Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Influence of Standard Image Processing of 3D X-ray Microscopy on Morphology, Topology and Effective Properties

Estimating porous media properties is a vital component of geosciences and the physics of porous media. Until now, imaging techniques have focused on methodologies to match image-derived flows or geomechanical parameters with experimentally identified values. Less emphasis has been placed on the compromise between image processing techniques and the consequences on topological and morphological characteristics and on computed properties such as permeability. The effects of some of the most popular image processing techniques (filtering and segmentation) available in open source on 3D X-ray Microscopy (micro-XRM) images are qualitatively and quantitatively discussed. We observe the impacts of various filters such as erosion-dilation and compare the efficiency of Otsu’s method of thresholding and the machine-learning-based software Ilastik for segmentation.

58 GEOSCIENCES↗

TU-H-207A-03: CT Hounsfield Unit Accuracy: Effect of Beam Hardening On Phantom and Clinical Whole-Body CT Images

Purpose: To assess the effect of beam hardening on measured CT HU values. Methods: An anthropomorphic knee phantom was scanned with the CT component of a GE Discovery 690 PET/CT scanner (120kVp, 300mAs, 40?0.625mm collimation, pitch=0.984, FOV=500mm, matrix=512?512) with four different scan setups, each of which induces different degrees of beam hardening by introducing additional attenuation media into the field of view. Homogeneous voxels representing “soft tissue” and “bone” were segmented by HU thresholding followed by a 3D morphological erosion operation which removes the non-homogenous voxels located on the interface of thresholded tissue mask. HU values of segmented “soft tissue” and “bone” were compared.Additionally, whole-body CT data with coverage from the skull apex to the end of toes were retrospectively retrieved from seven PET/CT exams to evaluate the effect of beam hardening in vivo. Homogeneous bone voxels were segmented with the same method previously described. Total In-Slice Attenuation (TISA) for each CT slice, defined as the summation of HU values over all voxels within a CT slice, was calculated for all slices of the seven whole-body CT datasets and evaluated against the mean HU values of homogeneous bone voxels within that slice. Results: HU values measured from the phantom showed that while “soft tissue” HU values were unaffected, added attenuation within the FOV caused noticeable decreases in the measured HU values of “bone” voxels. A linear relationship was observed between bone HU and TISA for slices of the torso and legs, but not of the skull. Conclusion: Beam hardening effect is not an issue of concern for voxels with HU in the soft tissue range, but should not be neglected for bone voxels. A linear relationship exists between bone HU and the associated TISA in non-skull CT slices, which can be exploited to develop a correction strategy.

60 APPLIED LIFE SCIENCES↗

Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are then aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel segment quality. The performance of our automated method was evaluated by comparing the automatically identified best-quality segments identified by the computer to those selected by the observers. Results: For the 20 test cases, 254 groups of corresponding vessel segments were identified after multiple phase registration and recursive matching. The AI-BQ segments agreed with the radiologist’s top 2 ranked segments in 78.3% of the 254 groups (Cohen’s kappa 0.60), and with the 4 nonradiologist observers in 76.8%, 84.3%, 83.9%, and 85.8% of the 254 groups. In addition, 89.4% of the AI-BQ segments agreed with at least two observers’ top 2 rankings, and 96.5% agreed with at least one observer’s top 2 rankings. In comparison, agreement between the four observers’ top ranked segment and the radiologist’s top 2 ranked segments were 79.9%, 80.7%, 82.3%, and 76.8%, respectively, with kappa values ranging from 0.56 to 0.68. Conclusions: The performance of our automated method for selecting the best-quality coronary segments from a multiple-phase cCTA acquisition was comparable to the selection made by human observers. This study demonstrates the potential usefulness of the automated method in clinical practice, enabling interpreting physicians to fully utilize the best available information in cCTA for diagnosis of coronary disease, without requiring manual search through the multiple phases and minimizing the variability in image phase selection for evaluation of coronary artery segments across the diversity of human readers with variations in expertise.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconstruction of 3D Concrete Microstructures Combining High-Resolution Characterization and Convolutional Neural Network for Image Segmentation

After water, concrete is the second most used material in the world. Concrete’s forming adaptability and low-cost constituents make it a predominant material used in the construction of civil infrastructures in nuclear power plants such as concrete biological shields, containment buildings, turbine buildings, fuel handling and storage buildings, underground piping for cooling, cooling towers, and so on. Depending on environmental and operating conditions, these passive structures are subject to time-dependent phenomena that can either enhance (e.g., continued hydration) or degrade concrete’s structural performance. Unlike components such as the reactor pressure vessel and the primary circuit, concrete composition varies regionally because it is manufactured using local aggregates and cement. Hence, concrete performance metrics over time cannot be derived confidently using empirical relations. Alternatively, the specific characteristics of the local concrete constituents and their assemblage in concrete must be considered.

36 MATERIALS SCIENCE↗

A New Geometric Method Based on Two-Dimensional Transmission Electron Microscopy for Analysis of Interior versus Exterior Pd Loading on Hollow Carbon Nanofibers

Hallow carbon nanofibers (CNFs) are being explored as catalyst supports because of their unique properties; catalytic activities with both interior and exterior metal loadings are being evaluated. Electron tomography (3D transmission electron microscopy, 3D TEM) has been used to estimate internal versus external loading of metal nanoclusters. However, this method is time consuming and requires a specialized TEM. We prepared three hollow CNF supported Pd samples with various Pd localizations, and developed a geometric analysis method based on 2D TEM images to estimate Pd internal versus external loading percentages. Results show the similar localization for the same sample in terms of the number, surface area, and mass of Pd nanoclusters but distinct values for different samples. To test our method, we compare results for one segment of a CNF using both 3D scanning transmission electron microscopy (3D TEM) and our new 2D geometic analysis method. Agreement is within 15.1%. Our results also agree with 3D TEM results from the literature for similarly prepared Pd on CNFs (within 5.6%). Our geometric analysis method is proposed as a more straightforward and fast way to evaluate metal nanocluster localizations on tubular supports.

2D↗

Automated segmentation of cerebral vasculature with aneurysms in 3DRA and TOF-MRA using geodesic active regions: An evaluation study

Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D x-ray reconstruction angiography (3DRA) and time of flight magnetic resonance angiography (TOF-MRA) images available in the clinical routine. Methods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols, and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using different imaging equipment. Evaluation included qualitative and quantitative analyses of the segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: isointensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an intermodality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE differed from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatability of GAR was superior to manual measurements and ISE. The intermodality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine.

60 APPLIED LIFE SCIENCES↗

Semiautomatic segmentation of liver metastases on volumetric CT images

Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation method.

60 APPLIED LIFE SCIENCES↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system

Purpose: Scanning beam digital x-ray (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis at multiple planes. This study describes a tomosynthesis-based method for 3D tracking of high-contrast objects and present the first experimental investigation of cardiac catheter tracking using a prototype SBDX system. Methods: The 3D tracking algorithm utilizes the stack of regularly spaced tomosynthetic planes that are generated by SBDX after each frame period (15 frames/s). Gradient-filtered versions of the image planes are generated, the filtered images are segmented into object regions, and then a 3D coordinate is calculated for each object region. Two phantom studies of tracking performance were conducted. In the first study, an ablation catheter in a chest phantom was imaged as it was pulled along a 3D trajectory defined by a catheter sheath (10, 25, and 50 mm/s pullback speeds). SBDX tip tracking coordinates were compared to the 3D trajectory of the sheath as determined from a CT scan of the phantom after the registration of the SBDX and CT coordinate systems. In the second study, frame-to-frame tracking precision was measured for six different catheter configurations as a function of image noise level (662-7625 photons/mm{sup 2} mean detected x-ray fluence at isocenter). Results: During catheter pullbacks, the 3D distance between the tracked catheter tip and the sheath centerline was 1.0{+-}0.8 mm (mean {+-}one standard deviation). The electrode to centerline distances were comparable to the diameter of the catheter tip (2.3 mm), the confining sheath (4 mm outside diameter), and the estimated SBDX-to-CT registration error ({+-}0.7 mm). The tip position was localized for all 332 image frames analyzed and 83% of tracked positions were inside the 3D sheath volume derived from CT. The pullback speeds derived from the catheter trajectories were within 5% of the programed pullback speeds. The tracking precision of ablation and diagnostic catheter tips ranged from {+-}0.2 mm at the highest image fluence to {+-}0.9 mm at the lowest fluence. Tracking precision depended on image fluence, the size of the tracked catheter electrode, and the contrast of the electrode. Conclusions: High speed multiplanar tomosynthesis with an inverse geometry x-ray fluoroscopy system enables 3D tracking of multiple high-contrast objects at the rate of fluoroscopic imaging. The SBDX system is capable of tracking electrodes in standard cardiac catheters with approximately 1 mm accuracy and precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of recoil-imaging time projection chambers to directional neutron background measurements in the SuperKEKB accelerator tunnel

Gaseous time projection chambers (TPCs) with high readout segmentation are capable of reconstructing detailed 3D ionization distributions of nuclear recoils resulting from elastic neutron scattering. Here, using a system of six compact TPCs with pixel ASIC readout, filled with a 70:30 mixture of He:CO 2 gas, we analyze the first directional measurements of beam-induced neutron backgrounds in the tunnel regions surrounding the Belle II detector at the SuperKEKB e + e – collider. With the use of 3D recoil tracking, we show that these TPCs are capable of maintaining nearly 100% nuclear recoil purity to reconstructed ionization energies (E reco ) as low as 5 keV ee . Using a large sample of Monte-Carlo (MC)-simulated 4 He, 12 C, and 16 O recoil tracks, we find consistency between predicted and measured recoil energy spectra in five of the six TPCs, providing useful validation of the neutron production mechanisms modeled in simulation. Restricting this sample to 4 He recoil tracks with E reco > 40 keV ee , we further demonstrate axial angular resolutions within 8° and we introduce a procedure that under suitable conditions, correctly assigns the vector direction to 91% of these simulated 4 He recoils. Applying this procedure to assign vector directions to measured 4 He recoil tracks, we observe consistency between the angular distributions of observed and simulated recoils, providing first experimental evidence of localized neutron “hotspots” in the accelerator tunnel. Observed rates of nuclear recoils in these TPCs suggest that simulation overestimates the neutron flux from these hotspots. Despite this, we estimate these hotspots to produce the majority of neutron backgrounds in the accelerator tunnel at SuperKEKB’s target luminosity of 6.3 x 10 35 cm –2 s –1 , making them important regions to continue to monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volumetric Segmentation via Neural Networks Improves Neutron Crystallography Data Analysis

Crystallography is the powerhouse technique for molecular structure determination, with applications in fields ranging from energy storage to drug design. Accurate structure determination, however, relies partly on determining the precise locations and integrated intensities of Bragg peaks in the resulting data. Here, we describe a method for Bragg peak integration that is accomplished using neural networks. The network is based on a U-Net and identifies peaks in three-dimensional reciprocal space through segmentation, allowing prediction of the full 3D peak shape from noisy data that is commonly difficult to process. The procedure for generating appropriate training sets is detailed. Trained networks achieve Dice coefficients of 0.82 and mean IoUs of 0.69. Carrying out integration over entire datasets, it is demonstrated that integrating neural network-predicted peaks results in improved intensity statistics. Furthermore, using a second dataset, the possibility of transfer learning between datasets is shown. Given the ubiquity and growing complexity of crystallography, we anticipate integration by machine learning to play an increasingly important role across the physical sciences. These early results demonstrate the applicability of deep learning techniques for integrating crystallography data and suggest a possible role in the next generation of crystallography experiments.

Sullivan, Brendan T.↗

Validation for 2D/3D registration I: A new gold standard data set

Purpose: In this article, the authors propose a new gold standard data set for the validation of two-dimensional/three-dimensional (2D/3D) and 3D/3D image registration algorithms. Methods: A gold standard data set was produced using a fresh cadaver pig head with attached fiducial markers. The authors used several imaging modalities common in diagnostic imaging or radiotherapy, which include 64-slice computed tomography (CT), magnetic resonance imaging using Tl, T2, and proton density sequences, and cone beam CT imaging data. Radiographic data were acquired using kilovoltage and megavoltage imaging techniques. The image information reflects both anatomy and reliable fiducial marker information and improves over existing data sets by the level of anatomical detail, image data quality, and soft-tissue content. The markers on the 3D and 2D image data were segmented using ANALYZE 10.0 (AnalyzeDirect, Inc., Kansas City, KN) and an in-house software. Results: The projection distance errors and the expected target registration errors over all the image data sets were found to be less than 2.71 and 1.88 mm, respectively. Conclusions: The gold standard data set, obtained with state-of-the-art imaging technology, has the potential to improve the validation of 2D/3D and 3D/3D registration algorithms for image guided therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-A-12A-07: CT-Based Biomarkers to Characterize Lung Lesion: Effects of CT Dose, Slice Thickness and Reconstruction Algorithm Based Upon a Phantom Study

Purpose: Radiogenomics promises the ability to study cancer tumor genotype from the phenotype obtained through radiographic imaging. However, little attention has been paid to the sensitivity of image features, the image-based biomarkers, to imaging acquisition techniques. This study explores the impact of CT dose, slice thickness and reconstruction algorithm on measuring image features using a thorax phantom. Methods: Twentyfour phantom lesions of known volume (1 and 2mm), shape (spherical, elliptical, lobular and spicular) and density (-630, -10 and +100 HU) were scanned on a GE VCT at four doses (25, 50, 100, and 200 mAs). For each scan, six image series were reconstructed at three slice thicknesses of 5, 2.5 and 1.25mm with continuous intervals, using the lung and standard reconstruction algorithms. The lesions were segmented with an in-house 3D algorithm. Fifty (50) image features representing lesion size, shape, edge, and density distribution/texture were computed. Regression method was employed to analyze the effect of CT dose, slice of thickness and reconstruction algorithm on these features adjusting 3 confounding factors (size, density and shape of phantom lesions). Results: The coefficients of CT dose, slice thickness and reconstruction algorithm are presented in Table 1 in the supplementary material. No significant difference was found between the image features calculated on low dose CT scans (25mAs and 50mAs). About 50% texture features were found statistically different between low doses and high doses (100 and 200mAs). Significant differences were found for almost all features when calculated on 1.25mm, 2.5mm, and 5mm slice thickness images. Reconstruction algorithms significantly affected all density-based image features, but not morphological features. Conclusions: There is a great need to standardize the CT imaging protocols for radiogenomics study because CT dose, slice thickness and reconstruction algorithm impact quantitative image features to various degrees as our study has shown.

60 APPLIED LIFE SCIENCES↗

Science Target Assessment for Mars Rover Instrument Deployment

This paper introduces the system being developed at NASA Ames Research Center, intended for the Mars '09 Smart Lander, to robustly place sensors or tools against rocks in a single communications cycle. Science targets must be assessed prior to instrument placement in order to segment them from the background and determine where, if possible, to position the instrument. An initial result of this research effort is a novel Bayesian based method for segmenting rocks from the ground using 3D data.

Pedersen, Liam↗

Intracranial Effects of Artificial Gravity: A 3T MRI Study

INTRODUCTION Spaceflight associated neuro-ocular syndrome (SANS) is characterized by the development of optic disc edema, posterior globe flattening, choroidal/retinal folds and hyperopic refractive errors1. SANS is hypothesized to be a result of headward fluid shifts that invariably occurs in the microgravity environment. As a countermeasure, artificial gravity (AG) through centrifugation has been proposed to reduce this headward fluid shift, however there is no current proof of benefit. The goal of this study was to determine if the application of AG can prevent or reduce known changes in brain volumetry, internal carotid artery (ICA) stroke volume and cerebral spinal fluid (CSF) flow velocity that occurs during simulated chronic headward fluid shift using head down tilt bed rest (HDTBR) methodology2 as an indicator of countermeasure efficacy. METHODS Healthy volunteers were recruited for an IRB approved HDTBR study performed at the German Aerospace Center in Cologne, Germany. Strict six-degree HDTBR was used as a spaceflight analog to induce a continuous headward fluid shift. HDTBR was carried out for 60 days for all subjects. Short-arm centrifugation was utilized to generate AG equating to ~0.3g of acceleration at the level of the eye. The subjects were divided equally into three groups: NoAG (control; n=8), daily intermittent AG (6 x 5 min iAG; n=8), and daily continuous 30 min (cAG; n=8). All studies were performed on a single dedicated 3T MRI Scanner. Pulse-gated MRI phase-contrast flow imaging was used to quantify ICA stroke volume and peak-to-peak CSF flow velocity in the mid cerebral aqueduct. 3D-SPGR was acquired for volumetric segmentation of the brain and CSF spaces. MRI acquisitions were obtained at baseline (BDC), 14 days into HDTBR (HDTBR14), 52 days into HDTBR (HDTBR52) and 3-5 days after HDTBR (recovery, R+3/5).The data were analyzed by the mixed model, which included intervention and time (BDC, HDTBR 14, HDTBR 52, R+3/5) as the fixed effects and included subject as the random effect.RESULTS24 healthy subject volunteers (16 men, 8 women, mean age = 33 years ± 9 [standard deviation] and mean BMI = 24.3 kg/m2 ± 2.0) successfully completed all phases of the study. Strict six-degree HDTBR was characterized by progressive and statistically significant (p<.01) increases in mean combined brain and CSF volumes and mean aqueductal CSF peak-to-peak flow velocity, as well as statistically significant (p<.01) progressive decrease in mean ICA stroke volume from baseline to 52 days post intervention (Figs. 1-3). Compared to baseline, only combined brain and CSF volumes did not return to baseline values in the recovery period (p=NS). Neither iAG nor cAG exerted any significant effects on the measured MRI brain parameters as compared to HDTBR alone (p=NS). CONCLUSION Our results indicate that HDTBR at 6-degrees was effective in producing alterations in ICA stroke volume, aqueductal CSF flow velocity, and combined brain and CSF volumetric change that is associated with chronic headward fluid shift. Short duration, 30-min daily exposure to either iAG or cAG appears to be insufficient in preventing or reducing the effects of chronic HDTBR and thus may not be a suitable countermeasure as currently deployed. AG protocol modifications, including increased duration and magnitude of exposure, should be considered for future research.

L A Kramer↗

Beam Dynamics Simulations in Project X RFQ with CST Studio Suite

Typically the RFQs are designed using the Parmteq, DesRFQ and other similar specialized codes, which produces the files containing the field and geometrical parameters for every cell. The beam dynamic simulations with these analytical fields a re, of course, ideal realizations of the designed RFQs. The new advanced computing capabilities made it possible to simulate beam and even dark current in the realistic 3D electromagnetic fields in the RFQs that may reflect cavity tuning, presence of tune rs and couplers, RFQ segmentation etc. The paper describes the utilization of full 3D field distribution obtained with CST Studio Suite for beam dynamic simulations using both PIC solver of CST Particle Studio and the beam dynamic code TRACK.

43 PARTICLE ACCELERATORS↗

Progress Update on Segmentation of Neutron Tomographic Images, 2018

The present report documents the techniques developed to segment fast-neutron tomographic images of objects consisting of assemblies of machined parts with distinct boundaries. This report satisfies the fiscal year 2018 technical deliverable for project OR16-3DTomography-PD3Jb, “3D Tomography and Image Processing Using Fast Neutrons,” to report on the extension of geometric shape-finding algorithms to three dimensions. The project has two overall goals. The first of these goals is to extend associated-particle fast-neutron transmission and, particularly, induced-reaction tomographic imaging algorithms to three dimensions. This aspect of the project is beyond the scope of this report. The second goal is to automatically segment the resultant tomographic images into constituent parts and then extract information about the parts, such as the class of shape and potentially the shape parameters. This report describes progress for the image segmentation part of the project. Imaging techniques have been developed as high-confidence methods for confirming the presence and configuration of special nuclear materials (SNM). This high confidence is achieved at the cost of revealing considerable information that may be undesirable to share with the operator of the equipment. One potential way to make use of the high-confidence of imaging methods without revealing imaging data is to employ automated analysis that can extract meaningful attributes of the SNM without showing imaging data to the operator. An essential step of this automated analysis is the segmentation of the image into its constituent parts. For example, a three-dimensional (3D) fast-neutron tomographic image of an assembly containing uranium could be reconstructed and then segmented into discrete parts. The properties of a constituent part identified as uranium would be of interest and could be extracted. For instance, the volume and density of the part would together determine its mass. Moreover, its shape might be expected to fall into a particular geometric class, such as a cube, cylinder, or sphere, and the parameters of the shape (such as side length, height, or diameter) would be expected to fall in a given range. In such an analysis, automated identification of the boundaries and properties of the uranium part is an essential step. A key goal of the present work is to infer the boundaries of objects in fast-neutron tomographic images via the general method of image segmentation. Development of this capability can be broken into more manageable steps, including 1. operator-guided segmentation of two-dimensional (2D) fast-neutron tomographic images, 2. operator-guided segmentation of 3D fast-neutron tomographic images, 3. development of automated segmentation algorithms, and 4. extraction of shape parameters from constituent volumes in 3D. In the first year, the project team reported progress on the first step. Last year, progress on the second step, the extension into 3D, was reported with application to simulated data. The present report describes additional progress on the second step, and progress toward the third step, automated segmentation algorithms. In particular, a multiphase level set approach for image segmentation in three dimensions has been applied to measured 3D data for the first time. Activities related to the fourth step will also be reported, but it will focus on estimation of 3D volumes rather than shape parameters. In this report, the steps before image segmentation will be described, and the multiphase level sets approach to image segmentation will be briefly reviewed. This will be followed by a discussion of the issues encountered when applying the level set technique to measured 3D transmission images, and then a description of the inclusion of induced-reaction data will be provided. Finally, segmentation results for various measured target assemblies will be presented and the image segmentation portion of this project will be summarized and future directions will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Juxtatumoral perinephric fat analysis in clear cell renal cell carcinoma

Purpose: The purpose of the study was to evaluate the feasibility of using contrast-enhanced computed tomography (CECT)-based texture analysis (CTTA) metrics to differentiate between juxtatumoral perinephric fat (JPF) surrounding low-grade (ISUP 1–2) versus high-grade (ISUP 3–4) clear cell renal cell carcinoma (ccRCC). Methods: In this IRB-approved study, we retrospectively queried the surgical database between June 2009 and April 2016 and identified 83 patients with pathologically confirmed ccRCC (low grade: n = 54, mean age = 61.5 years, 18F/35M; high grade n = 30, mean age = 61.7 years, 8F/22M) who also had pre-operative multiphase CT acquisitions. CT images were transferred to a 3D workstation, and nephrographic phase JPF regions were manually segmented. Using an in-house developed Matlab program, a CTTA panel comprising of texture metrics extracted using six different methods, histogram, 2D- and 3D-Gray-level co-occurrence matrix (GLCM) and Gray-level difference matrix (GLDM), and 2D-Fast Fourier Transform (FFT) analyses, was applied to the segmented images to assess JPF textural heterogeneity in low- versus high-grade ccRCC. Univariate analysis and receiver-operator characteristics (ROC) analysis were used to assess interclass differences in texture metrics and their prediction accuracy, respectively. Results: All methods except GLCM consistently revealed increased heterogeneity in the JPF surrounding high- versus low-grade ccRCC. FFT showed increased complexity index (p < 0.01). Histogram analysis showed increased kurtosis and positive skewness in (p < 0.03), and GLDM analysis showed decreased measure of correlation coefficient (MCC) (p < 0.04). Several of the GLCM metrics showed statistically significant (p < 0.04) textural differences between the two groups, but with no consistent trend. ROC analysis showed that MCC in GLCM analysis had an area under the curve of 0.75. Conclusions: Our study suggests that CTTA of ccRCC shows statistically significant textural differences in JPF surrounding high- versus low-grade ccRCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗