Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANOVA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Tissue Doppler Imaging Combined with Advanced 12-Lead ECG Analysis Might Improve Early Diagnosis of Hypertrophic Cardiomyopathy in Childhood

Optimization of early diagnosis of childhood hypertrophic cardiomyopathy (HCM) is essential in lowering the risk of HCM complications. Standard echocardiography (ECHO) has shown to be less sensitive in this regard. In this study, we sought to assess whether spatial QRS-T angle deviation, which has shown to predict HCM in adults with high sensitivity, and myocardial Tissue Doppler Imaging (TDI) could be additional tools in early diagnosis of HCM in childhood. Methods: Children and adolescents with familial HCM (n=10, median age 16, range 5-27 years), and without obvious hypertrophy but with heredity for HCM (n=12, median age 16, range 4-25 years, HCM or sudden death with autopsy-verified HCM in greater than or equal to 1 first-degree relative, HCM-risk) were additionally investigated with TDI and advanced 12-lead ECG analysis using Cardiax(Registered trademark) (IMED Co Ltd, Budapest, Hungary and Houston). Spatial QRS-T angle (SA) was derived from Kors regression-related transformation. Healthy age-matched controls (n=21) were also studied. All participants underwent thorough clinical examination. Results: Spatial QRS-T angle (Figure/ Panel A) and septal E/Ea ratio (Figure/Panel B) were most increased in HCM group as compared to the HCM-risk and control groups (p less than 0.05). Of note, these 2 variables showed a trend toward higher levels in HCM-risk group than in control group (p=0.05 for E/Ea and 0.06 for QRS/T by ANOVA). In a logistic regression model, increased SA and septal E/Ea ratio appeared to significantly predict both the disease (Chi-square in HCM group: 9 and 5, respectively, p less than 0.05 for both) and the risk for HCM (Chi-square in HCM-risk group: 5 and 4 respectively, p less than 0.05 for both), with further increased predictability level when these 2 variables were combined (Chi-square 10 in HCM group, and 7 in HCM-risk group, p less than 0.01 for both). Conclusions: In this small material, Tissue Doppler Imaging and spatial mean QRS-T angle deviation, particularly when combined, appear to be sensitive in predicting the risk for developing childhood HCM. Large-scale, prospective studies are needed to confirm this hypothesis.

Femlund, E.↗

VEGGIE Pillow Testing: Microbial Analysis of Cut-and-Come-Again Species Testing

With NASA focused on researching and developing technology for deep space missions, the need for a reliable supplementary food source must also be considered. For the ISS, resupplying the food source is more practical and cost effect since the facility is in low Earth orbit. However, as NASA attempts to push the frontier in space, the costs and distance for resupply will surely increase. Plants would contribute to the proportion of food and reduce the dependency on food from Earth. In addition, plants would provide oxygen production, carbon dioxide removal, and psychological benefits. As a result, a vegetable production system, VEGGIE, was developed for NASA to produce salad crops with minimal resources and study the beneficial effects. The VEGGIE pillow is a single use bag for growing crops that is used with the VEGGIE hardware. The VEGGIE pillow was tested with four different species of plants with the cut-and-come-again harvest method to determine the greatest yield. Instead of harvesting the entire plant, the harvest consisted of cutting leaves to allow the plant to regrow leaves. The harvest methods included cutting the plants weekly, bi-weekly, and monthly. A fifth plant species, radishes, was also harvested and replanted. Microbial load analysis and an ANOVA significance test were utilized. The data suggest that the two Brassica plants have the greatest yields; however, the microbial load is also greatest for the two plants per gram of fresh weight. Furthermore, the results support the reuse of pillows for multiple harvests as shown by the replanted radishes.

Nguyen, Bao-Thang↗

Muscle Adaptations Following Short-Duration Bed Rest with Integrated Resistance, Interval, and Aerobic Exercise

Unloading of the musculoskeletal system during space flight results in deconditioning that may impair mission-related task performance in astronauts. Exercise countermeasures have been frequently tested during bed rest (BR) and limb suspension; however, high-intensity, short-duration exercise prescriptions have not been fully explored. PURPOSE: To determine if a high intensity resistance, interval, and aerobic exercise program could protect against muscle atrophy and dysfunction when performed during short duration BR. METHODS: Nine subjects (1 female, 8 male) performed a combination of supine exercises during 2 weeks of horizontal BR. Resistance exercise (3 d / wk) consisted of squat, leg press, hamstring curl, and heel raise exercises (3 sets, 12 repetitions). Aerobic (6 d / wk) sessions alternated continuous (75% VO2 peak) and interval exercise (30 s, 2 min, and 4 min) and were completed on a supine cycle ergometer and vertical treadmill, respectively. Muscle volumes of the upper leg were calculated pre, mid, and post-BR using magnetic resonance imaging. Maximal isometric force (MIF), rate of force development (RFD), and peak power of the lower body extensors were measured twice before BR (averaged to represent pre) and once post BR. ANOVA with repeated measures and a priori planned contrasts were used to test for differences. RESULTS: There were no changes to quadriceps, hamstring, and adductor muscle volumes at mid and post BR time points compared to pre BR (Table 1). Peak power increased significantly from 1614 +/- 372 W to 1739 +/- 359 W post BR (+7.7%, p = 0.035). Neither MIF (pre: 1676 +/- 320 N vs. post: 1711 +/- 250 N, +2.1%, p = 0.333) nor RFD (pre: 7534 +/- 1265 N/ms vs. post: 6951 +/- 1241 N/ms, -7.7%, p = 0.136) were significantly impaired post BR.

Hackney, Kyle J.↗

Pilot Study: Unique Response of Bone Tissue During an Investigation of Radio-Adaptive Effects in Mice

PURPOSE: We obtained bone tissue to evaluate the collateral effects of experiments designed to investigate molecular mechanisms of radio-adaptation in a mouse model. Radio-adaptation describes a process by which the prior exposure to low dose radiation can protect against the toxic effect of a subsequent high dose exposure. In the radio-adaptation experiments, C57Bl/6 mice were exposed to either a Sham or a priming Low Dose (5 cGy) of Cs-137 gamma rays before being exposed to either a Sham or High Dose (6 Gy) 24 hours later. ANALYSIS: Bone tissue were obtained from two experiments where mice were sacrificed at 3 days (n=3/group, 12 total) and at 14 days (n=6/group, 24 total) following high dose exposure. Tissues were analyzed to 1) evaluate a radio-adaptive response in bone tissue and 2) describe cellular and microstructural effects for two skeletal sites with different rates of bone turnover. One tibia and one lumbar vertebrae (LV2), collected at the 3-day time-point, were analyzed by bone histomorphometry and micro-CT to evaluate the cellular response and any evidence of microarchitectural impact. Likewise, tibia and LV2, collected at the 14-day time-point, were analyzed by micro-CT alone to evaluate resulting changes to bone structure and microarchitecture. The data were analyzed by 2-way ANOVA to evaluate the effects of the priming low dose radiation, of the high dose radiation, and of any interaction between the priming low and high doses of radiation. Bone histomorphometry was performed in the cancellous bone (aka trabecular bone) compartments of the proximal tibial metaphysis and of LV2. RESULTS: Cellular Response @ 3 Days The priming Low Dose radiation decreased osteoblast-covered bone perimeter in the proximal tibia and the total cell density in the bone marrow in the LV2. High Dose radiation, regardless of prior exposure to priming dose, dramatically reduced total cell density in bone marrow of both the long bone and vertebra. However, in the proximal tibia, High Dose radiation increased the osteoclast-covered bone perimeters, the density of adipocytes in bone marrow, and the area of bone marrow occupied by fat cells -- while in the LV2, adipocytes were rare and not stimulated by High Dose radiation. In an unexpected response, High Dose radiation dramatically increased (10-fold) osteoblast-covered bone perimeter in the LV2.

Sibonga, J. D.↗

Near-Infrared Spectroscopic Measurement of the Effect of Leg Dominance on Muscle Oxygen Saturation During Cycling

The effect of leg dominance on the symmetry of the biomechanics during cycling remains uncertain -- asymmetries have been observed in kinematics and kinetics, while symmetries were found in muscle activation. No studies have yet investigated the symmetry of muscle metabolism during cycling. Near-infrared spectroscopy (NIRS) provides a non-invasive method to investigate the metabolic responses of specific muscles during cycling. PURPOSE: To determine whether there was an effect of leg dominance on thigh muscle oxygen saturation (SmO2) during incrementally loaded submaximal cycling using NIRS. METHODS: Eight right leg dominant, untrained subjects (5 men, 3 women; 31+/-2 yrs; 168.6+/-1.0 cm; 67.2+/-1.8 kg, mean +/- SE) volunteered to participate. Spectra were collected bilaterally from the vastus lateralis (VL) during supine rest and cycling. SmO2 was calculated using previously published methods. Subjects pedaled at 65 rpm while resistance to pedaling was increased in 0.5 kp increments from 0.5 kp every 3 min until the subject reached 80% of age-predicted maximal heart rate. SmO2 was averaged over 3 min for each completed stage. A two-way ANOVA was performed to test for leg differences. A priori contrasts were used to compare work levels to rest. RESULTS: VL SmO2 was not different between the dominant and non-dominant legs at rest and during exercise (p=0.57). How SmO2 changed with workload was also not different between legs (p=0.32). SmO2 at 0.5 kp (60.3+/-4.0, p=0.12) and 1.0 kp (59.5+/-4.0, p=0.10) was not different from rest (69.1+/-4.0). SmO2 at 1.5 kp (55.4 4.0, p=0.02), 2.0 kp (55.7+/-5.0, p=0.04), and 2.5 kp (43.4+/-7.9, p=0.01) was significantly lower than rest. CONCLUSION: VL SmO2 during cycling is not different between dominant and non-dominant legs and decreases with moderate workload in untrained cyclists. Assuming blood flow is directed equally to both legs, similar levels of oxygen extraction (as indicated by SmO2) suggests the metabolic load of cycling is not different between legs. This is in agreement with a recent study demonstrating symmetrical increase of muscle activation of the VL during cycling. Leg dominance did not influence VL SmO2 during submaximal cycling, but may have an effect at higher loads or during other forms of exercise, such as walking and running.

Ellerby, Gwenn E. C.↗

Retrospective Study of Serum Sclerostin Measurements in Bed Rest Subjects

Animal models and human studies suggest that osteocytes regulate the skeleton s response to mechanical unloading at the cellular level in part by an increase in sclerostin, an inhibitor of the anabolic Wnt pathway. However, few studies have reported changes in serum sclerostin in humans exposed to reduced mechanical loading. Thus, we determined changes in serum sclerostin and bone turnover markers in healthy adult men who participated in a controlled bed rest study. Seven healthy adult men (31 +/- 3 yrs old) underwent 90-day six-degree head down tilt bed rest at the University of Texas Medical Branch in Galveston's Institute for Translational Sciences - Clinical Research Center (ITS-CRC). Serum sclerostin, PTH, serum markers of bone turnover (bone specific alkaline phosphatase, RANKL/OPG, and osteocalcin), urinary calcium and phosphorus excretion, and 24 hour pooled urinary markers of bone resorption (NTX, DPD, PYD) were evaluated pre-bed rest (BL), bed rest day 28 (BR-28), bed rest day 60 (BR-60), and bed rest day 90 (BR-90). In addition, bone mineral density (BMD) was assessed by dual-energy X-ray absorptiometry (DXA) at BL, BR-60, and post bed rest day 5 (BR+5). Data are reported as mean +/- standard deviation. We used repeated measures ANOVA to compare baseline values to BR-28, BR-60, and BR-90. RESULTS Consistent with prior reports, BMD declined significantly (1-2% per month) at weight-bearing skeletal sites (spine, hip, femur neck, and calcaneus). Serum sclerostin levels were elevated above BL at BR-28 (+29% +/- 20%, p = 0.003), BR-60 (+42% +/- 31%, p < 0.001), and BR-90 (22% +/- 21%, p = 0.07). Serum PTH levels were reduced at BR-28 (-17% +/- 16%, p = 0.02), BR-60 (-24% +/- 14%, p = 0.03), and returned to baseline at BR-90 (-21% +/- 21%, p = 0.14). Serum bone turnover markers did not change, however urinary bone resorption markers and calcium were significantly elevated following bed rest (p < 0.01). CONCLUSION We observed an increase of serum sclerostin associated with decreased serum PTH and elevated bone resorption markers in otherwise healthy men subjected to long-term immobilization.

Spatz, J. M.↗

Engagement Assessment Using EEG Signals

In this paper, we present methods to analyze and improve an EEG-based engagement assessment approach, consisting of data preprocessing, feature extraction and engagement state classification. During data preprocessing, spikes, baseline drift and saturation caused by recording devices in EEG signals are identified and eliminated, and a wavelet based method is utilized to remove ocular and muscular artifacts in the EEG recordings. In feature extraction, power spectrum densities with 1 Hz bin are calculated as features, and these features are analyzed using the Fisher score and the one way ANOVA method. In the classification step, a committee classifier is trained based on the extracted features to assess engagement status. Finally, experiment results showed that there exist significant differences in the extracted features among different subjects, and we have implemented a feature normalization procedure to mitigate the differences and significantly improved the engagement assessment performance.

Li, Feng↗

Comparison of Knee and Ankle Dynamometry between NASA's X1 Exoskeleton and Biodex System 4

Pre- and post-flight dynamometry is performed on International Space Station crewmembers to characterize microgravity-induced strength changes. Strength is not assessed in flight due to hardware limitations and there is poor understanding of the time course of in-flight changes. PURPOSE: To assess the reliability of a prototype dynamometer, the X1 Exoskeleton (EXO) and its agreement with a Biodex System 4 (BIO). METHODS: Eight subjects (4 M/4 F) completed 2 counterbalanced testing sessions of knee extension/flexion (KE/KF), 1 with BIO and 1 with EXO, with repeated measures within each session in normal gravity. Test-retest reliability (test 1 and 2) and device agreement (BIO vs. EXO) were evaluated. Later, to assess device agreement for ankle plantarflexion (PF), 10 subjects (4 M/6 F) completed 3 test conditions (BIO, EXO, and BIOEXO); BIOEXO was a hybrid condition comprised of the Biodex dynamometer motor and the X1 footplate and ankle frame. Ankle comparisons were: BIO vs. BIOEXO (footplate differences), BIOEXO vs. EXO (motor differences), and BIO vs. EXO (all differences). Reliability for KE/KF was determined by intraclass correlation (ICC). Device agreement was assessed with: 1) repeated measures ANOVA, 2) a measure of concordance (rho), and 3) average difference. RESULTS: ICCs for KE/KF were 0.99 for BIO and 0.96 to 0.99 for EXO. Agreement was high for KE (concordance: 0.86 to 0.95; average differences: -7 to +9 Nm) and low to moderate for KF (concordance: 0.64 to 0.78; average differences: -4 to -29 Nm, P<0.05). BIO vs. BIOEXO PF concordance ranged from 0.89 to 0.92 and mean differences ranged from -9 to +3 Nm (BIO < BIOEXO). BIOEXO vs. EXO PF concordance ranged from 0.73 to 0.80 while mean differences were -18 to -36 Nm (BIOEXO < EXO, P<0.05). PF concordance for BIO vs. EXO was slightly lower (0.61 to 0.84) and mean differences were greater (-27 to -33 Nm; BIO < EXO, P<0.05). CONCLUSION: BIO and EXO were similarly reliable for KE and KF. KE measures produced high agreement between devices; KF did not. For ankle PF, torque differences due to the two footplates were small. However, the X1 motor reports greater torques than the Biodex motor during PF. This first prototype provides proof of concept for a reliable, robotic-based exoskeleton to perform portable dynamometry for large muscle groups of the lower body.

English, K. L.↗

Temporal Changes in Left Ventricular Mechanics: Impact of Bed Rest and Exercise

The use of more sensitive and specific echocardiographic techniques such as speckle tracking imaging may address the current limitations of conventional cardiac imaging techniques to provide insight into the extent and time course of cardiac deconditioning following spaceflight or headdown tilt bed rest (HDTBR). METHODS Speckle tracking assessment of longitudinal, radial, and circumferential strain and twist was used to evaluate the impact of 70 days of HDTBR (n=7) and HDTBR + exercise (n=11) on temporal changes in LV mechanics. Echocardiograms were performed pre (BR‐2), during (BR31, 70), and following (BR+4hr) HDTBR. Repeated measures ANOVA was used to evaluate the effect of HDTBR on cardiac variables in control and exercise subjects. RESULTS After sedentary HDTBR, longitudinal (‐19.0 +/- 1.8% vs. ‐14.9 +/- 2.4%) and radial (15.0 +/- 1.9% vs. 11.3 +/- 2.2%) strain and twist (18.0 +/- 4.0deg vs. 17.0 +/- 3.6deg) were significantly impaired. In contrast, exercise preserved LV mechanics, and there were non‐significant improvements from BR‐2 to BR70 in longitudinal strain (‐18.7 +/- 1.5% vs. ‐20.4 +/- 2.7%), radial strain (13.2 +/- 2.4% vs. 14.2 +/- 1.6%), and twist (16.3 +/- 3.6deg vs. 18.6 +/- 5.9deg). CONCLUSIONS Using speckle tracking echocardiography provides important new insights into temporal changes in LV mechanics during disuse and exercise training.

Scott, J. M.↗

Focal Gray Matter Plasticity as a Function of Long Duration Head Down Tilted Bed Rest: Preliminary Results

Long duration spaceflight (i.e., 22 days or longer) has been associated with changes in sensorimotor systems, resulting in difficulties that astronauts experience with posture control, locomotion, and manual control. The microgravity environment is an important causal factor for spaceflight induced sensorimotor changes. Whether these sensorimotor changes are solely related to peripheral changes from reduced vestibular stimulation, body unloading, body fluid shifts or that they may be related to structural and functional brain changes is yet unknown. However, a recent study reported associations between microgravity and flattening of the posterior eye globe and protrusion of the optic nerve [1] possibly as the result of increased intracranial pressure due to microgravity induced bodily fluid shifts [3]. Moreover, elevated intracranial pressure has been related to white matter microstructural damage [2]. Thus, it is possible that spaceflight may affect brain structure and thereby cognitive functioning. Long duration head down tilt bed rest has been suggested as an exclusionary analog to study microgravity effects on the sensorimotor system [4]. Bed rest mimics microgravity in body unloading and bodily fluid shifts. In consideration of the health and performance of crewmembers both in- and post-flight, we are conducting a prospective longitudinal 70-day bed rest study as an analog to investigate the effects of microgravity on brain structure [5]. Here we present results of the first six subjects. Six subjects were assessed at 12 and 7 days before-, at 7, 30, and ~70 days in-, and at 8 and 12 days post 70 days of bed rest at the NASA bed rest facility in UTMB, Galveston, TX, USA. At each time point structural MRI scans (i.e., high resolution T1-weighted imaging and Diffusion Tensor Imaging (DTI)) were obtained using a 3T Siemens scanner. Focal changes over time in gray matter density were assessed using the voxel based morphometry 8 (VBM8) toolbox under SPM. Longitudinal processing in VBM8 includes linear registration of each scan to the mean of the subject and subsequently transforming all scans in to MNI space by applying the warp from the mean subject to MNI to the individual gray matter segmentations. Modulation was applied so that all images represented the volume of the original structure in native space. Voxel wise analysis was carried out on the gray matter images after smoothing, using a flexible factorial design with family wise error correction. Focal changes in white matter microstructural integrity were assessed using tract based spatial statistics (TBSS) as part of FMRIB software library (FSL). TBSS registers all DTI scans to standard space. It subsequently creates a study specific white matter skeleton of the major white matter tracts. For each subject, for each DTI metric (i.e. fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD)), the maximum value in a line perpendicular to the skeleton tract is projected to the skeleton. Non-parametric permutation based t-tests and ANOVA's were used for voxel-wise comparison of the skeletons. For both VBM and TBSS, comparison of pre bed rest measurements did not show significant differences. VBM analysis revealed decreased gray matter density in bilateral areas including the frontal medial cortex, the insular cortex and the caudate (see Figure) from 'pre to in bed rest'. Over the same time period, there was an increase in gray matter density in the cerebellum, occipital-, and parietal cortex, including the precuneus (see Figure). The majority of these changes did not recover from 'during to post bed rest'. TBSS analysis did not reveal significant changes in white matter microstructural integrity after correction for multiple comparisons. Uncorrected analyses (p<.015) revealed an increase in RD in the cerebellum and brainstem from pre bed rest to the first week in bed rest that did not recover post bed rest. Extended bed rest, which is an analog for microgravity, can result in gray matter changes and potentially in microstructural white matter changes in areas that are important for neuro motor behavior and cognition. These changes did not recover at two weeks post bed rest. Whether the effects of bed rest wear off at longer times post bed rest, and if they are associated with behavior are important questions that warrant further research.

Koppelmans, V.↗

Validity and Reliability of Dynamic Visual Acuity (DVA) Measurement During Walking

DVA is primarily subserved by the vestibulo‐ocular reflex mechanism. Individuals with vestibular hypofunction commonly experience highly debilitating illusory movement or blurring of visual images during daily activities possibly, due to impaired DVA. Even without pathologies, gradual age‐related morphological deterioration is evident in all components of the vestibular system. We examined the construct validity to detect age‐related differences and test‐retest reliability of DVA measurements performed during walking. METHODS: Healthy adults were recruited into 3 groups: 1. young (20‐39years, n=18), 2. middle‐aged (40‐59years, n=14), and 3. older adults (60‐80years, n=15). Randomly selected seven participants from each group (n=21) participated in retesting. Participants were excluded if they had a history of vestibular or neuromuscular pathologies, dizziness/vertigo or >1 falls in the past year. Older persons with MMSE scores <29/30 were excluded to minimize cognitive errors. Participants' age, height, weight and normal walking speed were recorded. The binocular DVA was measured while walking on a treadmill at 0.8 m/s, 1.0 m/s and 1.2 m/s speeds. The walking speeds chosen represent a range of slow to moderate walking speeds for adult life span in participants who have no current mobility problems. The monitor that displayed Landolt 'C' optotypes was placed at 50 cm from the eyes for nearDVA (primary compensation by otolith organs) and at 3.0 m for farDVA (primary compensation by semicircular canals). A mixed factor ANOVA (age group x speed) was performed separately for the Near and FarDVA for detecting group differences. Intraclass correlation coefficients (ICCs) were calculated for each condition to determine test‐retest reliability. RESULTS: The three age groups were not different in their height, weight and normal walking speed (p>0.05). The post hoc analyses for DVA measurements demonstrated that each group was significantly different from the other two groups for Near as well as FarDVA (p<0.001‐p=0.031). The effect of speed was significant for both NearDVA (p=0.012) and FarDVA (p=0.014), however, there was no age group x speed interaction (FarDVA p=0.607, NearDVA p=0.343). The ICCs for Near and FarDVA ranged between 0.85‐ 0.88 and 0.71‐0.87, respectively. CONCLUSIONS: Differences in DVA between the three age groups were detected by using both Near and FarDVA protocols irrespective of the walking speed. Therefore, age group‐specific reference values should be used for detecting malfunction. Further, consistency in walking speed is critical for comparing between studies. NearDVA at all walking speeds and FarDVA at the speed of 1.2 m/s demonstrated excellent testretest reliability. FarDVA at 0.8 m/s and 1.0 m/s demonstrated good test‐retest reliability (ICCs 0.71 and 0.77, respectively).

Deshpande, Nandini↗

Focal Gray Matter Plasticity as a Function of Long Duration Bedrest: Preliminary Results

Long duration spaceflight (i.e., 22 days or longer) has been associated with changes in sensorimotor systems, resulting in difficulties that astronauts experience with posture control, locomotion, and manual control. It is unknown whether and how spaceflight impacts sensorimotor brain structure and function, and whether such changes may potentially underlie behavioral effects. Long duration head down tilt bed rest has been used repeatedly as an exclusionary analog to study microgravity effects on the sensorimotor system [1]. Bed rest mimics microgravity in body unloading and bodily fluid shifts. We are currently testing sensorimotor function, brain structure, and brain function pre and post a 70‐day bed rest period. We will acquire the same measures on NASA crewmembers starting in 2014. Here we present the results of the first eight bed rest subjects. Subjects were assessed at 12 and 7 days before‐, at 7, 30, and ~70 days in‐, and at 8 and 12 days post 70 days of bed rest at the NASA bed rest facility, UTMB, Galveston, TX, USA. At each time point structural MRI scans (i.e., high resolution T1‐weighted imaging and Diffusion Tensor Imaging (DTI)) were obtained using a 3T Siemens scanner. Focal changes over time in gray matter density were assessed using the voxel based morphometry 8 (VBM8) toolbox under SPM. Focal changes in white matter microstructural integrity were assessed using tract based spatial statistics (TBSS) as part of the FMRIB software library (FSL). TBSS registers all DTI scans to standard space. It subsequently creates a study specific white matter skeleton of the major white matter tracts. Non‐parametric permutation based t‐tests and ANOVA's were used for voxel‐wise comparison of the skeletons. For both VBM and TBSS, comparison of the two pre bed rest measurements did not show significant differences. VBM analysis revealed decreased gray matter density in bilateral areas including the frontal medial cortex, the insular cortex and the caudate nucleus from pre to in bed rest. Over the same time period, there was an increase in gray matter density in the cerebellum, occipital, and parietal cortices. The majority of these changes did not recover from during to post bed rest. TBSS analyses will also be presented. Extended bed rest, which is an analog for microgravity, can result in gray matter changes and potentially in microstructural white matter changes in areas that are important for neuromotor behavior and cognition. These changes did not recover at two weeks post bed rest. These results have significant public health implications, and will also aid in interpretation of our future data obtained pre and post spaceflight. Whether the effects of bed rest wear off at longer times post bed rest, and if they are associated with behavior are important questions that warrant further research.

Koppelmans, V.↗

Columnar Aerosol Properties from Sun-and-star Photometry: Statistical Comparisons and Day-to-night Dynamic

This work presents the first analysis of longterm correlative day-to-night columnar aerosol optical properties. The aim is to better understand columnar aerosol dynamic from ground-based observations, which are poorly studied until now. To this end we have used a combination of sun-and-star photometry measurements acquired in the city of Granada (37.16 N, 3.60 W, 680 ma.s.l.; South-East of Spain) from 2007 to 2010. For the whole study period, mean aerosol optical depth (AOD) around 440 nm (+/-standard deviation) is 0.18 +/- 0.10 and 0.19 +/- 0.11 for daytime and nighttime, respectively, while the mean Angstr¨om exponent (alpha ) is 1.0 +/- 0.4 and 0.9 +/- 0.4 for daytime and nighttime. The ANOVA statistical tests reveal that there are no significant differences between AOD and obtained at daytime and those at nighttime. Additionally, the mean daytime values of AOD and obtained during this study period are coherent with the values obtained in the surrounding AERONET stations. On the other hand, AOD around 440 nm present evident seasonal patterns characterised by large values in summer (mean value of 0.20 +/- 0.10 both at daytime and nighttime) and low values in winter (mean value of 0.15 +/- 0.09 at daytime and 0.17 +/- 0.10 at nighttime). The Angstr¨om exponents also present seasonal patterns, but with low values in summer (mean values of 0.8 +/- 0.4 and 0.9 +/- 0.4 at dayand night-time) and relatively large values in winter (mean values of 1.2 +/- 0.4 and 1.0 +/- 0.3 at daytime and nighttime). These seasonal patterns are explained by the differences in the meteorological conditions and by the differences in the strength of the aerosol sources. To take more insight about the changes in aerosol particles between day and night, the spectral differences of the Angstrom exponent as function of the Angstr¨om exponent are also studied. These analyses reveal increases of the fine mode radius and of the fine mode contribution to AOD during nighttime, being more remarkable in the summer seasons. These variations are explained by the changes of the local aerosol sources and by the meteorological conditions between daytime and nighttime, as well as aerosol aging processes. Case studies during summer and winter for different aerosol loads and types are also presented to clearly illustrate these findings.

columnar aerosol optical properties↗

Effects of Reduced Strength on Self-Selected Pacing for Long-Duration Activities

Strength and aerobic capacity are predictors of astronaut performance for extravehicular activities (EVA) during exploration missions. It is expected that astronauts will self‐select a pace below their ventilatory threshold (VT). PURPOSE: To determine the percentage of VT that subjects self‐select for prolonged occupational tasks. METHODS: Maximal aerobic capacity and a variety of lower‐body strength and power variables were assessed in 17 subjects who climbed 480 rungs on a ladder ergometer and then completed 10 km on a treadmill as quickly as possible using a self‐selected pace. The tasks were performed on 4 days, with a weighted suit providing 0% (suit fabric only), 40%, 60%, and 80% of additional bodyweight (BW), thereby altering the strength to BW ratio. Oxygen consumption and heart rate were continuously measured. Repeated measures ANOVA and post‐hoc comparisons were performed on the percent of VT values under each suited condition. RESULTS: Subjects consistently self‐paced at or below VT for both tasks and the pace was related to suit weight. At the midpoint for the ladder climb the 80% BW condition elicited the lowest metabolic cost (‐19+/-14% below VT), significantly different than the 0% BW (‐3+/-16%, P=0.002) and the 40% BW conditions (‐5+/-22%, P=0.023). The 60% BW condition (‐13+/-19%) was different than the 40% BW condition (P=0.034). Upon completion of the ladder task there were no differences among the conditions (0%BW: 3+/-18%; 40%BW: 3+/-21%; 60%BW: ‐ 8+/-25%; 80%BW: ‐10+/-18%). All subjects failed to complete 5km at 80%BW. At the midpoint of the treadmill test the three remaining conditions were all significantly different (0%BW: ‐20+/-15%; 40%BW: ‐ 33+/-15%; 60%BW: ‐41+/-19%). Upon completion of the treadmill test the 60% BW condition (‐38+/-12%) was significantly different than the 40% BW (‐28+/-15%, P=0.024). CONCLUSIONS: Decreasing relative strength results in progressive and disproportionate decreases (relative to VT) in self‐selected pacing during long‐duration activities. Thus, during prolonged, endurance‐type activities, large reductions in strength cause notable performance decrements despite no changes in aerobic capacity. These data highlight the importance of both aerobic capacity and muscle strength to the performance of prolonged EVA in exploration mission scenarios.

Buxton, Roxanne E.↗

Characterization of Machine Variability and Progressive Heat Treatment in Selective Laser Melting of Inconel 718

The absence of an economy of scale in spaceflight hardware makes additive manufacturing an immensely attractive option for propulsion components. As additive manufacturing techniques are increasingly adopted by government and industry to produce propulsion hardware in human-rated systems, significant development efforts are needed to establish these methods as reliable alternatives to conventional subtractive manufacturing. One of the critical challenges facing powder bed fusion techniques in this application is variability between machines used to perform builds. Even with implementation of robust process controls, it is possible for two machines operating at identical parameters with equivalent base materials to produce specimens with slightly different material properties. The machine variability study presented here evaluates 60 specimens of identical geometry built using the same parameters. 30 samples were produced on machine 1 (M1) and the other 30 samples were built on machine 2 (M2). Each of the 30-sample sets were further subdivided into three subsets (with 10 specimens in each subset) to assess the effect of progressive heat treatment on machine variability. The three categories for post-processing were: stress relief, stress relief followed by hot isostatic press (HIP), and stress relief followed by HIP followed by heat treatment per AMS 5664. Each specimen (a round, smooth tensile) was mechanically tested per ASTM E8. Two formal statistical techniques, hypothesis testing for equivalency of means and one-way analysis of variance (ANOVA), were applied to characterize the impact of machine variability and heat treatment on six material properties: tensile stress, yield stress, modulus of elasticity, fracture elongation, and reduction of area. This work represents the type of development effort that is critical as NASA, academia, and the industrial base work collaboratively to establish a path to certification for additively manufactured parts. For future flight programs, NASA and its commercial partners will procure parts from vendors who will use a diverse range of machines to produce parts and, as such, it is essential that the AM community develop a sound understanding of the degree to which machine variability impacts material properties.

Prater, T.↗

Characterization of Machine Variability and Progressive Heat Treatment in Selective Laser Melting of Inconel 718

The absence of an economy of scale in spaceflight hardware makes additive manufacturing an immensely attractive option for propulsion components. As additive manufacturing techniques are increasingly adopted by government and industry to produce propulsion hardware in human‐rated systems, significant development efforts are needed to establish these methods as reliable alternatives to conventional subtractive manufacturing. One of the critical challenges facing powder bed fusion techniques in this application is variability between machines used to perform builds. Even with implementation of robust process controls, it is possible for two machines operating at identical parameters with equivalent base materials to produce specimens with slightly different material properties. The machine variability study presented here evaluates 60 specimens of identical geometry built using the same parameters. 30 samples were produced on machine 1 (M1) and the other 30 samples were built on machine 2 (M2). Each of the 30‐sample sets were further subdivided into three subsets (with 10 specimens in each subset) to assess the effect of progressive heat treatment on machine variability. The three categories for post‐processing were: stress relief, stress relief followed by hot isostatic press (HIP), and stress relief followed by HIP followed by heat treatment per AMS 5664. Each specimen (a round, smooth tensile) was mechanically tested per ASTM E8. Two formal statistical techniques, hypothesis testing for equivalency of means and one‐way analysis of variance (ANOVA), were applied to characterize the impact of machine variability and heat treatment on six material properties: tensile stress, yield stress, modulus of elasticity, fracture elongation, and reduction of area. This work represents the type of development effort that is critical as NASA, academia, and the industrial base work collaboratively to establish a path to certification for additively manufactured parts. For future flight programs, NASA and its commercial partners will procure parts from vendors who will use a diverse range of machines to produce parts and, as such, it is essential that the AM community develop a sound understanding of the degree to which machine variability impacts material properties.

Prater, Tracie↗

Individual Variability in Aerobic Fitness Adaptations to 70-d of Bed Rest and Exercise Training

Change in maximal aerobic capacity (VO2pk) in response to exercise training and disuse is highly variable among individuals. Factors that could contribute to the observed variability (lean mass, daily activity, diet, sleep, stress) are not routinely controlled in studies. The NASA bed rest (BR) studies use a highly controlled hospital based model as an analog of spaceflight. In this study, diet, hydration, physical activity and light/dark cycles were precisely controlled and provided the opportunity to investigate individual variability. PURPOSE. Evaluate the contribution of exercise intensity and lean mass on change in VO2pk during 70-d of BR or BR + exercise. METHODS. Subjects completed 70-d of BR alone (CON, N=9) or BR + exercise (EX, N=17). The exercise prescription included 6 d/wk of aerobic exercise at 70 - 100% of max and 3 d/wk of lower body resistance exercise. Subjects were monitored 24 hr/d. VO2pk and lean mass (iDXA) were measured pre and post BR. ANOVA was used to evaluate changes in VO2pk pre to post BR. Subjects were retrospectively divided into high and low responders based on change in VO2pk (CON > 20% loss, n=5; EX >10% loss, n=4, or 5% gain, n=4) to further understand individual variability. RESULTS. VO2pk decreased from pre to post BR in CON (P<0.05) and was maintained in EX; however, significant individual variability was observed (CON: -22%, range: -39% to -.5%; EX: -1.8%, range: -16% to 12.6%). The overlap in ranges between groups included 3 CON who experienced smaller reduction in VO2pk (<16%) than the worst responding EX subjects. Individual variability was maintained when VO2pk was normalized to lean mass (range, CON: -33.7% to -5.7%; EX: -15.8% to 11%), and the overlap included 5 CON with smaller reductions in VO2pk than the worst responding EX subjects. High responders to disuse also lost the most lean mass; however, this relationship was not maintained in EX (i.e. the largest gains/losses in lean mass were observed in both high and low responders). Change in VO2pk was not related to exercise intensity. CONCLUSION. Change in VO2pk in response to disuse and exercise was highly variable among individuals, even in this tightly controlled study. Loss in lean mass accounts for a significant degree of variability in the CON; however, training induced gains in VO2pk appear unrelated to lean mass or exercise intensity.

Downs, Meghan↗

Transgenic Mouse Model for Reducing Oxidative Damage in Bone

Exposure to musculoskeletal disuse and radiation result in bone loss; we hypothesized that these catabolic treatments cause excess reactive oxygen species (ROS), and thereby alter the tight balance between bone resorption by osteoclasts and bone formation by osteoblasts, culminating in bone loss. To test this, we used transgenic mice which over-express the human gene for catalase, targeted to mitochondria (MCAT). Catalase is an anti-oxidant that converts the ROS hydrogen peroxide into water and oxygen. MCAT mice were shown previously to display reduced mitochondrial oxidative stress and radiosensitivity of the CNS compared to wild type controls (WT). As expected, MCAT mice expressed the transgene in skeletal tissue, and in marrow-derived osteoblasts and osteoclast precursors cultured ex vivo, and also showed greater catalase activity compared to wildtype (WT) mice (3-6 fold). Colony expansion in marrow cells cultured under osteoblastogenic conditions was 2-fold greater in the MCAT mice compared to WT mice, while the extent of mineralization was unaffected. MCAT mice had slightly longer tibiae than WT mice (2%, P less than 0.01), although cortical bone area was slightly lower in MCAT mice than WT mice (10%, p=0.09). To challenge the skeletal system, mice were treated by exposure to combined disuse (2 wk Hindlimb Unloading) and total body irradiation Cs(137) (2 Gy, 0.8 Gy/min), then bone parameters were analyzed by 2-factor ANOVA to detect possible interaction effects. Treatment caused a 2-fold increase (p=0.015) in malondialdehyde levels of bone tissue (ELISA) in WT mice, but had no effect in MCAT mice. These findings indicate that the transgene conferred protection from oxidative damage caused by treatment. Unexpected differences between WT and MCAT mice emerged in skeletal responses to treatment.. In WT mice, treatment did not alter osteoblastogenesis, cortical bone area, moment of inertia, or bone perimeter, whereas in MCAT mice, treatment increased these parameters. Taken together, this typically catabolic treatment (disuse and irradiation) appeared to stimulate cortical expansion in MCAT mice but not WT mice. In conclusion, these results reveal the importance of mitochondrial ROS generation in skeletal remodeling and show that MCAT mice provide a useful animal model for bone studies.

trandgenic↗