Search NASA⌕ Search

SEARCH · Search NASA

Results for “2D SCANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Actively triggered 4d cone-beam CT acquisition

Purpose: 4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this “after-the-fact” binning approach, however, projections are unevenly distributed over respiratory phases resulting in inefficient utilization of imaging dose. To avoid excess dose in certain respiratory phases, and poor image quality due to a lack of projections in others, the authors have developed a novel 4d CBCT acquisition framework which actively triggers 2d projections based on the forward-predicted position of the tumor.Methods: The forward-prediction of the tumor position was independently established using either (i) an electromagnetic (EM) tracking system based on implanted EM-transponders which act as a surrogate for the tumor position, or (ii) an external motion sensor measuring the chest-wall displacement and correlating this external motion to the phase-shifted diaphragm motion derived from the acquired images. In order to avoid EM-induced artifacts in the imaging detector, the authors devised a simple but effective “Faraday” shielding cage. The authors demonstrated the feasibility of their acquisition strategy by scanning an anthropomorphic lung phantom moving on 1d or 2d sinusoidal trajectories.Results: With both tumor position devices, the authors were able to acquire 4d CBCTs free of motion blurring. For scans based on the EM tracking system, reconstruction artifacts stemming from the presence of the EM-array and the EM-transponders were greatly reduced using newly developed correction algorithms. By tuning the imaging frequency independently for each respiratory phase prior to acquisition, it was possible to harmonize the number of projections over respiratory phases. Depending on the breathing period (3.5 or 5 s) and the gantry rotation time (4 or 5 min), between ∼90 and 145 projections were acquired per respiratory phase resulting in a dose of ∼1.7–2.6 mGy per respiratory phase. Further dose savings and decreases in the scanning time are possible by acquiring only a subset of all respiratory phases, for example, peak-exhale and peak-inhale only scans.Conclusions: This study is the first experimental demonstration of a new 4d CBCT acquisition paradigm in which imaging dose is efficiently utilized by actively triggering only those projections that are desired for the reconstruction process.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ultrafast two-photon fluorescence imaging of cerebral blood circulation in the mouse brain in vivo

Characterizing blood flow dynamics in vivo is critical to understanding the function of the vascular network under physiological and pathological conditions. Existing methods for hemodynamic imaging have insufficient spatial and temporal resolution to monitor blood flow at the cellular level in large blood vessels. By using an ultrafast line-scanning module based on free-space angular chirped enhanced delay, we achieved two-photon fluorescence imaging of cortical blood flow at 1,000 two-dimensional (2D) frames and 1,000,000 one-dimensional line scans per second in the awake mouse. This orders-of-magnitude increase in temporal resolution allowed us to measure cerebral blood flow at up to 49 mm/s and observe pulsatile blood flow at harmonics of heart rate. Directly visualizing red blood cell (RBC) flow through vessels down to >800 µm in depth, we characterized cortical layer–dependent flow velocity distributions of capillaries, obtained radial velocity profiles and kilohertz 2D velocity mapping of multifile blood flow, and performed RBC flux measurements from penetrating blood vessels.

59 BASIC BIOLOGICAL SCIENCES↗

Interpretable and Efficient Interferometric Contrast in Scanning Transmission Electron Microscopy with a Diffraction-Grating Beam Splitter

Efficient imaging of biomolecules, 2D materials and electromagnetic fields depends on retrieval of the phase of transmitted electrons. We demonstrate a method to measure phase in a scanning transmission electron microscope using a nanofabricated diffraction grating to produce multiple probe beams. The measured phase is more interpretable than phase-contrast scanning transmission electron microscopy techniques without an off-axis reference wave, and the resolution could surpass that of off-axis electron holography. Here, we apply the technique to image nanoparticles, carbon sub- strates and electric fields. The contrast observed in experiments agrees well with contrast predicted in simulations.

36 MATERIALS SCIENCE↗

3D Observation of GEMS by Electron Tomography

Amorphous silicates in chondritic porous interplanetary dust particles (CP-IDPs) coming from comets are dominated by glass with embedded metal and sulfides (GEMS). GEMS grains are submicron-sized rounded objects (typically 100-500) nm in diameter) with anaometer-sized (10-50 nm) Fe-Ni metal and sulfide grains embedded in an amorphous silicate matrix. Several formation processes for GEMS grains have been proposed so far, but these models are still being debated [2-5]. Bradley et al. proposed that GEMS grains are interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk and that they are amorphiation products of crystalline silicates in the interstellar medium by sputter-deposition of cosmic ray irradiation, similar to space weathering [2,4]. This consideration is based on the observation of nano-sized crystals (approximately 10 nm) called relict grains in GEMS grains and their shapes are pseudomorphs to the host GEMS grains. On the other hand, Keller and Messenger proposed that most GEMS formed in the protoplanetary disk as condensates from high temperature gas [3,5]. This model is based on the fact that most GEMS grains have solar isotopic compositions and have extremely heterogeneous and non-solar elemental compositions. Keller and Messenger (2011) also reported that amorphous silicates in GEMS grains are surrounded by sulfide grains, which formed as sulfidization of metallic iron grains located on the GEMS surface. The previous studies were performed with 2D observation by using transmission electron microscopy (TEM) or scanning TEM (STEM). In order to understand the structure of GEMS grains described above more clearly, we observed 3D structure of GEMS grains by electron tomography using a TEM/STEM (JEM-2100F, JEOL) at Kyoto University. Electron tomography gives not only 3D structures but also gives higher spatial resolution (approximately a few nm) than that in conventional 2D image, which is restricted by sample thickness ) approx. or greater than 50 nm). Three cluster IDPs (L2036AA5 cluster4, L2009L8 cluster 13 and W726A2) were used for the observations. ID W726A2 was collected without silicon oil, which is ordinary used to collect IDPs, so this sample has no possibility of contaminations caused by silicon oil or solvent to rinse it [6]. The samples were embedded in epoxy risin and sliced into ultrathin sections (50-300 nm) using an ultramicotome. The sections were observed by BF-TEM and HAADF-STEM (high angle annular dark field-scanning TEM) modes. Images were obtained by rotating the sample tilt angle over a range of +/- 65 deg in 1 deg steps. The obtained images were reconstructed to slice images. Mineral phases in the slice images were estimated by comparing with a 2D elemental map obtained by an EDS (energy dispersive X-ray spectroscopy) system equipped in the TEM/STEM. Careful examination of the slice images confirmed that iron grains are embedded in the amorphous silicate matrix of the GEMS grains, but sulfide grains were mainly present on the surface of the amorphous silicate. These results are consistent with the model that GEMS grains formed as condensates [3,5], although more data are needed to conclude the origin of GEMS grains. The present study is the first successful example adapting the electron tomography to the IDPs. This type of analysis will be important for planetary material sciences in the future.

Matsuno, Junya↗

Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts

Industrial X-ray computed tomography (XCT) enables non-destructive inspection of additively manufactured (AM) parts, but high-resolution scanning requires long acquisition times and significant computational resources, limiting throughput in production environments. Super-resolution techniques can recover high-resolution information from low-resolution scans, but existing methods face a trade-off between 2D approaches that ignore inter-slice information and 3D methods that are computationally prohibitive for practical deployment. To address this trade-off, we propose a 2.5D deep learning-based super-resolution approach that uses seven neighbouring low-resolution slices to super-resolve the centre slice. This work evaluates the method on real XCT scans of steel AM parts, comparing reconstruction quality and flaw detection performance of 2D, 2.5D, and 3D ESRGAN-based super-resolution methods. Results demonstrate that 2.5D super-resolution significantly improves detection of small, process-induced flaws (e.g. porosity) compared to 2D methods, while avoiding the prohibitive computational burden of full 3D approaches. These findings provide initial evidence of 2.5D super-resolution as a practical, deployable solution for improving flaw detection in high-throughput industrial XCT inspection.

X-ray CT↗

An integrated two-dimensional modeling method for predicting ductility of thin-walled die cast magnesium

In this paper, a two-dimensional (2D) microstructure-based modeling method is developed in order to predict the ductility of a thin-walled high pressure die cast magnesium (Mg) by considering the three-dimensional (3D) thru-thickness pore distributions. For this purpose, a series of 3D synthetic microstructure-based finite element models and the corresponding 2D models are first generated with various pore volume fractions, pore size distributions and pore shapes. The input material properties for the 2D models are determined based on the 3D cubic model with a spherical pore and the generalized Neuber’s rule. Based on the resulting ductility of the 3D and 2D models, a 3D/2D ductility correlation curve is developed as a function of the characteristics/shape of the input fracture strain curve used in the 3D model. The validity of the ductility correlation curve is examined with casting samples with actual microstructures. Here, the results show that the suggested 2D modeling methodology can be used together with the ductility correlation curve in predicting the ductility of thin-walled Mg castings.

36 MATERIALS SCIENCE↗

Resistivity of Surface Steps in Bulk-Insulating Topological Insulators

Electron transport in topological insulators usually involves both topologically protected surface states and trivial electronic states in the bulk material. The surface transport is particularly interesting; however, it is also susceptible to atomic defects on the surfaces, such as vacancies, impurities, and step edges. Experimental determination of scattering effects of these surface defects requires both nanoscale spatial resolution and the ability to decipher surface transport from bulk transport. Here we directly measure the resistivity of individual surface steps in the surface dominating transport process of topological insulator Bi 2 Te 2 Se. A variable probe-spacing transport spectroscopy with a multiprobe scanning tunneling microscope is used to differentiate the surface conductance from bulk conductance, allowing the identification of a surface dominant transport regime. The technique also reveals a deviation from ideal 2D transport at atomic steps. Then, a multi-probe scanning tunneling potentiometry is employed to visualize the electrochemical potentials across individual step edges. A quantitative analysis of the potential distributions enables us to acquire a resistivity of 0.530 mΩ · cm for the one quintuple-layer atomic step. The result indicates that atomic defects, despite preserving the time-reversal symmetry, can still significantly affect the transport in topological insulators.

36 MATERIALS SCIENCE↗

Parameter-free treatment of a layered correlated van der Waals magnet: CrPS 4

The electronic and magnetic structure of CrPS 4 , a two-dimensional (2D) magnetic semiconductor is examined by employing the SCAN meta-GGA density functional. We find the resulting magnetic moment and band gap are in excellent agreement with experiment. From the bulk magnetic configurations, we confirm the experimentally observed A-type antiferromagnetic (A-AFM) ordered ground state with a magnetic moment of 2.78 µ B per chromium atom and band gap of 1.34 eV. To gain insight into the evolution of the ground state with layers, the total energy of each magnetic configuration is calculated for a variety of thicknesses. Monolayer CrPS 4 is predicted to be a ferromagnetic insulator with a band gap of 1.37 eV, and A-AFM for bilayer and trilayer, with band gaps of 1.35 and 1.30 eV, respectively. The electronic structure is reported for the single-, two-, and three-layer and bulk CrPS 4 . Finally, we explore the optical properties of the 2D structure and report the dielectric tensor components and Kerr parameters for the monolayer.

2-dimensional systems↗

Quantitative wood–adhesive penetration with X-ray computed tomography

Micro X-ray computed tomography (XCT) was used to analyze the 3D adhesive penetration behavior of different wood–adhesive bondlines. Three adhesives, a phenol formaldehyde (PF), a polymeric diphenylmethane diisocyanate (pMDI), and a hybrid polyvinyl acetate (PVA), all tagged with iodine for enhanced X-ray attenuation, were used to prepare single-bondline laminates in two softwoods, Douglas-fir and loblolly pine, and one hardwood, a hybrid polar. Adhesive penetration depth was measured with two separate calculations, and results were compared with 2D fluorescent micrographs. A total of 54 XCT scans were collected, representing six replicates of each treatment type; each replicate, however, consisted of approximately 1500 individual, cross-section slices stacked along the specimen length. As these adhesives were highly modified, the presented results do not indicate typical behavior for their broader adhesive classes. Still, clear penetration differences were observed between each adhesive type, and between wood species bonded with both the PF and pMDI adhesives. Furthermore, penetration results depended on the calculation method used. Two adhesive types with noticeably different resin distributions in the cured bondline, showed relatively similar penetration depths when calculated with a traditional effective penetration equation. However, when the same data was calculated with a weighted penetration calculation, which accounts for both adhesive area and depth, the results appeared to better represent the different distributions depicted in the photomicrographs and tomograms. Additionally, individual replicate comparisons showed variation due to specimen anatomy, not easily observed or interpreted from 2D images. Finally, 3D views of segmented 3D adhesive phases offered unique, in-situ views of the cured adhesive structures. In particular, voids formed by CO 2 bubbles generated during pMDI cure were clearly visible in penetrated columns of the solidified adhesive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Fabrication of Two-Dimensional Rotating-Lattice Single Crystal

A rotating lattice single (RLS) crystal is a unique form of solid, which was fabricated recently as one-dimensional architecture in glass via solid state transformation induced by laser irradiation. In these objects, the lattice rotates gradually and predictably about an axis that lies in the plane of the crystal and is normal to the laser scanning direction. This paper reports on the fabrication of Sb 2 S 3 two-dimensional (2D) RLS crystals on the surface of 16SbI 3 -84Sb 2 S 3 glass, as a model example: individual RLS crystal lines are joined together using "stitching" or "rastering" as two successful protocols. The electron back scattered diffraction mapping and scanning Laue X-ray microdiffraction of the 2D RLS crystals show gradual rotation of lattice comprising of two components, one along the length of each line and another normal to this direction. The former component is determined by the rotation of the first line of the 2D pattern, but the relative contribution of the last component depends on the extent of overlap between two successive lines. By the appropriate choice of initial seed orientation and the direction of scanning, it is possible to control the lattice rotation, and even to reduce it down to 5 for a 50 × 50 μm 2 2D pattern of Sb 2 S 3 crystal.

36 MATERIALS SCIENCE↗

Variable voltage electron microscopy: Toward atom-by-atom fabrication in 2D materials

The precisely focused electron beam (e-beam) in scanning transmission electron microscopy has been found to be a versatile tool for patterning matter on the atomic level and enabling atom-by-atom fabrication, however, beam-induced phenomena are known to be extremely sensitive to the e-beam energy and are closely correlated with the proximity of the knock-on threshold. Here we provide a method to control the energy transferred to the sample while facilitating much faster changes in accelerating voltages by maintaining a nearly constant temperature in the electron microscope lenses. We use this method to demonstrate in-situ nano-milling of a graphene film followed rapidly by “gentler” imaging at lower energy. Additionally, the insertion and controlled movement of silicon dopants in graphene is demonstrated by employing a different e-beam energy during each process. We believe the incorporation of variable e-beam energy will broaden the potential for atomic scale e-beam fabrication.

36 MATERIALS SCIENCE↗

A New Geometric Method Based on Two-Dimensional Transmission Electron Microscopy for Analysis of Interior versus Exterior Pd Loading on Hollow Carbon Nanofibers

Hallow carbon nanofibers (CNFs) are being explored as catalyst supports because of their unique properties; catalytic activities with both interior and exterior metal loadings are being evaluated. Electron tomography (3D transmission electron microscopy, 3D TEM) has been used to estimate internal versus external loading of metal nanoclusters. However, this method is time consuming and requires a specialized TEM. We prepared three hollow CNF supported Pd samples with various Pd localizations, and developed a geometric analysis method based on 2D TEM images to estimate Pd internal versus external loading percentages. Results show the similar localization for the same sample in terms of the number, surface area, and mass of Pd nanoclusters but distinct values for different samples. To test our method, we compare results for one segment of a CNF using both 3D scanning transmission electron microscopy (3D TEM) and our new 2D geometic analysis method. Agreement is within 15.1%. Our results also agree with 3D TEM results from the literature for similarly prepared Pd on CNFs (within 5.6%). Our geometric analysis method is proposed as a more straightforward and fast way to evaluate metal nanocluster localizations on tubular supports.

2D↗

Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.

60 APPLIED LIFE SCIENCES↗

Electron Beam-Induced Phase Transformations in Different Crystal Orientations of a 2D van der Waals Magnet

To control materials properties at the nanoscale, the well-focused electron beam of the scanning transmission electron microscope (STEM) can be used as a tool to engineer structure with atomic precision. For 2D magnets, especially the highly anisotropic materials AgCrP2S6 and CrSBr, we find here that the STEM serves as a powerful tool for sculpting the arrangement of atoms, with the potential to modulate local magnetic properties.

Park, Eugene [Massachusetts Inst. of Technology (M↗

Material effects on dynamics in triple-nozzle gas-puff Z pinches

Here, the gas-puff Z pinch has a long history with myriad applications as an efficient neutron or x-ray source. Its simplicity as a load configuration makes it suitable for studying fundamental plasma physics phenomena such as instabilities and energy transport. For example, the implosion of cylindrical shells onto a fusion fuel are inherently susceptible to instability growth on their external surfaces; if such instabilities are unmitigated, then the consequences in terms of degraded performance can be substantial. Similarly, mitigating heat transport from a hot fuel to its colder surrounding container can make fusion conditions more easily achievable. Here we have conducted a systematic study of triple-nozzle (outer liner, inner liner, fuel) gas puffs using two-dimensional (2D) magnetohydrodynamic simulations to investigate the effect of load material on the relevant dynamics. Analogous to past studies on spherical blast waves and converging shock waves, a trend emerges linking increased radiative cooling, lower adiabatic index, and increased magneto-Rayleigh-Taylor instability growth. Notably, our results suggest that, for the present configuration, Ar radiates less than both Ne and Kr during the early stages of the implosion while mass is being swept up and perturbations begin to seed instability growth. Consequently, pinches with Ar on the outer surface exhibit more stable 2D behavior. Here we also present a parameter scan of thermonuclear neutron yield, Y, as a function of peak current, I pk and dopant concentration with Ne or Ar, depending on the inner liner material. Above 6 MA, our results suggest Y ∝ $I$$^{5}_{pk}$ and even substantial mixing (10% by volume) of Ne into the fuel does not drastically reduce yield, suggesting an Ar/Ne/fuel configuration may reliably achieve DD thermonuclear yields of 10 13 – 10 14 /cm in the 10–20 MA range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polished diamond X-ray lenses

High-quality bi-concave 2D focusing diamond X-ray lenses of apex-radius R = 100 µm produced via laser-ablation and improved via mechanical polishing are presented here. Both for polished and unpolished individual lenses and for stacks of ten lenses, the remaining figure errors determined using X-ray speckle tracking are shown and these results are compared with those of commercial R = 50 µm beryllium lenses that have similar focusing strength and physical aperture. For two stacks of ten diamond lenses (polished and unpolished) and a stack of eleven beryllium lenses, this paper presents measured 2D beam profiles out of focus and wire scans to obtain the beam size in the focal plane. These results are complemented with small-angle X-ray scattering (SAXS) measurements of a polished and an unpolished diamond lens. Again, this is compared with the SAXS of a beryllium lens. The polished X-ray lenses show similar figure errors to commercially available beryllium lenses. While the beam size in the focal plane is comparable to that of the beryllium lenses, the SAXS signal of the polished diamond lenses is considerably lower.

47 OTHER INSTRUMENTATION↗

SU-E-J-157: Improving the Quality of T2-Weighted 4D Magnetic Resonance Imaging for Clinical Evaluation

Purpose: To develop an imaging technique that enables us to acquire T2- weighted 4D Magnetic Resonance Imaging (4DMRI) with sufficient spatial coverage, temporal resolution and spatial resolution for clinical evaluation. Methods: T2-weighed 4DMRI images were acquired from a healthy volunteer using a respiratory amplitude triggered T2-weighted Turbo Spin Echo sequence. 10 respiratory states were used to equally sample the respiratory range based on amplitude (0%, 20%i, 40%i, 60%i, 80%i, 100%, 80%e, 60%e, 40%e and 20%e). To avoid frequent scanning halts, a methodology was devised that split 10 respiratory states into two packages in an interleaved manner and packages were acquired separately. Sixty 3mm sagittal slices at 1.5mm in-plane spatial resolution were acquired to offer good spatial coverage and reasonable spatial resolution. The in-plane field of view was 375mm × 260mm with nominal scan time of 3 minutes 42 seconds. Acquired 2D images at the same respiratory state were combined to form the 3D image set corresponding to that respiratory state and reconstructed in the coronal view to evaluate whether all slices were at the same respiratory state. 3D image sets of 10 respiratory states represented a complete 4D MRI image set. Results: T2-weighted 4DMRI image were acquired in 10 minutes which was within clinical acceptable range. Qualitatively, the acquired MRI images had good image quality for delineation purposes. There were no abrupt position changes in reconstructed coronal images which confirmed that all sagittal slices were in the same respiratory state. Conclusion: We demonstrated it was feasible to acquire T2-weighted 4DMRI image set within a practical amount of time (10 minutes) that had good temporal resolution (10 respiratory states), spatial resolution (1.5mm × 1.5mm × 3.0mm) and spatial coverage (60 slices) for future clinical evaluation.

60 APPLIED LIFE SCIENCES↗

Nano-Structured Mesoporous Silica Wires with Intra-Wire Lamellae via Evaporation-Induced Self-Assembly in Space-Confined Channels

Evaporation-induced self-assembly (EISA) of silica sol-gel ethanol-water solution mixtures with block-copolymer were studied inside uniform micro/nano channels. Nano-structured mesoporous silica wires, with various intra-wire self-assembly structures including lamellae, were prepared via EISA process but in space-confined channels with the diameter ranging from 50 nm to 200 nm. Membranes made of anodized aluminum oxide (AAO) and track-etched polycarbonate (EPC) were utilized as the arrays of space-confined channels (i.e., 50, 100, and 200-nm EPC and 200-nm AAO) for infiltration and drying of mixture solutions; these substrate membranes were submerged in mixture solutions consisting of a silica precursor, a structure-directing agent, ethanol, and water. After the substrate channels were filled with the solution under vacuum impregnation, the membrane was removed from the solution and dried in air. The silica precursor used was tetra-ethyl othosilicate (TEOS), and the structure-directing agent employed was triblock copolymer Pluronic-123 (P123). It was found that the formation of the mesoporous nanostructures in silica wires within uniform channels were significantly affected by the synthesis conditions including (1) pre-assemble TEOS aging time, (2) the evaporation rate during the vacuum impregnation, and (3) the air-dry temperature. The obtained intra-wire structures, including 2D-hexagonal rods and lamellae, were studied by scanning transmission electron microscopy (STEM). A steric hindrance effect seems to explain well the observed polymer-silica mesophase formation tailored by TEOS aging time. The evaporation effect, air-drying effect, and AAO-vs-EPC substrate effect on the mesoporous structure of the formed silica wires were also presented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗