Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACOUSTIC SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

ANGULAR MOMENTUM TRANSPORT BY ACOUSTIC MODES GENERATED IN THE BOUNDARY LAYER. II. MAGNETOHYDRODYNAMIC SIMULATIONS

We perform global unstratified three-dimensional magnetohydrodynamic simulations of an astrophysical boundary layer (BL)-an interface region between an accretion disk and a weakly magnetized accreting object such as a white dwarf-with the goal of understanding the effects of magnetic field on the BL. We use cylindrical coordinates with an isothermal equation of state and investigate a number of initial field geometries including toroidal, vertical, and vertical with zero net flux. Our initial setup consists of a Keplerian disk attached to a non-rotating star. In a previous work, we found that in hydrodynamical simulations, sound waves excited by shear in the BL were able to efficiently transport angular momentum and drive mass accretion onto the star. Here we confirm that in MHD simulations, waves serve as an efficient means of angular momentum transport in the vicinity of the BL, despite the magnetorotational instability (MRI) operating in the disk. In particular, the angular momentum current due to waves is at times larger than the angular momentum current due to MRI. Our results suggest that angular momentum transport in the BL and its vicinity is a global phenomenon occurring through dissipation of waves and shocks. This point of view is quite different from the standard picture of transport by a local anomalous turbulent viscosity. In addition to angular momentum transport, we also study magnetic field amplification within the BL. We find that the field is indeed amplified in the BL, but only by a factor of a few, and remains subthermal.

79 ASTRONOMY AND ASTROPHYSICS↗

A particle-in-cell approach to obliquely propagating electrostatic waves

The electron-acoustic and beam-driven modes associated with electron beams have previously been identified and studied numerically. These modes are associated with Broadband Electrostatic Noise found in the Earth's auroral and polar cusp regions. Using a 1-D spatial Particle-in-Cell simulation, the electron-acoustic instability is studied for a magnetized plasma, which includes cool ions, cool electrons and a hot, drifting electron beam. Both the weakly and strongly magnetized regimes with varying wave propagation angle, θ, with respect to the magnetic field are studied. The amplitude and frequency of the electron-acoustic mode are found to decrease with increasing θ. The amplitude of the electron-acoustic mode is found to significantly grow at intermediate wavenumber ranges. It reaches a saturation level at the point, where a plateau forms in the hot electron velocity distribution after which the amplitude of the electron-acoustic mode decays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utilizing a Novel Acoustic Backscatter Array to Characterize Waste Consolidation and Settling in a Horizontal Flow Clarifier - 16051

As part of a collaboration between the University of Leeds, Sellafield Ltd and MMI Engineering Ltd, bespoke acoustic instrumentation and numerical simulation methods have been established to optimize nuclear legacy waste transfers. Specifically, a new ultrasonic measurement system has been developed, allowing suspended particle concentration and consolidation to be measured remotely. This technology has been combined with computational fluid dynamics (CFD) modelling of settling particulate systems, permitting full characterization, simulation and prediction of sludge separation processes. Presented here are experimental and numerical results on the transport and settling behavior of non-active nuclear-analogue suspensions in two flow geometries: gravitational settling of glass dispersions in a 250-liter column; and transport and sedimentation of flocculated calcite in a close-to-full-scale clarifier (9 m{sup 3} total volume and 4.8 m{sup 2} length). In addition, details of the design, construction and calibration of a custom-built Ultrasonic Array Research Platform (UARP) are described. Settling column results suggested that particle concentration changes could be simulated with good accuracy by a CFD model (developed using the open source OpenFOAM framework) when compared to measured samples. Large-scale clarifier trials were used to assess the effectiveness of the UARP controller with an attached in situ acoustic backscatter array (ABA). The ABA consisted of 8 transducers angled down at 20 deg. to the vertical, pulsing at 2-2.5 MHz in cycles (covering 1.8 m total depth). In comparison to a range of sampled concentrations across the length of the clarifier, results confirmed that the UARP-ABA system was highly successful at characterizing these complex flows over several hours of operation, allowing visualization of depth-wise bulk density changes and bed build-up over time. Collectively, this work highlights the capability of these tools to monitor and optimize a number of current waste transfer operations at Sellafield, with further potential applications for solid-liquid separations across waste, water treatment and minerals engineering industries. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification of the helioseismology travel-time measurement technique and the inversion procedure for sound speed using artificial data

We performed three-dimensional numerical simulations of the solar surface acoustic wave field for the quiet Sun and for three models with different localized sound-speed perturbations in the interior with deep, shallow, and two-layer structures. We used the simulated data generated by two solar acoustics codes that employ the same standard solar model as a background model, but utilize different integration techniques and different models of stochastic wave excitation. Acoustic travel times were measured using a time-distance helioseismology technique, and compared with predictions from ray theory frequently used for helioseismic travel-time inversions. It is found that the measured travel-time shifts agree well with the helioseismic theory for sound-speed perturbations, and for the measurement procedure with and without phase-speed filtering of the oscillation signals. This testing verifies the whole measuring-filtering-inversion procedure for static sound-speed anomalies with small amplitude inside the Sun outside regions of strong magnetic field. It is shown that the phase-speed filtering, frequently used to extract specific wave packets and improve the signal-to-noise ratio, does not introduce significant systematic errors. Results of the sound-speed inversion procedure show good agreement with the perturbation models in all cases. Due to its smoothing nature, the inversion procedure may overestimate sound-speed variations in regions with sharp gradients of the sound-speed profile.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic Carrier Modulation via Nonlinear Acoustoelectric Transport in van der Waals Heterostructures

Dynamically manipulating carriers in van der Waals heterostructures could enable solid-state quantum simulators with tunable lattice parameters. A key requirement is the formation of deep potential wells to reliably trap excitations. Here, we report the observation of nonlinear acoustoelectric transport and dynamic carrier modulation in boron nitride-encapsulated graphene devices coupled to intense surface acoustic waves (SAWs) on LiNbO 3 substrates. SAWs generate strong acoustoelectric current densities ( J AE ), transitioning from linear to nonlinear regimes with increasing SAW intensity. In the nonlinear regime, periodic carrier (electrons, holes, or their mixtures) stripes emerge. Using counter-propagating SAWs, we create standing SAWs (SSAWs) to dynamically manipulate charge distributions without static gates. The saturation of J AE , attenuation transitions, and tunable resistance peaks confirms strong carrier localization. Finally, these results establish SAWs as a powerful tool for controlling carrier dynamics in two-dimensional (2D) materials, paving the way for the development of time-dependent quantum systems and acoustic lattices for quantum simulation.

2D materials↗

Quasi-Distributed Fiber Sensor-Based Approach for Pipeline Health Monitoring: Generating and Analyzing Physics-Based Simulation Datasets for Classification

This study presents a framework for detecting mechanical damage in pipelines, focusing on generating simulated data and sampling to emulate distributed acoustic sensing (DAS) system responses. The workflow transforms simulated ultrasonic guided wave (UGW) responses into DAS or quasi-DAS system responses to create a physically robust dataset for pipeline event classification, including welds, clips, and corrosion defects. This investigation examines the effects of sensing systems and noise on classification performance, emphasizing the importance of selecting the appropriate sensing system for a specific application. The framework shows the robustness of different sensor number deployments to experimentally relevant noise levels, demonstrating its applicability in real-world scenarios where noise is present. Overall, this study contributes to the development of a more reliable and effective method for detecting mechanical damage to pipelines by emphasizing the generation and utilization of simulated DAS system responses for pipeline classification efforts. The results on the effects of sensing systems and noise on classification performance further enhance the robustness and reliability of the framework.

36 MATERIALS SCIENCE↗

Electrochemical-acoustic time of flight: in operando correlation of physical dynamics with battery charge and health

We demonstrate that a simple acoustic time-of-flight experiment can measure the state of charge and state of health of almost any closed battery. An acoustic conservation law model describing the state of charge of a standard battery is proposed, and experimental acoustic results verify the simulated trends; furthermore, a framework relating changes in sound speed, via density and modulus changes, to state of charge and state of health within a battery is discussed. Regardless of the chemistry, the distribution of density within a battery must change as a function of state of charge and, along with density, the bulk moduli of the anode and cathode changes as well. The shifts in density and modulus also change the acoustic attenuation in a battery. Experimental results indicating both state-of-charge determination and irreversible physical changes are presented for two of the most ubiquitous batteries in the world, the lithium-ion 18650 and the alkaline LR6 (AA). Overall, a one-or two-point acoustic measurement can be related to the interaction of a pressure wave at multiple discrete interfaces within a battery, which in turn provides insights into state of charge, state of health, and mechanical evolution/degradation.

Hsieh, AG↗

Final Report on the Viability of Acoustic Techniques for Density and Mass Flow in Enrichment Plants

The primary purpose of this research is to study the viability of acoustic signatures and sensors that could support accurate, noninvasive, and unattended measurement of uranium hexafluoride (UF6) gas density and mass flow rate in situations representative of gaseous centrifuge enrichment plants (GCEP) under safeguards by the International Atomic Energy Agency. The measurement method under development can be readily retrofitted to the exterior of piping in existing systems, potentially facilitating acceptance by facility operators. The findings from the demonstration of a preliminary prototype design and first-generation analysis algorithms in this project will inform the safeguards community as to whether continued acoustic instrument and methods development are warranted. This project conducted two types of measurements, depending on the flow conditions of the gas. For static measurements, the focus is on understanding the acoustic properties at low pressure for non-flowing UF6. For flow measurements, the focus is on understanding the performance of the acoustic system in a simulation of a GCEP pipe using a surrogate gas under fully developed flow conditions. Testing with flowing UF6 was not considered because the cost of building a flowing UF6 system with flow similar to a GCEP was considerably greater than allocated project resources. This document summarizes the results of research conducted over the course of the project. Based on the results to date, the approach is seen to be promising with non-invasive acoustic measurements shown to be possible at the desired pressures. The project has demonstrated • 5% uncertainty of the UF6 gas density for static measurements at pressures relevant to GCEP operations over a 5-minute measurement window with a clear path forward to achieving considerably lower uncertainties over a two-hour period, • Measurements of flowing surrogate gases at pressures relevant to GCEP operations. However, additional research remains to be done to further develop the measurement approach and transition the technology for field use. These development needs include: • Understand the impact of flowing gas on gas density measurements, • Adding sensors and improving the measurement procedure, • Augmenting the data analysis methods by leveraging machine learning approaches, • Reevaluating uncertainty requirements for density and mass flow given observed Online Enrichment Monitor (OLEM) measurement uncertainties, • Designing a robust instrumentation package for field-testing, and • Evaluating measurement results to understand the potential impact on mass balance calculations within GCEP facilities.

42 ENGINEERING↗

Efficacy of Single-Suture Incision Closures in Tagged Juvenile Chinook Salmon Exposed to Simulated Turbine Passage

Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the use of a shorter incision-one that may warrant only a single suture for closure. However, it is not known whether a single suture will sufficiently hold the incision closed when fish are decompressed and when outward pressure is placed on the surgical site during turbine passage through hydroelectric dams. The objective of this study was to evaluate the effectiveness of single-suture incision closures on five response variables in juvenile Chinook salmon Oncorhynchus tshawytscha that were subjected to simulated turbine passage. An acoustic transmitter (0.43 g in air) and a passive integrated transponder tag (0.10 g in air) were implanted in each fish; the 6-mm incisions were closed with either one suture or two sutures. After exposure to simulated turbine passage, none of the fish exhibited expulsion of transmitters. In addition, the percentage of fish with suture tearing, incision tearing, or mortal injury did not differ between treatments. Expulsion of viscera through the incision was higher among fish that received one suture (12%) than among fish that received two sutures (1%). The higher incidence of visceral expulsion through single-suture incisions warrants concern. Consequently, for cases in which tagged juvenile salmonidsmay be exposed to turbine passage, we do not recommend the use of one suture to close 6-mm incisions associated with acoustic transmitter implantation.

13 HYDRO ENERGY↗

Calibrating the baryon oscillation ruler for matter and halos

We characterize the nonlinear evolution of the baryon acoustic feature as traced by the dark matter and halos, using a combination of perturbation theory and N-body simulations. We confirm that the acoustic peak traced by the dark matter is both broadened and shifted as structure forms, and that this shift is well described by second-order perturbation theory. These shifts persist for dark matter halos, and are a simple function of halo bias, with the shift (mostly) increasing with increasing bias. Extending our perturbation theory results to halos with simple two parameter bias models (both in Lagrangian and Eulerian space) quantitatively explains the observed shifts. In particular, we demonstrate that there are additional terms that contribute to the shift that are absent for the matter. At z=0 for currently favored cosmologies, the matter shows shifts of {approx}0.5%, b=1 halos shift the acoustic scale by {approx}0.2%, while b=2 halos shift it by {approx}0.5%; these shifts decrease by the square of the growth factor D(z) at higher redshifts. These results are easily generalized to galaxies within the halo model, where we show that simple galaxy models show marginally larger shifts than the correspondingly biased halos, due to the contribution of satellites in high mass halos. While our focus here is on real space, our results make specific predictions for redshift space. For currently favored cosmological models, we find that the shifts for halos at z=0 increase by {approx}0.3%; at high z, they increase by {approx}0.5%D{sup 2}. Our results demonstrate that these theoretical systematics are smaller than the statistical precision of upcoming surveys, even if one ignored the corrections discussed here. Simple modeling, along the lines discussed here, has the potential to reduce these systematics to below the levels of cosmic variance limited surveys.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Algorithms and analyses for stochastic optimization for turbofan noise reduction using parallel reduced-order modeling

Simulation-based optimization of acoustic liner design in a turbofan engine nacelle for noise reduction purposes can dramatically reduce the cost and time needed for experimental designs. Because uncertainties are inevitable in the design process, a stochastic optimization algorithm is posed based on the conditional value-at-risk measure so that an ideal acoustic liner impedance is determined that is robust in the presence of uncertainties. A parallel reduced-order modeling framework is developed that dramatically improves the computational efficiency of the stochastic optimization solver for a realistic nacelle geometry. The reduced stochastic optimization solver takes less than 500 s to execute. Additionally, well-posedness and finite element error analyses of the state system and optimization problem are provided.

97 MATHEMATICS AND COMPUTING↗

r-process in Type II supernovae and the role of direct capture

We have calculated r-process nucleosynthesis based on acoustic wave driven supernova simulation. The environment includes extremely high entropy cases which has not been studied in previous studies. Plenty of actinide and third peak elements are formed in an averaged abundance, while elements around the first and second peaks are overproduced. We also studied the effect of direct capture in r-process. The direct capture furthers r-process and make freeze out earlier. It will change the final abundance drastically. We recalculated r-process nucleosynthesis of the simulation considering the direct capture reaction. While we could not see a significant difference in averaged abundances, significant differences appeared in several individual yields.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrasonic fingerprint sensor using a piezoelectric micromachined ultrasonic transducer array integrated with complementary metal oxide semiconductor electronics

This paper presents an ultrasonic fingerprint sensor based on a 24 × 8 array of 22 MHz piezoelectric micromachined ultrasonic transducers (PMUTs) with 100 μm pitch, fully integrated with 180 nm complementary metal oxide semiconductor (CMOS) circuitry through eutectic wafer bonding. Each PMUT is directly bonded to a dedicated CMOS receive amplifier, minimizing electrical parasitics and eliminating the need for through-silicon vias. The array frequency response and vibration mode-shape were characterized using laser Doppler vibrometry and verified via finite element method simulation. The array's acoustic output was measured using a hydrophone to be ∼14 kPa with a 28 V input, in reasonable agreement with predication from analytical calculation. Pulse-echo imaging of a 1D steel grating is demonstrated using electronic scanning of a 20 × 8 sub-array, resulting in 300 mV maximum received amplitude and 5:1 contrast ratio. Because the small size of this array limits the maximum image size, mechanical scanning was used to image a 2D polydimethylsiloxane fingerprint phantom (10 mm × 8 mm) at a 1.2 mm distance from the array.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical modelling of nonlinear full-wave acoustic propagation

The various model equations of nonlinear acoustics are arrived at by making assumptions which permit the observation of the interaction with propagation of either single or joint effects. We present here a form of the conservation equations of fluid dynamics which are deduced using slightly less restrictive hypothesis than those necessary to obtain the well known Westervelt equation. This formulation accounts for full wave diffraction, nonlinearity, and thermoviscous dissipative effects. A two-dimensional, finite-volume method using Roe’s linearisation has been implemented to obtain numerically the solution of the proposed equations. This code, which has been written for parallel execution on a GPU, can be used to describe moderate nonlinear phenomena, at low Mach numbers, in domains as large as 100 wave lengths. Applications range from models of diagnostic and therapeutic HIFU, to parametric acoustic arrays and nonlinear propagation in acoustic waveguides. Examples related to these applications are shown and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency dependence of the acoustic field generated from a spherical cavity transducer with open ends

Resolution of high intensity focused ultrasound (HIFU) focusing is limited by the wave diffraction. We have developed a spherical cavity transducer with two open ends to improve the focusing precision without sacrificing the acoustic intensity (App Phys Lett 2013; 102: 204102). This work aims to theoretically and experimentally investigate the frequency dependence of the acoustic field generated from the spherical cavity transducer with two open ends. The device emits high intensity ultrasound at the frequency ranging from 420 to 470 kHz, and the acoustic field is measured by a fiber optic probe hydrophone. The measured results shows that the spherical cavity transducer provides high acoustic intensity for HIFU treatment only in its resonant modes, and a series of resonant frequencies can be choosen. Furthermore, a finite element model is developed to discuss the frequency dependence of the acoustic field. The numerical simulations coincide well with the measured results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radial properties of the geodesic acoustic mode

In magnetized toroidal plasmas, neoclassical effects and turbulent drift waves can induce the geodesic acoustic mode (GAM). We simulate the GAM using the gyro-kinetic code GTS for typical tokamak parameters and investigate its properties, especially its frequency continuum, evolution of its radial wave number, and propagation characteristics. The simulation findings are compared with those of the relevant theory and experiment. It is discovered that the radial phase velocity of the GAM is roughly proportional to the ion thermal speed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parameter estimation with Sandage-Loeb test

The Sandage-Loeb (SL) test directly measures the expansion rate of the universe in the redshift range of 2 ∼< z ∼< 5 by detecting redshift drift in the spectra of Lyman-α forest of distant quasars. We discuss the impact of the future SL test data on parameter estimation for the ΛCDM, the wCDM, and the w{sub 0}w{sub a}CDM models. To avoid the potential inconsistency with other observational data, we take the best-fitting dark energy model constrained by the current observations as the fiducial model to produce 30 mock SL test data. The SL test data provide an important supplement to the other dark energy probes, since they are extremely helpful in breaking the existing parameter degeneracies. We show that the strong degeneracy between Ω{sub m} and H{sub 0} in all the three dark energy models is well broken by the SL test. Compared to the current combined data of type Ia supernovae, baryon acoustic oscillation, cosmic microwave background, and Hubble constant, the 30-yr observation of SL test could improve the constraints on Ω{sub m} and H{sub 0} by more than 60% for all the three models. But the SL test can only moderately improve the constraint on the equation of state of dark energy. We show that a 30-yr observation of SL test could help improve the constraint on constant w by about 25%, and improve the constraints on w{sub 0} and w{sub a} by about 20% and 15%, respectively. We also quantify the constraining power of the SL test in the future high-precision joint geometric constraints on dark energy. The mock future supernova and baryon acoustic oscillation data are simulated based on the space-based project JDEM. We find that the 30-yr observation of SL test would help improve the measurement precision of Ω{sub m}, H{sub 0}, and w{sub a} by more than 70%, 20%, and 60%, respectively, for the w{sub 0}w{sub a}CDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-AB-209-08: Next Generation Dedicated 3D Breast Imaging with XACT

Purpose: Exposure to radiation increases the risk of cancer. We have designed a new imaging paradigm, X-ray induced acoustic computed tomography (XACT). Applying this innovative technology to breast imaging, an X-ray exposure can generate a 3D acoustic image, which dramatically reduces the radiation dose to patients when compared to conventional breast CT. Methods: Theoretical calculations are done to determine the appropriate X-ray energy and ultrasound frequency in breast XACT imaging. A series of breast CT image along the coronal plane from a patient with calcifications in the breast tissue are used as the source image. HU value based segmentation is done to distinguish the skin, adipose tissue, glandular tissue, breast calcification, and chest bone from each CT image. X-ray dose deposition in each pixel is calculated based on the tissue type by using GEANT4 Monte Carlo toolkits. The initial pressure rise caused by X-ray energy deposition is calculated according to tissue properties. Then, the X-ray induced acoustic wave propagation is simulated by K-WAVE toolkit. Breast XACT images are reconstructed from the recorded time-dependent ultrasound waves. Results: For imaging a breast with large size (16cm in diameter at chest wall), the photon energy of X-ray source and the central frequency of ultrasound detector is determined as 20keV and 5.5MHz. Approximately 10 times contrast between a calcification and the breast tissue can be acquire from XACT image. The calcification can be clearly identified from the reconstructed XACT image. Conclusion: XACT technique takes the advantages of X-ray absorption contrast and high ultrasonic resolution. With the proposed innovative technology, one can potentially reduce radiation dose to patient in 3D breast imaging as compared with current x-ray modalities, while still maintaining high imaging contrast and spatial resolution.

60 APPLIED LIFE SCIENCES↗