An Integrated Theory for Predicting the Hydrothermomechanical Response of Advanced Composite Structural Components

An integrated theory is developed for predicting the hydrothermomechanical (HDTM) response of fiber composite components. The integrated theory is based on a combined theoretical and experimental investigation. In addition to predicting the HDTM response of components, the theory is structured to assess the combined hydrothermal effects on the mechanical properties of unidirectional composites loaded along the material axis and off-axis, and those of angleplied laminates. The theory developed predicts values which are in good agreement with measured data at the micromechanics, macromechanics, laminate analysis and structural analysis levels.

Chamis, C. C.↗

Study on utilization of advanced composites in commercial aircraft wing structures, volume 2

A plan is defined for a composite wing development effort which will assist commercial transport manufacturers in reaching a level of technology readiness where the utilization of composite wing structure is a cost competitive option for a new aircraft production plan. The recommended development effort consists of two programs: a joint government/industry material development program and a wing structure development program. Both programs are described in detail.

Sakata, I. F.↗

Effects of Moisture Profiles and Laminate Configuration on the Hygro Stresses in Advanced Composites

An integrated hygrothermo-mechanical theory was used to predict the effects of three moisture profiles on the ply hygro stresses in angleplied laminates. The moisture profiles were linear, parabolic and hyperbolic. Moisture content varied from 1 percent in the exposed ply to zero in the protected ply. The angleplied laminates were of two generic configurations. The results obtained are summarized graphically to illustrate the effects of both moisture profile and laminate configuration. The results indicate that ply transverse tensile hygro stresses may reach sufficiently high magnitudes to cause transply cracking.

Chamis, C. C.↗

A study of the effects of long-term exposure to fuels and fluids on the behavior of advanced composite materials

The Task 1 (thirty-six-month) and Task 2 (twelve-month) exposure of composite materials to fuel and fluid environments are reported. Narmco T300/5209 (Task 1) shows no significant degradation. Slightly lower mechanical properties were obtained from fuel/water immersion exposure of this material. Kevlar 49/2544 (also Task 1) exhibits significant drop in short-beam shear when exposed to fuel/water immersion. Task 2 materials (T300/5208, Kevlar 49 fabric/5209, and Kevlar 49 fibers) have not shown any significant mechanical property degradation to date.

Hendricks, C. L.↗

Environmental effects on advanced composites

The development of titanium matrix composites for elevated temperature applications was investigated. General solutions for treating diffusion in multiphase multicomponent systems were studied. Graphite polyimide composites were characterized with respect to mechanical property degradation by moisture.

Unnam, J.↗

Advanced composites - Future space applications

Potential applications of composite materials in kilometer-size space systems are reviewed noting the advent of the NASA Space Transportation System. Antenna configurations are considered with reference to the 10-m-diam wrapped-rib antenna used on the ATS-6 satellite, a 15-m-diam graphite/epoxy wrapped-rib antenna, and a folding planar array synthetic aperture radar antenna. The heliogyro solar sail concept is presented along with solar power station designs based on either photovoltaic arrays or parabolic arrays of flat facets. The development of beam fabricators is described.

Boundy, R. A.↗

Interim results of long-term environmental exposures of advanced composites for aircraft applications

Interim results from a number of ongoing, long-term environmental effects programs for composite materials are reported. The flight service experience is evaluated for 142 composite aircraft components after more than five years and one million successful component flight hours. Ground-based outdoor exposures of composite material coupons after 3 years of exposure at five sites have reached equilibrium levels of moisture pickup which are predictable. Solar ultraviolet-induced material loss is discussed for these same exposures. No significant degradation has been observed in residual strength for either stressed or unstressed specimens, or for exposures to aviation fuels and fluids.

Pride, R. A.↗

Effects of moisture profiles and laminate configuration on the hygro stress in advanced composites

A theoretical investigation was performed using a recently developed integrated theory for predicting the hygrothermomechanical response to investigate the effects of three different moisture profiles on the ply hygro stresses in angleplied laminates. The moisture profiles were linear, parabolic and hyperbolic varying from 1 percent at the exposed ply to '0' percent in the protected ply. The angleplied laminates were of two generic configurations. The results obtained are summarized graphically to illustrate the effects of both moisture profile and laminate configuration.

Chamis, C. C.↗

Advanced composite aileron for L-1011 transport aircraft, task 1

Structural design and maintainability criteria were established and used as a guideline for evaluating a variety of configurations and materials for each of the major subcomponents. From this array of subcomponent designs, several aileron assemblies were formulated and analyzed. The selected design is a multirib configuration with sheet skin covers mechanically fastened to channel section ribs and spars. Qualitative analysis of currently available composite material systems led to the selection of three candidate materials on which comparative structural tests were conducted to measure the effects of environment and impact damage on mechanical property retention. In addition, each system was evaluated for producibility characteristics. From these tests, Thornel 300/5208 unidirectional tape was selected for the front spar and covers, and Thornel 300 fabric/5208 was chosen for the ribs.

Griffin, C. F.↗

A study of the effects of long-term exposure to fuels and fluids on the behavior of advanced composite materials

The periodic testing and evaluation of graphite/epoxy and Kevlar/epoxy material systems after subjecting test specimens to prolonged exposure to several laboratory-controlled environments deemed typical of normal aircraft operations is discussed. It is noted that specimen immersion in water or water-based fluids resulted in the greatest effect on the mechanical properties tested. Also, the environmental fluids showed a tendency to affect Kevlar/epoxy systems at an earlier exposure period than the graphite/epoxy systems. Results also indicate mechanical property strength retention generally being lower for the Kevlar/epoxy systems when compared to the corresponding graphite/epoxy systems in similar environments, after prolonged exposure.

Tanimoto, E. Y.↗

Study of fatigue durability of advanced composite materials under conditions of accelerated loading

The effect of temperature on the tension-tension fatigue life of the T300/5208 graphite/epoxy angle-ply laminate system was investigated in an effort to develop an acceptable and reliable method of accelerated loading. Typical S log sub 10 N curves were determined experimentally at 25 C, 75 C, and 115 C. The time-temperature superposition principle was employed to find the shift factors of uniaxial fatigue strength, and a general linear equation of S log sub 10 N for shifting purpose was established. The combined techniques of cyclic creep measurements and optical microscopy upon fatigue failure allow some assessment of the possible physical basis of S log 10 N curve shifting. Before fatigue, the laminates at all test temperatures and stress levels undergo a unique damage mechanism during fatigue loading. It is concluded that an accelerated loading method is feasible.

Shih, H. M.↗

Sonic fatigue testing of an advanced composite aileron

The sonic fatigue test program to verify the design of the composite inboard aileron for the L-1011 airplane is described. The composite aileron is fabricated from graphite/epoxy minisandwich covers which are attached to graphite/epoxy front spar and ribs, and to an aluminum rear spar with fasteners. The program covers the development of random fatigue data by means of coupon testing and modal studies on a representative section of the composite aileron, culminating in the accelerated sonic fatigue proof test. The composite aileron sustained nonlinear panel vibration during the proof test without failure. Viscous damping coefficients as low as 0.4% were measured on the panels. The effects of moisture conditioning and elevated temperature on the random fatigue life of both undamaged and impact damaged coupons were investigated. The combination of impact damage, moisture, and a 180 F temperature could reduce the random fatigue life by 50%.

Soovere, J.↗

Advanced composite elevator for Boeing 727 aircraft, volume 2

Preliminary design activity consisted of developing and analyzing alternate design concepts and selecting the optimum elevator configuration. This included trade studies in which durability, inspectability, producibility, repairability, and customer acceptance were evaluated. Preliminary development efforts consisted of evaluating and selecting material, identifying ancillary structural development test requirements, and defining full scale ground and flight test requirements necessary to obtain Federal Aviation Administration (FAA) certification. After selection of the optimum elevator configuration, detail design was begun and included basic configuration design improvements resulting from manufacturing verification hardware, the ancillary test program, weight analysis, and structural analysis. Detail and assembly tools were designed and fabricated to support a full-scope production program, rather than a limited run. The producibility development programs were used to verify tooling approaches, fabrication processes, and inspection methods for the production mode. Quality parts were readily fabricated and assembled with a minimum rejection rate, using prior inspection methods.

Chovil, D. V.↗

Advanced composite aileron for L-1011 transport aircraft: Ground tests and flight evaluation

A composite aileron and a metal aileron were subjected to a series of comparative stiffness and vibration tests. These tests showed that the stiffness and vibration characteristics of the composite aileron are similar to the metal aileron. The first composite ground test article was statically tested to failure which occurred at 139 percent of design ultimate load. The second composite ground test article was tested to verify damage tolerance and fail-safe characteristics. Visible damage was inflicted to the aileron and the aileron was subjected to one lifetime of spectrum fatigue loading. After conducting limit load tests on the aileron, major damage was inflicted to the cover and the aileron was loaded to failure which occurred at 130 percent of design ultimate load. A shipset of composite ailerons were installed on Lockheed's L-1011 flight test aircraft and flown. The composite aileron was flutter-free throughout the flight envelope.

Griffin, C. F.↗

Advanced composite aileron for L-1011 transport aircraft: Design and analysis

Detail design of the composite aileron has been completed. The aileron design is a multi-rib configuration with single piece upper and lower covers mechanically fastened to the substructure. Covers, front, spar and ribs are fabricated with graphite/epoxy tape or fabric composite material. The design has a weight savings of 23 percent compared to the aluminum aileron. The composite aileron has 50 percent fewer fasteners and parts than the metal aileron and is predicted to be cost competitive. Structural integrity of the composite aileron was verified by structural analysis and an extensive test program. Static, failsafe, and vibration analyses have been conducted on the composite aileron using finite element models and specialized computer programs for composite material laminates. The fundamental behavior of the composite materials used in the aileron was determined by coupon tests for a variety of environmental conditions. Critical details of the design were interrogated by static and fatigue tests on full-scale subcomponents and subassemblies of the aileron.

Griffin, C. F.↗

Noise transmission characteristics of advanced composite structural materials

Theoretical and experimental results from a study of noise transmission properties of large unstiffened panels which simulated aircraft outer skins and interior trim are reported. The investigation was performed to define the effects of composite structures on fuselage noise transmission relative to the transmissivity of aluminum structures. One-third octave band measurements were obtained in a two-room facility for measuring transmission loss. Center frequencies of at least 100 Hz were used, and 14 different composite panels, including samples of Kevlar, fiberglass, and graphite, were examined. Details of the composites fabrication techniques are provided, and an infinite panel theory transmission loss model is defined. The flexural rigidities of tape and fabric panels are calculated, as are the transmission losses, the coincidence frequency, and the critical frequency. The theory was determined to be accurate to within 1 dB of the measured transmission loss for mass-controlled specimens.

Roussos, L. A.↗

Static and damage tolerance tests of an advanced composite vertical fin for L-1011 aircraft

This paper recounts the significant events which took place during the structural verification testing of two graphite/epoxy material, full-size vertical stabilizers. The ground test articles were tested to a high bending dynamic lateral gust condition. The first unit failed during static testing at 98 percent Design Ultimate Load. Failure began within the front spar cap. A detailed review of the failure was performed to identify all possible modes. This review resulted in a 'production line' type fix being designed for incorporation in the second ground test article prior to installation in the test fixture. The modified second unit sustained 106 percent of Design Ultimate Load without incident. One lifetime (36,000 flights) of damage tolerance testing was accomplished with the specimen purposely damaged at five locations. A fail-safe loading was performed successfully after simulating lightning strike damage to the fin box cover. A large area repair was substantiated by completing a second lifetime of spectrum loadings. The residual static strength was determined to be 119.7 percent of Design Ultimate Load.

Dorward, F.↗