Search NASASearch

SEARCH · Search NASA

Results for “24/7”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

317 records · Page 9

Advanced Non-Intrusive Instrumentation for Propulsion Engines

Changes in engine technology such as higher temperatures, higher tip speeds, new metal/composite/ceramic materials together with radical changes in design philosophy will require amongst other prerequisites the ability to measure and to monitor key internal gas and structural characteristics. The symposium papers presented non-intrusive measurement and analysis technologies in the following categories: Laser Point Measurements (11); Absorption and Infrared Techniques (4); Paints - Surface Sensors (6); Laser Induced Fluorescence (6); Mechanical (7); Films (5); Laser Planar Measurement (9); and a Keynote Address.

Propulsion

Four Years of Type Ia Supernovae Observed by TESS: Early-time Light-curve Shapes and Constraints on Companion Interaction Models

Abstract We present 307 type Ia supernova (SN) light curves from the first 4 yr of the Transiting Exoplanet Survey Satellite mission. We use this sample to characterize the shapes of the early-time light curves, measure the rise times from first light to peak, and search for companion star interactions. Using simulations, we show that light curves must have noise <10% of the peak flux to avoid biases in the early-time light-curve shape, restricting our quantitative analysis to 74 light curves. We find that the mean power-law index t β 1 of the early-time light curves isβ 1 = 1.93 ± 0.57, and the mean rise time to peak is 15.7 ± 3.5 days. The underlying population distribution forβ 1 may instead consist of a Gaussian component with mean 2.29, width 0.34, and a long tail extending to values less than 1.0. We find that the data can rarely distinguish between models with and without companion interaction models. Nevertheless, we find three high-quality light curves that tentatively prefer the addition of a companion interaction model, but the statistical evidence for the companion interactions is not robust. We also find two SNe that disfavor the addition of a companion interaction model to a curved power-law model. Taking the 74 SNe together, we calculate 3σupper limits on the presence of companion signatures to control for orientation effects that can hide companions in individual light curves. Our results rule out common progenitor systems with companions having Roche lobe radii >31R ⊙ (separations >5.7 × 10 12 cm, 99.9% confidence level) and disfavor companions having Roche lobe radii >10R ⊙ (separations >1.9 × 10 12 cm, 95% confidence level). Lastly, we discuss the implications of our results for the intrinsic fraction of single degenerate progenitor systems.

Astronomy & Astrophysics

RMCProfile7 : reverse Monte Carlo for multiphase systems

This work introduces a completely rewritten version of the programRMCProfile(version 7), big-box, reverse Monte Carlo modelling software for analysis of total scattering data. The major new feature ofRMCProfile7is the ability to refine multiple phases simultaneously, which is relevant for many current research areas such as energy materials, catalysis and engineering. Other new features include improved support for molecular potentials and rigid-body refinements, as well as multiple different data sets. An empirical resolution correction and calculation of the pair distribution function as a back-Fourier transform are now also available.RMCProfile7is freely available for download at https://rmcprofile.ornl.gov/.

Chemistry

Reduced-order CFD modeling of cryogenic hydrogen isotope extrusion for pellet fueling

This study presents a reduced-order model (ROM) for computational fluid dynamics (CFD) simulations of cryogenic hydrogen isotope extrusions, focusing on protium (H₂) and deuterium (D₂) piston extruders. Using a 2D axisymmetric ROM in ANSYS-Polyflow, significant computational savings were achieved (runtime reduced from 9∼24 h to 3∼5 min), with extrusion force discrepancies between the 2D ROM and 3D models being on the order of 1%. Parametric studies identified optimal cutoff shear rates in the viscosity model (0.01/s for H₂ and 0.001/s for D₂), providing recommendations for future simulations. Finally, a comprehensive comparison of ROM results with experimental data was performed across varying geometries, cryogenic materials, temperatures, extrusion lengths, and piston velocities. Predictions at low extrusion temperatures met the objective of providing quick and efficient solutions with an acceptable extrusion force error of approximately 10% or less, validating the effectiveness of the 2D ROM approach. However, at high temperatures closer to the triple point, extrusion force error grows, which necessitates developing an improved model that accounts for temperature effects, e.g. melting. Nevertheless, the findings still represent a significant improvement in efficiency of CFD modeling of cryogenic hydrogenic extrusion. The ROM framework can also be extended to tritium (T2) and screw extruders, which will ultimately provide a fast and effective tool for optimizing pellet injector design for ITER and future reactor systems.

Fan, Joy [ORNL] (ORCID:0000000229751735)

Plasma phosphorylated tau217 strongly associates with memory deficits in the Alzheimer’s disease spectrum

Abstract Plasma phosphorylated tau (p-tau) biomarkers open unprecedented opportunities for identifying carriers of Alzheimer’s disease pathophysiology in early disease stages using minimally invasive techniques. Plasma p-tau biomarkers are believed to reflect tau phosphorylation and secretion. However, it remains unclear to what extent the magnitude of plasma p-tau abnormalities reflects neuronal network disturbance in the form of cognitive impairment. To address this question, we included 103 cognitively unimpaired elderly and 40 cognitively impaired, amyloid-β-positive individuals from the TRIAD cohort, in addition to 336 cognitively unimpaired and 216 cognitively impaired, amyloid-β-positive older adults from the BioFINDER-2 cohort. Participants had tau PET scans, amyloid PET scans or amyloid CSF, p-tau217, p-tau181 and p-tau231 blood measures, structural T1-MRI and cognitive assessments. In this cross-sectional study, we used regression models and correlation analyses to assess the relationship between plasma biomarkers and cognitive scores. Furthermore, we applied receiver operating characteristic curves to assess cognitive impairment across plasma biomarkers. Finally, we categorized participants into amyloid (A), p-tau (T1) and tau PET (T2) positive (+) or negative (−) profiles and ran non-parametric comparisons to assess differences across cognitive domains. We found that plasma p-tau217 was more associated with cognitive performance than p-tau181 and p-tau231 and that this relationship was particularly strong for memory scores (TRIAD: βp-tau217 = −0.53, βp-tau181 = −0.35 and βp-tau231 = −0.24; BioFINDER-2: βp-tau217 = −0.52, βp-tau181 = −0.24 and βp-tau231 = −0.29). Associations in amyloid-β-positive participants resembled these results, but other cognitive scores also showed strong associations in cognitively impaired individuals. Moreover, plasma p-tau217 outperformed plasma p-tau181 and plasma p-tau231 in identifying memory impairment (area under the curve values for TRIAD: p-tau217 = 0.86, p-tau181 = 0.77 and p-tau231 = 0.75; and for BioFINDER-2: p-tau217 = 0.86, p-tau181 = 0.76 and p-tau231 = 0.81) and in identifying executive function impairment only in the BioFINDER-2 cohort (p-tau217 = 0.82, p-tau181 = 0.76 and p-tau231 = 0.76). Lastly, we showed that subtle memory deficits were present in A+T1+T2− participants for plasma p-tau217 (P = 0.007) and plasma p-tau181 (P = 0.01) in the TRIAD cohort and for all biomarkers across cognitive domains in A+T1+T2− and A+T1+T2− individuals (P < 0.001 in all) in the BioFINDER-2 cohort. The A+T1+T2− individuals showed cognitive deficits in both cohorts (P < 0.001 in all). Together, our results suggest that plasma p-tau217 stands out as a biomarker capable of identifying memory deficits attributable to Alzheimer’s disease and that memory impairment certainly occurs in amyloid-β- and plasma p-tau-positive individuals who have no significant amounts of tau in the neocortex.

Neurosciences & Neurology

Copacabana: a probabilistic membership assignment method for galaxy clusters

Cosmological analyses using galaxy clusters in optical/near-infrared photometric surveys require robust characterization of their galaxy content. Precisely determining which galaxies belong to a cluster is crucial. In this paper, we present the COlor Probabilistic Assignment of Clusters And BAyesiaN Analysis (Copacabana) algorithm. Copacabana computes membership probabilities for all galaxies within an aperture centred on the cluster using photometric redshifts, colours, and projected radial probability density functions. We use simulations to validate Copacabana and we show that it achieves up to 89 per cent membership accuracy with a mild dependence on photometric redshift uncertainties and choice of aperture size. We find that the precision of the photometric redshifts has the largest impact on the determination of the membership probabilities followed by the choice of the cluster aperture size. We also quantify how much these uncertainties in the membership probabilities affect the stellar mass–cluster mass scaling relation, a relation that directly impacts cosmology. Using the sum of the stellar masses weighted by membership probabilities (⁠μ * ⁠) as the observable, we find that Copacabana can reach an accuracy of 0.06 dex in the measurement of the scaling relation at low redshift for a Legacy Survey of Space and Time type survey. These results indicate the potential of Copacabana and μ * to be used in cosmological analyses of optically selected clusters in the future.

79 ASTRONOMY AND ASTROPHYSICS

Multitarget Rydberg gates via spatial blockade engineering

Multi-target gates offer the potential to reduce gate depth in syndrome extraction for quantum error correction. Although neutral-atom quantum computers have demonstrated native multi-qubit gates, existing approaches that avoid additional control or multiple atomic species have been limited to single-target gates. We propose single-control-multi-target CZ^n gates on a single-species neutral-atom platform that require no extra control and have gate durations comparable to standard CZ gates. Our approach leverages tailored interatomic distances to create an asymmetric blockade between the control and target atoms. Using a GPU-accelerated pulse synthesis protocol, we design smooth control pulses for CZZ and CZZZ gates, achieving fidelities of up to 99.55% and $99.24\%$, respectively, even in the presence of simulated atom placement errors and Rydberg-state decay. Our approach is most effective for N=2 (CZZ) and N=3 targets (CZZZ); for larger N, increasing spatial crowding of the targets introduces significant challenges for maintaining the required blockade asymmetry. This work presents a practical path to implementing low-overhead multi-target gates in single-species neutral-atom systems, significantly reducing the resource overhead for syndrome extraction. To motivate the impact of these gates, we apply a greedy scheduling algorithm and we demonstrate that our proposed gates can reduce the number of atom reconfiguration costs by up to 50% for color code syndrome extraction of code distances greater than 5.

Stein, Samuel A.

Hybrid Thermally Efficient Core (HyTEC) Phase 1 3-Stage Compressor Rig Final Report - Unlimited Rights

The HyTEC Phase 1 3-Stage Compressor Rig project was conducted to mature and validate front-stage aerodynamic technologies in support of HyTEC Phase 2 and GEA’s Compact Core compressor. Building on the prior ERA Phase 2 Baseline Rig, GEA and NASA collaborated on the design and testing of the HyTEC rig, incorporating advanced technologies such as increased radius ratio, higher aerodynamic loading, and advanced casing treatment. The HyTEC test campaign leveraged similar design and instrumentation philosophy, test execution approach, and the same facility (NASA W-7) to enable clear comparison with the legacy ERA rig results. The HyTEC rig was designed to deliver benefits in efficiency, tip loading, operability, and aeromechanics, with success measured against defined TPMs that were anchored to the ERA baseline rig data.

Axial Compressors

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Modeling Flow in a Microreactor Core: From High-Fidelity CFD to Subchannel Analysis

The accurate prediction of pressure drop in tightly packed, low–Reynolds number (Re) bare rod bundles is essential for the thermal-hydraulic design of the Microreactor Applications Research Validation and EvaLuation (MARVEL) reactor and other microreactor concepts. However, existing friction factor correlations, particularly the upgraded Cheng-Todreas (UCTD) correlation, have limited validation for the small pitch-to-diameter ratios (P/Ds) and transitional flow conditions characteristic of these systems. In this work, we perform high-fidelity large-eddy simulations (LESs) of both an infinite bare rod bundle and a finite bare 37-pin scalloped rod bundle across the range 1000≤ 𝑅𝑒 ≤5500. The simulations reveal strong gap vortex–driven transitional behavior and indicate that the UCTD may underpredict the friction factor by up to 28% at 𝑃/𝐷 = 1.05. Using the LES-calculated pressure drops, we formulate a new friction factor correlation that follows the Cheng-Todreas functional form but is calibrated for low-Re and tightly packed geometries representative of a MARVEL-like reactor. The correlation is implemented in the MOOSE (Multiphysics Object-Oriented Simulation Environment) subchannel module and compared against both the LES and UCTD predictions. Across all subchannel types, the proposed model reduces the streamwise velocity differences from as high as 44% (UCTD) to below 9%, and decreases the pressure gradient differences from 13% to 25% (UCTD) to 0.7% to 7% relative to the LES results. These results suggest that the new correlation has the potential to improve the pressure drop and flow field predictions for such geometries, highlighting the importance of high-fidelity simulations in supporting microreactor thermal-hydraulic model development and motivating future pressure drop experiments for compact rod bundles to further validate these findings.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN

Summary of Research Report

Ten papers, published in various publications, on buckling, and the effects of imperfections on various structures are presented. These papers are: (1) Buckling mode localization in elastic plates due to misplacement in the stiffner location; (2) On vibrational imperfection sensitivity on Augusti's model structure in the vicinity of a non-linear static state; (3) Imperfection sensitivity due to elastic moduli in the Roorda Koiter frame; (4) Buckling mode localization in a multi-span periodic structure with a disorder in a single span; (5) Prediction of natural frequency and buckling load variability due to uncertainty in material properties by convex modeling; (6) Derivation of multi-dimensional ellipsoidal convex model for experimental data; (7) Passive control of buckling deformation via Anderson localization phenomenon; (8)Effect of the thickness and initial im perfection on buckling on composite cylindrical shells: asymptotic analysis and numerical results by BOSOR4 and PANDA2; (9) Worst case estimation of homology design by convex analysis; (10) Buckling of structures with uncertain imperfections - Personal perspective.

Isaac Elishakoff

Direct Observation of Elusive (DTBM‐SEGPHOS)CuH Monomer Enables Mechanistic Insights Into Hydrocupration, Aggregation, and Dynamics of Alkene Functionalization Catalysis

The bulky diphosphine DTBM-SEGPHOS is widely employed in CuH-catalyzed transformations as it provides remarkably active catalyst systems. The transient (DTBM-SEGPHOS)CuH monomer (LCuH) is the often-invoked active species. However, its instability has prevented spectroscopic characterization and mechanistic elucidation, hindering mechanistic understanding. We report low-temperature NMR spectroscopic characterization of LCuH, enabling quantitative kinetic analysis of the stoichiometric hydrocupration and catalytic hydroboration of cyclopentene, as well as the structural identification of two CuH clusters. LCuH inserts cyclopentene at −43°C, reaffirming its high reactivity toward olefins. LCuH deactivates to form L 2 Cu 3 H 3 and L 2 Cu 4 H 4 clusters, in which LCuH dimerization initiates aggregation. Kinetic analysis of reactions of unactivated alkenes indicates that competing on-cycle alkene hydrocupration and LCuH dimerization impact performance, as catalyst deactivation and turnover occur on comparable timescales. Structure–activity analysis using atomistic simulations shows that the steric profile of DTBM-SEGPHOS increases the CuH dimerization barrier by ∼7.7 kcal mol−1 compared to that of SEGPHOS, rationalizing the unique ability of DTBM-SEGPHOS to stabilize a reactive monomer for hydrocupration of broader alkene substrates. These findings illustrate the fundamental design principle that steric control of aggregation governs CuH catalyst performance, explaining both the exceptional activity of (DTBM-SEGPHOS)CuH and the limitations imposed by competing deactivation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Methane at Elevated Temperature

This paper examines the effect of varying the liquid temperature and pressure on the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid methane using gaseous helium across a wide range of elevated pressures and temperatures. Testing of a 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenic Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 105 to 160K and 0.0965 – 1.78 MPa. Bubble point is shown to be a strong function of the liquid temperature and a weak function of the amount of subcooling at the LAD screen. The model predicts well for saturated liquid but under predicts the subcooled data.

Reaction Control System

Weak localization and universal conductance fluctuations in large-area twisted bilayer graphene

We study diffusive magnetotransport in highly 𝑝-doped large-area twisted bilayer graphene in 1∘, 7∘, 9∘, and 20∘ samples. All samples exhibit weak localization, from which we extract the phase coherence length and intervalley scattering lengths, and from that determine that dephasing is caused by electron-electron scattering and intervalley scattering is caused by point defects. We observe signatures of universal conductance fluctuations in the 9∘ sample, which has high mobility and is near the van Hove singularity. Further improvements in sample quality and applications to large-area moiré materials will open new avenues to observe quantum interference effects.

Talkington, Spenser [University of Pennsylvania]

Healable Coatings as a Mechanism to Repair Leading Edge Erosion in Wind Energy

Wind turbine blades are highly engineered structures designed to face temperature extremes and high winds. However, erosion of the blade's leading edge and subsequent repair remains a significant and costly challenge for the wind energy industry. Repair of these leading edges can lead to large amounts of downtime for the turbine and significant operational inefficiencies. In this work, the strength of adhesion and healing ability of a commercially available vitrimer (Mallinda's VITRIMAX) was compared to that of a thermoplastic resin, which has previously been demonstrated in wind energy applications (Arkema's Elium) to evaluate their efficacy as surface coatings for wind turbine blades, particularly their leading edges. Vitrimers are a class of inherently reprocessable thermosets, and it was theorized that vitrimer-based leading edge coatings could enable more robust and efficient wind turbine blades with decreased operational downtime and safer maintenance practices. It was found that the VITRIMAX adhered better to the wind blades' surfaces than both the manufacturer's paint and Elium, with increases in pull-off strength of adhesion ranging from 24% to 83% above that of the original paint. Furthermore, the VITRIMAX adhered strongly to the underlying composite of each blade with strength of adhesion values increasing in ranges from 42% to 97% above that of the original paint. Finally, the vitrimer coating showed an 88% decrease in surface roughness compared to end-of-life blade materials, and initial healing demonstrations in which coatings were manually scratched and subsequently healed exhibited an ~84.5% decrease in scratch depths.

Hubbard, Amber [ORNL]

Enhanced Optical Contrast and Switching in Near‐Infrared Electrochromic Devices by Optimizing Conjugated Polymer Oligo(Ethylene Glycol) Sidechain Content and Gel Electrolyte Composition

Abstract A detailed investigation addressing the effects of functionalizing conjugated polymers with oligo(ethylene glycol) (EG n ) sidechains on the performance and polymer‐electrolyte compatibility of electrochromic devices (ECDs) is reported. The electrochemistry for a series of donor‐acceptor copolymers having near‐infrared (NIR)‐optical absorption, where the donor fragment is 3,4‐ethylenedioxythiophene (EDOT) or an EG n functionalized bithiophene (g2T) and the acceptor fragment is diketopyrrolopyrrole (DPP) functionalized with branched alkyl or EG n sidechains, is extensively probed. ECDs are next fabricated and it is found that EG n sidechain incorporation must be finely balanced to promote polymer‐electrolyte compatibility and provide efficient ion exchange. Proper electrolyte‐cation pairing and polymer structural tuning affords a 2x increase in optical contrast (from 12% to 24%) and >60x reduction in switching time (from 20 to 0.3 s). Atomic force microscopy (AFM)/grazing incidence wide‐angle X‐ray scattering (GIWAXS) characterization of the polymer film morphology/microstructure reveals that an over‐abundance of EG n sidechains generates large polymer crystallites, which can suppress ion exchange. Lastly, time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) indicates sidechain/electrolyte identity does not influence the electrolyte penetration depth into the films, and EG n sidechain inclusion increases electrolyte cation uptake. The material structural design insight and guidelines regarding the polymer‐electrolyte ion insertion/expulsion dynamics reported here should be of significant utility for developing next‐generation mixed ionic‐electronic conducting materials.

Chemistry

Simulation to a Newborn Supernova Remnant from a Low-mass Iron Core Star

Supernova remnant observations show a high degree of asymmetry, mixing, and inhomogeneity. These asymmetries are seeded during the early seconds of the explosion and are further enhanced and modified as the shock and ejecta move through the stellar progenitor and into the circumstellar medium. We present simulations of a 9.6 M⊙ zero-metallicity progenitor initialized after shock revival and evolved for several years when the ejecta is in the circumstellar medium. A suite of 1D and 2D simulations examines the effects of neutron-star wind and radioactive decay heating. In 1D, decay heating forms a low-density bubble that suppresses the reverse shock. While in 2D, the heating is localized to metal-rich pockets, inflating them and compressing the surrounding material into dense shells. In 3D, the neutron-star wind and decay heating modify the plume morphology, producing more large-scale structures. The extended plume morphology leads to an asymmetrical shock breakout. After breakout, the leading plumes cannot keep up with the shock front, resulting in deceleration and fragmentation by the reverse shock while retaining the large-scale asymmetry. The projected ejecta morphology and velocities are strongly viewing angle dependent. The relatively uniform metal-rich distribution does not resemble the strongly inhomogeneous ejecta structure of Cas A. The 160-isotope decay network shows that 24.4% of the radioactive heating comes from decay chains other than the canonical 56Ni chain. The low explosion energy, low 56Ni yield, and Ni/Fe ratio greater than unity suggest an observational signature similar to an electron capture supernova.

Neopane, Sudarshan [University of Tennessee (UT)]

Copper-Wire-Card Detectors

Card Design - Each copper-wire-card detector consisted of a winding of fine wire mounted to a 1.45- by 7 .00-inch rectangular card. Two wire sizes were used - 2-mil and 3-mil (fourteen 2-mil cards and thirty-two 3-mil cards). The total exposed effective area was about 1.2 square feet (0.11 square meters). A sketch of a detector is shown in figure X-1. These detectors are similar to the detectors flown on previous satellites. Quadrant Design - The 36 cards are arranged in four groups of 12 cards each with four pairs of 3-mil cards in parallel and four single 2-mil cards in parallel. Each group is mounted on a fiber-glass support that can readily be removed from the payload for repairs or replacements with appropriate spares. Individual cards can be replaced readily if necessary. The assembly of the quadrants is shown in figure II-2. Temperature-Balance Experiment - The grids for the temperature-balance experiment were wound with insulated wire. The thermal balance of such a winding has been examined under conditions approximating flight environment. One card of 3-mil wire with a thermistor attached was enclosed in a bell jar and exposed to the sun after evacuation. External radiation was reduced by shading the bell jar except for a window which allowed the sun's rays to strike the winding. The temperature of the thermistor was recorded at intervals. Figure X-2 shows that the temperature does not rise beyond 65° C in 20 minutes of continuous exposure to the sun. Complementary tests made by Dr. Roger E. Gaumer of Lockheed Aircraft Corp. give a ratio of absorptivity to emissivity of 1 for this type of enamel insulated wire. Compensation for Resistance Changes - Temperatures at the wire-card surfaces were expected to extend from -10° C to a maximum of 60° C. Since copper has a thermal coefficient of resistance of 0.33 percent per °C, the resistance of the wire would change 22 percent and a compensator had to be provided. A 100-ohm thermistor with a negative coefficient of -3-9 percent per °C was selected, wired in parallel with a 300-ohm fixed resistor and installed in series with each 2-mil card and with each pair of 3-mil cards. The effective resistance of 2-mil and 3-mil compensated cards is shown in figure X-3 for various temperatures and compared with the resistance of uncompensated copper. The increase in resistance from 20° C to 60° C is 12 ohms or 2.7 percent. Below 20° C the effective resistance also increases and the curve is similar to that obtained for high temperatures.

Detector