Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerometers.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Measurement and Analysis of the Extreme Physical Shock Environment Experienced by Crane-Mounted Radiation Detection Systems

At ports of entry, radiation detectors could be mounted on container gantry crane spreaders to monitor cargo containers entering and leaving the country. These detectors would have to withstand the extreme physical conditions experienced by these spreaders during normal operations. Physical shock data from the gable ends of a spreader were recorded during the loading and unloading of a cargo ship by twohard mounted PCB Piezotronics model 340A50 accelerometers and two Lansmont SAVER 9X30 units(with padding). The majority of large shocks were observed in the vertical direction. The Lansmont units recorded mean shocks of 22.215 ±1.174and 23.776 ±1.140g, while the PCB accelerometers recorded mean shocks of 31.608 ±1.798and 37.072 ±2.015g in this direction. Maximum shocks were as high as 118.854 g. A scatter plot of observed peak acceleration versus velocity change is presented to allow comparison with the damage boundary curve for any planned instrumentation for future systems. Furthermore, it is hoped that the results of this research will aid in the design of future crane-mounted systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Creation of a prototype biomimetic fish to better understand impact trauma caused by hydropower turbine blade strikes

Biomimetic model organisms could be useful surrogates for live animals in many applications if the models have sufficient biofidelity. One such application is for use in field and laboratory tests of fish mortality associated with passage through hydropower turbines. Laboratory trials suggest that blade strikes are especially injurious and often causes mortality when fish are struck by thinner blades moving at higher velocities. Dose-response relationships have been created from these data, but the exact relationship between fish mortality and the actual forces enacted on fish during simulated blade strike testing remains unknown. Here, we describe the methods used to create a prototype biomimetic model fish composed of ballistic gelatin and covered with a surrogate skin to better approximate the biomechanical properties of a fish body. Frozen fish were scanned with high-fidelity laser scanners, and a 3D-printed, reusable mold was created from which to cast our gelatin model. Computed tomography scan data, imaged directly or taken from online data repositories, were also successfully used to create CAD models for use in additive manufacturing of molds. One 3-axis accelerometer was embedded into the gelatin to compare accelerometer data to dose-response data from previous laboratory research on live fish. The resulting model ( i.e. , Gelfish) had a statistically indistinguishable tissue durometer to that of real fish tissue and preliminary blade strike impact testing suggested its overall flexibility was similar to that of live fish. Gelfish was designed with biofidelity as its guiding principle and our results suggest initial experimentation was successful. Future research will include replication of initial Gelfish test results, quantitative measurement of model flexibility relative to real fish, and inclusion of surrogate skeletal structures to enhance biofidelity. Use of more sophisticated sensors would also better quantify the physical forces of blade strike impact and help determine how said forces correlate with rates of mortality observed during tests on live fish.

36 MATERIALS SCIENCE↗

An Overview of the Source Physics Experiment at the Nevada National Security Site (SPE-N)

Understanding the changes in seismic energy as it travels from the near field to the far field is the ultimate goal in monitoring for explosive events of interest. This requires a clear understanding of explosion phenomenology as it relates to seismic, infrasound, and acoustic signals. Although there has been much progress in modeling these phenomena, this has been primarily based in the empirical realm. As a result, the logical next step in advancing the seismic monitoring capability of the United States is to conduct field tests that can expand the predictive capability of the physics-based modeling currently under development. The Source Physics Experiment at the Nevada National Security Site (SPE-N) is the first step in this endeavor to link the empirically based with the physics-based modeling. This is a collaborative project between National Security Technologies (NSTec), Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), the Defense Threat Reduction Agency (DTRA), and the Air Force Technical Applications Center (AFTAC). The test series require both the simple and complex cases to fully characterize the problem, which is to understand the transition of seismic energy from the near field to the far field; to understand the development of S-waves in explosives sources; and how anisotropy controls seismic energy transmission and partitioning. The current series is being conducted in a granite body called the Climax Stock. This location was chosen for several reasons, including the fairly homogenous granite; the location of previous nuclear tests in the same rock body; and generally the geology has been well characterized. The simple geology series is planned for 7 shots using conventional explosives in the same shot hole surrounded by Continuous Reflectometry for Radius vs. Time Experiment (CORRTEX), Time of Arrival (TOA), Velocity of Detonation (VOD), down-hole accelerometers, surface accelerometers, infrasound, and a suite of seismic sensors of various frequency bands from the near field to the far field. This allows for the use of a single test bed in the simple geology case instead of multiple tests beds to obtain the same results. The shots are planned at various depths to obtain a Green’s function, scaled-depth of burial data, nominal depth of burial data and damage zone data. SPE1-N was conducted in May 2011 as a 220 lb (100 kg) TNT equivalent calibration shot at a depth of 180 ft (55 m). SPE2-N was conducted in October 2011 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m). SPE3-N was conducted in July 2012 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m) in the damaged zone. Over 400 data channels were recorded for each of these shots and data recovery was about 95% with high signal to noise ratio. Once the simple geology site data has been utilized, a new test bed will be developed in a complex geology site to test these physics based models. Ultimately, the results from this project will provide the next advances in the science of monitoring to enable a physics-based predicative capability.

Source record↗

Methods for forewarning of critical condition changes in monitoring civil structures

Sensor modules (12) including accelerometers (20) are placed on a physical structure (10) and tri-axial accelerometer data is converted to mechanical power (P) data (41) which then processed to provide a forewarning (57) of a critical event concerning the physical structure (10). The forewarning is based on a number of occurrences of a composite measure of dissimilarity (C.sub.i) exceeding a forewarning threshold over a defined sampling time; and a forewarning signal (58) is provided to a human observer through a visual, audible or tangible signal. A forewarning of a structural failure can also be provided based on a number of occurrences of (C.sub.i) above a failure value threshold.

47 OTHER INSTRUMENTATION↗

Haptic seat for fuel economy feedback

A process of providing driver fuel economy feedback is disclosed in which vehicle sensors provide for haptic feedback on fuel usage. Such sensors may include one or more of a speed sensors, global position satellite units, vehicle pitch/roll angle sensors, suspension displacement sensors, longitudinal accelerometer sensors, throttle position in sensors, steering angle sensors, break pressure sensors, and lateral accelerometer sensors. Sensors used singlely or collectively can provide enhanced feedback as to various environmental conditions and operating conditions such that a more accurate assessment of fuel economy information can be provided to the driver.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Controlled Pyroshock Transients Can Be Used To Better Match Operational Shock Transients and Improve Shock Analysis and Testing

SRS analysis and testing to SRS is known to be conservative since SRS is generated from maxi-max shock transient data, maximum peaks are assumed to occur for each mode simultaneously, and the structural dynamics are not accounted for between the shock source and the test article. Knowing the structural dynamics of a shock test setup it is possible to subscribe a force shock transient applied at a particular strike location and direction to achieve a desired shock transient at a test reference accelerometer. The SRS at this test accelerometer reference location can be used to compare to the reference SRS, but the key reference is the shock transient not the SRS, which should lead to more realistic shock testing that better matches operational shock transient data and reduces artificial test failures that don’t occur in operational usage. The desired test shock transient should match operational shock transients. As such, the test shock transient should look similar to the operational shock transient and have similar positive and negative peaks, the same shape, and the same duration. Many shock transients can be created that satisfy an SRS, but better control of these shock transient parameters is needed to better match operational shock transients so that more realistic and less conservative shock testing can be performed. Three different shock transients are presented that satisfy a given SRS and the results are compared for an electronic board (test article) attached to a circular shock resonance test plate.

SRS, shock transient, frequency domain, FRF↗

Multi-Sensor Data Acquisition System for Process Monitoring

Idaho National Laboratory is building a new nuclear fuel cycle test bed. This fuel cycle test bed named “Beartooth” will give researchers the opportunity to study the nuclear fuel cycle process. The process operations include the use of centrifugal contactors and process flow for the purification of special nuclear material recovery in used fuel. This new research facility has the need to use non-traditional measurement sensors to determine the state-of-health of the solvent extraction process. These non-traditional sensors can also enhance nuclear nonproliferation supervision and other activities. The non-traditional sensors include accelerometers, acoustic, current, flow, colorimetric, temperature, pH and conductivity. The challenge behind deploying all these sensors, is the need for fast and reliable data collection. The data acquisition system (DAQ) needs to be capable of recording up to 12 accelerometers and/or acoustic microphones simultaneously at rates up to 12.8 kSamples/second/channel. This requires the need for a strong architecture and data collection solution. This summary identifies the system architecture, DAQ, and sensors needed to support non-traditional measurements in a solvent extraction process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling and Analysis of a One-Third Scale Used Nuclear Fuel Package 30 cm Drop

This paper compares finite element models of used nuclear fuel package drop tests to actual test data recorded in a recent test campaign. In December of 2018, the US Department of Energy collaborated with Equipos Nucleares S.A, S.M.E (ENSA) and Bundesanstalt für Materialforschung und -prüfung (BAM) to perform 30 cm horizontal drop tests of a one-third scale model of the ENSA ENUN 32P dual-purpose used nuclear fuel package. The third-scale test package included a third-scale basket and simulated third-scale fuel assemblies that were instrumented with accelerometers to measure their individual impact responses. Two horizontal package drop tests were performed, one with the basket cells oriented parallel and perpendicular to the impact surface, and one with the basket rotated 45 degrees to change the relative orientation with the impact surface. This paper describes the modeling and analysis that supported the development of the test and instrumentation plan, such as which fuel assemblies should be instrumented and at what locations on each fuel assembly should the accelerometers be placed. Pre-test predictions based on finite element modelling are discussed, and a comparison against the actual test data is made. Post-test analysis and model refinement are also discussed, with the goal of identifying best practices and lessons learned. A separate paper by Kalinina et al., to be presented at this conference, more fully describes the test configuration and test results. This paper is focused on the numerical modeling that supported the test and the lessons learned about realistically modeling this type of physical test.

Klymyshyn, Nicholas A.↗

A Chaos Theoretic Approach to Animal Activity Recognition

Animal activity is a descriptor that can be potentially used to track the health and well-being, which is obviously very important to improve the management process and productivity of farms. This paper deals with an animal behavior recognition problem using a chaos theory approach where we adopt such a technique for automatic classification of calves behavioral states. Two main mutually exclusive behaviors are of interest, namely, lying and standing/walking with six possible activities: feeding, drinking water, drinking milk, playing, rumination, and neutral. The time series generated by ear-tags with a 3D-accelerometer after a wavelet denoising transformation and frequency stabilization are treated as representations of the nonlinear dynamical system. The dynamical system of a certain animal state exhibits specific strange attractor in a phase space. A characterization of such an attractor is performed through metric, dynamic, and topological invariants including Lyapunov exponent, correlation dimension, length of a phase trajectory, sum of edges forming a convex hull and others. These measures are used as a feature vector for the subsequent classification. In a cross validation scheme, six classifiers are built on each training set, and the hyper-parameters are optimized using an inner validation set. The classifier that reaches the highest accuracy on the inner validation set is used to classify the outer validation set. It is shown that this approach can be useful at predicting activity states as an alternative methodology for the animal behavior state recognition problem with acceptable classification accuracy. Furthermore it is possible to include this procedure as part of an ensemble method in machine learning where a combination of different models is used.

97 MATHEMATICS AND COMPUTING↗

Characterization of ZnO nanoparticle suspension in water: Effectiveness of ultrasonic dispersion

Suspensions of ZnO nanoparticles in water were prepared with the two-step powder dispersion process using several methods of ultrasonication. The dispersion of ZnO was found to proceed by a fragmentation process. with minimum achievable particle size in the range 50 to 300 nm. This is consistent with other oxide nanopowder systems, in which most primary particulates still remain in hardened aggregates that cannot be further reduced. A submersible accelerometer probe was developed and used to measure the relative ultrasonic energy held in the liquid for the various ultrasonication methods. oscillation at the expected frequencies was identified in each case, with strong variability at different locations in the liquid volume.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Automated system for the calibration of magnetometers

A completely nonmagnetic calibration platform has been developed and constructed at DTU Space (Technical University of Denmark). It is intended for on-site scalar calibration of high-precise fluxgate magnetometers. An enhanced version of the same platform is being built at the Czech Technical University. There are three axes of rotation in this design (compared to two axes in the previous version). The addition of the third axis allows us to calibrate more complex devices. An electronic compass based on a vector fluxgate magnetometer and micro electro mechanical systems (MEMS) accelerometer is one example. The new platform can also be used to evaluate the parameters of the compass in all possible variations in azimuth, pitch, and roll. The system is based on piezoelectric motors, which are placed on a platform made of aluminum, brass, plastic, and glass. Position sensing is accomplished through custom-made optical incremental sensors. The system is controlled by a microcontroller, which executes commands from a computer. The properties of the system as well as calibration and measurement results will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large amplitude dynamics of micro-/nanomechanical resonators actuated with electrostatic pulses

In the field of resonant nano-electro-mechanical system (NEMS) design, it is a common misconception that large-amplitude motion, and thus large signal-to-noise ratio, can only be achieved at the risk of oscillator instability. In the present paper, we show that very simple closed-loop control schemes can be used to achieve stable large-amplitude motion of a resonant structure even when jump resonance (caused by electrostatic softening or Duffing hardening) is present in its frequency response. We focus on the case of a resonant accelerometer sensing cell, consisting of a nonlinear clamped-clamped beam with electrostatic actuation and detection, maintained in an oscillation state with pulses of electrostatic force that are delivered whenever the detected signal (the position of the beam) crosses zero. We show that the proposed feedback scheme ensures the stability of the motion of the beam much beyond the critical Duffing amplitude and that, if the parameters of the beam are correctly chosen, one can achieve almost full-gap travel range without incurring electrostatic pull-in. These results are illustrated and validated with transient simulations of the nonlinear closed-loop system.

47 OTHER INSTRUMENTATION↗

Nanograss and nanostructure formation on silicon using a modified deep reactive ion etching

Silicon nanograss and nanostructures are realized using a modified deep reactive ion etching technique on both plane and vertical surfaces of a silicon substrate. The etching process is based on a sequential passivation and etching cycle, and it can be adjusted to achieve grassless high aspect ratio features as well as grass-full surfaces. The incorporation of nanostructures onto vertically placed parallel fingers of an interdigital capacitive accelerometer increases the total capacitance from 0.45 to 30 pF. Vertical structures with features below 100 nm have been realized.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements.Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken.This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning Laser Doppler Vibrometer Measurements Inside Helicopter Cabins in Running Conditions: Problems and Mock-up Testing

The present work deals with the analysis of problems and potentials of laser vibrometer measurements inside helicopter cabins in running conditions. The paper describes the results of a systematic measurement campaign performed on an Agusta A109MKII mock-up. The aim is to evaluate the applicability of Scanning Laser Doppler Vibrometer (SLDV) for tests in simulated flying conditions and to understand how performances of the technique are affected when the laser head is placed inside the cabin, thus being subjected to interfering inputs. Firstly a brief description of the performed test cases and the used measuring set-ups are given. Comparative tests between SLDV and accelerometers are presented, analyzing the achievable performances for the specific application. Results obtained measuring with SLDV placed inside the helicopter cabin during operative excitation conditions are compared with those performed with the laser lying outside the mock-up, these last being considered as 'reference measurements'. Finally, in order to give an estimate of the uncertainty level on measured signals, a study linking the admitted percentage of noise content on vibrometer signals due to laser head vibration levels will be introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contact Versus Non-Contact Measurement of a Helicopter Main Rotor Composite Blade

The dynamic characterization of lightweight structures is particularly complex as the impact of the weight of sensors and instrumentation (cables, mounting of exciters...) can distort the results. Varying mass loading or constraint effects between partial measurements may determine several errors on the final conclusions. Frequency shifts can lead to erroneous interpretations of the dynamics parameters. Typically these errors remain limited to a few percent. Inconsistent data sets however can result in major processing errors, with all related consequences towards applications based on the consistency assumption, such as global modal parameter identification, model-based damage detection and FRF-based matrix inversion in substructuring, load identification and transfer path analysis [1]. This paper addresses the subject of accuracy in the context of the measurement of the dynamic properties of a particular lightweight structure. It presents a comprehensive comparative study between the use of accelerometer, laser vibrometer (scanning LDV) and PU-probe (acoustic particle velocity and pressure) measurements to measure the structural responses, with as final aim the comparison of modal model quality assessment. The object of the investigation is a composite material blade from the main rotor of a helicopter. The presented results are part of an extensive test campaign performed with application of SIMO, MIMO, random and harmonic excitation, and the use of the mentioned contact and non-contact measurement techniques. The advantages and disadvantages of the applied instrumentation are discussed. Presented are real-life measurement problems related to the different set up conditions. Finally an analysis of estimated models is made in view of assessing the applicability of the various measurement approaches for successful fault detection based on modal parameters observation as well as in uncertain non-deterministic numerical model updating.

36 MATERIALS SCIENCE↗

Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations

The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s{sup 2}). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple go/no-go test for subcritical damage in body armor panels

The development of a simple test for subcritical damage in body armor panels using pressure-sensitive dye-indicator film has been performed and demonstrated effective. Measurements have shown that static indicator levels are accurately reproduced in dynamic loading events. Impacts from hard blunt impactors instrumented with an accelerometer and embedded force transducer were studied. Reliable correlations between the indicator film and instrumented impact force are shown for a range of impact energies. Force and acceleration waveforms with corresponding indicator film results are presented for impact events onto damaged and undamaged panels. We find that panel damage can occur at impact levels far below the National Institute of Justice acceptance test standard.

42 ENGINEERING↗