Structural and electrochemical investigation of crystallite size controlled zinc ferrite (ZnFe2O4)
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Sodium superionic conductor (NASICON)-type materials are widely explored as Li- and Na-ion cathodes and solid-state electrolytes but are largely ignored as anodes due to their lower capacities and higher intercalation voltages, which reduce the overall energy densities of Li- and Na-ion batteries (LIBs and SIBs). Herein, we unveil high capacity multi-redox empty NASICON-Nb 2 (PO 4 ) 3 as a potential anode material for LIBs and SIBs, which reversibly delivers 167 and 150 mA h g -1 at the average voltages of 1.86 V vs. Li + /Li 0 and 1.46 V vs. Na + /Na 0 , respectively. The Li and Na intercalation reactions proceed via multiple phase transitions, leading to short-range ordered Li 3 Nb 2 (PO 4 ) 3 and triclinic (P$\overline{1}$ with combining macron]) Na 3 Nb 2 (PO 4 ) 3 , as revealed by in situ X-ray diffraction studies. Our density functional theory calculations are also in agreement with the in situ measurements in predicting a stable Na 3 Nb 2 (PO 4 ) 3 composition in the Na–Nb 2 (PO 4 ) 3 pseudo-binary system. X-ray absorption spectroscopy confirms the participation of multi-redox Nb 5+ /Nb 4+ /Nb 3+ couples. The Nb 2 (PO 4 ) 3 anode delivers capacities greater than 124 and 106 mA h g -1 at 1C rate in Li and Na cells, respectively. In conclusion, pairing Nb 2 (PO 4 ) 3 with suitable cathodes and electrolytes can lead to high energy density batteries.
The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.
Owing to the negative impact of the extensive utilization of batteries on the environment, sustainability of the cells needs to be included in the systemic research of batteries. In this work, a dissolvable ionic crosslinked polymer (DICP) is exploited as a binder for lithium–sulfur batteries by crosslinking the polyacrylic acid and polyethyleneimine through carboxy-amino ionic interaction. This interaction is pH-controlled, and therefore, the crosslinked binder network can be readily dissociated under basic conditions, providing a facile strategy enabling valuable components recycled through a convenient washing method. The sulfur cathode prepared using the recycled carbon–sulfur composite can deliver comparable capacity as that of fresh electrode. In addition, evidence from cell performance and characterizations, such as in situ X-ray absorption spectroscopy, in situ UV–visible spectroscopy, X-ray photoelectron spectroscopy, and density functional theory calculation, confirms that DICP is a more effective binder than its commercial counterpart on suppressing polysulfide dissolution in the electrolyte. Exploiting reversible crosslinked polymer binder for recyclable Li–S batteries with ameliorated electrochemical performance, this study illuminates sustainable development for large-scale energy storage systems.
Concrete is a key building material around the world due to its excellent strength and durability. Recycling demolished concrete for new construction materials may play a significant role in sustainable development. Producing recycled concrete aggregates (RCA) from waste concrete is one approach for such an initiative. However, using RCA may pose challenges, such as reduced density, lower elastic modulus and strength, and increased water absorption. Recently, the carbonation of RCA has emerged as a method to address those concerns. This study explores the carbon sequestration capacity of RCA through carbonation, examining various parametric conditions, including initial CO 2 pressure, relative humidity, temperature, and pre-treatment approach. Both lab-scale and large-scale carbonation tests were conducted. Additionally, a cost analysis and CO 2 footprint assessment were performed. The findings showed that applying higher initial CO 2 pressures (e.g., 40–60 psi) and optimal relative humidity (~55 %) could significantly enhance the carbonation efficiency of RCA. Elevating temperature also led to accelerated CO 2 consumption, being more effective on the lab scale. The economic analysis presented potential cost benefits when substituting natural aggregates with CO 2 -treated RCA. All in all, these results suggest that the carbonation of RCA may provide significant environmental benefits through carbon sequestration, promoting sustainable construction practices.
Improving the fast charging performance of lithium ion batteries (LIBs) has the promise to increase the widespread adoption of electric vehicles (EVs). Electrolyte development plays an important role in enabling fast charging. In this study, fast charging performance of LIBs is studied with different electrolytes of 1.2 M LiPF 6 in Ethylene Carbonate (EC)/Ethyl Methyl Carbonate (EMC)/co-solvents at 30/50/20 wt%. The co-solvents are methyl acetate (MA), ethyl acetate (EA), ethyl formate (EF), dimethyl carbonate (DMC) and EMC. Long term cycling performance under fast charging shows different capacity retention behaviors for different co-solvents. The structural changes in the electrode material are studied by X-ray absorption spectroscopy (XAS) and X-ray diffraction (XRD). The molarity changes in electrolyte is investigated by inductively coupled plasma-optical emission spectroscopy (ICP-OES). The electrode/electrolyte interfaces before and after fast charging are analyzed by X-ray photoemission spectroscopy (XPS). The characterization results are in good agreement with the long-term cycling performance. DMC shows the highest fast-charging capability among the five studied co-solvents due to its increased conductivity, improved electrode/electrolyte interface and stable electrode structural integrity.
Abstract not provided
Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity
The current spent nuclear fuel (SNF) management strategy includes reliance on dry storage. Utilities are meeting their interim storage needs on an individual basis with use of large-capacity dry storage casks, with a current focus on meeting existing storage and transportation requirements, as disposal requirements are not currently available. These casks are commonly known as dual-purpose (i.e., storage and transportation) canisters (DPCs). However, a small percentage of single-purpose (storage only) systems is also being used to meet storage needs. These are included under the “DPC” heading. This report investigates the postclosure criticality safety aspects of DPCs. Placing large, heavy waste packages containing DPCs into a repository for direct disposal has not yet been implemented domestically or internationally. Therefore, direct disposal of DPCs represents new engineering and scientific challenges. Some of the engineering challenges that have already been addressed include handling and placement, use of ramps vs. shafts, use of hoists, use of transport equipment, and thermal management. Additionally, some studies have been conducted in the past regarding the feasibility of direct disposal from a criticality analysis perspective and have concluded that while possible, demonstrating subcriticality over the disposal time period is a challenge. The alternative to direct disposal of DPCs into a repository is to repackage the SNF into different canisters. The direct disposal of DPCs without cutting them open and repackaging is appealing because it could be more cost-effective, reduce the complexity of fuel management operations both in and outside reactor facilities, and result in less cumulative worker dose during interim storage and handling before eventual disposal in a deep geologic repository.
The current spent nuclear fuel (SNF) management strategy includes reliance on dry storage. Utilities are meeting their interim storage needs on an individual basis with use of large-capacity dry storage casks, with a current focus on meeting existing storage and transportation requirements, as disposal requirements are not currently available. These casks are commonly known as dual-purpose (i.e., storage and transportation) canisters (DPCs). However, a small percentage of single-purpose (storage only) systems is also being used to meet storage needs. These are included under the “DPC” heading. This report investigates the postclosure criticality safety aspects of DPCs. Placing large, heavy waste packages containing DPCs into a repository for direct disposal has not yet been implemented domestically or internationally. Therefore, direct disposal of DPCs represents new engineering and scientific challenges. Some of the engineering challenges that have already been addressed include handling and placement, use of ramps vs. shafts, use of hoists, use of transport equipment, and thermal management. Additionally, some studies have been conducted in the past regarding the feasibility of direct disposal from a criticality analysis perspective and have concluded that while possible, demonstrating subcriticality over the disposal time period is a challenge. The alternative to direct disposal of DPCs into a repository is to repackage the SNF into different canisters. The direct disposal of DPCs without cutting them open and repackaging is appealing because it could be more cost-effective, reduce the complexity of fuel management operations both in and outside reactor facilities, and result in less cumulative worker dose during interim storage and handling before eventual disposal in a deep geologic repository.
Iron (Fe) (oxyhydr)oxides are well-recognized contributors to soil carbon (C) storage, but the effects of manganese (Mn) oxides on carbon storage and transformation are relatively unexplored. Here, the relative capacities of Fe and Mn oxides to bind and stabilize soil organic C were directly compared using an in-situ incubation experiment. Quartz sands coated with either poorly crystalline Mn(III/IV) oxides or Fe(III) oxides, or left uncoated, were buried in a temperate forest soil for up to one year. This data package contains processed data outputs of carbon near edge x-ray absorption fine structure spectroscopy (C NEXAFS), iron and manganese x-ray absorption near edge structure spectroscopy (XANES), and small angle neutron scattering (SANS) data collected for initial oxide-coated and uncoated quartz sands and for those buried in the temperate forest soil for 365 days.
LiMnxFe1−xPO4 (LMFP) is a promising high-voltage, thermally stable, and earth-abundant cathode material, yet its practical application is limited by interphase instability and Mn dissolution. In this work, we systematically evaluate LiMn0.6Fe0.4PO4/graphite pouch cells using three electrolyte formulations including control carbonate electrolyte, control + 2 wt% vinylene carbonate (VC), and control + 2 wt% VC + 1 wt% 1,3,2-dioxathiolane 2,2-dioxide (DTD), to establish how electrolyte composition governs interphase chemistry and long-term degradation. Electrochemical testing shows that both additives are preferentially reduced prior to ethylene carbonate (EC) during cell formation, generating robust cathode-electrolyte interphase (CEI) and solid-electrolyte interphase (SEI) layers that suppress gas evolution and raise the first-cycle coulombic efficiency to 89.3%. Additionally, the dual-additive electrolyte delivers the most stable performance, retaining over 85% capacity after 600 cycles while minimizing impedance growth under long-term cycling at C/3 and 40 °C. Soft X-ray absorption spectroscopy confirms that VC + DTD effectively suppresses electrolyte oxidation at the cathode surface, and micro-X-ray fluorescence shows substantially reduced Mn dissolution and deposition on the graphite anode. Density functional theory simulations further provided insights into the structural and energetic influences of alkoxide species on the cathode surface, proposing a Mn2+ extraction mechanism. The combined experimental and computational findings establish a mechanistic link between electrolyte composition and interphase evolution, highlighting the effectiveness of electrolyte engineering for extending the operational lifetime of LMFP-based lithium-ion batteries.
Solar induced chlorophyll fluorescence (SIF) was retrieved from high resolution reflectance spectra acquired one meter above saplings of three deciduous tree species during springtime (three weeks after leaf flush) and in late summer when foliage was mature. SIF was determined by application of the Fraunhofer Line Depth (FLD) Principal to above-canopy spectra acquired with an Analytical Spectral Devices (ASD) Fieldspec spectroradiometer (3.2 nm resolution with 1.2 nm sampling interval). SIF retrievals were made at the two atmospheric oxygen (O2) absorption features that occur in the chlorophyll fluorescence (ChlF) region (660 -780 nm). These telluric features are 02V, the broader and deeper feature centered at 760 nm, but located on the shoulder of the far-red ChlF peak at 740 nm; and 023, a narrow feature centered at 688 nm that is positioned near the red ChlF peak at 685 nm. Supporting, coincident leaf level fluorescence, reflectance, photochemical and other measurements were also made. At the leaf level, these measurements included in situ photosynthetic capacity (Pmax) and light adapted total chlorophyll fluorescence (Fs') collected at steady state under high light and controlled chamber conditions (e.g., temperature, PAR, humidity, and COz); optical properties (reflectance, transmittance, absorptance); chlorophyll and carotenoid content; specific leaf mass; carbon (C) and nitrogen (N) content; fluorescence emission spectra at multiple excitation wavelengths; the ChlF contribution to red (R) and far-red (FR) reflectance; fluorescence imagery; and fluorescence excitation-emission matrices (EEMs). The tree species examined were tulip poplar (Liriodendron tulipifera L.), red maple (Acer rubrum L.), and sweetgum (Liquidambar styraczflua L.), and each had been provided four levels of N augmentation (0, 19, 37, and 75 kg Nhectare seasonally) to simulate atmospheric deposition from air pollution. Whole-plant SIF measurements of these species were compared with SIF estimates derived using FluorMOD, a radiative transfer model that includes fluorescence properties of foliage, when provided with our supporting measurements. Simulated values for SIF were also compared with similar estimates made over three years for corn (Zea mays L) crops under N treatments (20, 50,70, and 140 kg Nhectare) and with corn and pepper (Capsicum annuum L.) plants provided dimethyl urea (DCMU, 0 and 5 x 10" M) which were grown in pots and grouped in artificial canopies for spectral measurements. For near-surface measurements of healthy and stressed vegetation, red SIF retrieved at 688 nm (023) varied between 2-7 mW/m(exp 2)/nm/sr while far-red SIF retrieved at 760 nm (O2A) varied between 0.5 and 4.0 mW/m(exp 2)/nm/sr. Typical values for the SIF red/far-red ratio ranged between 1.75 and 4.0. Relationships of SIF to spectral reflectance indices and foliar photochemical indices were examined, such as photosynthetic light use efficiency. Initial investigations of the variability in these measurements at the same leaf temperature for sunlit and shaded foliage showed us that shaded foliage produced higher ChlF and light use efficiency. Other factors that affect SIF determinations are discussed. These results will assist in determine the expected intensity of the SIF signal from vegetation near the surface, as well as to identify enhancements needed for FluorMOD (or other such models), and will assist in determining relationships of SIF to reflectance indices and carbon dynamics.
Aqueous Zn-ion batteries (AZIBs) are promising alternatives to lithium-ion batteries in stationary storage. However, limited storage capacity and cyclic life impede their large-scale implementation. In this study, we report reversible electrochemical insertion of multi-ions into sodium vanadate (NaV 3 O 8 ) cathode materials for AZIBs, achieving a maximum storage capacity of 450 mAh g –1 at 0.05 A g –1 and a capacity retention of 82% after 500 cycles at 0.4 A g –1 . In addition to Zn 2+ and H + insertion, in situ X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) collectively provide explicit evidence on vanadyl ions (VO 2+ ) conversion–intercalation at the NaV 3 O 8 cathode, showing the deintercalation of VO 2+ from NaV 3 O 8 and the consequent conversion of VO 2+ into V 2 O 5 on charging, and vice versa on discharging. Our study is the first to report on the cation conversion–intercalation mechanism in AZIBs. This reversible multi-ion storage mechanism provides a design principle for developing high-capacity aqueous electrode materials by engaging both the intercalation and conversion of charge carriers.
In order to provide important details concerning the adsorption reactions of Sr, batch reactions and a set of both ex situ and in situ Grazing Incidence X-ray Absorption Fine Structure (GIXAFS) adsorption experiments were completed on powdered TiO 2 and on rutile(110), both reacted with either SrCl 2 or SrCO 3 solutions. TiO 2 sorption capacity for strontium (Sr) ranges from 550 ppm (SrCl 2 solutions, second order kinetics) to 1400 ppm (SrCO 3 solutions, first order kinetics), respectively, and is rapid. Sr adsorption decreased as a function of chloride concentration but significantly increased as carbonate concentrations increased. In the presence of carbonate, the ability of TiO 2 to remove Sr from the solution increases by a factor of ~4 due to rapid epitaxial surface precipitation of an SrCO 3 thin film, which registers itself on the rutile(110) surface as a strontianite-like phase (d-spacing 2.8 Å). Extended X-ray Absorption Fine Structure (EXAFS) results suggest the initial attachment is via tetradental inner-sphere Sr adsorption. Moreover, adsorbates from concentrated SrCl 2 solutions contain carbonate and hydroxyl species, which results in both inner- and outer-sphere adsorbates and explains the reduced Sr adsorption in these systems. These results not only provide new insights into Sr kinetics and adsorption on TiO 2 but also provide valuable information concerning potential improvements in effluent water treatment models and are pertinent in developing treatment methods for rutile-coated structural materials within nuclear power plants.
Explore the source record for details and available documents.
Zinc-blende (ZB) cadmium selenide (CdSe) nanoplatelets (NPLs) have drawn increasing attention as an ideal condensed-phase material for facilitating photon-to-spin transduction in quantum networks. Yet, a systematic investigation of their fidelity in converting circularly polarized light (CPL) to exciton spin polarization as a function of excitation wavelength is lacking. Here, this work demonstrates using time-resolved transient absorption (TA) spectroscopy combined with density functional theory calculations that ZB CdSe NPLs exhibit wavelength-dependent CPL-induced spin polarization. The capacity of CPL to inject spin polarization is maximized for resonant excitation of band-edge valence-to-conduction band (VB/CB) transitions, and the degree to which CPL induces spin polarization can be modified for non-resonant excitation wavelengths as excitation occurs at k-points away from the Γ point from VB states with varying degrees of mixed heavy-hole (HH) and light-hole (LH) characters. Furthermore, it is highlighted that spin polarization within the LH exciton (LX) population created from resonant LH/CB excitation is retained upon LX → HH exciton (HX) relaxation due to the slow electron spin-flip rate (~1.1 ps) compared to the LH → HH inter-band relaxation rate (~200 fs).
Direct air capture (DAC) of CO 2 is a negative emission technology that utilizes sorbents requiring a regeneration step for repeated ab(/d)sorption–desorption cycles. Here we report an unconventional approach to desorb captured CO 2 from a porous sorbent using radiofrequency (RF) irradiation for dielectric heating and targeted energy transfer, thus enabling modularity and promoting renewable energy input. Regeneration of composites of functional ionic liquid and metal–organic framework with high CO 2 capacity and enhanced transport is demonstrated under conditions relevant to DAC. RF-assisted dielectric heating at the megahertz frequency range shows effective absorption of electromagnetic energy and consequently rapid release of the captured CO 2 .