Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absolute”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Phase curves of small bodies from the SLOAN Moving Objects Catalog

Extensive photometric surveys continue to produce enormous stores of data on small bodies. These data are typically sparsely obtained at arbitrary (or unknown) rotational phases. Therefore, new methods for processing such data need to be developed to make the most of these vast catalogs. We aim to produce a method of recreating the phase curves of small bodies by considering the uncertainties introduced by the nominal errors in the magnitudes and the effect introduced by rotational variations. Here, we use the SLOAN Moving Objects Catalog data as a benchmark to construct phase curves of all small bodies in u', g', r', i', and z' filters. From the phase curves, we obtain the absolute magnitudes and we use them to set up the absolute colors, which are the colors of the asteroids that are not affected by changes in the phase angle. We selected objects with ≥3 observations taken in at least one filter and spanning over a minimum of 5 degrees in the phase angle. We developed a method that combines Monte Carlo simulations and Bayesian inference to estimate the absolute magnitudes using the HG 12 * photometric system. We obtained almost 15 000 phase curves, with about 12 000 of these including all five filters. The absolute magnitudes and absolute colors are compatible with previously published data that support our method. The method we developed is fully automatic and well suited for a run based on large amounts of data. Moreover, it includes the nominal uncertainties in the magnitudes and the whole distribution of possible rotational states of the objects producing what are possibly less precise values, that is, larger uncertainties, but more accurate, namely, closer to the actual value. To our knowledge, this work is the first to include the effect of rotational variations in such a manner.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of an RF-driven argon plasma at atmospheric pressure using broadband absorption and optical emission spectroscopy

Atmospheric pressure plasmas in argon are of particular interest due to the production of highly excited and reactive species enabling numerous plasma-aided applications. In this contribution, we report on absolute optical emission and absorption spectroscopy of a radio frequency (RF) driven capacitively coupled argon glow discharge operated in a parallel-plate configuration. This enabled the study of all key parameters including electron density and temperature, gas temperature, and absolute densities of atoms in highly electronically excited states. The space and time-averaged electron density and temperature were determined from the measurement of the absolute intensity of the electron-atom bremsstrahlung in the visible range. Considering the non-Maxwellian electron energy distribution function, an electron temperature (T e ) of 2.1 eV and an electron density (n e ) of 1.1 × 10 19 m –3 were obtained. The time-averaged and spatially resolved absolute densities of atoms in the metastable (1s 5 and 1s 3 ) and resonant (1s 4 and 1s 2 ) states of argon in pure Ar and Ar/He mixture were obtained by broadband absorption spectroscopy. The 1s 5 metastable atoms had the largest density near the sheath region with a maximum value of 8 × 10 17 m –3 , while all other 1s states had densities of at most 2 × 10 17 m –3 . Here, the dominant production and loss mechanisms of these atoms were discussed, in particular, the role of radiation trapping. We conclude with a comparison of the plasma properties of the argon RF glow discharges with the more common He equivalent and highlight their differences.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Huzinaga projection embedding for efficient and accurate energies of systems with localized spin-densities

We demonstrate the accuracy and efficiency of the restricted open-shell and unrestricted formulation of the absolutely localized Huzinaga projection operator embedding method. Restricted open-shell and unrestricted Huzinaga projection embedding in the full system basis is formally exact to restricted open-shell and unrestricted Kohn–Sham density functional theory, respectively. By utilizing the absolutely localized basis, we significantly improve the efficiency of the method while maintaining high accuracy. Furthermore, the absolutely localized basis allows for high accuracy open-shell wave function methods to be embedded into a closed-shell density functional theory environment. The open-shell embedding method is shown to calculate electronic energies of a variety of systems to within 1 kcal/mol accuracy of the full system wave function result. For certain highly localized reactions, such as spin transition energies on transition metals, we find that very few atoms are necessary to include in the wave function region in order to achieve the desired accuracy. This extension further broadens the applicability of our absolutely localized Huzinaga level-shift projection operator method to include open-shell species. Here, we apply our method to several representative examples, such as spin splitting energies, catalysis on transition metals, and radical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scattered-light uniformity imager for diagnosing laser absorption asymmetries on OMEGA

Light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. Observations from OMEGA implosions show much larger scattered-light asymmetries than predictions. A new instrument has been developed to absolutely measure the scattered-light intensity and nonuniformity for the purpose of diagnosing the asymmetry. The scattered-light uniformity imager (SLUI) diagnostic records the variation in scattered-light intensity over a transmission diffuser using a charge-coupled device (CCD)/lens assembly. At the standard operating position, an 11.3° (f/2.5) cone of light is collected. A stray light baffle, debris shield, and antireflection absorbing filter are also incorporated into the diagnostic payload inserted into the target chamber. The imaging parts of the diagnostic (light baffle, vacuum window, filters, lens, and CCD camera) are located outside the target chamber. Five SLUIs have been built and deployed in OMEGA’s ten-inch manipulator diagnostic ports, covering almost 5% of the emission surface, enabling an absolute scattered-light measurement should be within a few percent of the global average. Each SLUI system is calibrated offline, providing absolute scattered-light intensity measurements. Based on the measured point spread function, each diffuser plate image contains over 20 000 independent scattered-light absolute-intensity measurements of the variation over the collection cone. SLUI provides a platform to study scattered light and absorption asymmetries, and their possible sources.

47 OTHER INSTRUMENTATION↗

Measurements and kinetic modeling of O 2 vibrational kinetics in O 2 –Ar mixtures partially dissociated by a Ns pulse discharge

Vibrational kinetics of O 2 is studied during the O atom recombination in an O 2 –Ar mixture, partially dissociated by a burst of ns discharge pulses in a heated plasma flow reactor. The time-resolved temperature in the discharge afterglow is determined by Rayleigh scattering. Time-resolved O atom number density is measured by ps Two-Photon absorption Laser Induced Fluorescence, calibrated in xenon. Time-resolved vibrational level populations of molecular oxygen, O 2 (v= 8–20), are measured by ps Laser Induced Fluorescence (LIF), with the absolute calibration by NO LIF. Time-resolved ozone number density is monitored by broadband UV absorption. The results are compared with the predictions of a state-specific kinetic model. The experimental data indicate a rapid initial decay of O 2 (v) populations generated by electron impact in the discharge, due to the vibration-translation (V–T) relaxation by O atoms. This is followed by a slower population reduction, on the time scale much longer compared to that for V–T relaxation or vibration-vibration (V–V) exchange. Both O atoms and the O 2 (v) populations decay on the same time scale, indicating that chemical reactions initiated by the O atom recombination result in the generation of vibrationally excited O 2 molecules. These trends are reproduced by the kinetic model, which shows that the reaction of O atoms with ozone is the dominant pathway of O 2 (v) generation at the present conditions. The predicted relative O 2 (v) populations are close to the experimental results, but absolute number densities differ from the experimental data. This is likely due to uncertainties in the absolute calibration of LIF measurements and in the spectroscopic model used in the data reduction. The present work demonstrates the capability for the absolute, time-resolved measurements of vibrationally excited O 2 in recombining gas flows, to quantify the energy partition in the recombination reactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat metrics and thresholds reshape population exposure and inequality signals

Extreme heat is intensifying worldwide, yet estimates of heat hazard and exposure inequality depend on both the heat metric and how extreme days are defined. Using summer 2022 across the Mediterranean, we quantify population heat exposure with four metrics—land surface temperature (LST), air temperature (Ta), heat index (HI), and wet-bulb globe temperature (WBGT)—under absolute (fixed-value) and relative (anomaly-based) thresholds. Under absolute thresholds, total heat exposure differs by more than two orders of magnitude across metrics (31.3 billion person-days for Ta vs 0.3 billion for HI). Geographic hotspots also diverge: WBGT concentrates in humid coastal North Africa (e.g. the Nile Delta), whereas Ta and LST are more widespread. Under relative thresholds, exposure totals converge and cross-metric hotspot agreement increases (e.g. Ta–WBGT top-tercile overlap increases from 10.7% to 29.0%), shifting hotspots toward densely populated southern Europe. Crucially, the exposure–deprivation relationship also reverses across threshold frameworks: absolute thresholds concentrate exposure in more deprived North Africa and the Middle East, whereas relative thresholds shift the burden toward less-deprived European cities. This sensitivity is decision-relevant: city rankings based on WBGT exposure duration are almost completely reordered when switching threshold frameworks. Threshold choice therefore systematically reshapes hotspot patterns and inequality signals. Reporting both absolute and relative exposures can reveal hidden hotspots and support more targeted heat-risk monitoring and intervention planning.

Mediterranean↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Charging and ion ejection dynamics of large helium nanodroplets exposed to intense femtosecond soft xray pulses

Ion ejection from charged helium nanodroplets exposed to intense femtosecond soft X-ray pulses is studied by single-pulse ion time-of-flight (TOF) spectroscopy in coincidence with small-angle X-ray scattering. Scattering images encode the droplet size and absolute photon flux incident on each droplet, while ion TOF spectra are used to determine the maximum ion kinetic energy, Ekin, of He+ j fragments (j = 1-4). Measurements span HeN droplet sizes between N similar to 10(7) and similar to 10(10) (radii R-0 = 78-578 nm), and droplet charges between similar to 9x10(-5) and similar to 3x10(-3) e/atom. Conditions encompass a wide range of ionization and expansion regimes, from departure of all photoelectrons from the droplet, leading to pure Coulomb explosion, to substantial electron trapping by the electrostatic potential of the charged droplet, indicating the onset of hydrodynamic expansion. The unique combination of absolute Xray intensities, droplet sizes, and ion Ekin on an event-by-event basis reveals a detailed picture of the correlations between the ionization conditions and the ejection dynamics of the ionic fragments. The maximum E-kin of He+ is found to be governed by Coulomb repulsion from unscreened cations across all expansion regimes. The impact of ion-atom interactions resulting from the relatively low charge densities is increasingly relevant with less electron trapping. The findings are consistent with the emergence of a charged spherical shell around a quasineutral plasma core as the degree of ionization increases. The results demonstrate a complex relationship between measured ion E-kin and droplet ionization conditions that can only be disentangled through the use of coincident single-pulse TOF and scattering data.

Helium↗

Criterion validity of wrist accelerometry for assessing energy intake via the intake-balance technique

Background: Intake-balance assessments measure energy intake (EI) by summing energy expenditure (EE) with concurrent change in energy storage (ΔES). Prior work has not examined the validity of such calculations when EE is estimated via open-source techniques for research-grade accelerometry devices. The purpose of this study was to test the criterion validity of accelerometry-based intake-balance methods for a wrist-worn ActiGraph device. Methods: Healthy adults (n = 24) completed two 14-day measurement periods while wearing an ActiGraph accelerometer on the non-dominant wrist. During each period, criterion values of EI were determined based on ΔES measured by dual X-ray absorptiometry and EE measured by doubly labeled water. A total of 11 prediction methods were tested, 8 derived from the accelerometer and 3 from non-accelerometry methods (e.g., diet recall; included for comparison). Group-level validity was assessed through mean bias, while individual-level validity was assessed through mean absolute error, mean absolute percentage error, and Bland–Altman analysis. Results: Mean bias for the three best accelerometry-based methods ranged from -167 to 124 kcal/day, versus -104 to 134 kcal/day for the non-accelerometry-based methods. The same three accelerometry-based methods had mean absolute error of 323–362 kcal/day and mean absolute percentage error of 18.1-19.3%, versus 353–464 kcal/day and 19.5-24.4% for the non-accelerometry-based methods. All 11 methods demonstrated systematic bias in the Bland–Altman analysis. Conclusions: Accelerometry-based intake-balance methods have promise for advancing EI assessment, but ongoing refinement is necessary. We provide an R package to facilitate implementation and refinement of accelerometry-based methods in future research (see paulhibbing.com/IntakeBalance).

60 APPLIED LIFE SCIENCES↗

NREL Pyrheliometer Comparisons: September 23 - September 28, 2023 (NPC-2023)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, for improving our understanding of Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG. As with all measurement systems, Absolute Cavity Radiometers (ACR) are subject to performance changes over time. Therefore, PMOD/WRC in Davos, Switzerland, hosts an quinquennial International Pyrheliometer Comparison (IPC) event for transferring the WRR to participating radiometers by invitation. The National Renewable Energy Laboratory (NREL) has represented the U.S. Department of Energy (DOE) in each IPC since 1980. And NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the WRR, and it uses these reference instruments to calibrate pyrheliometers and pyranometers using the International Organization for Standardization (ISO) 17025-accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). To fill the gap between each IPC, NREL pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all ACR owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR.

14 SOLAR ENERGY↗

Impact of simulated reduced injected dose on the assessment of amyloid PET scans

To investigate the impact of reduced injected doses on the quantitative and qualitative assessment of the amyloid PET tracers [ 18 F]flutemetamol and [ 18 F]florbetaben. Cognitively impaired and unimpaired individuals (N = 250, 36% Aβ-positive) were included and injected with [ 18 F]flutemetamol (N = 175) or [ 18 F]florbetaben (N = 75). PET scans were acquired in list-mode (90–110 min post-injection) and reduced-dose images were simulated to generate images of 75, 50, 25, 12.5 and 5% of the original injected dose. Images were reconstructed using vendor-provided reconstruction tools and visually assessed for Aβ-pathology. SUVRs were calculated for a global cortical and three smaller regions using a cerebellar cortex reference tissue, and Centiloid was computed. Absolute and percentage differences in SUVR and CL were calculated between dose levels, and the ability to discriminate between Aβ- and Aβ + scans was evaluated using ROC analyses. Finally, intra-reader agreement between the reduced dose and 100% images was evaluated. At 5% injected dose, change in SUVR was 3.72% and 3.12%, with absolute change in Centiloid 3.35CL and 4.62CL, for [ 18 F]flutemetamol and [ 18 F]florbetaben, respectively. At 12.5% injected dose, percentage change in SUVR and absolute change in Centiloid were < 1.5%. AUCs for discriminating Aβ- from Aβ + scans were high (AUC ≥ 0.94) across dose levels, and visual assessment showed intra-reader agreement of > 80% for both tracers. This proof-of-concept study showed that for both [ 18 F]flutemetamol and [ 18 F]florbetaben, adequate quantitative and qualitative assessments can be obtained at 12.5% of the original injected dose. However, decisions to reduce the injected dose should be made considering the specific clinical or research circumstances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of Pile-Up Effects in Decay Energy Spectroscopy

Pile-up is an unavoidable complication for cryogenic detectors with relatively large heat capacities and slow rise time, such as systems for decay energy spectroscopy employing large Au absorbers. We have simulated the spectral response of such slow cryogenic detectors using Monte-Carlo algorithms to investigate the effects of pile-up on absolute and relative activity measurements. We focus on the impact of non-distinguishable pile-up that occurs when the rising edges of two waveforms originating from different events overlap in time and are interpreted as a single event. This effect can not be readily identified and corrected in experimental data. We investigated two representative cases of absolute decay counting and plutonium isotopic analysis and find that pile-up can distort the reconstruction of both the absolute and relative activities. This Monte-Carlo methodology quantifies of pile-up effects and provides a systematic methodology for calculating corrective factors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A miniature jet pump for slurries

Here, this work reports on the design and performance of a jet pump system to pump slurries. The jet pump uses a high-velocity water jet to entrain and pump the slurry. This pumping action requires no valves and does not use moving solid parts. Hence, the system can be readily sealed, and the pumping action creates no observable mechanical damage to slurry particles. We tested carbon black beads suspended in water at concentrations of 0.0, 0.2, and 2.0 wt% at primary jet flow rates of 50 and 100 mL/min. Our measurements show an approximately linear decrease in entrainment ratio (slurry-to-jet flow rate) and absolute slurry flow rate with increasing adverse (load) pressure difference. The entrainment ratio is a strong function of the absolute jet flow rate. Pump performance was insensitive to slurry composition. Micron-resolution particle image velocimetry (micro-PIV) revealed qualitative changes in the pump’s internal flow due to changes in absolute jet flow rate, including evidence of the suppression of a vortex at higher flow rates. These findings establish key operational parameters for the jet pump and highlight its potential in a variety of slurry flow pumping applications. The pump is particularly suited for flow electrode slurries (e.g. as used for energy storage and water treatment) as it maintains particle integrity and can be used with standard tubing, tube fittings, and sealing methods.

42 ENGINEERING↗

Time-resolved measurements of HO 2 radical in a heated plasma flow reactor

Time-resolved, absolute HO 2 number density in diluted H 2 –O 2 –Ar, CH 4 –O 2 -Ar, and C 2 H 4 –O 2 –Ar mixtures excited by a repetitive ns pulse discharge in a heated plasma flow reactor is measured by Cavity Ringdown Spectroscopy (CRDS). The experimental results are obtained at $\textit{T}$ = 300-600 K and $\textit{P}$ = 130 Torr, both during the discharge pulse burst and in the afterglow. In this work, the HO 2 number density is inferred from the CRDS data using a spectral model exhibiting good agreement with previous measurements of absolute HO 2 absorption cross sections. In the room-temperature H 2 –O 2 mixture, as well as in CH 4 –O 2 and C 2 H 4 –O 2 mixtures over the entire temperature range studied, HO2 is generated only during the discharge burst and decays in the afterglow. However, in the H 2 –O 2 mixture at elevated temperatures, $\textit{T}$ = 400-600 K, HO 2 persists in the afterglow up to 10 ms after the discharge burst, comparable with the flow residence time in the reactor. Comparison with kinetic modeling shows that the sustained reactivity after the source of radicals is turned off is due to a chain propagation / hydrogen oxidation process, which dominates the radical recombination reactions. The kinetic modeling predictions are in good agreement with the relative HO 2 number density measured in all three mixtures, although the model underpredicts the absolute number densities in H 2 –O 2 at $\textit{T}$ = 400-600 K by up to a factor of two. Detection of the sustained low-temperature reactivity in H 2 –O 2 , initiated by the radical generation in the plasma, suggests that the plasma excitation may also affect kinetics of oxidation and reforming of fuels exhibiting low-temperature chemistry below hot ignition point.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using non-invasive MEMS pressure sensors for measuring building envelope air leakage

Micro-electromechanical systems (MEMS)-based sensors have seen significant improvements in accuracy and cost over the past several years, and due to the need for altitude sensing in unmanned aerial vehicles and wearable technologies, absolute pressure sensors have shown the most dramatic improvements. This paper investigates applications of MEMS sensors in commercial buildings, including pairing two absolute pressure sensors to determine differential pressures between different locations in and around buildings. Differential pressure measurements are commonly made in commercial buildings for a number of applications, including static pressure measurements for variable-speed supply fan control, air balancing in hospitals, and for envelope and duct air leakage testing. This paper focuses specifically on envelope air-leakage testing applications of these sensors. The use of continuous pressure measurements in addition to one-time non-intrusive outdoor airflow measurements of rooftop packaged units is investigated. A comparison with standardized leakage testing indicated that continuous measurements with MEMS pressure-sensors were able to estimate envelope leakage to within 3–16% of the standardized test result. In addition, the magnitude and stability of differential pressure differences that can be resolved with absolute pressure sensors are also investigated in the laboratory and the field. Results show that the sensors can be effectively used for pressures seen in low rise buildings with rooftop units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reduced-Order Modeling Method for Phase-Change Thermal Energy Storage Heat Exchangers

Thermal energy storage can facilitate the effective utilization of renewable energy. To speed up the design process of thermal energy storage devices, it is critical to develop fast and accurate modeling methods for phase change material embedded heat exchangers (PCM HXs). This study developed and compared two approximation-assisted reduced-order PCM HX models for the simulation of thermal storage components and systems, which were verified against a validated finite-volume model. They are a pure black-box model, and a grey-box model based on the Number of Transfer Units (or effectiveness-NTU) approach. We used the reduced-order models to predict the performance of standalone PCM HX for 1000 cases with different fluid inlet conditions and HX designs. We also integrated the models with a vapor compression system to predict the compressor energy consumption and total charging time under various conditions. The results show that overall, the black-box model gave more accurate results than the grey-box model. On average, the mean absolute deviation in the PCM HX fluid outlet temperature was 0.05 K and 0.1 K for the black-box model and grey-box model, respectively. The grey-box model gave larger temperature deviation toward the end of the phase change process, due to the simplified two-node PCM representation. On the system level, the mean absolute deviation in compressor energy consumption was 0.2% and 0.3% for the black-box model and grey-box model, respectively. Their mean absolute deviation in total charging time was 1.1% and 2.6%, respectively. In terms of computation efficiency, the system simulation speedup ratio gained by using the reduced-order models was 11 to 57. System simulation time was decreased from an average of 1465 s to an average of 59 s. This shows that the proposed reduced-order modeling methods can be used to predict system performance of PCM HXs with less than 3% accuracy penalty, and 25 times less computational time than finite-volume models, enabling faster design and evaluation of PCM thermal storage devices.

25 ENERGY STORAGE↗

Monte Carlo calculations of the extraction of scintillation light from cryogenic $N$-type GaAs

We report the high scintillation luminosity of n-type GaAs at 10 °K is surprising because (1) with a refractive index of 3.5, escape is inhibited by total internal reflection and (2) narrow-beam experiments at 90 °K report infrared absorption coefficients of several per cm. This paper presents Monte Carlo calculations showing that the high luminosity at 10 °K can be explained if (1) the narrow-beam absorption is almost all optical scattering and (2) the absolute absorption coefficient is below 0.1 per cm. Sixteen surface reflector configurations are simulated for a range of internal scattering and absolute absorption coefficients, and these can guide the design of cryogenic scintillating GaAs targets for the direct detection of dark matter. The discussion section presents a possible infrared scattering mechanism based on the metallic nature of n-type GaAs. A supplement file describes (1) the Monte Carlo program steps in detail and (2) how narrow-beam and integrating sphere experiments can measure the cryogenic optical scattering and absolute absorption coefficients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robust, Accurate, and Efficient: Quantum Embedding Using the Huzinaga Level-Shift Projection Operator for Complex Systems

Using wave function (WF) in density functional theory (DFT) embedding methods provides a framework for performing localized, high-accuracy WF calculations on a system, while not incurring the full computational cost of the WF calculation on the full system. To effectively partition a system into localized WF and DFT subsystems, we utilize the Huzinaga level-shift projection operator within an absolutely localized basis. In this work, we study the ability of the absolutely localized Huzinaga level-shift projection operator method to study complex WF and DFT partitions, including partitions between multiple covalent bonds, a double bond, and transition-metal–ligand bonds. We find that our methodology can accurately describe all of these complex partitions. Additionally, we study the robustness of this method with respect to the WF method, specifically where the embedded systems were described using a multiconfigurational WF method. We found that the method is systematically improvable with respect to both the number of atoms in the WF region and the size of the basis set used, with energy errors less than 1 kcal/mol. Additionally, we calculated the adsorption energy of H2 to a model of an iron metal–organic framework (Fe-MOF-74) to within 1 kcal/mol compared to CASPT2 calculations performed on the full model while incurring only a small fraction of the full computational cost. In conclusion, this work demonstrates that the absolutely localized Huzinaga level-shift projection operator method is applicable to very complex systems with difficult electronic structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗