Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Exploring the Focusing Mechanism of the NuMI Horn Magnets

Neutrinos at the Main Injector (NuMI) is a project at Fermilab that provides an intense beam of neutrinos used by a number of experiments. NuMI creates a beam of pions that decay into neutrinos, muons, and other particles. Muons are registered by the muon monitors. Magnetic horns are the key elements of the NuMI beam line. This paper uses the muon beam profile observed at the muon monitors to study the NuMI horn focusing mechanism. It is found that the horn magnet generates dipole and quadrupole fields to focus pions. This suggests that the optics of the horn magnet are predominantly linear. Our study shows that the muon beam profile accurately detects the horn current within 0.05%.

43 PARTICLE ACCELERATORS↗

Control of domain wall pinning by localised focused Ga {sup +} ion irradiation on Au capped NiFe nanowires

Understanding domain wall pinning and propagation in nanowires are important for future spintronics and nanoparticle manipulation technologies. Here, the effects of microscopic local modification of the magnetic properties, induced by focused-ion-beam intermixing, in NiFe/Au bilayer nanowires on the pinning behavior of domain walls was investigated. The effects of irradiation dose and the length of the irradiated features were investigated experimentally. The results are considered in the context of detailed quasi-static micromagnetic simulations, where the ion-induced modification was represented as a local reduction of the saturation magnetization. Simulations show that domain wall pinning behavior depends on the magnitude of the magnetization change, the length of the modified region, and the domain wall structure. Comparative analysis indicates that reduced saturation magnetisation is not solely responsible for the experimentally observed pinning behavior.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The collimation of intense relativistic electron beams generated by ultra-intense femtosecond laser in nanometer-scale solid fiber array

A scheme to collimate the ultra-intense laser generated MeV electrons by nanometer-scale solid fiber array is proposed. Unlike previous resistivity-structured target schemes, not the magnetic field but the electric field due to the anisotropic resistivity acts to collimate the divergent fast electrons. This concept is well supported by analytical estimation and numerical calculation. The measurements of collimated MeV electron beams at rear of carbon nanotube arrays irradiated by intense femtosecond laser show the viability of this scheme. These results indicate that potential applications include radiography, fast electron beam focusing, and perhaps the electron collimation for fast ignition of inertial confined fusion.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Experimental studies in magnetically induced transverse force-frequency effect in thin quartz microresonators

In this work, the transverse force-frequency sensitivity of magnetostrictive Metglas{sup ®} (Fe{sub 85}B{sub 5}Si{sub 10}) thin film coated AT-cut thickness shear mode quartz thin plate microresonator (500 μm × 500 μm × 19 μm) is experimentally measured and modeled in Lagrangian formulation by coupling magnetostrictive deformation equations with the basic plate equations from the theory of small deformation. The quartz plate resonator is fabricated by micromachining techniques and released into fixed-free structure using focused ion beam milling. Application of a magnetic field results in the out-of-plane bending of the structure due to elastic coupling between the magnetostrictive Metglas{sup ®} and quartz resonator layers. As a result of the transverse loading and out-of-plane bending, the admittance characteristics of the resonator shifts, and these shifts are recorded in real time utilizing a network analyzer. The sensitivity is experimentally measured to be 162.3 mdeg/Oe for phase, corresponding to a frequency sensitivity of Δf/H = 11 Hz/Oe. The equivalent force-frequency sensitivity can then be calculated as 2.36 μN/Hz using the developed model. The coupled domain analysis fits well with the experimental data. Further reduction of quartz thickness and optimization of the thickness ratio of the magnetostrictive to quartz layers offers the possibility of exploiting the stress sensitivity of plate microresonators as sensitive magnetic field sensors capable of low nanoTesla to picoTesla level magnetic flux densities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum tube

Here, we report the experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum electronic device, which uses an over-moded spherical sector output cavity. In this device, a pencil electron beam is helically deflected in a transverse deflecting cavity before entering the output cavity. No magnetic field is required to focus or guide the beam. We built and tested a proof-of-principle device with an output frequency of 57.12 GHz. The measured peak power was 52.67 W at the 5th harmonic of the drive frequency. Power at the 4th, 6th, and 7th harmonics was 33.28 dB lower than that at the 5th harmonic.

43 PARTICLE ACCELERATORS↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

Angular magnetic field beam improves efficiency in klystrons and traveling wave tubes

Special lens shaping allows variation of focusing strength with radius. Lens can be either converging or diverging depending on charge of particles and direction of angular magnetic field. There is potential use for lens in particle analyzers, electron beam welding systems, microwave tube refocusing systems, and possible display type devices.

Neugebauer, W.↗

Spin-strain interactions under hydrostatic pressure in α-RuCl 3

We investigate the effects of hydrostatic pressure on 𝛼−RuCl 3 , a prototypical material for the Kitaev spin model on a honeycomb lattice with a possible spin-liquid ground state. Using ultrasound measurements at pressures up to 1.16 GPa, we reveal significant modifications of the acoustic properties and the 𝐻−𝑇 phase diagram of this material. Hydrostatic pressure suppresses the three-dimensional magnetic order and induces a dimerization transition at higher pressures. At low pressures, the sound attenuation exhibits a linear temperature dependence, while above 0.28 GPa, it becomes nearly temperature independent, suggesting a shift in the phonon scattering regime dominated by Majorana fermions. These findings provide new insights into spin-strain interactions in Kitaev magnets and deliver a detailed characterization of the 𝐻−𝑇 phase diagram of 𝛼−RuCl 3 under hydrostatic pressure.

Focused ion beam↗

A compact electron gun for time-resolved electron diffraction

A novel compact time-resolved electron diffractometer has been built with the primary goal of studying the ultrafast molecular dynamics of photoexcited gas-phase molecules. Here, we discuss the design of the electron gun, which is triggered by a Ti:Sapphire laser, before detailing a series of calibration experiments relating to the electron-beam properties. As a further test of the apparatus, initial diffraction patterns have been collected for thin, polycrystalline platinum samples, which have been shown to match theoretical patterns. The data collected demonstrate the focusing effects of the magnetic lens on the electron beam, and how this relates to the spatial resolution of the diffraction pattern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Field Mapping of a 2.5 T Fixed-Field HTS Gantry Magnet for Proton Therapy

We present results from testing a high-temperature superconducting (HTS) magnet prototype for proton therapy. This magnet is specifically designed for a novel rotating gantry capable of delivering the entire proton beam energy range (70225 MeV) while maintaining a fixed magnetic field in the superconducting magnets. The gantry layout simplifies the magnet design, enabling the use of straight, flat racetrack Bi-2223 (DI-BSCCO) coil technology and operation at higher temperatures (1015 K). The magnet has a non-linear field distribution for bending and focusing the proton beams. To validate this feature, we developed a system for measuring the magnetic field distribution in the magnet aperture. We present the design of this hall probe array and experimental results from two different magnet tests at 4.2 K in a liquid helium bath. These results are compared with the simulated field distribution and discussed in the context of the required field quality for the application.

Mosat, M↗

A millimeter-wave tunneLadder TWT

A millimeter wave traveling wave tube was developed using a dispersive, high impedance forward interaction structure based on a ladder, with non-space harmonic interaction, for a tube with high gain per unit length and high efficiency. The TunneLadder interaction structure combines ladder properties modified to accommodate Pierce gun beam optics in a radially magnetized permanent magnet focusing structure. The development involved the fabrication of chemically milled, shaped ladders diffusion brazed to diamond cubes which are in turn active-diffusion brazed to each ridge of a doubly ridged waveguide. Cold test data are presented, representing the omega-beta and impedance characteristics of the modified ladder circuit. These results were used in small and large signal computer programs to predict TWT gain and efficiency. Actual data from tested tubes verify the predicted performance while providing broader bandwidth than expected.

Jacquez, A.↗

Development of a 39.5 GHz Karp traveling wave tube for use in space

A millimeter-wave TWT was developed using a dispersive, high-impedance forward wave interaction structure based on a ladder, with non-space-harmonic interaction, for a tube with high gain per inch and high efficiency. The 'Tunneladder' interaction structure combines ladder properties modified to accommodate Pierce gun beam optics on a radially magnetized PM focusing structure. The development involved the fabrication of chemically milled, shaped ladders diffusion brazed to each ridge of a double ridged waveguide. Cold-test data are presented, representing the omega-Beta and impedance characteristics of the modified ladder circuit These results were used in small and large-signal computer programs to predict TWT gain and efficiency. A laboratory model tube was designed and fabricated, including all major subassemblies.

Jacquez, A.↗

A millimeter-wave tunneladder TWT

A millimeter-wave traveling wave tube (TWT) was developed using a dispersive, high-impedance forward wave interaction structure based on a ladder, with non-space-harmonic interaction, for a tube with high gain per inch and high efficiency. The 'TunneLadder' interaction structure combines ladder properties modified to accommodate Pierce gun beam optics in a radially magnetized PM focusing structure. The development involved the fabrication of chemically milled, shaped ladders diffusion brazed to diamond cubes which are in turn active diffusion brazed to each ridge of a doubly ridged waveguide. Cold-test data, representing the (omega)(beta) and and impedance characteristics of the modified ladder circuit, were used in small and large-signal computer programs to predict TWT gain and efficiency. The structural design emphasizes ruggedness and reliability. Actual data from tested tubes verify the predicted performance while providing broader bandwidth than expected.

Wilson, D.↗

Investigation of Fully Three-Dimensional Helical RF Field Effects on TWT Beam/Circuit Interaction

A fully three-dimensional (3D), time-dependent, helical traveling wave-tube (TWT) interaction model has been developed using the electromagnetic particle-in-cell (PIC) code MAFIA. The model includes a short section of helical slow-wave circuit with excitation fed by RF input/output couplers, and electron beam contained by periodic permanent magnet (PPM) focusing. All components of the model are simulated in three dimensions allowing the effects of the fully 3D helical fields on RF circuit/beam interaction to be investigated for the first time. The development of the interaction model is presented, and predicted TWT performance using 2.5D and 3D models is compared to investigate the effect of conventional approximations used in TWT analyses.

Kory, Carol L.↗

Improving the Fermilab Booster Notching Efficiency, Beam Losses and Radiation Levels

A fast vertical 1.08-m long kicker (notcher) located in the Fermilab Booster Long-05 straight section is currently used to remove 3 out of 84 circulating bunches after injection to generate an abort gap. With the maximum magnetic field of 72.5 Gauss, it removes only 87% of the 3-bunch intensity at 400 MeV, with 75% loss on pole tips of the focusing Booster magnets, 11% on the Long-06 collimators, and 1% in the rest of the ring. We propose to improve the notching efficiency and reduce beam loss in the Booster by using three horizontal kickers in the Long-12 section. STRUCT calculations show that using horizontal notchers, one can remove up to 96% of the 3-bunch intensity at 400-700 MeV, directing 95% of it to a new beam dump at the Long-13 section. This fully decouples notching and collimation. The beam dump absorbs most of the impinging proton energy in its jaws. The latter are encapsulated into an appropriate radiation shielding that reduces impact on the machine components, personnel and environment to the tolerable levels. MARS simulations show that corresponding prompt and residual radiation levels can be reduced ten times compared to the current ones.

43 PARTICLE ACCELERATORS↗

Final-focus Superconducting Magnets for SuperKEKB

The SuperKEKB collider aims at 40 times higher luminosity than that achieved at KEKB, based on the nano-beam scheme. The vertical beta function at the interaction point will be squeezed to 300μmeter. Final-focus superconducting magnet system which consists of eight main quadrupole magnets, 43 corrector windings, and compensation solenoids is a key component to achieve high luminosity. This invited talk presents the construction and commissioning of the final-focus magnet system.

43 PARTICLE ACCELERATORS↗

Gantry for medical particle therapy facility

A particle therapy gantry for delivering a particle beam to a patient includes a beam tube having a curvature defining a particle beam path and a plurality of fixed field magnets sequentially arranged along the beam tube for guiding the particle beam along the particle path. In a method for delivering a particle beam to a patient through a gantry, a particle beam is guided by a plurality of fixed field magnets sequentially arranged along a beam tube of the gantry and the beam is alternately focused and defocused with alternately arranged focusing and defocusing fixed field magnets.

60 APPLIED LIFE SCIENCES↗