochemical conditions, including temperature and solvent effects, is computationally demanding. In this work, we develop a machine learning-based atomistic potential to study CO2 reduction on Cu(100) surfaces, accounting for temperature and explicit water solvent effects. We compute thermodynamic free energies of the possible C-C coupling pathways, CO*+CO*→OCCO*, CO*+CHO*→OCCHO*, CO*+COH*→OCCOH*, CHO*+COH*→OHCCOH*, COH*-COH*→HOCCOH*, and CHO*-CHO*→OHCCHO*. Our results quantify the thermodynamic tendencies of these reactions and reveal that, in addition to the well-established CO* + CO* → OCCO* pathway, CHO* is a critical intermediate in the formation of C2 products on Cu(100). Furthermore, we demonstrate that the machine learning approach offers a cost-efficient framework for studying CO2 reduction on diverse catalysts under realistic electrochemical conditions.

machine learning↗

Analysis of Crystalline Defects Caused by Growth on Partially Planarized Spalled (100) GaAs Substrates

We analyze the effect of growth on non-(100) surfaces resulting from incomplete planarization of spalled GaAs wafers on the defect structure of GaAs solar cell layers grown by hydride vapor phase epitaxy (HVPE). Controlled spalling of (100)-oriented GaAs has the potential to reduce substrate costs for III-V epitaxy; however, it creates regularly faceted surfaces that may complicate the growth of high-quality III-V optoelectronic devices. We leverage the anisotropic growth rate of HVPE to planarize these faceted GaAs substrates, reducing the surface roughness and degree of faceting. We observe degraded solar cell performance and material quality in sample areas where facets are not completely removed. We used dark lock-in thermography and photoluminescence to identify recombination in areas that were not fully planarized. We used cathodoluminescence to identify the presence of extended defects in these regions, which are correlated with bandgap fluctuations in the material. We hypothesize that these defects were created by strain from compositional fluctuations in ternary alloys grown on the faceted surfaces. This work elucidates the potential issues of solar cells grown on faceted surfaces and builds understanding toward realizing high performance III-V photovoltaics with the cost-reduction potential of controlled spalling.

14 SOLAR ENERGY↗

Assessment of dislocation reduction on 100 mm diameter bulk GaN grown by the NEAT method

X-ray topography measurements on a 100 mm diameter GaN boule grown by the Near Equilibrium AmmonoThermal method revealed an improvement in dislocation density from >1 × 10 6 cm -2 to between 2 × 10 5 and 5 × 10 5 cm -2, an improvement greater than two to five times from seed to growth. This data builds on previous X-ray diffraction and defect selective etching to quantify the reduction in defect density that is closely associated with increasing growth thickness. This result indicates that there is a pathway to further dislocation reduction by increasing growth thickness for GaN crystals including those of 100 mm or larger diameter. Further reduction of the dislocation density of large-area substrates will lead to GaN power devices with reduced leakage current under reverse bias and better device performance.

36 MATERIALS SCIENCE↗

The 100 pc White Dwarf Sample in the SDSS Footprint

In this work, we present follow-up spectroscopy of 711 white dwarfs within 100 pc, and we present a detailed model atmosphere analysis of the 100 pc white dwarf sample in the Sloan Digital Sky Survey footprint. Our spectroscopic follow-up is complete for 83% of the white dwarfs hotter than 6000 K, where the atmospheric composition can be constrained reliably. We identify 1508 DA white dwarfs with pure hydrogen atmospheres. The DA mass distribution has an extremely narrow peak at 0.59 M ⊙ and reveals a shoulder from relatively massive white dwarfs with M = 0.7–0.9 M ⊙. Comparing this distribution with binary population synthesis models, we find that the contribution from single stars that form through mergers cannot explain the overabundance of massive white dwarfs. In addition, the mass distribution of cool DAs shows a near absence of M > 1 M ⊙ white dwarfs. The pile-up of 0.7–0.9 M ⊙ and the disappearance of M > 1 M ⊙ white dwarfs is consistent with the effects of core crystallization. Even though the evolutionary models predict the location of the pile-up correctly, the delay from the latent heat of crystallization by itself is insufficient to create a significant pile-up, and additional cooling delays from related effects like phase separation are necessary. We also discuss the population of infrared-faint (ultracool) white dwarfs and demonstrate for the first time the existence of a well-defined sequence in color and magnitude. Curiously, this sequence is connected to a region in the color–magnitude diagrams where the number of white dwarfs with a helium-dominated atmosphere is low. This suggests that the infrared-faint white dwarfs likely have mixed H/He atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗